Five Test Voltages: 50 , 100 , 250 , 500 , and 10 00 VDC Voltage Measurement to 1 000 V AC/ DC Test Probe Signal Lamp I llum inates Work Ar ea and In dicates Pass/ Fail of
Insulation Resistance Battery Powered with Battery Test and Battery Charge Indicator Rugged Tester Design for Industrial Applications with Leatherette Carrying Case
501 Insulation Tester
The model 5 01 can be u sed for general purpose insulation tests that r equire voltagesfrom 50V to 1000V only.The Instru ment i s equipped wi th AC and DC measuring ran ges up to 1 00 0V. This is
advantageous for testing for the absence of voltage and the discharge of capacitivedevices under test.The 50 1 f eatures a quick testing signal lamp w ithin the test probe that illuminates thework area. The signal lamp can also be used for quick Pass/ Fail evaluations ofinsulation resistances. Minim um va lues for in sulation resistances are present if thelamp lights up.Comes equipped with built-in test probes, an alligator clip, a leatherette carrying caseand batteries.
Ordering InformationACCESSORIES Catalog No.501 Insulation Tester, 1000 V 12501
INSULATION RESISTANCE
DIRECT AND ALTERNATING CURRENT
(1) Referring to scale length
REFERENCE CONDI TION SAmbient Temperature:73F (23C) 4F (2C)Relative Humidity:45 to 55%M easurement M agnitude Frequency:45-65 Hz (voltage measurements)Line Voltage W aveform:Sine, deviation between effective and rectifieBattery Voltage:9V .5VOperat ing Position:Horizontal
ELECTROM AGNETIC COM PATIBILITY EM CInterference Emission:
EN 50081-1: 1992Interference Immunity:EN 50082-1: 1992
ELECTRICAL SAFETYDesigned to IEC 10 10 -1Protection Class:IITest Voltage: 5.55KvOver voltage Classification:IIPollution Degree:2Protection:Housing IP52
AM BIENT CONDITIONSOperat ing Temp. Ra nge:32F (0C) to 104F (40C)Storage Temp. Range:-4F (-20C) to 140F (60C) (without batteries)
Relative Humidity:Max. 45-55%, condensation must be avoidedM ECHAN ICAL DESIGNDimensions:W 6.50 (165mm) xD 4.33 (110mm) xH 4.92 (125mm)Weight:3.5 lbs. (1.6kg) (with batteries)
POW ER SUPPLYStandard or Storage Battery:6 ea. 1.5V D size batteriesWorking Range:7V to 10VBattery Service Life:Number of possible measurements with 1 set of batteries (with lamp in test prod switched off): at least 3,000 measinsulation resistance of 1M(Nominal Voltage of1000 V, 5 sec. Measuremswitched off for 25 sec. etc.)
Specifications
(1) Switching Accuracy
M easuring Ranges
M easuringR ange O pen- Cir cuit Vo lt age Uo Internal Resistance Ri
Lamp in Test Prod1)Lights for Resistance
0 5 0K20 K 1M
200K 20M60 V
30 K10 K40 K
> 100K
0 1 00 K40 K 2M
400K 40M120V
60 K20 K80 K
> 200K
0 2 50 K100K 5M1M 1 00 M
300V150K50 K200K
> 500K
0 5 00 K200K 10M2M 2 00 M
600V300K100K400K
> 1M
0 1M400K 20M4M 4 00 K
1200V600K200K800K
> 2M
0 4K 9V
M easuringR ange Fr equency
InternalResistance
M aximamOverload Intrinsic Error (1)
0 to 1000VAC/ DC
0 or 40 to 200Hz 900K 1200V AC/ DCContinuous
2.5%