26
6 Configuring BSC Links About This Chapter This topic describes how to configure BSC links for the signaling transmission within the BSC and between the BSC and other network elements. BSC links are the links on the Ater interface, A interface, and Pb interface. 6.1 Configuring Links on the Ater Interface This topic describes how to configure links on the Ater interface for the signaling transmission between the GMPS or the GEPS and the GTCS. The links on the Ater interface are the Ater connection path, Ater OML, and Ater signaling link. 6.2 Configuring Links on the A Interface This topic describes how to configure E1 connections and SS7 signaling links on the A interface for the communication between the BSC and the MSC. 6.3 Configuring Links on the Pb Interface This topic describes how to add a PCU and configure E1 connections and signaling links on the Pb interface for the communication between the BSC and the PCU. HUAWEI BSC6000 Base Controller BSC Initial Configuration Guide 6 Configuring BSC Links Issue 01 (2007-09-05) Huawei Technologies Proprietary 6-1

01-06 Configuring BSC Links

Embed Size (px)

Citation preview

6 Configuring BSC Links

About This Chapter

This topic describes how to configure BSC links for the signaling transmission within the BSCand between the BSC and other network elements. BSC links are the links on the Ater interface,A interface, and Pb interface.

6.1 Configuring Links on the Ater InterfaceThis topic describes how to configure links on the Ater interface for the signaling transmissionbetween the GMPS or the GEPS and the GTCS. The links on the Ater interface are the Aterconnection path, Ater OML, and Ater signaling link.

6.2 Configuring Links on the A InterfaceThis topic describes how to configure E1 connections and SS7 signaling links on the A interfacefor the communication between the BSC and the MSC.

6.3 Configuring Links on the Pb InterfaceThis topic describes how to add a PCU and configure E1 connections and signaling links on thePb interface for the communication between the BSC and the PCU.

HUAWEI BSC6000 Base ControllerBSC Initial Configuration Guide 6 Configuring BSC Links

Issue 01 (2007-09-05) Huawei Technologies Proprietary 6-1

6.1 Configuring Links on the Ater InterfaceThis topic describes how to configure links on the Ater interface for the signaling transmissionbetween the GMPS or the GEPS and the GTCS. The links on the Ater interface are the Aterconnection path, Ater OML, and Ater signaling link.

1. 6.1.1 Configuring the Ater Connection PathThis topic describes how to configure the connection path between the GMPS and the GTCSas well as between the GEPS and the GTCS on the Ater interface.

2. 6.1.2 Adding an Ater OMLWhen the GTCS is configured on the MSC side, you have to add an Ater OML betweenthe GMPS and the main GTCS. The Ater OML transmits the OM information to the GTCS.

3. 6.1.3 Adding an Ater Signaling LinkWhen the GTCS is configured on the MSC side, the Ater connection path between theGMPS or GEPS and the GTCS must be configured with an Ater signaling link. The Atersignaling link transmits the signaling of service control, TC resource management, and Atertransmission resource management.

6.1.1 Configuring the Ater Connection PathThis topic describes how to configure the connection path between the GMPS and the GTCS aswell as between the GEPS and the GTCS on the Ater interface.

Scenario BSC initial configuration

Mandatory/Optional

Mandatory

NOTE

l A maximum of 32 Ater connection paths can be configured between two GEIUTs.

l A maximum of 63 Ater connection paths can be configured between two GOIUTs.

l A maximum of 32 Ater connection paths can be configured between the GOIUT and the GEIUT.

l The Ater interface E1 that is configured with the semipermanent connection should not be configuredwith the Ater connection path.

Prerequisitel The two subracks between which the Ater connection path is to be established are

configured.

l The GEIUT/GOIUT in the two subracks between which the Ater connection path is to beestablished is configured.

PreparationNOTE

This parts describes how to configure the Ater connection path between the GMPS and the GTCS as wellas between the GEPS and the GTCS.

