MCR 24 + BMR 80 MCR 24 + SR 130 MCR… BIC, +BMR/SR or MI Heating and domestic hot water by independent calorifier or micro-accumulated MCR 24 : for heating only Condensing MCR 24 : from 6,3 to 25,3 kW, for heating only MCR 24/28 BIC : from 6,3 to 25,1 kW, for heating and domestic hot water preparation by integrated calorifier MCR… MI : from 6,3 to 35,9 kW, for heating and instant domestic hot water production for chimney or forced flue connection All of these boilers are factory fitted with a control panel which can be complemented by a control system offering 2 comfort levels: • Either by room thermostat Or by remote control according to the outside temperature with the possibility of controlling a circuit with mixing valve in addition to a direct circuit Various air/flue gas connection configurations are possible: we offer solutions for connection by horizontal or vertical forced flue, to a chimney, in bi-flow. CONDITIONS OF USE Boiler: Max. operating temperature: 90 °C Max. operating pressure: 3 bars Safety thermostat: 110 °C Power supply: 230 V/50 Hz Protection index: IPX4D BMR 80 and SR 130 DHW calorifier: Max. operating pressure primary and secondary circuits: 10 bars Max. operating temperature primary and secondary circuits: 95 °C HOMOLOGATION B 23P - C 13x - C 33x - C 53 - C 43x - C 63x - C 83x * GAS CATEGORY II 2ESi3P , Classe NOx : 5 *to be adapted according to the country for wich the boilers are intended All natural gases Propane N° d’identification CE : 0063BQ3009 ★★★★ VIVADENS MCR WALL-HUNG GAS CONDENSING BOILERS MCR 24 MCR … MI MCR 24/28 BIC

300010772

Embed Size (px)

Citation preview

Page 1: 300010772

MCR 24 + BMR 80 MCR 24 + SR 130

MCR… BIC, +BMR/SR or MIHeating and domestic hot water by independent calorifier or micro-accumulated

MCR 24 :for heating only

Condensing

MCR 24 : from 6,3 to 25,3 kW, for heating only

MCR 24/28 BIC : from 6,3 to 25,1 kW, for heating

and domestic hot water preparation by integrated

calorifier

MCR… MI : from 6,3 to 35,9 kW, for heating and

instant domestic hot water production for chimney

or forced flue connection

All of these boilers are factory fitted with a control panel which can be complemented by a control system offering 2 comfort levels: • Either by room thermostat• Or by remote control according to the outside temperature with the

possibility of controlling a circuit with mixing valve in addition to a direct circuit

Various air/flue gas connection configurations are possible:we offer solutions for connection by horizontal or vertical forced flue, to a chimney, in bi-flow.

CONDITIONS OF USEBoiler:

Max. operating temperature: 90 °CMax. operating pressure: 3 barsSafety thermostat: 110 °CPower supply: 230 V/50 HzProtection index: IPX4D

BMR 80 and SR 130 DHW calorifier:Max. operating pressure primaryand secondary circuits: 10 barsMax. operating temperature primaryand secondary circuits: 95 °C

HOMOLOGATIONB23P - C13x - C33x - C53 - C43x - C63x - C83x*

GAS CATEGORYII2ESi3P, Classe NOx : 5

*to be adapted according to the country for wich the boilers are intended

All natural gasesPropane

N° d’identification CE :0063BQ3009

★★★★

VIVADENS MCRW A L L - H U N G G A S C O N D E N S I N G B O I L E R S

MCR 24MCR … MI

MCR 24/28 BIC

Page 2: 300010772

2

PRESENTATION

MODELS AVAILABLE

MCR 24, MCR 24/28 BIC and MCR…MI boilers are delivered fully assembled and factory tested. They come ready to operate on natural gases; operation on propane is possible by simple adjustment or by conversion kit (available as optional equipment).MCR 24 boilers are factory fitted with a heating/DHW reversal valve for connection to an independent hot water calorifier: 2 types of optional DHW calorifiers are available:- 80-litre BMR 80 calorifier to be juxtaposed to the right or left of

