    HVAC ZONE

    DAMPERS&CONTROLS

  • 8/12/2019 2011FOSTER Understanding Zoning

    2/99

    Who is ?New trade name ofPreviously marketed zoning under the trade name of 1964-

    99:

    First company to market and sell HVAC Zoning.Sold more zoning system than the others.

    Always Leading Edge ProductsMaking Zoning AffordableSimplest to Install and Wire

    Corporation.

    Trol-A-Temp is a registered trademark of Honeywell International. There is no affiliation between Honeywell and Trolex Corporation and Honeywell.

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    3/99

    Has completed the required training to sell, install, checkout, and troubleshoot Zone Damper Control Systems. And areherby awarded this certificate with a honorary degree in

    ZONEOLOGYA concentrated program of study on the operation of zone dampers and control systems of forced air heating andcooling systems.This training program is recognized by NATE and is eligible for Re-Certification CEU credits. Please sign your name onthe attendance sheet with your NATE Number and we will forward this to NATE.

    Be it known to all the world that

  • 8/12/2019 2011FOSTER Understanding Zoning

    4/99

    Zoning is Not New

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    5/99

    OEMs Have Zoning

    Promotional Literature from the 1980s

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    6/99

    Man

    ualD

    ResidentialAirDistribu

    tionSystems

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    7/99

    Manual JLoad Calculations

    Manual DDuct Design

    Manual ZrZone ControlComing Late 2011?

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    8/99

    One ThermostatControls Central

    HVAC System

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    9/99

    Downstairs

    UpstairsTwo Ton

    Two Ton

    Some state building codes require zoning on two level homes. North Carolina is on

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    10/99

    Downstairs

    UpstairsMaster BR

    UpstairsKids/Guest

    ZoneDampers

    A 3 Zone System

    will still cost less

    than two separate

    units!

    3.5 Ton

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    11/99

    Two ZonesFirst Floor and Second Floor

    Zone One Zone Two

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    12/99

    Three Zones

    Zone One

    Zone Two

    Zone Three

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    13/99

    Four Zones

    Zone One

    Zone Two

    Zone Three

    Zone Four

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    14/99

    Zoning Products

    ZoneDampers

    Zone

    ControlPanels

    Parallel Blade DampersSpring Return Retro-Round andIn-Line Round Dampers

    Single Stage2 and 3 Zone

    Multi-Function4 Zone Expandable

    2 Zone AdderSingle Stage and Heat Pump2 and 3 Zone

    By-Pass Dampers

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    15/99

    Obstacles?Zone Thermostats

    Control Panel

    Whats

    Preventing

    Installers fromputting Zoning

    on Every HVACSystem?

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    16/99

  • 8/12/2019 2011FOSTER Understanding Zoning

    17/99

    Why Not Zoning?Consumers Want It!

    Surveys have shown over 60% of Homeownerswould pay $1,200 for zoning when offered.

    According to an NAHB survey, when askedwhat they would be willing to pay if their energycosts could be reduced roughly $1,000 a year, 51percent checked $5,000 to $10,999 and another16 percent said $11,000 or more. Thirty-two

    percent said they were willing to pay less than$5,000.

    Contractors Do Not Offer It.

    Hydronic Heating Systems

    Practically every boiler is zone withvalves or circulators.

    Commercial Offices are Zoned

    In Commercial its called Variable AirVolume (VAV).

    Zone Thermostats

    Control Panel

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    18/99

    Why Not Zon ing?

    All Hydronic andHot WaterSystems

    are Zoned

    Circulating Pump

    Zone Valve

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

    http://www.bellgossett.com/homeowners/ProductPages/Parts-Comfort-Trol-Zone-Control-Valve.asphttp://www.bellgossett.com/homeowners/ProductPages/Parts-Comfort-Trol-Zone-Control-Valve.asp
  • 8/12/2019 2011FOSTER Understanding Zoning

    19/99

    Why Not Zon ing?

    Its even in many New CarsIndividual Driver and Passenger Temperature Control

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    20/99

    If you have one of these for each room?Why not one of these?

    Why Not Zon ing?

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    21/99

    Zoning $aves Energy

    Utilities and others promote this!

    Public Service Electric and Gas, a New Jersey Utility

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    22/99

    Zoning $aves Energy

    11% Electric Input Savings

    33% Fewer Air Conditioner Cycles

    1990 Energy Study done on actual home in Minneapolis, MN

    NO ComfortNO Savings

    SavingsNO Comfort

    ComfortNO Savings

    ComfortAND Savings

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    23/99

    25% Energy Savingswith

    PROPER

    Zone Controlusing setback

    or

    20% Extra Cost ofComfortAll stats at same temperature

    Zoning $aves Energy

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

    More Information www.zonefirst.com/energysavings

  • 8/12/2019 2011FOSTER Understanding Zoning

    24/99

    Opportunities?

