© 2014 HGST, INC. | HGST CONFIDENTIAL
Giorgio IppolitiSenior Technical Support Southern Europe & Israel
HGST Products for Datacenter
© 2014 HGST, INC. | HGST CONFIDENTIAL 2
Agenda
• New Product Overview: HDD
• New Product Overview: SSD
• HGST SW Solutions
© 2014 HGST, INC. | HGST CONFIDENTIAL
New Products: HDD
© 2014 HGST, INC. | HGST CONFIDENTIAL 4
Purpose built for CAPACITY INTENSIVE applications
Capacity Enterprise
7th generation, legendary reliability, last in-air capacity enterprise
6TB
ULTRASTAR®
7K6000
High Scale Cloud
8TB
2nd generation, new mainstream capacity with breakthrough TCO
ULTRASTAR®
He8
OnlineCool
10 TB
Value and innovation for Active Archive workloads
WORLD’S FIRST 10TB HDD
© 2014 HGST, INC. | HGST CONFIDENTIAL 5
Highest areal density for mainstream enterprise
6TB 3.5in. 2M HR MTBF
shipping TODAYLAST IN AIR
ANNOUNCING
© 2014 HGST, INC. | HGST CONFIDENTIAL 6
World’s highest capacity mainstream enterprise HDD
8TBPMR
33%capacity boost
23%lower power
shipping TODAY
worksanywhere
ANNOUNCING
© 2014 HGST, INC. | HGST CONFIDENTIAL 7
Air – 5 Disk Helium – 7 Disk
HelioSeal™ Value
The Helium HDDs Solve Problems
Thinner Platters = More Platters per HDD
More Platters = Higher Capacity = Better Density
Less Drag from Helium = ~23% Less Power Consumed
Less Power = 4◦C Cooler Operation = Lower PUE
Cooler Operation = Higher Reliability
© 2014 HGST, INC. | HGST CONFIDENTIAL 8
World’s first 10TB SMR enterprise-class HDD
HeHelioSeal™
SMR COLDstorage
sampling NOW
3.5in.
ANNOUNCING
© 2014 HGST, INC. | HGST CONFIDENTIAL 9
Key Product Specifications Ultrastar15K600
Ultrastar C15K600
Form Factor 3.5 LFF 2.5 SFF
Capacity 600/450/300 600/450/300
Rotational Speed 15K 15K
SAS Interface 6Gb/s 12Gb/s
Cache 64MB 128MB
Format Options 512n 4Kn/512e/512n
Ultrastar C15K600GENERATIONAL IMPROVEMENTS
70% LESS FOOTPRINT
KEY IMPROVEMENTS
38% FASTER SEQUENTIALPERFORMANCE
14% FASTER RANDOMREAD PERFORMANCE
2.5X FASTER RANDOMWRITE PERFORMANCE
54% LOWER ACTIVE &IDLE POWER
2XSAS INTERFACEBANDWIDTH
2XCACHEBUFFER SIZE
Note : Random Read performance improvement quoted at QD 1
Random Write performance improvement quoted at QD=8
Ultrastar C15K600 performance quoted for 4K/512e aligned case
© 2014 HGST, INC. | HGST CONFIDENTIAL 10
50% MORE CAPACITY
23% FASTER SEQUENTIALPERFORMANCE
10% FASTER RANDOMREAD PERFORMANCE
2.5X FASTER RANDOMWRITE PERFORMANCE
2XSAS INTERFACEBANDWIDTH
2XCACHEBUFFER SIZE
4X IOPS / $ / GB
Cobra-F boasts significant generational improvements over Cobra-E/EP
Ultrastar C10K1800GENERATIONAL IMPROVEMENTS KEY IMPROVEMENTS
Key Product SpecificationsUltrastar10K900/ 10K1200
Ultrastar C10K1800
Highest Capacity 900GB/1.2TB 1.8TB
Rotational Speed 10K 10.5K
SAS Interface 6Gb/s 12Gb/s
Cache 64MB 128MB
Format Options 512n 4Kn/512e/512n
Security Options TCG ISE/TCG/FIPS
© 2014 HGST, INC. | HGST CONFIDENTIAL
New Products: SSD
© 2014 HGST, INC. | HGST CONFIDENTIAL 12
ULTRASTAR® SAS SSD FAMILYIdeal for data-intensive application acceleration
