1
For additional paper copies or comments E-mail: [email protected]. PDF Downloads available at www.offshore-mag.com. Electronic Data Available. 2010 SURVEY OF OFFSHORE NON-CHEMICAL FLOW ASSURANCE SOLUTIONS Products & Systems Methodologies Poster Compiled By: C-Ray Media, Inc. Poster Graphics by Chris Jones of Xenon Group – www.xenongroupdesign.com APRIL 2010 1455 West Loop South, Suite 400; Houston, TX 77027 Tel: 713-621-9720; Fax: 713-963-6296 www.offshore-mag.com McDermott Subsea Engineering 757 N. Eldridge Pkwy; Houston, Texas 77079 Tel: (281) 870-5000; Fax: (281) 870-5520/5210/5807 E-Mail: [email protected] Website: www.jraymcdermott.com 4 9 23 24 34 40 41 42 59 62 Information Accuracy: Every attempt has been made to locate all companies, their products and services, which provide non-chemical flow assurance solutions. No company was intentionally excluded from the survey. We make no guarantee that this list is all inclusive. We have been careful to summarize the characteristics and experience of each company as well as possible, by acting as a neutral party and integrator of information. We have collected information from each company, phone interviews and personal interviews. Neither McDermott Subsea Engineering nor Offshore Magazine guarantees or assumes any responsibility or liability for any reliance on the information presented. POSTER 84 ©2010 Offshore F: Flowline R: Riser W: Well T: Tree JPR: Jumper JT: Joint M: Manifold HT/HP: High Pressure / High Temperature PL: Pipeline OD: Outer Diameter PIP: Pipe-in-Pipe CAPEX: Capital Expenditure OPEX: Operating Expenditure INSTEX: Installation Expenditure FIELD PROVEN: Previously Used in Field PROTOTYPE: Passed Onshore Test Program CONCEPTUAL: Design Only U-VALUE: Overall Heat Transfer Coefficient Length: 1 in. = 25.4 mm 1 ft. = 0.305 m 1 mile = 1,609 m Thermal Conductivity: 1 Btu/(hr-ft-°F) = 1.73 W/(m-K) U-Value: 1 Btu/(hr-ft 2 -°F) = 5.67 W/(m 2 -K) NOTES: A. Specific heat and density of materials are not provided. These characteristics have a strong influence on cool down time. B. Although extremely important to flow assurance, pigging issues have not been included in these calculations. ABBREVIATIONS: CONVERSION FACTORS: 19 30 31 32 56 57 58 63 64 65 66 67 68 69 61 60 R M A G A Z I N E PHOTO NUMBER WAX HYDRATES SLUGGING DETECTION EMULSION / FOAMING / SCALE REMEDIATION ELECTRICAL HEATING HOT FLUIDS CIRCULATION EXOTHERMIC PROCESSES LINED PIPE (INTERNAL) COILED TUBING REMEDIATION BUNDLED FLOWLINES TFL (THROUGH FLOW LINE) POWER REQUIREMENTS / MILE FLUID TYPE USED (CIRCULATION) FREQUENCY OR CONTINUOUS USAGE INCREASE TEMPERATURE / PRESSURE OFFSET DISTANCE (Mile) BURIED PIPE PIPELINE JACKET INSULATION PIPE-IN-PIPE INSULATION VACUUM INSULATION INSULATED FLEXIBLE PIPE RISER TOWERS INTERNAL INSULATION THERMAL CONDUCTIVITY Btu/(hr-ft-°F) = 1.73W/(m-K) COATING THICKNESS (inch) U-VALUE BASED ON PL OD (RANGE), (Btu/hr-ft2-°F ) UNINSULATED PIPE (COLD FLOW) COLLAPSIBLE PIPE PHASE-CHANGE INSULATION FLOW OPTIMIZED SYSTEM ARCHITECTURE COILED TUBING REMEDIATION INTERNALLY INSULATED CORROSION RESISTANT PIPELINE REDUCES / ELIMINATES CHEMICAL REQUIREMENTS REDUCES / ELIMINIATES ENERGY REQUIREMENTS MINIMIZES CAPEX / INSTEX / OPEX APPLICATION - WELLBORE (W), FLOWLINE (F), RISER (R), JOINTS (JT), JUMPERS (JPR) OFFSET DISTANCE (Mile) PIG MONITORING PRESSURE MONITORING FLOWRATE MONITORING ACOUSTIC - PLUG DETECTION FIBER OPTICS - PLUG DETECTION SAND MONITORING WELDS COLLARS INTEGRATE PRESSURE RATINGS NON INVASIVE CLAMP-ON INVESTIGATED-ENGINEERED-DESIGNED PROTOTYPE TESTED FOR HYDROCARBON USE INSTALLED SUBSEA APPL. INSTALLED SURFACE APPL. TOTAL INSTALLED LENGTH SUBSEA (mile) MAXIMUM WATER DEPTH TESTED (ft) MAXIMUM WATER DEPTH INSTALLED (ft) OIL FIELDS GAS CONDENSATE FIELDS HP / HT FIELDS WELLBORE (W), FLOWLINE (F), RISER (R), JUMPER (JPR), JOINT (JT), MANIFOLD (M), TREE (T) APPLICATION EXPERIENCE CONNECTION METHOD DETECTION SYSTEMS ADVANTAGES OTHER INNOVATIVE METHODS SOLUTION TYPES TYPE CHARACTERISTICS TYPE CHARACTERISTICS TYPE PASSIVE SYSTEMS ACTIVE SYSTEMS ISSUES VENDORS ADVANCED INSULATION SYSTEMS LTD Contact: Kevin Firth, Howard Walker or Philip Watson; 11490 Westheimer Rd #850, Houston, TX 77077; Phone: +1 713-425-6342, +44 (0)7795 350875, +44(0)7740 579774 or +44 (0)7827 848667; E-Mail: [email protected]; Website: www.aisplc.com ContraTherm C55-750-30 Phenolic Based Pack-In-Place Syntactic Foam Subsea Insulation H H 0.12 0.50-10.00 0.2-1.0 H H H R, JPR, JT H H H H H H 10,000 5,500 H H H F, R, JPR, JT, M, T ContraTherm C55-800-03 Phenolic Based Pack-In-Place Syntactic Foam Subsea Insulation H H 0.11 0.50-10.00 0.2-1.0 H H H R, JPR, JT H H H H H H 10,000 5,500 H H H F, R, JPR, JT, M, T ContraTherm C25-770-01 Syntactic Silicone Subsea Insulation H H 0.11 0.50-10.00 0.2-1.0 H H H R, JPR, JT H H H H H H 10,000 5,500 H H H F, R, JPR, JT, M, T ContraFlame JF120 Lightweight Passive Fire Proof Protection and Insulation System H H 0.03 0.75 0.2-1.0 H H H H R, JPR, JT H H H H H Surface Surface H H H F, R, JPR, JT ContraFlex Jet Fire Rated Flexible Protection Jackets H H H 0.03 0.75 0.2-1.0 H H H H R, JPR, JT H H H H H Surface Surface H H F, R, JPR, JT C.TAG High Visibility, Non Toxic,Anti-fouling Subsea Markers H H F, R, JPR, JT H H 5,000 H H F, R, JPR, JT ASPEN AEROGELS, INC. Contact: Mario Saba - Hydrocarbon Processing; 30 Forbes Rd., Bldg. B, Northborough, MA 01532; Phone: 514-487-8693; Fax:508-691-1200; E-Mail: [email protected]; Website: www.aerogel.com 1 Spaceloft™Subsea Aerogel Pipe-in-Pipe (PIP) Insulation H H H H H H H Minimized H H H H H H H H H 0.01 0.2 - 3.0+ 0.02-0.5 H H H H H H F, R, JT H H H H H H H 155 na 9,000 H H H F, R, JT 2 Pyrogel™XT Aerogel Hi Temperature Insulation H H H H H H H H H H H H H H 0.01 0.1 - 10.0+ 0.02-0.5 H H H H H H F, R, JT H H H H H H H H na 9,000 H H H F, R, JT 3 Cryogel™ Z Aerogel Cryogenic Pipe Insulation H H H H H H H 0.01 0.2 - 10+ 0.02-0.5 H H H H H H F, R, JT H H H H H H na na BREDERO SHAW COMPANY Contact: Michael Pierce - Business Development Manager or Josh Croix - Marketing Manager;3838 N. Sam Houston Pkwy East, Suite 300, Houston, TX 77032; Telephone: 281-886-2326; Fax: 281-886-2350; E-Mail: [email protected]; [email protected]; Website: www.brederoshaw.com 4 3 Layer Polypropylene H H H H 0.13 0.4 3.80 H H F, R H H H H 1,900 6,500 2,400 H H H F, R 5 3 Layer Polyethylene H H H H 0.20 0.4 5.20 H H F, R H H H H 14,500 6,500 2,400 H H H F, R 6 4 Layer Polypropylene Foam H H H H H H 0.10 2.5 0.62 H H F, R H H H H H H 210 2,000 2,000 H H H F, R 4 Layer Polypropylene Solid H H H H H H 0.13 2.5 0.75 H H F, R H H H H H H 210 2,000 2,000 H H H F, R 7 ThermoFlo® - S H H H H H H 0.07 4.0 0.28 H H F, R, JT, JPR H H H H 984 950 H H F, R, JT, JPR, M ThermoFlo® - D1400 H H H H H H 0.09 4.0 0.36 H H F, R, JT, JPR H H H H 170 3,600 3,400 H H F, R, JT, JPR, M ThermoFlo® - D2000 H H H H H H 0.09 4.0 0.37 H H F, R, JT, JPR H H H H 75 5,740 5,600 H H F, R, JT, JPR, M ThermoFlo® - D2800 H H H H H H 0.10 4.0 0.41 H H F, R, JT, JPR H H H H 22 7,874 7,400 H H F, R, JT, JPR, M 8 Thermotite® Polypropylene Foam H H H H According to design H According to design H H H 0.10 4.0 0.42 H H F, R, JT, JPR H H H H H 250 1,300 1,300 H H H F, R, JT, JPR Thermotite® Polypropylene Syntactic H H H H According to design H According to design H H H 0.10 4.0 0.41 H H F, R, JT, JPR H H H H H 40 9,000 7,200 H H H F, R, JT, JPR Thermotite® Polypropylene Syntactic (s35) NEW H H H H According to design H According to design H H H 0.09 4.0 0.39 H H F, R, JT, JPR H H H H H H H F, R, JT, JPR 9 Thermotite® Deep Foam (High Density) H H H H According to design H According to design H H H 0.10 4.0 0.44 H H F, R, JT, JPR H H H H H 35 9,000 7,200 H H H F, R, JT, JPR Thermotite® Deep Foam (Low Density) H H H H According to design H According to design H H H 0.09 4.0 0.36 H H F, R, JT, JPR H H H H 0 7,000 - H H H F, R, JT, JPR 10 Thermotite® Polypropylene Composite System H H H H According to design H According to design H H H According to design 4.0 0.44 H H F, R, JT, JPR H H H H H 15 7,000 7,200 H H H F, R, JT, JPR 11 Thermotite® ULTRA™ Foam NEW H H H According to design H H H 0.07 4.0 0.32 H H H H H H H F, R, JT, JPR Thermotite® ULTRA™ Solid NEW H H H According to design H H H 0.09 4.0 0.37 H H H H H H H H F, R, JT, JPR CABOT NANOGEL® AEROGEL Contacts: Aled Rees, Commercial Director: 157 Concord Rd., Billerica, MA 01821; Tel 978-670-NANO; Fax 978-670-7045. Email: [email protected] Raj Saxena, Sales Manager: 4582 Kingwood Dr. Suite E145, Kingwood, TX 77345; Tel 281-361-2330; Fax 281-361-3119. Email: [email protected]; Website: www.nanogel.com 12 Nanogel® AEROGEL COMPRESSION PACK ™ H H H H H H H H H H H 0.01 0.5 - 8.0 0.02-0.5 H H H F, R, JT H H 10,000 H H H F, R, JT 13 Nanogel® AEROGEL EXPANSION PACK ™ H H H H H H H H H H H 0.01 1.0 - 8.0 0.02-0.5 H H H F, R, JT H H 10,000 H H H F, R, JT 14 Nanogel® AEROGEL THERMAL WRAP ™ H H H H H H H H H H H 0.01 0.1 - 12.0+ 0.02-0.5 H H H F, R, JT H H 10,000 H H H F, R, JT 15 Nanogel® AEROGEL INFILL H H H H H H H H H H H 0.010 0.1 - 12.0+ 0.02-0.5 H H H F, R, JT H H 10,000 H H H F, R, JT CLAMPON, INC. Contact: Jim Boecker - Sales Manager or Sam Barton - Operations Manager; 15720 Park Row, Ste. 300, Houston, TX 77084; Phone: (281) 492-9805; Fax: (281) 492-9810; E-Mail: [email protected]; [email protected]; Website: www.clampon.com 16 DSP Particle Monitor (Sand) H H F, R, JT, JPR, H H H H H H 14,850 8,800 H H H F, R, JT, JPR, M, T 17 DSP Corrosion-Erosion Monitoring H H F, R, JT, JPR, H H H H H H H H F, R, JT, JPR, M, T 18 DSP Pig Detector H H F, R, JT, JPR, H H H H H H 14,850 8,800 H H H F, R, JT, JPR, M, T DSP Leak Detector H H F, R, JT, JPR, H H H H H 14,850 1,320 H H H F, R, JT, JPR, M, T CORUS TUBES Contact: Richard Freeman - Business Development Manager or Derek Bish - Sales and Applications Engineer; P.O. Box 101, Weldon Road, Corby, Northants, UK, NN175UA; Phone: 44-1536-404262; Fax: 44-1536-404095; E-Mail: [email protected]; Website: www.corusenergy.com Pipe-in-Pipe (PIP) - Lightweight Structural System H H H H H 0.012-0.023 0.1-0.25 H H H F, R H H H H 8,200 H H H F, R 19 Pipe-in-Pipe (PIP) - Injected Polyurethane foam H H H H H 0.1-0.25 H H H F, R H H H H H 350 350 H H H F, R Pipe-in-Pipe (PIP) - Nanogel® / Polyurethane Foam Hybrid H H H H H 0.02-0.1 H H H F, R H H H H H H H F, R Hydrotherm™ H H H H 0.06 0.25-0.45 H H H F, R H H H H H 45 4,600 350 H H H F, R CUMING INSULATION CORPORATION Contact: Elmer Hershey or Larry King; 515 N. Sam Houston Parkway, E, #630, Houston, TX 77060; Phone: 281- 591-1069; Fax: 281- 591-0284; E-Mails: [email protected] or [email protected]; Website: www.bayouflow.com www.cumingcorp.com 20 C-THERM S Syntactic Foam Insulation for Flow Lines and Risers H H H H H H H 0.04 - 0.08 1.00 - 4.00 0.20 - 1.0 H H H F, R Various H H H H H H H 5 10,000 5,000 