    Residential New Construction100%Can be designed from the start.

    Residential Retrofit50%

    Access to ductwork. May need modifications.

    Hydronic w/Air Conditioning Add-onCreate an equal number of zones for bothheating and cooling.

    Same Thermostat for Heat and Cool (RH/RC)

    Commercial90%Overhead ducts in False Ceilings.

    Retrofit for change from Single Tenant to Multi-Tenant

    Zone Thermostats

    Control Panel

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    25/99

    Zoning System Design

    Every forced airsystem can be zoned!

    Zoning can make a good systemgreat!

    It can also make a poor systemworse!

    Zoning is Not a cure all for a poorlyMarch 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    26/99

    Zoning System Design

    Every good forced air system can be zoned!

    ITS JUST A MATTER OF COST.

    HOW MUCH WILL IT COST = HOW MUCH DO YOU WANT TO SPEND!

    Is it practical? Retrofit?Yes! Overhead A/c systems.

    New constructionYES!

    It comes down to imagination and creativity.

    You can for different reason

    OccupancyLiving, sleeping, recreation

    ExposuresNorth, south, east, westLevelseach floor be a zone

    Loadskitchen, solar, fireplaces

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    27/99

  • 8/12/2019 2011FOSTER Understanding Zoning

    28/99

  • 8/12/2019 2011FOSTER Understanding Zoning

    29/99

    Airflow characteristics

    Garden Hose

    As the water flows out of the hose there is:

    A certain volume of water, Gallons Per Minute (GPM) = Air CFM

    Water flows out at a certain velocity = Feet Per Minute FPM = Same as air.

    Water has a pressure behind it in the system to make it come out = Static Pressure, usually measured

    in Pounds per Square Inch = PSI = Air S.P.

    A ir is a fluid just l ike water

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    30/99

    Airflow characteristics

    Garden Hose

    Cover opening with thumb

    As your thumb begins to close up the hose opening the following occurs:

    Thumb feels increased pressure = increased static pressure

    Water from hose shoots farther = increased velocity

    Same volume of water flows.up until the point where your thumb can

    apply more pressure that that of the water coming from the hose. Then

    youre reducing the volume of water.

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    31/99

    Duct Design for Zoning

    The main principle of duct design forforced air zone control is to maintain a

    constant volume of air (CFM) through

    the HVAC unit, when only one zone is

    open and maintain adequate airflow

    when all zones are open.Be carefu l no t to oversize the duct sys tem.

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    32/99

    Duct Design for Zoning

    Over-blow/SizingSystem that are 2 or 3 Zones and similar in size

    Using Single Speed Blowers

    By-PassUse a separate controlled duct to relieve excess air

    Distributed Relief

    Using Minimum Position or other method toreleive air into satisfied zones.

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Three Methods Stated in NEW ACCA Manual Zr

  • 8/12/2019 2011FOSTER Understanding Zoning

    33/99

    Duct DesignNew Installations

    Example

    2-1/2 Ton

    (1000 CFM)

    Blower

    600 - 700 CFM (60-70%)

    600 - 700 CFM (60-70%)

    600 - 700 CFM(60-70%)

    Over Size Each Trunk

    Duct To Handle 2/3 of

    Total System CFM

    Remember this is a Rule of Thumb.

    Should be used as a minimum.

    Two Zones would be more like 700 CFM/zone.

    Three Zones would be more like 600 CFM/zone.

    Have an adequate numbers of take-offs for each zone.

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    34/99

    Duct Design

    2-1/2 Ton(1000 CFM)

    Blower

    600 - 700 cfm (60-70%)

    600 - 700 cfm (60-70%)

    600 - 700 cfm(60-70%)

    Five 6 Round Branch Ducts on Each Trunk

    Duct

    By-Pass is typically not

    required.

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

    Air moves into the zone duct at a higher velocity and pressure,but not enough to over come the static rating of the blower.

  • 8/12/2019 2011FOSTER Understanding Zoning

    35/99

    Duct DesignFor Rectangular

    System CFM Zone Duct Outlets

    800 CFM 12 x 8 5-6 Rounds

    1,000 CFM 14 x 8 5-6 Rounds1,200 CFM 16 x 8 6-6 Rounds

    1,400 CFM 18 x 8 5-7 Rounds

    1,600 CFM 20 x 8 5-7 Rounds2,000 CFM 22 x 8 5-8 Rounds

    *Learn this chart youll know whether or not a by-pass is needed or not.

