Genevac Technology is protected by patents and patent applications in the UK and worldwide. Genevac Ltd has a continuous development programme aimed at further improving their products and all specifications are, therefore, subject to change. Coolheat®, VacRampTM (Dri-Pure®), SampleGuardTM and associated logos are trade marks of
Genevac Ltd, unauthorised use is prohibited.
GGeenneevvaacc EEvvaappoorraattoorrss
OOppttiioonnss && AAcccceessssoorriieess BBrroocchhuurree
1100--11447788 IIssssuuee 44--99 JJaannuuaarryy 22000099
AAddddiittiioonnaall SSaammppllee HHoollddeerrss aarree aavvaaiillaabbllee,, yyoouurr SSaalleess RReepprreesseennttaattiivveess ccaann aaddvviissee oonn aallll aaddddiittiioonnaall iitteemmss,, iinncclluuddiinngg ssppeecciiaall oorrddeerr iitteemmss..
CCoonntteennttss Introduction..................................................................................................................3
NNeeww RRaannggee......................................................................................................................................................................................................................................................................................................33 DDeeffiinniittiioonnss ........................................................................................................................................................................................................................................................................................................33 Geometry.....................................................................................................................................................3 FFaaccttoorrss aaffffeeccttiinngg eevvaappoorraattiioonn ppeerrffoorrmmaannccee ....................................................................................................................................................................................44 Heat transfer ...............................................................................................................................................4 PPrrootteeccttiivvee ccooaattiinnggss ..........................................................................................................................................................................................................................................................................44 Sample holders ............................................................................................................................................4 HCl or Thionyl Chloride ..........................................................................................................................4 MMaaxxiimmuumm CCaappaacciittyy ..........................................................................................................................................................................................................................................................................44 MMiinniimmiissiinngg TTuubbee BBrreeaakkaaggee ................................................................................................................................................................................................................................................55 MMaaiinntteennaannccee ..................................................................................................................................................................................................................................................................................................55 CCuussttoomm DDeessiiggnn ffoorr SSppeecciiaall AApppplliiccaattiioonn ..................................................................................................................................................................................................66 RRoottoorrss ......................................................................................................................................................................................................................................................................................................................66
HT Series & EZ-2 Evaporators ...................................................................................7 FFaasstt--SSttaacckk BBuucckkeett OOppttiioonnss ..............................................................................................................................................................................................................................................88 FFllaasskk HHoollddeerr OOppttiioonnss --SSwwiinngg ......................................................................................................................................................................................................................................99 FFllaasskk HHoollddeerr OOppttiioonnss --SSwwiinngg ................................................................................................................................................................................................................................ 1100 BBoottttllee//BBeeaakkeerr HHoollddeerr OOppttiioonnss --SSwwiinngg ................................................................................................................................................................................................ 1111 TTuubbee HHoollddeerr OOppttiioonnss –– SSiiddee BBrriiddggee........................................................................................................................................................................................................ 1122 TTuubbee HHoollddeerr OOppttiioonnss –– SSiiddee BBrriiddggee........................................................................................................................................................................................................ 1144 TTuubbee HHoollddeerr OOppttiioonnss -- SSwwiinngg.............................................................................................................................................................................................................................. 1155 TTuubbee HHoollddeerr OOppttiioonnss -- SSwwiinngg.............................................................................................................................................................................................................................. 1166 CCeennttrriiffuuggee TTuubbee HHoollddeerr OOppttiioonnss –– SSwwiinngg .................................................................................................................................................................................. 1177 VViiaall HHoollddeerr OOppttiioonnss –– SSiiddee BBrriiddggee.............................................................................................................................................................................................................. 1188 VViiaall HHoollddeerr OOppttiioonnss –– SSiiddee BBrriiddggee.............................................................................................................................................................................................................. 1199 VViiaall HHoollddeerr OOppttiioonnss –– SSiiddee BBrriiddggee.............................................................................................................................................................................................................. 2200 VViiaall HHoollddeerr OOppttiioonnss –– SSwwiinngg.................................................................................................................................................................................................................................. 2211
Microplate Heat Transfer Plates ..............................................................................23 MMiiccrrooppllaattee HHeeaatt TTrraannssffeerr PPllaatteess .................................................................................................................................................................................................................... 2244
