Degraded & Leaking Pipes

Page 3: The Luse Companies Pipe Repair Service

Composites & Clamps are used in a variety of industries

Page 4: The Luse Companies Pipe Repair Service

What are my on-line leak repair What are my on-line leak repair options?options?

Photos used are courtesy of AirLogistics, Luse Thermal, & PowerWrap LP

1.Composite fiber for pipes with exterior nicks, dents, corrosion, and other degradation causing wall mass loss

2.Composite fiber for pipes with interior wall mass loss up to 80%; typically caused by corrosion. Leaking may or may not be present.

3. Mechanical clamps for leaking pipes or to shut off two ends to replace middle section of pipe

Page 5: The Luse Companies Pipe Repair Service

The Luse Companies The Luse Companies

Pipe Repair ServicePipe Repair Service

Photos used are courtesy of AirLogistics, Luse Thermal, & PowerWrap LP

Page 6: The Luse Companies Pipe Repair Service

When the customer can’t shut down and the best

option is live repair using 100% USA made products, installed by certified technicians, and backed by a full

warranty

Page 7: The Luse Companies Pipe Repair Service

Composite Repair Systems

•Cost effective engineered repairs for external/internal corrosion or erosion

•Mechanical or structural strength restored to original design

•Repairs performed on-line avoiding lost production

•Installed by certified trained technicians to validate high quality

•Meets ASME PCC-2 Article 4.1 and ISO TS24817 standards

•Cost savings over traditional repair methods

Page 8: The Luse Companies Pipe Repair Service

AirLogistics CompositesAirLogistics Composites

Page 9: The Luse Companies Pipe Repair Service
Page 10: The Luse Companies Pipe Repair Service

How strong are Aqua-Wrap & PowerSleeve composites ?

Page 11: The Luse Companies Pipe Repair Service

Unreinforced Burst Test

P burst = 1,408 psi (unreinforced)

Page 12: The Luse Companies Pipe Repair Service

Reinforced Burst Test

Pburst = 4,008 psi (reinforced)

Page 13: The Luse Companies Pipe Repair Service

Luse/Air Logistics provides an engineered system composed of:

1.Form used to gather all the information related to the problem at hand

2. Recommended repair design

3.Calculation details supporting the repair design

4.Materials to be used

Page 14: The Luse Companies Pipe Repair Service
Page 15: The Luse Companies Pipe Repair Service
Page 16: The Luse Companies Pipe Repair Service
Page 17: The Luse Companies Pipe Repair Service
Page 18: The Luse Companies Pipe Repair Service
Page 19: The Luse Companies Pipe Repair Service
Page 20: The Luse Companies Pipe Repair Service
Page 21: The Luse Companies Pipe Repair Service

Some Examples of Some Examples of Applications where Applications where

Aqua-Wrap® Aqua-Wrap® can provide solutions can provide solutions

Page 22: The Luse Companies Pipe Repair Service

Aqua-Wrap® products and services: Aqua-Wrap® products and services: ““On-Line” pipe repair of rusted, pitted, thinning wall On-Line” pipe repair of rusted, pitted, thinning wall thickness even while the piping is under pressure in thickness even while the piping is under pressure in some cases. Product used should conform to ASME some cases. Product used should conform to ASME PCC-2, DOT, ASME B31.4 and API 570 ensuring pipe line PCC-2, DOT, ASME B31.4 and API 570 ensuring pipe line integrity.integrity.

Page 23: The Luse Companies Pipe Repair Service
Page 24: The Luse Companies Pipe Repair Service

Duct tape does have 1,000 uses !!!

Page 25: The Luse Companies Pipe Repair Service

A water line in a pit.A water line in a pit.

Page 26: The Luse Companies Pipe Repair Service

Fire water line with thin wallFire water line with thin wallThe line will be reinforced and brought back to its The line will be reinforced and brought back to its

original strength while in service.original strength while in service.

Page 27: The Luse Companies Pipe Repair Service

Drain Line with paper thin wallDrain Line with paper thin wall

Page 28: The Luse Companies Pipe Repair Service

Cooling Water line RepairCooling Water line Repair

Page 29: The Luse Companies Pipe Repair Service

The clamp can stay in place. We will entomb it with our composite fiber system.

Page 30: The Luse Companies Pipe Repair Service

8” Stainless Steel Repair Clamp

To provide a more permanent repair, bolt-on repair clamps can be encapsulated with composite. Restores strength and integrity to the pipe.