H H H F, R 21 C-THERM P Syntactic Foam for Jumpers, Trees, Manifolds, Etc. H H H H 0.04 - 0.08 1.00 - 4.00 0.20 - 1.0 H H H JPR H H H H H H H 10,000 7,500 H H H T, M, JPR C-THERM F Syntactic Foam Sleeves for Field Joints, Jumpers, Etc. H H H H 0.04 - 0.08 1.00 - 4.00 0.20 - 1.0 H H H JPR, JT H H H H H H H 10,000 7,000 H H H JPR, JT C-THERM R Syntactic Foam Hybrid Riser Buoyancy & Insulation H H H H H 0.04 - 0.08 As Required 0.20 - 1.0 H H H R H H H H H H H 10,000 5,000 H H H R DEEPFLEX Contact: Ramon A. Perez or David Barnes - Directors of Business Development; 3350 Rogerdale, Suite 200, Houston, TX 77042; Phone: 713-334-1500; Fax: 713-334-1506; Email: [email protected]; [email protected];; Website: deepflex.com 22 DeepFlex Flexible Pipe H H 0.08 0.25 - 0.70 H H H F, R, JPR 25 H H H H 3.5 10,000 5,000 H H F, R, JPR DOW HYPERLAST Contact: (USA) - Mike Huspek - Global Account Manager; 901 E. Kankakee River Dr., Wilmington, IL 60481; Phone: +1 815-476-1172; Email: [email protected]. (Europe) Stuart B. Carlyle - Bus. Dev Mgr. Or Rob Ashton - Technology Leader; Station Road, Birch Vale, High Peak, Derbyshire, SK22 1BR, United Kingdom; Phone: 44-1663-748518; Fax: 44-1663-746605; E-mail: [email protected]; Web Site: www.dowhyperlast.com 23 Hyperlast™ Syntactic LD512E H H H H H 0.06 0.5 - 5 >0.25 H H W, F, R, JT, JPR H H 7 1,150 150 H H H F, R, JPR, JT, M, T Hyperlast™ Syntactic 512 H H H H H 0.07 0.5 - 5 >0.3 H H W, F, R, JT, JPR H H H H 450 1,150 1,150 H H H F, R, JPR, JT, M, T Hyperlast™ Syntactic 512E H H H H H 0.07 0.5 - 5 >0.3 H H W, F, R, JT, JPR H H 9 1,150 500 H H H F, R, JPR, JT, M, T Hyperlast™ Syntactic 512R H H H H H 0.07 0.5 - 5 >0.3 H H W, F, R, JT, JPR H H H H 1.4 1,150 500 H H H JT, M Hyperlast™ Syntactic HT512 H H H H H 0.07 0.5 - 5 >0.3 H H W, F, R, JT, JPR H H H H 1,150 H H H F, R, JPR, JT, M, T Hyperlast™ Syntactic DW-512/150 H H H H H 0.08 0.5 - 5 >0.35 H H W, F, R, JT, JPR H H 80 4,500 4,020 H H H F, R, JPR, JT, M Hyperlast™ Syntactic DW-512/150E H H H H H 0.08 0.5 - 5 >0.35 H H W, F, R, JT, JPR H H 73 4,500 3,915 H H H F, R, JPR, JT, M Hyperlast™ Syntactic DW-512/200E H H H H H 0.09 0.5 - 5 >0.35 H H W, F, R, JT, JPR H H 103 6,600 5,030 H H H F, R, JPR, JT, M Hyperlast™ Syntactic DW-512/300 H H H H H 0.1 0.5 - 5 >0.35 H H W, F, R, JT, JPR H H H 200 10,000 7,645 H H H F, R, JPR, JT, M Hyperlast™ Syntactic DW-512/300E H H H H H 0.1 0.5 - 5 >0.35 H H W, F, R, JT, JPR H H 5 10,000 6,860 H H H F, R, JPR, JT, M Hyperlast™ FJ589 H H H H H 0.11 0.5 - 5 >0.45 H H W, F, R, JT, JPR H H H 10,000 6,200 H H H F, JPR, JT, M Hyperlast™ FJ902 H H H H H 0.11 0.5 - 5 >0.45 H H W, F, R, JT, JPR H 10,000 H H H F, JPR, JT, M Hyperlast™ FJ125 H H H H H 0.11 0.5 - 5 >0.45 H H W, F, R, JT, JPR H 10,000 1,550 H H H F, JPR, JT, M Hyperlast™ FJ302 H H H H H 0.11 0.5 - 5 >0.45 H H W, F, R, JT, JPR H H H 10,000 H H H F, JPR, JT, M Hyperlast™ FJ303 H H H H H 0.11 0.5 - 5 >0.45 H H W, F, R, JT, JPR H H H 10,000 4,885 H H H F, JPR, JT, M Hyperlast™ FJ439E H H H H H 0.11 0.5 - 5 >0.45 H H W, F, R, JT, JPR H 10,000 H H H F, JPR, JT, M Hyperlast™ FJ548E H H H H H 0.11 0.5 - 5 >0.45 H H W, F, R, JT, JPR H H H 10,000 H H H F, JPR, JT, M Hyperlast™ FJ689E H H H H H 0.11 0.5 - 5 >0.45 H H W, F, R, JT, JPR H 10,000 H H H F, JPR, JT, M Hyperlast™ FJF Rigid PU Foam for Field Joint H H H H 0.05 - 0.2 H H H F, R, JT, JPR H H H H H H H H F, R, JPR, JT, M Hyperlast™ PUF Rigid PU Foam for flowline insulation H H H H H 0.01 0.5 - 6 <0.033 H H H F, R H H H H H H H H F, R, JPR, JT, M DYNA MONITORING CORPORATION Contact: Glen Sumner - 8306 Leafy Lane, Houston, Texas 77055; Phone 713-973-7285; Fax 713-973-7286; E-mail: [email protected] 24 Aqua Therm Submersible Insulation - (solid, very cost effective) H H H H H H H 0.1 >1 0.2 - 1.3 H H H 1 to 25 H H 8,000 2,100 H H H F, R, JT, JPR, M, T 25 Hysulate Submersible Insulation (400 degree operating temperature) H H H H H 0.02 >0.25 0.37 - 8 H H H H H 4,500 1,500 H H H W, F, R, JT, JPR,M, T Proprietary electric flowline heating (return cable optional) H H H H as needed C Y 0-25 H H H H H 1 to 25 H H 4,500 H H H F, R, JT, JPR FMC TECHNOLOGIES Contact: Eric Heuring - Global Thermal Insulation Manager or Michael Coles - Technical Manager; 1777 Gears Rd., Houston, TX 77067; Phone 281-591-4578; Fax: 281-405-4937-Mail: [email protected]; Website: www.fmctechnologies.com Novotherm™ H H 0.1 1.0 - 3.0 0.35 - 0.12 H R,JT,JPR H H H H H 10,000 7,000 H H JPR, JT, M, T 26 Novolastic™ HT H H 0.1 1.0 - 3.0 0.35 - 0.12 H R,JT,JPR H H H H H 10,000 9,350 H H JPR, JT, M, T Heat Tracing for Subsea Hardware 10-30 kW 1.0 - 3.0 0.35 - 0.12 H H H H H H JPR, M, T FOSTER WHEELER OPE UPSTREAM Contact: Richard Gaona - Marketing Manager; 585 North Dairy Ashford, Houston, TX 77079; Phone: 713-929-5000; Fax: 713-929-5188; E-Mail: [email protected]; Website: www.opeinc.com Single Insulated Pipeline and Riser H H H H H H H H H H H 0.85 0.5 - 5 >0.35 H H H H F, R, JT, JPR H H H H H H H H 10,000 9,000 H H H F, R, JT, M Syntactic Foam for Jumpers, Trees, Manifolds, Etc. H H H H H 0.85 0.5 - 5 >0.35 H H H H F, R, JT, JPR H H H H H H H H 10,000 9,000 H H H JPR,M,T Pipe-in-Pipe Pipeline and Riser H H H H H H H H H H H 0.01 0.25 - 3.0 0.02-0.5 H H H H F, JT H H H H H H H H 10,000 8,000 H H H F, JT LPG Cryogenic Pipeline H 0.02 1.1 0.2 H H F, JT H H H 0.15 115 H H F, JT, M LNG Cryogenic Pipeline H H 0 1 0.03 H H H F, JT H H H H F, JT, M ITP INTERPIPE Contact: (USA) - Vicki Niesen;16360 Park Ten Place, Suite 327, Houston, TX 77084; Phone: 281-492-2576: E-Mail: [email protected]. (Europe) - Wayne Grobbelaar; 11 Quai Conti, 78430 Louveciennes, France; Phone: (+33) 180 108 091; [email protected]; Website: www.itp-interpipe.com 27 Highly Insulated Double Wall Pipe H H H H 0.0030 - 0.01 0.2-1 0.05 - 0.4 H H H F,R 60 H H H H 160 10,000 4800 H H H F, R, J 28 Light Weight Double Wall Pipe H H H H 0.0030 <1 0.05 - 0.4 H H H F,R 60 H H H 10,000 H H H F, R 29 Ultimate Pipe H H H 0.010 <1 0.15 - 0.4 H H H F,R 40 H H H 10,000 H H F, R, J 30 McPipe (10 Days Cooldown) Developed w/ J. Ray McDermott, Inc. H H H H 0.0030 1-2 0.05 - 0.3 H H H H F,R 60 H H H 10,000 H H F, R, J 31 Heat Traced Pipe H H H 8 - 20 kW H H 0.0030 <1 0.05 - 0.25 H H H F,R 60 H H H 6,500 H H F, R, J 32 LPG Refrigerated Pipe H 0.0030 1-2 0.01 - 0.1 H H F,R 15 H H H H H 4 50 50 F, R 33 LNG Cryogenic Pipe H 0.0025 2 0.01 - 0.03 H H F,R 15 H H H 50 F, R NEXANS NORWAY Contact: Marc Joyce - VP Business Development; 16420 Park Ten Place, Suite 580, Houston, TX 77084; Phone: 281-578-6900; Fax: 281-578-6991; E-Mail: [email protected]; Website: www.nortech.com or Bjorn Bjornstad, Innspurten 9, PO Box 6450, 0605 Oslo, Norway; Phone: 4722886100; Fax: 4722886378; E-Mail: [email protected]; Website: www.nexans.com 34 DEH H H H H H H H H 0.1 .52 - 1.76 H H H H H 140 2,790 1200 H H H F, JT, R PERMA-PIPE OIL & GAS Contact: Hank C. Reuser - Vice President or Chris Weierman - Technical Sales Engineer; 515 N. Sam Houston Parkway E, #630, Houston, TX 77060; Phone: 281- 598-6222; Fax: 281- 591-0284; E-Mails: [email protected] & [email protected]; Website: www.permapipe.com 35 AUTO-THERM Glass Syntactic Polyurethane (GSPU) for Flowlines & Jumpers H H H H H H H 0.07 0.50 - 4.00 0.4 - 2.0 H H H H F, R, JT, JPR H H H H H > 100 miles 10,000 10,000 H H H F, R, JT,JPR 36 AUTO-THERM Glass Syntactic Polyurethane for Subsea Equipment H H 0.08 0.50 - 4.00 0.4 - 2.0 H H H F, R, JT, JPR H H H H H 10,000 4,000 H H H F, R, JT,JPR, M, T 37 XTRU-THERM Mid to High Density Wet Insulation PU with PE Jacket H H H H H H H H 0.02 0.75 - 5.00 0.15 H H H F, R, JT, JPR H H H H H 36 miles 650 575 H H H F, R, JT 38 XTRU-THERM Pipe-in-Pipe (PIP) Polyurethane Foam with PE Jacket H H H H H H H 0.02 0.75 - 4.00 0.1 H H H F, R, JT H H H H H 250 miles 10,000 7500 H H H F, R, JT 39 XTRU-THERM Cryogenic Pipeline -Mid Density PU Foam with PE Jacket H H 0.01 0.75 - 6.00 0.03 H H H H H H H 2 miles H F, JT ROXAR Contact: Chris McPherson; 3300 Walnut Bend Lane, Houston, TX 77042; Phone: 713-334-2222; E-Mail: Chris. [email protected]; Website: www.roxar.com 40 Sand and Erosion Monitoring System H W, F, R, JT, JPR H H H H H 10,000 7,800 H H H W, F, R, JT,T 41 FSM™ Corrosion / Erosion Monitoring System H H H H H H W, F, R, JT, JPR H H H H 10,000 6,500 H H H F, R, JT 42 Pressure / Temperature Monitoring H H H W, F, R, JT, JPR H H H H H H 10,000 7,800 H H H W, F, R, JT, M,T Flow Force H H H W, F, R, JT, JPR H H H H H 10,000 1,000 H H H W, F, R, JT, M,T 43 Roxar Subsea MPFM H H H W, F, R, JT, JPR H H H H H H H H 10,000 9,000 H H H W, F, R, JT, M,T 44 Roxar Subsea Sand monitor/ Pig detector H H F, R, JT, JPR H H H H H H H 9,842 9,600 H H H F, R, JT, JPR, M, T SAIPEM Contact: Luc Poirson, Saibos SAS; rue Stephenson, 78 884 St. Quentin en Yvelines Cedex, France; Phone: 33-161-37-6661; e-mail: [email protected]; Loic Delebecque, Saipem SA; Bat. Energies, TEDE 1/7 avenue San Fernando, 78884 St. Quentin en Yvelines, France; Phone: 33-161-37-7286; Fax: 33-161-37-8380; e-mail: [email protected] 45 Bundle Hybrid Offset Riser (BHOR) - Riser Tower H H H H H 0,007 - 0,07 0.25 - 2.0 0.16 H H H R H H H H H 2.5 10,000 4,000 H H H R Pipe in Pipe Single Hybrid Riser (PiP SHR) H H H 0,1 - 0,13 1-5 0.36 H H H R H H H H 2 10,000 3,400 H H H R PU foam insulated Pipe in Pipe (PUF PiP) H H H 0,012-0,024 0,5 - 6 0.18 H H H F, R H H H H 24 10,000 3,400 H H H F, R 46 Aerogel insulated Pipe in Pipe H H H 0.01 0,25-2,0 0.16 H H H F, R H H H H 6 10,000 4,200 H H H F, R Vactub® - Vacuum insulated Pipe in Pipe H H H H 0 1 0.09 H H H F, R H H H 10,000 H H H F, R Gel insulating material H H H 0.08 H H H F, R, JPR, JT H H 10,000 H H F, R, JPR, JT 47 Gel ILS - Phase change insulating material H H H 0.11 H H H H F, R, JPR, JT H H 10,000 H H F, R, JPR, JT Gel / Gel ILS production Flowline H H H 0,084-0,11 1-6 0.32 H H H H F, R H H H 10,000 H H F, R 48 Gel production Bundle H H H 0.08 1-8 0,14-0,28 H H H F H H H 10,000 H H F Single Pipe Flowline & Riser H H H 0.1-0.13 4 0.47 H H H F, R, JPR H H H H 33 10,000 4,600 H H F, R, JPR SOCOTHERM AMERICAS Contact: Cristian Grecco; Ruta 9, km 52.3 Escobar, Buenos Aires, Argentina (1625); Phone: +54.3488.433.500; e-mail: [email protected]; Website: www.socotherm.com.ar 49 Plastykote® Three Layer Polyethylene H H H 0.13 0.06 - 0.5 > 1.90 H H H F, R, JT, JPR H H H H H H 35,000 10,000 8,200 H H H F, R, JT, JPR 50 Plastykote® Three Layer Polypropylene H H H 0.2 0.06 - 0.5 > 1.90 H H H F, R, JT, JPR H H H H H H 5,000 10,000 8,200 H H H F, R, JT, JPR 51 Wetisokote® Five Layer Solid Polypropylene H H H Acc. to design H H H 0.13 0.5 - 6.0+ > 0.40 H H F, R, JT, JPR H H H H H H 60 10,000 6,600 H H H F, R, JT, JPR 52 Wetisokote® Five Layer Polypropylene Foam H H H Acc. to design H H H 0.095 - 0.101 0.5 - 6.0+ > 0.35 H H F, R, JT, JPR H H H H H H 104 2,000 1,800 H H H F, R, JT, JPR 53 