01-05 BTS3006C Cables

Embed Size (px)

Citation preview

  • 7/28/2019 01-05 BTS3006C Cables

    1/25

    5 BTS3006C CablesAbout This Chapter

    This topic describes the functions, appearance, assignment of pins, and installation positions of

    the BTS3006C cables.

    5.1 BTS3006C Cable List

    This topic describes the BTS3006C cable list. The BTS3006C cables are classified into the power

    cables, PGND cable, transmission cables, signal cables, RF cables, and cables between the

    BTS3006C and the auxiliary equipment.

    5.2 BTS3006C Power Cables and PGND Cables

    This topic describes the BTS3006C power cables and PGND cables. The BTS3006C power

    cables consist of the AC power cables, DC power cables, TMA power cables, and fan power

    cables. The grounding cables consist of the PGND cables in the transmission interface box, the

    PGND cables in the power interface box, and the external input PGND cables.

    5.3 BTS3006C Transmission Cables

    This topic describes the BTS3006C transmission cables. The BTS3006C transmission cables

    consist of the E1 cables, cabinet-group optical fibers, and SDH external optical cables.

    5.4 BTS3006C Signal Cables

    This topic describes the BTS3006C signal cables. The BTS3006C signal cables consist of the

    BTS3006C door status signal cables and BTS3006C external alarm cables.

    5.5 BTS3006C RF Cables

    This topic describes the BTS3006C RF cables. The BTS3006C RF cables consist of the

    BTS3006C RF signal cables and the BTS3006C 1/4-inch RF jumpers.

    5.6 Cables Between the BTS3006C and the Auxiliary Equipment

    This topic describes the cables between the BTS3006C and the auxiliary equipment. The cables

    between the BTS3006C and the auxiliary equipment consist of the signal cables in the external

    environment alarm box and the power cables between the Sidepower and the BTS3006C.

    iSite BTS3006C

    Hardware Description 5 BTS3006C Cables

    Issue 01 (2007-08-10) Huawei Technologies Proprietary 5-1

  • 7/28/2019 01-05 BTS3006C Cables

    2/25

    5.1 BTS3006C Cable List

    This topic describes the BTS3006C cable list. The BTS3006C cables are classified into the power

    cables, PGND cable, transmission cables, signal cables, RF cables, and cables between the

    BTS3006C and the auxiliary equipment.

    Table 5-1 lists the BTS3006C cables.

    Table 5-1 BTS3006C cable list

    Item Sub-Item Installation Position Remarks

    Power

    cables

    AC power

    cable

    One end connects to AC INPUT

    port on the DPSM.

    The other end connects to the

    output port of the externalintegral power system.

    Two ends of the cables are not

    connected and need to be

    installed on site. For the

    installation method, refer toInstalling the Power Cables

    Between the AFB and the

    BTS3006C/BTS3002E.

    DC power

    cable

    Blue: One end connects to NEG

    (-) wire post of the DSEM. The

    other end connects to the port of

    the external integral power

    system.

    Black: One end connects to

    NEG(+) wire post of the DSEM.

    The other end connects to theport of the external integral

    power system.

    Two ends of the cables are not

    connected and need to be

    installed on site. For the

    installation method, refer to

    Installing the Power Cables

    Between the APM and the

    BTS3006C/BTS3002E.

    Fan power

    unit

    One end connects to FAN port

    on the DDRM.

    The other end connects to the

    fan.

    One end of the cable is

    connected to the fan before

    delivery. The other end needs

    to be installed on site. For the

    installation method, refer to

    Installing the Power Cables

    for the Fans of the

    BTS3006C/BTS3002E.

    PGND

    cables

    External

    PGND cable

    One end connects to the

    grounding terminal at the rear of

    a cabinet.

    The other end connects to the

    external protection grounding

    busbar.

    Two ends of the cables are not

    connected and need to be

    installed on site. For the

    installation method, refer to

    Installing the PGND Cable

    of the BTS3006C/

    BTS3002E.

    5 BTS3006C Cables

    iSite BTS3006C

    Hardware Description

    5-2 Huawei Technologies Proprietary Issue 01 (2007-08-10)

    http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-
  • 7/28/2019 01-05 BTS3006C Cables

    3/25

    Item Sub-Item Installation Position Remarks

    PGND cable

    in the

    transmission

    interface box

    One end connects to any free

    wire clip on the grounding bar in

    the transmission interface box.

    The other end connects to the

    external protection grounding

    busbar.

    Two ends of the cables are not

    connected and need to be

    installed on site. For the

    installation method, refer to

    Installing the PGND Cable

    of the BTS3006C/

    BTS3002E.

    PGND cable

    in the power

    interface box

    One end connects to the

    grounding terminal in the

    interface box.

    The other end connects to the

    external protection grounding

    busbar.

    Two ends of the cables are not

    connected and need to be

    installed on site. For the

    installation method, refer to

    Installing the PGND Cable

    of the BTS3006C/

    BTS3002E.

    Transmis

    sion

    cables

    E1 cable One end connects to the E1_0/1

    port or E1_2/3 port at the bottom

    of the DMCM.

    The other end connects to the

    transmission equipment.

    Two ends of the cables are not

    connected and need to be

    installed on site. For the

    installation method, refer to

    Installing the E1 Cable of

    the BTS3006C/BTS3002E.

    Optical

    fibers for

    combined

    cabinets or

    cabinetgroups

    One end connects to the SFP-A

    port and SFP-B port on the

    DMCM in the main cabinet.

    The other end connects to the

    SFP-A port and the SFP-B port

    on the DMCM in the extension

    cabinet.

    Two ends of the cables are not

    connected and need to be

    installed on site. For the

    installation method, refer to

    Installing the BTS3006C/BTS3002E Optical Cable

    for Combined Cabinets or

    for Cabinet Groups.

