1Apr. 28, 2007
Test of the Pulse Height and Time Jitterfor the IHEP Full-Size RPC’s
with 8-m-Long Readout Strip Planes
C. Lu, K. McDonald and W. Sands
Princeton University
2Apr. 28, 2007
4-Layer RPC Stack
3Apr. 28, 2007
Planar Arrays of Chambers
Mount chambers in 4 planes, staggered to maintain high efficiency.
Readout in 4 quadrants with 9-m-long readout strips.
All electronics at the edge of the array.
Simplified mechanics of chamber mounting.
4Apr. 28, 2007
Effect on Efficiency
Dead regions between adjacent chambers in one plane 3% reduction in efficiency of that plane (95% 92%).
With staggering of different planes, correlated inefficiency between a pair of planes will be ~ 0.1%.
3 out of 4 trigger efficiency is 96.5% (down from 98.6%).
5Apr. 28, 2007
Readout via Long Transmission Lines
Long readout strips act as transmission lines signal quality independent of position if strips properly terminated.
Lab tests confirm this (rest of this presentation).
If strip width remains at nominal 25 cm, can reduce number of readout channels by factor of 4.
(Or, can increase position resolution by factor of 4 if keep channel count the same.)
6Apr. 28, 2007
Test setup
IHEP single gap RPC chamber
Readout strip
Rigid honeycomb panel (1/2” thick)
Al sheet underneath of the honeycomb as ground shielding and strip signal return plane.
Al foil to shield the 8m long strip plane.
7Apr. 28, 2007
Flexible readout strip band
This is Belle readout strip band, can make large roll of this material.
8Apr. 28, 2007
Honeycomb panel
½” thick honey comb panel, very rigid, surprisingly its dielectric constant is ~3.80.
9Apr. 28, 2007
Signal shape
R1=165Ω,R2=38Ω
RPC1 HV ON
R1=165Ω,R2=2Ω
RPC1 HV ON
R1=165Ω,R2=12Ω
RPC1 HV ON
Terminator’s effect on the signal’s shape
10Apr. 28, 2007
Test TDC and ADC simultaneously
Use CAMAC TDC and charge sensitive ADC modules to test the 8m long strip readout signal.
11Apr. 28, 2007
Meantimer Time spectrum
The trigger counters are 1m long, therefore the TDC start signal has intrinsic time jitter. We use LeCroy Meantimer modules to eliminate this jitter. Two trigger counters are overlapped, their outputs enter the LeCroy meantimer, its output signal corresponds to the signal initiated at the middle of the counter.
10ns/division
Input #1 of the meantimer
Input #2 of the meantimer
Triggered by output of the meantimer
12Apr. 28, 2007
Trigger counters at far end of the strip plane
First we place the trigger counters at the far end of the readout strip plane. Near and far end trigger arrangements are shown below:
13Apr. 28, 2007
Screen capture of the strip signal
80ns/div
50mV/div
The screen captures on the left show several sequentially captured trigger events w/o any other selection.
14Apr. 28, 2007
TDC and QDC spectrum
We used a LeCroy TDC module and a Phillips QDC module to measure the time and charge spectrum of the full size RPC chamber.
Put the trigger counters at the far end of the strip plane.
The time jitter for a 1m long section of RPC is ~6.5ns
15Apr. 28, 2007
Trigger counters at near end of the strip plane
Screen captures of strip signal for trigger counters at the near end.
16Apr. 28, 2007
TDC and QDC spectrum
(1 ch = 0.125pC)
17Apr. 28, 2007
Peak sensing ADC module test results
0
50
100
150
200
250
0 500 1000 1500 2000
TDC(ch)
TDC, 7400VMean=1041 chSigma=155 ch
0
50
100
150
200
0 500 1000 1500 2000
TDC, 7600VMean=971chSigma=110ch
0
50
100
150
200
250
300
350
0 500 1000 1500 2000
TDC, 7800Vt=928chs=96.5ch
Change HV setting, keep other electronics system fixed, we can see that ADC peak is shifting towards right, and TDC peak is shifting towards left while raising HV from 7400V to 7800V.
ADC calibration:
PH(mV)=(ADC(mV)+31)/0.7
18Apr. 28, 2007
Correlation between ADC and TDC
0
500
1000
1500
2000
2500
0 500 1000 1500 2000
ADC
TDC
7800V
0
500
1000
1500
2000
2500
0 500 1000 1500 2000 2500
ADC
TDC
7400V
Plot the scatter plot of ADC vs TDC, we found that TDC is quite constant. It does not depend on the ADC reading:
0
500
1000
1500
2000
2500
0 500 1000 1500 2000 2500
ADC
TDC
7600V
19Apr. 28, 2007
OPERA RPC system uses 8m long readout strip plane, the following pages show few steps of their installation procedure and the dimension of their strip plane.