501_Datasheet

Embed Size (px)

Citation preview

  • 7/29/2019 501_Datasheet

    1/1

    Five Test Voltages: 50 , 100 , 250 , 500 , and 10 00 VDC Voltage Measurement to 1 000 V AC/ DC Test Probe Signal Lamp I llum inates Work Ar ea and In dicates Pass/ Fail of

    Insulation Resistance Battery Powered with Battery Test and Battery Charge Indicator Rugged Tester Design for Industrial Applications with Leatherette Carrying Case

    501 Insulation Tester

    The model 5 01 can be u sed for general purpose insulation tests that r equire voltagesfrom 50V to 1000V only.The Instru ment i s equipped wi th AC and DC measuring ran ges up to 1 00 0V. This is

    advantageous for testing for the absence of voltage and the discharge of capacitivedevices under test.The 50 1 f eatures a quick testing signal lamp w ithin the test probe that illuminates thework area. The signal lamp can also be used for quick Pass/ Fail evaluations ofinsulation resistances. Minim um va lues for in sulation resistances are present if thelamp lights up.Comes equipped with built-in test probes, an alligator clip, a leatherette carrying caseand batteries.

    Ordering InformationACCESSORIES Catalog No.501 Insulation Tester, 1000 V 12501

    INSULATION RESISTANCE

    DIRECT AND ALTERNATING CURRENT

    (1) Referring to scale length

    REFERENCE CONDI TION SAmbient Temperature:73F (23C) 4F (2C)Relative Humidity:45 to 55%M easurement M agnitude Frequency:45-65 Hz (voltage measurements)Line Voltage W aveform:Sine, deviation between effective and rectifieBattery Voltage:9V .5VOperat ing Position:Horizontal

    ELECTROM AGNETIC COM PATIBILITY EM CInterference Emission:

    EN 50081-1: 1992Interference Immunity:EN 50082-1: 1992

    ELECTRICAL SAFETYDesigned to IEC 10 10 -1Protection Class:IITest Voltage: 5.55KvOver voltage Classification:IIPollution Degree:2Protection:Housing IP52

    AM BIENT CONDITIONSOperat ing Temp. Ra nge:32F (0C) to 104F (40C)Storage Temp. Range:-4F (-20C) to 140F (60C) (without batteries)

    Relative Humidity:Max. 45-55%, condensation must be avoidedM ECHAN ICAL DESIGNDimensions:W 6.50 (165mm) xD 4.33 (110mm) xH 4.92 (125mm)Weight:3.5 lbs. (1.6kg) (with batteries)

    POW ER SUPPLYStandard or Storage Battery:6 ea. 1.5V D size batteriesWorking Range:7V to 10VBattery Service Life:Number of possible measurements with 1 set of batteries (with lamp in test prod switched off): at least 3,000 measinsulation resistance of 1M(Nominal Voltage of1000 V, 5 sec. Measuremswitched off for 25 sec. etc.)

    Specifications

    (1) Switching Accuracy

    M easuring Ranges

    M easuringR ange O pen- Cir cuit Vo lt age Uo Internal Resistance Ri

    Lamp in Test Prod1)Lights for Resistance

    0 5 0K20 K 1M

    200K 20M60 V

    30 K10 K40 K

    > 100K

    0 1 00 K40 K 2M

    400K 40M120V

    60 K20 K80 K

    > 200K

    0 2 50 K100K 5M1M 1 00 M

    300V150K50 K200K

    > 500K

    0 5 00 K200K 10M2M 2 00 M

    600V300K100K400K

    > 1M

    0 1M400K 20M4M 4 00 K

    1200V600K200K800K

    > 2M

    0 4K 9V

    M easuringR ange Fr equency

    InternalResistance

    M aximamOverload Intrinsic Error (1)

    0 to 1000VAC/ DC

    0 or 40 to 200Hz 900K 1200V AC/ DCContinuous

    2.5%

    rev_1 11/2/04