Model: AS601U 1D Fixed barcode Scanner SPECIFICATIONS STEP1 - CHECK HARDWARE STEP2 - CONNECT TO HOST STEP3 - POSITION SCANNER STEP4 - INSTALL SOFTWARE UTILITY DIMENSION SCANNING RANGE Light source 525nm visible green LED 635nm visible red LED Scan rate 200 scans/sec Sensor 2500 pixels CCD sensor Resolution 4mil/ 0.1mm PCS 30% Width of Field 140mm (13Mil Code39) Depth of Field 4 Mil Code39: 60 - 85mm 5 Mil Code39: 50 - 90mm 10 Mil Code39: 60 - 180mm 15 Mil Code39: 60 - 250mm 13 Mil UPC/EAN: 60 - 180mm Dimension W56 x L41 x H20 mm Housing ABS (Housing), PC (Back Cover) Weight 120g ± 10g Cable Length 90cm/35.4in (Fixed Cable) Interface RS232, USB HID Voltage 5VDC±5% Working Current < 200mA Standby Current < 140mA Operating Temp.  -10 to 55˚C (14˚F to 131˚F) Storage Temp. -20 to 65˚C (-4˚F to 149˚F) Ambient Light 70,000 lux Drop Durability 1.5M Sealing IP55 Symbologies All major 1D barcodes incl. GS1 Databar Top View Front View Pin Signal 1 2 3 +5VCC Data - Data + 4 GND RS232 (D-Sub 9 Female): USB (Type A Male): Pin Signal 2 3 5 7 8 TXD(Out) RXD(In) GND CTS(In) RTS(Out) USB Hardware USB Connection RS232 Hardware RS232 Connection 1. Connect the scanner to the host. 2. The scanner is powered by the USB connection. 3. Data will be sent as HID keyboard input. 2. Pitch the scanner at a minimum of ±5˚ to avoid specular reflection. 1. Maximum Scan Angle: Skew ±45˚, Pitch ±60˚, Tilt±40˚ Skew ±45˚ Pitch ±60˚ Tilt±40˚ Based on different hardware & configuration method, there are 2 types of software utility: 1. EZU Software - works with USB interface scanner and supports configuration barcodes 2. BEO Software - works with RS232 interface scanner and supports command operation Both are available for download from Arkscan Website : 1. Connect the scanner to the host. 2. Connect a power adapter(sold separately) to the RS232 connector’s DC Jack as external power supply. 3. Data will be sent serially over RS232, with communication settings of 9600-8-N-1 4 Mil Code39: 60 - 85mm 5 Mil Code39: 50 - 90mm 10 Mil Code39: 60 - 180mm 15 Mil Code39: 60 - 250mm Unit: MM Auto-sensing Area Barcode Scanning Area Quick Guide 56mm 41mm 20mm Side View Scanner (Side View) Barcode 1D Fixed Barcode Scanner Quick Guide (Rev 1) http://www.arkscan.com For technical support, please contact us by Email: [email protected] Tel: 1-212-655-4423

1D Fixed barcode Scanner Quick Guide - ARKSCAN, LLC · 1. Maximum Scan Angle: Skew ±45˚, Pitch ±60˚, Tilt ±40˚ Skew±45˚ Pitch ±60˚ Tilt ±40˚ Based on di˝erent hardware

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1D Fixed barcode Scanner Quick Guide - ARKSCAN, LLC · 1. Maximum Scan Angle: Skew ±45˚, Pitch ±60˚, Tilt ±40˚ Skew±45˚ Pitch ±60˚ Tilt ±40˚ Based on di˝erent hardware

Model: AS601U

1D Fixed barcode Scanner

SPECIFICATIONS

STEP1 - CHECK HARDWARE STEP2 - CONNECT TO HOST STEP3 - POSITION SCANNER STEP4 - INSTALL SOFTWARE UTILITY

DIMENSION SCANNING RANGELight source 525nm visible green LED

635nm visible red LEDScan rate 200 scans/secSensor 2500 pixels CCD sensorResolution 4mil/ 0.1mmPCS 30%Width of Field 140mm (13Mil Code39)Depth of Field 4 Mil Code39: 60 - 85mm

