2014 Catalogue
Specialist Alarm Test Equipment
Alarm Troubleshooting Solutions
ACT Meters International LtdAbout
ContentsBattery Testing Equipment & Accessories ........................................................................................... 4 - 7
Test Equipment .................................................................................................................................... 8 - 13
Calibration Solutions .......................................................................................................................... 14 - 17
Alarm Troubleshooting Solutions .................................................................................................... 18 - 22
ACT Meters International Ltd is a British manufacturing supplier of specialist alarm test equipment
and false alarm troubleshooting solutions. We are responsible for all export sales from outside of
the UK. Our product range includes Battery Testers, InHouse Calibration Solutions, Electrical Test
Equipment and Alarm Protection Suppressors and Filters.
We supply to a global network of distributors from across North America, Europe and Australia. Our
equipment is ideally suited for alarm installers, electricians and electrical engineers.
ACT Meters International Ltd
Address: The Old Smithy, Church Road, Rainford, Merseyside, WA11 8HD, United Kingdom
Telephone: +44(0)1744 886660
Fax: +44(0)1744 886661
Website: www.actmeters.com
Email: [email protected]
Batt
ery
Test
ing
Equi
pmen
t
Intelligent Battery TesterACT GOLD PLUS
4Call: +44(0)1744 886660
Features
Take seconds to receive accurate Ah capacity
results of the most common lead acid battery
types using the GOLD PLUS Intelligent Battery
Tester. Standby SLA, cyclic GEL and car
FLOODED – the GOLD PLUS tests both 6V and
12V battery types quickly.
• Simulates a full 20 hour discharge test in seconds
• Designed for standby SLA, cyclic GEL and car FLOODED batteries
• Tests 6V batteries between 1.2Ah and 12Ah, and 12V batteries between 1.2Ah and 100Ah
• Displays DC Voltage and Ah capacity available
• Unique calibration control allows the battery tester to be calibrated to non standard battery
types
• Simple operation, without confusing conversion rates or user interpretation needed
• As recommended by battery manufacturers, recharge or replace a battery when its rated Ah
capacity falls below 65%
• Provides clear and accurate Ah readings enabling replacement batteries to be identified quickly
and easily
• Uses advanced pulse load technology to analyse Ah capacity, based on the battery’s temperature
and state of charge
• Advanced pulse load technology is significantly more accurate than measuring voltage and
internal resistance and does not deplete the battery unlike a conventional load tester
• Offers reliable, continuous testing
• Powered by the battery under test, with ultra low heat generation
• Perfectly suited as a bench tester or out on the job with the engineer
• Profitable; show the customer the result and increase your own battery sales by recommending
a new battery for their system
Batt
ery
Test
ing
Equi
pmen
t
Email: [email protected]
SpecificationsACT GOLD PLUS
5
Operating Voltage 6V and 12V DC
Reverse Polarity Protection Red LED Indication
Max Input Voltage 15VDC
Battery Types SLA, GEL and FLOODED
Battery Sizes 6V (1.2Ah - 12Ah) and 12V (1.2Ah - 100Ah)
Ah Capacity Test Simulated 20 hour (C20) load test to 10.50VDC
Ah Calibration Calibrated at 0 (zero) position to brand new fully charged premium brand SLA batteries
rated at C20hour at 20C (68˚F)
Ah Result Based on the battery under test temperature and state of charge
Ah Adjustment Provides ± Ah adjustment to brand new fully charged standby SLA, cyclic GEL and car
FLOODED lead acid batteries
Battery Table Recharge or replace battery when Ah capacity available falls below 65% of the battery’s
stated capacity
Display Backlit LCD
Flat Battery Warning 6V <5.30VDC, 12V <10.50VDC
Repeat Test Operation Can perform repeat tests continuously
DCV Accuracy ± 2% of displayed reading
Ah Accuracy ± 10% Fully charged premium brand C20 hour rated SLA batteries at 20 - 25˚C (68 - 77˚F)
Applied Pulse Load 6A 1.2Ah - 7Ah, 18A 8Ah - 100Ah
Ah Calibration Adjustment Approx ± 25 dgts
Case Construction High Impact ABS
Size 210(H) x 110(W) x 41(D)mm
Package ACT GOLD PLUS Intelligent Battery Tester, ACT GPTL Test Leads, ACT 430N Soft Carry Case,
ACT 3532 Terminal Connectors, Sample BTL Labels, Operating Instructions and Certificate
of Calibration
Additional Accessories
ACT BTL (250 labels)
Battery Tested Labels giving
insertions for Temperature,
Volts, Ah Readings, User
Initials & Date Tested
ACT 430N
Hard wearing carry case
with extra padding for
protecting the ACT GOLD
PLUS model
ACT 3532
Terminal Connectors used
with the GOLD PLUS model
for testing batteries with
recessed terminals
ACT GOLD PLUS CALKIT
InHouse kit for annual
calibration of the GOLD
PLUS model, more details
on page 17
Luminaire Battery Tester
Batt
ery
Test
ing
Equi
pmen
t
Call: +44(0)1744 886660
ACT CD4000
6
Take minutes not hours to test NICAD luminaire
batteries used in stand-alone emergency
lighting systems. The CD4000 performs 1 and
3 hour duration tests in minutes on 2.4V - 12V
rechargeable Nickel-cadmium batteries.