Wetisokote® Five Layer Syntactic Polypropylene H H H Acc. to design H H H 0.081 - 0.092 0.5 - 6.0+ > 0.35 H H F, R, JT, JPR H H H H H H 165 10,000 8,200 H H H F, R, JT, JPR 54 Thermakote® High Density Polyurethane Foam H H H Acc. to design H H H 0,02 - 0,03 1,0 - 4,0 > 0.10 H H F, R, JT, JPR H H H H H H 60 650 330 H H H F, R, JT, JPR 55 Pipe in Pipe H H H Acc. to design H H H > 0.018 Annular Gap 0.10 - 0.36 H H F H 100 10,000 5,000 H H H F SOCOTHERM LABARGE Contact: Hermann Buschor, Fernando Ulecia; 817 Shields Street Channelview, TX 77530, USA; Phone: +1713.378.7200; e-mail: [email protected]; [email protected]; Website: www.socothermlabarge.com 49 Plastykote® Three Layer Polyethylene H H H 0.13 0.06 - 0.5 > 1.90 H H H F, R, JT, JPR H H H H H H 35,000 10,000 8,200 H H H F, R, JT, JPR 50 Plastykote® Three Layer Polypropylene H H H 0.2 0.06 - 0.5 > 1.90 H H H F, R, JT, JPR H H H H H H 5,000 10,000 8,200 H H H F, R, JT, JPR 51 Wetisokote® Five Layer Solid Polypropylene H H H Acc. to design H H H 0.13 0.5 - 6.0+ > 0.40 H H F, R, JT, JPR H H H H H H 60 10,000 6,600 H H H F, R, JT, JPR 52 Wetisokote® Five Layer Polypropylene Foam H H H Acc. to design H H H 0.095 - 0.101 0.5 - 6.0+ > 0.35 H H F, R, JT, JPR H H H H H H 104 2,000 1,800 H H H F, R, JT, JPR 53 Wetisokote® Five Layer Syntactic Polypropylene H H H Acc. to design H H H 0.081 - 0.092 0.5 - 6.0+ > 0.35 H H F, R, JT, JPR H H H H H H 165 10,000 8,200 H H H F, R, JT, JPR 54 Thermakote® High Density Polyurethane Foam H H H Acc. to design H H H 0,02 - 0,03 1,0 - 4,0 > 0.10 H H F, R, JT, JPR H H H H H H 60 650 330 H H H F, R, JT, JPR TECHNIP Contact: Yogesh Kapoor or Juan Manzano - Account Managers, 11700 Katy Freeway, Suite 150 - Houston, TX 77079; Phone: 281-870-1111; Fax: 281-249-7646; Email: [email protected] or [email protected]; Website: www.technip.com Multi-Pass Plough / Back-Fill Plough H H H 0.6 - 1.5 F H H H H H 1,250 1,640 1,020 H H H F Flexjet 1 Trencher H H H 0.6 - 1.5 F H H H H H >450 1,640 1,150 H H H F TM9 Trencher H H H 0.6 - 1.5 F H H 197 1,000 660 H H H F Single Pipe Flowline & Riser H H H 0.04 - 0.17 0.0 - 4.0 >0.5 F, R, JPR H H H H H H H 2,150 10,000 4,510 H H H F, R, JPR Pipe-in-Pipe Flowline & Riser H H H 0.007 - 0.02 0.0 - 0.5 >0.09 H H H F, R, JPR H H H H H H H 10,000 6,900 H H H F, R, JPR Electrically Heated Pipe-in-Pipe Flowline & Riser H H H H 24 - 240kW H H H H H 0.007 - 0.02 0.0 - 0.6 >0.1 H H F, R, JPR H H H H H H H 10,000 H H H F, R, JPR Plastically Lined Pipeline for Water Injection Service H H H 0.04 - 0.17 0.0 - 4.0 >0.5 H H F, R H H H H H H 10,000 H H H F, R Plastically Lined Pipeline for Hydrocarbon Transport H H H H H 0.04 - 0.17 0.0 - 4.0 >0.5 H H F, R H H H H H 10,000 H H H F, R Integrated Production Bundle H H H H H H H F, R, JPR H H H H 10,000 H H H F, R, JPR NG Cryogenic Pipe-in-Pipe H 0.01 2.3 - 3.1 0.016 - 0.022 H H H H H 50 F, R LNG Cryogenic Flexible Hose H H H H H H JPR TRELLEBORG OFFSHORE (Incorporating Trelleborg Offshore US Inc., Trelleborg Offshore UK Ltd., Trelleborg Offshore Norway A.S) Contact: (USA) - Jim Haslam - Sales Manager - Thermal Insulation. Trelleborg Offshore US, Inc. 519 N Sam Houston Pkwy E, Suite 200 Houston, TX 77060 Direct: +8324568358 Mobile: +2817434031 E-Mail: [email protected]. (Europe) Ben Wait - Sales Manager - Thermal Insulation, Trelleborg Offhshore UK Ltd. Paxton Place, West Pimbo, Skelmersdale, Lancashire WN8 9QH, UK, Phone +44 (0) 1695 714332, Fax: +44 (0)1695 555586; E-Mail: [email protected], Website: www.trelleborg.com/offshore. 56 ARDENT™ - (High Temperature Phenoilc Syntactic) H H H H H 0.18 0.5-6.0 >0.29 H H H R, JT, JPR H H H H H H 9,800 H H H F, R, JT, JPR, M, T 57 URATHERM™ - S250 (Syntactic Polyurethane) H H H H H 0.06 0.5-6.0 >0.18 H H H F, R, JT, JPR H H H H H >50(B) 720 720 H H H F, R, JT, JPR, M, T 58 URATHERM™ - G3000 (Syntactic Polyurethane) H H H H H 0.1 0.5-6.0 >0.28 H H H F, R, JT, JPR H H H H H >2200(B) 6,560 6,560 H H H F, R, JT, JPR, M, T 59 URATHERM™ - G3000HT (Syntactic Polyurethane) H H H H H 0.09 0.5-6.0 >0.27 H H H F, R, JT, JPR H H H H H 7,320 H H H F, R, JT, JPR, M, T 60 URATHERM™ - P7000 (Polyurethane) H H H H H 0.11 0.5-6.0 >0.32 H H H F, R, JT, JPR H H H H H >25 23,000 23,000 H H H F, R, JT, JPR, M, T URATHERM™ - PIP (Foamed Polyurethane for Pipe In Pipe systems) H H H 0.01 0.5-6.0 >0.033 H H H F, R H H H H >20 N/A N/A H H H F, R 61 ULTRATHERM™ - 1500 (Syntactic Foam) H H H H H 0.06 0.5-6.0 >0.16 H H H F, R, JT, JPR H H H H H >200(B) 6,560 5,085 H H H F, R, JT, JPR, M, T 62 ULTRATHERM™ - 2000 (Syntactic Foam) H H H H H 0.07 0.5-6.0 >0.19 H H H F, R, JT, JPR H H H H H 8,200 4,265 H H H F, R, JT, JPR, M, T ECCOTHERM® 7000 H H H H 0.07 0.5-6.0 >0.23 H H H F, R, JT, JPR H H H H H >1 23,000 23,000 H H H F, R, JT, JPR, M, T 63 ECCOTHERM® PT 1000 H H H H 0.09 0.138 per layer >1 H H H F, R H H H H H >50 1,000 H H H F, R 64 ECCOTHERM® PT 3000 H H H H 0.09 0.138 per layer >1 H H H F, R H H H H H >50 3,000 2,000 H H H F, R ECCOTHERM® PT 7000C Blue H H H H 0.1 0.138 per layer >1 H H H F, R H H H H H >100 7,000 4,000 H H H F, R 65 THERMOGEL™ 3000 H H H H 0.07 Gel >0.2 H H H W, JT H H H H 9,800 700 H H H F, R, JT, JPR 66 VIKOTHERM - HISC protection H H H H H H H 0.075 0.15 - 6.0 >0.3 H H H W, R, JT, JPR H H H H H H H >10 6,560 5,000 H H H W,F,R,JPR,JT,M,T 67 VIKOTHERM - High temp resistant H H H H H H H 0.075 0.15 - 6.0 >0.3 H H H W, R, JT, JPR H H H H H H H >10 6,560 5,000 H H H W,F,R,JPR,JT,M,T 68 VIKOTHERM - Standard H H H H H H H 0.075 0.15 - 6.0 >0.3 H H H W, R, JT, JPR H H H H H H H >10 6,560 5,000 H H H W,F,R,JPR,JT,M,T WELLSTREAM INTERNATIONAL, LTD.Contact: Tricia Hill - VP, Business Development North America; 11210 Equity Drive, Suite 350, Houston, TX 77041; Phone: 281-249-0925; Fax: 713-431-0884; E-Mail: [email protected]; (2)Contact: Shawn Goertz - Technical Sales; Phone: 281-249-0936; Email: [email protected]; Website: www.wellstream.com 69 Wellstream Flexible Pipe H H H H 0.08 0.25 - 0.70 H H H F, R, JPR 15.5 H H H H 600 10,000 6,500 H H H F, R, JPR WATER DEPTH (ft) 4,000' 0' 2,000' 1,000' 3.000' 5.000' 6,000' 7,000' 8,000' 9,000' 10,000' 5,500 10,000 10,000 7,500 4,000 10,000 10,000 4,500 10,000 8,000 2,100 10,000 10,000 7,200 10,000 CONCEPTUAL PROTOTYPE FIELD PROVEN 9,000 unlimited 5,000 5,000 10,000 10,000 7,000 10,000 2,400 6,500 10,000 2,400 6,500 2,000 8,500 7,400 1,150 7,200 9,000 7,000 7,200 10,000 10,000 10,000 10,000 10,000+ 8,800 10,000+ 8,800 10,000+ 10,000+ 1,320 10,000 350 10,000 4,600 350 10,000 8,200 10,000 1,150 500 10,000 10,000 6,600 5,030 10,000 7,645 10,000 6,860 10,000 6,200 10,000 1,550 10,000 4,885 4,500 1,500 10,000 7,000 10,000 9,000 4,800 10,000 6,500 10,000 10,000 2,790 1,200 10,000 7,800 10,000 6,500 10,000 7,800 10,000 9,000 9,600 1,000 10,000 3,400 10,000 4,200 10,000 4,200 10,000 10,000 9,000 10,000 6,600 10,000 10,000 8,200 10,000 6,500 9,840 720 7,320 6,560 10,000+ 8,200 4,265 1,000 3,000 2,000 7,000 4,000 9,840 700 6,560 5,000 1,000 660 10,000 4,510 1,150 1,640 1,640 1,020 100 (Btu/hr.ft 2 .°F) - 567 W/m 2 .K 50 (Btu/hr.ft 2 .°F) - 284 W/m 2 .K 10 (Btu/hr.ft 2 .°F) - 57 W/m 2 .K 5 (Btu/hr.ft 2 .°F) - 28 W/m 2 .K 0.5 (Btu/hr.ft 2 .°F) - 2.8 W/m 2 .K 0.05 (Btu/hr.ft 2 .°F) - 0.3 W/m 2 .K 1 (Btu/hr.ft 2 .°F) - 5.7 W/m 2 .K 0.1 (Btu/hr.ft 2 .°F) - 0.6 W/m 2 .K 0.01 (Btu/hr.ft 2 .°F) - 0.06 W/m 2 .K U-VALUE (Btu/hr-ft 2 -°F) Based on PL OD 1.9 <0.033 0.05 - 0.2 3.8 0.6 0.20 0.20 0.02 0.02 0.02 0.02 0.02 >0.25 >0.30 >0.35 >0.35 >0.35 >0.35 >0.45 >0.45 >0.45 >0.45 >0.45 >0.45 >0.45 >0.45 1.3 - 0.2 0.16 0.36 0.18 0.16 0.09 0.32 0.47 Material used in sealed pipe in pipe systems (PIP) - not water depth dependant in this application >0.5 >0.1 >0.05 >0.09 >0.26 >0.26 >0.26 >0.2 >0.1 >0.1 >0.1 >0.23 >0.19 >0.16 >0.033 >0.28 >0.18 >0.29 8,200 10,000 10,000 10,000 10,000 10,000 10,000 4,600 9,200 1,150 4,200 5,900 5,600 2,000 6,000 5,000 5,000 10,000 5,000 10,000 1,150 1,150 1,150 10,000 10,000 10,000 10,000 4,020 4,500 3,915 4,500 10,000 8,000 10,000 8,000 10,000 9,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 7,500 4,000 10,000 3,400 10,000 10,000 9,000 10,000 9,000 10,000 9,000 4,600 10,000 10,000 8,200 2,000 1,800 10,000 8,200 5,000 10,000 10,000 6,600 10,000 8,200 10,000 8,200 2,000 1,800 10,000 8,200 10,000 6,900 10,000 10,000 10,000 6,560 5,000 6,560 5,000 10,000+ 6,560 5,085 0.20 0.20 0.20 0.02 0.02 5.3 0.75 0.28 0.36 0.37 0.41 0.42 0.41 0.39 0.44 0.36 0.32 0.37 0.44 0.05-0.25 0.1-0.25 0.02-0.2 0.25-0.5 0.20 0.20 0.20 0.20 0.25 >0.35 >0.30 >0.30 >0.30 8 - 0.37 0.35-0.12 0.35-0.12 0.35-0.12 >0.35 >0.35 0.02 0.2 0.029 0.4 - 0.05 0.4 - 0.05 0.4- 0.15 0.3 - 0.05 0.25 - 0.05 0.1 - 0.01 0.03-0.01 1.76 - 0.52 0.5 0.5 0.15 0.10 0.03 0.18 1.9 1.9 - 0.40 1.9 - 0.35 1.9 - 0.35 0.70 - 0.10 0.36 - 0.10 1.9 1.9 1.9 - 0.40 1.9 - 0.35 1.9 - 0.35 0.70 - 0.10 >0.27 >0.32 0.25 2 3 5 6 7 8 49 50 51 52 53 54 55 1 10 11 12 13 14 15 16 17 18 20 21 22 25 26 27 28 29 33 35 36 37 38 39 43 44 45 46 47 48 Engineering Polymer Excellence A Pipeline Flow Assurance Partner Dow Hyperlast’s professionals work with industry leaders and applicators to specify, support, and service systems that ensure pipeline performance throughout the life of the line. www.dowflowassurance.com cabot-corp.com/aerogel.com UNSURPASSED THERMAL PERFORMANCE UNRIVALED TECHNICAL EXPERTISE UNMATCHED VERSATILITY OF PRODUCT FORM Oceans cover 285 billion barrels of the world’s known oil reserves – OFFSHORE covers them all. M A G A Z I N E World Trends and Technology for Offshore Oil and Gas Operations 2010 PETROLEUM EVENTS CALENDAR Oil Sands and Heavy Oil Technologies Conference & Exhibition July 20 – 22, 2010 | Calgary, Alberta, Canada www.oilsandstechnologies.com World Energy Congress Sept. 12 – 16, 2010 | Montréal, Quebec, Canada www.wecmontreal2010.ca Offshore Middle East Conference & Exhibition Oct. 12 – 14, 2010 | Doha, Qatar www.offshoremiddleeast.com Deep Offshore Technology International Conference & Exhibition – Amsterdam Nov. 30 – Dec. 2, 2010 | Amsterdam, Netherlands www.deepoffshoretechnology.com Oil & Gas Maintenance Technology North America Conference & Exhibition Aug. 31 – Sept. 2, 2010 | New Orleans, Louisiana USA www.ogmtna.com Unconventional Gas International Conference & Exhibition Oct. 5 – 7, 2010 | Ft. Worth, Texas USA www.unconventionalgas.net Deepwater Operations Forum & Exhibition Nov. 2 – 4, 2010 | Galveston, Texas USA www.deepwateroperations.com Protecting the pipelines that bring energy to the world Hermann Buschor [email protected] Fernando Ulecia [email protected] www.SocothermLaBarge.com Socotherm LaBarge LLC 817 Shields Street Channelview, Texas 77530 Toll Free 866.992.4191 Insulation and Coatings Technology for Deepwater Pipelines, Flowlines, and Risers For a hot product in a cold environment... We keep you insulated Phone: 713.378.7200 | Fax: 713.378.7299 Contact:

