2
Intra-frequency measurement reporting criteria. The triggering of the event-triggered reporting for an intra-frequency measurement. All events concerningintrafrequency measurements are labelled 1x where x is a, b, c…. Event 1a: A Primary CPICH enters the Reporting Range. Event 1b: A Primary CPICH leaves the Reporting Range. Event 1c: A Non-active Primary CPICH becomes better than an active Primary CPICH. Event 1d: Change of best cell. Event 1e: A Primary CPICH becomes better than an absolute threshold. Event 1f: A Primary CPICH becomes worse than an absolute threshold. Inter-frequency measurement reporting criteria. The triggering of the event-triggered reporting for an inter-frequency measurements. All events concerninginterfrequency measurements are labelled 2x where x is a,b,c.. Event 2a: Change of best frequency. Event 2b: The estimated quality of the currently used frequency is below a certain threshold and theestimated quality of a non-used frequency is above a certain threshold. Event 2c: The estimated quality of a non-used frequency is above a certain threshold Event 2d: The estimated quality of the currently used frequency is below a certain threshold Event 2e: The estimated quality of a non-used frequency is below a certain threshold Event 2f: The estimated quality of the currently used frequency is above a certain threshold Inter-system measurement reporting criteria. The triggering of the event-triggered reporting for an inter-system measurement. All events concerninginter-system measurements are labelled 3x where x is a,b,c.. Event 3a: The estimated quality of the currently used UTRAN frequency is below a certain threshold and the estimated quality of the other system is above a certain threshold. Event 3b: The estimated quality of other system is below a certain threshold Event 3c: The estimated quality of other system is above a certain threshold Event 3d: Change of best cell in other system Traffic volume measurement reporting criteria. Contains the measurement reporting criteria information for a traffic volume measurement. Event 4a: RLC buffer payload exceeds an absolute threshold. Event 4b: RLC buffer payload becomes smaller than an absolute threshold. UE internal measurement reporting criteria. The triggering of the event-triggered reporting for a UE internal measurement. All events concerning UEinternal measurements are labelled 6x where x is a, b, c…. In TDD, the events 6a - 6d are measured andreported on timeslot basis. Event 6a: The UE Transmitted Power becomes larger than an absolute threshold Event 6b: The UE Transmitted Power becomes less than an absolute threshold Event 6c:

3G_Events

Embed Size (px)

DESCRIPTION

Event of 3G

Citation preview

Intra-frequency measurement reporting criteria.The triggering ofthe event-triggered reporting for anintra-frequency measurement. All events concerningintrafrequency measurements are labelled 1x where xis a, b, c.Event 1a:A Primary CPICH enters the Reporting Range.Event 1b:A Primary CPICH leaves the Reporting Range.Event 1c:A Non-active Primary CPICH becomes better than an active Primary CPICH.Event 1d:Change of best cell.Event 1e:A Primary CPICH becomes better than anabsolute threshold.Event 1f:A Primary CPICH becomes worse than anabsolute threshold.Inter-frequency measurement reporting criteria.The triggering ofthe event-triggered reporting for aninter-frequency measurements. All eventsconcerninginterfrequency measurements are labelled 2x wherex is a,b,c..Event 2a:Change of best frequency.Event 2b:The estimated quality of the currently usedfrequency is below a certain thresholdandtheestimated quality of a non-used frequency is abovea certain threshold.Event 2c:The estimated quality of anon-used frequency is above acertain thresholdEvent 2d:The estimated quality of the currently usedfrequency is below a certain thresholdEvent 2e:The estimated quality of anon-used frequency is below a certain thresholdEvent 2f:The estimated quality of the currently used frequency isabove a certain thresholdInter-system measurement reporting criteria.The triggering of the event-triggered reporting for an inter-system measurement. All events concerninginter-system measurements are labelled 3x where xis a,b,c..Event 3a:The estimated quality of the currently usedUTRAN frequency is below a certain thresholdandthe estimated quality of the other system isabove a certain threshold.Event 3b:The estimated quality of other system isbelow a certain thresholdEvent 3c:The estimated quality of other system isabove a certain thresholdEvent 3d:Change of best cell inother systemTraffic volume measurement reporting criteria.Contains the measurement reporting criteria information for atraffic volume measurement.Event 4a:RLC buffer payload exceeds an absolute threshold.Event 4b:RLC buffer payload becomes smaller than an absolutethreshold.UE internal measurement reporting criteria.The triggering of the event-triggered reporting for a UEinternal measurement. All events concerning UEinternal measurements are labelled 6x where x is a, b, c. In TDD, the events 6a -6d are measured andreported on timeslot basis.Event 6a:The UE Transmitted Power becomes larger than anabsolute thresholdEvent 6b:The UE Transmitted Power becomes less than anabsolute thresholdEvent 6c:The UE Transmitted Power reaches its minimum valueEvent 6d:The UE Transmitted Power reaches its maximum valueEvent 6e:The UE RSSI reaches theUEs dynamic receiver rangeEvent 6f:The UE Rx-Tx time difference for a RL included in the active set becomes larger than anabsolute thresholdEvent 6g:The UE Rx-Tx time difference for aRL included in the active set becomes lessthan an absolutethreshold