• Simulates a 1 hour duration test in under 6 minutes
• Identifies a low capacity or defective battery within 60 seconds
• Simulates a 3 hour duration test in under 12 minutes
• Testing the battery twice in succession will perform a 3 hour duration test on the battery
• Leaves a minimum 30% capacity available in the battery to operate the luminaire after testing
• Tests rechargeable Nickel-cadmium batteries from 2.4V – 12V above 1.5Ah
• All automatically with testing, pass and fail LED indicators
• Powered by the battery under test for all day reliability
• Robust and portable for out on the job site conditions
• Life time calibration
• Microprocessor controlled and contains no internal adjustments for recalibration
• Accuracy maintained by using the test leads supplied, if these become worn or damaged they
can be easily replaced
• Reverse polarity protection
• The 10Amp quick blow fuse is user replaceable and easily accessible on the top of the unit
Features
Batt
ery
Test
ing
Equi
pmen
t
Email: [email protected]
SpecificationsACT CD4000
Input Sockets RED+, BLACK- (4mm)
Test Leads 2m length, heavy duty with crock clips (ACT Part No: CD4000TL)
Power Supply Self powered by the battery under test (step-up inverter)
LED Indication RED/Fail, YELLOW/Testing and GREEN/Pass
Acceptable Batteries 2.4V to 12V NICAD
Minimum Battery Capacity Greater than 1.5Ah
Current Drawn During Test 0.5Amp
Test Times Normally under 6 minutes dependent on battery voltage
Heat Dissipation Between 23 to 115 Watts
Ambient Temperature -5 to 40C
Max. Heatsink Temp 100˚C
Input Protection Reverse Polarity and High Voltage Protection (18VDC max)
Input Fuse 10Amp Quick Blow Blade Type
Enclosure Flame Retardent Metal
Size 107(H) x 167(W) x 65(D)mm
Weight 1.5Kg
Package ACT CD4000, Spare Fuse, Test Leads and Operating Instructions
Call: +44(0)1744 8866608
Autoranging Multimeter CATIIIACT AVO300
Test
Equ
ipm
ent
Tough and compact, this digital multimeter
offers a range of measurement modes for AC
and DC applications, resistance and current
measurement.