    Optical cable One end connects to the OPT

    port on the DMCM in the main

    cabinet.

    The other end connects to the

    transmission equipment.

    Two ends of the cables are not

    connected and need to be

    installed on site. For the

    installation method, refer to

    Installing the Optical Cable

    of the BTS3006C/

    BTS3002E.

    Signal

    cables

    Door status

    signal cable

    of a cabinet

    One end connects to the DOOR

    port on the DMCM in the main

    cabinet.

    The other end connects to the

    door status switch at the bottom

    of a cabinet.

    One end of the cable is

    connected to the door status

    switch before delivery. The

    other end needs to be installed

    on site. For the installation

    method, refer to Installing

    the Door Control Cable of

    the BTS3006C/BTS3002E

    Cabinet.

    iSite BTS3006C

    Hardware Description 5 BTS3006C Cables

    Issue 01 (2007-08-10) Huawei Technologies Proprietary 5-3

    http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-
  • 7/28/2019 01-05 BTS3006C Cables

    4/25

    Item Sub-Item Installation Position Remarks

    RET control

    signal cable

    One end connects to any ANT

    port on the DATM panel.

    The other end connects to theSMA port on the Bias-Tee.

    Two ends of the cables are not

    connected and need to be

    installed on site. For the

    installation method, refer to

    Installing the RET Control

    Signal Cables of the

    BTS3006C/BTS3002E.

    External

    alarm cable

    One end connects to the ALM

    port on the DMCM in the main

    cabinet.

    The other end connects to the

    alarm port on the auxiliary

    equipment.

    Two ends of the cables are not

    connected and need to be

    installed on site. For the

    installation method, refer to

    Installing the Alarm Cable

    Between the APM and the

    BTS3006C/BTS3002E.

    RF cables 1/4-inch RF

    jumper

    One end connects to the antenna

    port ANTA or ANTB on the

    DDPM.

    The other end connects to the

    feeder of the antenna system

    when there is no power supply

    for the TMA. The other end

    connects to the Bias-Tee when

    there is power supply for the

    TMA.

    Two ends of the cables are not

    connected and need to be

    installed on site. For the

    installation method, refer to

    Installing the 1/4-Inch RF

    Jumpers of the BTS3006C/

    BTS3002E.

    RF signal

    cable

    RF signal cables are classified

    into the RF transmit and receive

    signal cables. The RF transmit

    signal cable connects to the TX

    port on the DDRM and the

    corresponding TX port on the

    DDPM/DDCM.

    The RF receive signal cable

    connects to the RX port on the

    DDRM and the corresponding

    RX port on the DDPM.

    Two ends of the cables are not

    connected and need to be

    installed on site. For the

    installation method, refer to

    Installing the RF Signal

    Cables of the BTS3006C/

    BTS3002E.

    5 BTS3006C Cables

    iSite BTS3006C

    Hardware Description

    5-4 Huawei Technologies Proprietary Issue 01 (2007-08-10)

    http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-
  • 7/28/2019 01-05 BTS3006C Cables

    5/25

    Item Sub-Item Installation Position Remarks

    Cables

    between

    the

    BTS3006

    C and the

    auxiliary

    equipme

    nt

    Signal cable

    in the

    external

    environment

    alarm box

    One end connects to the DB9

    (RS485) alarm port on the

    external environment alarm box.

    The other end connects to the

    bare wire end of the external

    alarm cable carried by the

    BTS3006C.

    Two ends of the cables are not

    connected and need to be

    installed on site. For the

    installation method, refer to

    Installing the Alarm Cable

    Between the EMUA and the

    BTS3006C/BTS3002E,

    Installing the Alarm Cable

    Between the EMU and the

    BTS3006C/BTS3002E, and

    Installing the Alarm Cable

    Between the EAC-2 and the

    BTS3006C/BTS3002E.

    5.2 BTS3006C Power Cables and PGND Cables

    This topic describes the BTS3006C power cables and PGND cables. The BTS3006C power

    cables consist of the AC power cables, DC power cables, TMA power cables, and fan power

    cables. The grounding cables consist of the PGND cables in the transmission interface box, the

    PGND cables in the power interface box, and the external input PGND cables.

    5.2.1 BTS3006C/BTS3002E AC Power Cables

    This topic describes the BTS3006C/BTS3002E AC power cables. The BTS3006C AC power

    cables are used to connect the power interface box and the DPSM. In addition, the BTS3006C

    AC power cables can be used to send the power interface box to the DPSM AC power modulethrough the 220 V AC and 110 V AC power.

    5.2.2 BTS3006C/BTS3002E DC Power Cables

    This topic describes the BTS3006C/BTS3002E DC power cables. The DC power cables are used

    to connect the power interface box and the DSEM. The DC power cables are used to supply

    power from the power interface box to the DSEM in a cabinet.

    5.2.3 BTS3006C/BTS3002E Fan Power Cables

    This topic describes the fan power cable of the BTS3006C/BTS3002E. The fan power cables

    are used to connect the DDRM and the fan so that power can be supplied to the fan. At the same

    time, the fan power cables are used to transmit the control signals of in-position detection of the

    fan, monitoring of the fan status, fan alarms, and speed adjustment.

    5.2.4 BTS3006C/BTS3002E PGND Cables

    This topic describes the BTS3006C/BTS3002E PGND cables. The BTS3006C/BTS3002E

    PGND cable has the following three types: the external input PGND cable, the PGND cable in

    the transmission interface box, and the PGND cable in the power interface box.

    5.2.5 Equipotential Cable of the BTS

    This part describes the function, structure, pin assignment, and installation positions of the

    equipotential cable.