6 Configuring BSC LinksHUAWEI BSC6000 Base Controller

BSC Initial Configuration Guide

6-2 Huawei Technologies Proprietary Issue 01 (2007-09-05)

Table 6-1 Example of data to be negotiated and planned for configuring the Ater connectionpath between the GMPS and the GTCS

Parameter Example Source

BM Subrack No. 0 BSC internal planning

BM Slot No. 16 BSC internal planning

BM Port No. 0 BSC internal planning

TC Subrack No. 6 BSC internal planning

TC Slot No. 16 BSC internal planning

TC Port No. 0 BSC internal planning

Table 6-2 Example of data to be negotiated and planned for configuring the Ater connectionpath between the GEPS and the GTCS

Parameter Example Source

BM Subrack No. 1 BSC internal planning

BM Slot No. 16 BSC internal planning

BM Port No. 0 BSC internal planning

TC Subrack No. 7 BSC internal planning

TC Slot No. 16 BSC internal planning

TC Port No. 0 BSC internal planning

Procedurel Configure the Ater connection path between the GMPS and the GTCS.

1. On the BSC6000 Local Maintenance Terminal, right-click a GEIUT in the GMPS. Ashortcut menu is displayed, as shown in Figure 6-1.

Figure 6-1 GEIUT shortcut menu

NOTE

The configuration of the Ater connection path can be started only on the GEIUT/GOIUT.

2. Choose Configure Ater Connection Path. A dialog box is displayed, as shown inFigure 6-2.

HUAWEI BSC6000 Base ControllerBSC Initial Configuration Guide 6 Configuring BSC Links

Issue 01 (2007-09-05) Huawei Technologies Proprietary 6-3

Figure 6-2 Configuring the Ater connection path

3. Click Add. A dialog box is displayed, as shown in Figure 6-3.

Figure 6-3 Adding an Ater connection path

4. Set the parameters according to the data listed in Table 6-1.5. Click Finish. The configuration of the Ater connection path between the GMPS and

the GTCS is complete.6. Repeat 1 through 5 to add more Ater connection paths between the GMPS and the

GTCS.

6 Configuring BSC LinksHUAWEI BSC6000 Base Controller

BSC Initial Configuration Guide

6-4 Huawei Technologies Proprietary Issue 01 (2007-09-05)

l Configure the Ater connection path between the GEPS and the GTCS.1. Right-click a GEIUT in the GEPS. A shortcut menu is displayed, as shown in Figure

6-4.

Figure 6-4 GEIUT shortcut menu

NOTE

The configuration of the Ater connection path can be started only on the GEIUT/GOIUT.

2. Choose Configure Ater Connection Path. A dialog box is displayed, as shown inFigure 6-5.

Figure 6-5 Configuring the Ater connection path

3. Click Add. A dialog box is displayed, as shown in Figure 6-6.

HUAWEI BSC6000 Base ControllerBSC Initial Configuration Guide 6 Configuring BSC Links

Issue 01 (2007-09-05) Huawei Technologies Proprietary 6-5

Figure 6-6 Adding an Ater connection path

4. Set the parameters according to the data listed in Table 6-2.5. Click Finish. The configuration of the Ater connection path between the GEPS and

the GTCS is complete.6. Repeat 1 through 5 to add more Ater connection paths between the GEPS and the

GTCS.

----End

6.1.2 Adding an Ater OMLWhen the GTCS is configured on the MSC side, you have to add an Ater OML between theGMPS and the main GTCS. The Ater OML transmits the OM information to the GTCS.

Scenario BSC initial configuration

Mandatory/Optional

Optional. When the GTCS is configured on the MSC side, you have to add anAter OML between the GMPS and the main GTCS.

NOTE

l An active and a standby Ater OMLs are usually configured. The timeslot masks of the two links mustbe the same.

l The timeslot mask of an Ater OML must contain TS1 and at least four successive timeslots.

Prerequisitel The GTCS is configured on the MSC side.

l The Ater connection path between the GMPS and the main GTCS is configured.

6 Configuring BSC LinksHUAWEI BSC6000 Base Controller

BSC Initial Configuration Guide

6-6 Huawei Technologies Proprietary Issue 01 (2007-09-05)

Preparation

Table 6-3 Example of data to be negotiated and planned for adding an OML

Parameter Example Source

Logical Group No. 0 BSC internal planning

Ater Connection PathIndex

0 BSC internal planning

BM Subrack No. of AterConnection Path

0 BSC internal planning

Timeslot Mask TS1, TS2–TS17 BSC internal planning

Procedure

Step 1 On the BSC6000 Local Maintenance Terminal, right-click a GEIUT in the GMPS. A shortcutmenu is displayed, as shown in Figure 6-7.

Figure 6-7 GEIUT shortcut menu

NOTE

The configuration of the Ater OML can be started only on the GEIUT/GOIUT in the GMPS.