Mega Series Evaporators...........................................................................................25 GGiillssoonn RRaacckkss FFoorr CCeennttrriiffuuggaall AApppplliiccaattiioonnss.................................................................................................................................................................................. 2266 Designed and Manufactured by Genevac Ltd. in Agreement With Gilson Inc........................... 26 MMeeggaa FFaasstt--SSttaacckk RRaacckkss ........................................................................................................................................................................................................................................................ 2277
Waters Fraction Collection Racks............................................................................29 WWaatteerrss FFrraaccttiioonn CCoolllleeccttiioonn RRaacckkss.............................................................................................................................................................................................................. 3300
Miscellaneous..............................................................................................................31 MMiisscceellllaanneeoouuss........................................................................................................................................................................................................................................................................................ 3322
SampleGuard Temperature Probe ..........................................................................32 SampleGuard Temperature Probe Locator............................................................32
MMiisscceellllaanneeoouuss........................................................................................................................................................................................................................................................................................ 3333 Remote Lid Switch.....................................................................................................33
IInneerrtt GGaass PPuurrggee ((SSmmaarrtt BBooxx)).................................................................................................................................................................................................................................. 3344 TThheerrmmaall CCuusshhiioonn .......................................................................................................................................................................................................................................................................... 3355 TThheerrmmaall CCuusshhiioonn .......................................................................................................................................................................................................................................................................... 3366 SSaammppllee HHoollddeerr PPaarrtt NNuummbbeerr IInnddeexx .......................................................................................................................................................................................................... 3377 SSaammppllee HHoollddeerr PPaarrtt NNuummbbeerr CCrroossss RReeffeerreennccee ................................................................................................................................................................ 3377 SSwwiinngg PPaarrtt NNuummbbeerr CCrroossss RReeffeerreennccee .................................................................................................................................................................................................. 3377
NotesNotes Amendment Control Form.................................................................38 Notes Amendment Control Form ...........................................................................39 Amendment Control Form.......................................................................................40
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 3
IInnttrroodduuccttiioonn Genevac evaporators are designed to combine rapid and safe evaporation with high capacity and a wide variety of sample formats. In order to optimise the evaporation performance achieved it is important to select the correct sample holder for your particular application. Genevac samples holders are manufactured from solid aluminium to very precise specifications and are mass balanced to ensure smooth running of the evaporator. This guide will help you make the right choice. NNeeww RRaannggee This guide covers the new range of Genevac sample holders. These holders are easily identifiable as they are coloured bright blue. Any Genevac sample holder which is coloured blue can be used in both the HT series II systems and the EZ-2 series, this was not the case with the old range. Blue holders are not compatible with the old range of holders, to help you choose the correct new holder a cross referenced list can be found on page 33. Should you require an old design of holder, or a holder for a tube not listed, please contact your local Genevac representative or sales agent. Holders that are only to be used in the EZ-2, are identified in this brochure with the following; EZ-2 ONLY. Holders that are only to be used in the HT Series II, are identified in this brochure with the following; HT Series II ONLY. Some holders may not be used in EZ-2 mk1. The EZ-2 mk1 can be easily identified by the large circular window in the chamber lid, EZ-2 mk2 has a solid lid with a small ‘tear drop’ window. These holders are identified in the brochure with the following: NOT EZ-2 mk1. DDeeffiinniittiioonnss GGeeoommeettrryy 1 Tube holder indicates that the sample holder is designed to accommodate a
tube with a hemispherical end. 2 A vial or bottle holder indicates that the sample holder is designed to
accommodate a vial or bottle with a flat end. 3 Tubes with conical or tapered ends are individually identified
Options and Accessory Brochure
Page 4 10-1478 Issue 4-9 January 2009
FFaaccttoorrss aaffffeeccttiinngg eevvaappoorraattiioonn ppeerrffoorrmmaannccee HHeeaatt ttrraannssffeerr One of the major factors determining speed of evaporation is the rate at which heat is transferred to your sample. More heat transferred means faster evaporation. These are the ways that the EZ-2, HT series II, DD-4, R-4 and Mega evaporators give you the best heat transfer: 1 High quality aluminium rotors and holders. Aluminium is recommended for
its properties of high thermal conductivity and low weight. Genevac systems use aluminium sample holders, which have particularly efficient heat transfer properties.
2 High quality engineering. Genevac samples holders are manufactured to very
precise specifications. This means your tubes fit very snugly into the tube holders. Any gaps would slow down the rate of heat transfer. For this reason it is important you send us a sample of your tube when placing orders for sample holders.
PPrrootteeccttiivvee ccooaattiinnggss SSaammppllee hhoollddeerrss Standard aluminium sample holders are “Hard Anodised (naturally unsealed)” for protection against all normal organic solvents, including strong acids such as TFA. HHCCll oorr TThhiioonnyyll CChhlloorriiddee When evaporating HCl or Thionyl Chloride it will be necessary to purchase both a HCl/Thionyl Chloride resistant system (comprising of: evaporator, condenser and pump) and HCl/Thionyl Chloride resistant sample holders. In this case the aluminium rotor and sample holders are coated to ensure resistance to attack from HCl/Thionyl Chloride. MMaaxxiimmuumm CCaappaacciittyy Genevac uses the latest in computer aided design technology to ensure internal capacity is maximised whilst the instrument footprint is kept to an absolute minimum. This means high throughput evaporation is possible from an instrument taking up a small amount of bench top space.
