================================================================================ ================================= Command to get and adjust Priamry CPICH Power (Default is 320) ================================================================================ ================================= RNRST08> get U08-BKK1536-1A pri.* RNRST08> set U08-BKK1536-1A primaryCpichPower 300 ================================================================================ ================================= Command to get and adjust Individualoffset (reccommeded is 0) ================================================================================ ================================= RNRST08> get U08-BKK2874-1A individualoffset.* RNRST08> set U08-BKK2874-1A individualOffset 30 RNRST08> set U08-BKK2874-1A individualOffset -30 ================================================================================ ================================= Command to get and set e-tilt ================================================================================ ================================= BKK1132-U08> get ret elect Result will be shown as below ================================================================================ ================================= MO Attribute Value ================================================================================ ================================= SectorAntenna=3,AuxPlugInUnit=2,RetuDeviceGroup=1,RetDeviceSet=1,RetDevice=1 ele ctricalAntennaTilt 60 SectorAntenna=1,AuxPlugInUnit=2,RetuDeviceGroup=1,RetDeviceSet=1,RetDevice=1 ele ctricalAntennaTilt 40 SectorAntenna=2,AuxPlugInUnit=2,RetuDeviceGroup=1,RetDeviceSet=1,RetDevice=1 ele ctricalAntennaTilt 40 ================================================================================ ================================= BKK1132-U08> set SectorAntenna=1,AuxPlugInUnit=2,RetuDeviceGroup=1,RetDeviceSet= 1,RetDevice=1 electricalAntennaTilt 60 ================================================================================ ================================= Command to get alarm ================================================================================ ================================= mobatch t 500 p 50 RBS.txt lt all;alt;lga --- when u run mobatch it will read from your txt file if you put -p 50 it mean it will open every 50 sites in your list until finish it means it will run every 50 sites at same time -t is the expired time

146129870 Ericsson AMOS Command

Embed Size (px)

DESCRIPTION

Ericsson AMOS commands

Citation preview

Page 1: 146129870 Ericsson AMOS Command

=================================================================================================================Command to get and adjust Priamry CPICH Power (Default is 320)=================================================================================================================

RNRST08> get U08-BKK1536-1A pri.*RNRST08> set U08-BKK1536-1A primaryCpichPower 300

=================================================================================================================Command to get and adjust Individualoffset (reccommeded is 0)=================================================================================================================

RNRST08> get U08-BKK2874-1A individualoffset.*RNRST08> set U08-BKK2874-1A individualOffset 30RNRST08> set U08-BKK2874-1A individualOffset -30

=================================================================================================================Command to get and set e-tilt=================================================================================================================

BKK1132-U08> get ret elect

Result will be shown as below=================================================================================================================MO Attribute Value=================================================================================================================SectorAntenna=3,AuxPlugInUnit=2,RetuDeviceGroup=1,RetDeviceSet=1,RetDevice=1 electricalAntennaTilt 60SectorAntenna=1,AuxPlugInUnit=2,RetuDeviceGroup=1,RetDeviceSet=1,RetDevice=1 electricalAntennaTilt 40SectorAntenna=2,AuxPlugInUnit=2,RetuDeviceGroup=1,RetDeviceSet=1,RetDevice=1 electricalAntennaTilt 40=================================================================================================================

BKK1132-U08> set SectorAntenna=1,AuxPlugInUnit=2,RetuDeviceGroup=1,RetDeviceSet=1,RetDevice=1 electricalAntennaTilt 60

=================================================================================================================Command to get alarm=================================================================================================================

mobatch �t 500 �p 50 RBS.txt �lt all;alt;lga�---when u run mobatchit will read from your txt fileif you put -p 50it mean it will open every 50 sites in your listuntil finishit means it will run every 50 sites at same time-t is the expired time

Page 2: 146129870 Ericsson AMOS Command

after this amount of time (count by second) if there's no response it will closeanyway, not so importantI always put -t quite highbut -p will effect, for node B & simple command you put p high is okbut if run mobatch for RNC& the data u wanna get is hugebetter reduce -pso the server wont be overload