the boiler: version MCR 24 + BMR 80;- 130-litre SR 130 calorifier to be placed on the floor under the

boiler: version MCR 24 + SR 130.The MCR 24/28 BIC version is particularly compact (900 x 600 x 450 mm) and efficient: DHW production, with *** performance in accordance with EN 13203, is handled by a 40-litre storage calorifier integrated into the boiler, combined with an external plate exchanger with a large exchange surface, a DHW pump and a heating/DHW reversal valve.MCR .. MI boilers are mixed boilers and produce large quantities of domestic hot water (*** classification in accordance with the standard EN 13203) thanks to an oversized plate exchanger and very reactive electronics.

THEY OFFER HIGH LEVELS OF PERFORMANCE:- Efficiency at 40/30°C up to 109 %- Efficiency class ★★★★ CE- NOx < 70 mg/kWh- NOx classification: 5 in accordance with PR EN 15420- Noise level in compliance with NRA (see page 5)

STRONG POINTS

- Particularly compact, light boilers- Perfect adaptation of boiler output to actual needs thanks

to the stainless steel gas burner with complete premixing, modulating from 25 to 100% output, fitted with a silencer on the air intake.

- Stainless steel exchanger with double external envelope in composite material.

- Electronic ignition and ionisation flame check.- Delivered with a mounting frame with prefitted water and gas

valves (including the disconnector), 8-litre expansion vessel (no vessel on MCR 34/39 MI), automatic air vent. The MCR 24/28 BIC is also fitted with the 7-bar DHW safety valve and a flow collector.

- Simple, functional control panel with optional control system offering 2 comfort levels:

• By room thermostat • According to the outside temperature, with the possibility of

also controlling a direct circuit, a circuit with mixing valve by connecting a remote control with specific communication interface and the outside sensor.

- For the various air/flue gas connection options, see page 11.

Boiler ModelUseful output

heating modeat 50/30 °C (kW)

DHW modeat 80/60 °C (kW)

MC

R_Q

0001

For heating only MCR 24 6,3-25,3 –

MC

R_Q

0026

For heating and domestic hot water preparation by integrated 40-litre calorifier

MCR 24/28 BIC 6,3-25,1 6,3-27,4

MC

R_Q

0001

For heating and instant domestic hot waterproduction

MCR 24/28 MIMCR 30/35 MIMCR 34/39 MI

6,3-25,36,6-31,66,8-35,9

6,3-27,46,3-34,36,3-38,2

Page 3: 300010772

3

TECHNICAL SPECIFICATIONS

DESCRIPTION

Stainless steel exchangerwith low inertia and considerable resistance to corrosion with double exterior envelope in composite material used for thermal and phonic insulation

Stainless steel burnerwith total premix modulating from 25 to 100% of the output, with low NOx and CO emissions, with silencer on the air intake

Mounting frame with prefitted plumbing fixtures

Automaticair vent

Heating body and burner

Gas valve unit2-speed circulator pump

Control panel see p. 6

Expansion vessel(8 litres)

40-litre DHW storage calorifier protected by a magnesium anode

7-bar DHW safety valve

Calorifier drainage

Control panel (see p. 6)

3-bar safety valve

Plate exchanger for instant DHW (MCR…MI)

Ionisation and ignition electrodes

Expansion vessel (8 litres – initial pressure 1 bar (no vessel on MCR 34/39 MI)

Air/flue gas connection Ø 60/100 mmwith measuring point

MC

R_Q

0005

MC

R_Q

0011

MCR… MI

MCR 24/28 BIC

Heating body and burner

Air/flue gas connectionwith measuring pointAutomatic

air vent

Heating body and burner

2-speed heating circulator pump

DHWpump

Plate exchanger with large exchange surface

Mounting frame with prefitted water and gas valves (flow collector provided)

3-bar heating safety valve

MC

R_Q

0030

Page 4: 300010772

4

TECHNICAL SPECIFICATIONS

MAIN DIMENSIONS (IN MM AND INCHES)

