28
We know flow. Acoustic Flow Measurements and their Applications ®

Hydro vision brochure_acousticflowmeasurement_en

  • Upload
    carotek

  • View
    105

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Hydro vision brochure_acousticflowmeasurement_en

We know flow.

Acoustic Flow Measurements and their Applications

®

Page 2: Hydro vision brochure_acousticflowmeasurement_en

• • •

• •

• • •

• • •

Q-Eye Radar MT

••

•• •

• •Pa

ge

Rive

rs

Chan

nels

Hyd

ro P

ower

Wat

er S

uppl

yW

aste

Wat

erIn

dust

ry

24

Q-Eye PSC / PSC MT 19

Product Guide

Q-Eye M III 19

AquaProfiler® mobile

ReVision® 14

Ductus TT COHP 12

Ductus TT 11

Kanalis TT MT 9

Fluvius TT 7

You can find HydroVision flow meters working all around the world.

Our flow meters are manufactured in Germany to assure only the best quality in design and product.

In order to be closer to the customer, products for the Asian market are also manufactured in Singapore.

AquaProfiler®

stationary

Water Level

22

20

20

Page 3: Hydro vision brochure_acousticflowmeasurement_en

Vision

Monitoring water is becoming more and more important. Resources, particularly drinking water are extremely limited. In areas requiring irrigation, especially in very dry districts, man is already fighting to make good use of the last drop.

Without doubt, the acoustic discharge measurement has enhanced its prestige. It is used as a fundamental information for water management in the field of hydrology, for the control of processes in the field of hydro power as well as for water supply, industry and waste water applications.

The acoustic principle has become a growth driver for flow meters. More and more users have already begun to appreciate the advantages of contact free measurements. With a comprehen-sive range of products and solutions we can determine flow in various applica-tions. Accuracy and reliability are given top priority. HydroVision products owe their quality to rigorous testing under laboratory conditions and their con- tinuous development. We are not

satisfied until our instruments meet the required accuracy under real field conditions.

HydroVision’s broad knowledge in the area of acoustic flow measurement is reflected in our product range for stan-dard applications. It becomes even more apparent when complex tasks have to be solved.

HydroVision is committed in equal mea-sure to consulting, delivery quality, service and support.

Water is a valuable commodity, with which we feel connected in a special way. HydroVision is passionate about its products and can look back on many years of experience. HydroVision starts where others stop. We are continually developing our product range to stay one step ahead. This enables us to reliably solve all your measuring tasks.

We know flow.®

Dr.-Ing. Jürgen SkripalleCEO

3

Page 4: Hydro vision brochure_acousticflowmeasurement_en

p. 22 AquaProfiler®

In this product overview we describe the various applications for our instruments. A vast amount of applications can be solved using acoustic flow measurement. HydroVision is at the forefront of “State of the Art” and future development.

Our measurement instruments can be used everywhere where there is flowing water. For example rivers, channels or pipes – we measure everywhere.

p.6

p. 10 Hydro Power

Rivers

We measure everywhere.

4

Page 5: Hydro vision brochure_acousticflowmeasurement_en

When sound propagates through water, pressure fluctuations can be detected. They travel through the water, the channel or the pipe as sound waves.With our instruments it is possible to record these ultrasound waves.

Depending on the measurement technique applied, we detect the Transit Time with and against the flow direction. For other applications we use the Pulse Doppler effect. Here our instruments record the change of the wave length reflected by a particle in the flow.

Channels

Waste Water

Water Supplyp. 14

p. 18

p.8

We measure everywhere.

Irrigationp. 22

5

Page 6: Hydro vision brochure_acousticflowmeasurement_en

Rivers

Numerous rivers intersect our landscape from small brooks up to huge river networks. Some of them form a natural border between two countries.

At all times man has preferred to live in river areas. Clear water, the possibility to use the river for trans-port, generating power from water and the scenic beauty are amongst the reasons. However, our actions have more and more influence on water quantity and quality. In many regions taking water for irrigation or as drinking water are the reasons. More than half of all big rivers around the world have been polluted during the course of time.