To learn the command you can start with type "h"-----

=================================================================================================================Command to get & Set Primary CPICH power=================================================================================================================RNRST08> get u08-bkk2874.* primarycpich.*=================================================================================================================MO Attribute Value=================================================================================================================UtranCell=U08-BKK2874-2A primaryCpichPower 320UtranCell=U08-BKK2874-2B primaryCpichPower 320UtranCell=U08-BKK2874-2C primaryCpichPower 320UtranCell=U08-BKK2874-1A primaryCpichPower 320UtranCell=U08-BKK2874-1B primaryCpichPower 320UtranCell=U08-BKK2874-1C primaryCpichPower 320=================================================================================================================RNRST08> set u08-bkk2874-2B primarycpichpower 300

=================================================================================================================Command to check whether cell is carring traffic.=================================================================================================================

BKK1352-U08> get radioResult=================================================================================================================1422 NodeBFunction=1,Sector=4,Carrier=1,RadioLinks=1=================================================================================================================RadioLinksId 1noOfRadioLinks 20

=================================================================================================================++++++ Command to check status of cell and channel ++++++++=================================================================================================================

RNRST06> lst u08-bkk1664.* ( this will show adm and op state includding channel status including EUL channel.)

Page 3: 146129870 Ericsson AMOS Command

RNRST06> st u08-bkk1664.* ( this will show only adm and op state )

=================================================================================================================++++++ Command to check & Set admission control ++++++++=================================================================================================================RNSNK11> get BKK1132 sf8adm

130222-10:39:44 10.229.70.14 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/16576=================================================================================================================MO Attribute Value=================================================================================================================UtranCell=U08-BKK1132-1A sf8Adm 8UtranCell=U08-BKK1132-1A sf8AdmUl 8UtranCell=U08-BKK1132-1B sf8Adm 0UtranCell=U08-BKK1132-1B sf8AdmUl 8UtranCell=U08-BKK1132-2B sf8Adm 0UtranCell=U08-BKK1132-2B sf8AdmUl 8UtranCell=U08-BKK1132-2C sf8Adm 0UtranCell=U08-BKK1132-2C sf8AdmUl 4UtranCell=U08-BKK1132-1C sf8Adm 0UtranCell=U08-BKK1132-1C sf8AdmUl 4UtranCell=U08-BKK1132-2A sf8Adm 8UtranCell=U08-BKK1132-2A sf8AdmUl 8=================================================================================================================RNSNK11> set UtranCell=U08-BKK1132-1B sf8Adm 8

130222-10:40:24 10.229.70.14 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/16576Set sf8Adm on following 1 MOs ?===================================================================================17297 RncFunction=1,UtranCell=U08-BKK1132-1B===================================================================================Set sf8Adm on 1 MOs. Are you Sure [y/n] ? y

============================================================================================================ Id MO sf8Adm Result============================================================================================================17297 UtranCell=U08-BKK1132-1B 8 >>> Set.

=================================================================================================================++++++ Command to adjut out sync parameter ++++++++=================================================================================================================

RNRST01> get u08-BKK2942.* noutsyncind

Page 4: 146129870 Ericsson AMOS Command

130226-18:12:59 10.229.66.4 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/18678=================================================================================================================MO Attribute Value=================================================================================================================UtranCell=U08-BKK2942-1B nOutSyncInd 20UtranCell=U08-BKK2942-1C nOutSyncInd 10UtranCell=U08-BKK2942-2A nOutSyncInd 20UtranCell=U08-BKK2942-2B nOutSyncInd 20UtranCell=U08-BKK2942-2C nOutSyncInd 10UtranCell=U08-BKK2942-1A nOutSyncInd 20=================================================================================================================

minPwrMax 0->10 minPwrRl -150 to -120RNRST08

RNRST08> get u08-bkk2874.* minpwrmax

130313-11:15:57 10.229.66.11 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/9950=================================================================================================================MO Attribute Value=================================================================================================================UtranCell=U08-BKK2874-2A minPwrMax 0UtranCell=U08-BKK2874-2B minPwrMax 20UtranCell=U08-BKK2874-2C minPwrMax 20UtranCell=U08-BKK2874-1A minPwrMax 0UtranCell=U08-BKK2874-1B minPwrMax 20UtranCell=U08-BKK2874-1C minPwrMax 20=================================================================================================================Total: 6 MOs