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 5
MMiinniimmiissiinngg TTuubbee BBrreeaakkaaggee Not only does precision design of Genevac sample holders contribute to excellent heat transfer and superior evaporation performance, it also ensures that tubes have maximum protection from breakage during evaporation. For additional protection against glassware breakage, some flask holders and some tube holders are provided with thermal cushions. Thermal cushions are made from a filled polymer with excellent heat transfer and cushioning properties. Only borosilicate tubes with wall thickness more than 1.2mm should be used in Genevac evaporators. Old, damaged or scratched glassware should not be used. Laboratories that reuse tubes or vials should regularly inspect each tube or vial for damage, and discard scratching or cracked items. For more information and advice on this subject, please refer to our “Safe Loading” document available to download from our web site. MMaaiinntteennaannccee Regular inspection and maintenance of sample holders should be performed at least monthly. The following inspection routine is mandatory following tube breakage or solvent spillage. Never use wet sample holders in a Genevac system. Inspection: Visually inspect and sample holders each month. Debris - should be cleaned off, especially any in the sample holder wells as this may lead to glassware breakage. The number one cause of repeat glassware breakage is glass fragments from a previously broken tube. Sometimes the sample sticks the glass to the inside of a sample holder well and it is therefore difficult to remove. Residual solvent / sample - should be cleaned off. Superficial surface damage (e.g. scratches) will not affect the performance of a sample holder. If a sample holder is structurally damaged, (any part of the sample holder bent of deformed) - do not use - contact Genevac for evaluation. Cleaning: Loose dirt / debris can be removed using a brush and / or airline. Adhered dirt / debris or sample / solvent residue should be cleaned off using methanol or acetone, soaking the sample holders if required. The sample holders should then be washed in clean water and fully dried before use.
Options and Accessory Brochure
Page 6 10-1478 Issue 4-9 January 2009
CCuussttoomm DDeessiiggnn ffoorr SSppeecciiaall AApppplliiccaattiioonn As the market leader in centrifugal evaporation, we have already designed holders for the majority of applications. Please examine the list on the following pages, for the correct part number.
However, should you have a special application or unusual tube size then we can design a special holder for you. Please note there is a nominal charge to cover design time for this service. Our experienced sales team (or international distributors) will be pleased to advise you of the options available. RRoottoorrss For information on our rotors, please refer to the “Quick Guide to HT Series Rotors” available to download from our web site.
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 7
HHTT SSeerriieess && EEZZ--22 EEvvaappoorraattoorrss
Options and Accessory Brochure
Page 8 10-1478 Issue 4-9 January 2009
FFaasstt--SSttaacckk BBuucckkeett OOppttiioonnss
Holder Description Specification (Diameter x Length)
Part number
Shallow Well
(Minimum Order Qty 2)
Holds 4 microtitre plates.
Max area for plate: 128.0 x 86.5 x 19.0 (mm)
Mass = 523g
70-0092
Deep Well
HCl use
(Minimum Order Qty 2)
Holds 2 Micro-Tube Cluster Racks.
Max area for plate: 129.0 x 86.5 x 48.5 (mm)
Mass = 580g
70-0959
NOT EZ-2 mk1
Side Bridge
HCl use
(Minimum Order Qty 2)
Holds Radleys GreenHouse Block
Max foot-print: 128.0 x 86.5 (mm)
Mass = 380g
70-0578
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 9
FFllaasskk HHoollddeerr OOppttiioonnss --SSwwiinngg
Holder Description Specification (Diameter x Length)
Part number
Round Bottom
Flask Holder
(Minimum Order Qty 2)
Holds Qty 6 x 25ml (19/26 – 24/29 Socket Size)
(See Note Below) 70-0538
British Design Registration No. 3008735
Round Bottom
Flask Holder
(Minimum Order Qty 2)
Holds Qty 4 x 50ml (29/32 Socket Size)
(See Note Below)
70-0539
British Design Registration No. 3008735
Round Bottom
Flask Holder
(Minimum Order Qty 2)
Holds Qty 4 x 50ml (19/26 - 24/29 Socket Size)
(See Note Below)
70-0656
British Design Registration No. 3008737
Round Bottom
Flask Holder
(Minimum Order Qty 2)
Holds Qty 3 x 100ml (19/26 - 24/29 Socket Size)
(Including Radleys Carousel)
(See Note Below)
70-0657
EZ-2 ONLY
British Design Registration No. 3008737
Round Bottom
Flask Holder
(Minimum Order Qty 2)
Holds Qty 3 x 100ml (29/32 Socket Size)
(See Note Below)
70-0579
EZ-2
ONLY
Note: Must be used with Genevac Thermal Cushion for prolonging glassware
lifetimes and dramatically cutting drying times.