    5.2.1 BTS3006C/BTS3002E AC Power Cables

    This topic describes the BTS3006C/BTS3002E AC power cables. The BTS3006C AC powercables are used to connect the power interface box and the DPSM. In addition, the BTS3006C

    iSite BTS3006C

    Hardware Description 5 BTS3006C Cables

    Issue 01 (2007-08-10) Huawei Technologies Proprietary 5-5

    http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-
  • 7/28/2019 01-05 BTS3006C Cables

    6/25

    AC power cables can be used to send the power interface box to the DPSM AC power module

    through the 220 V AC and 110 V AC power.

    Functions

    The BTS3006C AC power cables are used to connect the power interface box and the DPSM.

    In addition, the BTS3006C AC power cables can be used to send the power interface box to the

    DPSM AC power module through the 220 V AC and 110 V AC power.

    Appearance

    A DPSM AC power cable is 3 m long. Two ends of the power cable are bare wires. Two

    connectors are required to be made on site to match the bare wire ends, as shown in Figure

    5-1.

    Figure 5-1 AC power cable

    Pin Description

    Table 5-2 lists the pin assignment for the DPSM AC power cables.

    Table 5-2 Pin assignment for the DPSM AC power cables

    Pin Wire Color Remarks

    X.1 Brown L

    X.2 Green and

    yellow

    PGND

    X.3 Blue N

    Installation PositionTable 5-3 describes the installation positions of the AC power cables.

    5 BTS3006C Cables

    iSite BTS3006C

    Hardware Description

    5-6 Huawei Technologies Proprietary Issue 01 (2007-08-10)

  • 7/28/2019 01-05 BTS3006C Cables

    7/25

    Table 5-3 Installation position of an AC power cable

    Cable Name One End The Other End

    DPSM AC power

    cable

    Connects to port AC

    INPUT on the DPSMConnects to L wire post for

    the brown wire; connects

    to PE wire post for the

    yellow and green wire;

    connects to N wire post for

    the blue wire

    Connects to the output port of the external

    integral power system

    5.2.2 BTS3006C/BTS3002E DC Power Cables

    This topic describes the BTS3006C/BTS3002E DC power cables. The DC power cables are used

    to connect the power interface box and the DSEM. The DC power cables are used to supplypower from the power interface box to the DSEM in a cabinet.

    Functions

    The DC power cables are used to connect the power interface box and the DSEM. The DC power

    cables are used to supply power from the power interface box to the DSEM in a cabinet.

    Appearance

    There are two DC power cables. One is blue and the other is black. Two ends of the power cable

    are OT terminals. You can shorten the length of the power cable based on the actual situation.

    Figure 5-2 shows the DC power cables.

    Figure 5-2 DC power cable

    Pin Description

    None

    Installation Position

    Table 5-4 describes the installation positions of the DC power cables.

    iSite BTS3006C

    Hardware Description 5 BTS3006C Cables

    Issue 01 (2007-08-10) Huawei Technologies Proprietary 5-7

  • 7/28/2019 01-05 BTS3006C Cables

    8/25

    Table 5-4 Installation positions of the DC power cables

    Cable Name One End The Other End

    DSEM DC power

    cable (blue)

    Connects to NEG(-) wire

    post of the DSEM.

    Connects to the port on the external

    integral power system.

    DSEM DC power

    cable (black)

    Connects to NEG(+) wire

    post of the DSEM.

    Connects to the port on the external

    integral power system.

    5.2.3 BTS3006C/BTS3002E Fan Power Cables

    This topic describes the fan power cable of the BTS3006C/BTS3002E. The fan power cables

    are used to connect the DDRM and the fan so that power can be supplied to the fan. At the same

    time, the fan power cables are used to transmit the control signals of in-position detection of the

    fan, monitoring of the fan status, fan alarms, and speed adjustment.

    Functions

    The fan power cables are used to connect the DDRM and the fan so that power can be supplied

    to the fan. At the same time, the fan power cables are used to transmit the control signals of in-

    position detection of the fan, monitoring of the fan status, fan alarms, and speed adjustment.

    Appearance

    A fan power cable is 0.5 m long. One end of the cable is a round waterproof connector and the

    other end is connected to the fan before delivery. Figure 5-3 shows the fan cable.

    Figure 5-3 Fan power cable

    W

    X

    A

    View A

    Cylindrical

    waterproof connector

    1

    2

    3

    56

    78 4

    Pin Description

    Table 5-5 lists the pin assignment for the fan power cable.

    Table 5-5 Pin assignment for the fan power cable

    Wire Pins at the X End Wire Color

    W X.3 Black

    X.4 Black

    X.5 Red

    5 BTS3006C Cables

    iSite BTS3006C

    Hardware Description

    5-8 Huawei Technologies Proprietary Issue 01 (2007-08-10)

  • 7/28/2019 01-05 BTS3006C Cables

    9/25

    Wire Pins at the X End Wire Color

    X.6 Purple

    X.7 White

    X.8 Blue

    Installation Position

    Table 5-6 shows the arrangement of the fan power cables.

    Table 5-6 Installation position of a fan power cable

    Cable Name One End (RoundWaterproof Connector)

    The Other End

    Fan power cable Connects to FAN port on the

    DDRM.

    Connects to the fan fixedly.

    5.2.4 BTS3006C/BTS3002E PGND Cables

    This topic describes the BTS3006C/BTS3002E PGND cables. The BTS3006C/BTS3002E

    PGND cable has the following three types: the external input PGND cable, the PGND cable in

    the transmission interface box, and the PGND cable in the power interface box.

    Functions

    The PGND cables are used to ground the cabinets properly. The types of PGND cables are as

    follows:

    l The external PGND cables that are used to keep a cabinet well grounded.

    l The PGND cables in the transmission interface box that are used to keep this box well

    grounded.

    l The PGND cables in the power interface box are used to keep this box well grounded.