0410OS_FlowPoster

Embed Size (px)

Citation preview

Page 1: 0410OS_FlowPoster

For additional paper copies or comments E-mail: [email protected]. PDF Downloads available at www.offshore-mag.com. Electronic Data Available.

2010 SURVEY OF OFFSHORE NON-CHEMICAL

FLOW ASSURANCE SOLUTIONSProducts & Systems Methodologies

Poster Compiled By: C-Ray Media, Inc.Poster Graphics by Chris Jones of Xenon Group – www.xenongroupdesign.com

APRIL 20101455 West Loop South, Suite 400; Houston, TX 77027

Tel: 713-621-9720; Fax: 713-963-6296 www.offshore-mag.com

McDermott Subsea Engineering757 N. Eldridge Pkwy; Houston, Texas 77079

Tel: (281) 870-5000; Fax: (281) 870-5520/5210/5807E-Mail: [email protected]

Website: www.jraymcdermott.com

4

9

23 24

34

40 41 42

59

62

Information Accuracy: Every attempt has been made to locate all companies, their products and services, which provide non-chemical flow assurance solutions. No company was intentionally excluded from the survey. We make no guarantee that this list is all inclusive. We have been careful to summarize the characteristics and experience of each company as well as possible, by acting as a neutral party and integrator of information. We have collected information from each company, phone interviews and personal interviews. Neither McDermott Subsea Engineering nor Offshore Magazine guarantees or assumes any responsibility or liability for any reliance on the information presented.