• Fully autoranging
• Enables measurements on AC and DC voltage to 1000V, AC/DC current up to 10A and resistance
from 0.1Ω to 40MΩ
• Resistance, continuity and diode testing
• Resistance can be measured directly on the ohms range from 0Ω up to 1.999MΩ
• Continuity buzzer range checks low resistance between two points, sounding if the resistance is
less than 50Ω
• Diode range exists for testing forward and reverse bias operation of transistors and diodes
• Fused inputs protect both the user and the instrument in the case of excess current
• Data hold function allowing test data to be temporarily stored on screen for easy reference
• Mode function enables the selection of AC and DC measurement
• Separate bttery and fuse compartment
• Easy navigation with large buttons and central dial
• Large high contrast 3½ digit display
• Armoured casing
• Built-In rear stand
Features
Email: [email protected]
SpecificationsACT AVO300
Test
Equ
ipm
ent
Specifications Range Max Resolution Basic Accuracy
DC Voltage 400.0mV4.000V40.00V400.0V1000V
0.1mV1mV10mV100mV1V
+0.5% of rdg ±2 digits+0.8% of rdg ±2 digits
+1% of rdg ±2 digits
AC Voltage 4.000V40.00V400.0V1000V
1mV10mV100mV1V
+1% of rdg ±5 digits
+1.5% of rdg ±5 digits
DC Current 400.0μA4000μA40.00mA300.0mA10A
0.1μA1μA10μA100μA10mA
+1.0% of rdg ±3 digits
+2.5% of rdg ±3 digits
Resistance 400.0Ω4.000kΩ40.00kΩ400.0kΩ4.000MΩ40.00MΩ
0.1Ω1Ω10Ω100Ω1kΩ10kΩ
+0.8% of rdg ±5 digits+0.8% of rdg ±2 digits
+3% of rdg ±8 digits
Diode Test (Test Current) 0.3mA typical/Open <1.5V (Resolution> 1mV (Accuracy) +10% of rdg +5digits
Insulation Class2, Double insulation
Overvoltage Category CATIII 600V or 1000V CAT II
Display 4000 counts LCD display, 25.4mm high
Low Battery Indication A battery symbol is displayed when the battery voltage drops below the operating level
Over-range OL’ mark indication
Measurement Rate 2 times per second nominal
AutoPower Off Meter automatically shuts down after approx. 15 minutes of inactivity
Operating Environment 10˚C to 50˚C (14˚F to 122˚F) at < 70% relative humidity
Power One 9V Battery, NEDA 1604, IEC 6F22
Dimensions 182(H) x 82(W) x 55(D)mm
Weight 375g
Package AVO300 Autoranging Multimeter, Standard RED/BLACK Lead Set with Probes and
Operating Instructions
CALMASTER Calibration CheckBox for Multimeters
ACT CALMASTER
Ensure your multimeters are always deemed accurate with CALMASTER. This useful
bench tester checks that meter ranges are to calibration standard. It’s quick and easy
to use - and reduces the number of meters sent away unnecessarily for calibration. For
full product information turn to page 14.
Call: +44(0)1744 88666010Test
Equ
ipm
ent
mA Current ClampACT CA60
Essential for alarm installers, the ACT CA60 will
register low mA current readings without the
need for disconnecting circuit wires. Used with
your own multimeter it will measure milliamps
as well as amps.
Features
• Enables mA current readings to be taken without disconnecting the circuit wires
• Measures AC/DC current from 10mA to 60Amps
• Works with any multimeter with 200mV or/and 2V ranges for direct readout input impedance of
at least 1MΩ
• Fits into tight spaces within the circuit panel or a wire bundle to take readings
• LED indicator lights up when clamp meter power is low
• Recording such readings for future reference allows detector and cable faults caused by abnormal
currents to be identified easily
Output 1mV/10mA, 1mV/100mA
Input Resistance 10K
Jaw Opening 9mm
Power Requirement 9V Battery
Battery Life 100 hours typical with Alkaline
Low Battery Indicator RED LED
Size 195(H) x 70(W) x 33(D)mm
Output Coll cable with straight banana plug
Weight 250g
Package ACT CA60mA Current Clamp with test plugs and Operating Instructions
Email: [email protected] Te
st E
quip
men
t
Telephone Test SetACT 452
A trusted tool for telecom installations and
maintenance - checks for potential faults on a
telephone line where an alarm communicator
is fitted. Robust and simple to use.
Features
• Safe to use on analogue and digital lines
• Digital Service Protection (DSP) allows safe operation where telephone wiring may carry digital
signals, hazardous voltages or fault connections
• TALK and MONITOR modes enable lines to be tested without disrupting signals
• POL test button with GREEN/RED LEDs show correct or reverse A/B polarity connection
• Built-in over current protection against 230VAC and lightning surges
• Active polarity and fault LED indication
• Battery saving auto power on/off
• 3 Position Volume Boost Control with easy tone/pulse selection
• Finger tip microphone mute
• Rugged, drop proof design with belt hook
Long Line Operation With a 48V Feed > 5K Ω Loop, Minimum Current < 10Ma
DC Resistance Off-Hook Talk Mode: < 300 Ω, On-Hook Idle: > 5M Ω (10Ua @ 48VDC)
Monitor >5MΩ (20Ua @ 100VDC)
Monitor Impedance 100K Ω @ 1Khz
Dial Pulse 100Pps Break 60%
DTMF/Tone Dial Level -3Dm Typical
Flash/Timed Break Recall 100Ms (Switchable 600Ms, 300Ms)
Memory Dial 32 Digit Last Number Redial
PBX Pause 2 seconds
Low Battery Indication 2 Hours remaining continuous use
Automatic Power Shut Off Five minutes after disconnection
Package ACT 452 Telephone Test Set, crock-clip leads and Operating Instructions
Call: +44(0)1744 88666012Test
Equ
ipm
ent
Digital Sound Level MeterACT 1345
This Digital Sound Level Meter has a wide
dynamic range from 30 to 130dB, with
frequency weightings A and C for human sense
or machine monitoring purposes.