    Appearance

    A BTS3006C/BTS3002E PGND cable has a 25 mm2 cross-sectional area and is a yellow andgreen plastic insulation copper core cable. Two ends of a PGND cable are OT terminals (lugs).

    Two terminals of a PGND cable are required to be made on site. Figure 5-4 shows a PGND

    cable.

    Figure 5-4 BTS3006C/BTS3002E PGND cable

    Pin Description

    None

    iSite BTS3006C

    Hardware Description 5 BTS3006C Cables

    Issue 01 (2007-08-10) Huawei Technologies Proprietary 5-9

  • 7/28/2019 01-05 BTS3006C Cables

    10/25

    Installation Position

    Table 5-7 lists the installation positions of the BTS3006C/BTS3002E PGND cables.

    Table 5-7 Installation positions of the PGND cablesCable Name One End The Other End

    External PGND cable Connects to the grounding

    terminal at the rear of a cabinet.

    Connects to the external

    protection grounding

    busbar.PGND cable in the transmission

    interface box

    Connects to any free wire clip

    of the grounding bar in the

    transmission interface box.

    PGND cable in the power

    interface box

    Connects to the grounding

    terminal in the interface box.

    5.2.5 Equipotential Cable of the BTS

    This part describes the function, structure, pin assignment, and installation positions of the

    equipotential cable.

    Function

    The equipotential cable helps keep an equal potential between the cabinets and ensuring the safe

    operation of the BTSs.

    Structure

    The equipotential cable is a green and yellow cable with cross-sectional area of 25 mm2. Both

    ends of the cable use OT terminals. See Figure 5-5 for details.

    Figure 5-5 Structure of the equipotential cable

    Pin Assignment

    None.

    Installation Positions

    Table 5-8 describes the installation positions of the equipotential cable.

    5 BTS3006C Cables

    iSite BTS3006C

    Hardware Description

    5-10 Huawei Technologies Proprietary Issue 01 (2007-08-10)

  • 7/28/2019 01-05 BTS3006C Cables

    11/25

    Table 5-8 Installation positions of the equipotential cable

    Cabinet Model One End (OTTerminal)

    Other End (OT Terminal)

    BTS3012 Connects to the PGNDbar on top of one

    cabinet

    Connects to the PGND bar on top ofthe other cabinet

    BTS3012AE Connects to the PGND

    bar at the bottom of one

    cabinet

    Connects to the PGND bar at the

    bottom of the other cabinet

    BTS3006C Connects to the PGND

    bar at the back of one

    cabinet

    Connects to the PGND bar at the back

    of the other cabinet

    BTS3002E Connects to one

    external PGND bar

    Connects to the other external PGND

    bar

    5.3 BTS3006C Transmission CablesThis topic describes the BTS3006C transmission cables. The BTS3006C transmission cables

    consist of the E1 cables, cabinet-group optical fibers, and SDH external optical cables.

    5.3.1 BTS3006C/BTS3002E E1 Cables

    This topic describes the BT3006C/BTS3002E E1 cables. The BT3006C/BTS3002E E1 cables

    (75-ohm E1 cables and 120-ohm E1 cables) are used to transmit signals between the BTS and

    the BSC.5.3.2 Optical Fibers for the BTS3006C/BTS3002E Combined Cabinets or Cabinet Groups

    This topic describes the optical fibers for the BTS3006C/BTS3002E combined cabinets or

    cabinet groups. The optical fibers for the BTS3006C/BTS3002E combined cabinets or cabinet

    groups are used to achieve the optical combined cabinets or cabinet groups between cabinets.

    5.3.3 BTS3006C/BTS3002E SDH External Optical Cables

    This topic describes the BTS3006C/BTS3002E SDH external optical cables. The BTS3006C/

    BTS3002E SDH external optical cables are used to transmit optical signals so that the optical

    connection between the cabinet and other equipment can be established.

    5.3.1 BTS3006C/BTS3002E E1 Cables

    This topic describes the BT3006C/BTS3002E E1 cables. The BT3006C/BTS3002E E1 cables

    (75-ohm E1 cables and 120-ohm E1 cables) are used to transmit signals between the BTS and

    the BSC.

    Functions

    The BT3006C E1 cables (75-ohm E1 cables and 120-ohm E1 cables) are used to transmit signals

    between the BTS and the BSC.

    Appearance

    A 75-ohm E1 cable is a 3 m-long coaxial cable. It consists of four mini coaxial cables. Two ofthem form one E1 path. Therefore, each 75-ohm E1 cable can provide two E1 paths. 75 ohms

    iSite BTS3006C

    Hardware Description 5 BTS3006C Cables

    Issue 01 (2007-08-10) Huawei Technologies Proprietary 5-11

  • 7/28/2019 01-05 BTS3006C Cables

    12/25

    One end of a 75-ohm E1 cable is a round waterproof connector and the other end is an SMB

    terminal. Figure 5-6 shows a 75-ohm E1 cable.

    Figure 5-6 75-ohm E1 cable

    Cylindrical

    waterproof connector

    SMB connector

    X5

    WA

    View A

    W1

    W2

    W3

    W4

    X1

    X2

    X3

    X4

    TX0

    RX0

    TX1

    RX1

    1 23 45

    786

    A 120-ohm E1 cable is a 3 m-long twisted pair cable. It consists of four twisted pair cables. Two

    of them form one E1 path. Therefore, each 120-ohm E1 cable can provide two E1 paths. One

    end of a 120-ohm E1 cable is a round waterproof connector, and the other end is a bare wire.

    The bare wire end is selected and made on site based on the actual situation. 120 ohms Figure

    5-7 shows a E1 cable.

    Figure 5-7 120-ohm E1 cable

    Cylindrical

    Waterproof connector

    WA

    View A

    1 23 45

    786

    X1

    Pin Description

    Table 5-9 and Table 5-10 separately describe the pin assignment for the 75-ohm E1 cables and

    the 120-ohm E1 cables.

