24
1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands Princeton University

1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

  • View
    219

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

1Apr. 28, 2007

Test of the Pulse Height and Time Jitterfor the IHEP Full-Size RPC’s

with 8-m-Long Readout Strip Planes

C. Lu, K. McDonald and W. Sands

Princeton University

Page 2: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

2Apr. 28, 2007

4-Layer RPC Stack

Page 3: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

3Apr. 28, 2007

Planar Arrays of Chambers

Mount chambers in 4 planes, staggered to maintain high efficiency.

Readout in 4 quadrants with 9-m-long readout strips.

All electronics at the edge of the array.

Simplified mechanics of chamber mounting.

Page 4: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

4Apr. 28, 2007

Effect on Efficiency

Dead regions between adjacent chambers in one plane 3% reduction in efficiency of that plane (95% 92%).

With staggering of different planes, correlated inefficiency between a pair of planes will be ~ 0.1%.

3 out of 4 trigger efficiency is 96.5% (down from 98.6%).

Page 5: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

5Apr. 28, 2007

Readout via Long Transmission Lines

Long readout strips act as transmission lines signal quality independent of position if strips properly terminated.

Lab tests confirm this (rest of this presentation).

If strip width remains at nominal 25 cm, can reduce number of readout channels by factor of 4.

(Or, can increase position resolution by factor of 4 if keep channel count the same.)

Page 6: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

6Apr. 28, 2007

Test setup

IHEP single gap RPC chamber

Readout strip

Rigid honeycomb panel (1/2” thick)

Al sheet underneath of the honeycomb as ground shielding and strip signal return plane.

Al foil to shield the 8m long strip plane.

Page 7: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

7Apr. 28, 2007

Flexible readout strip band

This is Belle readout strip band, can make large roll of this material.

Page 8: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

8Apr. 28, 2007

Honeycomb panel

½” thick honey comb panel, very rigid, surprisingly its dielectric constant is ~3.80.

Page 9: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

9Apr. 28, 2007

Signal shape

R1=165Ω,R2=38Ω

RPC1 HV ON

R1=165Ω,R2=2Ω

RPC1 HV ON

R1=165Ω,R2=12Ω

RPC1 HV ON

Terminator’s effect on the signal’s shape

Page 10: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

10Apr. 28, 2007

Test TDC and ADC simultaneously

Use CAMAC TDC and charge sensitive ADC modules to test the 8m long strip readout signal.

Page 11: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

11Apr. 28, 2007

Meantimer Time spectrum

The trigger counters are 1m long, therefore the TDC start signal has intrinsic time jitter. We use LeCroy Meantimer modules to eliminate this jitter. Two trigger counters are overlapped, their outputs enter the LeCroy meantimer, its output signal corresponds to the signal initiated at the middle of the counter.

10ns/division

Input #1 of the meantimer

Input #2 of the meantimer

Triggered by output of the meantimer

Page 12: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

12Apr. 28, 2007

Trigger counters at far end of the strip plane

First we place the trigger counters at the far end of the readout strip plane. Near and far end trigger arrangements are shown below:

Page 13: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

13Apr. 28, 2007

Screen capture of the strip signal

80ns/div

50mV/div

The screen captures on the left show several sequentially captured trigger events w/o any other selection.

Page 14: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

14Apr. 28, 2007

TDC and QDC spectrum

We used a LeCroy TDC module and a Phillips QDC module to measure the time and charge spectrum of the full size RPC chamber.

Put the trigger counters at the far end of the strip plane.

The time jitter for a 1m long section of RPC is ~6.5ns

Page 15: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

15Apr. 28, 2007

Trigger counters at near end of the strip plane

Screen captures of strip signal for trigger counters at the near end.

Page 16: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

16Apr. 28, 2007

TDC and QDC spectrum

(1 ch = 0.125pC)

Page 17: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

17Apr. 28, 2007

Peak sensing ADC module test results

0

50

100

150

200

250

0 500 1000 1500 2000

TDC(ch)

TDC, 7400VMean=1041 chSigma=155 ch

0

50

100

150

200

0 500 1000 1500 2000

TDC, 7600VMean=971chSigma=110ch

0

50

100

150

200

250

300

350

0 500 1000 1500 2000

TDC, 7800Vt=928chs=96.5ch

Change HV setting, keep other electronics system fixed, we can see that ADC peak is shifting towards right, and TDC peak is shifting towards left while raising HV from 7400V to 7800V.

ADC calibration:

PH(mV)=(ADC(mV)+31)/0.7

Page 18: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

18Apr. 28, 2007

Correlation between ADC and TDC

0

500

1000

1500

2000

2500

0 500 1000 1500 2000

ADC

TDC

7800V

0

500

1000

1500

2000

2500

0 500 1000 1500 2000 2500

ADC

TDC

7400V

Plot the scatter plot of ADC vs TDC, we found that TDC is quite constant. It does not depend on the ADC reading:

0

500

1000

1500

2000

2500

0 500 1000 1500 2000 2500

ADC

TDC

7600V

Page 19: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands

19Apr. 28, 2007

OPERA RPC system uses 8m long readout strip plane, the following pages show few steps of their installation procedure and the dimension of their strip plane.

Page 20: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands
Page 21: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands
Page 22: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands
Page 23: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands
Page 24: 1 Apr. 28, 2007 Test of the Pulse Height and Time Jitter for the IHEP Full-Size RPC’s with 8-m-Long Readout Strip Planes C. Lu, K. McDonald and W. Sands