Upload
dobao
View
270
Download
3
Embed Size (px)
Citation preview
EN 10305-5 (formerly DIN 2395)
EN 10219-2 EN 10210-2
Outside diameter (width B height H)
Tolerance acc. to EN 10305-5depending on the dimension:
from +/-0.2 mm up to +/-0.7 mm
for B, H < 100 mm: +/-1%, min. +/-0.5 mm, for 100 mm <= H,B <= 200 mm: +/-0.8%, for H,
B > 200 mm: 0.6%
+/-1% with an acceptable minimumvalue of +/-0.5 mm
Wall thickness T
for T <= 1.5 mm: +/-0.15 mm,for T > 1.5 mm: +/-10%
or +/-0.35 mm(lower value is valid)
for T <= 5 mm: +/-10%,for T > 5 mm: +/-0.5 mm
-10%/+6% for welded hollow sections,
-12.5%/+8% for seamless hollow sections
External corner radius R for T <= 2.5 mm: 1.5 T,for 2.5 mm < T <= 4 mm: 2.2 T
for T <= 6 mm: from 1.6 T up to 2.4 T,
for 6 mm < T <= 10 mm:from 2.0 T up to 3,0 T,
for T > 10 mm: from 2.4 T up to 3.6 T
maximum 3 T
Squareness 90° +/-1° 90° +/-1° 90° +/-1°
Convexity/concavity Included in external dimensiontolerances
maximum 0.8 %, minimum 0.5 mm
+/-1% of the side
Twist Vmax. 3 mm for B or H <= 30 mm,
max. B/10 or H/10 for Bor H > 30 mm
2 mm plus 0.5 mm/m of length 2 mm plus 0.5 mm/m of length
Straightness
for a (smaller) wall <= 30 mm:0,25% of total length,
for a wall (smaller) > 30 mm:0,15% of total length,no more than 3 mm
for the section of 1 m
0.15% for entire length, no more than3 mm for the section of 1 m
0.2% for entire length, no more than 3 mm for the section of 1 m
Mass M – On individual length: +/-6% On individual length: +/-6%
Standard length 6000 mm -0/+50 mm 6000 mm / 12000 mm, -0/+50 mm 12000 mm, -0/+500 mm
TOLERANCES