    Table 5-9 Pin assignment for the 75-ohm E1 cables

    Wire Coaxial CableWire/Outer

    Conductor

    Pins at X5 EndRound Waterproof

    Connector

    Coaxial Cable Label

    W1 X1.tip X5.1 TX0

    X1.ring X5.2

    W2 X2.tip X5.3 RX0

    X2.ring X5.4

    W3 X3.tip X5.5 TX1

    X3.ring X5.6

    W4 X4.tip X5.7 RX1

    5 BTS3006C Cables

    iSite BTS3006C

    Hardware Description

    5-12 Huawei Technologies Proprietary Issue 01 (2007-08-10)

  • 7/28/2019 01-05 BTS3006C Cables

    13/25

    Wire Coaxial CableWire/OuterConductor

    Pins at X5 EndRound WaterproofConnector

    Coaxial Cable Label

    X4.ring X5.8

    Table 5-10 Pin assignment for the 120-ohm E1 cables

    Wire Pins at X1 EndRound WaterproofConnector

    Wire Color Remarks on TwistedPair Cable

    W X1.1 White TT0

    X1.2 Blue TR0

    X1.3 White RT0

    X1.4 Orange RR0

    X1.5 White TT1

    X1.6 Green TR1

    X1.7 White RT1

    X1.8 Brown RR1

    Installation Position

    The installation modes of the 75-ohm E1 cables and 120-ohm E1 cables are the same. The

    installation methods of cables are determined based on the cabinet installation modes.

    l If a BTS3006C cabinet is installed on the ground, you need to lead cables from the right

    cabling hole at the bottom of the base into the bottom of the DMCM in the cabinet.

    l If a BTS3002E cabinet is installed on a wall, you need to connect cables directly to the

    bottom of the DMCM in the cabinet.

    l If a BTS3006C/BTS3002E cabinet is installed on a pole, you need to connect cables directly

    to the bottom of the DMCM in the cabinet.

    Table 5-11 lists the installation positions of a 75-ohm E1 cable and a 120-ohm E1 cable.

    Table 5-11 Installation positions of the E1 cables

    Cable Name One End The Other End

    75-ohm E1 cable A round waterproof connector:

    connects to E1_0/1 port or E1_2/3

    port at the bottom of the DMCM

    SMB terminal: connects to the

    transmission equipment, such as

    the transmission interface box

    120-ohm E1 cable A round waterproof connector:

    connects to E1_0/1 port or E1_2/3

    port at the bottom of the DMCM

    Bare wire: connects to the

    transmission equipment, such as

    the transmission interface box

    iSite BTS3006C

    Hardware Description 5 BTS3006C Cables

    Issue 01 (2007-08-10) Huawei Technologies Proprietary 5-13

  • 7/28/2019 01-05 BTS3006C Cables

    14/25

    5.3.2 Optical Fibers for the BTS3006C/BTS3002E CombinedCabinets or Cabinet Groups

    This topic describes the optical fibers for the BTS3006C/BTS3002E combined cabinets or

    cabinet groups. The optical fibers for the BTS3006C/BTS3002E combined cabinets or cabinet

    groups are used to achieve the optical combined cabinets or cabinet groups between cabinets.

    Functions

    The optical fibers for the BTS3006C/BTS3002E combined cabinets or cabinet groups are used

    to achieve the optical combined cabinets or cabinet groups between cabinets.

    Appearance

    Both ends of a optical fiber for the BTS3006C/BTS3002E combined cabinets and the cabinet

    group are LC optical connectors. Figure 5-8 shows the optical fiber.

    Figure 5-8 Optical fiber for combined cabinets or cabinet groups

    CAUTION

    An optical fiber connector must be covered with dustproof caps when it is not in use.

    Pin Description

    None

    Installation Position

    Table 5-12 lists the installation position of an optical fiber for the BTS3006C/BTS3002E

    combined cabinets and cabinet groups.

    Table 5-12 Installation position of an optical fiber for combined cabinets and cabinet groups

    Cable Type One End The Other End

    Optical fiber

    for combined

    cabinets or

    cabinet

    groups

    Connects to SFP-A port and

    SFP-B port on the DMCM in the

    main cabinet.

    Connects to SFP-A port and SFP-B port

    on the DMCM in the extension cabinet.

    5 BTS3006C Cables

    iSite BTS3006C

    Hardware Description

    5-14 Huawei Technologies Proprietary Issue 01 (2007-08-10)

  • 7/28/2019 01-05 BTS3006C Cables

    15/25

    5.3.3 BTS3006C/BTS3002E SDH External Optical Cables

    This topic describes the BTS3006C/BTS3002E SDH external optical cables. The BTS3006C/

    BTS3002E SDH external optical cables are used to transmit optical signals so that the optical

    connection between the cabinet and other equipment can be established.

    Functions

    The BTS3006C/BTS3002E SDH external optical cables are used to transmit optical signals so

    that the optical connection between the cabinet and other equipment can be established.

    Appearance

    A BTS3006C/BTS3002E SDH external optical cable is 3 m long. One end is round waterproof

    connector. The other end matches four FC optical connectors, as shown in Figure 5-9.

    Figure 5-9 SDH external optical cable

    Cylindrical

    waterproof connector FC connector

    X0

    WTX

    WRX

    ETX

    ERX

    X1

    X2

    X3

    X4

    2

    14

    3w

    Pin Description

    Table 5-13 lists the pin assignment for the BTS3006C/BTS3002E SDH external optical cables.