    Minimum Zone Duct Sizes

    and Outlets Where By-Pass

    is NOT REQUIRED

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    36/99

    Duct DesignFor Round Ducts

    System CFM Zone Duct Outlets

    800 CFM 12 Round 5-6 Rounds

    1,000 CFM 12 Round 5-6 Rounds1,200 CFM 12 Round 6-6 Rounds

    1,400 CFM 14 Round 5-7 Rounds

    1,600 CFM 14 Round 5-7 Rounds2,000 CFM 16 Round 5-8 Rounds

    Minimum Zone Duct Sizes

    and Outlets Where By-Pass

    is NOT REQUIRED

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    37/99

    B P L ti

  • 8/12/2019 2011FOSTER Understanding Zoning

    38/99

    By-Pass Location

    2-1/2 Ton

    (1000 CFM)

    Blower

    600 CFM

    300 CFM180 CFM

    120

    CFM

    Return Air Duct

    By-PassDuct

    Static Pressure

    Regulating Damper

    Typical By-Pass Application

    Lessens the need for Capacity Controls.

    Always try to run by-pass into return asfar away from blower as possible.

    Air By-Passedfurther away fromblower has moretime to mix with RAand be temperedby RA from otherareas.

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

    Typical Duct Layouts

  • 8/12/2019 2011FOSTER Understanding Zoning

    39/99

    Typical Duct Layouts

    HVAC

    Unit

    Parallel Supply & Return Trunks

    Supply

    Return

    Zone Each Branch Duct

    SPRD

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    40/99

    Dump Zone

    2-1/2 Ton

    (1000 CFM)

    BlowerReturn Air Duct

    HallwayEntrance Foyer

    Common Area with suppliesfrom Dump duct on one end,

    return on other end of area.

    March 23-25, 2011Landsdowne, VA

    -

    z ng e y

  • 8/12/2019 2011FOSTER Understanding Zoning

    41/99

    z ng e y-Pass

    Total CFMSmallest Zone CFM= By-PassCFM1,200 CFM (3Tons) - 300 CFM = 900 CFM for By-Pass

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

    B i B P D

  • 8/12/2019 2011FOSTER Understanding Zoning

    42/99

    Barometric By-Pass Damper

    CFM Capacity SPRD Size

    1,000 CFM 12 x 81,200 CFM 12 x 10

    1,400 CFM 12 x 12

    1,600 CFM 20 x 8

    1,800 CFM 20 X 10

    2,000 CFM 20 X 12

    CFM Capacity SPRD Size

    300 CFM 7

    400 CFM 8

    600 CFM 9

    750 CFM 10

    1,200 CFM 121,800 CFM 14

    2,400 CFM 16

    3,000 CFM 18

    4,000 CFM 20

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    The counter balance weight moves up and

    down the arm.The arm can also be offset to the blade to

    add more or less weight.

    All Zones Open the By-Pass should be

    closed. As the larger zones Close, the by-

    pass opens to relieve the excess air.

    To adjust, close all zone dampers, except

    for the smallest zone. Check the static and

    noise level and adjust by-pass damper

    open to maintain that level,

    M d l ti B P

  • 8/12/2019 2011FOSTER Understanding Zoning

    43/99

    Modulating By-Pass

    Operates Independently of the Zone Dampers

    Modulates based on static pressure in ductsystem.

    Opens as duct pressure increases above 0.3

    W.C.

    Closes as duct pressure drops below 0.2 W.C.

    Stops between 0.2 and 0.3 W.C.

    By-Pass Control needs a dead band.

    Do Not want by-pass to HUNT seeking balance.

    Insure a by-pass sensor matches the systemstatic Higher for Commercial Applications thenResidential

    Static Pressure Switch

    Modulating

    ZD Damper

    ModulatingRD Damper

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

    i d i bl d

  • 8/12/2019 2011FOSTER Understanding Zoning

    44/99

    Zoning and Variable Speed

    Number of Zone Dampers Closed

    StaticPressureandFanSpeed

    0 1 2 3

    0.4

    0.3

    0.2

    0.1

    All Dampers

    OPEN

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    i d i bl S d

  • 8/12/2019 2011FOSTER Understanding Zoning

    45/99

    Zoning and Variable Speed

    Number of Zone Dampers Closed

    StaticPressureandFanSpeed

    0 1 2 3

    0.4

    0.3

    0.2

    0.1

    Static Pressure Control Range

    As By-Pass Damper Opens Static Drops, Blower Slows

    By-Pass Damper Closes

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    O h F f B P

  • 8/12/2019 2011FOSTER Understanding Zoning

    46/99

    Other Forms of By-Pass Distributed Relief

    2-1/2 Ton

    (1000 CFM)

    Blower

    600 CFM

    300 CFM180 CFM

    120 CFM

    Return Air Duct

    CAUTION:

    If smaller zone faces north and largerzone is south with a lot of solar gain,could cause overheating on coolersunny days.

