45
13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING To account for behavior of different-length columns, design codes specify several formulae that will best fit the data within the short, intermediate, and long column range. Steel columns Structural steel columns are designed on the basis of formulae proposed by the Structural Stability Research Council (SSRC). F t f ft li d t th f l d Factors of safety are applied to the formulae and adopted as specs for building construction by the American Institute of Steel Construction (AISC) ©2005 Pearson Education South Asia Pte Ltd 1 American Institute of Steel Construction (AISC).

13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

  • Upload
    tranbao

  • View
    216

  • Download
    2

Embed Size (px)

Citation preview

Page 1: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING

• To account for behavior of different-length columns, design codes specify several formulae that will best g yfit the data within the short, intermediate, and long column range.

Steel columns• Structural steel columns are designed on the basis

of formulae proposed by the Structural Stability Research Council (SSRC).F t f f t li d t th f l d• Factors of safety are applied to the formulae and adopted as specs for building construction by the American Institute of Steel Construction (AISC)

©2005 Pearson Education South Asia Pte Ltd 1

American Institute of Steel Construction (AISC).

Page 2: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING

Steel columns• For long columns the Euler formula is used A• For long columns, the Euler formula is used. A

factor of safety F.S. = 23/12 ≈ 1.92 is applied. Thus for design, g ,

( )( )21-13200

/2312

2

2≤≤⎟

⎠⎞

⎜⎝⎛=

rKL

rKL

rKLE

callow

πσ

• Value of slenderness ratio obtained by ( )

2 2EKL π⎞⎛ ( )22-132Yc

Er

KLσπ

=⎟⎠⎞

⎜⎝⎛

©2005 Pearson Education South Asia Pte Ltd 2

Page 3: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING

Steel columns• For slenderness ratio lesser than (KL/r) the design• For slenderness ratio lesser than (KL/r)c, the design

eqn is ( )( )

/1 2

2

⎥⎥⎤

⎢⎢⎡− Y

rKL σ( ) ( )23-13

3

/23

2

⎥⎤

⎢⎡ ⎞⎜⎛

⎥⎤

⎢⎡ ⎞

⎜⎛

⎥⎥⎦⎢

⎢⎣=

Yc

allowKLKL

rKLσ

}88

3

35{ 3

⎥⎥⎥⎥

⎢⎢⎢⎢

⎞⎜⎛

⎠⎜⎝−

⎥⎥⎥

⎢⎢⎢

⎞⎜⎛

⎠⎜⎝+⎟

⎠⎞

⎜⎝⎛

KLr

KLr

88 ⎥⎦

⎢⎣ ⎠

⎞⎜⎝⎛

⎥⎥⎦⎢

⎢⎣ ⎠⎜⎝ cc rr

©2005 Pearson Education South Asia Pte Ltd 3

Page 4: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING

Steel columns

©2005 Pearson Education South Asia Pte Ltd 4

Page 5: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING

Aluminum columns• Design equations are specified by the AluminumDesign equations are specified by the Aluminum

Association, applicable for specific range of slenderness ratios.

• For a common alloy (2014-T6), we have

( )2413120MP195 KL≤≤ ( )

( )25135512MPa62815214

24-13120MPa195

KLKLr

ll

allow

<<⎥⎤

⎢⎡ ⎞

⎜⎛=

≤≤=

σ

σ

( )

( )26-1355MPa378125

25-135512MPa628.15.214

KLrr

ll

allow

≤=

<<⎥⎦⎢⎣ ⎠⎜⎝

−=

σ

σ

©2005 Pearson Education South Asia Pte Ltd 5

( )( )26-1355

/ 2 rrKLallow ≤=σ

Page 6: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING

Aluminum columns

©2005 Pearson Education South Asia Pte Ltd 6

Page 7: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING

Timber columns• Timber design formulae published by the National• Timber design formulae published by the National

Forest Products Association (NFPA) or American Institute of Timber Construction (AITC).( )

©2005 Pearson Education South Asia Pte Ltd 7

Page 8: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING

Timber columns• NFPA’s formulae for short, intermediate and longNFPA s formulae for short, intermediate and long

columns having a rectangular x-section of dimensions b and d (smallest dimension),

( )27-13110MPa25.8 ≤≤=d

KLallowσ

( )28-132611MPa026/

31125.8

2≤<

⎥⎥⎦

⎢⎢⎣

⎡⎟⎠⎞

⎜⎝⎛−=

dKLdKL

d

allowσ

( )( )29-135026MPa3718

0.263

2 ≤<=

⎥⎦⎢⎣ ⎠⎝

dKL

d

allowσ

©2005 Pearson Education South Asia Pte Ltd 8

( )( )

/ 2 ddKLallow

Page 9: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING

Procedure for analysisColumn analysisColumn analysis• When using any formula to analyze a column, or to

find its allowable load, it is necessary to calculate , ythe slenderness ratio in order to determine which column formula applies.

