2
4. PC SOFTWARE eXport 1. Launch eXport soſtware. 2. Create a new project by going to [File] [New Project] or click 3. To import saved results, go to • [Import] [Device] for direct USB connecon or click • [Import] [USB Flash Drive] for imporng from USB flash drives or click • [Import] [From PC] for imporng from local hard drives 4. To export saved results, go to • [Export] [PDF] to export selected test result(s) in summary or detail. • [Export] [CSV] to export selected test result(s) in summary or detail. 5. To view detailed results, double click on the cable label and a new window with comprehensive results and plots will be opened. LIST BASED TESTING To load label list 1. Insert USB flash drive to the LOCAL unit. 2. Select [Label List] and select the label list you want to import. 3. Select [Copy Label Files]. 4. Press the [SETUP] buon [Project Sengs] [Label Source] 5. Select [List Based Tesng] and select the label that has just been imported. 6. Press the [AUTOTEST] buon to view list and select label for test. 7. A PASS or FAIL result will be indicated aſter every test. Encircled Flux Compliant Mul-Mode Adapter Kit KIT CONTENTS Mul-Mode Adapter Kit (WX_AD_EF_MM2) A pair of Mul-Mode adapters with source wavelength of 850/1300nm A pair of modally transparent 50/125um FC-SC simplex test cords (2m) A pair of 50/125um SC-SC simplex test cords (2m) Single SC-SC coupler for seng up to 2 jumpers reference Single one-click SC cleaning kit OPTIONAL CORD KITS LC Connector Cord Kit ST Connector Cord Kit Cable Label ˅ Device USB Flash Drive From PC From Cloud OTDR Other Format File Import Export Sengs Tools Cloud Help X eXport Cable Label ˅ PDF CSV File Import Export Sengs Tools Cloud Help X eXport Cable Label ˅ New Project Open Project Save Project Close Project Recent Exit File Import Export Sengs Tools Cloud Help X eXport WireXpert4500_FiberMMEF_IT_EN_QSG_201811 Opcal Loss Test Kit Quick Start Guide itnetworks.soſting.com/WX4500 01-11-2018 Firmware Export Import Licensing Upgrade Firmware 8.0 #1039 Test Results Custom Limits Label List Ac�vate License(s) 01-11-2018 List Based Tes�ng: Label Source Files Copy Label Files Demo1.lbt Demo2.lbt Select/Unselect Label Files 01-11-2018 List Based Tes�ng: Label Source Files Demo1.lbt Demo2.lbt 1 File(s) Copied 01-11-2018 Cable Label Source None Simple Cable Label Template Label List Based Tes�ng Free Form 01-11-2018 LBT Demo1 01-11-2018 Project Se�ngs Site Unspecified Operator Unspecified Label Source Simple Label AutoSave I O Next Label A-2 Test Project The product shall only be used within the condions listed in the main manual and datasheet. Please consult the main manual and datasheet for more details. ! ©2019 Soſting IT Networks GmbH. In line with our policy of connuous improvement and feature enhancement, product specificaons are subject to change without noce. All rights reserved. Soſting and the Soſting Logo are trademarks or registered trademarks of Soſting AG. All other trademarks, registered or unregistered, are sole property of their respecve owners. To get in touch with us, please use our contact form on itnetworks.soſting.com

4. PC SOFTWARE eXport LIST BASED TESTING · Next Label A-2 200.0 m A-1 TIA-568.3 ... Clean the adapters and test cords with the cleaner provided in the kit. 2. Depending on the reference

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 4. PC SOFTWARE eXport LIST BASED TESTING · Next Label A-2 200.0 m A-1 TIA-568.3 ... Clean the adapters and test cords with the cleaner provided in the kit. 2. Depending on the reference

4. PC SOFTWARE eXport1. Launch eXport software.

2. Create a new project by going to [File] → [New Project] or click

3. To import saved results, go to

• [Import] → [Device] for direct USB connection or click • [Import] → [USB Flash Drive] for importing from USB flash drives

or click • [Import] → [From PC] for importing from local hard drives

4. To export saved results, go to

• [Export] → [PDF] to export selected test result(s) in summary or detail.