RNRST08> get u08-bkk2874.* minpwrrl

130313-11:16:10 10.229.66.11 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/9950=================================================================================================================MO Attribute Value=================================================================================================================UtranCell=U08-BKK2874-2A minPwrRl -150UtranCell=U08-BKK2874-2A minPwrRlTdd -24UtranCell=U08-BKK2874-2B minPwrRl -150UtranCell=U08-BKK2874-2B minPwrRlTdd -24UtranCell=U08-BKK2874-2C minPwrRl -150UtranCell=U08-BKK2874-2C minPwrRlTdd -24UtranCell=U08-BKK2874-1A minPwrRl -150UtranCell=U08-BKK2874-1A minPwrRlTdd -24UtranCell=U08-BKK2874-1B minPwrRl -150UtranCell=U08-BKK2874-1B minPwrRlTdd -24UtranCell=U08-BKK2874-1C minPwrRl -150UtranCell=U08-BKK2874-1C minPwrRlTdd -24=================================================================================================================Total: 6 MOs

Page 5: 146129870 Ericsson AMOS Command

RNRST08> pmx u08-bkk2874-1B -m 23 -h rabreleasespeech

=================================================================================================================++++++ Command to check VSWR ++++++++=================================================================================================================

BKK2874-U08> lh ru fui get vswr

130325-14:11:04 10.232.12.8 8.0v RBS_NODE_MODEL_N_1_50 stopfile=/tmp/82=============================================================================================$ lhsh 000100/port_0_dev_6 fui get vswr0001p0d6: vswr: 25.3[dB]=============================================================================================$ lhsh 000100/port_1_dev_7 fui get vswr0001p1d7: vswr: 20.4[dB]=============================================================================================$ lhsh 000100/port_2_dev_8 fui get vswr0001p2d8: vswr: 23.8[dB]

RNRST08> h cedr

***************************************************************************************ced[h][r][p] [-m <module(s)>|-c <utrancell>|-r <iublink>] [ | <unix cmds>]***************************************************************************************Print consumption of cell resources and rbs hw (RNC only).

The following COLI commands are run on the module MPs in RNC: - celldata (ced/cedr) --> shows dynamic utrancell data, consumption of air interface resources - hwm (cedh/cedhp/cedhr) --> shows rbs Channel Elements consumption and number of RadioLinks/UEs

Switches: - "r": re-read the data, otherwise, cached data is re-parsed. - "p": prints the CE consumption in percentage (only applicable to "cedh" command). - "h": when the "h" switch is used, the resources consumption values are shown on Iub level, when the "h" switch is not used, they are shown on UtranCell level.

Options: -m <module(s)>: only fetch/parse the data for certain RncModules, e.g. "-m 8" or "-m 1,2,3" -c <utrancell>: only fetch/parse the data for specific UtranCells, e.g. "-c cell304A" (not case sensitive) -r <iublink> : only fetch/parse the data for specific IubLinks, eg. "-r iub_304" (not case sensitive)

The output can be filtered by piping through some unix commands, eg. grep or sor

Page 6: 146129870 Ericsson AMOS Command

t.