• Once the average allowable stress has been computed, the allowable load in the column is d t i d f P Adetermined from P = σallowA.

©2005 Pearson Education South Asia Pte Ltd 9

Page 10: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING

Procedure for analysisColumn designColumn design• If a formula is used to design a column, or to

determine the column’s x-sectional area for a given gloading and effective length, then a trial-and-check procedure generally must be followed if the column has a composite shape, such as a wide-flange section.O i t th l ’ ti l• One way is to assume the column’s x-sectional area, A’, and calculate the corresponding stress σ‘ = P/A’

©2005 Pearson Education South Asia Pte Ltd 10

σ = P/A .

Page 11: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING

Procedure for analysisColumn designColumn design• Also, with A’ use an appropriate design formula to

determine the allowable stress allow.• From this, calculate the required column area

Areq’d = P/σallow.req d allow

• If A’ > Areq’d, the design is safe. When making comparison, it is practical to require A’ to be close to but greater than Areq’d, usually within 2-3%. A redesign is necessary if A’ > Areq’d.

©2005 Pearson Education South Asia Pte Ltd 11

Page 12: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING

Procedure for analysisColumn designColumn design• Whenever a trial-and-check procedure is repeated,

the choice of an area is determined by the ypreviously calculated required area.

• In engineering practice, this method for design is g g p gusually shortened through the use of computer software or published tables and graphs.

©2005 Pearson Education South Asia Pte Ltd 12

Page 13: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.8An A-26 steel W250×149 member is used as a pin-supported column. Using AISC column gdesign formulae, determine the largest load that it can safely support. Est = 200(103) MPa, σY = 250 MPa.

©2005 Pearson Education South Asia Pte Ltd 13

Page 14: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.8 (SOLN)

From Appendix B,A = 19000 mm2; r = 117 mm; r = 67 4 mmA = 19000 mm ; rx = 117 mm; ry= 67.4 mm.Since K = 1 for both x and y axes buckling, slenderness ratio is largest if r is used Thusslenderness ratio is largest if ry is used. Thus

( )( )( )

18.74mm467

mm/m1000m51 ==r

KL

From Eqn 13-22, ( )mm4.67r

2 2=⎞

⎜⎛ π EKL

( )( )MPa102002 32

=⎠

⎜⎝

π

σYcr

©2005 Pearson Education South Asia Pte Ltd 14

( )( ) 66.125MPa250

MPa102002==

π

Page 15: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.8 (SOLN)Here 0 < KL/r < (KL/r)c, so Eqn 13-23 applies

( )1874 2 ⎤⎡ ( )( )( ) ( )1874187435

MPa25066.1252

18.741

3

2

⎤⎡⎤⎡⎞⎛

⎥⎦

⎤⎢⎣

⎡−

=allowσ( )( )

( )( )66.1258

18.7466.125818.743

35

3

3⎥⎦

⎤⎢⎣

⎡−⎥⎦

⎤⎢⎣⎡+⎟

⎠⎞

⎜⎝⎛

Allowable load P on column is

MPa85.110=

Allowable load P on column is

mm19000N/mm85.110; 2

2 == PA

Pallowσ

©2005 Pearson Education South Asia Pte Ltd 15

kN2106N2106150 ==P

Page 16: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns

©2005 Pearson Education South Asia Pte Ltd 16

Page 17: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns

©2005 Pearson Education South Asia Pte Ltd 17

Page 18: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.10A bar having a length of 750 mm is used to support an axial compressive load of 60 kN. It is pin-supported at its ends and made f 2014 T6 l i llfrom a 2014-T6 aluminum alloy.Determine the dimensions of its x-sectional area if its width is to bex-sectional area if its width is to be twice its thickness.