Options and Accessory Brochure
Page 10 10-1478 Issue 4-9 January 2009
FFllaasskk HHoollddeerr OOppttiioonnss --SSwwiinngg
Holder Description Specification (Diameter x Length)
Part number
British Design Registration No. 3008739
Round Bottom
Flask Holder
(Minimum Order Qty 2)
Holds Qty 1 x 250ml (19/26 - 24/29 – 29/32 Socket Size)
(Including Radleys Carousel)
(See Note Below)
70-0580
British Design Registration No. 3008740
Round Bottom
Flask Holder
(Minimum Order Qty 2)
Holds Qty 1 x 500ml (19/26 - 24/29 – 29/32 Socket Size)
(See Note Below)
70-0582
EZ-2
ONLY
Round Bottom
Flask Holder
(Minimum Order Qty 2)
Holds Qty 1 x 500ml Max Flask height – 156mm
(See Note Below)
10-1616
HT
Series II ONLY
Note: Must be used with Genevac Thermal Cushion for prolonging glassware
lifetimes and dramatically cutting drying times.
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 11
BBoottttllee//BBeeaakkeerr HHoollddeerr OOppttiioonnss --SSwwiinngg
Holder Description Specification (Diameter x Length)
Part number
Bottle Holder
(Minimum
Order Qty 2)
Holds Qty 2 x 100ml Schott bottles 70-1025
Bottle/Beaker Holder
(Minimum
Order Qty 2)
Holds Qty 1 x 250ml Schott bottle
or 1 x 400ml beaker
(Fisher Brand ref FB33124) 70mm x 130mm
10-5060
Bottle/Beaker Holder
(Minimum
Order Qty 2)
Holds Qty 1 x 500ml Glass bottle
82mm x 152mm
(See Note Below)
10-5063
NOT EZ-2 mk1
Note: Must be used with Genevac Thermal Cushion for prolonging glassware
lifetimes and dramatically cutting drying times.
Options and Accessory Brochure
Page 12 10-1478 Issue 4-9 January 2009
TTuubbee HHoollddeerr OOppttiioonnss –– SSiiddee BBrriiddggee
Holder Description Specification (Diameter x Length)
Part number
0.5ml Eppendorf
holder
(Minimum Order Qty 2)
Holds Qty 50 10-5049
1.5ml Eppendorf
holder
(Minimum Order Qty 2)
Holds Qty 32 10-5043
Tube Holder
(Minimum Order Qty 2)
Holds Qty 40 10mm x 75mm 10-5000
Tube Holder
(Minimum Order Qty 2)
Holds Qty 40 12mm x 75mm 10-5025
Tube Holder
(Minimum Order Qty 2)
Holds Qty 40 12mm x 75 to 110mm 10-5001
Tube Holder
(Minimum Order Qty 2)
Holds Qty 40 13mm x 75 to 110mm 10-5002
Tube Holder
(Minimum Order Qty 2)
Holds Qty 24 16mm x 75 to 110mm 10-5004
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 13
Tube Holder
(Minimum Order Qty 2)
Holds Qty 24 17mm x 75 to 110mm Straight “Microwave”
10-5005
Options and Accessory Brochure
Page 14 10-1478 Issue 4-9 January 2009
TTuubbee HHoollddeerr OOppttiioonnss –– SSiiddee BBrriiddggee
Holder Description Specification (Diameter x Length)
Part number
Tube Holder
(Minimum Order Qty 2)
Holds Qty 24 17mm x 85mm
Tapered “Microwave” 10-5042
Tube Holder
(Minimum Order Qty 2)
Holds Qty 24 18mm x 75mm to 110mm 10-5006
Tube Holder
(Minimum Order Qty 2)
Holds Qty 12 25mm x 75mm to 110mm 10-5009
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 15
TTuubbee HHoollddeerr OOppttiioonnss -- SSwwiinngg
Holder Description Specification (Diameter x Length)
Part number
Tube Holder
(Minimum Order Qty 2)
Holds Qty 20 16.5mm x 130mm
10-5050
Tube Holder
(Minimum Order Qty 2)
Holds Qty 12 17mm x 110mm to
152mm
10-5022
Tube Holder
(Minimum Order Qty 2)
Holds Qty 12 18mm x 110mm to
152mm 10-5015
Tube Holder
(Minimum Order Qty 2)
Holds Qty 10 20mm x 110mm to
152mm 10-5023
Tube Holder
(Minimum Order Qty 2)
Holds Qty 6 24mm x 110mm to
152mm (Including
Radleys Carousel and STEM Reaction Stations)
10-5026
Options and Accessory Brochure
Page 16 10-1478 Issue 4-9 January 2009
TTuubbee HHoollddeerr OOppttiioonnss -- SSwwiinngg
Holder Description Specification (Diameter x Length)
Part number
Tube Holder
(Minimum Order Qty 2)
Holds Qty 6 25mm x 110mm to
152mm 10-5027
Tube Holder
(Minimum Order Qty 2)
Holds Qty 3 34mm x 135mm 10-5051
