3
GENERAL ELECTRIC COMPANY GAS TURBINE Greenville, SC GE Energy - 0 [0] 0 [0] R E V D E S C R I P T I O N D A T E A P P R O V E D R E V I S I O N S SIZE UNLESS OTHERWISE SPECIFIED SCALE SHEET DWG NO CAGE CODE D I M E N S I O N S A R E I N I N C H E S TOLERANCES ON: 2 PL DECIMALS 3 PL DECIMALS ANGLES FRACTIONS D I S T R T O SIZE DWG NO SH REV SIZE DWG NO SH REV S I G N A T U R E S D A T E SIM TO: D R A W N CHECKED E N G R G ISSUED T H I R D A N G L E P R O J E C T I O N 0 [0] 0 [0] 0 [0] DIAGRAM,SCHEM PP-LIQ FUEL REVISE ON CAD ONLY NX PART: 104T4691 104T4691 104T4691 104T4691 FIRST MADE FOR 367A6724G002 0424 NONE 1 OF 3 1 1 A A SEE PLM SEE PLM FORMAT_WIZARD 3.0.1 C COPYRIGHT 2012 GE ENERGY (USA), LLC AND/OR ITS AFFILIATES. ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GE ENERGY GAS TURBINE PROPRIETARY TECHNICAL INFORMATION THAT BELONGS TO THE GENERAL ELECTRIC COMPANY, GE ENERGY (USA), LLC AND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FOR THE EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS, FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BE DEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREED TO MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVER FOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZED IN WRITING BY THE GENERAL ELECTRIC COMPANY, GE ENERGY (USA), LLC AND/OR ITS AFFILIATES. 123E5977 THIS DOCUMENT SHALL BE REVISED IN ITS ENTIRETY. ALL SHEETS OF THIS DOCUMENT ARE THE NSAME REVISION LEVEL AS INDICATED. GE CLASS II (INTERNAL NON-CRITICAL) - - - - NOTES: 1. SEE DEVICE SUMMARY MLI 0414 FOR DEVICE SETTINGS AND RATINGS. 2. THE REQUIREMENTS IN THE SYSTEM AND COMPONENT CLEANLINESS SPECIFICATION INCLUDED IN 362A2412 APPLY. 3. THE TERM "OTHERS" USED ON THIS DRAWING IS DEFINED AS THE PLANT DESIGNER AND/OR PLANT INSTALLER. 4. THIS PC MUST BE CONNECTED TO AN UN PRESSURIZED VESSEL AND MUST REMAIN OPEN. 5. VALVE IN THE CROSSOVER FILL LINE MUST BE OPEN TO EQUALIZE THE PRESSURE IN BOTH FILTERS PRIOR TO OPERATING THE FILTER TRANSFER VALVE. 6. REFER TO LIQUID FUEL LEAK TEST AND BLOWDOWN PROCEDURE INCLUDED IN 361A5550. 7. LIQUID FUEL SYSTEM RATED FOR LIGHT DISTILLATE SERVICE AS GIVEN IN LIQUID FUEL SPECIFICATION INCLUDED IN GEI-41047. 8. ISOLATION VALVE IN INTERCONNECT PIPING TO LF1 MUST BE SUPPLIED BY OTHERS. LOCATE VALVE IN OPEN AREA NEAR MODULE FOR FIRE FIGHTER USE. 9. FOR THIS MODULE SPILL DRAIN, TRAP AND ISOLATION VALVE TO AN UNPRESSURIZED VESSEL MUST BE SUPPLIED BY OTHERS. 10. A DRAIN LINE DEDICATED EXCLUSIVELY TO THIS INTERFACE CONNECTION IS REQUIRED. LIST OF COMPLEMENTARY DOCUMENTS IT. NOMENCLATURE IDENT EDUARDO NAJERA 12-06-15 ROHIT SHARMA SYM, PP 1 12-06-15 372A3671 INTERFACE POINT NAME SHEET &ZONE SH 2 E8 SH 2 D8 SH 3 D8 SH 3 D5 SH 2 E2 SH 3 G4 SH 3 D4 FLUID TYPE LIQUID FUEL LIQUID FUEL LIQUID FUEL LIQUID FUEL LIQUID FUEL LIQUID FUEL MINIMUM PRESSURE PSIG [KPAG] 52.5 [362] 0 [0] 52.5 [362] 52.5 [362] LIQUID FUEL LF1 LF9 LF69 LF82A TO LF82R LF80A TO LF80R LF81A TO LF81R LF79A TO LF79R MINIMUM TEMPERATURE F [ C] 30 [-1] 30 [-1] 30 [-1] 30 [-1] 30 [-1] 30 [-1] 30 [-1] MINIMUM FLOW USGPM [LPM] 65 [448] 150 [1030] 30 [207] 1200 [8270] 1200 [8270] 1200 [8270] 1200 [8270] 16 [61] 0.88 [3.33] 0.88 [3.33] MAXIMUM PRESSURE PSIG [KPAG] MAXIMUM TEMPERATURE F [ C] 120 [49] 120 [49] 120 [49] 120 [49] 120 [49] 120 [49] 120 [49] MAXIMUM FLOW USGPM [LPM] 390 [1480] 5 [19] 16 [60.6] 21.7 [82] 21.7 [82] 0.88 [3.33] 0.88 [3.33] DESIGN PRESSURE PSIG [KPAG] 200 [1380] 200 [1380] 150 [1030] 1200 [8270] 1200 [8270] 1200 [8270] 1200 [8270] DESIGN TEMPERATURE F [ C] 200 [93] 200 [93] 200 [93] 200 [93] 200 [93] 200 [93] 200 [93] DESIGN FLOW USGPM [LPM] 390 [1480] 5 [19] 27 [102] 21.7 [82] 21.7 [82] 1.5 [5.7] 1.5 [5.7] LIQUID FUEL SUPPLY TO NOZZLES LIQUID FUEL SUPPLY TO NOZZLES CONNECTION DESCRIPTION FUEL OIL INLET WASTE FUEL OIL DRAIN LIQUID FUEL RECIRCULATION TO FUEL MANAGEMENT SPOOL LIQUID FUEL RECIRCULATION LIQUID FUEL RECIRCULATION INTERFACE TYPE GEE-OTHERS GEE-OTHERS GEE-OTHERS GEE-GEE 0 [0] 11. DURING LIQUID FUEL OPERATION, PRESSURE OSCILLATIONS MUST NOT EXCEED 10 PSIG [68.9 KPAG] IN 10 SECONDS AT STARTUP AND 8 PSIG [55.2 KPAG] PER MINUTE AFTER IGNITION. 