670584

106

73,3

741

79,8

2642

53

2 3 5 63 44

5 6

9

132,5

328,5

379

400

160

71,5

25

300

26,5

23

17

194

670

584

106

73,3

209

680

880

741

2

10 1110

11

4 6

9

328,5

379

400

71,5

25132,5

300

444160

260Ø 427

Ø 422

176,5

32

73,36

4

2

79,81110

2 10 41162 10 4 11 6

9

972

900

50 65 65 68 66

26,5

600

128

446

21 51 456 51 21

160

584

117

670

584

10673,3

741

2

10 11

4 6

9

328,5

379

400

71,5

25 132,5

300

153110

48

305

590

Ø 570

932

446

2000

160

MCR 24MCR… MI

MCR 24 + BMR 80 (package EE 53) andConnection kit (package HG 29)

MCR 24/28 BIC

MCR 24 + SR 130 (package EE 22) andConnection kit (package HG 30)

MC

R_F0

001

MC

R_F0

002

MC

R_F0

013A

MC

R_F0

004� Heating outlet interior Ø 18 mm

� MCR 24: Primary calorifier outlet interior Ø 16 mm (1)MCR .. MI: Domestic hot water outlet interior Ø 16 mm

� Gas inlet interior Ø 18 mm� MCR 24: Primary calorifier return interior Ø 16 mm (1)

MCR .. MI: Domestic cold water inlet interior Ø 16 mm (1)� Heating return interior Ø 18 mm� Evacuation of combustion products and air inlet pipe

Ø 60/100 mm� Domestic hot water outlet

- MCR 24/28 BIC: Ø 16 mm- MCR 24 + BMR/SR: R 3/4

Domestic cold water inlet- MCR 24/28 BIC : Ø 16 mm- MCR 24 + BMR/SR: R 3/4

(1) if a DHW calorifier is connected

R: threading

* or exterior Ø 15/22 mm, dimensions to be adapted according to the country for which the boilers are intended

} *

Page 5: 300010772

5

TECHNICAL SPECIFICATIONS

SPECIFICATIONS TABLE

Boiler Boiler type: condensingBurner: modulating with complete premixing

Energy used: natural gas or propaneCombustion evacuation: chimney or sealedMin. flow temperature: 15 °C

Min. return temperature: noneRef. CE certificate: 0063BQ3009

Model MCR 24 MCR24/28 BIC

MCR 24 + BMR 80MCR 24 + SR 130

MCR24/28 MI

MCR30/35 MI

MCR34/39 MI

Useful output at 50/30 °C Pn (heating mode) kW 6,3-25,3 6,3-25,1 6,3-25,3 6,3-25,3 6,6-31,6 6,8-35,9Nominal output at 80/60 °C (DHW mode) kW - 27,4 - 27,4 34,3 38,2

100 % Pn at ave. temp. 70 °C % 98,3 98,3 98,3 98,3 98,2 98,0100 % Pn at return temp. 30 °C % 104,4 104,4 104,4 104,4 104,4 104,430 % Pn at return temp. 30 °C % 108,7 108,7 108,7 108,7 109,7 110,5

Nominal water output at Pn, Δt = 20 K m3/h 1,03 0,93 1,03 1,03 1,29 1,47Loss when not in use at Δt = 30 K W 30 nc. 30 30 29 28Auxiliary electrical power at Pn (without circul.) W 25 25 25 25 25 45Circulator pump output W 90 90 90 90 125 135Useful output at 80/60 °C - min/max kW 5,5-23,6 5,5-23,1 5,5-23,6 5,5-23,6 5,7-29,5 5,9-33,3Manometric height avail. heating circuit mbar > 200 > 200 > 200 > 200 > 200 > 200Water capacity l 1,7 1,8 1,7 1,8 2,0 2,2Gas flow at Pn - gas H/L m3/h 2,5/3 2,5/3 2,5/3 2,5/3 3,2/3,7 3,6/4,2(15°C, 1013 mbar) - propane kg/h 1,9 1,9 1,9 1,9 2,3 2,6Average flue gas temperature at 80/60 °C °C 78 78 78 78 74 71,5Min/max mass flue gas output kg/h 10/47 10/48 10/47 10/47 10/59 10/62Pressure available at the boiler outlet Pa 50 100 50 100 100 140Total weighted min./max. noise output in accordance with NF EN ISO 3741 dB (A) 43,1-49,3 nc. 43,1-49,3 43,1-49,3 45,0-47,9 44,1-49,5

