35
Installation Notice 1 93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr ALL RIGHT RESERVED

157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

Embed Size (px)

DESCRIPTION

LIFT DMG

Citation preview

Page 1: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

Installation Notice

1 93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 2: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

2

2

3

4

1

OPERATING PANELS AND ACCESSORIES

SHAFTMACHINE ROOM

TOP OF CAR

1.1) Installation 5

1.2) Motor connections 6

1.3) Temporary operations 8

2.1) Mountuing Top of car box 10

2.2) Installation of travelling cable 11

2.3) Connection of inspection panel 14

2.4) Connection of cabin doors 15

2.5) Installation of positioning system 16

2.6) Installazion of deceleration limit switches AGB/AGH 18

2.7) Installation of inspection limit switch and final limit switch 19

2.8) Installation of door zone / relevelling 20

2.9) Accessories 21

3.1) Mounting of shaft conduit 22

3.2) Safety chain 23

3.3) Shaft illumination 24

4.1) Car Operating Panel 25

4.2) Hall panels 26

4.3) Voice Synthesizer and Emergency telephone 29

5 Use of "PLAYPAD" programming module 30

6 Normal service mode 31

7 Use of control panel on Machine Room Less controller 34

8 Duplex Lift 35

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 3: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

PARTS IDENTIFICATIONS

cod. QSM.C___Machine room wirings

3

cod. Q09F7_Inverter kit

cod. QTC.TOCB_Standard TOC box

cod. QTC. PMCSInspection box for TOC(with safety operation button)

P3

cod. QVA.ENC + QVA.CORD_Encoder counting kit+ rope 60 / 120 mt.

cod. QVA.BANDFlags for optical system

cod. QTC.P3FFOOptical counting kit

cod. QVA.DR120Hanging band for flags

cod. QTC.P3FFMMagnetic counting kit

cod. QSM. PMEEmergency operation box

P3

cod. QTC.CALMagnets for counting kit

cod. QTC.FFCSwitch supports kit

cod. QVA.STHH Supports

cod. QTC.P3FCRMMagnetic deceleration switches

cod. QTC.P3FCR1-2Mechanical deceleration switches

cod. QTC.P3CTOCcod. QTC.P3CTOC2Top of car wiring kit

cod. QVA.P3SAPPrewired alarm siren

cod. QVA.BALUTop of car edges kit

cod. QVA.GARDCar toe guard kit

cod. QTC.P3PSCEmergency stop 2nd door

cod. QTC.P3PMCInspection box for TOC

cod. QSM.P3PMPTemporary operation box

cod. QTC.P3FTCDoor cellule kit

cod. QTC.LLCS2PLoad weighing kit

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 4: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

PARTS IDENTIFCATIONS

4

cod. QVA.CP__8 poles cable for hall panels

cod. QVA.CAUX8 / 14Serial position indicators cable

cod. QVA.37P437 poles cable for car panel

cod. QVA.P3PSC3Stop + 220V plug for pit+ shaft illumination command

cod. QSM.DTUMain power switch box

cod. QTC.P3RZP1Levelling and door zone kit

cod. QTC.P3RZP2Door Zone kit

cod. QVA.EXHFinal limit switch kit (traction/hyd indirect)

cod. QVA.EXEFinal limit switch kit (traction/hyd direct)

cod. QVA.CANShaft conduit

cod. QVA.SF_Safety chain

cod. QVA.P3PSC1Pit stop

cod. QVA.P3PSC2Stop + 220V plug for pit

cod. QVA.C16P20-25-30-35-40-45-50-55-6020 ÷ 60 mt travelling cables

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 5: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

1) MACHINE ROOM1.1) - FIXING THE CONTROLLER

5

1

MA

CH

INE

RO

OM

Supportingclamp

1 2 3

4 5 6

Cabine Back plate

Unease the 4 screws and remove the metal backplate from the cabinet

Caution: perform all wirings and connections before hanging the cabinet to the back plate

Fix the back plate to the wall Use the 4 screws to fix the cabinet to the back plate

RACEWAY

BATTERIES

+/-24V

+/-12V

7

600 mm

320 mm

H

H D

720840

1040

660780985

D

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 6: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

1.2) - CONNECTION OF THE MOTOR1.2.1) - TRACTION CONTROLLERS

(2 speeds / )VVVF / MRL

Cable for brake 3G_ - cod. Q09F7_ / QSM.C2V_

Cable for temperature sensor 3G_ - cod. QSM.CVF_ / QSM.C2V_

Screened cable for motore 4G_ (solo VVVF) - Cable for motor 4G_ - cod. QSM.C2V_

cod. Q09F7_

Conduit

MAINPOWER

BOX

Car light powersupply cable 3G1,5

Controller powersupply cable 4G_

MOTOR

Screened cables for braking resistor 3G2,5 (VVVF only) - cod. Q09F7_

Brake resistors(VVVF only)