12. 3 WAY PURGE VALVE LOCATED IN PURGE SYSTEM MLI 0477 IS SHOWN IN THE NORMAL (UN-ACTUATED) POSITION. HOWEVER, VALUES SHOWN IN LINE LFC-1 THROUGH 18 REPRESENT CONDITIONS DURING LIQUID FUEL OPERATION WHERE THE VALVE IS IN THE ACTUATED POSITION. 13. INSTRUMENT AIR TO BE SUPPLIED BY OTHERS, MUST BE IN ACCORDANCE WITH GEK 110727. AIR SUPPLY REQUIRED TO BE SUPPLIED PRIOR TO STARTUP OF TURBINE. DESIGN FLOW IS 0.04 PPS [0.02 KGS] 10 SECONDS TRANSIENT AND 0.01 PPS [0.006 KGS] STEADY STATE. MINIMUM PRESSURE IS 90 PSIG [620 KPAG]. 14. UPSTREAM OF VALVE VA70-5 THE DESIGN PRESSURE IS 1200 PSIG [8270 KPAG] DOWNSTREAM OF VALVE VA70-5 THE DESIGN PRESSURE IS 200 PSIG [1380 KPAG]. 15. PRESSURE DROP IN INTERCONNECT PIPE BETWEEN LF69 AND FMS5 MUST NOT EXCEED 2.5 PSIG [17.2 KPAG] AT THE DESIGN FLOW RATE. THE PRESSURE DROP FROM LF69 TO THE FUEL OIL TANK MUST NOT EXCEED 25 PSIG [172 KPAG]. ATMOSPHERIC TANK AND BOOSTER PUMP MUST BE INSTALLED BY OTHERS TO MEET PRESSURE DROP REQUIREMENTS. 16. ALL CROSSHATCHED AREAS TO BE DISABLED/REMOVED. INTERFACE POINT NAME H07 LF17 LF63 LINE LFC-1 TO 18 LF76 LF77 LF78 LINE LFD-2- 1 TO 2-18 LINE OLT-3 LINE OL-20 SHEET &ZONE SH 2 B4 SH 3 B4 SH 2 B6 SH 3 C3 SH 3 G4 SH 3 D2 SH 3 H4 SH 3 C4 SH 2 C4 SH 2 C5 FLUID TYPE OIL LIQUID FUEL/ AIR/WATER LIQUID FUEL/ OIL/COOLANT LIQUID FUEL/ AIR AIR/WATER/ LIQUID FUEL AIR/WATER/ LIQUID FUEL LIQUID FUEL/ AIR OIL/AIR OIL OIL NORMAL PRESSURE PSIG [KPAG] 1630 [11200] 600 [4140] 100 [690] NORMAL TEMPERATURE F [ C] 130 [54] 30 TO 120 [-1 TO 49] 30 TO 120 [-1 TO 49] 30 TO 120 [-1 TO 49] 30 TO 120 [-1 TO 49] 30 TO 120 [-1 TO 49] 30 TO 120 [-1 TO 49] 30 TO 120 [-1 TO 49] 130 [54] 130 [54] NORMAL FLOW USGPM [LPM] 1.0 [3.8] 1.0 [3.8] 19 [72] DESIGN PRESSURE PSIG [KPAG] 1840 [12700] 150 [1030] 150 [1030] 150 [1030] 150 [1030] 150 [1030] 150 [1030] 1200 [8270] 200 [1380] 2 [13.8] DESIGN TEMPERATURE F [ C] 175 [79] 175 [79] 175 [79] 200 [93] OIL 250 [121] AIR 200 [93] OIL 250 [121] AIR 200 [93] 200 [93] 200 [93] 200 [93] 200 [93] DESIGN FLOW USGPM [LPM] 3.0 [11.4] 3 [11.4] 0.5 [1.89] 0.5 [1.89] 0.5 [1.89] 27 [102] 21.7 [82] 1 [3.8] 1 [3.8] 2.0 [7.6] LIQUID FUEL RECIRCULATION VENT PRESSURE CONNECTION DESCRIPTION HYDRAULIC OIL SUPPLY FUEL DISTRIBUTION VALVE LEAKOFF DRAIN LIQUID FUEL/ATOMIZING AIR MODULE (A162) BASE FLOOR DRAIN LIQUID FUEL SUPPLY TO NOZZLES (SEE NOTE 14) AIR VENT FROM LIQUID FUEL RECIRCULATION AIR VENT FROM LIQUID FUEL RECIRCULATION LIQUID FUEL DRAIN TRIP OIL TO LIQUID FUEL VALVES LF HYDRAULIC OIL RETURN INTERFACE TYPE GEE-OTHERS GEE-GEE GEE-OTHERS GEE-GEE GEE-GEE GEE-GEE GEE-GEE GEE-GEE GEE-GEE GEE-GEE INTERFACE POINT NAME LF70 LF71 LINE IA-4 SHEET &ZONE FLUID TYPE NORMAL PRESSURE PSIG [KPAG] NORMAL TEMPERATURE F [ C] SH 3 G4 SH 3 G4 SH 2 G3 AIR AIR AIR 105 [724] 105 [724] 105 [724] 30 TO 120 [-1 TO 49] 30 TO 120 [-1 TO 49] 30 TO 120 [-1 TO 49] NORMAL FLOW PPS [KG/S] DESIGN PRESSURE PSIG [KPAG] DESIGN TEMPERATURE F [ C] DESIGN FLOW PPS [KG/S] 120 [827] 120 [827] 120 [827] 150 [66] 150 [66] 150 [66] 0.04 [0.02] 0.04 [0.02] 0.04 [0.02] INSTRUMENT AIR FROM LF/AA PURGE INSTRUMENT AIR TO VA70-6 INSTRUMENT AIR TO VA70-5 CONNECTION DESCRIPTION INTERFACE TYPE GEE-OTHERS GEE-OTHERS GEE-GEE 0 [0] 0 [0] 0 [0] GEE-GEE GEE-GEE GEE-GEE 0 [0] 0 [0] 0 [0] 0 [0] 0 [0] 0 [0] 0 [0] 0 [0] 0 [0] 0 [0] 0 [0] 0 [0] 0 [0] 0 [0] 0 [0] A REVISED THIS SHEET 1) CHANGED NOTE 13 DINA MUSE 2012-09-14 SEE PLM A1 DWG Number 104T4691 Rev A Released 10/15/2012 GE Proprietary Information - Class II (Internal) US EAR - NLR