    Table 5-13 Pin assignment for the BTS3006C SDH external optical cables

    XO End X1X4 End X1X4 Wire Label

    X0.1 X1 WTX

    X0.2 X2 WRX

    X0.3 X3 ETX

    X0.4 X4 ERX

    Installation Position

    Table 5-14 lists the installation position of a BTS3006C/BTS3002E SDH external optical cable.

    iSite BTS3006C

    Hardware Description 5 BTS3006C Cables

    Issue 01 (2007-08-10) Huawei Technologies Proprietary 5-15

  • 7/28/2019 01-05 BTS3006C Cables

    16/25

    Table 5-14 Installation position of an SDH external optical cable

    Cable Name One End (RoundWaterproof Connector)

    The Other End (FC OpticalConnector)

    SDH externaloptical cable

    Connects to OPT port on theDMCM in the main cabinet.

    Connects to the transmission equipment(such as, the transmission interface box)

    5.4 BTS3006C Signal Cables

    This topic describes the BTS3006C signal cables. The BTS3006C signal cables consist of the

    BTS3006C door status signal cables and BTS3006C external alarm cables.

    5.4.1 Door Status Signal Cables of a BTS3006C/BTS3002E Cabinet

    This topic describes the door status signal cables of a BTS3006C/BTS3002E cabinet. The door

    status signal cables of a BTS3006C/BTS3002E cabinet are used to connect the door status switchat the bottom of a cabinet and monitor the switch status at the door of a cabinet through the

    DMCM.

    5.4.2 BTS3006C/BTS3002E RET Control Signal Cables

    This topic describes the BTS3006C/BTS3002E RET control signal cables. The RET control

    signal cables are used to transmit signals between the DATM and the Bias-Tee on top of a cabinet.

    5.4.3 BTS3006C/BTS3002E External Alarm Cables

    This topic describes the BTS3006C/BTS3002E external alarm cables. The BTS3006C/

    BTS3002E external alarm cables are used to connect the external alarm equipment and monitor

    the power status and environment status through the DMCM.

    5.4.1 Door Status Signal Cables of a BTS3006C/BTS3002E CabinetThis topic describes the door status signal cables of a BTS3006C/BTS3002E cabinet. The door

    status signal cables of a BTS3006C/BTS3002E cabinet are used to connect the door status switch

    at the bottom of a cabinet and monitor the switch status at the door of a cabinet through the

    DMCM.

    Functions

    The BTS3006C/BTS3002E door status signal cables are used to connect the door status switch

    at the bottom of a cabinet and monitor the switch status at the door of a cabinet through the

    DMCM.

    Appearance

    Figure 5-10shows a BTS3006C/BTS3002E door status signal cable.

    5 BTS3006C Cables

    iSite BTS3006C

    Hardware Description

    5-16 Huawei Technologies Proprietary Issue 01 (2007-08-10)

  • 7/28/2019 01-05 BTS3006C Cables

    17/25

    Figure 5-10 Door status signal cable

    123

    View

    A

    X1

    W1

    W2

    X2

    X3

    Pin Description

    Table 5-15 lists the pin assignment for the BTS3006C/BTS3002E door status signal cables.

    Table 5-15 Pin assignment for the BTS3006C door status signal cables

    Wire Pins at X1 End Pins at X2 Endand X3 End

    Wire Color

    W1 X1.1 X2 Blue

    W2 X1.3 X3 Black

    Installation Position

    Table 5-16 lists the installation position of a door status signal cable.

    Table 5-16 Installation position of a door status signal cable

    Cable Name One End (CommonConnector)

    The Other End ( ParallelTerminal)

    Door status cable Connects to DOOR port on

    the DMCM in the main

    cabinet.

    Connects to the door status

    switch at the bottom of a

    cabinet.

    5.4.2 BTS3006C/BTS3002E RET Control Signal Cables

    This topic describes the BTS3006C/BTS3002E RET control signal cables. The RET control

    signal cables are used to transmit signals between the DATM and the Bias-Tee on top of a cabinet.

    Functions

    The RET control signal cables are used to transmit signals between the DATM and the Bias-

    Tee on top of a cabinet.

    iSite BTS3006C

    Hardware Description 5 BTS3006C Cables

    Issue 01 (2007-08-10) Huawei Technologies Proprietary 5-17

  • 7/28/2019 01-05 BTS3006C Cables

    18/25

    Appearance

    The BTS3006C RET control signal cable consists of six independent RF coaxial cables (2.2 m

    long). These cables have the same structure. One end of an RET control signal cable is an SMA

    male connector and the other end is an SMA elbow male connector, as shown in Figure 5-11.

    Figure 5-11 Structure of an RET control signal cable

    SMA connector SMA connector

    W

    X1

    X2

    Pin DescriptionNone

    Installation Position

    Table 5-17 lists the installation positions of an RET control signal cable.

    Table 5-17 Installation position of an RET control signal cable

    Cable Type One End (SMA Elbow MaleConnector)

    The Other End (SMA MaleConnector)

    RET control

    signal cable

    Connects to any ANT port on

    the DATM panel.

    Connects to SMA port on the Bias-

    Tee.

    5.4.3 BTS3006C/BTS3002E External Alarm Cables

    This topic describes the BTS3006C/BTS3002E external alarm cables. The BTS3006C/

    BTS3002E external alarm cables are used to connect the external alarm equipment and monitor

    the power status and environment status through the DMCM.

    Functions

    The BTS3006C/BTS3002E external alarm cables are used to connect the external alarm

    equipment and monitor the power status and environment status through the DMCM.

    Appearance

    A BTS006C/BTS3002E external alarm cable is 9 m long. One end of the cable is a round

    waterproof connector and the other end is a bare wire. According to Table 5-18, a connector is

    required to be made on site to match the bare wire end. Figure 5-12 shows a BTS3006C/

    BTS3002E external alarm cable.