FLASHMAX® III1.1TB - 2.2TB capacitiesHHHL form factor
WORLD’S FASTEST SSDDemonstrating phase change technology
ULTRASTAR® SN100 SERIES NVMe PCIe SSD
Sampling Now
Recent SSD ANNOUNCEMENTS
© 2014 HGST, INC. | HGST CONFIDENTIAL 13
Ultrastar SSD800MH.BUltrastar SSD1600MMUltrastar SSD1600MR
Industry’s most advanced and highest performing
12Gb/s SAS MLC SSDs
Leverages HGST’s industry-leading HDD and SSD
technology
Delivers solid reliability, endurance and sustained
performance
Fully plug compatible with HGST Ultrastar SSDs, 10K
and 15K HDDs
The Most Advanced Enterprise Class 12Gb/s MLC SSD
SECUREDENCRYPTION
TECHNOLOGYINNOVATION
FEATURES
HIGHEST RELIABILITY
FASTPERFORMANCE
© 2014 HGST, INC. | HGST CONFIDENTIAL 14
FlashMAX IIIACCELERATING APPLICATION PERFORMANCE
1.1TB AND 2.2 TB CAPACITIES HHHL FORM FACTOR
60% BETTER RANDOM READ PERFORMANCE
20% BETTER RANDOM R/W PERFORMANCE
MAXIMUM PRICE PERFORMANCE
LOW TOTAL COST OF OWNERSHIP
© 2014 HGST, INC. | HGST CONFIDENTIAL 15
Ultrastar SN100 SeriesACCELERATING APPLICATION PERFORMANCE WITH NVME
STANDARD NVME DRIVER SUPPORT EASE OF DEPLOYMENT AND LOWER COST OF OWNERSHIP
FAST PERFORMANCE
3.0 GB/S READ BANDWIDTH300K MIXED RANDOM IOPSUP TO 3.2 TB
HHHL AND SERVICEABLE SFF FORM FACTORS
CLUSTERING, HA AND ADVANCED CACHING
HIGH CAPACITY
FLEXIBILITY
SOFTWARE INNOVATION
© 2014 HGST, INC. | HGST CONFIDENTIAL
SW & Solutions
© 2014 HGST, INC. | HGST CONFIDENTIAL 17
Our software combines server-side shared SSDs with the data center storage hierarchy
Device Manager
ServerCache
Application Acceleration
Read Caching & Writeback Caching
For Standalone Windows & Linux
HA
Synchronous Replication
Fail-Over
Low Latency
Infiniband
Linux
Share
Shared Flash
Low Latency
High Performance
Linux
Oracle RAC
Profiler
Capacity Planning
Optimize Flash Usage
Caching Analysis
For Standalone Windows & Linux
ClusterCache
Discover
Monitor
Manage
Report
For Standalone Windows, Linux, & Solaris
Clustered Server Caching
Endurance
Ultimate Performance
Linux
Oracle RAC
vHA
Space
Server SAN Volume Manager
Add vSpacesReplicateShareManageLinux
HGST Software Family
© 2014 HGST, INC. | HGST CONFIDENTIAL 18
HGST Device Manager
Support for HGST UltraStar SAS and FlashMAX PCIe Coming in June 2014
Easy Installation with Efficient
Configuration Management•Prepare SSD for use•Firmware updates
Comprehensive Monitoring•Alerts
•Usage Gauges
Health Check to Ensure Data Integrity•Self Check
•Monitor Status
Cross Platform Flash Management•MS Windows Server 2003/2008/2012 & XP
•Red Hat Enterprise 5/6, OEL 5.6, & SUSE Linux 11 •Solaris 10/11/11.1 and NexentaStor 3.1/4
© 2014 HGST, INC. | HGST CONFIDENTIAL 19
Optimal Cache Configuration
I/O
I/OI/O
Ser
ver
Storage
SSD
Free Utility That Uncovers IO Bottlenecks
Make informed decisions based on actual workloads
Optimizes the usage of SSDs by recommending the best SSD cache configuration
HGST Profiler
© 2014 HGST, INC. | HGST CONFIDENTIAL 20