6

1

MA

CH

INE

RO

OM

PLAYBOARD III

cod. QSM.CVF_QSM.C2V_

L2 L3 U V W PA PBL1NF11 F12 L4 L5

L2 L3 U V W X YL1N F11 F12 L4 L5Z

VVVF

2 speeds

cod. QSM.CVF_

cod. QSM.C2V_

cod. QSM.CVF_

cod. Q09F7_

CONNECT GROUND HERE

L2 L3 U V W PA PBL1NF11F12 L4 L5

MRL

cod. QSM.CVF_

cod. QSM.CVF_

cod. Q09F7_

PB IIIMRL

With VVVF/MRL controllers, connect the earth braid through the dedicated ring.

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 7: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

1.2.2) - HYDRAULIC CONTROLLERS

(Star triangle / Soft starter / Direct)

Pump motor cable 4G_cod. QSM.CHS_ / QSM.CHD_

Valves cable 3G1,5 + thermic sensor 3G1,5cod. QSM.CHS_ / QSM.CHD_

MAIN POWER

BOX

Star Triangle

Soft starterDirect

L2 L3 U1 V1 W1 W2 U2L1N L4 L5V2

L2 L3 U V WL1NL4 L5

cod. QSM.CHD_

cod. QSM.CHS_

7

PLAYBOARD III

PUMP

CONNECT GROUND HERE

Conduit

Car light powersupply cable 3G1,5

Controller powersupply cable 4G_

cod. QSM.CHS_QSM.CHD_

Star-Triangle cable 4G_cod. QSM.CHS_

1

MA

CH

INE

RO

OM

F1 F2 F4 F5

F1 F2 F4 F5

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 8: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

ENTER ESC

X2

ENTERITDE

FR

EN

X3

ENTER

ENTER

X2

ENTER ESC

X2

1.3) - TEMPORARY OPERATIONS1.3.1) - CONNECTIONS AND PROGRAMMING

SA

FE

TY

BO

AR

D(S

EC

)

REVMR

CA

BIN

INT

ER

FAC

E B

OA

RD

B(I

NT

PIT

B)

Check correct languagesetting

>>> OFF >>> ON (Switch off and then power on supply to start temporary operations)

>>> ON (Switch on power supply)

5

6

SV1

1

2

MAIN POWER

BOX3

MAIN POWER

BOX7

8

4

PLAYPAD MODULE

PROGRAMMING

1

MA

CH

INE

RO

OM

cod. QSM.P3PMP

PLAYBOARD III

PLAYBOARD III

PB IIIMRL

PB IIIMRL

________________Floor X 12:30:56

- PLAYBOARD -

Floor X 12:30:56 Floor X 12:30:56Language ?

Fr *En* De It

________________Floor X 12:30:56

< Faults >Floor X 12:30:56

Floor X 12:30:56< Configuration >

Floor X 12:30:56

Temporary OperationsYes

< Configuration >

No faults

Floor X 12:30:56< Faults >

Faults :

Floor X 12:30:56

Temporary Operations< Configuration >

FAI FAS

SE2 SE3 SE4 SE6 AGB AGH DEF ZP

ENTER ESC

L4 L5

page 6/7

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 9: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

L2 L3 U V WL1N

M3

3-phasepower supply

HydraulicPumpMotor

Thermicsensor

Up / Down(signals 24V)

Up / Down2nd contact

(safety)

F1 F2 F4 F5

Valves

Dow

n

Hi S

peed

L2 L3 U V W PA PB F11 F12L1N

M3

3-phasepower supply

TractionMotor

Thermicsensor

Up / Down(signals 24V)

Up / Down2nd contact

(safety)

Motorbrake

Brakeresistance

L2 L3 U V W X Y Z F11 F12L1N

M3

TractionMotor

Thermicsensor

Up / Down(signals 24V)

Up / Down2nd contact

(safety)

FIM

FIM Motorbrake

L2 L3 U1 V1 W1 W2 U2 V2 F1 F2 F4 F5L1N

M3

3-phasepower supply

HydraulicPumpMotor

Valves

Dow

n ru

n

Hi s

peed

Tria

ngle Thermic

sensorUp / Down

(signals 24V)Up / Down2nd contact

(safety)

