Bulletin 193/592Model EC5
E3 Plus Electronic
Overload Relay with
Voltage Protection and
Energy Monitoring
Customer Presentation
8/13/2019 193-ec5external-120127081657-phpapp02
2/29
Copyright 2009 Rockwell Automation, Inc. All rights reserved. 2
The E3 Plus Electronic Overload Relay with Voltage Protection
and Energy Monitoring provides you with enhanced motorprotection and motor energy consumption information Enhanced Protection
Current Protection
Voltage Protection
Power Protection
Advanced Diagnostics
Voltage Metering
Energy Metering
Additional Features
Trip History
Warning History
Snapshot Record
6 Digital Inputs
E3 Status Object (Object Class 0x375)
E3 Plus with Voltage Protection & EnergyMonitoring
8/13/2019 193-ec5external-120127081657-phpapp02
3/29
Copyright 2009 Rockwell Automation, Inc. All rights reserved. 3
Enhanced Protection
Current Protection
Voltage Protection
Power Protection
Advanced Diagnostics
Voltage Metering
Energy Metering
Additional Features
Trip History
Warning History
Snapshot Record
6 Digital Inputs
E3 Status Object (Object Class 0x375)
E3 Plus with Voltage Protection & EnergyMonitoring
8/13/2019 193-ec5external-120127081657-phpapp02
4/29
Copyright 2009 Rockwell Automation, Inc. All rights reserved. 4
Current Protection The E3 Plus with Voltage Protection and
Energy Monitoring helps protect yourelectric motor investment by preventing
damage from the following events:
Thermal Overload
Phase Loss Jam Warning
Stall
Under Load
Current Unbalance
Ground Fault Current
Ground Fault Current Filtering for
High Resistance Ground Systems
8/13/2019 193-ec5external-120127081657-phpapp02
5/29
Copyright 2009 Rockwell Automation, Inc. All rights reserved. 5
Thermal Overload
The E3 Plus Model EC5 helps protect your
electric motor from consuming more electriccurrent than its nameplate rating which can be
caused by:
Excessive load
Incorrectly sized motor
Low incoming voltage Damaged equipment
The trip class of the motor is selectablebetween 5 and 30 Trip class represents the maximum trip time in seconds
when the motor consumes 720% of the Full Load
Amperes (FLA) rating of the electric motor %Thermal Capacity Utilization (%TCU) can be
monitored to continuously view the thermal statusof the electric motor
8/13/2019 193-ec5external-120127081657-phpapp02
6/29
Copyright 2009 Rockwell Automation, Inc. All rights reserved. 6
Phase Loss
The E3 Plus Model EC5 helps
protect your electric motor whenone phase of power is lost
causing the remaining phases to
consume more electric current
Phase loss is typically caused by: Blown fuse
Loose wire
Damaged contactor contacts
Phase loss is a leading cause of motor failure!
8/13/2019 193-ec5external-120127081657-phpapp02
7/29
Copyright 2009 Rockwell Automation, Inc. All rights reserved. 7
Jam, Stall, & Underload
The E3 Plus Model EC5 helps provide these protection functions to
ensure the safe operation of your electric motor or machine: Jam protection
Prevents an electric motor from running when
a sudden rise in electrical current
consumption occurs during its normal running
operation
Stall protection
Prevents an electric motor from running when
an extended amount of electrical current is
consumed during its starting sequence
Underload protection
Disables an electric motor when a sudden
drop in electrical current occurs indicating a
possible mechanical malfunction
8/13/2019 193-ec5external-120127081657-phpapp02
8/29
Copyright 2009 Rockwell Automation, Inc. All rights reserved. 8
Current Imbalance
The E3 Plus Model EC5 can help
protect against the unequalconsumption of electrical current
on each of the three phases for
your electric motor
Current imbalance protection canbe used to prevent electric motor
damage from:
Imbalance in the voltage supply
Unequal motor winding impedance
Long and varying cable lengths
8/13/2019 193-ec5external-120127081657-phpapp02
9/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 9
Ground Fault
The E3 Plus Model EC5 has the capability to
monitor for short circuits or current leakage toground and provide equipment level protection(20mA5A)
Low levels of ground fault current can rise veryquickly causing damage to the electric motor ifnot caught early
The E3 Plus Model EC5 can monitor groundfault current for:
Solidly grounded systems
High resistance grounded systems
Ground Fault Current Filtering option for High
Resistance Ground Systems to preventnuisance trips
It is important to catch ground faults at the leakage stage!