Step 2 Choose Add Ater OML. A dialog box is displayed, as shown in Figure 6-8.

HUAWEI BSC6000 Base ControllerBSC Initial Configuration Guide 6 Configuring BSC Links

Issue 01 (2007-09-05) Huawei Technologies Proprietary 6-7

Figure 6-8 Configuring the Ater OML

Step 3 Click Add. A dialog box is displayed, as shown in Figure 6-9.

Figure 6-9 Adding an Ater OML

6 Configuring BSC LinksHUAWEI BSC6000 Base Controller

BSC Initial Configuration Guide

6-8 Huawei Technologies Proprietary Issue 01 (2007-09-05)

NOTE

l When the total number of the GMPS and GEPS is not greater than two, TS1 and 16 successive timeslotsmust be configured.

l When the total number of the GMPS and GEPS exceeds two, 31 timeslots from TS1 to TS31 must beconfigured.

Step 4 Set the parameters according to the data listed in Table 6-3.

Step 5 Click OK.

Step 6 Click Finish. The configuration is complete.

----End

6.1.3 Adding an Ater Signaling LinkWhen the GTCS is configured on the MSC side, the Ater connection path between the GMPSor GEPS and the GTCS must be configured with an Ater signaling link. The Ater signaling linktransmits the signaling of service control, TC resource management, and Ater transmissionresource management.

Scenario BSC initial configuration

Mandatory/Optional

Optional. When the GTCS is configured on the MSC side, the Ater signaling linkmust be configured.

NOTE

l The rate of an Ater signaling link can be 64 kbit/s or 2 Mbit/s, but only one rate type can be selected.

l Each GEIUT/GOIUT in the GTCS can be configured with up to sixteen 64 kbit/s Ater signaling links.

l Each GEIUT/GOIUT in the GTCS can be configured with up to eight 2 Mbit/s Ater signaling links.The maximum bandwidth is 4 Mbit/s.

l The rate of the Ater signaling link on the Ater interface must be the same as that of the SS7 signalinglink on the A interface.

l A total number of eight 2 Mbit/s signaling links and 2 Mbit/s SS7 signaling links can be configuredfor the GMPS or GEPS where the Ater connection path is located.

Prerequisitel The GTCS is configured on the MSC side.

l The Ater connection path between the GMPS or GEPS and the GTCS is configured.

l The GMPS or the GEPS is configured with the GXPUM.

PreparationNOTE

l This part describes how to configure the 64 kbit/s Ater signaling link.

l For details about the configuration of the 2 Mbit/s signaling link, refer to 高速信令.

HUAWEI BSC6000 Base ControllerBSC Initial Configuration Guide 6 Configuring BSC Links

Issue 01 (2007-09-05) Huawei Technologies Proprietary 6-9

Table 6-4 Example of data to be negotiated and planned for adding an Ater signaling link

Parameter Example Source

Ater Connection PathIndex

0 BSC internal planning

BM Subrack No. of AterConnection Path

0 BSC internal planning

Rate Type 64 kbit/s Negotiation with the peer

Satellite Flag No BSC internal planning

Timeslot Mask TS18 BSC internal planning

Procedure

Step 1 On the BSC6000 Local Maintenance Terminal, right-click a GEIUT in the GTCS. A shortcutmenu is displayed, as shown in Figure 6-10.

Figure 6-10 GEIUT shortcut menu

NOTE

The configuration of the Ater signaling link can be started only on the GEIUT/GOIUT in the GTCS.

Step 2 Choose Add Ater Signaling Link. A dialog box is displayed, as shown in Figure 6-11.

6 Configuring BSC LinksHUAWEI BSC6000 Base Controller

BSC Initial Configuration Guide

6-10 Huawei Technologies Proprietary Issue 01 (2007-09-05)

Figure 6-11 Configuring the Ater signaling link

Step 3 Click Add. A dialog box is displayed, as shown in Figure 6-12.

Figure 6-12 Adding an Ater signaling link

NOTE

Only one timeslot can be configured for the added 64 kbit/s Ater signaling link.

HUAWEI BSC6000 Base ControllerBSC Initial Configuration Guide 6 Configuring BSC Links

Issue 01 (2007-09-05) Huawei Technologies Proprietary 6-11

Step 4 Set the parameters according to the data listed in Table 6-4.

Step 5 Click OK.

Step 6 Click Finish. The configuration is complete.