©2005 Pearson Education South Asia Pte Ltd 18

Page 19: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.10 (SOLN)

Since KL = 750 mm is the same for x-x and y-y axes buckling, largest slenderness ratio is determinedbuckling, largest slenderness ratio is determined using smallest radius of gyration, using Imin = Iy:

( ) 125987501KLKL ( )( ) ( ) ( )[ ]

( )11.25982/212/1

7501/ 3 bbbbbAI

KLrKL

yy===

Since we do not know the slenderness ratio, we apply Eqn 13-24 first,q ,

( )( )

N/mm1952

N1060;N/mm195 23

2 ==bbA

P

©2005 Pearson Education South Asia Pte Ltd 19

( )mm40.12=b

Page 20: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.10 (SOLN)

Checking slenderness ratio, 12598KL

Try Eqn 13 26 which is valid for KL/r ≥ 55;

125.20940.12

1.2598>==

rKL

Try Eqn 13-26, which is valid for KL/r ≥ 55;

MPa378125=

P( )

( ) 3781251060

/3

2rKLA

( )( ) ( )

mm0527/1.2598

3781252

10602

=

=

bbbb

©2005 Pearson Education South Asia Pte Ltd 20

mm05.27=b

Page 21: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.10 (SOLN)

From Eqn (1),

O !00961.2598KL

Note: It would be satisfactory to choose the x section

OK!5500.9605.27

1.2598>==

rKL

Note: It would be satisfactory to choose the x-section with dimensions 27 mm by 54 mm.

©2005 Pearson Education South Asia Pte Ltd 21

Page 22: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.11A board having x-sectional dimensions of 150 mm by 40 mm yis used to support an axial load of 20 kN. If the board is assumed to be pin-supported at its top and base, determine its greatest allo abledetermine its greatest allowable length L as specified by the NFPA.

©2005 Pearson Education South Asia Pte Ltd 22

Page 23: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.11 (SOLN)By inspection, board will buckle about the y axis. In the NFPA eqns, d = 40 mm. Assuming that Eqn 13-29 applies, we have

MP3718P( )

( )/MPa3718

2=dKLA

P

( )( )( ) ( )mm40/1

N/mm3718mm40mm150

N10202

23=

L( )mm1336=L

©2005 Pearson Education South Asia Pte Ltd 23

Page 24: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.11 (SOLN)

Here ( ) 4.33mm40

mm13361==

dKL

Since 26 < KL/d ≤ 50 the solution is valid

mm40d

Since 26 < KL/d ≤ 50, the solution is valid.

©2005 Pearson Education South Asia Pte Ltd 24

Page 25: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.7 DESIGN OF COLUMNS FOR ECCENTRIC LOADING

• A column may be required to support a load acting at its

d l b k tedge or on an angle bracket attached to its side.

• The bending moment M = Pe• The bending moment M = Pe, caused by eccentric loading, must be accounted for when column is designed.

Use of available column formulaeSt di t ib ti ti ti l f• Stress distribution acting over x-sectional area of column shown is determined from both axial force Pand bending moment M = Pe.

©2005 Pearson Education South Asia Pte Ltd 25

and bending moment M Pe.

Page 26: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.7 DESIGN OF COLUMNS FOR ECCENTRIC LOADING

Use of available column formulae• Maximum compressive stress isMaximum compressive stress is

( )30-13max IMc

AP+=σ

• A typical stress profile is also shown here. • If we assume entire x-section is subjected to uniform• If we assume entire x-section is subjected to uniform

stress σmax, then we can compare it with σallow, which is determined from formulae given in chapter 13.6.g p

• If σmax ≤ σallow, then column can carry the specified load.

©2005 Pearson Education South Asia Pte Ltd 26

Page 27: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.7 DESIGN OF COLUMNS FOR ECCENTRIC LOADING

Use of available column formulae• Otherwise, the column’s area A is increased and aOtherwise, the column s area A is increased and a

new σmax and σallow are calculated.• This method of design is rather simple to apply and g p pp y

works well for columns that are short or intermediate length.

• Calculations of σallow is usually done using the largest slenderness ratio for the column regardless

f th i b t th l i b diof the axis about the column experiences bending.

©2005 Pearson Education South Asia Pte Ltd 27

Page 28: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.7 DESIGN OF COLUMNS FOR ECCENTRIC LOADING

Interaction formula• It is sometimes desirable to see how the bendingIt is sometimes desirable to see how the bending

and axial loads interact when designing an eccentrically loaded column.

• We will consider the separate contributions made to the total column area from the axial force and the moment.