Examples:>> ced | grep 0019sp0 --> print all cells configured on CC device 001900/sp0>> ced | sort -k 5 --> print cell data sorted on the fifth field>> cedh -m 8,9,10 --> print CE usage for all sites in modules 8, 9, 10.>> ced -r iub_304 --> print cell data for all cells belonging to IubLink=Iub_304>> cedh -c cell304a --> print CE usage for the site connected to UtranCell=cell304A

Printout format:> ced----------------------------------------------------------------------------------------------------------------------------------------------MOD CELL cid fro ro PwrDl/Adm dlCode ulInt sf8d sf8u sf16d sf16u sf32d sf4u dlASE ulASE HScnt EULs EULns CPMcnt CC_SP---------------------------------------------------------------------------------------------------------------------------------------------- 1 Iub-1-1 1031 0 0 7.0% 75% 6.2% -111.8 0/8 0/8 0/16 0/16 0/32 0/4 0/500 0/500 0/10 1/32 0/100 0/15 1:0019sp1 1 Iub-1-2 1032 1 2 7.0% 75% 6.2% -111.8 0/8 0/8 0/16 0/16 0/32 0/4 0/500 0/500 0/10 4/32 0/100 0/15 1:0021sp1 1 Iub-1-3 1033 2 3 7.0% 75% 22.9% -111.8 1/8 0/8 0/16 1/16 0/32 0/4 39/500 8/500 0/10 3/32 0/100 0/15 1:0019sp1 1 Iub-2-1 1037 6 1 7.0% 75% 24.6% -111.8 1/8 0/8 0/16 2/16 1/32 0/4 53/500 20/500 0/10 0/32 0/100 0/15 1:0019sp1 1 Iub-2-2 1038 7 4 7.0% 75% 10.8% -111.8 0/8 0/8 0/16 2/16 1/32 0/4 12/500 19/500 1/10 0/32 0/100 0/15 8:0023sp1(!)

> cedh-------------------------------------------------------------------------------------------------------------------------------------------MOD GRP IUBLINK fro ro nCell usedCEdl usedCEul gHoCEdl gHoCEul OtherCEdl OtherCEul dlRL ulRL nrUE leakingCellFroIds------------------------------------------------------------------------------------------------------------------------------------------- 1 0 b0157MDN 0 0 3 34/64 98/256 30/64 158/256 29/63 155/253 46 46 46 1 4 b0423MDN 5 2 2 2/64 6/128 62/64 122/128 61/63 120/126 3 3 3 1 8 b0407MDN 8 4 1 8/64 42/256 56/64 214/256 55/63 211/253 15 15 15 1 10 b0106MDN 9 5 3 40/96 125/256 56/96 131/256 55/95 128/253 48 48 49 147

> cedhp-------------------------------------------------------------------------------------------------------------------------------------------MOD GRP IUBLINK fro ro nCell usedCEdl usedCEul gHoCEdl gHoCEul OtherCEdl OtherCEul dlRL ulRL nrUE leakingCellFroIds------------------------------------------------------------------------------------------------------------------------------------------- 1 0 b0157MDN 0 0 3 53.1% 38.3% 46.9% 61.7% 46.0% 61.3% 46 46 46 1 4 b0423MDN 5 2 2 3.1% 4.7% 96.9% 95.3% 96.8% 95.2% 3 3 3 1 8 b0407MDN 8 4 1 12.5% 16.4% 87.5% 83.6% 87.3% 83.4% 15 15 15 1 10 b0106MDN 9 5 3 41.7% 48.8% 58.3% 51.2% 57.9