1.3.2) - ELECTRICAL SCHEMATICS (TEMPORARY OPERATIONS)

HYDRAULIC(Star Triangle)

TRACTION(2 speeds - monophased brake)

TRACTION(MRL - VVVF - open or closed loop - monophased brake)

HYDRAULIC(Direct)

Temporary operationbox

Temporary operationbox

Temporary operationbox

Temporary operationbox

9

1

MA

CH

INE

RO

OM

1 6

SEC

SV1 SV1

STOP

1 6

SEC

SV1 SV1

STOP

1 6

SEC

SV1 SV1

STOP

1 6

SEC

SV1 SV1

STOP

INT

TH1 GNDTHM

INT

TH1 GNDTHM

INT

TH1 GNDTHM

INT

TH1 GNDTHM

REVMRREMREDGND REV1

REVMRREMREDGND REV1

REVMRREMREDGND REV1

REVMRREMREDGND REV1

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 10: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

10

TOP

OF

CA

R

2

2) TOP OF CABIN2.1) - FIXING OF TOC BOX

FIXING

3

1

0

5

4

2

7

6

TOC

Place the TOC box 1mt away from walls with doors.

EN 81-72

1 MTTOC

OPENING

cod. QTC.TOCB1AE1 access, traction lifts

cod. QTC.TOCB1AH1 access, hydraulic lifts

cod. QTC.TOCB2AE2 accesses, traction lifts

cod. QTC.TOCB2AH2 accesses, hydraulic lifts

X41

3

2ZOOM

TOC box

416300

141

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 11: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

½ RUN

Clamp fixedto the car

Clamp fixedin the shaft

Travelling cable16+16 polescod. QVA.C16P_

PLAYBOARDController

TOC

2.2) - INSTALLATION OF TRAVELLING CABLE2.2.1) - FIXING OF TRAVELLING CABLE IN THE SHAFT

11

TOP

OF

CA

R

2

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 12: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

3

1

0

5

4

2

7

6

TOC

SC1

L1

PT1

ALIM

CAN

TEL

TOC

BO

AR

D P

TOC

BO

AR

D S

2.2.2) - CONNECTION OF TRAVELLING CABLE TO THE TOP OF CAR BOX

12

PT1

L1

SC1

ALIM

CAN

TEL

Door A power supply and control

Car illumination and retiring ramp, 230V

Car safeties

Power supply 24V + other

CAN serial line

Amigo II Emergency Telephone

Contact Description

1

2

TOP

OF

CA

R

2

PL

AY

BO

AR

D C

ON

TR

OL

LE

R

Ground connectionon TOC box

16 POLES

SPARE

PL

AY

BO

AR

D C

ON

TR

OL

LE

R

16 POLES

16+16 POLEScod. QVA.C16P20 (20mt)

25 (25mt)30 (30mt)35 (35mt)40 (40mt)45 (45mt)50 (50mt)55 (55mt)60 (60mt)

RU

N / W

AR

NIN

GFA

ILOn duty

RUN FAIL

ON Out of service

Error (please check connections)

OFF

Description

1

1 1

ON

OFF = shut down ON = continous blinking= single blinking1

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 13: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

L1

PT1

ALIM

CAN

TEL

SC1

1

3

4

2

2.2.3) - CONNECTION OF TRAVELLING CABLE TO CONTROLLER

13

TOP

OF

CA

R

2

DO

OR

+ L

IGH

T B

OA

RD

(PT

R T

RI / L

UX

CA

M)

CA

R IN

TE

RFA

CE

BO

AR

D A

(IN

T P

IT A

)C

AR

INT

ER

FAC

E B

OA

RD

B(I

NT

PIT

B)

SA

FE

TY

BO

AR

D(S

EC

)

PB IIIMRL

PLAYBOARD III

TO

C B

OA

RD

S

16 POLES

SPARE

16 POLES

TO

C B

OA

RD

S

Ground connection

16+16 POLEScod. QVA.C16P20 (20mt)

25 (25mt)30 (30mt)35 (35mt)40 (40mt)45 (45mt)50 (50mt)55 (55mt)60 (60mt)

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 14: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

3

1

0

5

4

2

7

6

TOC

2.3) - CONNECTION OF STANDALONE INSPECTION BOX (only if NOT integrated TOC box)

RV

REV

14

1

2

TOC

BO

AR

D P

TOC

BO

AR

D S

P

P

RV

REV

220V Power supply

Ispection (safety)

Ispection (signals)

