Deepwater Corrosion Services Inc. Specifications subject to change without notice Deepwater Corrosion Services Inc. USA: +1 (713) 983 7117 | UK: +44 (0) 1483 600482 | [email protected] FIELD CASE STUDY i-rod.com I-ROD ® 28 YEARS AFTER INSTALLATION The following images were captured in 2017 during a routine topside inspection of the first offshore structure where I-Rod pipe supports were specified (see the 13-year study for photos of the same support material in 2002). The system was installed in 1989 for less than $10,000 USD. These photos show the long-term success of the system at 13 and 28 years when Deepwter Corrosion Services, Inc. visited the structures for inspections in 2002 and 2017. 2002: 13 years after installation 2017: 28 years after installation WET CONDITIONS This fuel gas line is always wet (the green coloration is mold) and the beam paint system has failed, but no corrosion has occurred at the pipe support. FIFTEEN YEARS LATER... 28 years after installation, the fuel gas line shows some paint failure at the support but the I-Rod is still intact. LOW BEAM, HIGH-RISK Another pipe that stays wet, as evidenced by the mold and mildew on its surface. At 13 years after installation, the support was performing well. NO CREVICE CORROSION 28 years after installation, the coating is almost completely disintegrated and I-Rod still successfully prevented crevice corrosion. EXPOSED TO SPRAY AND SUN This support is remains well-preserved despite being exposed to harsh offshore conditions. NEW PAINT, SAME NU-BOLT The Nu-Bolt has received a few coats of paint over the decades but no new corrosion.

28-year inspection - Deepwater Corrosion Services Inc. · PDF fileThe following images were captured in 2017 during a routine topside inspection of the first offshore structure where

Embed Size (px)

Citation preview

Page 1: 28-year inspection - Deepwater Corrosion Services Inc. · PDF fileThe following images were captured in 2017 during a routine topside inspection of the first offshore structure where

Deepwater Corrosion Services Inc. Specifications subject to change without notice

Deepwater Corrosion Services Inc. USA: +1 (713) 983 7117 | UK: +44 (0) 1483 600482 | [email protected]

FIELD CASE STUDYi-rod.com

I-ROD® 28 YEARS AFTER INSTALLATION

The following images were captured in 2017 during a routine topside inspection of the first offshore structure where I-Rod pipe supports were specified (see the 13-year study for photos of the same support material in 2002). The system was installed in 1989 for less than $10,000 USD. These photos show the long-term success of the system at 13 and 28 years when Deepwter Corrosion Services, Inc. visited the structures for inspections in 2002 and 2017.

2002: 13 years after installation 2017: 28 years after installation

WET CONDITIONSThis fuel gas line is always wet (the green coloration is mold) and the beampaint system has failed, but no corrosion has occurred at the pipe support.

FIFTEEN YEARS LATER...28 years after installation, the fuel gas line shows some paint failure at the support but the I-Rod is still intact.

LOW BEAM, HIGH-RISKAnother pipe that stays wet, as evidenced by the mold and mildew on its surface. At 13 years after installation, the support was performing well.

NO CREVICE CORROSION28 years after installation, the coating is almost completely disintegrated and I-Rod still successfully prevented crevice corrosion.

EXPOSED TO SPRAY AND SUNThis support is remains well-preserved despite being exposed to harsh offshore conditions.

NEW PAINT, SAME NU-BOLTThe Nu-Bolt has received a few coats of paint over the decades but no new corrosion.

Page 2: 28-year inspection - Deepwater Corrosion Services Inc. · PDF fileThe following images were captured in 2017 during a routine topside inspection of the first offshore structure where

Deepwater Corrosion Services Inc. Specifications subject to change without notice

Deepwater Corrosion Services Inc. USA: +1 (713) 983 7117 | UK: +44 (0) 1483 600482 | [email protected]

FIELD CASE STUDYi-rod.com

VERTICAL APPLICATIONI-Rod is particularly effective on small-diameter screwed piping.

CLEAN CREVICEAfter 28 years the I-Rod shows no change long after the coating has failed.

RACKING UP THE YEARSI-Rod was used to dress beams beneath multiple pipes. No corrosion at 13 years.

A CLOSER LOOKThe same supports pictured above at 13 years. I-Rod is showing some signs of stress on the right pipe.

VERY LITTLE CHANGE15 years later, the crack has not compromised the support or intensified corrosion.

HOLDING UP WELLI-Rod supporting multiple pipes across a standard beam support.