9
- Where are the entry points of the instrument - Physical External links - Overview of the External Interfaces - Status - Conclusion EUSO-BALLOON DESIGN REVIEW, 18.12.2012, CNES TOULOUSE Sylvie Dagoret-Campagne LAL, Orsay EUSO-BALLOON External Interfaces

- Where are the entry points of the instrument - Physical External links

  • Upload
    ferrol

  • View
    38

  • Download
    0

Embed Size (px)

DESCRIPTION

EUSO-BALLOON DESIGN REVIEW, 18.12.2012, CNES TOULOUSE. EUSO-BALLOON External Interfaces. Sylvie Dagoret-Campagne LAL, Orsay. - Where are the entry points of the instrument - Physical External links - Overview of the External Interfaces - Status - Conclusion. - PowerPoint PPT Presentation

Citation preview

Page 1: -  Where are the entry points of the instrument -  Physical External links

- Where are the entry points of the instrument

- Physical External links

- Overview of the External Interfaces

- Status

- Conclusion

E U S O - B A L L O O N D E S I G N R E V I E W, 1 8 . 1 2 . 2 0 1 2 , C N E S T O U L O U S E

Sylvie Dagoret-CampagneLAL, Orsay

EUSO-BALLOON External Interfaces

Page 2: -  Where are the entry points of the instrument -  Physical External links

CDR – 18.12.2012

External Interfaces 2

Where are the entry points inside the instrument

IR-CAMIRCAM

EC-HV

EC-DYNODE

HVPS2

HVPS1

MA

PMT

EC-ANODE

EC-ASIC

PDM-BBatteries

PWP

LVPS

-DP1

LVPS

-DP2

LVPS-PDM

LVPS

-HK

HK

CCB

CLKB

GPSR

CPU

DST

SIREN

CNES Telemetry

EXT

Bat Controller

TLS

Sensors

Motors

SPACEWIRE/PCI

EC-Front

EC-Back

DP PDM

data

Power 28 V

Telemetry

Power 5 V

HVPS control&status

monitoring

Page 3: -  Where are the entry points of the instrument -  Physical External links

CDR – 18.12.2012

External Interfaces 3

External Physical links

RS232/RS422 conv

Ethernet

ON/OFF +/- 12 V

ON/OFF 3 V

HK CPULVPSHK

TC TM

wifi GPS

Page 4: -  Where are the entry points of the instrument -  Physical External links

Overview of the external interfaces

A- SIREN-LVPS-HK- Purpose is to initiate a turn ON/OFF initial procedure for the instrument- Technically : two open drain links (SIREN-TOR) over the ± 12 V and 3.3 V converters of LVPS-HK B-SIREN-HK- High level commands implying the instrument life (turn ON/OFF of various components by

the action on their supply voltage through HK)- Standard Telecommand (TC) for the instrument control, - Standard Telemetry monitoring (TM) on the power supplies (Voltage), Temperature of the

components,- Technically : RS232/RS422 interface

C-SIREN-CPU- Retrieve information on runs and events like the trigger rate,- Retrieve information from selected events according criteria adapted to the allowed

transmission rate,- Issue CPU commands.- Technically Ethernet RJ45

CDR – 18.12.2012

Instrument and Objectives 4

Page 5: -  Where are the entry points of the instrument -  Physical External links

Overview of the external interfaces

A- SIREN-LVPS-HK- Purpose is to initiate a turn ON/OFF initial procedure for the instrument- Technically : two open drain links (SIREN-TOR) over the ±12 V and 3.3 V converters of LVPS-HK B-SIREN-HK- High level commands implying the instrument life (turn ON/OFF of various components by

the action on their supply voltage through HK)- Standard Telecommand (TC) for the instrument control, - Standard Telemetry monitoring (TM) on the power supplies (Voltage), Temperature of the

components,- Technically : RS232/RS422 interface

C-SIREN-CPU- Retrieve information on runs and events like the trigger rate,- Retrieve information from selected events according criteria adapted to the allowed

transmission rate,- Issue CPU commands.- Technically Ethernet RJ45

CDR – 18.12.2012

Instrument and Objectives 5

Page 6: -  Where are the entry points of the instrument -  Physical External links

Overview of the external interfaces

A- SIREN-LVPS-HK- Purpose is to initiate a turn ON/OFF initial procedure for the instrument- Technically : two open drain links (SIREN-TOR) over the ±12 V and 3.3 V converters of LVPS-HK B-SIREN-HK- High level commands implying the instrument life (turn ON/OFF of various components by

the action on their supply voltage through HK)- Standard Telecommand (TC) for the instrument control, - Standard Telemetry monitoring (TM) on the power supplies (Voltage), Temperature of the

components,- Technically : RS232/RS422 interface

C-SIREN-CPU- Retrieve information on runs and events like the trigger rate,- Retrieve information from selected events according criteria adapted to the allowed

transmission rate,- Issue CPU commands.- Technically Ethernet RJ45

CDR – 18.12.2012

External Interfaces 6

Page 7: -  Where are the entry points of the instrument -  Physical External links

Status of External Interfaces

interface Connectors Pin assignement

cable protocol Status

SIREN-CPU RJ45 OK OK Ethernet OK

SIREN-LVPS-HK

D-Sub 15 F OK OK Electrical(open drain)

OK

SIREN-HK OK OK RS232/RS422

OK

CDR – 18.12.2012

External Interfaces 7

CPU HK Microcontroller

Page 8: -  Where are the entry points of the instrument -  Physical External links

CDR – 18.12.2012

External Interfaces 8

Conclusions

• Component links done according state of the art EMC rules• Refer to the Electrical Architecture document and Pierre Prat’s

presentation,

• All connectors and pin assignment done for each component,• Refer to the Electrical Interface Document and to Michel Dupieux’s

presentation

• Cables procurement attributed,• Refer to the subsystem manager’s presentations

• Functions and purposes defined,• Refer to the software documents for numeric interfaces and Francesco

Cafagna’s presentation

• No remaining Open point

Page 9: -  Where are the entry points of the instrument -  Physical External links

CDR – 18.12.2012

External Interfaces 9

END ON EXTERNAL INTERFACES

DP box modules

CPUHKLVPSHK

CLK GPSLVPS1LVPSPDM

RS232/RS422 conv

Ethernet

ON/OFF +/- 12 V

ON/OFF 3 V

CCB