POSTER

84 ©20

10 O

ffsh

ore

F: Flowline R: Riser W: Well T: Tree JPR: Jumper JT: Joint M: Manifold HT/HP: High Pressure / High Temperature PL: Pipeline OD: Outer Diameter PIP: Pipe-in-Pipe CAPEX: Capital Expenditure OPEX: Operating Expenditure INSTEX: Installation Expenditure FIELD PROVEN: Previously Used in Field PROTOTYPE: Passed Onshore Test Program CONCEPTUAL: Design Only U-VALUE: Overall Heat Transfer Coefficient

Length: 1 in. = 25.4 mm 1 ft. = 0.305 m 1 mile = 1,609 m

Thermal Conductivity: 1 Btu/(hr-ft-°F) = 1.73 W/(m-K)

U-Value: 1 Btu/(hr-ft2-°F) = 5.67 W/(m2-K)

NOTES:A. Specific heat and density of materials are not provided.

These characteristics have a strong influence on cool down time.B. Although extremely important to flow assurance, pigging issues

have not been included in these calculations.

ABBREVIATIONS: CONVERSION FACTORS:

19

30 31 32

56 57 58

63 64 65 66 67 68 69

6160

R

M A G A Z I N E

PHOT

O NU

MBE

R

WAX

HYDR

ATES

SLUG

GING

DETE

CTIO

N

EMUL

SION

/ FO

AMIN

G / S

CALE

REM

EDIA

TION

ELEC

TRIC

AL H

EATI

NG

HOT

FLUI

DS C

IRCU

LATI

ON

EXOT

HERM

IC P

ROCE

SSES

LINE

D PI

PE (I

NTER

NAL)

COIL

ED T

UBIN

G RE

MED

IATI

ON

BUND

LED

FLOW

LINE

S

TFL

(THR

OUGH

FLO

W L

INE)

POW

ER R

EQUI

REM

ENTS

/ M

ILE

FLUI

D TY

PE U

SED

(CIR

CULA

TION

)

FREQ

UENC

Y OR

CON

TINU

OUS

USAG

E

INCR

EASE

TEM

PERA

TURE

/ PR

ESSU

RE

OFFS

ET D

ISTA

NCE

(Mile

)

BURI

ED P

IPE

PIPE

LINE

JAC

KET

INSU

LATI

ON

PIPE

-IN-P

IPE

INSU

LATI

ON

VACU

UM IN

SULA

TION

INSU

LATE

D FL

EXIB

LE P

IPE

RISE

R TO

WER

S

INTE

RNAL

INSU

LATI

ON

THER

MAL

CON

DUCT

IVIT

Y

Btu/

(hr-f

t-°F)

= 1

.73W

/(m-K

)

COAT

ING

THIC

KNES

S (in

ch)

U-VA

LUE

BASE

D ON

PL

OD (R

ANGE

), (B

tu/h

r-ft2

-°F

)

UNIN

SULA

TED

PIPE

(COL

D FL

OW)

COLL

APSI

BLE

PIPE

PHAS

E-CH

ANGE

INSU

LATI

ON

FLOW

OPT

IMIZ

ED S

YSTE

M

ARCH

ITEC

TURE

COIL

ED T

UBIN

G RE

MED

IATI

ON

INTE

RNAL

LY IN

SULA

TED

CORR

OSIO

N RE

SIST

ANT

PIPE

LINE

REDU

CES

/ ELI

MIN

ATES

CHE

MIC

AL

REQU

IREM

ENTS

REDU

CES

/ ELI

MIN

IATE

S EN

ERGY

RE

QUIR

EMEN

TS

MIN

IMIZ

ES C

APEX

/ IN

STEX

/ OP

EX

APPL

ICAT

ION

- WEL

LBOR

E (W

), FL

OWLI

NE (F

), RI

SER

(R),

JOIN

TS (J

T),

JUM

PERS

(JPR

)

OFFS

ET D

ISTA

NCE

(Mile

)

PIG

MON

ITOR

ING

PRES

SURE

MON

ITOR

ING

FLOW

RATE

MON

ITOR

ING

ACOU

STIC

- PL

UG D

ETEC

TION

FIBE

R OP

TICS

- PL

UG D

ETEC

TION

SAND

MON

ITOR

ING

WEL

DS

COLL

ARS

INTE

GRAT

E

PRES

SURE

RAT

INGS

NON

INVA

SIVE

CLA

MP-

ON

INVE

STIG

ATED

-ENG

INEE

RED-

DESI

GNED

PROT

OTYP

E TE

STED

FOR

HY

DROC

ARBO

N US

E

INST

ALLE

D SU

BSEA

APP

L.

INST

ALLE

D SU

RFAC

E AP

PL.

TOTA

L IN

STAL

LED

LENG

TH

SUBS

EA (m

ile)

MAX

IMUM

WAT

ER D

EPTH

TES

TED

(ft)

MAX

IMUM

WAT

ER D

EPTH

IN

STAL

LED

(ft)

OIL

FIEL

DS

GAS

COND

ENSA

TE F

IELD

S

HP /

HT F

IELD

S

WEL

LBOR

E (W

), FL

OWLI

NE (F

),

RISE

R (R

), JU

MPE

R (J

PR),

JOIN

T (J

T),

MAN

IFOL

D (M

), TR

EE (T

)