5 Mil Code39: 50 - 90mm 10 Mil Code39: 60 - 180mm 15 Mil Code39: 60 - 250mm 13 Mil UPC/EAN: 60 - 180mm

Dimension W56 x L41 x H20 mmHousing ABS (Housing), PC (Back Cover)Weight 120g ± 10gCable Length 90cm/35.4in (Fixed Cable)Interface RS232, USB HIDVoltage 5VDC±5%Working Current < 200mAStandby Current < 140mAOperating Temp.  -10 to 55˚C (14˚F to 131˚F)Storage Temp. -20 to 65˚C (-4˚F to 149˚F)Ambient Light 70,000 luxDrop Durability 1.5MSealing IP55Symbologies All major 1D barcodes incl. GS1 Databar

Top View

Front View

Pin Signal123

+5VCCData -Data +

4 GND

RS232 (D-Sub 9 Female):

USB (Type A Male):

Pin Signal23578

TXD(Out)RXD(In)GND

CTS(In)RTS(Out)

USB Hardware USB Connection

RS232 Hardware RS232 Connection

1. Connect the scanner to the host.2. The scanner is powered by the USB connection.3. Data will be sent as HID keyboard input.

2. Pitch the scanner at a minimum of ±5˚ to avoid specular re�ection.

1. Maximum Scan Angle: Skew ±45˚, Pitch ±60˚, Tilt ±40˚

Skew ±45˚

Pitch ±60˚

Tilt ±40˚

Based on di�erent hardware & con�guration method, there are 2 types of software utility:

1. EZU Software - works with USB interface scanner and supports con�guration barcodes

2. BEO Software - works with RS232 interface scanner and supports command operation

Both are available for download from Arkscan Website :

1. Connect the scanner to the host.2. Connect a power adapter(sold separately) to the RS232 connector’s DC Jack as external power supply.3. Data will be sent serially over RS232, with communication settings of 9600-8-N-1

4 M

il Co

de39

: 60

- 85m

m5

Mil

Code

39: 5

0 - 9

0mm

10 M

il Co

de39

: 60

- 180

mm

15 M

il Co

de39

: 60

- 250

mm

Unit: MM

Auto-sensing Area

Barcode Scanning Area

Quick Guide

56mm

41mm

20mmSide View

Scanner(Side View)

Barcode

1D Fixed Barcode Scanner Quick Guide (Rev 1)

http://www.arkscan.com

For technical support, please contact us byEmail: [email protected]

Tel: 1-212-655-4423

Page 2: 1D Fixed barcode Scanner Quick Guide - ARKSCAN, LLC · 1. Maximum Scan Angle: Skew ±45˚, Pitch ±60˚, Tilt ±40˚ Skew±45˚ Pitch ±60˚ Tilt ±40˚ Based on di˝erent hardware

ST

EP

5 -

CO

NN

EC

T

ST

EP

5 -

CO

NN

EC

T

ST

EP

6 -

CO

NF

IGU

RE

TH

E S

CA

NN

ER

ST

EP

6 -

CO

NF

IGU

RE

TH

E S

CA

NN

ER

AD

VA

NC

ED

- C

ON

FIG

UR

AT

ION

BA

RC

OD

ES

AD

VA

NC

ED

- C

OM

MA

ND

OP

ER

AT

ION

EZ

U S

OF

TW

AR

E C

ON

FIG

UR

AT

ION

(U

SB

)

BE

O S

OF

TW

AR

E C

ON

FIG

UR

AT

ION

(R

S2

32

)

1. R

igh

t-cl

ick

on

th

e

ico

n o

n t

he

de

skto

p a

nd

tic

k

Ru

n t

his

pro

gra

m a

s a

n a

dm

inis

tra

tor”

in t

he

po

p-u

p

m

en

u.

2. D

ou

ble

-clic

k ic

on

on

th

e d

esk

top

to

lau

nch

th

e

p

rog

ram

.

3. I

n C

om

mu

nic

ati

on

Se

ttin

g w

ind

ow

, se

lect

“F

ixe

d”

as

g

en

re a

nd

“U

SB

” a

s in

terf

ace

. Clic

k [S

av

e H

om

e(H

)]

t

o c

on

tin

ue

.

