2 BTS3006C CabinetAbout This Chapter
This topic describes the BTS3006C cabinet. A BTS3006C cabinet consists of the DMCM,
DBMB, DDRM, DPSM, DDCM, DDPM, DSCM, DATM, and fan box. The BTS3006C has a
modular structure and processes the BTS signals.
2.1 Appearance of a BTS3006C Cabinet
This topic shows the appearance of a BTS3006C cabinet. A BTS3006C cabinet is silver gray.
2.2 Physical Structure of the BTS3006C
This topic describes the BTS3006C physical structure, which consists of the BTS3006C cabinet,
antenna subsystem, and site maintenance equipment.
2.3 Cabling Holes of a BTS3006C Cabinet
This topic describes the cabling holes of a BTS3006C cabinet. All the external cables of a
BTS3006C cabinet are led into or led out of the cabinet through the waterproof module at the
bottom of the cabinet.
2.4 Cabling in the Front of a BTS3006C Cabinet
This topic describes the cabling in the front of a BTS3006C cabinet. The cables in the front of
a BTS3006C cabinet consist of the RF cables, the signal cables, and the power cables.
2.5 Cabling at the Rear of a BTS3006C Cabinet
This topic describes the cabling at the rear of a BTS3006C cabinet. There is only one yellow
and green PGND cable at the rear of a cabinet. The cable is connected to the external grounding
bar.
2.6 Engineering Specifications for the BTS3006C
This topic describes the engineering specifications for the BTS3006C. The BTS3006C
engineering specifications consist of the dimensions, weight, power, and power consumption.
iSite BTS3006C
Hardware Description 2 BTS3006C Cabinet
Issue 01 (2007-08-10) Huawei Technologies Proprietary 2-1
7/28/2019 01-02 BTS3006C Cabinet
2/8
2.1 Appearance of a BTS3006C Cabinet
This topic shows the appearance of a BTS3006C cabinet. A BTS3006C cabinet is silver gray.
Figure 2-1 shows a BTS3006C cabinet.
Figure 2-1 Appearance of a BTS3006C cabinet
2.2 Physical Structure of the BTS3006C
This topic describes the BTS3006C physical structure, which consists of the BTS3006C cabinet,
antenna subsystem, and site maintenance equipment.
Physical Structure of the BTS3006C Cabinet
Physically, the BTS3006C cabinet consists of the DDRM slots, DAFM slots, DPSM/DSEM
slot, DMCM slot, and fan subrack. Figure 2-2 shows the BTS3006C in full configuration.
2 BTS3006C Cabinet
iSite BTS3006C
Hardware Description
2-2 Huawei Technologies Proprietary Issue 01 (2007-08-10)
7/28/2019 01-02 BTS3006C Cabinet
3/8
Figure 2-2 Slots of the BTS3006C cabinet
DDRM2
DAFM 3
DAFM 2 DAFM 0
DDRM1 DDRM0
DSEM
DMCM
FAN 2 FAN 1 FAN 0 1
2
3
4
5
(1) Fan subrack (2) DMCM slot (3) DDRM slot
(4) DPSM/DSEM slot (5) DDRM slot
The modules that can be configured in these slots are as follows:
l DMCM slot: DMCM
l DDRM slot: DDRM
l DPSM/DSEM slot: DSEM orDPSM
l Fan subrack: Fan module.
l The DAFM slots can be configured with the following modules:
DDPM (mandatory)
DATM (optional)
DDCM (optional)
DSCM (optional)
Physical Structure of the Antenna Subsystem
For details of the antenna subsystem, refer to Antenna Subsystem of the BTS.
Physical Structure of the Site Maintenance Equipment
For details of the site maintenance equipment, refer to OM of the BTS.
iSite BTS3006C
Hardware Description 2 BTS3006C Cabinet
Issue 01 (2007-08-10) Huawei Technologies Proprietary 2-3
http://-/?-http://-/?-http://01-04%20bts3006c%20modules.pdf/http://01-04%20bts3006c%20modules.pdf/http://01-04%20bts3006c%20modules.pdf/http://01-04%20bts3006c%20modules.pdf/http://01-04%20bts3006c%20modules.pdf/http://01-04%20bts3006c%20modules.pdf/http://01-04%20bts3006c%20modules.pdf/http://01-04%20bts3006c%20modules.pdf/http://01-04%20bts3006c%20modules.pdf/7/28/2019 01-02 BTS3006C Cabinet
4/8
2.3 Cabling Holes of a BTS3006C Cabinet
This topic describes the cabling holes of a BTS3006C cabinet. All the external cables of a
BTS3006C cabinet are led into or led out of the cabinet through the waterproof module at the
bottom of the cabinet.
Figure 2-3 shows the bottom view of the cabling holes at the bottom of a BTS3006C cabinet.
Figure 2-3 Cabling holes at the bottom of a BTS3006C cabinet
E1_0/1
E1_2/3
ALM
OPT
7
1 2
3
4
5
6
Cabinet front door
(1) Waterproof module (2) Base of the door status switch (3) E1 cable (0, 1) (4) E1 cable (2, 3)
(5) External alarm cable (6) SDH external optical cable (7) Fan
The functions of the major components on the bottom plate of a BTS3006C cabinet are as
follows:
l Waterproof module: It supplies the reliable waterproof performance for the BTS3006C.
l Base of the door status switch: It is used to fasten the door status switch. A door status
alarm is reported in time through the door status cables.
NOTE
Actually, the base of the door status switch is not visible. Therefore, it is indicated with broken lines.
l
Fan: One DDRM module is configured with one fan unit. Fans are used to dissipate thesystem.