Page 31: The Luse Companies Pipe Repair Service

Coal Dust Line RepairCoal Dust Line Repair

Page 32: The Luse Companies Pipe Repair Service

16” Casing for a High Power Electric Line.16” Casing for a High Power Electric Line.

Page 33: The Luse Companies Pipe Repair Service

Electric Transmission LineElectric Transmission Line

Page 34: The Luse Companies Pipe Repair Service

Gas Storage StationGas Storage Station

Page 35: The Luse Companies Pipe Repair Service

Some Case Studies of Some Case Studies of

Aqua-Wrap® SolutionsAqua-Wrap® Solutions

Page 36: The Luse Companies Pipe Repair Service

Repair Bell & Spigot joint on a 24” steel water line.

F.A.C.S.F.A.C.S.™™ Products Used Products Used

10” x 30’ Aquawrap® Stricture Banding™

5/20 Epoxy Stick™ BP-1 Primer™

1 2

3 54

Copyright © 2002 Air Logistics Corporation

Page 37: The Luse Companies Pipe Repair Service

6-foot Diameter, 70-foot high, Stainless Steel Vessel

Tiny cracks had formed in the vessel wall. The tower was wrapped for reinforcement and to prevent any future leakage.

F.A.C.S.F.A.C.S.™™ Products Used Products Used

Standard PowerSleeve® Aquawrap® 10’ x 60’ rolls and Aquawrap® 10’ x 150’ rollsStricture Banding™

Copyright © 2002 Air Logistics Corporation

Page 38: The Luse Companies Pipe Repair Service

24” Effluent Water Line

Repair external corrosion damage and reinforce the line.

F.A.C.S.F.A.C.S.™™ Products Used Products Used

Aquawrap® 10” x 60’ RollsAquawrap® 4” wide Bear™ BP-1 Primer™

Stricture Banding™ Contour Gel

Copyright © 2002 Air Logistics Corporation

Page 39: The Luse Companies Pipe Repair Service

8” Crude Oil Line

Repair external corrosion damage and reinforce the line.

F.A.C.S.F.A.C.S.™™ Products Used Products Used

Aquawrap® 10” x 30’ RollsAquawrap® 4” wide Bear™ BP-1 Primer™

Stricture Banding™

Copyright © 2002 Air Logistics Corporation

Page 40: The Luse Companies Pipe Repair Service

Flapper Valve off of Electrical Transformer

Repair active transformer oil leak on valve. Composite enclosure was drilled, tapped, and injected with a leak control sealant.

F.A.C.S.F.A.C.S.™™ Products Used Products Used

Aquawrap® 8” x 30’ Rolls Heavy Fabric (24 oz.) Aquawrap® 4” wide Bear™ BP-3 Primer™

Copyright © 2002 Air Logistics Corporation

Page 41: The Luse Companies Pipe Repair Service

Concrete Bridge Support

Repair Damaged Concrete around support and reinforce as needed.

F.A.C.S.F.A.C.S.™™ Products Used Products Used

Aquawrap® BP-1 Structural Adhesive Aquawrap® 22-71 G-03 Aquawrap® 22-71 G-06 Structural Cloth

21 3

4 5

7

6

8

Copyright © 2002 Air Logistics Corporation

Page 42: The Luse Companies Pipe Repair Service

Concrete Bridge Support

Repair Damaged Concrete around support and reinforce as needed.

F.A.C.S.F.A.C.S.™™ Products Used Products Used

Aquawrap® BP-1 Structural AdhesiveAquawrap® 22-71 VeilAquawrap® 22-71 Structural Cloth

Copyright © 2002 Air Logistics Corporation

Page 43: The Luse Companies Pipe Repair Service

24” Natural Gas Transmission Line

Serious corrosion had attacked the underside of this pipeline. Nearly 78% of the wall had been eaten away! Aquawrap® was used to restore integrity to the pipe and allowed the customer to continue normal operation of the system.

Products Used Products Used

Aquawrap® 10” x 150’ rollsFiller CompoundAquawrap® BP-1 Primer™ Stricture Banding™

Copyright © 2002 Air Logistics Corporation

Rubberized Tape with Vinyl backing to provide additional buried pipe protection.

Page 44: The Luse Companies Pipe Repair Service

Repair Concrete Columns and Crossbeams.

Repair Salt Water Damage and massive spalling around supports.

Reinforce damaged area per engineering specifications.

F.A.C.S.F.A.C.S.™™ Products Used Products Used

Aquawrap® BP-1 Structural AdhesiveAquawrap® 22-71 G-03 Aquawrap® 22-71 G-06 Structural Cloth

Copyright © 2002 Air Logistics Corporation

Page 45: The Luse Companies Pipe Repair Service

Freeway Sign Structure Tubing

Repair cracks in welds and reinforce the joints.