    Set larger Zone Dampers to a minimum

    position or undersize damper to duct.

    This allows continuous air circulation to

    all zones.

    May be enough not to require a separate

    by-pass.

    Keeps main zones from calling as often.

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    47/99

    HVACUnit

    Upstairs ZoneDownstairs Zone

    Damper Cells on Plenum

    Top

    View

    Plenum Split can go inalmost any direction.

    Dampers install side by

    side in top or plenum.

    GREEN SAVINGSSUSTAINABLE COMFORT

  • 8/12/2019 2011FOSTER Understanding Zoning

    48/99

    Multi-Zone Damper Cells Top View

    3 Zones4 Zones

    2

    12x10

    1 20x84 10x10

    Based on typical 20x20 plenum. Sizes can be whatever fits. Use your ductulator.

    GREEN SAVINGSSUSTAINABLE COMFORT

    A 3 Z Pl S t

  • 8/12/2019 2011FOSTER Understanding Zoning

    49/99

    A 3 Zone Plenum System

    2 12x10

    1 20x8

    Based on typical 20x20 plenum. Sizes can be whatever fits. Use your ductulator.

    Living Room Dining Room

    ndFloorBedroomsKitchenFamily Room

    GREEN SAVINGSSUSTAINABLE COMFORT

    A 4 l S

  • 8/12/2019 2011FOSTER Understanding Zoning

    50/99

    A 4 Zone Plenum System

    4 10x10

    Based on typical 20x20 plenum. Sizes can be whatever fits. Use your ductulator.

    Living RoomDining Room

    ndFloorBedrooms

    KitchenFamily Room

    MasterBedrooms

    GREEN SAVINGSSUSTAINABLE COMFORT

  • 8/12/2019 2011FOSTER Understanding Zoning

    51/99

    14

    10

    10

    10

    10

    12

    12

    7

    7

    7

    7

    7

    7

    7

    7

    Round Duct Layout using Flex Duct

    Outlets to

    individual

    rooms.

    RD Zone Damper

    Ductboard triangles splitduct and provide good

    diffusion

    GREEN SAVINGSSUSTAINABLE COMFORT

  • 8/12/2019 2011FOSTER Understanding Zoning

    52/99

    Typical Duct Layouts

    HVACUnit

    Return

    Supply

    Up Down

    Up DownUp DownUp Down

    Up Down

    Up Down

    Up DownUp Down

    PROBLEM?

    GREEN SAVINGSSUSTAINABLE COMFORT

    Zone Economics

  • 8/12/2019 2011FOSTER Understanding Zoning

    53/99

    Zone Economics

    HVACUnit

    Return

    Supply

    Up Down

    Up DownUp DownUp Down

    Up Down

    Up Down

    Up DownUp Down

    SOLUTION!

    Run a second trunk parallel to main.

    Move one zones outlets to new trunk.

    Add dampers to main and new trunk.

    NOTE: Ductwork is

    CHEAPER than

    dampers!

    GREEN SAVINGSSUSTAINABLE COMFORT

    Zoning Plan

  • 8/12/2019 2011FOSTER Understanding Zoning

    54/99

    Zoning PlanDetermine the number of Zones

    Review the Duct LayoutPerform Takeoff to get the size and number ofdampers

    for each zone

    Zoning List

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    55/99

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Existing Systems

  • 8/12/2019 2011FOSTER Understanding Zoning

    56/99

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Existing Systems

    Zoning Retrofit Systems

  • 8/12/2019 2011FOSTER Understanding Zoning

    57/99

    g y

    Overhead Attic Systems

    Ducts easily accessible

    Simply cut-in dampers

    Easy to run wires

    Mount Panel near unit

    Use Wireless Thermostats

    Shut off unused roomsBalance Temperature between rooms

    The larger the house the greater the need.

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Retrofit Zoning Dampers Insertable

  • 8/12/2019 2011FOSTER Understanding Zoning

    58/99

    g pRound Dampers

    Cut a 3/4 slot in the duct

    Insert and secure with screws, provided

    Model RRP with Plug-In Motor

    Model RRM with 24VAC Three Wire Motor

    Outlet Zone Damper

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    59/99

    Retrofit Zoning Zone Each Branch Duct

  • 8/12/2019 2011FOSTER Understanding Zoning

    60/99

    Retrofit Zoning

    HVAC

    UnitSupply

    Return

    Zone Each Branch Duct

    By-Pass

    Outlet Zone

    Damper

    Retro-Round

    DamperMain

    Thermostat

    Wirelresss

    Thermostat

    Wirelresss

    Receiver

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Zoning Commercial

  • 8/12/2019 2011FOSTER Understanding Zoning

    61/99

    g

    Is this your idea of Zoning?

