Siemens Building Technologies Building Technologies
Introducing SED2 - Siemens Easy Drive
• The SED2 family of Variable Speed Drives is designed specifically for the HVAC industry
• Provides speed control of fan and pump 3 phase motors • 230V: ½ - 60HP• 480V: 1 – 125HP• 575V: 1 – 125HP
• 6 frame sizes for every application
Siemens Building Technologies Building Technologies
SED2 Features
• Built-in P1 & N2 Communications• Optional LonWorks or Modbus communication interface• Unique low harmonics design limits emitted noise that may
interfere with other devices• Built-in custom PID controls system dynamics, eliminates the
need/cost for separate PID controllers• Pump Controller Staging/Cascading eliminates the cost of
separate controllers; suited for open loop, constant pressure, constant flow-type systems and applications.
• Multi-Level Program Access: Limit, manage, and custom configure the specific parameters unique to the application.
• Eliminates the need and cost for separate line reactors and chokes
• Allows direct sensor input for room temperature control
Siemens Building Technologies Building Technologies
SED2 Features
• Intuitive, easy-to-use internal programming software leads the operator through quick start-up and commissioning
• One Common Interface includes a Basic Operator Panel to operate, set and monitor all drive functions.
• Advanced Operator Panel provides inputting of parameters to multiple drives, multi-line/multi-lingual display, scheduling functions, and can control up to 31 drives on the same network
• Essential Services Mode/Smoke Purge for critical applications where continuous uninterrupted service is essential. Drive will run regardless of system faults and alarms
Siemens Building Technologies Building Technologies
Drive and Motor Protection Features
• Over-voltage
• Motor overload (I2t)
• Short circuit
• Ground fault
• Drive Over-temperature
• Motor Over-temperature (Motor PTC required)
Siemens Building Technologies Building Technologies
SED2 Features
• Built-In Hand Auto Selection– Built into Basic/Advanced
Operator Keypad in lieu of separate device
• Wide Range of I/O– Digital Inputs: 6– Analog Inputs: 2– Relay contact Outputs: 2– Analog Outputs: 2
• Certifications: – UL– cUL– CE
Siemens Building Technologies Building Technologies
Standard I/O
0-10 V2-10 V0-20 mA4-20 mAProgrammable
functions
Form C contactsProgrammable
functions30VDC, 5A240VAC, 2A
2 x analog outputs
2 x digital outputs
RS-485
P1N2USSLonWorks (opt.)Modbus (opt.)
0-10 V2-10 V
0-20 mA4-20 mANi 1000
2 x analog inputs
6 x digital inputs
1 x motor PTC
InsulatedProgrammable
functionsPNP or NPN (sink/source)
SED2
Siemens Building Technologies Building Technologies
VFD Product Line Configurations
Added kit with Protective cover and Gland Plate
Meets UL Type 1 (NEMA Type 1) enclosure standards
Suitable for direct wall mounting
NEMA 12 (IP54)
SED2 only• 200-240V: 1/2 – 60HP• 440-500V: 1 – 125HP• 500-600V: 1 – 125HPFor VFD imbedded applications and local bypass (control panel shop) assembly
(IP20)
Protective Cover
Gland Plate for ConduitNEMA 1
Siemens Building Technologies Building Technologies
SED2 Frame Sizes and Power Range
IP20 & NEMA Type 1
HP .5 .75 1 2 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125
208/240V
480V
575V
A
B
C D E F
A-F denotes VFD frame size
Siemens Building Technologies Building Technologies
• Commissioning sequence is menu-driven and enables the drive to be set up quickly with only 14 parameters
• Filter function arranges parameters to meet user needs• Hand / Auto function for easy commissioning and
maintenance• BOP is standard on all drives
BOP - Basic Operating Panel
Increase or decrease speed
Hand over control to your system (I/O terminals or communication)
Start or stop drive
Siemens Building Technologies Building Technologies
• Provides multilingual clear text information for commissioning and maintenance
• 4 x 30 character backlit display• Uploads and downloads parameter settings from one drive to another• Stores 10 parameter sets• 7-day timer function • Broadcast function allows control of up to 31 drives via one AOP
AOP - Advanced Operating Panel
Mon ON 1 OFF 1 ON 2 OFF 2 ON 3 OFF 3Tue ON 1 OFF 1 ON 2 OFF 2 ON 3 OFF 3Wed ON 1 OFF 1 ON 2 OFF 2 ON 3 OFF 3Thu ON 1 OFF 1 ON 2 OFF 2 ON 3 OFF 3Fri ON 1 OFF 1 ON 2 OFF 2 ON 3 OFF 3Sat ON 1 OFF 1 ON 2 OFF 2 ON 3 OFF 3Son ON 1 OFF 1 ON 2 OFF 2 ON 3 OFF 3
7-Day Timer Function
Siemens Building Technologies Building Technologies
PID Controller Feature
Ni 1000
Analog or Ni 1000 Sensor Direct Connection• With direct connection of analog or Ni 1000 temperature sensor inputs,
implementing low-cost temperature control loops with one cooling or heating sequence is easy.
• The built-in PID controller with anti-windup functionality is optimized for HVAC requirements. The PID controller has a hibernation mode which stops the drive if it runs at a user-defined minimum speed for a given time.
Siemens Building Technologies Building Technologies
V-Belt Monitoring Feature
The SED2 ensures reliable V-belt monitoring without the expense of an external sensor. Both speed and torque are compared to a user-defined tolerance band. If the parameters do not match, the drive trips in the event of V-belt failure.
Also, the SED2 is also able to monitor a pulse sequence from the sensor detecting rotation on the fan shaft.
Speed
Torque
Siemens Building Technologies Building Technologies
Built-in Pump Cascading Feature
This function allows for the control of up to two additional, cascaded pumps. With the two relay output contacts, the SED2 performs the cascading logic without additional controllers or I/O cards.
Pres
sure
dem
and
100%
2 31Cascade
P
Contact out 2
Contact out 1
Siemens Building Technologies Building Technologies
Menu-driven Quick Commissioning
The drive’s initial settings consider the hard wired or direct (P1) connections commonly used with a BAS system. The quick commissioning mode using the standard operating panel, provides for quick and straightforward drive set up.
-Set point DC 0...10 V
- Start / stop
- Running / fault
- Fault acknowledge
- w/ P1: More than 95
parameters
BAS3AC “Hard wiring”
Commissioning Time ~ 10 Minutes
P1
or
Siemens Building Technologies Building Technologies
Accessories
• Door mounting kitsuitable for BOP and AOP
• Modbus interface cable• LonWorks interface module• Harmonics analysis software • Commissioning software
– PC interface to SED2 Panel door
AOP or BOP
Cover (IP56 protection)
Siemens Building Technologies Building Technologies
For more info, see the Features and Benefits menu on this CD
• Low harmonics design• Small enclosure size• Many standard
features• Reduces operating
cost• Low power losses/high
efficiency• Minimal effect on
customer power• Wide power range –
from ½ to 125 HP
Siemens SED2 VFD Advantages