2
FILENAME: DATE: SCALE: 2351 E 22ND ST 8/3/15 AS NOTED REV# REV.DATE: DGNR: SALES: RMF LANDLORD: CUSTOMER: DATE: DATE: Approval Signatures Required to insure that all spelling, colors, and specifications for sign(s) rendered meets customer & landlord approvals. This original design and all information herein are the property of Boyer Signs & Digital Graphics. Artwork is subject to return if not purchased. Any unauthorized use is forbidden. Copyright 2014 All rights reserved FACE TRIMS PROVIDED FASCIA COLOR REQUIRED RADIUS DIM. BUILDING DIM. FACADE ANGLE OTHER If required, customer to provide Boyer Signs & Digital Graphics with camera ready or appropriate digital file. Please contact your salesperson or Design Staff for appropriate file types. SIGN TYPE SPECIFICATIONS COLORS ARTWORK SIGN SURVEY - LETTERS SUPPORTED BY AND WIRES RUN THROUGH CHANNEL BOX (5” DEEP) - STRUCTURE FOR STAR TO BE FABRICATED ALUMINUM. - .040” BACKS AND RETURNS. - 5” RETURNS ON CHANNEL LETTERS AND LOGO. MATCH BRICK COLOR RETURNS / CHANNEL BOX WHITE PLEX BLACK TRIM CAP BLUE PLEX (COLOR TBD) & Digital Graphics, LLC 21611 Tungsten Rd. Cleveland ,OH 44117 PH:216-383-7242 FX:216-383-7271 CHANNEL LETTERS, LOGO WALL SINGLE FACE ILLUMINATED ST. VINCENT CHARITY MEDICAL CENTER 2351 EAST 22ND ST. CLEVELAND, OH 44114 INTERNALLY ILLUMINATED CHANNEL LETTERS AND LOGO SCALE 1/16”=1’-0” B:\_Customers\St.Vincent Charity Medical Center\2351 East 22nd\Preliminary Drawings THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. ALL WIRING MEETS NEC 2008 SPECIFICATIONS. SIGN TO BE WIRED TO A STANDARD 120 VOLT / 20 AMP CIRCUIT. 62'-0" 131'-0" 4'-4" 11'-9" 9'-8" APPROX. SIGN LOCATION---------> 5’-8” 13’-9” 34’-4” 34'-8"

2351 E 22ND ST (1)

Embed Size (px)

Citation preview

Page 1: 2351 E 22ND ST (1)

PROJECTING

EXTERNAL ILLUM.NON-ILLUM.

HANGING

GROUND

DOUBLE FACE

colorcolor

XX/XX/XXXFILENAME:

DATE: SCALE: 2351 E 22ND ST

8/3/15AS NOTEDREV#

REV.DATE: DGNR: SALES:RMFLANDLORD:CUSTOMER:DATE:DATE:

Approval Signatures Required to insure that all spelling, colors, and specifications for sign(s) renderedmeets customer & landlord approvals.

This original design and all information herein are the property of Boyer

Signs & Digital Graphics. Artwork is subject to return if not purchased.

Any unauthorized use is forbidden. Copyright 2014 All rights reserved

FACE TRIMS PROVIDEDFASCIA COLOR REQUIREDRADIUS DIM.BUILDING DIM.FACADE ANGLEOTHER

If required, customer to provide Boyer Signs & Digital Graphics with camera ready or appropriate digital file. Please contact your salesperson or Design Staff for appropriate file types.

SIGN TYPE SPECIFICATIONS COLORS ARTWORKSIGN SURVEY

- LETTERS SUPPORTED BY AND WIRES RUN THROUGH CHANNEL BOX (5” DEEP)- STRUCTURE FOR STAR TO BE FABRICATED ALUMINUM.- .040” BACKS AND RETURNS.- 5” RETURNS ON CHANNEL LETTERS AND LOGO.

MATCH BRICK COLORRETURNS / CHANNEL BOXWHITE PLEXBLACK TRIM CAPBLUE PLEX(COLOR TBD)

& Digital Graphics, LLC

21611 Tungsten Rd.Cleveland ,OH 44117

PH:216-383-7242FX:216-383-7271

CHANNEL LETTERS, LOGO

WALL

SINGLE FACE

ILLUMINATED

ST. VINCENT CHARITY MEDICAL CENTER2351 EAST 22ND ST.CLEVELAND, OH 44114

INTERNALLY ILLUMINATED CHANNEL LETTERS AND LOGO SCALE 1/16”=1’-0”

B:\_Customers\St.Vincent Charity Medical Center\2351 East 22nd\Preliminary Drawings

THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.

ALL WIRING MEETS NEC2008 SPECIFICATIONS.

SIGN TO BE WIRED TO A STANDARD 120 VOLT / 20 AMP CIRCUIT.

62'-0"

131'-0"

4'-4"

11

'-9"

9'-8"

APPROX. SIGN LOCATION--------->

5’-

8”

13

’-9

34’-4” 34'-8"

Page 2: 2351 E 22ND ST (1)

PROJECTING

EXTERNAL ILLUM.NON-ILLUM.

HANGING

GROUND

DOUBLE FACE

colorcolor

XX/XX/XXXFILENAME:

DATE: SCALE: 2351 E 22ND ST

8/3/15AS NOTEDREV#

REV.DATE: DGNR: SALES:RMFLANDLORD:CUSTOMER:DATE:DATE:

Approval Signatures Required to insure that all spelling, colors, and specifications for sign(s) renderedmeets customer & landlord approvals.

This original design and all information herein are the property of Boyer

Signs & Digital Graphics. Artwork is subject to return if not purchased.

Any unauthorized use is forbidden. Copyright 2014 All rights reserved

FACE TRIMS PROVIDEDFASCIA COLOR REQUIREDRADIUS DIM.BUILDING DIM.FACADE ANGLEOTHER

If required, customer to provide Boyer Signs & Digital Graphics with camera ready or appropriate digital file. Please contact your salesperson or Design Staff for appropriate file types.

SIGN TYPE SPECIFICATIONS COLORS ARTWORKSIGN SURVEYMATCH BRICK COLORRETURNS / CHANNEL BOXWHITE PLEXBLACK TRIM CAP

& Digital Graphics, LLC

21611 Tungsten Rd.Cleveland ,OH 44117

PH:216-383-7242FX:216-383-7271

CHANNEL LETTERS, LOGO

WALL

SINGLE FACE

ILLUMINATED

ST. VINCENT CHARITY MEDICAL CENTER

<--------EXISTING

BOTH NOT TO SCALE

PROPOSED

B:\_Customers\St.Vincent Charity Medical Center\2351 East 22nd\Preliminary Drawings

THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.

ALL WIRING MEETS NEC2008 SPECIFICATIONS.

SIGN TO BE WIRED TO A STANDARD 120 VOLT / 20 AMP CIRCUIT.

- LETTERS SUPPORTED BY AND WIRES RUN THROUGH CHANNEL BOX (5” DEEP)- STRUCTURE FOR STAR TO BE FABRICATED ALUMINUM.- .040” BACKS AND RETURNS.- 5” RETURNS ON CHANNEL LETTERS AND LOGO.

2351 EAST 22ND ST.CLEVELAND, OH 44114