----End

6.2 Configuring Links on the A InterfaceThis topic describes how to configure E1 connections and SS7 signaling links on the A interfacefor the communication between the BSC and the MSC.

1. 6.2.1 Adding an A Interface E1This topic describes how to configure the E1 connection on the A interface to establish thepath between the BSC and the MSC.

2. 6.2.2 Adding an SS7 Signaling LinkThis topic describes how to configure the SS7 signaling link on the A interface for thesignaling transmission between the BSC and the MSC.

6.2.1 Adding an A Interface E1This topic describes how to configure the E1 connection on the A interface to establish the pathbetween the BSC and the MSC.

Scenario BSC initial configuration

Mandatory/Optional

Mandatory

PrerequisiteThe GEIUA/GOIUA in the GTCS is configured.

Preparation

Table 6-5 Example of data to be negotiated and planned for configuring an A interface E1

Parameter Example Source

Subrack No. 3 BSC internal planning

Slot No. 20 BSC internal planning

Port No. 0 Negotiation with the peer

Start CIC 0 Negotiation with the peer

Procedure

Step 1 On the BSC6000 Local Maintenance Terminal, right-click a GEIUA in the GTCS. A shortcutmenu is displayed, as shown in Figure 6-13.

6 Configuring BSC LinksHUAWEI BSC6000 Base Controller

BSC Initial Configuration Guide

6-12 Huawei Technologies Proprietary Issue 01 (2007-09-05)

Figure 6-13 GEIUA shortcut menu

NOTE

The configuration of the A interface E1 can be started only on the GEIUA/GOIUA in the GTCS.

Step 2 Choose Configure A Interface E1. A dialog box is displayed, as shown in Figure 6-14.

Figure 6-14 Configuring an A interface E1

Step 3 Click Add. A dialog box is displayed, as shown in Figure 6-15. The default tab page is AInterface E1 Attributes.

HUAWEI BSC6000 Base ControllerBSC Initial Configuration Guide 6 Configuring BSC Links

Issue 01 (2007-09-05) Huawei Technologies Proprietary 6-13

Figure 6-15 Adding an A interface E1

Step 4 Set the parameters according to the data listed in Table 6-5.

NOTE

On the CIC Attributes tab page, retain the default settings or modify them according to your requirements.

Step 5 Click OK.

Step 6 Click Finish. The configuration is complete.

Step 7 Repeat Step 1 through Step 6 to add more E1 connections on the A interface.

----End

6.2.2 Adding an SS7 Signaling LinkThis topic describes how to configure the SS7 signaling link on the A interface for the signalingtransmission between the BSC and the MSC.

Scenario BSC initial configuration

Mandatory/Optional

Mandatory

NOTE

l Each GEIUT/GOIUT in the GTCS can be configured with up to sixteen 64 kbit/s SS7 signaling links.

l Each GEIUT/GOIUT in the GTCS can be configured with up to eight 2 Mbit/s SS7 signaling links.The maximum bandwidth is 4 Mbit/s.

l The rate of the SS7 signaling link must be the same as that of the Ater signaling link.

l A total number of eight 2 Mbit/s Ater signaling links and 2 Mbit/s SS7 signaling links can be configuredfor the GMPS or GEPS where the Ater connection path is located.

l Huawei recommends that all the 2 Mbit/s SS7 signaling links have the same number of timeslots toachieve the optimal load sharing effect.

6 Configuring BSC LinksHUAWEI BSC6000 Base Controller

BSC Initial Configuration Guide

6-14 Huawei Technologies Proprietary Issue 01 (2007-09-05)

Prerequisitel The SS7 DSP is configured.

l The GXPUM is configured in the GMPS or GEPS that connects with the GTCS. The Aterconnection path is configured.

l The A interface E1 is configured.

PreparationNOTE

l This part describes how to configure the 64 kbit/s SS7 signaling link.

l For details about the configuration of the 2 Mbit/s signaling link, refer to 高速信令.

Table 6-6 Example of data to be negotiated and planned for adding an SS7 signaling link

Parameter Example Source

Ater Connection PathIndex

1 BSC internal planning

BM Subrack No. of AterConnection Path

0 BSC internal planning

Rate Type 64 kbit/s Negotiation with the peer

A Subrack No. 3 BSC internal planning

A Slot No. 21 BSC internal planning

A Port No. 0 Negotiation with the peer

Ater Timeslot Mask TS10 BSC internal planning

A Timeslot Mask TS1 Negotiation with the peer

SLC 1 Negotiation with the peer

SLC Send 1 Negotiation with the peer

Procedure

Step 1 On the BSC6000 Local Maintenance Terminal, right-click a GEIUA in the GTCS. A shortcutmenu is displayed, as shown in Figure 6-16.