Page 7: 146129870 Ericsson AMOS Command

% 50.6% 48 48 49 147

The fields in the "ced" printout correspond to the following variables in the "celldata" printout on Module MP: - MOD: RNC Module - cid: cId - fro: cellFroId (facade resource object, a unique id in the node) - ro: cell RO (resource object, a unique id in the module. Same as capsule index.) - PwrDl/PwrAdm: Filtered DL Power / pwrAdm - dlCode: DL Code Allocation Level - ulInt: UL Interference - sf8dl: SF8 RL DL Count / sf8Adm - sf8ul: SF8 RL UL Count / sf8AdmUl - sf16dl: SF16 RL DL Count / sf16Adm - sf16ul: SF16 RL UL Count / sf16AdmUl - sf32dl: SF32 RL DL Count / sf32Adm - sf4ul: SF4 RL UL Count / sf4AdmUl - dlASE: Total ASE DL / aseDlAdm - ulASE: Total ASE UL / aseUlAdm - HScnt: HSDPA UE Count / hsdpaUsersAdm - EULs: EUL UE Count serving / eulServingCellUsersAdm - EULns: EUL UE Count non-serving / eulNonServingCellUsersAdm - EUL2ms: EUL2ms UE Count serving / eulServingCellUsersAdmTti2 - Spch: Speech Only UE Count - CPMcnt: CPM RL Count / compModeAdm - Crn: Crnti allocation count - Hrn: Hrnti allocation count - CC_SP: The RncModule and SPM of the CC device handling the Cell. If the RncModule controlling the CC device is different from the one controlling the cell, an exclamation mark (!) is printed, since this indicates that some performance problems may occur.

The fields in the "cedh" printout correspond to the following variables in the "hwm print grp" printout on Module MP: - MOD: RNC Module - GRP: Cell Group (one or two per IubLink) - IUBLINK: the MO id of the IubLink - fro: the froId of the IubLink (facade resource object id, a unique id in the node) - ro: the RO Id of the IubLink (resource object id, unique in the module. Same as capsule index). - nCell: the number of UtranCells in the Cell Group - usedCEdl/usedCEul: Consumed Credit / Capacity Credit . The number of used CE out of the total amount of available CE. The total amount of available CE is calculated in each RBS, based on the HW capability and the licensed capacity. - gHoCEdl/gHoCEul: Guaranteed, HO (Channel Elements availability for Guaranteed, Handover traffic) - OthrCEdl/OthrCEul: Other (Channel Elements availability for Other traffic) - dlRL, ulRL: number of Radio Links used in the RBS. The two values (downlink and uplink) should always be equal. - nrUE: number of UEs in the RBS. This should be equal to the number of Radio Links. - leakingCellFroIds: the froId of Cells where dlRL, ulRL, nrUE are not equal. This indicates that some resource has not been released properly in the cell. To release the resources in a leaking Cell, the corresponding IubLink MO must be locked and unlocked.

Page 8: 146129870 Ericsson AMOS Command

RNRST08> get bkk2874 ^remotecp

130325-14:50:33 10.229.66.11 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/15980=================================================================================================================MO Attribute Value=================================================================================================================IubLink=Iub_BKK2874-U08 remoteCpIpAddress1 10.233.12.8IubLink=Iub_BKK2874-U08 remoteCpIpAddress2=================================================================================================================Total: 1 MOs

RNRST08> get bkk2874 iub

130325-14:50:41 10.229.66.11 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/15980=================================================================================================================MO Attribute Value=================================================================================================================UtranCell=U08-BKK2874-2A iubLinkRef IubLink=Iub_BKK2874-U08UtranCell=U08-BKK2874-2B iubLinkRef IubLink=Iub_BKK2874-U08UtranCell=U08-BKK2874-2C iubLinkRef IubLink=Iub_BKK2874-U08UtranCell=U08-BKK2874-1A iubLinkRef IubLink=Iub_BKK2874-U08UtranCell=U08-BKK2874-1B iubLinkRef IubLink=Iub_BKK2874-U08UtranCell=U08-BKK2874-1C iubLinkRef IubLink=Iub_BKK2874-U08IubLink=Iub_BKK2874-U08 IubLinkId Iub_BKK2874-U08IubLink=Iub_BKK2874-U08 iubLoadDlThresholdSpeech Struct{5} >>> 1.amr5900 = 100 >>> 2.amr7950 = 100 >>> 3.amr12200 = 100 >>> 4.amrWb8850 = 100 >>> 5.amrWb12650 = 100IubLink=Iub_BKK2874-U08 iubLoadUlThresholdSpeech Struct{5} >>> 1.amr5900 = 100 >>> 2.amr7950 = 100 >>> 3.amr12200 = 100 >>> 4.amrWb8850 = 100 >>> 5.amrWb12650 = 100=================================================================================================================Total: 7 MOs