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    62/99

    Zoning Commercial

  • 8/12/2019 2011FOSTER Understanding Zoning

    63/99

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    g

    Spring Return Zone Dampers

  • 8/12/2019 2011FOSTER Understanding Zoning

    64/99

    p g p

    Rectangular/Square Side Mount

    Round Single Blade

    All Dampers are 24 VAC, 7 Watts.

    Power Closed, Spring Open (Fail-Safe Operation).

    All Dampers Reversible to Power Open

    Adjustable Minimum Position Close.

    NEW Silent Spring Return MotorRectangular-Square

    Bottom Mount

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Adjustable Minimum Position

  • 8/12/2019 2011FOSTER Understanding Zoning

    65/99

    Adjustable Minimum Position

    All Spring Return Dampers can be

    easily adjusted for a Minimum Positionwhen closing to allow a minimumamount of air for by-pass and aircirculation.

    With the damper Normally Open

    Loosen the Set Screw

    Move set screw and align with desiredminimum position and tighten.

    Power damper closed and damper willstop at minimum position.

    NOTE: This set screw and label does not

    indicate the damper position and is used only to

    set the minimum position.

    March 23-25, 2011Landsdowne, VA2004-11 ZONEFIRST

    Other Damper Applications

  • 8/12/2019 2011FOSTER Understanding Zoning

    66/99

    Other Damper Applications

    Rectangular/Square Side Mount

    Round Single Blade

    Fresh Air Intake/Make-Up Air

    Return Air Control between high and low

    returnsAutomatic Humidifier Damper

    Wherever theres a Duct, Theres a need for

    a need for an automatic damper.

    Rectangular-Square

    Bottom Mount

    March 23-25, 2011Landsdowne, VA2004-11 ZONEFIRST

    Independent Zone

  • 8/12/2019 2011FOSTER Understanding Zoning

    67/99

    p

    Use a thermostat to

    operate a single or

    multiple dampers.

    NO Control of the

    HVAC.

    Used for over conditioned

    rooms or zones.

    RY W G C

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    68/99

    TWO and THREE ZONE

    Non-Expandable

    Single Stage

    Gas-Oil-Electric Heating and Cooling

    Two Stage and Heat Pump

    Two Stage Heat/CoolElectric HP & Dual Fuel

    FOUR ZONE

    Expandable to 10 Zones

    All-In-One

    Up to 3H/2C and Heat Pump (No Dual Fuel)

    All Panels operate the same.

    All Zones Satisfied All Zone Dampers Open

    Any Zone Calls Calling Zone Remains Open

    Closes Dampers to Satisfied Zones

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Single Stage Heat/Cool

  • 8/12/2019 2011FOSTER Understanding Zoning

    69/99

    System LED Power LED

    Leaving Air Sensor

    24V. Transformer

    HVAC Unit

    Zone

    Dampers

    Zone

    Thermostats

    Set-Up Jumpers

    Fan On In Purge

    Fan On In Heat

    Test

    No Sensor

    Jumper

    Single Stage Heat/Cool

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    H32 Zone Control Panel

  • 8/12/2019 2011FOSTER Understanding Zoning

    70/99

    Push-In Wiring Bocks, NO SCREWS!

    Color Coded Terminals

    Three (3) Zone Control Panel

    Single Stage, Two Stage and Heat Pump

    Built-In Dual Fuel Kit

    Compatible with Any Thermostat

    LED Readout for System Status

    Remote Leaving Air Sensor Control

    Outdoor Air Sensor for HP Fossil Fuel

    Built-In Stage Timer Eliminates Need for Two Stage

    Thermostats

    DIP Switches Configuration

    Reliable Relay Output for Dampers and HVAC

    Equipment

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    MZS4 Zone Control Panel

  • 8/12/2019 2011FOSTER Understanding Zoning

    71/99

    MZS4 Zone Control Panel

    Push-In Wiring Bocks, NO SCREWS!