104T4691_A Liquid Fuel

  • Upload
    seshats

  • View
    40

  • Download
    11

Embed Size (px)

DESCRIPTION

ge 9fa liquid fule

Citation preview

Page 1: 104T4691_A Liquid Fuel

GENERAL ELECTRIC COMPANYGAS TURBINE

Greenville, SCGE Energy

-

0 [0]

0 [0]

R E V D E S C R I P T I O N D A T E A P P R O V E D

R E V I S I O N S

SIZE

UNLESS OTHERWISE SPECIFIED

SCALE SHEET

DWG NOCAGE CODE

D I M E N S I O N S A R E I N I N C H E S

TOLERANCES ON:2 PL DECIMALS 3 PL DECIMALS ANGLES FRACTIONS

DI

ST

R

TO

SIZE DWG NO SH REV

SIZ

ED

WG

NO

SH

RE

V

S I G N A T U R E S D A T E

SIM TO:

D R A W N

CHECKED

E N G R G

ISSUED

T H I R D A N G L E P R O J E C T I O N

0 [0]

0 [0]

0 [0]

DIAGRAM,SCHEM PP-LIQ FUEL

REVISE ON CAD ONLYNX PART: 104T4691

104T4691

104T

4691

104T4691

FIRST MADE FOR 367A6724G002 0424

NONE 1 OF 3

1

1

A

A

SEE PLM

SEE PLM

FORMAT_WIZARD 3.0.1

C COPYRIGHT 2012 GE ENERGY (USA), LLC AND/OR ITS AFFILIATES.

ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GEENERGY GAS TURBINE PROPRIETARY TECHNICAL INFORMATION THATBELONGS TO THE GENERAL ELECTRIC COMPANY, GE ENERGY (USA), LLCAND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FORTHE EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS,FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BEDEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREEDTO MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVERFOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZEDIN WRITING BY THE GENERAL ELECTRIC COMPANY, GE ENERGY (USA), LLCAND/OR ITS AFFILIATES. 123E5977

THIS DOCUMENT SHALL BE REVISEDIN ITS ENTIRETY. ALL SHEETS OFTHIS DOCUMENT ARE THE NSAMEREVISION LEVEL AS INDICATED.

GE CLASS II (INTERNAL NON-CRITICAL)

--- -

NOTES:

1. SEE DEVICE SUMMARY MLI 0414 FOR DEVICE SETTINGS AND RATINGS.

2. THE REQUIREMENTS IN THE SYSTEM AND COMPONENT CLEANLINESS SPECIFICATION INCLUDED IN 362A2412 APPLY.

3. THE TERM "OTHERS" USED ON THIS DRAWING IS DEFINED AS THE PLANT DESIGNER AND/OR PLANT INSTALLER.

4. THIS PC MUST BE CONNECTED TO AN UN PRESSURIZED VESSEL AND MUST REMAIN OPEN.

5. VALVE IN THE CROSSOVER FILL LINE MUST BE OPEN TO EQUALIZE THE PRESSURE IN BOTH FILTERS PRIOR TO OPERATING THE FILTER TRANSFER VALVE.

6. REFER TO LIQUID FUEL LEAK TEST AND BLOWDOWN PROCEDURE INCLUDED IN 361A5550.

7. LIQUID FUEL SYSTEM RATED FOR LIGHT DISTILLATE SERVICE AS GIVEN IN LIQUID FUEL SPECIFICATION INCLUDED IN GEI-41047.

8. ISOLATION VALVE IN INTERCONNECT PIPING TO LF1 MUST BE SUPPLIED BY OTHERS. LOCATE VALVE IN OPEN AREA NEAR MODULE FOR FIRE FIGHTER USE.

9. FOR THIS MODULE SPILL DRAIN, TRAP AND ISOLATION VALVE TO AN UNPRESSURIZED VESSEL MUST BE SUPPLIED BY OTHERS.

10. A DRAIN LINE DEDICATED EXCLUSIVELY TO THIS INTERFACE CONNECTION IS REQUIRED.

LIST OF COMPLEMENTARY DOCUMENTSIT. NOMENCLATURE IDENT

EDUARDO NAJERA 12-06-15

ROHIT SHARMA

SYM, PP1

12-06-15

372A3671

INTERFACEPOINTNAME

SHEET&ZONE

SH 2 E8

SH 2 D8

SH 3 D8

SH 3 D5

SH 2 E2

SH 3 G4

SH 3 D4

FLUIDTYPE

LIQUIDFUEL

LIQUIDFUEL

LIQUIDFUEL

LIQUIDFUEL

LIQUIDFUEL

LIQUIDFUEL

MINIMUMPRESSURE

PSIG [KPAG]

52.5 [362]

0 [0]

52.5 [362]

52.5 [362]

LIQUIDFUEL

LF1

LF9

LF69

LF82A TOLF82R

LF80A TOLF80R

LF81A TOLF81R

LF79A TOLF79R

MINIMUMTEMPERATURE

F [ C]

30 [-1]

30 [-1]

30 [-1]

30 [-1]

30 [-1]

30 [-1]

30 [-1]

MINIMUMFLOW

USGPM [LPM]

65 [448]

150 [1030]

30 [207]

1200 [8270]

1200 [8270]

1200 [8270]

1200 [8270]

16 [61]

0.88 [3.33]

0.88 [3.33]

MAXIMUMPRESSURE

PSIG [KPAG]

MAXIMUMTEMPERATURE

F [ C]

120 [49]

120 [49]

120 [49]

120 [49]

120 [49]

120 [49]

120 [49]

MAXIMUMFLOW

USGPM [LPM]

390 [1480]

5 [19]

16 [60.6]

21.7 [82]

21.7 [82]

0.88 [3.33]

0.88 [3.33]

DESIGNPRESSURE

PSIG [KPAG]

200 [1380]

200 [1380]

150 [1030]

1200 [8270]

1200 [8270]

1200 [8270]

1200 [8270]

DESIGNTEMPERATURE

F [ C]

200 [93]

200 [93]

200 [93]

200 [93]