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 17
CCeennttrriiffuuggee TTuubbee HHoollddeerr OOppttiioonnss –– SSwwiinngg
Holder Description Specification (Diameter x Length)
Part number
15ml Tube Holder
(Minimum
Order Qty 2)
Holds Qty 24 16.5mm x 120mm 10-5053
50ml Tube Holder
(Minimum
Order Qty 2)
Holds Qty 10 28.5mm x 115mm
70 Degree End 10-5054
Options and Accessory Brochure
Page 18 10-1478 Issue 4-9 January 2009
VViiaall HHoollddeerr OOppttiioonnss –– SSiiddee BBrriiddggee
Holder Description Specification (Diameter x Length)
Part number
Vial Holder
(Minimum Order Qty 2)
Holds Qty 48 10mm x 45mm 10-5029
Vial Holder
(Minimum Order Qty 2)
Holds Qty 48 12mm x 35mm 10-5024
Vial Holder
(Minimum Order Qty 2)
Holds Qty 40 13mm x 50mm
(4ml HPLC CRIMP TOP VIAL) 10-5034
Vial Holder
(Minimum Order Qty 2)
Holds Qty 24 14.5mm x 50mm 10-5035
Vial Holder
(Minimum Order Qty 2)
Holds Qty 24 15mm x 50mm 10-5037
Vial Holder
(Minimum Order Qty 2)
Holds Qty 24 15.5mm x 50mm
(1 DRAM & 4ml HPLC SCREW TOP VIAL)
10-5038
Vial Holder
(Minimum Order Qty 2)
Holds Qty 24 16.5mm x 75mm 10-5028
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 19
VViiaall HHoollddeerr OOppttiioonnss –– SSiiddee BBrriiddggee
Holder Description Specification (Diameter x Length)
Part number
Vial Holder
(Minimum Order Qty 2)
Holds Qty 24 17mm x 75mm
(2 DRAM VIAL) 10-5030
Vial Holder
(Minimum Order Qty 2)
Holds Qty 24 17.5mm x 50mm 10-5031
Vial Holder
(Minimum Order Qty 2)
Holds Qty 18 20mm x 75mm 10-5036
Vial Holder
(Minimum Order Qty 2)
Holds Qty 18 20.5mm x 75mm
10-5040
Vial Holder
(Minimum Order Qty 2)
Holds Qty 12 23mm x 75mm
10-5019
Vial Holder
(Minimum Order Qty 2)
Holds Qty 12 24mm x 75mm
10-5014
Vial Holder
(Minimum Order Qty 2)
Holds Qty 12 27.5mm x 75mm
(20ml SCINTILLATION VIAL) 10-5013
Options and Accessory Brochure
Page 20 10-1478 Issue 4-9 January 2009
VViiaall HHoollddeerr OOppttiioonnss –– SSiiddee BBrriiddggee
Holder Description Specification (Diameter x Length)
Part number
Vial Holder
(Minimum Order Qty 2)
Holds Qty 8 27.5mm x 75 to 110mm (40ml SCINTILLATION VIAL)
10-5010
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 21
VViiaall HHoollddeerr OOppttiioonnss –– SSwwiinngg
Holder Description Specification (Diameter x Length)
Part number
Vial Holder
(Minimum Order Qty 2)
Holds Qty 6 27.5mm x 95 & 142mm
10-5017
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 23
MMiiccrrooppllaattee HHeeaatt TTrraannssffeerr PPllaatteess
Not only can Genevac offer precision manufactured sample holders providing excellent evaporation results for laboratory glassware, there is a range of sample holders that improve evaporation when using deep well microtitre plates. These holders, Heat Transfer Plates, are designed to support the wells of the plate, to fit precisely to the base of the wells, and where possible, to fit to the sides of each well. Heat transfer plates confer two main benefits:
• Excellent heat transfer rates, and reduced evaporation times from micro plates by up to 50% - for more details view the study available on the Genevac website using the following link:
http://www.genevac.com/presentations/traditional/index.html
• Support for micro plates when used in open swings, preventing direct heating by lamps that may be harmful, and preventing plates becoming deformed by heat and G-force.
Heat transfer plates are available for use in open swings, side bridge swings, and most Fast Stack holders. Heat transfer plates MUST be used when using microtube cluster racks, e.g. Micronics or ABgene racks, in Genevac open swings. If you would like a micro plate evaluated to see if a suitable Heat Transfer Plate exists, or would like further information, please contact your Genevac representative.