    Color Coded TerminalsFour (4) Zone Control Panel

    Expandable with Zone Adder Panels

    Single, Two Stage and Heat Pump

    Compatible with Any Thermostat

    LED Readout for System Status

    Remote Leaving Air Sensor Control

    Built-In Stage Timer Eliminates Needfor Two Stage Thermostats

    8 DIP Switches for ConfigurationReliable Relay Output for Dampersand HVAC Equipment

    Built-In Re-settable Fuse

    March 23-25, 2011Landsdowne, VA2004-11 ZONEFIRST

    MZS4 Panel Wiring Diagram

  • 8/12/2019 2011FOSTER Understanding Zoning

    72/99

    Outdoor Unit

    HVAC Equipment

    Indoor Unit

    T24 VOLT 40VA

    TRANSFORMER

    ZONE1

    ZPS SENSOR

    Z

    ONE2

    ZONE3

    ZONE4

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Zone Thermostat and Damper Connections

  • 8/12/2019 2011FOSTER Understanding Zoning

    73/99

    Thermostat Connections

    FAN - G

    COOL - Y

    TRANSFORMER - R

    HEAT - W

    TRANSFORMER - C

    Damper Connections2 Wires

    Single Stage and Two Stage 4/5 Wires

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Heat Pump Thermostat and Damper Connections

  • 8/12/2019 2011FOSTER Understanding Zoning

    74/99

    Heat Pump Thermostat Connections

    Emergency Heat* E

    Fan - G

    Cool - Y

    Trans.(Hot) R

    Reversing Valve - O

    Trans(Common) - C

    Damper Connections

    2 Wires

    *Emergency Heat Termiinal only makes on a call for Emergency Heat and will lock out compressor. Do not use thermostats with W 2/E as second stage call will also lock out compressor.

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    HVAC Equipment Connections - Single and Two Stage

  • 8/12/2019 2011FOSTER Understanding Zoning

    75/99

    HVAC Equipment Connections Single and Two Stage

    Instead of wiring to the thermostat, wire tothe zone panel just like the thermostat.

    Second Stage Heat

    First Stage Heat

    24V Transformer

    Fan Relay

    First Stage Cooling

    Second Stage Cooling

    Outdoor Unit

    HVAC Equipment

    Indoor Unit

    Common

    March 23-25, 2011Landsdowne, VA2004-11 ZONEFIRST

    Heat Pump Equipment Connections

  • 8/12/2019 2011FOSTER Understanding Zoning

    76/99

    Instead of wiring to the thermostat, wire to the zone panel just

    like the thermostat.

    W - Second Stage Heating Relay

    E - Emergency Heating Relay

    R - 24 Volt Transformer (Hot)

    G - Fan Relay

    O- Reversing Valve Relay - Cool

    Y - Compressor Relay

    B - Reversing Valve Relay - Heator

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Zone Plenum Sensor Model ZPS

  • 8/12/2019 2011FOSTER Understanding Zoning

    77/99

    Protects HVAC Equipment from over-heating or over-cooling when only a few zones are calling and/or air is

    being bypass through the return. Leaving Air Sensor is placed in supply air plenum, out of line of sight of heat

    exchanger, evaporator coil and before radiant strips on a heat pump.

    Adjustable setting on heating from 100F to 170F on panel.

    Cooling is fixed at 45F.

    NO SENSOR JUMPER When not using this sensor place jumper across these

    pins. If jumper is not in place System LED will flash and HVAC Unit will not

    activate.

    Adjustable Heating Limit Dial

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    24 Volt Transformer

  • 8/12/2019 2011FOSTER Understanding Zoning

    78/99

    24 Volt, 40VA Transformer, Model T24

    C - Common

    R - Hot

    A separate 24 Volt, AC, 40VA Transformer is recommended to power the zone

    panel, thermostats and damper motors.

    The re-settable fuse protects the board and transformer from accidental shorts. If

    the board is not operating, check for to see if HOT. If it is remove all wiring to

    the circuit board and apply only the 24 Volt Transformer to the panel. The panel

    power LED will illuminate showing the board is operating and now to check for

    the short, somewhere.

    Re-settable Fuse

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    MZA2 Zone Adder

  • 8/12/2019 2011FOSTER Understanding Zoning

    79/99

    Using a RJ11 (six conductor) telephone jack cord connects the main panel

    to the adder panel. Adds two zones to the MZS4 Zone Panel. Up to 3

    MZA2 Panels can be used to add up to 6 zones for a total of 10 zones.

    Each Zone Adder panel comes with a 7 foot cable.

    To additional Zone

    Adder Panels.

    MZS4 Panel

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    The Advantage

  • 8/12/2019 2011FOSTER Understanding Zoning

    80/99

    The Advantage

    EZ Wir ing

    Plug and Play

    Color Coded Push-In

    Thermostat Connections

    Plug-In Damper Motors

    Using RJ11 Telephone Wire

    Simplifies Wiring

    Wire in a Fraction of the time.