Net weight kg 29 61 97/105 30,5 32 31,5

Specifications domestic hot water

Model MCR 24/28 BIC MCR 24 + BMR 80 MCR 24 + SR 130 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MIExchanged power kW 27,4 22,6 22,6 27,4 34,3 38,2Flow over 10 min at Δt = 30 K l/10 min 180 165 200 - - -Flow over 10 min at Δt = 35 K l/h 670 555 555 - - -Spec. output at Δt = 30 K (1) l/min 18,0 16,5 20,0 14,0 17,0 19,0Min. pressure for a flow of 11 l/min bar - - - 0,4 0,4 0,4DHW losses through the outer casing at Δt = 45 K W - 73 - - -Aux. elec. output in DHW mode W 175 115 115 115 150 180Cooling constant kWh/24hl.K. - - 0,27 - - -Domestic performance at room temp. 20 °C, cold water temp. 10 °C, primary hot water temp. 85 °C(1) in accordance with EN 13203-1 for MCR 24 + BMR/SR and MCR 24/28 BIC

in accordance with EN 625 for MCR … MI

Effi ciency in % oflow calorific powerat load …% Pn and water temp. …°C

Page 6: 300010772

6

CONTROL PANEL

CONTROL PANEL ON MCR BOILERS

CONTROL PANEL OPTIONS

MCR boilers are fitted with a very simple control panel. This allows the continuous adaptation of “heating” and “DHW” output to needs. It incorporates functions for antifreeze protection

and cleaning the circulator pump every 25 hours and a troubleshooting assistance system with alarm code display.

“Menu” keyManometer

On/Off switch

Large LCD display

“Sweep” key

“Space” or “reset” key Maintenance key or validation key

Heating temp. adjustment key or “–” key DHW temp. adjustment key or “+” key

MC

R_Q

0004

Programmable wire-controlled room thermostat - Package AD 137Programmable wireless room thermostat - Package AD 200Non-programmable room thermostat - Package AD 140

Package AD 140

Package AD 200

The programmable thermostats handle the regulation and weekly programming of heating by activating the burner in accordance with the various operating modes: “Automatic” depending on programming, “Permanent” at a set temperature or “Holidays”. The “wireless” version is delivered

with a receiver box to be affixed to the wall close to the boiler.The non-programmable thermostat is used to regulate the room temperature according to the instruction given by activation of the burner.

8801

Q00

386

66Q

120A

MC

R_Q

0023

Easymatic communicating wire-controlled remote control - Package FM 50Easyradio communicating wireless remote control - Package AD 201To function, these remote controls must be complemented with a boiler/remote control “interface” PCB:Easymatic/Easyradio interface for connecting 1 direct circuit - Package AD 221Easymatic/Easyradio interface for connecting 1 direct circuit + 1 mixer valve circuit - Package AD 222

Package AD 201

Package AD 221

Package AD 222

These remote controls handle the regulation and weekly programming of heating by activating the burner and the circulator pump on the direct circuit or the valve circuit (if one exists) according to several operating modes: “Automatic” according

to programming, “Permanent comfort”, “Reduced permanent”, “Holidays” or “Summer”. Likewise, they handle the regulation and programming of domestic hot water.

8666

Q11

9AM

CR_

Q00

22

Outside sensor - Package AD 225The outside sensor can be used alone or in combination with room thermostats or communicating remote controls for heating regulation dependent on the outside temperature.