RNRST08> cedr -r Iub_BKK2874-U08

130325-14:51:02 10.229.66.11 8.0v RNC_NODE_MODEL_M_1_200 stopfile=/tmp/15980

Page 9: 146129870 Ericsson AMOS Command

Trying password from ipdatabase file: /opt/ericsson/amos/moshell/sitefiles/ipdatabase...

Checking available boards on node...

................

.........................Created following board-groups: all, allp, mp, bp, tu, coremp, ommp, scb, sxb, scx, sccpmp, et, etmfg, etmfx, aal2ap, aal2ncc, aal2cpsrc, aal2rh, xp, ranapmp, rnsapmp, mod, modact, modsb, modpdr, mod<sr>, mod<mod>, cc, cc<sr>, cc<mod>, dc, dc<sr>, dc<mod>, pdr, pdr<sr>, pdr<mod>, alld, spb, spb<sr>, spb<mob>.>>> Type "bp" to view available board-groups and "bp <group>" to view group contents.

Created following MO-groups: cc[0-9]dev, dc[0-9]dev, pdr[0-9]dev.>>> Type "mp" to view available MO-groups and "pr <group>" to view group contents.

................................................................................

................................................................................

......................................................................

..put /var/opt/ericsson/amos/moshell_logfiles/OS2133/logs_moshell/tempfiles/20130325-144908_15931/lhCmd15980 /d/usr/lhCmd15980 ... OK....------------------------------------------------------------------------------------------------------------------------------------------- MOD CELL cid fro ro PwrDl/Adm dlCode ulInt sf8d sf8u sf16d sf16u sf32d sf4u dlASE ulASE CPMcn HScnt EULs EULns Eul2 Spch CC_SP-------------------------------------------------------------------------------------------------------------------------------------------1081 U08-BKK2874-1A 6493 465 24 54.6% 75% 38.1% -96.3 0/8 0/8 0/16 2/50 0/32 1/4 19/500 70/500 4/15 22/64 19/32 5/100 4/4 1 13 22 1081:0020sp01081 U08-BKK2874-1B 6501 466 25 31.2% 75% 21.0% -98.2 0/8 0/4 0/16 0/50 0/32 0/0 5.0/500 3.6/500 1/15 6/64 6/32 0/100 3/4 0 1 6 1081:0020sp01081 U08-BKK2874-1C 6502 467 26 33.9% 85% 20.4% -96.2 0/8 0/8 0/16 0/50 0/32 0/4 5.2/500 3.0/500 2/15 3/64 3/32 0/100 1/4 1 5 3 1081:0020sp01081 U08-BKK2874-2A 6503 468 27 45.8% 75% 29.5% -94.7 0/8 0/0 0/16 3/50 0/32 0/0 14/500 21/500 1/15 15/64 12/32 2/100 0/0 3 13 15 1081:0020sp01081 U08-BKK2874-2B 6511 469 28 27.4% 75% 15.3% -101.2 0/8 0/8 0/16 0/50 0/32 0/4 1.2/500 1.8/500 0/15 3/64 3/32 1/100 1/4 0 1 3 1081:0020sp01081 U08-BKK2874-2C 6512 470 29 31.4% 85% 17.0% -94.5 0/8 0/8 0/16 2/50 0/32 0/4 2.6/500 17/500 1/15 4/64 2/32 1/100 0/4 0 2 4 1081:0020sp0------------------------------------------------------------------------------------------------------------------------------------------- Total (6 cells): 0 0 0 7 0 1 47 116.4 9 53 45 9 9 5 35 53-------------------------------------------------------------------------------------------------------------------------------------------