APPLICATIONEXPERIENCECONNECTION METHODDETECTION SYSTEMS

ADVANTAGES

OTHER INNOVATIVE METHODS

SOLUTION TYPES

TYPECHARACTERISTICS TYPECHARACTERISTICS TYPE

PASSIVE SYSTEMSACTIVE SYSTEMSISSUESVENDORS

ADVANCED INSULATION SYSTEMS LTD Contact: Kevin Firth, Howard Walker or Philip Watson; 11490 Westheimer Rd #850, Houston, TX 77077; Phone: +1 713-425-6342, +44 (0)7795 350875, +44(0)7740 579774 or +44 (0)7827 848667; E-Mail: [email protected]; Website: www.aisplc.com ContraThermC55-750-30PhenolicBasedPack-In-PlaceSyntacticFoamSubseaInsulation H H 0.12 0.50-10.00 0.2-1.0 H H H R,JPR,JT H H H H H H 10,000 5,500 H H H F,R,JPR,JT,M,T ContraThermC55-800-03PhenolicBasedPack-In-PlaceSyntacticFoamSubseaInsulation H H 0.11 0.50-10.00 0.2-1.0 H H H R,JPR,JT H H H H H H 10,000 5,500 H H H F,R,JPR,JT,M,T ContraThermC25-770-01SyntacticSiliconeSubseaInsulation H H 0.11 0.50-10.00 0.2-1.0 H H H R,JPR,JT H H H H H H 10,000 5,500 H H H F,R,JPR,JT,M,T ContraFlameJF120LightweightPassiveFireProofProtectionandInsulationSystem H H 0.03 0.75 0.2-1.0 H H H H R,JPR,JT H H H H H Surface Surface H H H F,R,JPR,JT ContraFlexJetFireRatedFlexibleProtectionJackets H H H 0.03 0.75 0.2-1.0 H H H H R,JPR,JT H H H H H Surface Surface H H F,R,JPR,JT C.TAGHighVisibility,NonToxic,Anti-foulingSubseaMarkers H H F,R,JPR,JT H H 5,000 H H F,R,JPR,JT ASPEN AEROGELS, INC. Contact: Mario Saba - Hydrocarbon Processing; 30 Forbes Rd., Bldg. B, Northborough, MA 01532; Phone: 514-487-8693; Fax:508-691-1200; E-Mail: [email protected]; Website: www.aerogel.com 1 Spaceloft™SubseaAerogelPipe-in-Pipe(PIP)Insulation H H H H H H H Minimized H H H H H H H H H 0.01 0.2-3.0+ 0.02-0.5 H H H H H H F,R,JT H H H H H H H 155 na 9,000 H H H F,R,JT 2 Pyrogel™XTAerogelHiTemperatureInsulation H H H H H H H H H H H H H H 0.01 0.1-10.0+ 0.02-0.5 H H H H H H F,R,JT H H H H H H H H na 9,000 H H H F,R,JT 3 Cryogel™ZAerogelCryogenicPipeInsulation H H H H H H H 0.01 0.2-10+ 0.02-0.5 H H H H H H F,R,JT H H H H H H na na BREDERO SHAW COMPANY Contact: Michael Pierce - Business Development Manager or Josh Croix - Marketing Manager;3838 N. Sam Houston Pkwy East, Suite 300, Houston, TX 77032; Telephone: 281-886-2326; Fax: 281-886-2350; E-Mail: [email protected]; [email protected]; Website: www.brederoshaw.com 4 3LayerPolypropylene H H H H 0.13 0.4 3.80 H H F,R H H H H 1,900 6,500 2,400 H H H F,R 5 3LayerPolyethylene H H H H 0.20 0.4 5.20 H H F,R H H H H 14,500 6,500 2,400 H H H F,R 6 4LayerPolypropyleneFoam H H H H H H 0.10 2.5 0.62 H H F,R H H H H H H 210 2,000 2,000 H H H F,R 4LayerPolypropyleneSolid H H H H H H 0.13 2.5 0.75 H H F,R H H H H H H 210 2,000 2,000 H H H F,R 7 ThermoFlo®-S H H H H H H 0.07 4.0 0.28 H H F,R,JT,JPR H H H H 984 950 H H F,R,JT,JPR,M ThermoFlo®-D1400 H H H H H H 0.09 4.0 0.36 H H F,R,JT,JPR H H H H 170 3,600 3,400 H H F,R,JT,JPR,M ThermoFlo®-D2000 H H H H H H 0.09 4.0 0.37 H H F,R,JT,JPR H H H H 75 5,740 5,600 H H F,R,JT,JPR,M ThermoFlo®-D2800 H H H H H H 0.10 4.0 0.41 H H F,R,JT,JPR H H H H 22 7,874 7,400 H H F,R,JT,JPR,M 8 Thermotite®PolypropyleneFoam H H H H Accordingtodesign H Accordingtodesign H H H 0.10 4.0 0.42 H H F,R,JT,JPR H H H H H 250 1,300 1,300 H H H F,R,JT,JPR Thermotite®PolypropyleneSyntactic H H H H Accordingtodesign H Accordingtodesign H H H 0.10 4.0 0.41 H H F,R,JT,JPR H H H H H 40 9,000 7,200 H H H F,R,JT,JPR Thermotite®PolypropyleneSyntactic(s35)NEW H H H H Accordingtodesign H Accordingtodesign H H H 0.09 4.0 0.39 H H F,R,JT,JPR H H H H H H H F,R,JT,JPR 9 Thermotite®DeepFoam(HighDensity) H H H H Accordingtodesign H Accordingtodesign H H H 0.10 4.0 0.44 H H F,R,JT,JPR H H H H H 35 9,000 7,200 H H H F,R,JT,JPR Thermotite®DeepFoam(LowDensity) H H H H Accordingtodesign H Accordingtodesign H H H 0.09 4.0 0.36 H H F,R,JT,JPR H H H H 0 7,000 - H H H F,R,JT,JPR 10 Thermotite®PolypropyleneCompositeSystem H H H H Accordingtodesign H Accordingtodesign H H H Accordingtodesign 4.0 0.44 H H F,R,JT,JPR H H H H H 15 7,000 7,200 H H H F,R,JT,JPR 11 Thermotite®ULTRA™FoamNEW H H H Accordingtodesign H H H 0.07 4.0 0.32 H H H H H H H F,R,JT,JPR Thermotite®ULTRA™SolidNEW H H H Accordingtodesign H H H 0.09 4.0 0.37 H H H H H H H H F,R,JT,JPR CABOT NANOGEL® AEROGEL Contacts: Aled Rees, Commercial Director: 157 Concord Rd., Billerica, MA 01821; Tel 978-670-NANO; Fax 978-670-7045. Email: [email protected] Raj Saxena, Sales Manager: 4582 Kingwood Dr. Suite E145, Kingwood, TX 77345; Tel 281-361-2330; Fax 281-361-3119. Email: [email protected]; Website: www.nanogel.com 12 Nanogel®AEROGELCOMPRESSIONPACK™ H H H H H H H H H H H 0.01 0.5-8.0 0.02-0.5 H H H F,R,JT H H 10,000 H H H F,R,JT 13 Nanogel®AEROGELEXPANSIONPACK™ H H H H H H H H H H H 0.01 1.0-8.0 0.02-0.5 H H H F,R,JT H H 10,000 H H H F,R,JT 14 Nanogel®AEROGELTHERMALWRAP™ H H H H H H H H H H H 0.01 0.1-12.0+ 0.02-0.5 H H H F,R,JT H H 10,000 H H H F,R,JT 15 Nanogel®AEROGELINFILL H H H H H H H H H H H 0.010 0.1-12.0+ 0.02-0.5 H H H F,R,JT H H 10,000 H H H F,R,JT CLAMPON, INC. Contact: Jim Boecker - Sales Manager or Sam Barton - Operations Manager; 15720 Park Row, Ste. 300, Houston, TX 77084; Phone: (281) 492-9805; Fax: (281) 492-9810; E-Mail: [email protected]; [email protected]; Website: www.clampon.com 16 DSPParticleMonitor(Sand) H H F,R,JT,JPR, H H H H H H 14,850 8,800 H H H F,R,JT,JPR,M,T 17 DSPCorrosion-ErosionMonitoring H H F,R,JT,JPR, H H H H H H H H F,R,JT,JPR,M,T 18 DSPPigDetector H H F,R,JT,JPR, H H H H H H 14,850 8,800 H H H F,R,JT,JPR,M,T DSPLeakDetector H H F,R,JT,JPR, H H H H H 14,850 1,320 H H H F,R,JT,JPR,M,T CORUS TUBES Contact: Richard Freeman - Business Development Manager or Derek Bish - Sales and Applications Engineer; P.O. Box 101, Weldon Road, Corby, Northants, UK, NN175UA; Phone: 44-1536-404262; Fax: 44-1536-404095; E-Mail: [email protected]; Website: www.corusenergy.com Pipe-in-Pipe(PIP)-LightweightStructuralSystem H H H H H 0.012-0.023 0.1-0.25 H H H F,R H H H H 8,200 H H H F,R 19 Pipe-in-Pipe(PIP)-InjectedPolyurethanefoam H H H H H 0.1-0.25 H H H F,R H H H H H 350 350 H H H F,R Pipe-in-Pipe(PIP)-Nanogel®/PolyurethaneFoamHybrid H H H H H 0.02-0.1 H H H F,R H H H H H H H F,R Hydrotherm™ H H H H 0.06 0.25-0.45 H H H F,R H H H H H 45 4,600 350 H H H F,R CUMING INSULATION CORPORATION Contact: Elmer Hershey or Larry King; 515 N. Sam Houston Parkway, E, #630, Houston, TX 77060; Phone: 281- 591-1069; Fax: 281- 591-0284; E-Mails: [email protected] or [email protected]; Website: www.bayouflow.com www.cumingcorp.com 20 C-THERMSSyntacticFoamInsulationforFlowLinesandRisers H H H H H H H 0.04-0.08 1.00-4.00 0.20-1.0 H H H F,R Various H H H H H H H 5 10,000 5,000 H H H F,R 21 C-THERMPSyntacticFoamforJumpers,Trees,Manifolds,Etc. H H H H 0.04-0.08 1.00-4.00 0.20-1.0 H H H JPR H H H H H H H 10,000 7,500 H H H T,M,JPR C-THERMFSyntacticFoamSleevesforFieldJoints,Jumpers,Etc. H H H H 0.04-0.08 1.00-4.00 0.20-1.0 H H H JPR,JT H H H H H H H 10,000 7,000 H H H JPR,JT C-THERMRSyntacticFoamHybridRiserBuoyancy&Insulation H H H H H 0.04-0.08 AsRequired 0.20-1.0 H H H R H H H H H H H 10,000 5,000 H H H R DEEPFLEX Contact: Ramon A. Perez or David Barnes - Directors of Business Development; 3350 Rogerdale, Suite 200, Houston, TX 77042; Phone: 713-334-1500; Fax: 713-334-1506; Email: [email protected]; [email protected];; Website: deepflex.com 22 DeepFlexFlexiblePipe H H 0.08 0.25-0.70 H H H F,R,JPR 25 H H H H 3.5 10,000 5,000 H H F,R,JPR DOW HYPERLAST Contact: (USA) - Mike Huspek - Global Account Manager; 901 E. Kankakee River Dr., Wilmington, IL 60481; Phone: +1 815-476-1172; Email: [email protected]. (Europe) Stuart B. Carlyle - Bus. Dev Mgr. Or Rob Ashton - Technology Leader; Station Road, Birch Vale, High Peak, Derbyshire, SK22 1BR, United Kingdom; Phone: 44-1663-748518; Fax: 44-1663-746605; E-mail: [email protected]; Web Site: www.dowhyperlast.com 23 Hyperlast™SyntacticLD512E H H H H H 0.06 0.5-5 >0.25 H H W,F,R,JT,JPR H H 7 1,150 150 H H H F,R,JPR,JT,M,T Hyperlast™Syntactic512 H H H H H 0.07 0.5-5 >0.3 H H W,F,R,JT,JPR H H H H 450 1,150 1,150 H H H F,R,JPR,JT,M,T Hyperlast™Syntactic512E H H H H H 0.07 0.5-5 >0.3 H H W,F,R,JT,JPR H H 9 1,150 500 H H H F,R,JPR,JT,M,T Hyperlast™Syntactic512R H H H H H 0.07 0.5-5 >0.3 H H W,F,R,JT,JPR H H H H 1.4 1,150 500 H H H JT,M Hyperlast™SyntacticHT512 H H H H H 0.07 0.5-5 >0.3 H H W,F,R,JT,JPR H H H H 1,150 H H H F,R,JPR,JT,M,T Hyperlast™SyntacticDW-512/150 H H H H H 0.08 0.5-5 >0.35 H H W,F,R,JT,JPR H H 80 4,500 4,020 H H H F,R,JPR,JT,M Hyperlast™SyntacticDW-512/150E H H H H H 0.08 0.5-5 >0.35 H H W,F,R,JT,JPR H H 73 4,500 3,915 H H H F,R,JPR,JT,M Hyperlast™SyntacticDW-512/200E H H H H H 0.09 0.5-5 >0.35 H H W,F,R,JT,JPR H H 103 6,600 5,030 H H H F,R,JPR,JT,M Hyperlast™SyntacticDW-512/300 H H H H H 0.1 0.5-5 >0.35 H H W,F,R,JT,JPR H H H 200 10,000 7,645 H H H F,R,JPR,JT,M Hyperlast™SyntacticDW-512/300E H H H H H 0.1 0.5-5 >0.35 H H W,F,R,JT,JPR H H 5 10,000 6,860 H H H F,R,JPR,JT,M Hyperlast™FJ589 H H H H H 0.11 0.5-5 >0.45 H H W,F,R,JT,JPR H H H 10,000 6,200 H H H F,JPR,JT,M Hyperlast™FJ902 H H H H H 0.11 0.5-5 >0.45 H H W,F,R,JT,JPR H 10,000 H H H F,JPR,JT,M Hyperlast™FJ125 H H H H H 0.11 0.5-5 >0.45 H H W,F,R,JT,JPR H 10,000 1,550 H H H F,JPR,JT,M Hyperlast™FJ302 H H H H H 0.11 0.5-5 >0.45 H H W,F,R,JT,JPR H H H 10,000 H H H F,JPR,JT,M Hyperlast™FJ303 H H H H H 0.11 0.5-5 >0.45 H H W,F,R,JT,JPR H H H 10,000 4,885 H H H F,JPR,JT,M Hyperlast™FJ439E H H H H H 0.11 0.5-5 >0.45 H H W,F,R,JT,JPR H 10,000 H H H F,JPR,JT,M Hyperlast™FJ548E H H H H H 0.11 0.5-5 >0.45 H H W,F,R,JT,JPR H H H 10,000 H H H F,JPR,JT,M Hyperlast™FJ689E H H H H H 0.11 0.5-5 >0.45 H H W,F,R,JT,JPR H 10,000 H H H F,JPR,JT,M Hyperlast™FJFRigidPUFoamforFieldJoint H H H H 0.05-0.2 H H H F,R,JT,JPR H H H H H H H H F,R,JPR,JT,M Hyperlast™PUFRigidPUFoamforflowlineinsulation H H H H H 0.01 0.5-6 <0.033 H H H F,R H H H H H H H H F,R,JPR,JT,M DYNA MONITORING CORPORATION Contact: Glen Sumner - 8306 Leafy Lane, Houston, Texas 77055; Phone 713-973-7285; Fax 713-973-7286; E-mail: [email protected] 24 AquaThermSubmersibleInsulation-(solid,verycosteffective) H H H H H H H 0.1 >1 0.2-1.3 H H H 1to25 H H 8,000 2,100 H H H F,R,JT,JPR,M,T 25 HysulateSubmersibleInsulation(400degreeoperatingtemperature) H H H H H 0.02 >0.25 0.37-8 H H H H H 4,500 1,500 H H H W,F,R,JT,JPR,M,T Proprietaryelectricflowlineheating(returncableoptional) H H H H asneeded C Y 0-25 H H H H H 1to25 H H 4,500 H H H F,R,JT,JPR FMC TECHNOLOGIES Contact: Eric Heuring - Global Thermal Insulation Manager or Michael Coles - Technical Manager; 1777 Gears Rd., Houston, TX 77067; Phone 281-591-4578; Fax: 281-405-4937-Mail: [email protected]; Website: www.fmctechnologies.com Novotherm™ H H 0.1 1.0-3.0 0.35-0.12 H R,JT,JPR H H H H H 10,000 7,000 H H JPR,JT,M,T 26 Novolastic™HT H H 0.1 1.0-3.0 0.35-0.12 H R,JT,JPR H H H H H 10,000 9,350 H H JPR,JT,M,T HeatTracingforSubseaHardware 10-30kW 1.0-3.0 0.35-0.12 H H H H H H JPR,M,T FOSTER WHEELER OPE UPSTREAM Contact: Richard Gaona - Marketing Manager; 585 North Dairy Ashford, Houston, TX 77079; Phone: 713-929-5000; Fax: 713-929-5188; E-Mail: [email protected]; Website: www.opeinc.com SingleInsulatedPipelineandRiser H H H H H H H H H H H 0.85 0.5-5 >0.35 H H H H F,R,JT,JPR H