    Eliminates Mistakes

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Plug Play Zone DampersSide Mount

  • 8/12/2019 2011FOSTER Understanding Zoning

    81/99

    Damper LED GREENOpen

    RED- Closed

    25 Modular Cord

    Included w/each Damper

    Dual Motor Connections

    Daisy Chain up to 10 Dampers/Zone

    Retro-Round Damper - RRP

    Bottom Mount

    ZDBP

    ZDSP

    Outlet Damper

    OZD

    Round Damper

    RDP

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Its Too Complicated?

  • 8/12/2019 2011FOSTER Understanding Zoning

    82/99

    Zone 1 Supply Air Duct Zone 2 Supply Air Duct

    T T

    4/5 Wire Thermostats for each Zone

    2 Wire Dampers for each Zone

    24V-40VA Transformer to Power Control

    Panel and Dampers4 Wires (Y-G-R-W) to HVAC Unit

    By-Pass Damper from Supply to Return

    Zone Plenum Sensor in Plenum

    ZONE

    THERMOSTATZONE

    THERMOSTAT

    ZONE DAMPERS

    TRANSFORMER

    CONTROL

    PANEL

    Zone Plenum

    Sensor

    Return

    AirDuct

    By-Pass Damper

    BLOWER

    HEAT EXCHANGER

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Its Too Complicated?

  • 8/12/2019 2011FOSTER Understanding Zoning

    83/99

    p

    Damper Installation:

    1. Cut a 4 slot in the side of the duct.

    2. Slide the Damper in.

    3. Secure with self-tapping screws provided.

    The rest is simple wiring, using standard thermostat wire:

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Troubleshooting Zoning

  • 8/12/2019 2011FOSTER Understanding Zoning

    84/99

    What can/does go wrong?

    Wiring Disconnected or changed

    Damper Motors Wear OutVolt/Ohm Meter to Check

    All 24 Volts

    Three Basic Problems

    Heat/Cooling wont come on

    Heat/Cooling wont shut off

    Dampers not Operating

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Troubleshooting Zoning -

  • 8/12/2019 2011FOSTER Understanding Zoning

    85/99

    Troubleshooting Zoning Damper

    March 23-25, 2011Landsdowne, VA2004-11 ZONEFIRST

    ON24VAC

    Damper PowerCheck 24V across COMOPENCheck 24V across COM-CLOSECheck 24V at PanelCheck 24V at Damper

    Troubleshooting Zoning -

  • 8/12/2019 2011FOSTER Understanding Zoning

    86/99

    Thermostat

    March 23-25, 2011Landsdowne, VA2004-11 ZONEFIRST

    ON24VAC

    Ohm Thermostat Wires at Panel (non-powered)Disconnect Wires from PanelOhm R-W Heat CallOhm R-G Fan CallOhm R-Y Cool Call

    Check 24V from Thermostat (Powered Stat)Common must be wired to C on Panel

    All other wires disconnected.Check 24VAC - C-W Heat CallCheck 24VAC - C-Y Cool CallCheck 24VAC - C-G Heat CallCheck 24VAC - C-E Em.Heat Call (Heat PumpStat)

    Jumper Panel Thermostat TerminalsR-W Heat Call - RED System LEDR-Y Cool CallGreen System LEDR-G Fan CallYellow System LED

    Troubleshooting Zoning - HVAC

  • 8/12/2019 2011FOSTER Understanding Zoning

    87/99

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    ON0 Ohms

    Check Panel Terminals

    Ohm R-W Heat Call

    Ohm R-G Fan Call

    Ohm R-Y Cool Call

    Insure 24VAC at Panel

    Outdoor Unit

    Indoor Unit

    Zoning vs. Multiple Units

  • 8/12/2019 2011FOSTER Understanding Zoning

    88/99

    g p

    Try this exercise using two units:

    Two Units vs. One Unit and Zoning

    2 - 50,000 BTU 80% Furnace @ $565.00 each =$1,030.00

    Vs.

    1 100,000 BTU 80% Furnace @ $800.00 each = 20% $avings

    And

    2 24,000 BTU 13 SEER Condensers (w/coil/tubing) @ $1,324 ea. = $2,648.00

    Vs.1 42,000 BTU 14.5 SEER Condenser (w/coil/tubing/)@ $2,346 = 11% $avings

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Zoning vs. Multiple Units

  • 8/12/2019 2011FOSTER Understanding Zoning

    89/99

    g p

    Try this exercise using two units:

    Two Units vs. One Unit and Zoning

    2 - 50,000 BTU 80% Furnace @ $565.00 each =$1,030.00

    Vs.