• If allowable stress for axial load is (σa)allow, then i d f th l d d t t threquired area for the column needed to support the

load P isPA =

©2005 Pearson Education South Asia Pte Ltd 28

( )allowaaA

σ=

Page 29: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.7 DESIGN OF COLUMNS FOR ECCENTRIC LOADING

Interaction formula• Similarly, if allowable bending stress is (σb)allow, thenSimilarly, if allowable bending stress is (σb)allow, then

since I = Ar2, required area of column needed to resist eccentric moment is determined from flexure formula,

( ) 2rMcAallowb

b σ=

©2005 Pearson Education South Asia Pte Ltd 29

Page 30: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.7 DESIGN OF COLUMNS FOR ECCENTRIC LOADING

Interaction formula• Thus, total area A for the column needed to resistThus, total area A for the column needed to resist

both axial force and bending moment requires that

( ) ( )2

2 ≤+=+allowballowa

ba Ar

McPAAσσ

( ) ( )

( )

1// 2

≤+allowballowa

ArMcAPor

σσσσ

( ) ( ) ( )31-131≤+allowb

b

allowa

a

σσ

σσ

©2005 Pearson Education South Asia Pte Ltd 30

Page 31: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.7 DESIGN OF COLUMNS FOR ECCENTRIC LOADING

Interaction formulaσa = axial stress caused by force P and determinedσa axial stress caused by force P and determined

from σa = P/A, where A is the x-sectional area of the column.

σb = bending stress caused by an eccentric load or applied moment M; σb is found from σb = Mc/I, where I is the moment of inertia of x-sectional area computed about the bending or neutral axis.

( ) ( ) 1

McPallowb

b

allowa

a ≤+σσ

σσ

©2005 Pearson Education South Asia Pte Ltd 31

( ) ( ) ( )31-132 Ar

McP

allowballowa

≤+σσ

Page 32: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.7 DESIGN OF COLUMNS FOR ECCENTRIC LOADING

Interaction formula(σa)allow = allowable axial stress as defined by formulae(σa)allow allowable axial stress as defined by formulae

given in chapter 13.6 or by design code specs. Use the largest slenderness ratio for the column, regardless of which axis it experiences bending.

(σb)allow = allowable bending stress as defined by code specifications.

( ) ( )12 ≤+ ba σσ

( ) ( )

( )31131

2

≤+McP

rallowballowa σσ

©2005 Pearson Education South Asia Pte Ltd 32

( ) ( )( )31-1312 ≤+

rallowballowa σσ

Page 33: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns*13.7 DESIGN OF COLUMNS FOR ECCENTRIC LOADING

Interaction formula• Eqn 13-31 is sometimes referred to as theEqn 13 31 is sometimes referred to as the

interaction formula.• This approach requires a trial-and-check procedure.pp q p• Designer needs to choose an available column and

check to see if the inequality is satisfied. q y• If not, a larger section is picked and the process

repeated. • American Institute of Steel Construction specifies

the use of Eqn 13-31 only when the axial-stress ratio

©2005 Pearson Education South Asia Pte Ltd 33

σa/(σa)allow ≤ 0.15.

Page 34: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.12Column is made of 2014-T6 aluminum alloy and is used to ysupport an eccentric load P. Determine the magnitude of P that

b t d if l i fi dcan be supported if column is fixed at its base and free at its top. Use Eqn 13-30Eqn 13-30.

©2005 Pearson Education South Asia Pte Ltd 34

Page 35: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.12 (SOLN)

K = 2. Largest slenderness ratio for column is( )mm16002KL ( )

( )( )( )[ ] ( )( )[ ]1.277

mm80mm40/mm408012/1mm160023mm

==r

KL

By inspection, Eqn 13-26 must be used (277.1 > 55).MP378125MP378125

( ) ( )MPa92.4

1.277MPa378125MPa378125

22allow ===rKL

σ

©2005 Pearson Education South Asia Pte Ltd 35

Page 36: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.12 (SOLN)

Actual maximum compressive stress in the column is determined from the combination of axial load anddetermined from the combination of axial load and bending. ( )

IcPe

AP

max +=σ

( )( )( )

( )( )( )PP

mm80mm4012/1mm40mm20

mm80mm40 3+=

Assuming that this stress is uniform over the x-

( ) ( )( )( )P00078125.0=

Assuming that this stress is uniform over the xsection, instead of just at the outer boundary,

00078125.092.4;maxallow == Pσσ

©2005 Pearson Education South Asia Pte Ltd 36

kN30.6N6.6297;maxallow

==P

Page 37: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.13The A-36 steel W150×30 column is pin-connected at its ends and subjected to eccentric load P. Determine the maximum

ll bl l f P i thallowable value of P using the interaction method if allowable bending stress isbending stress is (σb)allow = 160 MPa, E = 200 GPa, and σY = 250 MPa.Y

©2005 Pearson Education South Asia Pte Ltd 37

Page 38: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.13 (SOLN)