It is essential if using an installation with a mixing valve circuit.

MC

R_Q

0021

Domestic hot water sensor - Package AD 226

The domestic hot water sensor is used to apply priority regulation to DHW production by an independent calorifier. It is necessary, particularly

if connecting a BMR 80 or SR 130 calorifier, presented as optional equipment for these boilers.

MC

R_Q

0018

(1) For controlling a valve circuit, the connection of an outside sensor is required, see below.

Page 7: 300010772

7

BOILERS OPTIONS

MC

R_Q

0015

Height adjustment frame - MCR 24 et MCR… MI - Package HG 19- MCR 24/28 BIC - Package HG 75

This frame replaces the mounting frame delivered as standard with MCR boilers in order to make it possible to pass the water and gas connection

pipes behind the boiler (upwards). The plumbing fixtures are taken from the original frame and fitted to the height adjustment frame.

MC

X_F0

005

Connecting pipe kit Ø 16/18 or 15/22 mm for height adjustment frame* - Package HG 20 or HG 32This kit comprises the 5 water and gas connecting pipes to be connected to the plumbing fixtures on the MCR mounting frames to be passed behind the

top rear section of the boiler through the height adjustment frame (option above).

MC

R_Q

0006

Mounting frame with disconnector for MCR 24 - Package HG 27Mounting frame with disconnector for MCR .. MI - Package HG 33

These mounting frames are delivered as standard with the boilers concerned. However, they can be delivered in a separate package to be prefitted

and thus enable the fitter to make all the hydraulic connections in advance and install the boiler only at the last minute.

MC

R_Q

0020

Pipe cover - MCR 24 and MCR… MI - Package HG 21- MCR 24/28 BIC - Package HG 76

Provides a neat finish underneath the boiler.

MCR 24 andMCR… MI

MCR 24/28 BIC

MC

R_Q

0029

8531

Q05

0

DHW expansion vessel for MCR 24/28 BIC - Package HG 77This prevents water losses due to expansion during reheating of the domestic hot water calorifier.

Capacity: 2 litres

Condensates neutralisation calorifier - Package HC 33Wall bracket for neutralisation calorifier - Package HC 34Granule refill for neutralisation - Package HC 35

The materials used for the condensates flow pipes must be appropriate; otherwise the condensates must be neutralised. A regular check of the neutralisation system and particularly the

effectiveness of the granules by measuring the pH is necessary. If need be, the granules should be replaced.

Package HC 33

Package HC 34

8531

Q02

785

31Q

028A

MC

X_F0

010

Flow collector - Package HG 28*Used to collect the run-off from the condensates flow siphon, the safety valve and the disconnector.

*options : to be adapted according to the country for wich the boilers are intended

Page 8: 300010772

8

BOILER OPTIONS

INFORMATION REQUIRED FOR INSTALLATION

Propane conversion kit - Package HG 44(for all boilers except MCR 34/39 MI)Propane burner for MCR 34/39 MI - Package HG 31

To run the MCR 34/39 MI on propane, it is necessary to replace the burner fitted to the boiler with this specific burner.

For the other boilers, use the propane conversion kit or change the boiler settings.

BMR 80 domestic hot water calorifier - Package EE 53BMR 80-MCR 24 connection kit - Package HG 29SR 130 domestic hot water calorifier - Package EE 22SR 130 - MCR 24 connection kit - Package HG 30BMR 80 and SR 130 domestic hot water calorifiers are high performance calorifiers. They are protected inside by food quality standard high quartz content vitrified enamel and by a magnesium anode.The specifications of these calorifiers combined with MCR boilers are given on pages 2 and 3.

The boiler/water calorifier connection kits available include rigid and/or flexible connection pipes between the boiler and the calorifier.

MC

R_Q

0010

MC

R_Q

0016

BMR 80 HG 29

SR 130

8666

Q04

3

HG 30

8666

Q04

3

50 min.

