Specification Model: QX1401VD
QX1401VD Compressor Specification
1. DRAWING LIST
DRAWING NAME DRAWING No.
DIMENSIONS SKETCH QX14-WX
LEAD ROUTING QX14-DL
CHARACTERISTIC CURVE QX14-TX
RUBBER GROMMENT QX14-35
GROMMET SLEEVE QX14-36
DRIVER DIMENSIONS DA1510-WX
2. ACCESSORY PARTS LIST
ACCESSORIES NAME QUANTITY
DRIVER DA1510 1 piece
RUBBER GROMMENT 3 pieces
GROMMET SLEEVE 3 pieces
SCREW 3 pieces
NUT 3 pieces
SHIM 6 pieces
QX1401VD Compressor Specification
3. COMPRESSOR PARAMETERS
ITEMS DATA
Ou
tpu
t
Rated Voltage(V) 12
Rated Current(A) 10
Rated Power(W) 100
Max Power(W) 150
Output Frequency (Hz) 500
Speed(rpm) 6000
Inp
ut
Input DC12
Input Voltage(Vac) 9 -16
Rated Frequency(Hz) -
Power Factor -
Op
era
tio
n
Speedup Time(s) (0-max frequency) 30s
Speed adjustment accuracy 1%
Speed Scope(rpm) 2000-6000
Start Mode Open loop speedup
Speed Up/Down Mode Linear
Stop Mode Run to stop
Oth
er
Cooling Free air cooling
Noise <40dB
Operation Life >40000 Hours
QX1401VD Compressor Specification
4. COMPRESSOR SPECIFICATION
QX1401VD Compressor Specification
5. APPLICATION INSTRUCTION
6. BLDC CONTROLLER
The following electrical accessories are used based on power supplies and protection methods.
The individual specifications are listed in respective specification sheets
NO. ITEMS APPLIED NOTICE
1- Suction Gas
Temperature
Sufficient to keep the discharge gas temperature within the specified
range. The refrigerating circuit should be designed so that the suction
gas superheating is above 2℃ and liquid entry and compression are
prevented.
2- Starting Voltage
Min. Starting voltage is 9V. This refers to the voltage applied between
the terminals on the compressor, at starting balancing pressures below
0.6 Mpa.
3- Power Cycling
conditions
Min. Time interval between power on and off is above 5 minutes, with
running time above 3 minutes. Accumulated cycling times above
60,000.
DIVER NOTES
Controller Refer to the electrical schematics. The wire between the compressor terminal and the
controller should be heat resistant, temperature >105℃.
QX1401VD Compressor Specification
7. INSTALLATION & APPLICATION
7.1 GENERAL
1- Avoid installing the compressor in apparatus using refrigerants containing chlorine, Such as R12, R22, R502,
etc. Don't use filling devices that have been used for CFC or HCFC refrigerants before when filling the
refrigerant.
2- Don't use cleaning agents containing chlorine for cleaning circuits. Make sure that there is no residual chlorine
left if they have to be used. Special attention: The content of chlorine related substances in refrigerating
systems must be below 100ppm of the total refrigerant gas filled.
3- Use specified drying filters for HFC-134a only. Install the filters right after the sealing package is opened.
4- Tubing used in systems must be clean and free from residual oil left from the manufacturing process.
7.2 VACUUM
For building vacuum in the system the pumping should be made from both high and low pressure sides. The
vacuum should be below 0.35 mmHg.
7.3 REFRIGERANT
Refrigerant charging must be from the high pressure end (condenser side)
7.4 RUBBER PLUGS
The compressors are filled with high purity Nitrogen at 0.01 to 0.05 Mpa (Gage pressure) at the factory and the
tubes are sealed with rubber plugs and thermal shrinking plastic tubes. The plug in discharge tube should be
removed first to prevent oil from bursting out.
7.5 IMPURITY
No soldering agent, dusts, or other substances are allowed to get into the system when soldering the compressor
to tubing. Solder material should be low melting temperature to avoid oxidization on tunings.
QX1401VD Compressor Specification
7.6 COMPRESSOR MOUNTING
Use the rubber grommets from factory. Tilting angle should be not more than 5°
7.7 COMPRESSOR OPERATION
Compressor mustn’t be started until they are installed into system with refrigerant fulfilled. No running should be
made when compressors are open to air. Allow for min. 3 minutes for internal pressure to be balanced between 2
starting.
7.8 TUBE CLEANING
Clean tubing in order to prevent metal chips, fibers and impurities from the system when installing compressors.
Install a 100 mesh metal filter in the tubing.
7.9 REFRIGERATION OIL
Refrigeration oil RL-32H,150TD or equivalent performance oil with HFC-134a is used for high reliability. R134a
has excellent thermal stability and wear resistance. Other oil is NOT allowed to be added into system.
7.10 REFRIGERANT
Use high-purity HFC-134a (above 99.9%, or above 99.95% if possible) .
7.11 GENERAL REQUIREMENTS
1- Compressors should be installed into refrigeration circuits within a year after they are manufactured.
2- Install compressors into refrigeration circuits within 30 minutes after breaking sealing to prevent moisture from
getting into the compressors.
3- Never pump vacuum in compressors alone.