200 [93]

200 [93]

200 [93]

DESIGNFLOW

USGPM [LPM]

390 [1480]

5 [19]

27 [102]

21.7 [82]

21.7 [82]

1.5 [5.7]

1.5 [5.7]

LIQUID FUEL SUPPLY TO NOZZLES

LIQUID FUEL SUPPLY TO NOZZLES

CONNECTION DESCRIPTION

FUEL OIL INLET

WASTE FUEL OIL DRAIN

LIQUID FUEL RECIRCULATIONTO FUEL MANAGEMENT SPOOL

LIQUID FUEL RECIRCULATION

LIQUID FUEL RECIRCULATION

INTERFACE TYPE

GEE-OTHERS

GEE-OTHERS

GEE-OTHERS

GEE-GEE

0 [0]

11. DURING LIQUID FUEL OPERATION, PRESSURE OSCILLATIONS MUST NOT EXCEED 10 PSIG [68.9 KPAG] IN 10 SECONDS AT STARTUP AND 8 PSIG [55.2 KPAG] PER MINUTE AFTER IGNITION.

12. 3 WAY PURGE VALVE LOCATED IN PURGE SYSTEM MLI 0477 IS SHOWN IN THE NORMAL (UN-ACTUATED) POSITION. HOWEVER, VALUES SHOWN IN LINE LFC-1 THROUGH 18 REPRESENT CONDITIONS DURING LIQUID FUEL OPERATION WHERE THE VALVE IS IN THE ACTUATED POSITION.

13. INSTRUMENT AIR TO BE SUPPLIED BY OTHERS, MUST BE IN ACCORDANCE WITH GEK 110727. AIR SUPPLY REQUIRED TO BE SUPPLIED PRIOR TO STARTUP OF TURBINE. DESIGN FLOW IS 0.04 PPS [0.02 KGS] 10 SECONDS TRANSIENT AND 0.01 PPS [0.006 KGS] STEADY STATE. MINIMUM PRESSURE IS 90 PSIG [620 KPAG].

14. UPSTREAM OF VALVE VA70-5 THE DESIGN PRESSURE IS 1200 PSIG [8270 KPAG] DOWNSTREAM OF VALVE VA70-5 THE DESIGN PRESSURE IS 200 PSIG [1380 KPAG].

15. PRESSURE DROP IN INTERCONNECT PIPE BETWEEN LF69 AND FMS5 MUST NOT EXCEED 2.5 PSIG [17.2 KPAG] AT THE DESIGN FLOW RATE. THE PRESSURE DROP FROM LF69 TO THE FUEL OIL TANK MUST NOT EXCEED 25 PSIG [172 KPAG]. ATMOSPHERIC TANK AND BOOSTER PUMP MUST BE INSTALLED BY OTHERS TO MEET PRESSURE DROP REQUIREMENTS.

16. ALL CROSSHATCHED AREAS TO BE DISABLED/REMOVED.

INTERFACEPOINTNAME

H07

LF17

LF63

LINE LFC-1TO 18

LF76

LF77

LF78

LINE LFD-2-1 TO 2-18

LINE OLT-3

LINE OL-20

SHEET&ZONE

SH 2 B4

SH 3 B4

SH 2 B6

SH 3 C3

SH 3 G4

SH 3 D2

SH 3 H4

SH 3 C4

SH 2 C4

SH 2 C5

FLUIDTYPE

OIL

LIQUID FUEL/AIR/WATER

LIQUID FUEL/OIL/COOLANT

LIQUID FUEL/AIR

AIR/WATER/LIQUID FUEL

AIR/WATER/LIQUID FUEL

LIQUID FUEL/AIR

OIL/AIR

OIL

OIL

NORMALPRESSURE

PSIG [KPAG]

1630 [11200]

600 [4140]

100 [690]

NORMALTEMPERATURE

F [ C]

130 [54]

30 TO 120[-1 TO 49]

30 TO 120[-1 TO 49]

30 TO 120[-1 TO 49]

30 TO 120[-1 TO 49]

30 TO 120[-1 TO 49]

30 TO 120[-1 TO 49]

30 TO 120[-1 TO 49]

130 [54]

130 [54]

NORMALFLOW

USGPM [LPM]

1.0 [3.8]

1.0 [3.8]

19 [72]

DESIGNPRESSURE

PSIG [KPAG]

1840 [12700]

150 [1030]

150 [1030]

150 [1030]

150 [1030]

150 [1030]

150 [1030]

1200 [8270]

200 [1380]

2 [13.8]

DESIGNTEMPERATURE

F [ C]

175 [79]

175 [79]

175 [79]

200 [93] OIL250 [121] AIR

200 [93] OIL250 [121] AIR

200 [93]

200 [93]

200 [93]

200 [93]

200 [93]

DESIGNFLOW

USGPM [LPM]