Duplicate Blocks
ABCDEFGHABCDEFGH
ABCDEFGHABCDEFGH
ABCDEFGHABCDEFGH
ABCDEFGHABCDEFGH
Δ Δ
ABCDEFGHABCDEFGH
CDCDEFGHCDCDEFGH
Similar Blocks
Shifted Blocks
ABCDEFGHABCDEFGH
HABCDEFGHABCDEFG
ABCDEFGHABCDEFGH
§ §
Shuffled BlocksABCDEFGHABCDEFGH
EFGHABCDEFGHABCD
ABCDEFGHABCDEFGH
ζ ζ
Ξ Ξ
Metadata
SERVER NETWORK STORAGE
SANAPPLICATION
VIRIDENT SERVERCACHE
FLASH ARRAY SSD / HDDSWITCHRAMCPUAPPLICATION
HGST ServerCacheSingle Server Caching
Delta Compression
Elegant GUI
© 2014 HGST, INC. | HGST CONFIDENTIAL 21
Virident Cluster SolutionsEnabling a True Performance Tier for the Software Defined Flash World
vShare
I/O
vShare
I/O
vShare – Clustered FlashMAX for sharing across multiple servers
SecondaryPrimary
vHA
Reads Writes
vHA – Synchronous Replication between FlashMAX cards
Shared Database
ClusterCache
SAN
ClusterCache
ClusterCache - Accelerate a SAN by sharing FlashMAX cards
SAN
I/O I/O
vShare over Cluster Cache for Oracle RAC
© 2014 HGST, INC. | HGST CONFIDENTIAL 22
HGST Virident Solutions – “Big Sky” – August 2014
• Up to 16 nodes in a cluster
• Using 4.8TB FlashMAX II = 38.4TB logical volume
• Define vSpaces for logical volumes
• Define Any-to-Any vHA Fail-Over
• Ethernet or Infiniband
• iSCSI-like driver support
Up to 38.4TB
© 2014 HGST, INC. | HGST CONFIDENTIAL 23
Application acceleration equals business impact
Up to 5x performance and 50% cost to
accelerate Oracle RAC
37% server consolidation savings
for hyperscale apps
Clustering improves Flash utilization by 50% or more
© 2014 HGST, INC. | HGST CONFIDENTIAL 24
Application Support
VSAN, vFRC, Horizon with View
Smart Flash Cache, Preferred Reads, RAC, All Flash
SQL Server, SharePoint, Exchange, Hyper-V
Server Consolidation, vHA Synchrounous Replication
Server Consolidation
Caching for SAN Acceleration
HA Fail-Over for VSAN Alternative
PCIe Device Encryption
© 2014 HGST, INC. | HGST CONFIDENTIAL 25
Create Disk Stripe (Replaces SAN Controller RAID)
Disk Group must have 1 SSD and 1 HDD
VSAN
vSphere Flash Read Cache Infrastructure
vSphere Flash Read Cache
APP
OS
APP
OS
APP
OS
APP
OS
APP
OS
vSphere
Flash - A New Tier in vSphere
vSphere Flash Read Cache
vSphere Flash Read Cache
vFRC
VMware
© 2014 HGST, INC. | HGST CONFIDENTIAL 26
VMware
View Servers
Domain Controller
VDI Cluster(& Personas)
VDI
© 2014 HGST, INC. | HGST CONFIDENTIAL 27
Oracle Single Instance
SAN
Storage Array
Preferred ReadsClusterCache
© 2014 HGST, INC. | HGST CONFIDENTIAL 28
Oracle RAC
SAN
Storage Array
Management Server
Infiniband or Ethernet
ShareCache
© 2014 HGST, INC. | HGST CONFIDENTIAL 29
RAC Node 2
Cisco NexusEthernet Switch
(stacked)
RAC Node 4
RAC Node 3
RAC Node 5
(2) FlashMAX II – 4.4TB Per NodeConfigured as Primary Storage using ASM26.4 TB Total RAC Storage Capacity
10GbE(Multiple VLANs)
Communications between FlashMAX PCIe Cards will share 10GbE ethernet ports, will use dedicated VLAN
RAC Node 1 RAC Node 6
Internal Cloud