4- Never make idle runs on compressors.
5- Do not power up compressors under vacuum conditions.
6- Avoid crash or any impact when compressor in installed.
7- Compressor should be stored with good ventilation, free from the existence of corrosive gas. Do not store
compressor at the same location for corrosive stuffs containing acid or alkaline. Relative humidity should be
lower than 80%.
QX1401VD Compressor Specification
8. EXTERNAL DIMENSION (QX14-WX)
QX1401VD Compressor Specification
9. GROMMET & SLEEVE (QX14-36)
10. RUBBER GROMMET (QX14-35)
QX1401VD Compressor Specification
11. CHARACTERISTIC CURVE (QX14-TX)
Remark: Condensation Temperature:38℃
Remark: Condensation Temperature:38℃
Controller DA1510 Instruction
12. CONTROLLER
Controller DA1510 is specifically designed for variable frequency compressor with
low voltage (DC 12V input) and low power.
※ Multiple speed control methods without position sensor.
※ Operation temperature is -20℃~+45℃.
※ Operation smoothly, low noise.
※ Small installation footprint.
※ All components are industrial level, key components, e.g. IC, capacitor, power MOSFET etc. are all global
famous brand.
13. CONTROLLER DATA
Type DA1510 D A 151 0
Definition Driver for Variable
Frequency Driver DC 12V
Power:
150W
IP:
0:IP00
14. INTERFACE
14.1 Diagram
Controller DA1510 Instruction
14.2 Interface
Remarks: The wiring shall follow the above instructions; otherwise failure will be caused.
No. Description SPEC
1 EN Switch EN, Enable terminal, reservation for EN. P2500J-02
2 PWN speed control terminal (0~5V,1K~10KHz). P2500J-02
3 Fault alarm compressor failure alarm, high level-normal, low
level-failure. P2500J-02
4 Connecting lines (Any direction connecting the compressor).
5 TTL communication port P2500J-03
6 0~5V to adjust the speed. P2500J-02
7 Terminals for potentionmeters with 50kohm to adjust speed. P2500J-02
8 Control program edit input socket
9 Green LED
10 Red LED
A Positive weir Power “ + ” 1015 16# Red
B Negative weir Power “ - ” 1015 16# Black
Controller DA1510 Instruction
15. CONTROLLER DIMENSIONS (DA1510-WX)
Unit: (mm)
Controller DA1510 Instruction
16. OPERATION INSTRUCTION
6.1 Analog speed control is default speed control mode. The mode can be temporarily changed
thru communication software provided, but the changed mode can NOT be stored in the product.
6.2 Under the communication control mode, the user can control the compressor speed thru
setting-up “Control Instruction” and “Speed Setup”. The communication protocol is MODBUS RTU.
6.3 Under analog speed control mode, the higher corresponding speed will have priority among
analog voltage, potentiometer and PWM.
1- Analog Voltage Mode - the relation between the voltage and the speed are linear relation: 0V-0.5V, compressor
stops. ≥0.7V, compressor starts to run. 0.7V-5V, corresponding speed is 2000rpm - 6000rpm
2- PWM Mode - the frequency and the speed is linear relationship: 300-500Hz, compressor stop. 1000Hz,
compressor starts to run.1000-10000Hz, corresponding speed is 2000rpm – 6000rpm.
3-Potentiometer Mode – 50KΩ, compressor stops. 30KΩ-0KΩ, corresponding speed is 2000rpm – 6000rpm.
6.4 Red/Green LED to indicate the status of the driver.
17. Definition of Red/Green LED indicator:
Driver Status Green LED Red LED
Standby Blink (On - 0.25s, Off - 0.25s) Off
Motor Failure Off
Blink N times (On - 0.25s, Off -0.25s), then off
2s, repeat as above cycle (N means Error
Number, seen below definition.)
Operating Normal Green LED and Red LED blink alternately (On - 0.25s, Off - 0.25s)
Controller DA1510 Instruction
18. Error Number (N):说
Number
of Red
LED blinks
Failure Description
1 Short or output
over-current
The driver will alarm over-current failure when peak value of output
current is larger than 30A, and stop the output. The driver will restore in
3minutes. The driver will be locked if there are more than 7 times
over-current protection in 1 hour. The alarm will be eliminated after
re-power-on.
2 Motor Stall The driver will stop the output and alarm when the motor is stalled. And
driver will try to restore to run 3 minute later.
3 Temperature
Sensor Failure
The driver will not work when disconnecting of temperature sensor is
detected.
4 MOSFET Over
temperature
Stop the output when the temperature of MOSFET goes up to 105℃.
Restore the output when the temperature of PIM goes down to 85℃.
When over-temperature protection happens, the driver stops the output
and then will try to restore in 3 minutes.
5 V_BUS
Low Voltage
The driver will alarm and stop output when V_BUS is lower than 8.2V and
restore when V_BUS is higher than 9V and last more than 3minutes.
6 V_BUS
Over Voltage
The driver will alarm and stop the output when V_BUS is higher than 17V
and restore when V_BUS is lower than 16V and last more than 3minutes.
7 Lack-phase The driver will alarm and stop the output if disconnecting between the
driver and compressor. The driver will try to restore in 3 minutes.