H H H H H H H 10,000 9,000 H H H F,R,JT,M SyntacticFoamforJumpers,Trees,Manifolds,Etc. H H H H H 0.85 0.5-5 >0.35 H H H H F,R,JT,JPR H H H H H H H H 10,000 9,000 H H H JPR,M,T Pipe-in-PipePipelineandRiser H H H H H H H H H H H 0.01 0.25-3.0 0.02-0.5 H H H H F,JT H H H H H H H H 10,000 8,000 H H H F,JT LPGCryogenicPipeline H 0.02 1.1 0.2 H H F,JT H H H 0.15 115 H H F,JT,M LNGCryogenicPipeline H H 0 1 0.03 H H H F,JT H H H H F,JT,M ITP INTERPIPE Contact: (USA) - Vicki Niesen;16360 Park Ten Place, Suite 327, Houston, TX 77084; Phone: 281-492-2576: E-Mail: [email protected]. (Europe) - Wayne Grobbelaar; 11 Quai Conti, 78430 Louveciennes, France; Phone: (+33) 180 108 091; [email protected]; Website: www.itp-interpipe.com 27 HighlyInsulatedDoubleWallPipe H H H H 0.0030-0.01 0.2-1 0.05-0.4 H H H F,R 60 H H H H 160 10,000 4800 H H H F,R,J 28 LightWeightDoubleWallPipe H H H H 0.0030 <1 0.05-0.4 H H H F,R 60 H H H 10,000 H H H F,R 29 UltimatePipe H H H 0.010 <1 0.15-0.4 H H H F,R 40 H H H 10,000 H H F,R,J 30 McPipe(10DaysCooldown)Developedw/J.RayMcDermott,Inc. H H H H 0.0030 1-2 0.05-0.3 H H H H F,R 60 H H H 10,000 H H F,R,J 31 HeatTracedPipe H H H 8-20kW H H 0.0030 <1 0.05-0.25 H H H F,R 60 H H H 6,500 H H F,R,J 32 LPGRefrigeratedPipe H 0.0030 1-2 0.01-0.1 H H F,R 15 H H H H H 4 50 50 F,R 33 LNGCryogenicPipe H 0.0025 2 0.01-0.03 H H F,R 15 H H H 50 F,R NEXANS NORWAY Contact: Marc Joyce - VP Business Development; 16420 Park Ten Place, Suite 580, Houston, TX 77084; Phone: 281-578-6900; Fax: 281-578-6991; E-Mail: [email protected]; Website: www.nortech.com or Bjorn Bjornstad, Innspurten 9, PO Box 6450, 0605 Oslo, Norway; Phone: 4722886100; Fax: 4722886378; E-Mail: [email protected]; Website: www.nexans.com 34 DEH H H H H H H H H 0.1 .52-1.76 H H H H H 140 2,790 1200 H H H F,JT,R PERMA-PIPE OIL & GAS Contact: Hank C. Reuser - Vice President or Chris Weierman - Technical Sales Engineer; 515 N. Sam Houston Parkway E, #630, Houston, TX 77060; Phone: 281- 598-6222; Fax: 281- 591-0284; E-Mails: [email protected] & [email protected]; Website: www.permapipe.com 35 AUTO-THERMGlassSyntacticPolyurethane(GSPU)forFlowlines&Jumpers H H H H H H H 0.07 0.50-4.00 0.4-2.0 H H H H F,R,JT,JPR H H H H H >100miles 10,000 10,000 H H H F,R,JT,JPR 36 AUTO-THERMGlassSyntacticPolyurethaneforSubseaEquipment H H 0.08 0.50-4.00 0.4-2.0 H H H F,R,JT,JPR H H H H H 10,000 4,000 H H H F,R,JT,JPR,M,T 37 XTRU-THERMMidtoHighDensityWetInsulationPUwithPEJacket H H H H H H H H 0.02 0.75-5.00 0.15 H H H F,R,JT,JPR H H H H H 36miles 650 575 H H H F,R,JT 38 XTRU-THERMPipe-in-Pipe(PIP)PolyurethaneFoamwithPEJacket H H H H H H H 0.02 0.75-4.00 0.1 H H H F,R,JT H H H H H 250miles 10,000 7500 H H H F,R,JT 39 XTRU-THERMCryogenicPipeline-MidDensityPUFoamwithPEJacket H H 0.01 0.75-6.00 0.03 H H H H H H H 2miles H F,JT ROXAR Contact: Chris McPherson; 3300 Walnut Bend Lane, Houston, TX 77042; Phone: 713-334-2222; E-Mail: Chris. [email protected]; Website: www.roxar.com 40 SandandErosionMonitoringSystem H W,F,R,JT,JPR H H H H H 10,000 7,800 H H H W,F,R,JT,T 41 FSM™Corrosion/ErosionMonitoringSystem H H H H H H W,F,R,JT,JPR H H H H 10,000 6,500 H H H F,R,JT 42 Pressure/TemperatureMonitoring H H H W,F,R,JT,JPR H H H H H H 10,000 7,800 H H H W,F,R,JT,M,T FlowForce H H H W,F,R,JT,JPR H H H H H 10,000 1,000 H H H W,F,R,JT,M,T 43 RoxarSubseaMPFM H H H W,F,R,JT,JPR H H H H H H H H 10,000 9,000 H H H W,F,R,JT,M,T 44 RoxarSubseaSandmonitor/Pigdetector H H F,R,JT,JPR H H H H H H H 9,842 9,600 H H H F,R,JT,JPR,M,T SAIPEM Contact: Luc Poirson, Saibos SAS; rue Stephenson, 78 884 St. Quentin en Yvelines Cedex, France; Phone: 33-161-37-6661; e-mail: [email protected]; Loic Delebecque, Saipem SA; Bat. Energies, TEDE 1/7 avenue San Fernando, 78884 St. Quentin en Yvelines, France; Phone: 33-161-37-7286; Fax: 33-161-37-8380; e-mail: [email protected] 45 BundleHybridOffsetRiser(BHOR)-RiserTower H H H H H 0,007-0,07 0.25-2.0 0.16 H H H R H H H H H 2.5 10,000 4,000 H H H R PipeinPipeSingleHybridRiser(PiPSHR) H H H 0,1-0,13 1-5 0.36 H H H R H H H H 2 10,000 3,400 H H H R PUfoaminsulatedPipeinPipe(PUFPiP) H H H 0,012-0,024 0,5-6 0.18 H H H F,R H H H H 24 10,000 3,400 H H H F,R 46 AerogelinsulatedPipeinPipe H H H 0.01 0,25-2,0 0.16 H H H F,R H H H H 6 10,000 4,200 H H H F,R Vactub®-VacuuminsulatedPipeinPipe H H H H 0 1 0.09 H H H F,R H H H 10,000 H H H F,R Gelinsulatingmaterial H H H 0.08 H H H F,R,JPR,JT H H 10,000 H H F,R,JPR,JT 47 GelILS-Phasechangeinsulatingmaterial H H H 0.11 H H H H F,R,JPR,JT H H 10,000 H H F,R,JPR,JT Gel/GelILSproductionFlowline H H H 0,084-0,11 1-6 0.32 H H H H F,R H H H 10,000 H H F,R 48 GelproductionBundle H H H 0.08 1-8 0,14-0,28 H H H F H H H 10,000 H H F SinglePipeFlowline&Riser H H H 0.1-0.13 4 0.47 H H H F,R,JPR H H H H 33 10,000 4,600 H H F,R,JPR SOCOTHERM AMERICAS Contact: Cristian Grecco; Ruta 9, km 52.3 Escobar, Buenos Aires, Argentina (1625); Phone: +54.3488.433.500; e-mail: [email protected]; Website: www.socotherm.com.ar 49 Plastykote®ThreeLayerPolyethylene H H H 0.13 0.06-0.5 >1.90 H H H F,R,JT,JPR H H H H H H 35,000 10,000 8,200 H H H F,R,JT,JPR 50 Plastykote®ThreeLayerPolypropylene H H H 0.2 0.06-0.5 >1.90 H H H F,R,JT,JPR H H H H H H 5,000 10,000 8,200 H H H F,R,JT,JPR 51 Wetisokote®FiveLayerSolidPolypropylene H H H Acc.todesign H H H 0.13 0.5-6.0+ >0.40 H H F,R,JT,JPR H H H H H H 60 10,000 6,600 H H H F,R,JT,JPR 52 Wetisokote®FiveLayerPolypropyleneFoam H H H Acc.todesign H H H 0.095-0.101 0.5-6.0+ >0.35 H H F,R,JT,JPR H H H H H H 104 2,000 1,800 H H H F,R,JT,JPR 53 Wetisokote®FiveLayerSyntacticPolypropylene H H H Acc.todesign H H H 0.081-0.092 0.5-6.0+ >0.35 H H F,R,JT,JPR H H H H H H 165 10,000 8,200 H H H F,R,JT,JPR 54 Thermakote®HighDensityPolyurethaneFoam H H H Acc.todesign H H H 0,02-0,03 1,0-4,0 >0.10 H H F,R,JT,JPR H H H H H H 60 650 330 H H H F,R,JT,JPR 55 PipeinPipe H H H Acc.todesign H H H >0.018 AnnularGap 0.10-0.36 H H F H 100 10,000 5,000 H H H F SOCOTHERM LABARGE Contact: Hermann Buschor, Fernando Ulecia; 817 Shields Street Channelview, TX 77530, USA; Phone: +1713.378.7200; e-mail: [email protected]; [email protected]; Website: www.socothermlabarge.com 49 Plastykote®ThreeLayerPolyethylene H H H 0.13 0.06-0.5 >1.90 H H H F,R,JT,JPR H H H H H H 35,000 10,000 8,200 H H H F,R,JT,JPR 50 Plastykote®ThreeLayerPolypropylene H H H 0.2 0.06-0.5 >1.90 H H H F,R,JT,JPR H H H H H H 5,000 10,000 8,200 H H H F,R,JT,JPR 51 Wetisokote®FiveLayerSolidPolypropylene H H H Acc.todesign H H H 0.13 0.5-6.0+ >0.40 H H F,R,JT,JPR H H H H H H 60 10,000 6,600 H H H F,R,JT,JPR 52 Wetisokote®FiveLayerPolypropyleneFoam H H H Acc.todesign H H H 0.095-0.101 0.5-6.0+ >0.35 H H F,R,JT,JPR H H H H H H 104 2,000 1,800 H H H F,R,JT,JPR 53 Wetisokote®FiveLayerSyntacticPolypropylene H H H Acc.todesign H H H 0.081-0.092 0.5-6.0+ >0.35 H H F,R,JT,JPR H H H H H H 165 10,000 8,200 H H H F,R,JT,JPR 54 Thermakote®HighDensityPolyurethaneFoam H H H Acc.todesign H H H 0,02-0,03 1,0-4,0 >0.10 H H F,R,JT,JPR H H H H H H 60 650 330 H H H F,R,JT,JPR TECHNIP Contact: Yogesh Kapoor or Juan Manzano - Account Managers, 11700 Katy Freeway, Suite 150 - Houston, TX 77079; Phone: 281-870-1111; Fax: 281-249-7646; Email: [email protected] or [email protected]; Website: www.technip.com Multi-PassPlough/Back-FillPlough H H H 0.6-1.5 F H H H H H 1,250 1,640 1,020 H H H F Flexjet1Trencher H H H 0.6-1.5 F H H H H H >450 1,640 1,150 H H H F TM9Trencher H H H 0.6-1.5 F H H 197 1,000 660 H H H F SinglePipeFlowline&Riser H H H 0.04-0.17 0.0-4.0 >0.5 F,R,JPR H H H H H H H 2,150 10,000 4,510 H H H F,R,JPR Pipe-in-PipeFlowline&Riser H H H 0.007-0.02 0.0-0.5 >0.09 H H H F,R,JPR H H H H H H H 10,000 6,900 H H H F,R,JPR ElectricallyHeatedPipe-in-PipeFlowline&Riser H H H H 24-240kW H H H H H 0.007-0.02 0.0-0.6 >0.1 H H F,R,JPR H H H H H H H 10,000 H H H F,R,JPR PlasticallyLinedPipelineforWaterInjectionService H H H 0.04-0.17 0.0-4.0 >0.5 H H F,R H H H H H H 10,000 H H H F,R PlasticallyLinedPipelineforHydrocarbonTransport H H H H H 0.04-0.17 0.0-4.0 >0.5 H H F,R H H H H H 10,000 H H H F,R IntegratedProductionBundle H H H H H H H F,R,JPR H H H H 10,000 H H H F,R,JPR NGCryogenicPipe-in-Pipe H 0.01 2.3-3.1 0.016-0.022 H H H H H 50 F,R LNGCryogenicFlexibleHose H H H H H H JPR TRELLEBORG OFFSHORE (IncorporatingTrelleborgOffshoreUSInc.,TrelleborgOffshoreUKLtd.,TrelleborgOffshoreNorwayA.S) Contact: (USA) - Jim Haslam - Sales Manager - Thermal Insulation. Trelleborg Offshore US, Inc. 519 N Sam Houston Pkwy E, Suite 200 Houston, TX 77060 Direct: +8324568358 Mobile: +2817434031 E-Mail: [email protected]. (Europe) Ben Wait - Sales Manager - Thermal Insulation, Trelleborg Offhshore UK Ltd. Paxton Place, West Pimbo, Skelmersdale, Lancashire WN8 9QH, UK, Phone +44 (0) 1695 714332, Fax: +44 (0)1695 555586; E-Mail: [email protected], Website: www.trelleborg.com/offshore. 56 ARDENT™-(HighTemperaturePhenoilcSyntactic) H H H H H 0.18 0.5-6.0 >0.29 H H H R,JT,JPR H H H H H H 9,800 H H H F,R,JT,JPR,M,T 57 URATHERM™-S250(SyntacticPolyurethane) H H H H H 0.06 0.5-6.0 >0.18 H H H F,R,JT,JPR H H H H H >50(B) 720 720 H H H F,R,JT,JPR,M,T 58 URATHERM™-G3000(SyntacticPolyurethane) H H H H H 0.1 0.5-6.0 >0.28 H H H F,R,JT,JPR H H H H H >2200(B) 6,560 6,560 H H H F,R,JT,JPR,M,T 59 URATHERM™-G3000HT(SyntacticPolyurethane) H H H H H 0.09 0.5-6.0 >0.27 H H H F,R,JT,JPR H H H H H 7,320 H H H F,R,JT,JPR,M,T 60 URATHERM™-P7000(Polyurethane) H H H H H 0.11 0.5-6.0 >0.32 H H H F,R,JT,JPR H H H H H >25 23,000 23,000 H H H F,R,JT,JPR,M,T URATHERM™-PIP(FoamedPolyurethaneforPipeInPipesystems) H H H 0.01 0.5-6.0 >0.033 H H H F,R H H H H >20 N/A N/A H H H F,R 61 ULTRATHERM™-1500(SyntacticFoam) H H H H H 0.06 0.5-6.0 >0.16 H H H F,R,JT,JPR H H H H H >200(B) 6,560 5,085 H H H F,R,JT,JPR,M,T 62 ULTRATHERM™-2000(SyntacticFoam) H H H H H 0.07 0.5-6.0 >0.19 H H H F,R,JT,JPR H H H H H 8,200 4,265 H H H F,R,JT,JPR,M,T ECCOTHERM®7000 H H H H 0.07 0.5-6.0 >0.23 H H H F,R,JT,JPR H H H H H >1 23,000 23,000 H H H F,R,JT,JPR,M,T 63 ECCOTHERM®PT1000 H H H H 0.09 0.138perlayer >1 H H H F,R H H H H H >50 1,000 H H H F,R 64 ECCOTHERM®PT3000 H H H H 0.09 0.138perlayer >1 H H H F,R H H H H H >50 3,000 2,000 H H H F,R ECCOTHERM®PT7000CBlue H H H H 0.1 0.138perlayer >1 H H H F,R H H H H H >100 7,000 4,000 H H H F,R 65 THERMOGEL™3000 H H H H � 0.07 Gel >0.2 H H H W,JT H H H H 9,800 700 H H H F,R,JT,JPR 66 VIKOTHERM-HISCprotection H H H H H H H � 0.075 0.15-6.0 >0.3 H H H W,R,JT,JPR H H H H H H H >10 6,560 5,000 H H H W,F,R,JPR,JT,M,T 67 VIKOTHERM-Hightempresistant H H H H H H H � 0.075 0.15-6.0 >0.3 H H H W,R,JT,JPR H H H H H H H >10 6,560 5,000 H H H W,F,R,JPR,JT,M,T 68 VIKOTHERM-Standard H H H H H H H � 0.075 0.15-6.0 >0.3 H H H W,R,JT,JPR H H H H H H H >10 6,560 5,000 H H H W,F,R,JPR,JT,M,T WELLSTREAM INTERNATIONAL, LTD. Contact: Tricia Hill - VP, Business Development North America; 11210 Equity Drive, Suite 350, Houston, TX 77041; Phone: 281-249-0925; Fax: 713-431-0884; E-Mail: [email protected]; (2)Contact: Shawn Goertz - Technical Sales; Phone: 281-249-0936; Email: [email protected]; Website: www.wellstream.com 69 WellstreamFlexiblePipe H H H H 0.08 0.25-0.70 H H H F,R,JPR 15.5 H H H H 600 10,000 6,500 H H H F,R,JPR

