2
The Moxtek ® 50kV Monoblock X-ray Source is a small, low power device used for a variety of applications including handheld, portable, and bench top instrumentation. X-ray Sources 50kV Monoblock with MAGNUM ® X-ray Source Datasheet Features Benefits Applications Specifications Tube type: Ambient Temperatureº: Storage Temperatureº: Cooling: HV Insulation Weight: Available Targets: HV Polarity: High Voltage Potential: Beam Current: Maximum Power: Focal Spot Size: Window: Input Power: Focus-to-Object Distance: Standard Warranty: Metal-ceramic -10º to +50º C -25º to +85º C Air Silicone potting ~350g Ag, W, Rh Grounded anode 4 to 50kV 0 to 0.200mA 4 watts Typical ~ 400μm Beryllium, 0.25mm thick 6-12 VDC 2.2mm One year TUB00082 TUB00083 TUB-DATA-1002, Rev B Subject to technical change without notice Small, compact design Close coupling of detector/ source Lightweight Portable, easy to integrate Stable output High precision of measurements, low detection limits Low power consumption Long battery life Low spectral contamination Clean spectrum, high precision of analysis High x-ray output Short sampling time X-ray Imaging Medical R&D, small animal imaging Security Radiographic inspection Materials Characterization and Identification (XRF) Metal and alloy sorting Mining and geology Environmental analysis Lead in paint Regulatory (RoHS/WEEE) Art and archeometry R&D Please contact Moxtek for price and delivery information.

50kV Monoblock with MAGNUM X-ray Source TUB …moxtek.com/.../50kV-Monoblock-with-MAGNUM-X-ray... · The Moxtek® 50kV Monoblock X-ray Source is a small, low power device used for

  • Upload
    tranque

  • View
    228

  • Download
    0

Embed Size (px)

Citation preview

The Moxtek® 50kV Monoblock X-ray Source is a small, low power device used for a variety of applications including handheld, portable, and bench top instrumentation.

X-raySources

50kV Monoblock with MAGNUM® X-ray SourceDatasheet

Features Benefi ts

Applications Specifi cations

Tube type:Ambient Temperatureº:Storage Temperatureº:

Cooling:HV Insulation

Weight:Available Targets:

HV Polarity:High Voltage Potential:

Beam Current:Maximum Power:

Focal Spot Size:Window:

Input Power:Focus-to-Object Distance:

Standard Warranty:

Metal-ceramic-10º to +50º C-25º to +85º CAirSilicone potting~350gAg, W, RhGrounded anode4 to 50kV0 to 0.200mA4 wattsTypical ~ 400µmBeryllium, 0.25mm thick6-12 VDC2.2mmOne year

TUB00082

TUB00083

TUB-DATA-1002, Rev BSubject to technical change without notice

Small, compact design Close coupling of detector/ sourceLightweight Portable, easy to integrateStable output High precision of measurements, low detection

limitsLow power consumption Long battery lifeLow spectral contamination Clean spectrum, high precision of analysisHigh x-ray output Short sampling time

X-ray Imaging■ Medical R&D, small animal

imaging■ Security■ Radiographic inspection

Materials Characterization and Identifi cation (XRF)

■ Metal and alloy sorting■ Mining and geology■ Environmental analysis■ Lead in paint■ Regulatory (RoHS/WEEE)■ Art and archeometry■ R&D

Please contact Moxtek for price and delivery information.

TUB00082 Mechanical Drawing

TUB-DATA-1002, Rev BSubject to technical change without notice

452 West 1260 North / Orem, UT 84057 Phone 801.225.0930 / Fax 801.221.1121 [email protected]

TUB00083 Mechanical Drawing