    1 100,000 BTU 80% Furnace @ $800.00 each = 20% $avings

    And

    2 24,000 BTU 13 SEER Condensers (w/coil/tubing) @ $1,324 ea. = $2,648.00

    Vs.1 42,000 BTU 14.5 SEER Condenser (w/coil/tubing/)@ $2,346 = 11% $avings

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Zoning vs. Two Units = $avings

  • 8/12/2019 2011FOSTER Understanding Zoning

    90/99

    g g

    Two Units vs. One High Efficiency Unit with Zoning2 80% AFUE (50,000 BTU) 1,030.00 vs. 1 80% AFUE (100,000 BTU) 800.002 13 SEER 2 Tons A/C 2,648.00 vs. 1 14.5 SEER 3.5 Tons A/C 2,346.00

    1 2 Zone System 514.503,678.00 3,660.50

    Plus other incidental savings of:Only one electrical disconnect.Only one condensing unit pad.

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Downs izing and Eff ic iency

  • 8/12/2019 2011FOSTER Understanding Zoning

    91/99

    Downs izing and Eff ic iency

    Ratings

    Take a typical home that requires 100,000 BTU.

    Zone house using 2 separate furnaces.

    Typically use 2-50,000BTU Furnaces.

    Being that cost is often a driver in the HVAC Businessthe units are minimum efficiency.

    2 x 50,000 BTU = 100,000 BTU x 80%AFUE = 80,000 BTU

    1 x 90,000 BTU = 90,000 BTU x 90%AFUE = 81,000 BTU

    March 23-25, 2011Landsdowne, VA

    2004-11 ZONEFIRST

    Cooling Efficiency and Zoning

  • 8/12/2019 2011FOSTER Understanding Zoning

    92/99

    Use a sample home sized for 4 Tons of A/C.

    Zone house using 2 separate air conditioners.

    Typically 2-2 Ton A/C. Being that cost is often a driver in the HVAC Business

    the units are minimum efficiency.

    2 x 24,000 BTU = 48,000 BTU x 13 SEER $336.00

    1 x 42,000 BTU = 42,000 BTU x 16 SEER $491.00

    -12% 6,000 BTU +20% SEER

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Zoning and Efficiency

  • 8/12/2019 2011FOSTER Understanding Zoning

    93/99

    Two Smaller

    Lower Efficiency Units

    One Larger

    Higher Efficiency Unit

    and ZONING

    50MBTU

    80% AFUE

    50MBTU

    80% AFUE

    2 Ton

    13SEER

    2 Ton

    13SEER

    3.5 Ton

    14.5 SEER

    Two UnitsTotal

    80MBTU

    4 Tons

    One Unit

    with ZONINGTotal

    81MBTU

    Same Capacity

    10% More Efficient

    3.5 Tons

    23% More Efficient

    12.5% Less Capacity

    vs.

    90MBTU

    90% AFUE

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Zoning Heat Pumps

  • 8/12/2019 2011FOSTER Understanding Zoning

    94/99

    Every Heat Pump should be ZonedSized for Cooling Load

    Limited Heating Output

    Undersized for Heating Loads

    Require back-up on colder temps

    Zoning Heats Single Zones

    Capacity of Heat Pump = Zone Load

    Lessens the need for back-up heat

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    Zoning and Efficiency Ratings

  • 8/12/2019 2011FOSTER Understanding Zoning

    95/99

    g y g

    Try this exercise with a contractor using two units in

    new construction:Review the previous two slides using the brand

    equipment he uses.

    After calculating using one unit vs. two, ask to see hisequipment pricing and price out the 2 lower efficiencyunits vs. the one higher efficiency unit.

    Compare the costs and add in a Zoning System.

    Find the difference. In many cases the equipment costmay be the same or somewhat less for the single unit. Thedifference can be used to pay for the zoning system.

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    How do you get zoning sales??

  • 8/12/2019 2011FOSTER Understanding Zoning

    96/99

    y g g

    Quote it on every job.

    Hydronic Systems its Automatically Included.

    Point out that they may have zoning in their car,but not in their home.

    Sell the benefit of added comfort.

    Sell the benefits of 25% Energy Savings, the systemwill pay back for itself.

    Sell the benefit of convenience of being able tocontrol the temperature where you are.

    Its just common sense, like a light switch!

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

  • 8/12/2019 2011FOSTER Understanding Zoning

    97/99

    Zoning Information

  • 8/12/2019 2011FOSTER Understanding Zoning

    98/99

    Product Catalog Design Guide

    www.zonefirst.com

    1-877-FIRSTZONE

    March 23-25, 2011 Landsdowne, VA

    2004-11 ZONEFIRST

    By-Pass Calculator CD Catalog

    Q & A

  • 8/12/2019 2011FOSTER Understanding Zoning

    99/99

    Q & AQuestionsand Answers