8/13/2019 193-ec5external-120127081657-phpapp02
10/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 10
AvailableExternal Ground FaultCurrent Transformers
Catalog
Number
Inner
Diameter
Max Wire
Size
3-Phase
Current
Rating
NEMA
Contactor
IEC
Contactor
193-CBCT1 20 mm (1) #8 Awg 45A Size 001 C9C37
193-CBCT2 40 mm (1) #2 Awg 90A Size 003 C9C85
193-CBCT3 65 mm (1) 250MCM 180A Size 4 D180
193-CBCT4 85 mm (2) 350 MCM 420A Size 5 D420
8/13/2019 193-ec5external-120127081657-phpapp02
11/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 11
E3 Plus with Voltage Protection & EnergyMonitoring
Enhanced Protection
Current Protection Voltage Protection
Power Protection
Advanced Diagnostics
Voltage Metering
Energy Metering
Additional Features
Trip History
Warning History
Snapshot Record
6 Digital Inputs
E3 Status Object (Object Class 0x375)
8/13/2019 193-ec5external-120127081657-phpapp02
12/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 12
Voltage Protection
The E3 Plus with Voltage Protection and
Energy Monitoring helps you to protectagainst the following voltage issues:
Under Voltage
Over Voltage
Phase Failure Voltage Unbalance
Phase Rotation Mismatch
Under Frequency
Over Frequency
Protection on the Line Side of the Contactor
8/13/2019 193-ec5external-120127081657-phpapp02
13/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 13
Supported Voltage Systems
The E3 Plus Model EC5 can be used on the following voltage systems:
Catalog Number 193-EC5ZZ
Delta without Potential Transformers
Delta with Potential Transformers
Wye with or without Potential Transformers
Open Delta with Potential Transformers
Single Phase with or without Potential Transformers
All Other Catalog Numbers
Delta without Potential Transformers
Wye with or without Potential Transformers
Single Phase with or without Potential Transformers
Supports direct connections up to 600 VAC(690 VAC IEC)
E3 Pl i h V l P i & E
8/13/2019 193-ec5external-120127081657-phpapp02
14/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 14
E3 Plus with Voltage Protection & EnergyMonitoring
Enhanced Protection
Current Protection Voltage Protection
Power Protection
Advanced Diagnostics
Voltage Metering
Energy Metering
Additional Features
Trip History
Warning History
Snapshot Record
6 Digital Inputs
E3 Status Object (Object Class 0x375)
8/13/2019 193-ec5external-120127081657-phpapp02
15/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 15
Power Protection
To address power quality issues that
could occur due to a specific application,the E3 Plus Electronic Overload Relay
with Voltage Protection and Energy
Monitoring also provides you with the
following power based protection : Real Power (kW)
Reactive Power (kVAR)
Apparent Power (kVA)
Power Factor (PF)
Leading
Lagging
E3 Pl ith V lt P t ti & E
8/13/2019 193-ec5external-120127081657-phpapp02
16/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 16
E3 Plus with Voltage Protection & EnergyMonitoring
Enhanced Protection
Current Protection Voltage Protection
Power Protection
Advanced Diagnostics
Voltage Metering
Energy Metering
Additional Features
Trip History
Warning History
Snapshot Record
6 Digital Inputs
E3 Status Object (Object Class 0x375)
8/13/2019 193-ec5external-120127081657-phpapp02
17/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 17
Advanced Diagnostics
The E3 Plus Electronic Overload Relay not only helps protect your
electric motor investment, but it can proactively assist in maintaining theelectric motor by limiting: Number of starts
Operating hours
The E3 Plus Electronic Overload Relay can also help provide diagnosticand metering information to help you understand the consumptionpatterns for the motor or process by providing: RMS current
Percentage of full load current (%FLA)
Current imbalance
Thermal Capacity Utilization (%TCU)
Trip log
Warning log
8/13/2019 193-ec5external-120127081657-phpapp02
18/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 18
Energy Diagnostics To address energy usage
concerns, the E3 Plus Electronic
Overload Relay with Voltage
Protection and Energy Monitoring
provides you with the following
energy diagnostic information: Real Energy (kWh)
Reactive Energy (kVARh)
Apparent Energy (kVAh)
kW Demand kVAR Demand
kVA Demand
8/13/2019 193-ec5external-120127081657-phpapp02
19/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 19
Energy Diagnostics The E3 Plus Model EC5 can
be included in your energymanagement system
Helps identify which motors
contribute to the monthly peak
demand and power factor lineitems on a utility bill
Helps to verify energy reduction
initiatives
Monitoring consumption patterns and adjusting manufacturing
procedures helps to use electricity more efficiently!