Observations of water levels have been used since ancient times, systematic flow measurements go back to the middle of the 19th century. This historical data has been used as the basis for various applications, for example for flood protection and flood forecasting. They also form the foundation for the design of hydro-engineering constructions. In recent years the acoustic flow measurement has established itself as the standard method for measurements on many hydrological stations. With this almost contact free technology data can be recorded continuously and it provides 24/7 monitoring.

6

Page 7: Hydro vision brochure_acousticflowmeasurement_en

TD-200/5 TD-28/18TD-200/8TD-200/18

TD-15/17

Fluvius TT ECM IETravel time system with digital signal processing

Specifications

Acoustic Paths: 1 - 8, length 1 - 1000 m

Frequency: 15, 28, and 200 kHz

Accuracy: ± 2% (typical)

Display: 4 lines, 20 characters

Datalogger: internal,

sampling interval user selectable

Communication: RS-232, MODBUS, Ethernet, USB

Inputs: max. 8 x 4-20 mA

Outputs: max. 4 x 4-20 mA

2 x Relay, 2 x Pulse

Power Supply: 85-264 VAC (50-60 Hz) or 24 VDC

Battery Backup: integrated, 2 Ah

Enclosure: Aluminium, wall mounted

Specifications

Type Frequency Beam Width Dimensions

TD-15/17 15 kHz 17° (-3dB) Ø 368 mm Height 121 mm

TD-28/18 28 kHz 18° (-3dB) Ø 183 mm Height 142 mm

TD-200/5 200 kHz 5° (-3dB) Ø 340 mm Height 170 mmTransducers

ProductsThe range of application for Fluvius TT runs from small waterways to huge river systems with high suspended solids. By means of acoustic transmission a coded signal is sent through the water and the transit time is calculated providing the speed of river flow. When an acoustic wave propagates in water, part of the energy is damped by friction and suspended solids. This procedure is frequency-related. The higher the frequency, the bigger the damping. For wider distances we use low frequencies as they allow for a considerably better receiver signal.

TD-15/17

TD-28/18

TD-200/5 (ball-shaped assembly)

Commonly used transducer frequencies for various path lengths and sediment loads.

10000

500040003000

2000

1000

500400300

200

100

5040

30

20

10

Sediment load in g/m3

1 2 3 4 5 6 7 8 9 10 20 30 40 50 100 200 300 400 500 1000

Acoustic path length in m

7

Page 8: Hydro vision brochure_acousticflowmeasurement_en

Channels

Channels are artificially created waterways used for shipping, transportation, irrigation, drainage and for cooling water extraction of power plants.

A further important use is the transportation of water used for the supply of drinking water. Here the focus lies on detecting water loss at an early stage; some- times it is difficult to detect small leakages.

Our instruments measure precisely and reliably in order to prevent long term water losses.

Crossed-path system, Irrigation channel

8

Page 9: Hydro vision brochure_acousticflowmeasurement_en

Kanalis TT MTTravel time system with digital signal processing

ProductsSpecifications

Acoustic Paths: 1 - 10 (more upon request)

Channel Width: 1 - 30 m

Frequency: 200 kHz

Accuracy: ± 2% (typical)

Display: 4 lines, 20 characters

Datalogger: 16GB MicroSD card

Communication: RS485, MODBUS (RS232 or RS485)

WLAN, GPRS, Ethernet 10/100 Mbps

Inputs: max. 4 x 4-20 mA, 2x digital

Outputs: max. 4 x 4-20 mA

4 x Relay, 2 x digital

Power Supply: 85-260 VAC (48-60 Hz) or 9-36 VDC

Enclosure: ABS, wall mounted

Specifications

Type Frequency Beam Width Dimensions

TD-200/8 200 kHz 8° (-3dB) Ø 218 mm Height 109 mmTD-200/18 200 kHz 18° (-3dB) Ø 140 mm Height 70 mm TD-200/18 200 kHz 18° (-3dB) Ø 140 mm Atex Height 70 mm

Mounting AssemblyStandardized mounting devices for any kind of channel ge-ometry like rectangular, trapezoid or natural river banks are available. The flow optimized design protects the transducers against moving objects suspending in the flow stream. It also provides room for connections and protective conduits.

Transducers

TD-200/8

In its most basic form, the system operates with a single pair of transducers.