    5 BTS3006C Cables

    iSite BTS3006C

    Hardware Description

    5-18 Huawei Technologies Proprietary Issue 01 (2007-08-10)

  • 7/28/2019 01-05 BTS3006C Cables

    19/25

    Figure 5-12 External alarm cable

    Cylindrical

    waterproof connector

    W

    X1

    A-A

    11

    A

    A

    15

    Pin Description

    Table 5-18 lists the pin assignment for the BTS3006C/BTS3002E alarm wires.

    Table 5-18 Pin assignment for the BTS3006C external alarm cable wires

    Wire Pins at X1 End Wire Color Remarks on Twisted Pair Cable

    W X1.1 Blue TX+

    Red/blue

    X1.2 Orange TX-

    Red/orange

    X1.3 Green RX+

    Green/Red

    X1.4 Brown RX-

    Red/brown

    X1.5 White/blue GND

    X1.7 Blue G1

    X1.5 White/orange GND

    X1.8 Orange G2

    X1.11 White/green GND

    X1.9 Green G3

    X1.11 White/brown GND

    X1.10 Brown G4

    Installation Position

    Table 5-19 lists the installation position of a BTS3006C/BTS3002E external alarm cable.

    iSite BTS3006C

    Hardware Description 5 BTS3006C Cables

    Issue 01 (2007-08-10) Huawei Technologies Proprietary 5-19

  • 7/28/2019 01-05 BTS3006C Cables

    20/25

    Table 5-19 Installation position of an external alarm cable

    Cable Name One End (RoundWaterproof Connector)

    The Other End (Bare Wire)

    External alarmcable

    Connects to ALM port on theDMCM

    Connects to a port on the externalalarm equipment

    5.5 BTS3006C RF Cables

    This topic describes the BTS3006C RF cables. The BTS3006C RF cables consist of the

    BTS3006C RF signal cables and the BTS3006C 1/4-inch RF jumpers.

    5.5.1 BTS3006C/BTS3002E RF Signal Cables

    This topic describes the BTS3006C/BTS3002E RF signal cables. The two types of RF signal

    cables are RF RX signal cables and RF TX signal cables.5.5.2 BTS3006C/BTS3002E 1/4-Inch RF Jumpers

    This topic describes the BTS3006C/BTS3002E 1/4-inch RF jumpers. BBTS3006C/BTS3002E

    1/4-inch RF jumpers are used to complete the signal interconnection between the BTS and the

    antenna system.

    5.5.1 BTS3006C/BTS3002E RF Signal Cables

    This topic describes the BTS3006C/BTS3002E RF signal cables. The two types of RF signal

    cables are RF RX signal cables and RF TX signal cables.

    FunctionsThe two types of RF signal cables are RF RX signal cables and RF TX signal cables.

    l RF RX signal cables: are used to connect the port on the RX channel between the DDPM

    and the DDRM so that the uplink signals can be transmitted.

    l RF TX signal cables: are used to connect the ports on the RX channel between the DDPM

    and the DDRM, between the DDPM and the DDCM/DSCM, and between the DDRM and

    the DDCM so that the downlink signals can be transmitted.

    NOTE

    The BTS3002E does not have the DSCM. Therefore, the RF signal cables are not required to be connected

    with the DSCM for the BTS3002E.

    Appearance

    Two ends of the RF RX signal cables are SMA elbow male connectors. Two ends of the RF TX

    signal cables are N elbow male connectors. Figure 5-13 shows the structure of an RF RX cable

    and an RF TX signal cable.

    5 BTS3006C Cables

    iSite BTS3006C

    Hardware Description

    5-20 Huawei Technologies Proprietary Issue 01 (2007-08-10)

  • 7/28/2019 01-05 BTS3006C Cables

    21/25

    Figure 5-13 Structure of an RF RX signal cable and an RF TX signal cable

    RF TX Cable

    2

    RF RX Cable

    1

    2

    1

    (1) SMA elbow male connector (2) N elbow male connector

    Pin DescriptionNone

    Installation Position

    Table 5-20 lists the installation positions of an RF receive cable and an RF transmit signal cable.

    NOTE

    The BTS3002E does not have the DSCM. Therefore, the RF signal cables are not required to be connected

    with the DSCM for the BTS3002E.

    Table 5-20 Installation positions of an RF RX cable and an RF TX signal cable

    Cable Name One End The Other End

    RF RX signal cable Connects to RX port on the

    DDRM.

    Connects to RX port on the DDPM.

    RF TX signal cable Connects to TX port on the

    DDRM.

    Connects to TX port on the DDPM.

    Connects to TX port on the DDCM.

    Connects to TX port on the

    DDPM

    Connects to COM port on the DDCM

    Connects to TX port on the

    DDPM

    Connects to COM port on the DSCM

    Connects to COM port on

    the DDCM

    Connects to TX port on the DSCM

    5.5.2 BTS3006C/BTS3002E 1/4-Inch RF Jumpers

    This topic describes the BTS3006C/BTS3002E 1/4-inch RF jumpers. BBTS3006C/BTS3002E

    1/4-inch RF jumpers are used to complete the signal interconnection between the BTS and the

    antenna system.

    iSite BTS3006C

    Hardware Description 5 BTS3006C Cables

    Issue 01 (2007-08-10) Huawei Technologies Proprietary 5-21

  • 7/28/2019 01-05 BTS3006C Cables

    22/25

    Functions

    BTS3006C/BTS3002E 1/4-inch RF jumpers are used to complete the signal interconnection

    between the BTS and the antenna system.

    Appearance

    One end of a BTS3006C/BTS3002E 1/4-inch RF jumper is a DIN male connector. The other

    end is a N elbow male connector. The jumpers have two types: 2.2 m and 4 m. Figure 5-14

    shows a BTS3006C 1/4-inch RF jumper.

    Figure 5-14 Structure of a BTS3006C 1/4-inch RF jumper

    W

    12

    (1) DIN male connector (2) N elbow male connector

    Pin Description

    None

    Installation Position

    Table 5-21 lists the installation position of the BTS3006C/BTS3002E 1/4-inch RF jumpers.