E3 Pl s ith Voltage Protection & Energ
8/13/2019 193-ec5external-120127081657-phpapp02
20/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 20
E3 Plus with Voltage Protection & EnergyMonitoring
Enhanced Protection
Current Protection Voltage Protection
Power Protection
Advanced Diagnostics
Voltage Metering
Energy Metering
Additional Features
Trip History
Warning History
Snapshot Record
6 Digital Inputs
E3 Status Object (Object Class 0x375)
8/13/2019 193-ec5external-120127081657-phpapp02
21/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 21
Historical Logs
The E3 Plus Model EC5 internally
records the last five trips and last fivewarnings
Trip History - Selectively record trip events
Warning History - Selectively recordwarning events
Snapshot RecordRecords 12 real-timeparameters at the time of the trip event
Your maintenance personnel can use
the historical logsto minimize down
time during an unplanned event
Trip History
Warning History
Snapshot Record
8/13/2019 193-ec5external-120127081657-phpapp02
22/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 22
Inputs & Outputs
The E3 Plus Model EC5 offers direct
control capabilities by offeringdiscreet inputs and outputs in addition
to the overload trip relay
6 Inputs
2 Outputs The E3 Plus Model EC5 also provides
discreet outputs that can be used for:
Remotely starting a motor
Indicating a fault or warning
Two speed motor control
Logical discreet control
DeviceLogix enabled
8/13/2019 193-ec5external-120127081657-phpapp02
23/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 23
New E3 Status Object
The new E3 Status Object (Object Class 0x375) provides a
more efficient means to read data from an E3 Plus ElectronicOverload Relay
8/13/2019 193-ec5external-120127081657-phpapp02
24/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 24
DeviceNet Configuration Terminal
The DeviceNet Configuration Terminal (Cat. No.
193-DNCT) is an optional device that providesusers the capability to configure and view data
for any DeviceNet component including the E3
Plus Electronic Overload Relays
You can perform these functions locally on aDeviceNet network:
Parameter monitoring
Parameter editing
Storage of device configuration data
Network who
Display network diagnostics
Editing DeviceLogix programs
Trend parameters
8/13/2019 193-ec5external-120127081657-phpapp02
25/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 25
E3 Plus Model EC5 Catalog Number Scheme
Inputs Outputs PTC Dlogix HT Voltage
193/592-EC1 2 1
193/592-EC2 4 2 Internal 15A
193/592-EC3 4 2 External 20mA5A * 193-EC4 4 2 External 20mA5A *
193/592-EC5 6 2 External 20mA5A *
Ground Fault
8/13/2019 193-ec5external-120127081657-phpapp02
26/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 26
E3 Plus Accessories
8/13/2019 193-ec5external-120127081657-phpapp02
27/29Copyright 2009 Rockwell Automation, Inc. All rights reserved. 27
E3 Plus Model EC5 Renewal Parts
E3 Plus Replacement Overload Relay 193-NREC5ZZ
E3 Plus Replacement Voltage input Module 193-NVEC5VIM
E3 Plus Replacement Connectors 193-NCEC5CNT
E3 Plus with Voltage Protection & Energy
8/13/2019 193-ec5external-120127081657-phpapp02
28/29
Copyright 2009 Rockwell Automation, Inc. All rights reserved. 28
E3 Plus with Voltage Protection & EnergyMonitoring
The E3 Plus Electronic Overload Relay with Voltage Protection
and Energy Monitoring provides your with enhanced motorprotection and motor energy consumption information Enhanced Protection
Current Protection
Voltage Protection
Power Protection Advanced Diagnostics
Voltage Metering
Energy Metering
Additional Features
Trip History
Warning History
Snapshot Record
6 Digital Inputs
E3 Status Object (Object Class 0x375)
8/13/2019 193-ec5external-120127081657-phpapp02
29/29
Copyright 2009 Rockwell Automation, Inc. All r ights reserved.
Bulletin 193/592Model EC5
E3 Plus Electronic
Overload Relay with
Voltage Protection and
Energy Monitoring