However, it relies upon a relatively stable velocity profile, essentially unaffected by changes in the rela-tion between water level and flow.

The main flow has to be paral-lel to the bank. The relationship between measured velocity and

flow is established by hydrometric

calibration.

In rivers there is a high risk of cross flow. Its intensity depends mainly on the river’s geometry and if there is an upstream bend in the river.

Although the cross flow does not influence the quantity of the flow, it may affect the mea-sure-ment, a second pair of trans- ducers will be necessary.

By crosswise arrangement of four transducers, effects of changing flow direction can be eliminated.

An even more accurate flow mea-surement can be obtained with systems using several planes.

The measured result can be further improved by using a multi path system layering each of the acoustic paths in parallel planes one above the other. This negates having an expensive hydrometric calibration. This type of system is suitable for applications with large water level fluctuations, reverse flow or a ver-tical velocity distribution outside the theoretical normal.

Single-path system Crossed-path system Multi-path system

TD-200/18 TD-200/18 Atex

9

Page 10: Hydro vision brochure_acousticflowmeasurement_en

Hydro Power

Hydro power is an important source of energy which contributes to supplying power to the earth’s popula- tion. Today, hydro power plants deliver approximately 3,5 per cent of electric energy generated worldwide. Their share in power generation from renewable re-sources comes to 18 per cent. In the future this share will continue to grow, as resources of fossil fuels are depleted.

The hydro electric performance depends essentially on the usable altitude difference between upper reservoir and lower reservoir, and hence the flow. In order to use the “fuel” water in an optimal way, this flow has to be monitored without any interruptions.

4 planes crossed

according to IEC 41 / ASME PTC 18

10

Page 11: Hydro vision brochure_acousticflowmeasurement_en

*)

oth

er r

ang

es u

po

n r

equ

est

Specifications

Frequency: 200 kHz 120 kHz 120 kHz

Beam Width: 18° (-3dB) 10° (-3dB) 10° (-3dB)

Configuration: IEC41 / ASMEPTC 18 IEC41 / ASME PTC 18 IEC41 / ASMEPTC 18

Pipe Diameter: 1,0 m to15 m 0,3 m to 15 m 0,3 m to 15 m

Pipe Wall Thickness:

- welding socket - n.a. up to 40 mm up to 40 mm

- thread - n.a. up to 70mm up to 70 mm

Pressure Rate: 60 bar *) 60 bar *) 60 bar *)

Material: Stainless Steel / Polyamid Stainless Steel Stainless Steel

Cable: twisted pair with shield twisted pair with shield twisted pair with shield

Cable Length: max. 1000 m max. 1000 m max. 1000 m

Temperature Range: -10° to 60°C -20° to 60°C -20° to 60°C

Dimensions: 320 x 100 x 70 mm Ø 1 1/2“ Ø 1 1/2“

(LxWxH) Length: 181 mm Length: 194 mm

Installation: From the inside When pipe can be dewatered for installation.

Designed to allow removal of the entire transducer for repair, replacement or cleaning without the need to dewater the pipe.

Ductus TT ECM IETravel time system with digital signal processing

For pipes with a diameter of more than half a meter, acoustic flow measurement systems have long established themselves as a reliable and convenient measurement method. Measurements in several planes are a recommended method to determine the efficiency of the turbine without the need for calibration meeting the latest international standards. Fixed installed equipment form the basis for verifying the efficiency. A deterioration of efficiency can be detected right away and therefore corrections can be initiated at an early stage.

Internal Mount Feedthrough 45° Feedthrough 35°

Products

Specifications

Acoustic Paths: 1 - 8

Accuracy: ± 0,5% with 8 paths

Range: ± 20 m/s

Display: 4 lines, 20 characters

Datalogger: internal,

sampling interval user selectable

Communication: RS-232, MODBUS, Ethernet, USB

Inputs: max. 8 x 4-20 mA

Outputs: max. 4 x 4-20 mA

2 x Relay, 2 x Pulse

Power Supply: 85-264 VAC (50-60 Hz)

or 24 VDC

Battery Backup: integrated, 2 Ah

Enclosure: Aluminium, wall mounted

Transducers

A variety of transducers is available - depending on the requirement

Internal mount assemblies which can be fixed directly to the wall. The transducers are aligned by rotating them in their mounting into a predefined position and then fixed in place by tighteningFeedtrough assemblies for installation through exposed penstock walls with access to the interior and exterior of the penstock flow meter section.