3.0 [11.4]

3 [11.4]

0.5 [1.89]

0.5 [1.89]

0.5 [1.89]

27 [102]

21.7 [82]

1 [3.8]

1 [3.8]

2.0 [7.6]

LIQUID FUEL RECIRCULATION VENT PRESSURE

CONNECTION DESCRIPTION

HYDRAULIC OIL SUPPLY

FUEL DISTRIBUTION VALVE LEAKOFF DRAIN

LIQUID FUEL/ATOMIZING AIR MODULE (A162)BASE FLOOR DRAIN

LIQUID FUEL SUPPLY TO NOZZLES(SEE NOTE 14)

AIR VENT FROM LIQUID FUEL RECIRCULATION

AIR VENT FROM LIQUID FUEL RECIRCULATION

LIQUID FUEL DRAIN

TRIP OIL TO LIQUID FUEL VALVES

LF HYDRAULIC OIL RETURN

INTERFACE TYPE

GEE-OTHERS

GEE-GEE

GEE-OTHERS

GEE-GEE

GEE-GEE

GEE-GEE

GEE-GEE

GEE-GEE

GEE-GEE

GEE-GEE

INTERFACEPOINTNAME

LF70

LF71

LINE IA-4

SHEET&ZONE

FLUIDTYPE

NORMALPRESSURE

PSIG [KPAG]

NORMALTEMPERATURE

F [ C]

SH 3 G4

SH 3 G4

SH 2 G3

AIR

AIR

AIR

105 [724]

105 [724]

105 [724]

30 TO 120[-1 TO 49]

30 TO 120[-1 TO 49]30 TO 120[-1 TO 49]

NORMALFLOW

PPS [KG/S]

DESIGNPRESSURE

PSIG [KPAG]

DESIGNTEMPERATURE

F [ C]

DESIGNFLOW

PPS [KG/S]

120 [827]

120 [827]

120 [827]

150 [66]

150 [66]

150 [66]

0.04 [0.02]

0.04 [0.02]

0.04 [0.02] INSTRUMENT AIR FROM LF/AA PURGE

INSTRUMENT AIR TO VA70-6

INSTRUMENT AIR TO VA70-5

CONNECTION DESCRIPTION INTERFACE TYPE

GEE-OTHERS

GEE-OTHERS

GEE-GEE

0 [0]

0 [0]

0 [0]

GEE-GEE

GEE-GEE

GEE-GEE

0 [0]

0 [0]

0 [0]

0 [0]

0 [0]

0 [0]

0 [0]

0 [0]

0 [0]

0 [0]

0 [0]

0 [0]

0 [0]

0 [0]

0 [0]

A

REVISED THIS SHEET

1) CHANGED NOTE 13

DINA MUSE

2012-09-14 SEEPLM

A1

DWG Number 104T4691 Rev A Released 10/15/2012

GE Proprietary Information - Class II (Internal) US EAR - NLR

Page 2: 104T4691_A Liquid Fuel

GE Energy

GENERAL ELECTRIC COMPANYGAS TURBINES

Greenville, SC

R E V D E S C R I P T I O N D A T E A P P R O V E D

R E V I S I O N S

DI

ST

R

TO

SIZE DWG NO SH REV

SIZ

ED

WG

NO

SH

RE

V

SIZE

D R A W N

ISSUED SCALE SHEET

DWG NOCAGE CODE

104T4691

104T

4691

104T4691

NONE 2 OF 3

2

2

A

A

SEE PLM

FORMAT_WIZARD 3.0.1

C COPYRIGHT 2012 GE ENERGY (USA), LLC AND/OR ITS AFFILIATES.

ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GEENERGY GAS TURBINE PROPRIETARY TECHNICAL INFORMATION THATBELONGS TO THE GENERAL ELECTRIC COMPANY, GE ENERGY (USA), LLCAND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FORTHE EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS,FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BEDEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREEDTO MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVERFOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZEDIN WRITING BY THE GENERAL ELECTRIC COMPANY, GE ENERGY (USA), LLCAND/OR ITS AFFILIATES.

EDUARDO NAJERA 12-06-15

OUT

PS

NO

ET-88FP1-1A/RET-88FP1-1B/RET-88FP1-2A/RET-88FP1-2B/RET-88FP1-3A/RET-88FP1-3B/RET-88FP1-4A/RET-88FP1-4B/R

DL-27 DL-49 AL-84A AL-85A ASW-42AAL-84B AL-85B ASW-42BAL-84C AL-85C

FRO

M M

LI

4038

FU

EL

MA

NA

GE

ME

NT

SP

OO

L P

IEC

E,

"FM

S3

"