Contact Description

TOP

OF

CA

R

2

STANDALONEINSPECTION BOX

cod. QTC.P3PMC or QTC.P3PMCS

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 15: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

15

LIG

HT

CU

RTA

INS

DO

OR

CO

NTA

CT

OP

EN

/CLO

SE

LIM

IT S

IWT

HC

ES

+ D

OO

R S

HO

CK

DOOR OPERATOR + BRAKEOR DOOR INJECTION

2nd door contact

Door operator and brake or injection 2nd door

3

1

0

5

4

2

7

6

TOC

2.4) - CONNECTION OF CAR DOORS

CELA

CELB

CPCB

CPCA

2nd door open/close contacts + door shock contact

FCPA

FCPB

DA

TOC BOARD P

TOC BOARD S

DB

1

2nd door light curtains

TOP

OF

CA

R

2

2

3

4

cod. QTC.P3CTOC

3

cod. QTC.P3FTC

cod. QTC.P3CTOC2

QTC.P3CTOC + 2nd door

Door cellule kit

21 4 § 2.9

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 16: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

4

3

5

7

6

8

B

Pulley

Pulley

TOP OF CAR

Place the spring tensioner and brackets according to the space available in the shaft.

1

2

A

C

Guide rail

2.5) - INSTALLATION OF POSITIONING SYSTEM 2.5.1) - ROPE AND PULLEY ENCODER (cod. QVA.ENC)

YES (IP51) NO

Pulley

The pulley embedding the Encoder must be installed in the top of the shaft or in the pit, close to the machine room.

SHAFT

SHAFT

16

TOP

OF

CA

R

2

PLAYBOARD III

SHAFTENCODER

WIR

E T

ER

MIN

AL

S

INT

ER

FAC

E B

OA

RD

1

9

PB IIIMRL

3

SH

AF

T

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 17: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

TOC BOARD S

2.5.2) - OPTICAL / MAGNETIC POSITIONING SYSTEM (FAI / FAS)

FAIS

TOC

Hanging band supportcod. QTC.P3FFO

1

TOC

Magnetic switches supportcod. QTC.P3FFM

Magnetcod. QTC.CAL

Magnetic switchescod. QTC.P3FFM

OPTICALsystem

MAGNETICsystem

17

1

2

3

AGB

AGH

C

floor 0

C

floor 1

upper floor

2

B

FASFAI

B

FASFAI

Place flags / magnets on extreme floors so that C reaches at least ¼ of slowdown distance B

Minumum distance C

1

3

4 5

2

1

3

3

4

2

1

3

4

2

1

5

5

4 5

TOP

OF

CA

R

2

FASFAI

The contact is closed and Leds are lit when the switches ARE NOT in front of flags/magnet

Hanging band supportcod. QTC.P3FFO

Flagscod. QVA.BAND

1

Hanging bandcod. QVA.DR1202

3

Switch support cod. QTC.P3FFO

Optical switchcod. QTC.P3FFO

Intermediate supportcod. QTC.P3FFO_STF4

from 0 to 5 floors = no supportfrom 6 to 10 floors = 1 supportfrom 11 to 14 floors = 2 suppportsHas to be positioned in place of one of the flags.

5

6

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 18: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

2.6) - INSTALLATION OF TOP/BOTTOM DECELERATION LIMIT SWITCHES (AGB/AGH)

Magnet AGHcod. QTC.P3FCRM

Bottom deceleration limit switch (AGB)

Top deceleration limit switch (AGH)

TOC

MAGNETICAGB/AGH

MECHANICALAGB/AGH

Top deceleration limit switch cam (AGH)

cod. QTC.P3FCR1-2

Bottom deceleration limit switch cam (AGB)

cod. QTC.P3FCR1-2

Top deceleration limit switch (AGH)

Bottom deceleration limit switch(AGB)

“U” supportcod. QTC.FFC

“H” supportcod. QVA.STH

18

AGH AGB

cod.QTC.P3FCRM

cod.QTC.P3FCR1-2

TOP

OF

CA

R

2

Magnet AGBcod. QTC.P3FCRM

TOC

WHITE side

BLACK side TOC BOARD S

AGBAGH

Leds are lighted when the contact gets closed

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 19: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

2.7) - INSTALLATION OF INSPECTION AND TOP/BOTTOM FINAL LIMIT SWITCHES

TOC

TOC BOARD S

TOC BOARD P

Top final limit switch cam

Top inspection limit switch cam

Bottom inspection limit switch cam

Bottom final limit switch cam

Inspection limit switchcod. QVA.FCIA1 (con scivolo alto)cod. QVA.FCIA2 (con scivolo alto e basso)