Figure 6-16 GEIUA shortcut menu

HUAWEI BSC6000 Base ControllerBSC Initial Configuration Guide 6 Configuring BSC Links

Issue 01 (2007-09-05) Huawei Technologies Proprietary 6-15

NOTE

The configuration of the SS7 signaling link can be started only on the GEIUA/GOIUA in the GTCS.

Step 2 Choose Configure SS7 Signaling Link. A dialog box is displayed, as shown in Figure 6-17.

Figure 6-17 Configuring the SS7 signaling link

Step 3 Click Add. A dialog box is displayed, as shown in Figure 6-18. The default tab page isMTP2.

6 Configuring BSC LinksHUAWEI BSC6000 Base Controller

BSC Initial Configuration Guide

6-16 Huawei Technologies Proprietary Issue 01 (2007-09-05)

Figure 6-18 Adding an SS7 signaling link (MTP2)

Step 4 Set the parameters according to the data listed in Table 6-6.

NOTE

The number of timeslots on the A interface must be the same as that on the Ater interface.

Step 5 Click the MTP3 tab, as shown in Figure 6-19.

HUAWEI BSC6000 Base ControllerBSC Initial Configuration Guide 6 Configuring BSC Links

Issue 01 (2007-09-05) Huawei Technologies Proprietary 6-17

Figure 6-19 Adding an SS7 signaling link (MTP3)

Step 6 Set the parameters according to the data listed in Table 6-6.

Step 7 Click OK.

Step 8 Click Finish. The configuration is complete.

----End

6.3 Configuring Links on the Pb InterfaceThis topic describes how to add a PCU and configure E1 connections and signaling links on thePb interface for the communication between the BSC and the PCU.

1. 6.3.1 Adding a PCUThis topic describes how to add a PCU for the BSC to process PS services.

2. 6.3.2 Configuring a Pb Interface E1This topic describes how to configure the E1 connection on the Pb interface to establishthe physical path between the BSC and the PCU.

3. 6.3.3 Configuring a Pb Signaling LinkThis topic describes how to configure a signaling link on the Pb interface for the signalingtransmission of the control of the PS service process between the BSC and the PCU andfor the signaling transmission of the Pb transmission resource management.

6 Configuring BSC LinksHUAWEI BSC6000 Base Controller

BSC Initial Configuration Guide

6-18 Huawei Technologies Proprietary Issue 01 (2007-09-05)

6.3.1 Adding a PCUThis topic describes how to add a PCU for the BSC to process PS services.

Scenario BSC initial configuration

Mandatory/Optional

Optional. The PCU should be configured when the BSC offers PS services.

NOTE

l A maximum of 32 PCUs can be configured for the BSC.

l The name and number of each PCU must be unique.

PrerequisiteNone.

Preparation

Table 6-7 Example of data to be negotiated and planned for adding a PCU

Parameter Example Source

PCU No. 1 BSC internal planning

PCU Name PCU 1 BSC internal planning

Procedure

Step 1 On the BSC6000 Local Maintenance Terminal, right-click BSC6000. A shortcut menu isdisplayed, as shown in Figure 6-20.

Figure 6-20 Shortcut menu in the management tree

Step 2 Choose Configure PCU. A dialog box is displayed, as shown in Figure 6-21.

HUAWEI BSC6000 Base ControllerBSC Initial Configuration Guide 6 Configuring BSC Links

Issue 01 (2007-09-05) Huawei Technologies Proprietary 6-19

Figure 6-21 Configuring the PCU

Step 3 Click Add. A dialog box is displayed, as shown in Figure 6-22.

Figure 6-22 Adding a PCU

Step 4 Set the parameters according to the data listed in Table 6-7.

Step 5 Click OK.

Step 6 Repeat Step 1 through Step 5 to add more PCUs.

6 Configuring BSC LinksHUAWEI BSC6000 Base Controller

BSC Initial Configuration Guide

6-20 Huawei Technologies Proprietary Issue 01 (2007-09-05)

Step 7 Click Finish. The configuration is complete.