TO LIQUID FUELWASTE DRAIN

SEENOTE 5

NC2

D

IN

IN

OUT

OUT

BP

P

OUT

1

R

IN

IN

BP

NCNC

HIGHPOINTVENT

NC

NCNC

NC

HIGHPOINTVENT

FILTERDRAIN

PDS63LF-5

PDILF-5

NO

PS63FL-2

NO

NO

0-25 PSID[0-172 KPAD]

PIFL-2

0-200 PSIG(0-1380 KPAG)

M

FUEL PUMPSEAL

LEAKOFF

FH3-1

VM5-1

FF1-1VR41-1

FF1-2VR41-2

PF1-1

HI PINDICATOR

VC3-1

LF1

LF9

SEE NOTE 8 & 11

SEE NOTE 4 & 10

VR4-1

VH4-1

OUT

PS

65FP-1

OUT

PS

FH4-1

HI PINDICATOR

VS1-1

TO A

ND

FRO

M M

LI

0418

TR

IP O

IL S

YS

TE

M, "T

O12"

OLT

-3

TO SHEET 3ZONE D-6, "LINE LFO-1"

LFO-1

LFO-2

LFO-3

LFO-4

LFO-5

LFO-6

LFO-7

LFO-8

LFO-9

LFO-10

LFO-11

LFO-12

LFO-13

LFO-14

FD1-1

77FD-177FD-277FD-3

NO

0 TO 1500 PSIG[0 TO 10300 KPAG]

S

VA70-1PT

96LFSP-1CNO

PT96LFSP-1B

NO

PT96LFSP-1A

NO

SG

20LFSP-1

VCK6-1

VH17-1NO

88FP-123FP-1

NONO NC

BYPASS

TO SHEET 3ZONE D-6, "LINE LFO-2"

TO SHEET 3ZONE D-6, "LINE LFO-3"

TO SHEET 3ZONE C-6, "LINE LFO-4"

TO SHEET 3ZONE C-6, "LINE LFO-5"

TO SHEET 3ZONE C-6, "LINE LFO-6"

TO SHEET 3ZONE C-6, "LINE LFO-7"

TO SHEET 3ZONE C-6, "LINE LFO-8"

TO SHEET 3ZONE C-6, "LINE LFO-9"

TO SHEET 3ZONE C-6, "LINE LFO-10"

TO SHEET 3ZONE B-6, "LINE LFO-11"

TO SHEET 3ZONE B-6, "LINE LFO-12"

TO SHEET 3ZONE B-6, "LINE LFO-13"

TO SHEET 3ZONE B-6, "LINE LFO-14"

TO C

US

TOM

ER

DR

AIN

TA

NK

LF63

SEE NOTE 9

REVISE ON CAD ONLYNX PART: 104T4691

0511

VCK6-7

ET-88FP1-5A/RET-88FP1-5B/R

0510

PT96LFSP-2A

PT96LFSP-2B

PT96LFSP-2C

IA-4

0.7 [18 MM]ORIFICE

VCK6-2

VALVEPACKINGLEAKOFF

0516

VCK6-3

TO M

LI

0416

LUB

E O

IL,

"LIN

E O

L-2

0"

OL-20

20FL-1

ZS33FL-1

PIFL-3

0.126[3,2 MM]ORIFICE

1082

NC

HIGHPOINTVENT

FROM MLI 0477, LF/AAPURGE, "LINE IA-4"

SG

FRO

M M

LI

04

34

HYD

RAU

LIC O

IL S

UP

PLY

, "H

O1

"

HO7

TO SHEET 3ZONE B-6, "LINE LFO-15"

LFO-15

TO SHEET 3ZONE B-6, "LINE LFO-16"

LFO-16

TO SHEET 3ZONE B-6, "LINE LFO-17"

LFO-17

TO SHEET 3ZONE B-6, "LINE LFO-18"

LFO-18

0613

LF81A TO LF81R

LIQUID FUEL/ATOMIZING (LF/AA MODULE A162

HIGHPOINTVENT

NC

PIFL-4

0 TO 1500 PSIG[0 TO 10300 KPAG]

TYPICAL18 PLACES

SEE NOTE 16

REVISION LEVEL UPDATEDONLY NO CHANGEA

DINA MUSE

2012-09-14 SEEPLM

GE CLASS II (INTERNAL NON-CRITICAL)

DWG Number 104T4691 Rev A Released 10/15/2012

GE Proprietary Information - Class II (Internal) US EAR - NLR

Page 3: 104T4691_A Liquid Fuel

GE Energy

GENERAL ELECTRIC COMPANYGAS TURBINES

Greenville, SC

R E V I S I O N S

DI

ST

R

TO

SIZE DWG NO SH REV

SIZ

ED

WG

NO

SH

RE

V

SIZE

D R A W N

ISSUED SCALE SHEET

DWG NOCAGE CODE

NONE 3 OF 3

3

3

A

A

SEE PLM

FORMAT_WIZARD 3.0.1

C COPYRIGHT 2012 GE ENERGY (USA), LLC AND/OR ITS AFFILIATES.