Final Limit switchcod. QVA.EXE (imp. Fune / oleo diretto)cod. QVA.EXH (imp. oleo in taglia)

19

HCS Safety contact for final limit NC Contact

FCOSafety contact for final limit NO Contact

CFRM

Top inspection limit switch NC contact

CFRD

Bottom inspection limit switch NC contact

Bridge the contactNOT used

“U” supportcod. QTC.FFC

TOP

OF

CA

R

2

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 20: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

2.8) - INSTALLATION OF DOOR ZONE AND RELEVELLING

TOC BOARD S

ISO

ZP

30

cm

TOC

Relevelling

30 cm magnet sharp at floorcod. QTC.CAL

20

TOP

OF

CA

R

2

cod. QTC.P3RZP2Magnetic sensor for door zone unlocking signal

cod. QTC.P3RZP1Magnetic sensors for car relevelling and door zone unlocking signal

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 21: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

DB

PT2

RETIRING RAMP

2nd ACCESS STOP

CAM

CSTCB

CPAR

LUM

LOAD WEIGHING

SIRESIREN

CABIN LIGHT

SAFETY GEAR

LLEC

TRAP DOOR

CTRA

2.9) - ACCESSORIES

1

2

3

4

5

6

7

3

1

0

5

4

2

7

6

TOC

LLEC

21

CBAN(NO)

CBAR(NO)

HANDRAIL

8

RE

TIR

ING

CA

R T

OE

GU

AR

D

CGRE9

CABIN 700

mm

TOP

OF

CA

R

2

MECHANICAL SWITCH AND RAMP FOR RETIRING CAR TOE GUARD

Normal - CBAN(contact close)

Inspection - CBAR(contact close)

cod. QTC.P3CTOC

2nd access stop kit

cod. QTC.P3PSC

cod. QTC.LLCS2P

cod. QVA.P3SAP

cod. QVA.BALU

cod. QVA.GARD

3

2

7

8

9

Weighing kit

Siren kit

Handrail kit

Retiring car toe guard kit

1 5 64 § 2.4

POMC

1

0

CABIN'SFIREFIGHTERS' KEY

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 22: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

3) SHAFT3.1) - MOUNTING OF SHAFT CONDUIT (for shaft wirings)

BA C

Ø 8 mm

2 M

T

Each floor

1

2

3

3

SH

AF

T

22

Shaft conduitcod. QVA.CAN

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 23: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

2

3.2) - INSTALLATION OF SAFETY CHAIN

SV1

GRAY (LOCK)

BLACK ( )PRELIMINARY

BROWN (STOP / TENSION DEV.CONT.)

SM1

WHITE (SPEED LIMITER)

TENSIONDEVICE

CONTACT

STOP

MachineRoom

Floor N

Pit

Floor N+1

23

SAFETYBOARD(SEC)

SM1 = machine room safeties SV1 = shaft safeties

PRELIMINARY

LOCK

3

SH

AF

T

PB IIIMRL

PLAYBOARD III

cod. QVA.P3PSC2cod. QVA.P3PSC1

Safety chaincod. QVA.S_

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 24: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

3.3) - SHAFT ILLUMINATION

Shaft illumination switch

Main Power boxcod. QSM.DTU

MACHINE ROOM

SHAFT

PIT

24

3

SH

AF

T

MACHINE ROOM ILLUMINATION

SHAFT ILLUMINATION

Prewired lamp

Fascetta e tassello

Shaft box with STOP button + + shaft illumination commandcod. QVA.P3PSC3

Pit Socket

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 25: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