2 BTS3006C Cabinet
iSite BTS3006C
Hardware Description
2-4 Huawei Technologies Proprietary Issue 01 (2007-08-10)
7/28/2019 01-02 BTS3006C Cabinet
5/8
2.4 Cabling in the Front of a BTS3006C Cabinet
This topic describes the cabling in the front of a BTS3006C cabinet. The cables in the front of
a BTS3006C cabinet consist of the RF cables, the signal cables, and the power cables.
Cabling in the Front of a Cabinet
Figure 2-4 shows the cabling in the front of a BTS3006C cabinet.
Figure 2-4 Cabling in the front of a BTS3006C cabinet
NOTE
The cabling shown in Figure 2-4 is based on S2/2/2 configuration that has TMA power supply.
Cabling in the Front of a Cabinet
Table 2-1 lists the cables in the front of a cabinet.
iSite BTS3006C
Hardware Description 2 BTS3006C Cabinet
Issue 01 (2007-08-10) Huawei Technologies Proprietary 2-5
7/28/2019 01-02 BTS3006C Cabinet
6/8
Table 2-1 Cabling in the front of a cabinet
CableNo.
Cable Quantity
1 BTS3006C RF Signal Cables 6
2 1/4-inch RF jumper 6
3 BTS3006C RF Signal Cables 6
4 TMA Power Supply Cables 6
5 Fan power unit 3
6 door status signal cable of a cabinet 1
7 DC power cable 2
2.5 Cabling at the Rear of a BTS3006C Cabinet
This topic describes the cabling at the rear of a BTS3006C cabinet. There is only one yellow
and green PGND cable at the rear of a cabinet. The cable is connected to the external grounding
bar.
For the method of connecting the PGND cable, refer to 5.2.4 BTS3006C/BTS3002E PGND
Cables.
2.6 Engineering Specifications for the BTS3006CThis topic describes the engineering specifications for the BTS3006C. The BTS3006C
engineering specifications consist of the dimensions, weight, power, and power consumption.
Dimensions
Table 2-2 lists the dimensions of a BTS3006C cabinet.
Table 2-2 Dimensions of a BTS3006C cabinet
BTS3006C Width (mm) Depth (mm) Height (mm)
Cabinet 600 470 700
Table 2-3 lists the dimensions of a BTS3006C cabinet base.
Table 2-3 Dimensions of a BTS3006C cabinet base
BTS3006C Width (mm) Depth (mm) Height (mm)
Base 600 470 200
Table 2-4 shows the dimensions of a rainhat.
2 BTS3006C Cabinet
iSite BTS3006C
Hardware Description
2-6 Huawei Technologies Proprietary Issue 01 (2007-08-10)
http://01-05%20bts3006c%20cables.pdf/http://01-05%20bts3006c%20cables.pdf/http://01-05%20bts3006c%20cables.pdf/http://01-05%20bts3006c%20cables.pdf/http://01-05%20bts3006c%20cables.pdf/http://01-05%20bts3006c%20cables.pdf/http://01-05%20bts3006c%20cables.pdf/http://01-05%20bts3006c%20cables.pdf/http://01-05%20bts3006c%20cables.pdf/http://01-05%20bts3006c%20cables.pdf/http://01-05%20bts3006c%20cables.pdf/7/28/2019 01-02 BTS3006C Cabinet
7/8
Table 2-4 Dimensions of a rainhat
BTS3006C Width (mm) Depth (mm) Height (mm)
Rainhat 600 470 80
Weight
Table 2-5 lists the weight of a BTS3006C cabinet.
Table 2-5 Weight of a BTS3006C cabinet
Configuration Type Weight (kg)
Empty cabinet 35
Full configuration (S2/2/2configuration that has TMA power
supply)
130
Table 2-6 lists the weight of a BTS3006C cabinet base.
Table 2-6 Weight of a BTS3006C cabinet base
BTS3006C Weight (kg)
Base 13
Table 2-7 shows the weight of a rainhat.
Table 2-7 Weight of a rainhat
BTS3006C Weight (kg)
Rainhat 2
Power Supply
The BTS3006C DC input power complies with the power requirements of the ETS 300 132-2.
Table 2-8 lists the specifications of the DC input power.
Table 2-8 Specifications of the DC input power
Parameter Value
Nominal value 48 V DC
Allowed Range 40 V DC to 60 V DC
Table 2-9 lists the specifications of the BTS3006C AC input power.
iSite BTS3006C
Hardware Description 2 BTS3006C Cabinet
Issue 01 (2007-08-10) Huawei Technologies Proprietary 2-7
7/28/2019 01-02 BTS3006C Cabinet
8/8
Table 2-9 Specifications of the AC input power
Power Distribution Type Allowed Range
110 V AC dual-live input 85 V AC135 V AC, 45 Hz65 Hz
220 AC single-live input 150 V AC300 V AC, 45 Hz65 Hz
NOTE
l 110 V AC input requires the support of the dual-live input.
l In indoor application, Sidepower can be used to input +24 V DC power.
Power Consumption
Table 2-10 lists the power consumption of the BTS3006C in full configuration.
Table 2-10 BTS3006C DC power consumption
PowerConsumption
850 MHz 900 MHz 1800 MHz 1900 MHz
Typical value 1.1 kW 1.1 kW 1.2 kW 1.2 kW
Maximum value
(The heating
board is
operational.)
1.8 kW 1.8 kW 1.8 kW 1.8 kW
Maximum value(The heating
board is out-of-
work.)
1.6 kW 1.6 kW 1.6 kW 1.6 kW
2 BTS3006C Cabinet
iSite BTS3006C
Hardware Description
2-8 Huawei Technologies Proprietary Issue 01 (2007-08-10)