• [Export] → [CSV] to export selected test result(s) in summary or detail.

5. To view detailed results, double click on the cable label and a new window with comprehensive results and plots will be opened.

LIST BASED TESTINGTo load label list

1. Insert USB flash drive to the LOCAL unit.

2. Select [Label List] and select the label list you want to import.

3. Select [Copy Label Files].

4. Press the [SETUP] button → [Project Settings] → [Label Source]

5. Select [List Based Testing] and select the label that has just been imported.

6. Press the [AUTOTEST] button to view list and select label for test.

7. A PASS or FAIL result will be indicated after every test.

Encircled Flux CompliantMulti-Mode Adapter Kit

KIT CONTENTS

Multi-Mode Adapter Kit (WX_AD_EF_MM2)• A pair of Multi-Mode adapters with source wavelength of 850/1300nm• A pair of modally transparent 50/125um FC-SC simplex test cords (2m)• A pair of 50/125um SC-SC simplex test cords (2m)• Single SC-SC coupler for setting up to 2 jumpers reference• Single one-click SC cleaning kit

OPTIONAL CORD KITS• LC Connector Cord Kit• ST Connector Cord Kit

Cable Label ˅Device USB Flash Drive From PCFrom Cloud

OTDR

Other Format �

File Import Export Settings Tools Cloud Help

X eXport

Cable Label ˅PDF �

CSV �

File Import Export Settings Tools Cloud Help

X eXport

� Disconnected

Cable Label ˅New ProjectOpen ProjectSave ProjectClose Project

Recent �

Exit

File Import Export Settings Tools Cloud Help

X eXport

WireXpert4500_FiberMMEF_IT_EN_QSG_201811

Optical Loss Test KitQuick Start Guide

itnetworks.softing.com/WX4500

01-11-2018

Firmware

Export

Import

Licensing

Upgrade Firmware 8.0 #1039

Test Results

Custom Limits

Label List

Ac�vate License(s)

01-11-2018

List Based Tes�ng: Label Source Files

Copy Label Files

Demo1.lbt

Demo2.lbt

Select/Unselect Label Files

01-11-2018

List Based Tes�ng: Label Source Files

Copy Label Files

Demo1.lbt

Demo2.lbt

Select/Unselect Label Files

1 File(s) Copied

01-11-2018

Cable Label Source

None

Simple Cable Label

Template Label

List Based Tes�ng

Free Form

01-11-2018

LBT

Demo1

01-11-2018

Project Se�ngs

Site Unspecified

Operator Unspecified

Label Source Simple Label

AutoSave IO

Next Label A-2

Test Project

The product shall only be used within the conditions listed in the main manual and datasheet.Please consult the main manual and datasheet for more details.!

©2019 Softing IT Networks GmbH. In line with our policy of continuous improvement and feature enhancement, product specifications are subject to change without notice. All rights reserved. Softing and the Softing Logo are trademarks or registered trademarks of Softing AG. All other trademarks, registered or unregistered, are sole property of their respective owners.

To get in touch with us, please use our contact form on itnetworks.softing.com

Page 2: 4. PC SOFTWARE eXport LIST BASED TESTING · Next Label A-2 200.0 m A-1 TIA-568.3 ... Clean the adapters and test cords with the cleaner provided in the kit. 2. Depending on the reference

3. AUTOTEST

Connect one end of test cord to WireXpert and other end to link under test on both LOCAL and REMOTE units.

Press the [AUTOTEST] button to perform a certification test.

Viewing an AUTOTEST resultSummary result of the two worst values will be displayed after an AUTOTEST. Select the [View] button to view detailed results.

Saving an AUTOTEST resultTest results can be manually saved by selecting the [Save] button. Only PASS test results will be automatically saved when Autosave is enabled or in List Based Testing mode. FAIL results must be saved manually.

TX TXRX RXLink under test

AUTOTEST

SETUP DATA TOOLS

?

AUTOTEST

SETUP DATA TOOLS

?

> TEST SETTINGS

Go to [Test Settings] → [Test Limits] → [Standard Limits] to select test limit before performing [Set Reference] or [AUTOTEST].