4) CAR OPERATING PANELS AND ACCESSORIES4.1) - INSTALLATION OF CAR PANEL

OP

ER

AT

ING

PAN

EL

S A

ND

AC

CE

SS

OR

IES

4

25

3

1

0

5

4

2

7

6

TOC

TOC

BO

AR

D S

Car interface board B

37 poles flat cablecod. QVA.37P4

NCNOC NCNOC

DECORAZIONEDECORAZIONE

ATTENZIONEL'ascensore scende

in emergenza

ATTENZIONEApertura automaticaNon toccare le porte

640 Kg 8 Pers.VIETATO L’USO DELL’ASCENSORE

AI MINORI DI ANNI 12 NON ACCOMPAGNATI

RGF12236963/2004 DPR399WB637/200400168

Car interface board A

Screws

A B C

LE

1 and 2 = ON-> zone A illuminated3 = ON-> zone B (12/24V)illuminated

5 = ON -> buzzer activated whenoverload signal. is illuminated

DMCPIT

4 = ON-> zone C (12/24V)illuminated

ALARM MSG TXT/BUZ. MODE TXT MSG

TEL J SERVICE

CALL0,2,4,6,8,10,12

ON1

SERIAL LINE 4321

CALL0,1,2,3,4,5,6

CALL1,3,5,7,9,11,13

5 6GONG

5

7 8

DMCPIT

1ON 2

1 1

1 11

DMCPIT

ALARM MSG TXT/BUZ. MODE TXT MSG

TEL J SERVICE

CALL0,2,4,6,8,10,12

ON1

SERIAL LINE 4321

CALL0,1,2,3,4,5,6

CALL1,3,5,7,9,11,13

5 6GONG

5

7 8

DMCPIT

1ON 2

11

1 1

1

DMCPIT

IDC 10pAlarm + LE (emergency light)

12

ON

12

ON Common +12V for signalization

alarm sent and alarm received

Signalization alarm sent and alarmreceived with independent commons(non DMG telephones only)

ALARMMSG

SERIALLINE

TEL

JSERVICE

TXTMSG

JST 3p - Power supply (12/24V) • 1=GND, 2=+24V, 3=+12V

IDC 10p - D43-45-56-67 Position indicators

JST 7p - Caruso 2 voice synthesizer(1=+12V, 2=+24V, 3=GND, 4=LINE-, 5=LINE+)

IDC 10p - Amigo 2 Emergency phone

IDC 10pTexts, buzzer + LE

JST 2p - LE (emergency light)(1=LE, 2=GND)

JST 2p - D45 buzzer(1=+24V, 2=BUZ-)

1 = zone C+2 = zone B+3 = zone A-4 = zone A+5 = Communication established (-)6 = Communication established (+)7 = Alarm sent (-)8 = Alarm sent (+)(5,6,7,8 = non DMG telephones only)

IDC 10pService push-buttons

JST 4p - Gong (1=Gong M, 2=Gong D, 3=+24V, 4=REF)

Ø 1 mm MAX

JST 2p - Calls activation

JST 2p - Priority key

IDC 10p - Singol push-buttons column

IDC 10p - DX push-buttons column(2 columns)

IDC 10p - SX push-buttons column(2 columns)

NO

YES

ON1

5

Position indicator texts switch

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 26: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

PB IIIMRL

4.2) - INSTALLATION OF HALL PANELS4.2.1) - PARALLEL COMMUNICATION

DISPLAY

F7F6F5F4F3F2F1F0

F0

F1

FN

26

INT

ER

FAC

E B

OA

RD

B(I

NT

PIT

B)

FLO

OR

S IN

TE

RFA

CE

BO

AR

D(C

AL

L P

IT)

Floor "0"

Floor "1"

Floor "N°"

FN

RJ45 cable (8 poles)cod. QVA.CP_

Hall indicators cablecod. QVA.CAUX_

OP

ER

AT

ING

PAN

EL

S A

ND

AC

CE

SS

OR

IES

4

PLAYBOARD III

ON

12

12/24V dc

ON

1 2

12/24V dc

Only if next direction arrows are present

1

0

Present only on Firefighters' systems.

Led FAIL ON = Short circuit on the pushbuttons' lines

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 27: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

3,5

mt

3,5

mt

3,5

mt

3,5

mt

10

mt

10

mt

10 poles twisted flat cablecod. QVA.C10P10B

BDU

BDU

BDU

PB IIIMRL

4.2.2) - SERIAL LINK

27

Floor "0"

Floor "1"

Floor "2"

OP

ER

AT

ING

PAN

EL

S A

ND

AC

CE

SS

OR

IES

4

BDU

INT

ER

FAC

E B

OA

RD

B(I

NT

PIT

B)

PLAYBOARD III

Kit BDUQVA.BDU4S

10 poles flat cable10 poles flat cable

BDU

ON

12

12/24V dc

ON

1 2

12/24V dc

TO UPPERFLOOR

TO LOWERFLOOR

1

0

Present only on Firefighters' systems.

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 28: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

ON = power up

OFF = shut down

ON = continous blinking

N° = N° time blinking

Legend

BDU

TO LOWERFLOOR BDU

AUXILIARY POWER

SERIAL POSITION INDICATOROUTPUT

BDU SERIAL IN

BDU SERIAL OUT

BDU INTERCONNECTIONFOR MULTIPLEX LIFT

(§ 8)

BDU

28

4.2.3) - BDU PROGRAMMING PROCEDURE

INT

ER

FAC

E B

OA

RD

B(I

NT

PIT

B)

PLAYBOARD III

1

2

3

4

FAI FAS

SE2 SE3 SE4 SE6 AGB AGH DEF ZP

ENTER ESC

5

Floor X 12:30:56

ConfigurationCar SER / Fl. BDU

< Configuration >Playboard

details

§ 3.5

Check on the controller that the configuration using BDUs has been selected.