ALL RIGHTS RESERVED. THE INFORMATION CONTAINED HEREIN IS GEENERGY GAS TURBINE PROPRIETARY TECHNICAL INFORMATION THATBELONGS TO THE GENERAL ELECTRIC COMPANY, GE ENERGY (USA), LLCAND/OR THEIR AFFILIATES, WHICH HAS BEEN PROVIDED SOLELY FORTHE EXPRESS REASON OF RESTRICTED PRIVATE USE. ALL PERSONS,FIRMS, OR CORPORATIONS WHO RECEIVE SUCH INFORMATION SHALL BEDEEMED BY THE ACT OF THEIR RECEIVING THE SAME TO HAVE AGREEDTO MAKE NO DUPLICATION, OR OTHER DISCLOSURE, OR USE WHATSOEVERFOR ANY, OR ALL SUCH INFORMATION EXCEPT AS EXPRESSLY AUTHORIZEDIN WRITING BY THE GENERAL ELECTRIC COMPANY, GE ENERGY (USA), LLCAND/OR ITS AFFILIATES.

GE CLASS II (INTERNAL NON-CRITICAL)

EDUARDO NAJERA 12-06-15

96LF-10

104T

4691

104T4691

REVISE ON CAD ONLYNX PART: 104T4691

104T4691

FROM SHEET 2ZONE D-1, "LINE LFO-10"

FROM SHEET 2ZONE E-1, "LINE LFO-1"

FROM SHEET 2ZONE D-1, "LINE LFO-2"

FROM SHEET 2ZONE D-1, "LINE LFO-3"

FROM SHEET 2ZONE D-1, "LINE LFO-4"

FROM SHEET 2ZONE D-1, "LINE LFO-5"

FROM SHEET 2ZONE D-1, "LINE LFO-6"

FROM SHEET 2ZONE D-1, "LINE LFO-7"

FROM SHEET 2ZONE D-1, "LINE LFO-8"

FROM SHEET 2ZONE D-1, "LINE LFO-9"

FROM SHEET 2ZONE C-1, "LINE LFO-11"

FROM SHEET 2ZONE C-1, "LINE LFO-12"

FROM SHEET 2ZONE C-1, "LINE LFO-13"

FROM SHEET 2ZONE C-1, "LINE LFO-14"

FROM SHEET 2ZONE C-1, "LINE LFO-15"

FROM SHEET 2ZONE C-1, "LINE LFO-16"

FROM SHEET 2ZONE C-1, "LINE LFO-17"

FROM SHEET 2ZONE C-1, "LINE LFO-18"

LF82A TO LF82R

0961

D A T E

LFO-1

LFO-2

LFO-3

LFO-4

LFO-5

LFO-6

LFO-7

LFO-8

LFO-9

LFO-10

LFO-11

LFO-12

LFO-13

LFO-14

LFO-15

LFO-16

LFO-17

LFO-18

0961

ACTUATION AIR

PURGE AIR

D E S C R I P T I O N A P P R O V E D

0477

LF

D-2

-1 T

O 2

-1B

LFC-1 TO 18SEE NOTE 12

DISTRIBUTOR VALVE

TYPICAL FOR18COMBUSTORS

FUEL NOZZLE 0512

TYPICAL FOR18COMBUSTORS

R E V

SG

LF17

LIQUID FUEL RECIRCULATION MODULE 969S

LFRO-1

LF79A TO LF79R

9018

VCK6-4

9018

LF77

9018

0961

9018

LFD-1

TURBINE ENCLOSURE 1634

1 THRU 18 LFRI-1THRU LFRI-18

LF80ATO LF80R

INSTRUMENTAIR(BY OTHERS)SEE NOTE13

LF70

LF76

INSTRUMENTAIR(BY OTHERS)SEE NOTE13

LF71

0 TO 300 PSIG[0 TO 2070 KPAG]

PILFR-1

9018LF78

LFD-1

SEE NOTE 15

TILFR-1

0 TO 250 F[-18 TO 121 C]

FT-LR-1C FT-LR-1B FT-LR-1AVA70-5

NC

SEE NOTE 14

ZS33LF-5

S

LF69

NC

20LFSP-5

SG 0.10 [2,54 MM]

ORIFICENC

VA70-6

ZS33LF-6

VTA

S

NC

VTA

20LFSP-6

VENTSTANDPIPE

TO MLI 4038, FUEL MGMTSPOOL PIECE, "FMS5"

71LF-271LF-1

VTA

96LF-9

SEEPLMA REVISION LEVEL UPDATED

ONLY NO CHANGE 2012-09-14

DWG Number 104T4691 Rev A Released 10/15/2012

GE Proprietary Information - Class II (Internal) US EAR - NLR