20
5/10/2010 1 GlueX Col meeting, A. Gasparian 1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline HyCal calorimeter PbW0 4 detectors Resolutions Transition region

5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline HyCal calorimeter

Embed Size (px)

Citation preview

Page 1: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

5/10/2010 1GlueX Col meeting, A. Gasparian

1

The PrimEx HyCal Calorimeter

A. GasparianNC A&T State University, Greensboro, NC

Outline

HyCal calorimeter PbW04 detectors Resolutions Transition region

Page 2: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

5/10/2010 2

The PrimEx HyCal Calorimeter

1152 PbWO4 individual crystal detectors (70 x 70 cm2 insertion)

GlueX Col meeting, A. Gasparian

576 Lead Glass detectors

Page 3: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

5/10/2010 3

The HYCAL Calorimeter (Crystal part)

GlueX Col meeting, A. Gasparian

Page 4: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

Calor-2004, March 30 A. Gasparian 4

PbWO4 Crystal Dimensions

Geometrical size:

20.5 x 20.5 x 180.0 mm3

Tolerances (mm):

20.5 + 0.0 - 0.1 180.0 + 0.3 -0.0 Specified

Measured

Page 5: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

Calor-2004, March 30 A. Gasparian 5

PbWO4: Optical Properties

Page 6: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

04/19/23 6

PbWO4: Position Resolution vs. Energy

Detector characteristics and resolution have been done in different ways: with secondary electron beam (PS in Hall B); with low intensity tagged photon beam (Hall B tagger)

σ =2.7 mm @ 1. GeV

Page 7: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

04/19/23 7

PbWO4: Position Resolution vs. impact coordinate

Page 8: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

04/19/23 8

Lead-Glass: Position Resolutionvs. Energy

σ =5.6 mm @ 1. GeV

Page 9: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

04/19/23 9

PbWO4: Energy Resolution vs. Energy

σ =2.45% @ 1. GeV

Page 10: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

04/19/23 10

Lead-Glass: Energy Resolution vs. Energy

σ =5.7% @ 1. GeV

Page 11: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

04/19/23 11

Transition Region: PbWO4 - Lead-Glass

Page 12: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

04/19/23 12

Transition Region: PbWO4 - Lead-GlassReconstructed Coordinate

Page 13: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

04/19/23 13

Transition Region: PbWO4 - Lead-GlassReconstructed Coordinate (Eγ = 5.2 GeV)

Page 14: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

04/19/23 14

Transition Region: PbWO4 - Lead-GlassPosition Resolution (Eγ = 5.2 GeV)

Page 15: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

04/19/23 15

Transition Region: PbWO4 - Lead-GlassReconstructed Energy (Eγ = 5.2 GeV)

Page 16: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

04/19/23 16

Transition Region: PbWO4 - Lead-GlassEnergy Resolution (Eγ = 5.2 GeV)

Page 17: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

5/10/2010 17

Sensitivity to Magnetic Field

GlueX Col meeting, A. Gasparian

Possible modifications:

change the G10 housing to sift ion housing and extend it to ~1”

insert optical extension

extend the brass strips (look at different options first)No need to change the optical wrapping

The current design do not have extended µ-metal on photocathode Try to shield the FCAL frame with some µ-metal, if it is all possible

Page 18: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

5/10/2010 18

Summary

The Hybrid Calorimeter concept have been successfully reapproved with the HyCal calorimeter in the PrimEx experiment.

Technical and methodical aspects of the Hybrid calorimeter are well understood and tested. On-site expertise is available.

HyCal is equipped with ~2000 channel power supply (CAEN) unit; Trigger and analog electronics are old.

1152 PbWO4 high resolution, radiation hard crystal detectors are available for future experiments.

HyCal will stay in Hall B up to the end of PrimEx-II experiment.

GlueX Col meeting, A. Gasparian

Page 19: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

5/10/2010 19A. Gasparian GlueX Col meeting, A. Gasparian

19

The End

Page 20: 5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline  HyCal calorimeter

04/19/23 20

Invariant Mass Resolution

PbWO4

onlyPb-Glassonly