Use the car button to call and position the lift at the floor corresponding to the BDU you want to program.

Press the floor call button (downward arrow) for at least 10 seconds. Verify that when the button is released it also stops blinking.From now the BDU is programmed.

AL

IM A

UX

In case of malfunction, check LEDs status and start the reset sequence pressing the reset button for at least 3 seconds. RESET push-button ( ≥3 sec.)

10 sec.10 sec.

On duty

RUNFAIL

ON

OFF OFF Out of service (not powered / broken power supplier)

OFFService suspended(follow the BDU programming procedure)

OFF

ON OFF Out of service (micro fault / not programmed)

Description

ON Out of service (serial line communication)

ON Out of service (undefined BDU address)

ONOut of service (Car at the floor with unvalidor unprogrammed BDU)

1

3

1

2

Out of service(serial line communication)

Out of service(undefined BDU address)

Out of service (Car at the floorwith unvalid or unprogrammed BDU)3

1

2

On dutyOFF

Connect all the BDUs on the various floors (§ 4.2.2).If provided, connect the auxiliary power as shown in the diagram beside.

Led FAIL

Led RUN

NOTE: In case of multiplex lift (§ 8) the procedure must be repeated for each installation (all others must be switched off during the procedure)

OP

ER

AT

ING

PAN

EL

S A

ND

AC

CE

SS

OR

IES

4

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 29: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

29

OP

ER

AT

ING

PAN

EL

S A

ND

AC

CE

SS

OR

IES

4For detailed connection instructions and device programming, check the CARUSO and/or AMIGO user’s manuals

CARUSO Voice synthesizer(ESY2000IT)

+-

S AUDIO IN

1 2 3 4 5 6 8 97 PREWIRED

ETSA2SLD

+-

SAUDIO IN

CAR DIGITAL DEVICE

1 2 3 4 5 6 8 97

ATT. ON/OFF

ADDRESS

PREWIRED

ETSA2CSD

4.3) - (4 device configuration)VOICE SYNTHESIZER AND AMIGO 2 EMERGENCY PHONE

MACHINE ROOM

PIT

ATTENZIONEL'ascensore scende

in emergenza

ATTENZIONEApertura automatica

Non toccare le porte

54

32

10

DMCPIT

+-

S AUDIO IN

1 2 3 4 5 6 8 97 PREWIRED

ETSA2SLD

- S +

AMIGO 2 Emergency telephone(ETSA2MRS)

Digital slave device(ETSA2SLD)

Digital slave device(ETSA2SLD)

Car digital slave device(ETSA2CSD)

TOC Board S

DERDER TELTEL

CA

R IN

TE

RFA

CE

BO

AR

D B

(IN

T P

IT B

)

TEL

TEL MR

Rechargeable battery - 12V Pb

- S +

Machine Room Kit(ETSKSM2)

QVA.C16P__

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 30: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

FAI FAS

SE2 SE3 SE4 SE6 AGB AGH DEF ZP

ENTER ESC

SAFETY CHAIN STATUS(4 points normally lit)

TOP/BOTTOM SLOWDOWN SWITCHES STATUS

(AGB and AGH)

FAULTS INDICATOR DOOR ZONE INDICATOR

Lits up when car in door zone

MENU NAVIGATION KEYS

POSITION SENSORS STATUSor ENCODER STATUS

(normally lit)

TTL SERIAL LINECONNECTOR

(computer, modem, etc.)

30

AGB AGH

AGB and AGH not active(closed contacts)

AGB AGH

AGB active(open contact)

DEF

OK

DEF

Blinking: Presence of Fault(s)(See list of faults)

SE2 SE3 SE4 SE6

Safety chain closed

SE2 SE3 SE4 SE6

Point 3 of safety chainopen

5) USE OF "PLAYPAD" PROGRAMMING MODULE

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 31: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

REVMR

SV2

PLAYBOARD III

cod. QSM.P3PME

PB IIIMRL

31

NORMALE ISPEZIONE

NORMALE ISPEZIONE

1aWITH EMERGENCY OPERATION BOX

WITHOUT EMERGENCY OPERATION BOX 1b

SV

2 RE

VM

R

SV2 2SV2 3 GND

REV

SA

FE

TY

BO

AR

D(S

EC

)C

AB

IN IN

TE

RFA

CE

BO

AR

D B

(IN

T P

IT B

)