Options and Accessory Brochure
Page 24 10-1478 Issue 4-9 January 2009
MMiiccrrooppllaattee HHeeaatt TTrraannssffeerr PPllaatteess
Plate Description Specification Part number
For use in Side Bridge
Swing
(Minimum Order Qty 2)
Provides an even sample drying condition. Max foot-print:
128.0 x 86.5 (mm) Mass = 200g
70-0086
Ex-Stock
Patent applied for in the UK and worldwide
For use in Side Bridge
Swing
(Minimum Order Qty 2)
Compatible with:
Falcon, Micronic Traxis and Micronic Multi-Tube
Cluster Racks
Round end tubes
70-0084
Special order
Patent applied for in the UK and worldwide
For use in Side Bridge
Swing
(Minimum Order Qty 2)
Compatible with:
Beckman 1ml x 96 O Beckman 2ml x 96 Costar 1ml x 96 O Costar 2ml x 96
Whatman 2ml x 96
70-0085
Special order
Patent applied for in the UK and worldwide
For use in Side Bridge
Swing
(Minimum Order Qty 2)
Compatible with:
Axygen 2ml x 96 O Greiner 1ml x 96 O Nunc 2ml x 96 O Nunc 1ml x 96 O
Whatman 1ml x 96 O
70-0087
Special order
Patent applied for in the UK and worldwide
For use in Deep Well
Swing
(Minimum Order Qty 2)
Compatible with:
MultiChem 10ml x 24 O Polyfiltronics 10ml x 24 O
UniPlates 10ml x 24 O Whatman 10ml x 24 O
70-0357
Special order
Patent applied for in the UK and worldwide
For use in Deep Well
Swing
(Minimum Order Qty 2)
Compatible with:
ABgene Multi-Tube Cluster Racks
Round end tubes
70-0361
Special order
The items listed above are only a small example from the range of Heat Transfer Plates that Genevac can provide; please contact your Sales representative for details.
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 25
MMeeggaa SSeerriieess EEvvaappoorraattoorrss
Options and Accessory Brochure
Page 26 10-1478 Issue 4-9 January 2009
GGiillssoonn RRaacckkss FFoorr CCeennttrriiffuuggaall AApppplliiccaattiioonnss DDeessiiggnneedd aanndd MMaannuuffaaccttuurreedd bbyy GGeenneevvaacc LLttdd.. iinn AAggrreeeemmeenntt WWiitthh GGiillssoonn IInncc..
Holder Description & Gilson Code Specification (Diameter x Length)
Part number
Tube holder
(Code 207)
Holds Qty 75 16 x 100 mm
10-1269
Special order
Tube holder
(Code 223)
Holds Qty 96 16 x 100 mm
10-1499
Special order
Scintillation vials holder
(Code 204)
Holds Qty 27 28 x 57 mm
10-1287
Special order
Tube holder
(Code 204)
Holds Qty 27 28 x 100 mm
10-1268
Special order
Scintillation vials holder
(Code 204)
Holds Qty 27 28 x 100 mm
10-1285
Special order
Centrifuge tube holder
(Code 222)
Holds Qty 27 50ml
10-1272
Special order
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 27
MMeeggaa FFaasstt--SSttaacckk RRaacckkss
Applicability Specification (Quantity and Type)
Part number
Mega 980 Max
Holds Qty 28 Shallow Well Micro Plates
70-0418
Special order
Mega 980 Max
Holds Qty 16 Deep Well
Micro Plates
70-0417
Special order
Mega 980 Max
Holds Qty 10 Marsh
Micro Plates
10-1373
Special order
Mega 1200 Max
Holds Qty 50 Shallow Well Micro Plates
10-1370
Special order
Mega 1200 Max
Holds Qty 30 Deep Well
Micro Plates
70-0439
Special order
Mega 1200 Max
Holds Qty 20 Marsh
Micro Plates
10-1353
Special order
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 29
WWaatteerrss FFrraaccttiioonn CCoolllleeccttiioonn RRaacckkss Genevac offer a range of innovative options that help interface your fraction collection system directly to the Genevac HT series evaporator. Currently Gilson 215 and Waters 2767 systems are supported. To interface with the fraction collections system, Genevac provide a simple sample holder carrier which fits directly on to the fraction collection bed. Genevac sample holders fit into the carrier to make up a complete fraction collection rack. Once fractions have been collected, the sample holders can be placed directly into the Genevac evaporator with no need to label, mark or manipulate each tube. Sample holders can be marked to indicate location within the fraction collection rack. There are a range of options, some use standard sample holders, some use specially designed holders which keep the spacing between tubes uniform, and reduce fraction collector reprogramming. Waters 2767 users will require the adaptor plate when using 16mm diameter tubes. A separate range of Genevac designed holders exists for use with Genevac Mega systems (see page 22). A technical article discussing these issues in greater detail is available upon request from your Genevac representative. If you would like further information, please contact your Genevac representative.