50 min.

min. 250

min. 250

670

400

100

min

i

300

MC

R_F0

005

LOCATION

MCR condensing boilers must be installed in premises protected from frost, which can also be ventilated. The IPX4D protection index enables them to be installed in kitchens and bathrooms, excluding protection volumes 1 and 2, however.In order to ensure adequate accessibility around the boiler, we recommend that you respect the minimum dimensions given opposite.

VentilationThis must comply with prevailing regulations.

GAS CONNECTION AND ELECTRICAL CONNECTION

Comply with prevailing national or even local instructions and regulations.

Page 9: 300010772

9

INFORMATION REQUIRED FOR INSTALLATION

HYDRAULIC CONNECTIONSImportant: The principle of a condensing boiler is to recycle the energy contained in the water vapour in the combustion gases (latent vaporisation heat). Consequently, to achieve an annual operating efficiency in the order of 109%, it is necessary to size the heating surfaces in such a way as to obtain low return temperatures, below the dew point (e.g. underfloor heating, low temperature radiators, etc.) during the entire heating period.

MCR boilers must only be used in closed-circuit heating installations, previously cleaned to eliminate residues and deposits caused by commissioning the installation. Furthermore, it is important to protect central heating installations against the risk of corrosion, scaling and microbiological growth: the water treatment products used must comply with regulations.

Condensates dischargeThe siphon provided must be connected to the waste water discharge system. The connection must be removable and the flow of condensates visible. The connections and pipes must be in corrosion-resistant material.

An optional condensates neutralisation system is available (package HC 33 see page 7).

STANDARD INSTALLATION DIAGRAMSThe examples presented below cannot cover the full range of installation scenarios which may be encountered. Their purpose is to draw the attention to the basic rules to be followed. A certain number of control and safety devices (some of which are already integrated as standard in MCR boilers) are represented but it is ultimately up to installers, experts, consultant engineers and design departments to take the final decision on the safety and control devices to be used in the boiler room according to its specificities. In all cases, it

is necessary to abide by the codes of practice and prevailing regulations.

Attention: For the connection of domestic hot water, a sleeve made of steel, cast iron or any other insulating material must be interposed between the hot water outlet and these pipes to prevent any corrosion to the connections, if the distribution pipes are made of copper.

MCR 24, MCR 24/28 MI AND MCR 24/28 BIC :(with Grundfos UPR 15-60 type pump)

ΔT 20 °C 18 kW

Flow rate in l/h

Man

om

etr

ic h

eig

ht

in m

bar

MCR 30/35 MI, MCR 34/39 MI :(with Grundfos UPR 15-70 type pump)

ΔT 20 °C 28 kW

Flow rate in l/h

Man

om

etr

ic h

eig

ht

in m

bar

MC

R_F0

009

Manometric height of the heating circulator pump fitted to the MCR

Page 10: 300010772

10

STANDARD INSTALLATION DIAGRAMS

MCR 24 + BMR 80 with 1 direct circuit + 1 domestic hot water circuit, controlled by a wire-controlled programmable room thermostat + outside sensor

MCR .. MI with 1 direct circuit + 1 circuit with mixing valve, controlled by an “Easyradio” communicating wireless remote control + specific interface and outside sensor

230V

50Hz

230V

50Hz

27

32

9

9

Horloge

externe

9 2928

30

33

68

51

64

8

AD 137

27

Thermostatd'ambiance

filaire

21

Commande à distance communicante Easyradio

230V

50Hz

BUS

+

AD 201

9 9 9

64

1

1a 2a2b 1b

2

27

65

11b11b

10

°C °C °C °C

23

44

8

72

4

3

51

2928

9

68 27

AD 222

21

MC

R_F0

007

MC

R_F0

006

MCR 24/28 BIC with 1 direct “underfloor heating” circuit, controlled by a wireless room thermostat

MCR 24/28 BIC with 1 “radiator” circuit, controlled by a programmable wire connection room thermostat + outside sensor