Oracle 6-Node RAC on EthernetSix Node Oracle RAC ConfigurationDell R720 Intel Dual Port 10GbE NIC(2) HGST FlashMax II – 2.2TB
ALL DB storage is 100% flashRet Hat Enterprise Linux (6.4)Oracle RAC with ASM (11g)
Total DB size = 7+TBConfiguration is fully supported by Oracle
© 2014 HGST, INC. | HGST CONFIDENTIAL 30
1 TB 10 TB 100 TB$0
$100,000
$200,000
$300,000
$400,000
$500,000
$600,000
$700,000
$800,000
$900,000
$1,000,000
FlashMAX Exadata SAN
82% 91%
%Savings
70%78%
%Savings24%
50%
%Savings
Flash Storage for Oracle and Oracle RAC Consistently high all-flash performance with linear scalability
DBAs fully control storage resources with Oracle ASM
0.5 TB to 72 TB of flash in a standard x86 server
At a fraction of SAN or Exadata cost
© 2014 HGST, INC. | HGST CONFIDENTIAL 31
Oracle RAC Validation
2x HP ProLiant DL380p Gen8
Mellanox IS5023 QDR Infiniband Switch
1 X Dual Port Mellanox MT27500 [ConnectX-3] 40GB
Oracle 12c (Single Instance & Real Application Clusters)
Oracle Linux 6 Update 5 using ASMLIB
HGST FlashMAX vShare software enables shared server-side flash storage for Oracle RAC. This is the first configuration validated by Oracle using PCIe Flash.
2x HGST FlashMAX II 1.1TB
HGST FlashMAX II and vShare received Oracle Validation on April 8, 2014. The validated stack includes:
http://linux.oracle.com/pls/apex/f?p=102:2:1483545518795336::NO::P2_VC_ID:649
© 2014 HGST, INC. | HGST CONFIDENTIAL 32
MicrosoftExchangeSQL Server & SharePoint
• Reductions in latency
• Increases in IOPs
• Improved TCO & ROI
© 2014 HGST, INC. | HGST CONFIDENTIAL 33
SQL Server
33
• 48X improvement in report generation• 5X improvement in IOPs• Significant improvement in User Experience• Space and Power Savings
HP DL3 ServersHP LeftHand SAN
Before
Synchronous replicationBetween LeftHand Arrays
New HP Servers with FlashMAX II
After
Asynchronous replicationbetween PCIe Devices
© 2014 HGST, INC. | HGST CONFIDENTIAL 34
Microsoft Exchange
Latency 100ms
Before
Latency 2ms
After
• 120,000 mailboxes, 56 servers, replicated to SAN (DAGs)
• Average load time for 10MB attachment from 3 minutes to 5 seconds
© 2014 HGST, INC. | HGST CONFIDENTIAL 35
Tier 0 Tier 1 Tier 2 Tier n
Flash SAS SATA Cloud
Automated Tiering
2.2TB 2.2TB 550GB550GB
LUN 12.75TB
LUN 22.75TB
Windows 2012 Servers
Windows 2008 R2 Client
10Gbps Ethernet
1Gbps Ethernet
Ethernet Switch
. Full Clone Snapshot
. Differential Snapshot 1
. Differential Snapshot 2
. Differential Snapshot 3
. Full Clone Snapshot
. Differential Snapshot 1
. Differential Snapshot 2
. Differential Snapshot 3
Asynchronous Replication
Microsoft Storage Virtualization
© 2014 HGST, INC. | HGST CONFIDENTIAL 36
NoSQL Databases - MongoDB
Corosync
Pacemaker
Secondary vHA store for Shard1
Primary vHA store for Shard1
Sync
Secondary vHA store for Shard2
Primary vHA store for Shard2
Sync
MongoDB Shard 1 MongoDB Shard 2
MongoDB Query Router
Workload A Read /Write mix Workload B Reads 95% Workload F Update Workload F RMW0
1
2
3
4
5
6
7