Options and Accessory Brochure
Page 30 10-1478 Issue 4-9 January 2009
WWaatteerrss FFrraaccttiioonn CCoolllleeccttiioonn RRaacckkss
Description Specification Part number
Adapter Plate For rack 10-1570
Converts Waters 2767 Sample Manager Rack Bed
from 4 to 3 Racks
04-4181
Special order
Rack for use with
Waters Fraction
Collection
Holds Qty 4 10-5020 or 10-5027 Tube
Holders
10-1570
Special order
Tube Holder
(Minimum Order Qty 2)
Holds Qty 12 16mm x 110mm to
152mm
10-5020
Special order
Tube Holder
(Minimum Order Qty 2)
Holds Qty 6 25mm x 110mm to
152mm
10-5027
Special order
Adapter plate For
SideBridge Holders
Converts Waters 2767 Sample Manager Rack Bed
To enable 14 MAX SideBridge Holders
To be loaded
04-4330
Special order
SideBridge Vial Holder
(Minimum Order
Qty 2)
Holds Qty 12 20ml Scintillation Vials
10-5013
Special order
The items listed above are only a small example from the range that Genevac can provide; please contact your Sales representative for details.
Options and Accessory Brochure
Page 32 10-1478 Issue 4-9 January 2009
MMiisscceellllaanneeoouuss
Description Specification Part number
NOT ILLUSTRATED SSaammpplleeGGuuaarrdd TTeemmppeerraattuurree
PPrroobbee
MkIV Rotor
Length 90mm – Standard
Length 90mm – HCl
70-0161
70-0196
NOT ILLUSTRATED
SampleGuard Temperature
Probe
CH1 & CH2 Short
FastStack Swing Solid Holder
Length 160mm – Standard
Length 160mm – HCl
70-0163
70-0197
NOT ILLUSTRATED SampleGuard Temperature
Probe
CH2 Medium
Length 220mm – Standard
Length 220mm – HCl
70-0168
70-0200
NOT ILLUSTRATED
SampleGuard Temperature
Probe
CH2 Long
Length 280mm – Standard
Length 280mm – HCl
70-0210
70-0212
SSaammpplleeGGuuaarrdd TTeemmppeerraattuurree PPrroobbee LLooccaattoorr
For use with Micro Plates On Request
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 33
MMiisscceellllaanneeoouuss
Description Specification Part number
NOT ILLUSTRATED
RReemmoottee LLiidd SSwwiittcchh
For use with HT-4 when fitted in fume hood 70-0158
Options and Accessory Brochure
Page 34 10-1478 Issue 4-9 January 2009
IInneerrtt GGaass PPuurrggee ((SSmmaarrtt BBooxx))
Description Specification Part number
Inert Gas Purge Box
For use with HT-4 Series II Evaporators
70-0177
Special order
Inert Gas Purge Box
For use with HT-8 & 12 Series II
Evaporators
70-0309
Special order
Inert Gas Purge Box
For use with EZ-2 100Volt Evaporators
70-0776
Special order
Inert Gas Purge Box
For use with EZ-2 120 Volt Evaporators
70-0726
Special order
Inert Gas Purge Box
For use with EZ-2 230 Volt Evaporators
70-0725
Special order
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 35
TThheerrmmaall CCuusshhiioonn
Description Specification Part number
Thermal Cushion
Use with 25ml Flask
(Pack of 96)
10-1551
Ex-Stock
Thermal Cushion
Use with 50ml Flask
(Pack of 96)
10-1556
Ex-Stock
Thermal Cushion
Use with 100ml Flask (Pack of 48)
10-1555
Ex-Stock
Thermal Cushion
Use with 170/250ml Flask
(Pack of 48)
10-1554
Ex-Stock
Thermal Cushion
Use with 250ml Flask (Pack of 12)
10-1553
Ex-Stock
Thermal Cushion
Use with 500ml Flask (Pack of 12)
10-1552
Ex-Stock
Options and Accessory Brochure
Page 36 10-1478 Issue 4-9 January 2009
TThheerrmmaall CCuusshhiioonn
Description Specification Part number
Applicator For use with
Thermal Cushion 04-3822
Ex-Stock
Spatula For use with Thermal Cushion
04-3869
Ex-Stock
Options and Accessory Brochure
10-1478 - Issue 4-9 January 2009 Page 37
SSaammppllee HHoollddeerr PPaarrtt NNuummbbeerr IInnddeexx 10-1616....................... 10 10-5000....................... 16 10-5001....................... 12 10-5002....................... 12 10-5004....................... 12 10-5005....................... 12 10-5006....................... 13 10-5009....................... 13 10-5010....................... 19 10-5013....................... 18 10-5014....................... 18 10-5015....................... 14 10-5017....................... 20 10-5019....................... 18 10-5020....................... 27 10-5022....................... 14