    Table 5-21 Installation positions of the 1/4-inch RF jumpers

    CableName

    One End (N Connector) The Other End (DIN Connector)

    1/4 RFjumper

    Connects to the antennaport ANTA or ANTB on

    the DDPM.

    Connects to the feeder of the antenna systemwhen there is no power supply for the TMA.

    Connects to the Bias-Tee port when there is

    power supply for the TMA.

    5.6 Cables Between the BTS3006C and the AuxiliaryEquipment

    This topic describes the cables between the BTS3006C and the auxiliary equipment. The cables

    between the BTS3006C and the auxiliary equipment consist of the signal cables in the externalenvironment alarm box and the power cables between the Sidepower and the BTS3006C.

    5 BTS3006C Cables

    iSite BTS3006C

    Hardware Description

    5-22 Huawei Technologies Proprietary Issue 01 (2007-08-10)

  • 7/28/2019 01-05 BTS3006C Cables

    23/25

    5.6.1 Signal cable of the external environment alarm box in the BTS

    This part describes the function, structure, pin assignment, and installation positions of the signal

    cable of the external environment alarm box in the BTS.

    5.6.2 Power Cables Between the Sidepower and the BTS3006C/BTS3002EThis topic describes the power cables between the Sidepower and the BTS3006C/BTS3002E.

    The power cables between the Sidepower and the BTS3006C/BTS3002E are used to connect

    the Sidepower and the DSEM. The power cables are used to supply power from the Sidepower

    to the DSEM in a cabinet.

    5.6.1 Signal cable of the external environment alarm box in the BTS

    This part describes the function, structure, pin assignment, and installation positions of the signal

    cable of the external environment alarm box in the BTS.

    FunctionThe signal cable of the external environment alarm box is used to transmit the alarm signals to

    the BTS. This helps the BTS take actions to clear the relevant alarms.

    Appearance

    Figure 5-15 shows the structure of the signal cable of the external environment alarm box.

    Figure 5-15 Structure of the signal cable of the external environment alarm box

    X1

    1 2

    X2

    View A

    AB

    W

    View B

    Pos.1

    Pos.9

    Pos.1

    Pos.9

    (1) DB9 male connector (2) DB9 male connector

    Pin Description

    Table 5-22 describes the pin assignment for the signal cable of the external environment alarmbox.

    Table 5-22 Pin assignment for the signal cable of the external environment alarm box

    Pin at the X1 End Pin at the X2 End Wire Type Remarks

    X1.3 X2.2 Twisted pair WARNING_T+

    X1.7 X2.6 WARNING_T-

    X1.2 X2.3 Twisted pair WARNING_R+

    X1.6 X2.7 WARNING_R-

    iSite BTS3006C

    Hardware Description 5 BTS3006C Cables

    Issue 01 (2007-08-10) Huawei Technologies Proprietary 5-23

  • 7/28/2019 01-05 BTS3006C Cables

    24/25

    Installation Positions

    Table 5-23 shows the installation positions of the signal cable for the external environment alarm

    box.

    Table 5-23 Installation positions of the signal cable for the external environment alarm box

    BTS Type One End (DB9 MaleConnector)

    Other End (DB9 Male Connector)

    BTS3012 Connects to the COM1 or

    COM2 port on the DSAC

    The two core wires at the bare wire end

    connect to relevant control devices.

    BTS3012AE Connects to the EAC port on

    the DMLU panel

    The two core wires at the bare wire end

    connect to relevant control devices.

    BTS3006C Connects to the DB9

    connector of the BTS3006C/

    BTS3002E external alarm

    cable

    The two core wires at the bare wire end

    connect to relevant control devices.

    BTS3002E Connects to the DB9

    connector of the BTS3006C/

    BTS3002E external alarm

    cable

    The two core wires at the bare wire end

    connect to relevant control devices.

    5.6.2 Power Cables Between the Sidepower and the BTS3006C/BTS3002E

    This topic describes the power cables between the Sidepower and the BTS3006C/BTS3002E.The power cables between the Sidepower and the BTS3006C/BTS3002E are used to connect

    the Sidepower and the DSEM. The power cables are used to supply power from the Sidepower

    to the DSEM in a cabinet.

    Functions

    The power cables between the Sidepower and the BTS3006C/BTS3002E are used to connect

    the Sidepower and the DSEM. The power cables are used to supply power from the Sidepower

    to the DSEM in a cabinet.

    AppearanceThere are two power cables. One is blue and the other is black. Two ends of the power cable are

    OT terminals. You can shorten the length of the power cable based on the actual situation. Figure

    5-16 shows the power cables.

    Figure 5-16 DC power cable

    5 BTS3006C Cables

    iSite BTS3006C

    Hardware Description

    5-24 Huawei Technologies Proprietary Issue 01 (2007-08-10)

  • 7/28/2019 01-05 BTS3006C Cables

    25/25

    Pin Description

    None

    Installation PositionTable 5-24 lists the installation positions of the power cables.

    Table 5-24 Installation positions of the power cables

    Cable Name One End The Other End

    Power cable between the

    Sidepower and the

    BTS3006C/BTS3002E

    (blue)

    Connects to NEG(-) wire

    post of the DSEM

    Connects to the wiring terminal

    on the output negative

    Miniature Circuit Breaker

    (MCB) of the Sidepower

    Power cable between theSidepower and the

    BTS3006C/BTS3002E

    (black)

    Connects to NEG(+) wirepost of the DSEM

    Connects to the wiring terminalon the output positive copper

    busbar of the Sidepower

    iSite BTS3006C

    Hardware Description 5 BTS3006C Cables

    I 01 (2007 08 10) H i T h l i P i t 5 25