----End

6.3.2 Configuring a Pb Interface E1This topic describes how to configure the E1 connection on the Pb interface to establish thephysical path between the BSC and the PCU.

Scenario BSC initial configuration

Mandatory/Optional

Optional. A Pb interface E1 should be configured when the BSC is configuredwith a PCU.

Prerequisitel The PCU is configured.

l The GEIUP/GOIUP is configured.

Preparation

Table 6-8 Example of data to be negotiated and planned for configuring a Pb interface E1

Parameter Example Source

Subrack No. 0 BSC internal planning

Slot No. 23 BSC internal planning

Port No. 0 Negotiation with the peer

Transfer Mode Terrestrial Transmission Negotiation with the peer

Start PCIC 0 BSC internal planning

PCU No. 1 BSC internal planning

Procedure

Step 1 On the BSC6000 Local Maintenance Terminal, right-click a GEIUP in the GMPS. A shortcutmenu is displayed, as shown in Figure 6-23.

Figure 6-23 GEIUP shortcut menu

HUAWEI BSC6000 Base ControllerBSC Initial Configuration Guide 6 Configuring BSC Links

Issue 01 (2007-09-05) Huawei Technologies Proprietary 6-21

NOTE

The configuration of the Pb interface E1 can be started only on the GEIUP/GOIUP in the GMPS or GEPS.

Step 2 Choose Configure Pb Interface E1. A dialog box is displayed, as shown in Figure 6-24.

Figure 6-24 Configuring a Pb interface E1

Step 3 Click Add. A dialog box is displayed, as shown in Figure 6-25. The default tab page is PbInterface E1 Attributes.

6 Configuring BSC LinksHUAWEI BSC6000 Base Controller

BSC Initial Configuration Guide

6-22 Huawei Technologies Proprietary Issue 01 (2007-09-05)

Figure 6-25 Adding a Pb interface E1

Step 4 Set the parameters according to the data listed in Table 6-8.

NOTE

On the CIC Attributes tab page, retain the default settings or modify them according to your requirements.

Step 5 Click OK.

Step 6 Click Finish. The configuration is complete.

----End

6.3.3 Configuring a Pb Signaling LinkThis topic describes how to configure a signaling link on the Pb interface for the signalingtransmission of the control of the PS service process between the BSC and the PCU and for thesignaling transmission of the Pb transmission resource management.

Scenario BSC initial configuration

Mandatory/Optional

Optional. A Pb signaling link should be configured when the BSC is configuredwith a PCU.

NOTE

Each GMPS or GEPS can be configured with up to 64 Pb signaling links.

PrerequisiteThe Pb interface E1 is configured.

HUAWEI BSC6000 Base ControllerBSC Initial Configuration Guide 6 Configuring BSC Links

Issue 01 (2007-09-05) Huawei Technologies Proprietary 6-23

Preparation

Table 6-9 Example of data to be negotiated and planned for configuring a Pb signaling link

Parameter Example Source

Port No. 0 Negotiation with the peer

Timeslot No. 1 Negotiation with the peer

Procedure

Step 1 On the BSC6000 Local Maintenance Terminal, right-click a GEIUP in the GMPS. A shortcutmenu is displayed, as shown in Figure 6-26.

Figure 6-26 GEIUP shortcut menu

NOTE

The configuration of a Pb signaling link can be started only on the GEIUP/GOIUP in the GMPS or GEPS.

Step 2 Choose Configure Pb Signaling Link. A dialog box is displayed, as shown in Figure 6-27.

6 Configuring BSC LinksHUAWEI BSC6000 Base Controller

BSC Initial Configuration Guide

6-24 Huawei Technologies Proprietary Issue 01 (2007-09-05)

Figure 6-27 Configuring a Pb signaling link

Step 3 Click Add. A dialog box is displayed, as shown in Figure 6-28.

Figure 6-28 Adding a Pb signaling link

Step 4 Set the parameters according to the data listed in Table 6-9.

Step 5 Click OK.

HUAWEI BSC6000 Base ControllerBSC Initial Configuration Guide 6 Configuring BSC Links

Issue 01 (2007-09-05) Huawei Technologies Proprietary 6-25

Step 6 Click Finish. The configuration is complete.

----End

6 Configuring BSC LinksHUAWEI BSC6000 Base Controller

BSC Initial Configuration Guide

6-26 Huawei Technologies Proprietary Issue 01 (2007-09-05)