10-5023 ...................... 14 10-5024 ...................... 21 10-5025 ...................... 12 10-5026 ...................... 14 10-5027 ...................... 15 10-5028 ...................... 21 10-5029 ...................... 21 10-5030 ...................... 18 10-5031 ...................... 18 10-5034 ...................... 21 10-5035 ...................... 21 10-5036 ...................... 18 10-5037 ...................... 21 10-5038 ...................... 21 10-5040 ...................... 18 10-5042 ...................... 13
10-5043 ...................... 12 10-5049 ...................... 12 10-5050 ...................... 14 10-5051 ...................... 15 10-5053 ...................... 20 10-5054 ...................... 20 10-5060 ...................... 11 70-0538 .........................9 70-0539 .........................9 70-0579 .........................9 70-0580 ...................... 10 70-0582 ...................... 10 70-0656 .........................9 70-0657 .........................9 70-1025 ...................... 11
SSaammppllee HHoollddeerr PPaarrtt NNuummbbeerr CCrroossss RReeffeerreennccee
Old New ............... 10-1616
70-0005............... 10-5037 70-0007............... 10-5035 70-0008............... 10-5049 70-0019............... 10-5024 70-0024............... 10-5031 70-0052............... 10-5043 70-0055............... 10-5019 70-0072............... 10-5028 70-0073............... 10-5029 70-0538............... 70-0539............... 70-0550............... 10-5053 70-0551............... 10-5054 70-0579...............
Old New 70-0580................ 70-0582................ 70-0633................10-5014 70-0646................10-5051 70-0656................ 70-0657................ 70-0660................10-5025 70-0661................10-5001 70-0663................10-5002 70-0665................10-5004 70-0666................10-5006 70-0667 ...............10-5027 70-0668................10-5015 70-0669................10-5023 70-0670................10-5026 70-0671................10-5027
Old New 70-0673................10-5034 70-0674................10-5038 70-0675................10-5030 70-0676................10-5013 70-0719................10-5036 70-0720................10-5009 70-0724................10-5010 70-0759................10-5040 70-0777................10-5005 70-0778................10-5022 70-0780................10-5020 70-0794................10-5050 70-0928................10-5042 ................10-5017 70-1025................ ................10-5060
SSwwiinngg PPaarrtt NNuummbbeerr CCrroossss RReeffeerreennccee
Old New 70-0001............... 70-0959 70-0091............... 70-0578 70-0093............... 70-0578 70-0110............... 70-0578 70-0354............... 70-0959 70-0620............... 70-0959
Options and Accessory Brochure
Page 40 10-1478 Issue 4-9 January 2009
AAmmeennddmmeenntt CCoonnttrrooll FFoorrmm
Issue Reason for Change Date Issued 1 Introduction of 500ml Flask Holder for HT Series II 30-Nov-05
2 Corrected image for 10-5042 31-Jul-06
3 Introduction of Schott Bottle & Beaker holders 13-Nov-06
4 Waters Fraction Collection Rack – Options updated 20-Aug-07
5 Addition of tube holder 10-5000 31-Jan-08
6 Addition of Maintenance of Sample Holder 17-Apr-08
4-7 Update U.S. address 24-Oct-08
4-8 Amend layout 16-Jan-09
4-9 Correct title Centrifuge Tube Holder Options – Swing 27-Jan-09
Genevac Limited The Sovereign Centre
Farthing Road Ipswich IP1 5AP
United Kingdom
Sales and Service Hotlines
Service Hotline: +44 (0) 1473 243000
Sales Hotline: +44 (0) 1473 240000
Fax: +44 (0) 1473 461176
EEmmaaiill:: mmaaiillttoo::ssaalleessiinnffoo@@ggeenneevvaacc..ccoo..uukk
Web site: http://www.genevac.com
Genevac Inc SP Industries
815 State Route208 Gardiner
NY, 12525 United States of America
Sales and Service Hotline
(1) 845 267 2212
Fax (1) 845 267 2212
EEmmaaiill:: ssaalleessiinnffoo@@ggeenneevvaaccuussaa..ccoomm
Genevac Technology is protected by patents and patent applications in the UK and worldwide. Genevac Ltd has a continuous development programme aimed at further improving their products and all specifications are, therefore, subject to change. Coolheat®, VacRampTM (Dri-Pure®), SampleGuardTM and associated logos are trade marks of
Genevac Ltd, unauthorised use is prohibited.