Features
• Meets IEC 651 Type 2 requirements
• Large, easy-to-read LCD display
• Dual range measurement (HI/LO)
• A & C frequency weighting
• Electret condenser microphone for high accuracy and long term stability
• Data Hold, Max Hold and low battery indication
Measuring Range LOW 35 to 100dB, HIGH 65 to 135dB (A & C)
Resolution 0.1dB
Accuracy ±1.5dB
Frequency 31.5Hz to 8kHz
Time Weighting Fast/Slow (A & C)
Microphone ½” Electret Condenser
Power Supply 1 x 9V Battery
Dimensions 210(H) x 55(W) x 32(D)mm
Weight 230g
Package ACT 1345 Digital Sound Level Meter, Case and Operating Instructions
Email: [email protected] Te
st E
quip
men
t
Audible Circuit TesterACT Verifier
Verifier enables an alarm installer to quickly
walk-test a circuit installation and audibly
trace hidden cables, test resistance and locate
intermittant faults in a fraction of the normal
time. An ideal tool to use during commissioning,
maintenance and take-over inspections and
troubleshooting first fix installations.
Features
• Uses sound to detect
• Connects to the circuit and passes an audible tone throughout cables and circuit devices
• Audible tone is heard through the supplied inductive amplifier probe when passed near the
cable or individual device
• Healthy devices will produce a clear, constant tone
• Troublesome devices will produce a distorted, varying tone
• Traces hidden cables and pinpoints cable faults
• Identifies devices connected to unmarked cables
• Identifies good and faulty magnetic contacts
• Tests operation and sensitivity of PIR motion detectors
• Verifies sensitivity adjustment of shock sensors
• Audibly Test Normally Closed and End of Line Resistance Circuits
Variable Resistance Tones Low 0Ω to high 250Ω
Low <250Ω to high 25KΩ
Low <25KΩ to high 250KΩ
Battery Type 9V (PP3) Alkaline
Enclosure Flame retardant ABS
Size 110(H) x 63(W) x 20(D)mm
Weight 150g
Package ACT VERIFIER, Inductive Amplifier Probe with adjustable volume control, Magnetic Test
Screwdriver, Carry Case and Operating Instructions
Call: +44(0)1744 88666014Calib
rati
on S
olut
ions
ACT CALMASTERCalibration CheckBox for MultimetersIdeal for companies that have many
multimeters in service that need calibrating
regularly. CALMASTER is a useful bench
tester for checking that meter ranges are to
calibration standard. It’s quick and easy to
use - and reduces the number of meters sent
away unnecessarily for calibration.
Features
Resistance 00.0Ω up to 100K
AC Volts 0.0 - 230VAC
DC Volts 0.0 - 36VDC
DC Current 1mA, 10mA, 100mA and 1 Amp
Fuse Protection 250VAC 1.6 Amp Max
Dimensions 132(H) x 216(W) x 102(D)mm
Weight 2.2kg
Package ACT CALMASTER, Test Leads, Test Labels and Operating Instructions
• Performs InHouse testing and verification of multimeter ranges
• Check accuracy at any time to ensure meter ranges meet BS ISO9001:2008 requirements
• Works in conjunction with one single calibrated multimeter - the only meter that should ever be
sent away to be calibrated
• Compares the accuracy between the meter under test and calibrated meter
• Allows the engineer to test the various ranges for AC/DC Voltage, Resistance and DC Current.
• Each range reading can be compared against the calibrated meter and logged onto the Calibration
Test Result Sheet provided
• If readings from the meter under test are within ±5% of the calibrated meter, it is deemed
accurate and can be passed
• Simple in operation
• Ideal for companies that have many multimeters in service
Email: [email protected] Ca
libra
tion
Sol
utio
ns
Calibration CheckBox for ACT IBTsACT BATMASTER
Verify accuracy of all ACT Intelligent Battery
Testers with BATMASTER. This InHouse bench
tester allows the engineer to check accuracy
at any time and carry out recalibrations when
necessary, using an ACT CALKIT. A cost effective
solution for those who have many ACT battery
testers in service.