F.A.C.S.F.A.C.S.™™ Products Used Products Used

Aquawrap® 3” x 10’ RollsAquawrap® 3” x 25’ Rolls

Aquawrap® 4” wide Bear™ BP-1 Primer™

Aquawrap® 1” Backbone™

AL Foam Backer RodStricture Banding™

5/20 Epoxy Stick™

Copyright © 2002 Air Logistics Corporation

Page 46: The Luse Companies Pipe Repair Service

34" Diameter Naphtha Transmission Pipeline / 16 Foot Section / External Corrosion Repair

Page 47: The Luse Companies Pipe Repair Service

20" Diameter Natural Gas Transmission Pipeline / 16 Inch Repair / Girth Weld Corrosion Repair

Page 48: The Luse Companies Pipe Repair Service

28" Diameter Natural Gas Transmission Pipeline /20 Foot Section / Wrinkle Bend Damage Repair

Page 49: The Luse Companies Pipe Repair Service

8" Diameter Crude Transmission Pipeline /5 Foot Section / External Corrosion Repair

Page 50: The Luse Companies Pipe Repair Service

What is PowerSleeveWhat is PowerSleeve®®

Page 51: The Luse Companies Pipe Repair Service
Page 52: The Luse Companies Pipe Repair Service

Product Application

A 42” fabricated steel elbow. Rusted all the way through the wall (white spot.)

Surfaces sandblasted and sharp edges are “coved”.

Primer coat is applied.

AIR LOGISTICS CORPORATION

TM

Page 53: The Luse Companies Pipe Repair Service

Segment of PowerSleeve® is wetted out.

The first segment of PowerSleeve® is being applied.

Multiple layers of PowerSleeve® segments are applied around the elbow’s curve, over welds and even over the bell.

Product Application

AIR LOGISTICS CORPORATION

TM

Page 54: The Luse Companies Pipe Repair Service

Full strength is restored and all rusting is stopped.

Jobsite: Las Vegas, Nevada

Preparation Time: 1-1/2 Days

Installation Time: 1 day

Product Application

AIR LOGISTICS CORPORATION

TM

Page 55: The Luse Companies Pipe Repair Service

After the line was cleaned and the corrosion pits filled with a high compressive strength filler compound, PowerSleeve® was used to inhibit further corrosion and restore integrity to the piping system. Approximately 18 feet of piping plus an elbow were repaired.

Product Application

AIR LOGISTICS CORPORATION

TM

Page 56: The Luse Companies Pipe Repair Service

Acid vapors eroded a hole in the top of a storage tank. The hole was patched and the surrounding area reinforced with composite.

Page 57: The Luse Companies Pipe Repair Service

Failed Installation Failed Installation

Examples that Examples that

TLC can fixTLC can fix

Page 58: The Luse Companies Pipe Repair Service

This custom built repair clamp didn’t fit, so PowerSleeve® was used to build up the diameter of the line. The end rings on the clamp were installed over the built up area. A modification of this clamp could have taken days with costs in the thousands of dollars.

Page 59: The Luse Companies Pipe Repair Service

Attempted repair of leaking joint going into a wall. Surface cleaning was severely inadequate! Adhesion was minimal and caused the repair tofail. The composite was removed, the surface was properly prepared, and the job was done again. Hiring the best pipe repair team is critical for having a functional repair the first install.

A successful repair was completed.

Page 60: The Luse Companies Pipe Repair Service
Page 61: The Luse Companies Pipe Repair Service

Overview of the Aqua Wrap Install Procedure

Page 62: The Luse Companies Pipe Repair Service

Starting Surface Preparation

Page 63: The Luse Companies Pipe Repair Service

Finished Surface Preparation

Page 64: The Luse Companies Pipe Repair Service

Apply BP-1 Primer

Page 65: The Luse Companies Pipe Repair Service

GO-3 Roll of AquaWrap

Page 66: The Luse Companies Pipe Repair Service

Starting the Wrap

Page 67: The Luse Companies Pipe Repair Service

Spraying the Wrap with Water

Page 68: The Luse Companies Pipe Repair Service

Finished Wrap Prior to Stricture Application

Page 69: The Luse Companies Pipe Repair Service

Application of Stricture Banding

Page 70: The Luse Companies Pipe Repair Service

Perforating the Stricture Banding

Page 71: The Luse Companies Pipe Repair Service

Escape of Excess Water, Resin, & CO₂

Page 72: The Luse Companies Pipe Repair Service

Finished Pipe with Elbow

Page 73: The Luse Companies Pipe Repair Service

Photos from a recent TLC Install at a Power Generation Plant

Page 74: The Luse Companies Pipe Repair Service

59 Feet of Low Pressure Service Water Pipe with 36” diameter transitioning to 30” diameter

Page 75: The Luse Companies Pipe Repair Service
Page 76: The Luse Companies Pipe Repair Service