K = 1. The geometric properties for the W150×30 are taken from the table in Appendix B.taken from the table in Appendix B.

mm101.17mm3790 462 ×== IA x

We consider r as it lead to largest value of the

mm157mm2.38 == dry

We consider ry as it lead to largest value of the slenderness ratio. Ix is needed since bending occurs about the x axis (c = 157 mm/2 = 78.5 mm). To ( )determine the allowable bending compressive stress, we have ( )( ) 71104mm/m1000m41KL

©2005 Pearson Education South Asia Pte Ltd 38

( )( ) 71.104mm2.38

==r

Page 39: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of Columns

©2005 Pearson Education South Asia Pte Ltd 39

Page 40: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.13 (SOLN)

Then KL/r < (KL/r)c and so Eqn 13-23 must be used.( )71104 2 ⎤⎡ ( )( )( ) ( )

MPa25066.125271.1041

3

2

allow ⎤⎡⎤⎡⎞⎛

⋅⎥⎦

⎤⎢⎣

⎡−

=σ( )( )

( )( )

}66.125871.104

66.125871.1043

35{ 3

3allow

⎥⎦

⎤⎢⎣

⎡−⎥⎦

⎤⎢⎣⎡+⎟

⎠⎞

⎜⎝⎛

A i th t thi t i if th

MPa59.85=

Assuming that this stress is uniform over the x-section, instead of just at the outer boundary,

©2005 Pearson Education South Asia Pte Ltd 40

Page 41: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.13 (SOLN)

Applying the interaction formula Eqn 13-31 yieldsbσσ

( ) ( )( )( ) ( ) mm10117/2/mm157mm750mm3790/

1

462

≤+

PPallowb

b

allowa

a

σσ

σσ

( )( ) ( )

kN6540

1N/mm160

mm101.17/2/mm157mm750N/mm59.85

mm3790/22

=

=+

P

PP

Checking application of interaction method for steel section we require

kN65.40=P

section, we require

( ) ( ) OK!1501250mm3790/N1065.40 23<==aσ

©2005 Pearson Education South Asia Pte Ltd 41

( ) ( ) OK!15.0125.0N/mm59.85 2 <==

allowσ

Page 42: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.14Timber column is made from two boards nailed together so gthe x-section has the dimensions shown. If column is fixed at its base and free at its top, use Eqn 13-30 to determine the eccentric load Pdetermine the eccentric load Pthat can be supported.

©2005 Pearson Education South Asia Pte Ltd 42

Page 43: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.14 (SOLN)

K = 2. Here, we calculate KL/d to determine which eqn to use. Since σallow is determined using theeqn to use. Since σallow is determined using the largest slenderness ratio, we choose d = 60 mm.This is done to make the ratio as large as possible, g p ,and thus yield the lowest possible allowable axial stress.This is done even though bending due to P is about the x axis. ( )mm12002KL ( ) 40

mm60mm12002

==d

KL

©2005 Pearson Education South Asia Pte Ltd 43

Page 44: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsEXAMPLE 13.14 (SOLN)

Allowable axial stress is determined using Eqn 13-29 since 26 < KL/d < 50. Thussince 26 KL/d 50. Thus

( ) ( )MPa324.2

40MPa3718

/MPa3718

22 ===dKL

allowσ

Applying Eqn 13-30 with σallow = σmax, we have( ) ( )40/ dKL

( )( )6080

allow +=

PPI

McAPσ

( )( )( )

( )( )( )mm120mm60012/1mm60mm80

mm120mm60N/mm324.2 3

2 +=PP

©2005 Pearson Education South Asia Pte Ltd 44

kN35.3=P

Page 45: 13. Buckling of Columns *13.6 DESIGN OF COLUMNS FOR ...fac.ksu.edu.sa/sites/default/files/chap4.pdf · *13.6 DESIGN OF COLUMNS FOR CONCENTRIC LOADING ... • If a formula is used

13. Buckling of ColumnsCHAPTER REVIEW

• Buckling is the sudden instability that occurs in columns or members that support an axial load.

• The maximum axial load that a member can support just before buckling occurs is called the critical load Pcr.

• The critical load for an ideal column is determined from the Euler eqn, Pcr = π2EI/(KL)2, where K = 1 for pin supports, K = 0.5 for fixed supports, K = 0 7 for a pin and a fixed support and K = 2 forK = 0.7 for a pin and a fixed support, and K = 2 for a fixed support and a free end.

©2005 Pearson Education South Asia Pte Ltd 45