Features
Pass Rate Voltage Equals ±5% and Ampere Hour: 7Ah - 9Ah
Operating Temperature 20 - 30ºC (68 - 86ºF)
RED LED Indicates to replace BATMASTER battery (Yuasa NP7Ah-12V)
Dimensions 164(H) x 120(W) x 145(D)mm
Weight 3kg
Package ACT BATMASTER, Test Leads and Operating Instructions
• Designed for ACT RED, GOLD and GOLD PLUS Intelligent Battery Testers made by ACT Meters Ltd
• Allows an engineer to verify the accuracy of each battery tester at anytime, quickly and easily
• Works in conjunction with your own calibrated multimeter - this is the only meter that you must
ensure is calibrated to standard
• Compares the DCV accuracy between the battery tester under test and calibrated meter
• Test and verify the accuracy of the battery tester under test against the rated Ah capacity of the
BATMASTER unit
• If readings from the battery tester under test are within ±5% of the calibrated meter, it is deemed
accurate and can be passed. If however, the Ah readings are low or erratic, the engineer can
recalibrate using the recommended ACT CALKIT
• BATMASTER has connection posts for the battery tester under test and calibrated meter
• Simple LEDs give unit status indication
Call: +44(0)1744 88666016Calib
rati
on S
olut
ions
For ACT Intelligent Battery TestersACT CALKITS
RED IBT CALKIT
Enables InHouse Calibration of your ACT
RED Intelligent Battery Tester. Each CALKIT
consists of new calibrated test leads, clips,
diode, replacement labels, sample BTL labels
and instructions. Please note, soldering is
required.
GOLD IBT CALKIT
Enables InHouse Calibration of your ACT
GOLD Intelligent Battery Tester. Each CALKIT
consists of new calibrated test leads, clips,
diode, replacement labels, sample BTL labels
and instructions. Please note, soldering is
required.
Email: [email protected]
For ACT Intelligent Battery Testers
17
ACT CALKITS
Calib
rati
on S
olut
ions
GOLD PLUS IBT CALKIT
Enables InHouse Calibration of your ACT
GOLD PLUS Intelligent Battery Tester. Each
CALKIT consists of replacement calibrated
plug-in test leads, new front labels and
instructions.
ACT LB1
Used for recording calibration data. Each roll
contains 250 labels with insertions for Serial
Number, User Initial, Calibration Date and
Recalibration Due Date.
Call: +44(0)1744 88666018Alar
m T
roub
lesh
ooti
ng S
olut
ions
Alarm Troubleshooting
Stop induced AC and nearby lightning from
causing false alarms and system malfunctions
with the ACT 1313. This 12V spike suppressor
decouples AC from cables and clamps the supply
against spikes.
ACT 1313
• Protects alarm control equipment and
detectors from induced AC and nearby lightning
• Decouples induced AC from every alarm cable connected to the control panel
• Clamps the 12VDC supply against spikes to the control panel, alarm detectors and plug-on
communicators
• Fit as standard - just one to the control panel and each PSU
• Connect RED+ and BLACK- across the 12VDC auxiliary supply and GREEN to mains Earth
12V Spike Suppressor
Stop induced AC and nearby lightning from
causing system malfunctions on the fire
alarm panel with the ACT 1414. This 24V spike
suppressor decouples AC from cables and
clamps the supply against spikes.
ACT 1414
• Protects fire alarm system from induced AC
and nearby lightning
• Decouples induced AC from every alarm cable connected to the control panel
• Clamps the 24VDC supply against spikes
• Connect RED+ and BLACK- wires across any 24V fire alarm zone, connect GREEN to mains Earth
• NOTE: Only one 24V spike suppressor is required for the control panel
24V Spike Suppressor
Email: [email protected] Al
arm
Tro
uble
shoo
ting
Sol
utio
ns
Alarm Troubleshooting
This advanced 12V spike suppressor has two
functions. Firstly it will eliminate false alarms
caused by induced AC and RFI interference.
Secondly, it features a bi-coloured LED allowing
cable faults supplying DC power to motion
detectors or any 12V detection device to be
identified easily.