We can work in tight quarters

Page 77: The Luse Companies Pipe Repair Service
Page 78: The Luse Companies Pipe Repair Service
Page 79: The Luse Companies Pipe Repair Service
Page 80: The Luse Companies Pipe Repair Service

TLC wants to be your pipe repair “go to” team.

Page 81: The Luse Companies Pipe Repair Service

Mechanical Clamps for on-line Mechanical Clamps for on-line repair of active leaksrepair of active leaks

PLIDCOPLIDCO®®

Page 82: The Luse Companies Pipe Repair Service

Mechanical Leak Repair

Non-destructive on-line leak repair

Engineered Clamps and enclosures from ½” to 48”

Buna-N, Silicone, & Viton packings standard. Others available on request

ANSI rating to 10,000#

1000psi max operating pressure at -20° to +300° F. 1500 & 2000 psi can be furnished

Applications include pipe, flanges, valves, unions, heat exchangers

Repairs on water, steam, hydrocarbon, chemicals

Meets ASME Sec VIII & API 6H

Page 83: The Luse Companies Pipe Repair Service
Page 84: The Luse Companies Pipe Repair Service

Plidco ® Split+SleevePlidco ® Split+Sleeve

Pipe Repair that can be permanent or provide more flexibility on picking the outage to replace pipe

Page 85: The Luse Companies Pipe Repair Service

PLIDCO® Split+SleevePLIDCO® Split+Sleeve

Page 86: The Luse Companies Pipe Repair Service

PLIDCO® Split+Sleeve

Page 87: The Luse Companies Pipe Repair Service

Cross-section shows location of longitudinal packing and steel GirderRings which hold packing securely in place to prevent its displacement during installation.

Sectional view of circumferential Girder Rings show how they make displacement of packing impossible by securely supporting and holding it in place.

If installation is to be welded, simply fillet-weld ends, seal weld sides and seal weld nuts and studs

Clamp Construction Features Unique to Plidco ®

Page 88: The Luse Companies Pipe Repair Service

Buna-N packing is standard.Viton, Silicone and other materials are available upon request.

Standard body materials:-ASTM A106 Gr. C-ASTM A216 Gr. WCC

-ASTM A516 Gr. 70

-Standard bolting is ASTM A193 Gr. B7 with ASTM A194

-Gr. 2H nuts

Options:-Marine epoxy paint for corrosion protection-Hinges to ease with installation and handling

-Vents available per customer specifications

-Anodes for cathodic protection

-NACE MR0175/ISO 15156 compliant materials

Steel GirderRings prevent displacement & damage of seals during installation.

Additional features Plidco ® offers

Page 89: The Luse Companies Pipe Repair Service
Page 90: The Luse Companies Pipe Repair Service

Key products made by Plidco

Page 91: The Luse Companies Pipe Repair Service

Original Inventor and founder of Plidco ® last name was Smith. Thus known as a Smith+Clamp

Page 92: The Luse Companies Pipe Repair Service

A

B

C

D

A. Pilot pin (1/16” diam. stainless steel wire) goes down through center of force screw and cone, locates hole, guides cone point (D) to trouble spot.B. Steel packing force-screw. Turned with wrench, it forces point of cone into leaking hole. Additional wrenching pressure flattens cone into flat disc shape.C. Thrust washer. Permits force-screw (B) to turn without rotating cone.D. Pointed cone serves as leak packing.

Pressure rating up to 2000 psig working pressure, depending upon leak area and temperature.

Page 93: The Luse Companies Pipe Repair Service

Weld Cap or “Pumpkin Cap”

Benefits:• Safe, easy and fast permanent repair.• Can be welded while pipeline is in flow.• Meets D.O.T. requirements for permanent repair on sizes 4 inch and larger.