1. C

lick

on

ic

on

on

th

e t

oo

lba

r to

re

trie

ve

sca

nn

er’

s

p

ara

me

ters

.

2. D

ou

ble

-clic

k o

n t

he

ite

ms

you

wa

nt

to e

dit

an

d t

he

n p

ress

[

En

ter]

to

sa

ve

ch

an

ge

s.

1. C

lick

on

ic

on

on

th

e t

oo

lba

r to

ge

ne

rate

co

n�

gu

rati

on

b

arc

od

es.

2. S

can

nin

g t

he

co

n�

gu

rati

on

ba

rco

de

s fr

om

to

p t

o b

ott

om

a

llo

ws

you

to

clo

ne

th

e s

ett

ing

s to

oth

er

sca

nn

ers

ea

sily

.

3.

Cli

ck o

n

ico

n o

n t

he

to

olb

ar

to u

pd

ate

sca

nn

er’

s

p

ara

me

ters

.

4. C

lick

on

ic

on

on

th

e t

oo

lba

r if

yo

u w

an

t to

sa

ve

c

urr

en

t co

n�

gu

rati

on

s fo

r la

ter

use

.

Ez

Uti

lity

Ez

Uti

lity

1. R

igh

t-cl

ick

on

th

e

ico

n o

n t

he

de

skto

p a

nd

tic

k

Ru

n t

his

pro

gra

m a

s a

n a

dm

inis

tra

tor”

in t

he

po

p-u

p

m

en

u.

2. D

ou

ble

-clic

k ic

on

on

th

e d

esk

top

to

lau

nch

th

e

p

rog

ram

.

3. C

lick

on

ic

on

on

th

e t

oo

lba

r, s

et

96

00

-8-N

-1 a

nd

C

OM

1 a

s co

mm

un

ica

tio

n s

ett

ing

s. C

lick

[Sa

ve

Ho

me

(H)]

t

o c

on

tin

ue

.

BE

O

BE

O1

. Clic

k o

n

ico

n o

n t

he

to

olb

ar

to r

etr

iev

e s

can

ne

r’s

p

ara

me

ters

.

2. D

ou

ble

-clic

k o

n t

he

ite

ms

you

wa

nt

to e

dit

an

d t

he

n p

ress

[

En

ter]

to

sa

ve

ch

an

ge

s.

1. P

ress

[F

1]

in t

he

pro

gra

m t

o a

cce

ss h

elp

�le

.

2. U

nd

er

Te

st W

ind

ow

>

ch

ap

ter

i

s fu

ll li

st o

f co

mm

an

ds

all

ow

ing

yo

u t

o c

on

tro

l th

e s

can

ne

r

b

y co

mm

an

d s

trin

gs.

3. F

or

exa

mp

le, i

f yo

u w

an

t to

co

n�

gu

re t

he

sca

nn

er

to

S

eri

al T

rig

ge

r M

od

e (

i.e. a

re

ad

ing

mo

de

th

at

en

ab

les

the

s

can

ne

r to

be

tri

gg

ere

d b

y so

ftw

are

co

mm

an

d),

sim

ply

s

en

d b

elo

w c

om

ma

nd

str

ing

in A

SC

II t

o t

he

ho

st:

{MC

01

WT

6}

4. T

he

sca

nn

er

will

en

ter

Se

ria

l Tri

gg

er

Mo

de

, in

wh

ich

t

he

sca

nn

er

can

be

tri

gg

ere

d b

y se

nd

ing

be

low

AS

CII

c

om

ma

nd

str

ing

:

{ }

<--

curl

y b

rack

ets

wit

h a

sp

ace

in b

etw

ee

n

6. T

he

sca

nn

er

will

be

gin

to

sca

n b

arc

od

e.

*No

te: s

eri

al t

rig

ge

r ch

ara

cte

rs “{

}”

are

co

n�

gu

rab

le.

3.

Cli

ck o

n

ico

n o

n t

he

to

olb

ar

to u

pd

ate

sca

nn

er’

s

p

ara

me

ters

.

4. C

lick

on

ic

on

on

th

e t

oo

lba

r if

yo

u w

an

t to

sa

ve

c

urr

en

t co

n�

gu

rati

on

s fo

r la

ter

use

.