NEW ACT 1313 PLUS
• Eliminates false alarms caused by induced AC and RFI interference
• Identifies cable faults supplying DC power to motion detectors or any 12V detection device
• Eliminates induced AC and RFI
• Attenuated by up to 60dB on all DC power cables
• Bi-coloured LED identifies any potential DC power overload or low resistance fault on any cable
connected
• Connect directly between the control panel or PSUs auxiliary 12VDC supply to motion detectors
or other powered detection device
• Twin terminal blocks, 2X RED+ and 2X BLACK-, enable power cables to be grouped and connected
easily
Bi-coloured LED
• GREEN shows ‘no fault’ whereas RED indicates ‘fault exists’
• If the RED LED is lit, simply disconnect DC power cables one at a time to identify the troublesome
circuit
• If the RED LED is lit with all power cables removed, this indicates that the panel or PSU DC voltage
is insufficient to power motion sensors and other detection devices effectively against false
alarms
Advanced 12V Spike Suppressor
Call: +44(0)1744 88666020Alar
m T
roub
lesh
ooti
ng S
olut
ions
Alarm Troubleshooting
Providing up to 4,500 Amp spike suppression,
the ACT 2323 protects all security and fire
alarm panels, CCTV cameras and access control
equipment against nearby lightning.
ACT 2323
• Provides up to 4,500 Amp continuous spike
protection across live, neutral and Earth
• Prevents false alarms and system malfunctions caused by nearby lightning
• Protects all security and fire alarm panels, CCTV cameras, access control equipment and
security lighting
• Neat modular shape, fits easily with simple parallel connections to LNE
230V Mainspike Suppressor
Prevents electrical RFI from affecting the 12VDC
supply on metal control panels. An essential
alarm troubleshooting solution.
ACT 1166
• Protects steel boxed control panels against
RFI signals
• Prevents RFI signals from feeding back
from mains Earth and onto the 0V - this can affect the 12VDC supply to the control panel,
communicator and alarm detectors
• Connects in line with mains Earth inside the control panel
Earth Line Choke
Email: [email protected] Al
arm
Tro
uble
shoo
ting
Sol
utio
ns
Alarm Troubleshooting
Protects PIRs and dual detectors against RFI
signals and stabilises the DC supply in the event
of a DC spike.
ACT 1376
• Stops RFI from affecting PIRs and dual
detectors
• Stabilises and powers PIRs and dual detectors
for up to 250ms in the event of a DC spike
• Eliminates replacing non-defective motion sensors
• Fits either inside or behind the detector with the 12VDC supply connected through
PIR Stabiliser
A powerful 1Amp rated RFI filter used to reduce
RFI from affecting alarm detectors, sounders and
DC access control circuits. They are particularly
beneficial where data corruption occurs on
keypads and LIMs.
ACT 2468
• Powerful 1Amp rated RFI filter
• Reduces RFI to alarm detectors, sounders
and DC access control circuits
• Works on 12V and 24VDC normally closed, end-of-line and fire alarm circuits
• Offers virtually no resistance to DC circuits but will reduce RFI signals between 2.5Hz and
800MHz, allowing them to work quicker and become more cost effective than re-wriring in
screened cables
• Connects between alarm circuit wiring and control equipment
• Supplied as a 1 x 8 block which can be snapped apart to make 2 x 4 way or 4 x 2 way
8 Way RFI Filter
Call: +44(0)1744 88666022Alar
m T
roub
lesh
ooti
ng S
olut
ions
Alarm Troubleshooting
Enables analogue alarm systems to operate
securely on broadband and ADSL lines. The
ACT 4343, housed within a surface mountable
box, provides the correct filtering of signals to
allow simultaneous use of both the auto dialler
and broadband services. Suitable for REDCARE,
digital communicators and speech dialers.
ACT 4343
• Allows analogue alarm signals to operate securely on broadband and ADSL lines
• Meets SIN 346 requirements
• Provides the correct filtering of signals to allow simultaneous use of both the auto dialler and
broadband services
• Surface mountable box with screw terminals for quick and easy connection
• Fits adjacent to the panel or centre plastic section containing the PCB
• Terminal connections can be wired directly from the BT line and alarm autodial equipment
• Suitable for REDCARE, digital communicators and speech dialers
• ABS Box Size: 85(H) x 85(W) x 35(D)mm
ADSL Broadband Filter
Email: [email protected]
ACT Meters International Ltd
Address: The Old Smithy, Church Road, Rainford, Merseyside, WA11 8HD, United Kingdom
Telephone: +44(0)1744 886660
Fax: +44(0)1744 886661
Website: www.actmeters.com