WATER DEPTH (ft)

4,00

0'

0' 2,00

0'

1,00

0'

3.00

0'

5.00

0'

6,00

0'

7,00

0'

8,00

0'

9,00

0'

10,0

00'

5,500 10,000

10,0007,500

4,000 10,000

10,000

4,500

10,0008,0002,100

10,000

10,000

7,200 10,000

CONCEPTUAL

PROTOTYPE

FIELD PROVEN

9,000 unlimited

5,000

5,000 10,000

10,0007,000

10,0002,400 6,50010,0002,400 6,500

2,000

8,500575 7,400

1,150

7,200 9,0007,000

7,200 10,000

10,00010,00010,000

10,000+8,800

10,000+8,80010,000+

10,000+1,320

10,000350

10,0004,600350

10,0008,200

10,000

1,150500

10,000

10,000

6,6005,03010,0007,64510,0006,86010,0006,200

10,0001,550

10,0004,885

4,5001,500

10,0007,00010,0009,000

4,800 10,000

6,500 10,000

10,0002,7901,200

10,0007,80010,0006,50010,0007,800

10,0009,0009,600

1,000 10,000

3,400 10,000

4,200 10,0004,200 10,000

10,0009,000

10,0006,600

10,000

10,0008,200

10,0006,500

9,840720

7,3206,560

10,000+8,2004,265

1,0003,0002,000

7,0004,0009,840700

6,5605,000

1,00066010,0004,510

1,150 1,6401,6401,020

100

(Btu

/hr.f

t2 .°F)

- 56

7 W

/m2 .K

50 (B

tu/h

r.ft2 .°

F) -

284

W/m

2 .K

10 (B

tu/h

r.ft2 .°

F) -

57 W

/m2 .K

5 (B

tu/h

r.ft2 .°

F) -

28 W

/m2 .K

0.5

(Btu

/hr.f

t2 .°F)

- 2.

8 W

/m2 .K

0.05

(Btu

/hr.f

t2 .°F)

- 0.

3 W

/m2 .K

1 (B

tu/h

r.ft2 .°

F) -

5.7

W/m

2 .K

0.1

(Btu

/hr.f

t2 .°F)

- 0.

6 W

/m2 .K

0.01

(Btu

/hr.f

t2 .°F)

- 0.

06 W

/m2 .K

U-VALUE (Btu/hr-ft2-°F) Based on PL OD

1.9

<0.0330.05 - 0.2

3.8

0.6

0.200.20

0.02

0.020.020.020.02

>0.25>0.30

>0.35>0.35>0.35>0.35>0.45>0.45>0.45>0.45>0.45>0.45>0.45>0.45

1.3 - 0.2

0.160.360.180.16

0.09

0.32

0.47

Material used in sealed pipe in pipe systems (PIP) - not water depth dependant in this application

>0.5

>0.1

>0.05

>0.09

>0.26>0.26>0.26>0.2

>0.1>0.1>0.1

>0.23>0.19>0.16

>0.033

>0.28>0.18>0.29

8,200 10,00010,000

10,00010,00010,000

10,0004,600 9,2001,150

4,2005,9005,600

2,000

6,000

5,000

5,000 10,000

5,000 10,000

1,1501,150

1,150

10,00010,00010,00010,000

4,020 4,5003,915 4,500

10,0008,00010,0008,00010,0009,000

10,000

10,00010,00010,000

10,00010,000

10,000

10,0007,500

4,000 10,000

3,400 10,000

10,0009,00010,0009,00010,0009,000

4,600 10,000

10,0008,200

2,0001,80010,0008,200

5,000 10,000

10,0006,600

10,0008,20010,0008,200

2,0001,80010,0008,200

10,0006,900

10,00010,00010,000

6,5605,0006,5605,000

10,000+

6,5605,085

0.200.200.20

0.020.02

5.3

0.750.280.360.370.410.420.410.390.440.36

0.320.37

0.44

0.05-0.250.1-0.25

0.02-0.20.25-0.5

0.200.200.200.20

0.25

>0.35

>0.30>0.30>0.30

8 - 0.37

0.35-0.120.35-0.120.35-0.12

>0.35>0.35

0.020.2

0.029

0.4 - 0.050.4 - 0.05

0.4- 0.150.3 - 0.05

0.25 - 0.050.1 - 0.01

0.03-0.01

1.76 - 0.52

0.50.5

0.150.10

0.03

0.18

1.91.9 - 0.401.9 - 0.351.9 - 0.35

0.70 - 0.100.36 - 0.10

1.91.9

1.9 - 0.401.9 - 0.351.9 - 0.35

0.70 - 0.10

>0.27>0.32

0.25

2 3

5 6 7 8

49 50 51 52

53 54 55

1

10 11 12 13 14 15

16 17 18 20 21 22

25 26 27 28 29

33 35 36 37

38 39

43 44 45 46

47

48

PermaREV_OSmaps_1004 1 3/19/10 2:51 PM

Engineering Polymer Excellence

A Pipeline Flow Assurance PartnerDow Hyperlast’s professionals work with industry leaders and applicators to specify, support, and service systems that ensure pipeline performance throughout the life of the line.

�������������������������������� ������������

������������������������������������������������������������������

����������������������������������������������������������������������������������

���������������������������������������

�������������������������

�� �­�������������������������������������������

www.dowfl owassurance.com

DowHyp_OSmaps_1004 1 3/19/10 10:42 AMClampon_OSpos_1004 1 2/8/10 2:59 PM

BreSha_OSmap_1004 1 3/16/10 9:52 AM

cabot-corp.com/aerogel.com

UNSURPASSED THERMAL PERFORMANCE

UNRIVALED TECHNICAL EXPERTISE

UNMATCHED VERSATILITY OF PRODUCT FORM

CabAer_OSmap_1004 1 3/15/10 11:50 AM

Techn_OSmaps_1004 1 3/11/10 4:12 PM

O c e a n s c o v e r 2 8 5 b i l l i o n b a r r e l s o f t h e w o r l d ’s k n o w n o i l r e s e r v e s – O F F S H O R E c o v e r s t h e m a l l .

M A G A Z I N E

World Trends and Technology for Offshore Oil and Gas Operations

2010 Petroleum events calendarOil Sands and Heavy Oil Technologies Conference & ExhibitionJuly 20 – 22, 2010 | Calgary, Alberta, Canadawww.oilsandstechnologies.com

World Energy CongressSept. 12 – 16, 2010 | Montréal, Quebec, Canadawww.wecmontreal2010.ca

Offshore Middle East Conference & ExhibitionOct. 12 – 14, 2010 | Doha, Qatarwww.offshoremiddleeast.com

Deep Offshore Technology International Conference & Exhibition – AmsterdamNov. 30 – Dec. 2, 2010 | Amsterdam, Netherlandswww.deepoffshoretechnology.com

Oil & Gas Maintenance Technology North America Conference & ExhibitionAug. 31 – Sept. 2, 2010 | New Orleans, Louisiana USAwww.ogmtna.com

Unconventional Gas InternationalConference & ExhibitionOct. 5 – 7, 2010 | Ft. Worth, Texas USAwww.unconventionalgas.net

Deepwater Operations Forum & ExhibitionNov. 2 – 4, 2010 | Galveston, Texas USAwww.deepwateroperations.com

Protecting the pipelines that bring energy to the world

Hermann Buschor

[email protected]

Fernando Ulecia

[email protected] www.SocothermLaBarge.com

Socotherm LaBarge LLC817 Shields Street

Channelview, Texas 77530Toll Free 866.992.4191

Insulation and Coatings Technology for Deepwater Pipelines, Flowlines, and Risers

For a hot product in a cold environment...

We keep you insulated

Phone: 713.378.7200 | Fax: 713.378.7299Contact:

SocLab_OSmaps_1004 1 2/19/10 3:58 PM

0410OS_FlowPoster032510APP.indd 1 3/25/10 4:59:55 PM