Upload
pravinmevada
View
533
Download
69
Embed Size (px)
DESCRIPTION
H
Citation preview
Simulator STVDST-01 To verify TV and Monitor flyback transformers (diode split) that work at 15 KHz.
Features
Real simulation of the horizontal deflection stage at low voltage (see oscilloscope).
Deferred measure to the MAT. Display by oscilloscope of the
flyback pulse of any winding. Operation of the high voltage
winding and its diodes as in the TV.
Breakdown warning light. Digital coding of anomaly type. You can verify any flyback
eventhough we have no HR equivalent.
Operation
Analysis of DST transformers without the television or monitor.
Initial diagnosis without removing the transformer from the TV or monitor.
DST transformer measurements taken without applying high voltage.
Time savings in TV or monitor repairs.
Compact and functional equipment.
Technical characteristics
How to verify defective flyback?
1. Connect primary transformer feed terminal to the simulator red cable (+), yellow cable (collector).
2. Connect ABL terminal and ground pin of the flyback to the black ground cable from the simulator.
3. Connect transformer EHT silicon cap to the simulator.
4. Connect the simulator to the AC/DC adaptors.
Test results:
Good Flyback: The High Voltage will be shown in the display.
Defective Flyback: The red led lights and the defect code is shown in the first display digit.