1 Heating outlet 2 Heating return 3 3-bar heating safety valve1a Heating outlet direct circuit1b Heating outlet valve circuit2a Heating return direct circuit2b Heating return valve circuit8 Manual bleed valve9 Isolation valve10 3-way mixing valve11 Heating pump11b Heating pump for circuit with mixing valve16 Expansion vessel

21 Outside sensor23 Outlet temperature sensor after mixing valve

(delivered with PCB package FM 48)26 Domestic water load pump27 Non-return valve28 Domestic cold water inlet29 Pressure reducer30 Sealed safety device calibrated to 7 bars*32 (Optional) DHW loop pump33 DHW temperature sensor44 65 °C limiter thermostat with manual reset for

underfloor heating46 2-position 3-way directional valve50 Disconnector

51 Thermostat valve55 DHW safety valve calibrated and sealed to

7 bars64 Radiator circuit (gentle heat radiators, for

example)65 Low temperature circuit (underfloor heating, for

example)68 Condensates neutralisation system72 Hydraulic bypass75 Domestic water pump

* mandatory, in compliance with safety directives

92928

AD 200

BU

S

21

50Hz

230V

50

11/26

4616

75

355

9

65

44

27

21

50Hz

230V

11/26

4616

75

355

50

AD 137

9

51

64

8

27

92928

MC

R_F0

017A

MC

R_F0

018A

Page 11: 300010772

11

AIR/FLUE GAS CONNECTION

For the use of the air/flue gas connection pipes and the rules on installation, see details of the various configurations in the current

price catalogue.

4 26

2

2

1

5 312

12

12

C33xC33xB23P C33x

C33x

C33xC13x

C53

L1

L1

Lmax = L1+L2

Lmax = L1+L2

Lmax

Lmax

Lmax

Lmax

max max max 1m 1m 1m

Lmax L2

L2 Lmax

Lmax

C43x

C43x

C43x

MC

R_F0

011B

� Configuration C13x : Air/flue gas connection by means of concentric pipes to a horizontal terminal (so-called forced flue)

� Configuration C33x : Air/flue gas connec-tion by means of concentric pipes to a vertical terminal (roof outlet)or

� Air/flue gas connection using concentric pipes in the boiler room and single pipes in the chimney (combustive air with counter current in the chimney)

or� Air/flue gas connection using concentric pipes

in the boiler room and single “flex” pipes in the chimney (combustive air with counter cur-rent in the chimney)

� Configuration C53 : Separate air and flue gas connection using a bi-flow adapter and single pipes (combustive air taken from outside)

� Configuration B23P : Connection to a chimney (combustive air taken from the boiler room)

� Configuration C43x : not to be taken into consideration

Table of maximum air/flue gas pipe lengths admissible according to boiler type

Type of air/flue gas connection Maximum length of the connecting pipes in m

MCR 24 MCR 24/28 MIMCR 24/28 BIC MCR 30/35 MI MCR 34/39 MI

Concentric pipes connected to a horizontalterminal (PPS) C13x Ø 60/100 mm 6 7 4 6

Concentric pipes connected to a vertical terminal (PPS) C33x Ø 80/125 mm 31 32 22 29

Pipes - concentric in the boiler room,- single in the chimney (combustive air with

counter current) (PPS)

C33x

Ø 60/100 mmØ 80 mm 18 23,5 10 12

Ø 80/125 mmØ 80 mm - - 24 25,5

Pipes- concentric in the boiler room,- “flex” in the chimney (combustive air with

counter current) (PPS)

C33xØ 80/125 mmØ 80 mm 15,5 19 18 20

Bi-flow adapter and separate single air/flue gas pipes (combustive air taken from outside) (Alu) C53

Ø 60/100 mmsur 2x80 mm 44 48 30 32,5

In the chimney (rigid or flex) (combustive airtaken from the premises) (PPS) B23P

Ø 80 mm (rigid) 33 37 19 33

Ø 80 mm (flex) 23 27 22,5 24,5

Page 12: 300010772

DE DIETRICH THERMIQUES.A.S. with corporate capital of 22 487 610 d57, rue de la Gare - F - 67580 MertzwillerTél. 03 88 80 27 00 - Fax 03 88 80 27 99www.dedietrich-heating.com