Page 94: The Luse Companies Pipe Repair Service
Page 95: The Luse Companies Pipe Repair Service

Hot Tapping Saddle Type

Page 96: The Luse Companies Pipe Repair Service

Another view of Hot Tapping Saddle Type

Page 97: The Luse Companies Pipe Repair Service
Page 98: The Luse Companies Pipe Repair Service
Page 99: The Luse Companies Pipe Repair Service
Page 100: The Luse Companies Pipe Repair Service
Page 101: The Luse Companies Pipe Repair Service

WELD+ENDS® COUPLINGJoins piping without special preparation of pipe ends

Page 102: The Luse Companies Pipe Repair Service

RISER TYPE WELD ENDSFor easier replacement of underwater risers

Page 103: The Luse Companies Pipe Repair Service
Page 104: The Luse Companies Pipe Repair Service

FLANGE REPAIR RING

Stops leaks in flange gaskets, on stream

Page 105: The Luse Companies Pipe Repair Service

Maximum temperature rating for the standard Flange Repair Ring is 700°F. Standard material is ASTM A516 Gr. 70 Plate, ASTM A193 Gr. B7 bolting and ASTM A194 Gr. 2H nuts. Other materials are available for higher or lower temperatures.NACE MR0175/ISO 15156 compliant materials should also be available.

Page 106: The Luse Companies Pipe Repair Service
Page 107: The Luse Companies Pipe Repair Service

SOLE MATES TYPE

Welded reinforcing and pressure containing sleeves

They are designed to reinforce non-leaking, weakened, dented or damaged pipelines. The part must fit snugly around the pipe when used for reinforcement applications. Gaps between the pipe and the sleeve, often caused by dents in the pipe, should be filled with a hard-setting grout. The sleeve must be butt-welded longitudinally but it is not necessary to seal-weld the circumferential ends. The line can remain on-stream. Moisture should be prevented from entering the ends of the sleeve.

When used for pressure containment, they must be fully seal-welded to the pipeline in addition to the longitudinal weld. The line may also remain on-stream but the pressure must be a safe level according to DOT regulation 192.713.

Page 108: The Luse Companies Pipe Repair Service

Plidco ® Repair Ell

 The RepairEll is fast and easy to install by simply bolting the halves over the leaking ell. Provision for venting or sealant injection is included. If sealant is necessary, your vendor will recommend the proper type.

Page 109: The Luse Companies Pipe Repair Service
Page 110: The Luse Companies Pipe Repair Service

Plidco ® Split+RepairEllPlidco ® Split+RepairEll

Page 111: The Luse Companies Pipe Repair Service

Plidco ® Split RepairEll

Page 112: The Luse Companies Pipe Repair Service
Page 113: The Luse Companies Pipe Repair Service

For Offshore Installation

Page 114: The Luse Companies Pipe Repair Service

This type of clamp is used to permanently seal leaks in a marine situation with marine epoxy coating, anodes fitted, zinc plated studs & nuts, and can be fitted with hinges and vents.

Page 115: The Luse Companies Pipe Repair Service

Additional Services provided by Plidco

Page 116: The Luse Companies Pipe Repair Service

CERTIFIED QUALIFICATION TRAINING

Page 117: The Luse Companies Pipe Repair Service

RECONDITION CLAMPS

BEFORE RECONDITIONING

Page 118: The Luse Companies Pipe Repair Service

AFTER RECONDITIONING

Page 119: The Luse Companies Pipe Repair Service

Typical Applications

Page 120: The Luse Companies Pipe Repair Service

Service water line Leak.Service water line Leak.

Page 121: The Luse Companies Pipe Repair Service

Leaking Coupling in an Electric Utility’s Substation Yard

Repaired using a custom designed PLIDCO® fitting

Page 122: The Luse Companies Pipe Repair Service

Retired Farm Tap Retired Farm Tap

Page 123: The Luse Companies Pipe Repair Service

Steel Pipe

A. Longitudinal Breaks up to 8”B. Circumferential Breaks

D. Small Pinhole Leaks, Splits and Corrosion CracksE. Broken Weld

Leaking Coupled Joints or Mechanical Joints

Page 124: The Luse Companies Pipe Repair Service
Page 125: The Luse Companies Pipe Repair Service
Page 126: The Luse Companies Pipe Repair Service
Page 127: The Luse Companies Pipe Repair Service
Page 128: The Luse Companies Pipe Repair Service
Page 129: The Luse Companies Pipe Repair Service
Page 130: The Luse Companies Pipe Repair Service
Page 131: The Luse Companies Pipe Repair Service

Plidco Over+Sleeve

Page 132: The Luse Companies Pipe Repair Service

THE ORIGINAL PIPE REPAIR TEAM

Page 133: The Luse Companies Pipe Repair Service

QUESTIONS

Page 134: The Luse Companies Pipe Repair Service

Your information requests receive our highest priority!

Randall Franklin John Provencher219.713.6036 [email protected] [email protected]