HGST FlashMax II vs Fusion-io for MongoDB
HGST SSD
Fusion-IO
HGST 6x Faster
HGST 2x Faster
FIO slightly Faster
HGST 2.5x Faster
© 2014 HGST, INC. | HGST CONFIDENTIAL 37
Before
MASTER 1
SLAVE 1 (idle)
Rep
licat
ion
@ t
ran
sact
ion
MASTER 2
SLAVE 2 (idle)
Rep
licat
ion
@ t
ran
sact
ion
After
MASTER 1COPY of 2
MASTER 2COPY of 1
Rep
licat
ion
@ b
lock
-IO R
eplication@
blo
ck-IO
MySQL Reference Architecture:Active :: Active Database Replication
• Consolidate HA servers 2:1, CAPEX reduction• Much faster replication thanks to block-level vHA replication• All nodes are active masters and passively replicate volumes of peer at block level• On failure of a node, paired node runs 2 instances until recovery
© 2014 HGST, INC. | HGST CONFIDENTIAL 38
VM1 VM2 VM3 VM4 VM5 VM6
• Single points of failure
• Single server caching
• Dedicated Host/SSD
• Manage Individual SSDs/Hosts
Before
• No single points of failure
• Shared Cache Pool
• Shared Pool SSDs/VM
• Centralized SSD Management
VM4 VM5 VM6VM2 VM3VM1
After
vSpace for KVM Clustering (VSAN Alternative)
© 2014 HGST, INC. | HGST CONFIDENTIAL 39
ClusterCache for Block I/O SANs
Writes go to both Flash and backend storage
Reads from Flash unless Read-miss
Writes directly to flash, lazy writes to backend
Reads from flash, unless Read-miss
Writes only to backend storage
Reads from Flash, unless Read-miss
Write-through Mode
W R
ClusterCache ClusterCache
Write-back Mode
W R
ClusterCache
Write-around Mode
RW
© 2013 HGST, INC. | HGST CONFIDENTIAL 40
Thank You
© 2013 HGST, INC. | HGST CONFIDENTIAL 41
BACKUP
© 2014 HGST, INC. | HGST CONFIDENTIAL 42
Combining InnovationsMore disks, more bits per disk
© 2014 HGST, INC. | HGST CONFIDENTIAL 43
What is Shingled Magnetic Recording?
Conventional PMR HDD
Data in Discrete Tracks
SMR HDD
Data in Overlapped Tracks
For All Typical Datacenter Workloads
Full Random Reads and Writes
For Write Once, Read Many Workloads
Sequential Writes, Full Random Reads
© 2014 HGST, INC. | HGST CONFIDENTIAL 44
Data is recorded to Media Cache location
closest to the head
Final writing to homecompleted during
background idle time
Step1
Step 2
Enhanced Write Performance - ~2.5X avg. improvement in Random Write
performance for aligned 4Kn/512e workloads
Improved Reliability - 100% data integrity across unexpected power loss
Firmware Based Implementation- Sophisticated firmware algorithm implements
caching mechanism without additional flash or NVC
HGST’s disk-based caching technology provides a large Non-Volatile Cache (NVC) on the media that results in improved reliability and data integrity during unexpected power loss along with a significant improvement in write performance (even at high workloads compared to solutions with limited NAND or flash-based NVC)
Media Cache boosts write performance of 4Kn/512e aligned workloads up to ~2.5X
Media Cache
Note: Disk space used for Media Cache is < 1% of total user capacity and is separate
from the user LBA space