DESCRIPTION

07/0

8 –

3000

1077

2 in

d. A

– 3

47.5

55.5

59 R

.C.S

Stra

sbou

rg –

Doc

umen

t not

bin

ding

. You

can

che

ck it

s va

lidity

on

the

web

site

http

:/w

ww

.ded

ietri

chth

erm

ique

.com

- Pr

inte

d in

Fra

nce

– O

TT-Im

prim

eurs

Was

selo

nne

- 823

44

VIVADENS MCR…WALL-HUNG GAS CONDENSING BOILER FOR CONNECTION TO A CHIMNEY OR A FORCED FLUE

DESCRIPTION

Brand: De DietrichClassification: **** In accordance with the european efficiency directive, NOx classification: 5Model: MCR_____ (MCR 24 for heating only, MCR..MI for

heating and production of instant DHW)MCR 24/28 BIC: (for heating and production of instant DHW

with 40 litres calorifier)Homologation: B23P-C13x-C33x-C53-C43x-C63x-C83x*Gas category: II2Esi3P* Protection index: IPX4D,Power supply: 230 V/50 HzUseful output in heating mode at 40/30 °C: _____kWUseful output in DHW mode at 80/60 °C: _____kWSpecific flow in DHW mode (MCR..MI): _____l/minSpecific flow in DHW mode (MCR 24/28 BIC): 18 l/minMax. operating temperature: 90 °CMax. operating pressure: 3 barSafety thermostat: 110 °CDimensions: 670 x 400 x 300 mmWeight empty: _____kg

- Complies with the requirements of European Directives- Stainless steel exchanger with low inertia and considerable

resistance to corrosion, with double exterior envelope in composite material used for thermal and phonic insulation

- Stainless steel burner with total premix modulating from 25 to 100% of output, with low NOx and CO emissions and a silencer on the air intake

- Control panel facilitating the ongoing adaptation of “heating” and “DHW” output to needs, which can be complemented by various options to regulate heating according to the room or outside temperature

- Fully fitted boilers: 2-speed circulating pump, 8-litre expansion vessel (except MCR 34/39 MI), automatic bleed valves, 3-bar safety valve, mounting frame with prefitted water and gas plumbing fixtures, plate exchanger for instant DHW on MCR..MI or heating/DHW reversal valve on MCR 24, air/flue gas connection in diameters of 60 to 100 mm with measuring outlet

- MCR 24/28 BIC: MCR 24 with 40-litre DHW calorifier integrated into the boiler combined with a plate exchanger, a DHW pump, a heating/DHW reversal valve. Boiler/calorifier connecting pipes and DHW sensor provided

Options for control panel- Programmable wire-controlled room thermostat- Programmable wireless room thermostat- Non programmable room thermostat- Easymatic/Easyradio interface for connecting 1 direct circuit- Easymatic/Easyradio interface for connecting 1 direct circuit +

1 mixer valve circuit- Outside sensor- Domestic hot water sensor

Boiler options- Height adjustment frame for MCR 24 and MCR ..MI- Height adjustment frame for MCR 24/28 BIC- Connecting pipe kit Ø16/18 mm or Ø15/22 mm for height

adjustment frame- Pipe cover for MCR 24 and MCR..MI- Pipe cover for MCR 24/28 BIC- DHW expansion vessel for MCR 24/28 BIC- Flow collector- Mounting frame with disconnector for MCR 24- Mounting frame with disconnector for MCR.. MI- Condensates neutralisation calorifier- Wall bracket for neutralisation calorifier- Granule refill for neutralisation- BMR 80 domestic hot water calorifier- BMR 80 – MCR 24 connecting kit- SR 130 domestic hot water calorifier- SR 130 – MCR 24 connection kit- Propane conversion kit- Propane burner for MCR 34/39 MI