Enter number of connectors and splices only if there are present in link under test. Connectors used during Set Reference and AUTOTEST are automatically included when selecting 1/2/3 Jumper reference.

Selecting Cable Manufacturer

Go to [Test Settings] → [Cable] to specify manufacturer.

Select Generic SMF or Single-mode and Generic MMF for Multi-Mode if manufacturer is unknown.

Select Customized Cable to create cable with custom specifications.

01-11-2018

Test Limit

Standard Limits TIA-568.3

Network Limits

Network Limits Only IO

Length Limit (m) 2000

Cable

Cable: OM3

Manufacturer Generic MMF

Refrac�ve Index 1.493

Modal Bandwidth 500MHz*Km

Test Project

01-11-2018

Standard Limits

TIA

ISO

GB

01-11-2018

TIA-568.3

Indicate the number of connections within the Test Link, excluding the end connectors. The Reference Connections are automatically included as follows:1 Jumper - 22 Jumpers - 13 Jumpers - 0

No of Connections 0

Loss Per Connector (dB) 0.75

No of Splices 0

Loss Per Splice (dB) 0.3

Cable Loss (850nm) 3.5 dB/Km

Cable Loss (1300nm) 1.5 dB/Km

01-11-2018

850nm 0.38 dB

1300nm 0.74 dB

Locator

Next Label A-2

200.0 m

A-1

TIA-568.3

01-11-2018

850nm 0.38 dB

1300nm 0.74 dB

Locator

Next Label A-2

200.0 m

A-1

TIA-568.3

01-11-2018

Enter Label

1q

2w

3e

4r

5t

6y

7u

8i

9o

0p

@a

+s

=d

$f

%g

&h

*j

(k

)l

-z

#x

‘c

;v

:b

/n

\m

12??,

!.

A-1

itnetworks.softing.com/WX4500

1. SETUP> CONFIGURATION

Single Ended / Dual Ended

Select [Single Ended] to conduct loop-back referencing and AUTOTEST with only the LOCAL unit. Select [Dual Ended] to conduct end-to-end referencing and AUTOTEST with both LOCAL and REMOTE units.

1 / 2 / 3 Jumpers Reference Methods

Select 1, 2 or 3 Jumpers reference method depending on requirement. Test cords provided in the kit can perform up to 2 jumpers set reference.Additional test cords are required to perform a 3 jumpers set reference.

Single / Bi-Directional Testing

Select [Single Direction] for test to be conducted only from LOCAL TX to REMOTE RX on Fiber 1 and REMOTE TX to LOCAL RX on Fiber 2 (step 1).Select [Bi-Direction] for test to be conducted from LOCAL to REMOTE and REMOTE back to LOCAL on both Fiber 1 and Fiber 2. Swapping of connections during AUTOTEST is required (step 2).

> PROJECT SETTINGS

SiteCreates folder for AUTOTEST results to be saved into.

OperatorCreates display name for operator handling unit.

Label SourceCreates labeling scheme for saved AUTOTEST result.Select NONE to manually enter AUTOTEST result label when saving.Select LIST BASED TESTING for pre-configured labels created with eXport PC software.

AutoSaveEnable option for WireXpert to auto save every PASS result. Option will be enabled for List Based Testing.

01-11-2018

Configura�on

Single Ended Dual Ended

Single Direc�on

Bi-Direc�on

01-11-2018

Project Se�ngs

Site Unspecified

Operator Unspecified

Label Source Simple Label

AutoSave IO

Next Label A-2

Test Project

2. SET REFERENCE1. Clean the adapters and test cords with the cleaner provided in the kit.

2. Depending on the reference method selected, follow the diagram on WireXpert to set up Set Reference using test cords provided in the kit.

3. Check that the units are connected.

4. Click the [Next] button to set reference.

5. Check the Set Reference values are between -3 and -9 dBm for both Single-mode and Multi-mode.

6. Perform verification test if performing 1 jumper reference method. Refer to User Manual for more information.

Single Mode (SM)

Multi Mode (MM)

Encircled Flux MM (MMEF)

Set Reference -3 to -9dBm -18 to -20dBm

Verification Test 0.2dB 0.1dB