CA

BIN

INT

ER

FAC

E B

OA

RD

B(I

NT

PIT

B)

SA

FE

TY

BO

AR

D(S

EC

)

6) NORMAL SERVICE MODE

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 32: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

32

MAINPOWERSWITCH

>>> OFF >>> ON (Switch off and power on to set the lift in normal service mode)

ENTER

ENTER

X3

ENTER

X2PLAYPAD PROGRAMMINGMODULE

LIFT MOVES TO LOWEST FLOOR

Playboard

details

§ 5

Possible wrong positioning of positioning sensors

Check the error code in the troubleshooting section

AGB AGH DEF ZP AGB AGH DEF ZP

ESC

X2

PLAYBOARD III

PB IIIMRL

LIFT NOT WORKING

LIFT BEYOND FINAL LIMITS

Floor X 12:30:56Resetting

Floor X 12:30:56< Configuration >

Floor X 12:30:56

Temporary OperationsNo

< Configuration >________________Floor X 12:30:56

- PLAYBOARD -

Floor X 12:30:56

FAI FAS

SE2 SE3 SE4 SE6 AGB AGH DEF ZP

ENTER ESC

Set the stopping accuracy (Fine tuning) at each floorSee next page

Perform final system test(check all lift functions)

Set Next Direction Arrows (if present)

Playboard

details

§ 4§ 3.2.2

2

3

4

5

7

6

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 33: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

33

Floor 0 12:30:56<Positioning>Floor Position

4070 mm

CABIN

CABIN

6.1) - SETTING FLOOR STOPPING ACCURACY

withDMG OPTICAL ENCODER

withFAI/FAS OPTICAL/MAGNETIC POSITIONING SYSTEM

Cardirection

Cardirection

FLAGS (Optical positioning system)MAGNETS (Magnetic positioning system)

Playboard III

details

§ 5

Enter the <Positioning> Menu, select the “Floor Position” parameter which indicates the exact position (in mm) of each floor and press [ENTER] to modify it.

From within the cabin, use the PLAYPAD module keys to set the stopping accuracy by increrasing or decreasing the position.

Use the PLAYPAD module on the controller. Alternatively, remove the module from its housing inside the controller, plug it on the “S” card in the Top of Car box through the 9 poles cable (optional) and use it directly inside the cabin.

DecreaseIncrease

ENTER ESC

Floor 0 12:31:40< >PositioningFloor Position

3165 mm

When the correct floor positioning is reached, press [ENTER] to store it.

CARDTOC S

FAI FAS

SE2 SE3 SE4 SE6 AGB AGH DEF ZP

ENTER ESC

PLAYPADFront Back

1

2

3

4

Floor 0 12:30:56<Positioning>Floor Position

4070 mm

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 34: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

7) USE OF CONTROL PANEL ON MACHINE ROOM LESS CONTROLLER

Power supplyCircuit breaker

Emergencyswitch

Main PowerSwitch

LightMain Switch

Shaftillum.switch

220V Socket

Socketsswitch

Shaft illuminationM. Room illumination

Car illumination

34

Overspeed governorcommand

(3 positions, withspring return)

Emergency OperationsControls

TRIPRESET

ISP

NORM EME

UP

DWLIM STOP

TESTTEST

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED

Page 35: 157_93010090.en_q_pitagora-v3_091105-0_en_ed.g

BDUBDU

BDU BDU

2ndcontrol panelif present

8) DUPLEX LIFT

35

PLAYBOARD III PLAYBOARD III

CA

R IN

TE

RFA

CE

BO

AR

D A

(IN

T P

IT A

)C

AR

INT

ER

FAC

E B

OA

RD

B(I

NT

PIT

B)

CA

R IN

TE

RFA

CE

BO

AR

D A

(IN

T P

IT A

)C

AR

INT

ER

FAC

E B

OA

RD

B(I

NT

PIT

B)

Kit BDU QVA.BDU4S

10 poles twisted flat cable (10 mt)cod. QVA.C10P10B

10 poles flat cable (4 mt)

8 poles phone cable (4 mt)

10 poles twisted flat cable (4 mt)

BDU

4 poles JST cablecod. QVA.C04P4BDX

RXRX

TXTX

RXRX

TXTX

93010090.EN__Q_Pitagora-V3_091105-0_EN__ed.g.cdr

ALL RIGHT RESERVED