11

Page 12: Hydro vision brochure_acousticflowmeasurement_en

A further area of application is the detection of burst pipes. Here, at least two systems have to be permanently installed in the pipelines to be monitored. Because of the accuracy of our products even small leakages can be detected instantaneously.

Transducer

Ductus TT COHP-IETravel time system with digital signal processing

Specifications

Acoustic Paths: 1 - 8

Accuracy: ± 0,5% with 8 paths

Range: ± 20 m/s

Pipe Diameter: 0,3 - 10 m

Pipe Wall Thickness: max. 100 mm (steel)

Display: 4 lines, 20 characters

Datalogger: internal,

sampling interval user selectable

Communication: RS-232, MODBUS, Ethernet, USB

Inputs: max. 8 x 4-20 mA

Outputs: max. 4 x 4-20 mA

2 x Relay, 2 x Pulse

Power Supply: 85-264 VAC (50-60 Hz)

or 24 VDC

Battery Backup: integrated, 2 Ah

Enclosure: Aluminium, wall mounted

Advantages of Clamp-On Systems

A flow meter using clamp-on

transducers makes measuring

flow non-intrusive and easy from

the outside of the pipe.

The transducers are installed with

little technical effort and without

process interruption on the

pipeline.

Rotationally symmetric flow profiles

can be determined with a single

acoustic path; non-symmetric

profiles require the use of several

acoustic paths.

Clamp-On with 8 acoustic paths

Specifications

Pipe Diameter: 0,3 m to 15 m

Pipe Wall Thickness: up to 100 mm (steel, plastic, glass fiber)

up to 40 mm (concrete)

Frequency: 200 kHz

Beam Width: 8° (-3dB)

Material: Stainless steel, Polyamid

Dimensions: 300x120x100mm

Mounting: non intrusive,

from the outside of the pipe

12

Page 13: Hydro vision brochure_acousticflowmeasurement_en
Page 14: Hydro vision brochure_acousticflowmeasurement_en

Water Supply

Although there is enough water on earth and it is not consumed but merely used, drinking water starts to get short. The uneven distribution of water amongst the regions, the rising population and our carelessness leads to a shortage of fresh drinking water.

In the future more and more pipelines for drinking water will be built all over the globe. In order to operate huge and complex pipe networks efficiently, flow measurement will be necessary.

ReVision® with

5 layers

14

Page 15: Hydro vision brochure_acousticflowmeasurement_en

ReVision®

Fully integrated metering solution

with 10 acoustic paths

In the unlikely event that a transducer should fail, the ReVision® can be programmed to automatically compensate

for the loss in path information with a little reduced accuracy in addition to advising the operator that an alarm

is present. The transducer housings are separate from the transducers, allowing the transducers to be changed

without special tooling and without shutting down the process.

Transducer Replacement

Products

ReVision®

transmitter

The ReVision® flow meter is a fully integrated metering solution with up to 10 acoustic paths for liquid fluids. It is

a new entry in the HydroVision family of high accuracy acoustic metering products. It increases your profitability

with exceptional repeatability and linearity throughout the flow range. Due to the patented velocity profile

compensation no flow straightener is needed and no on-site calibration is required.

Specifications

Acoustic Paths: 1 - 10 (20 transducers)

arranged in max. 5 planes, crossed

Flow: bi-directional

Accuracy: up to < ± 0,15 %

Range: 0 to ± 20 m/s (0 to ± 66 ft./s)Repeatability: < ± 0,02 %

Zero Stability: < 1 mm/sPressure Range: PN6, PN10, PN16Flanges: EN1092-1, ANSI Meter Sizes: DN 200 (8“) to DN1200 (48“) > DN 1200 (48“) cold tapping into an existing pipelineCommunication: RS-485, MODBUS, WLAN, GSM/GPRS

Ethernet 10/100 Mbps Inputs: max. 4 x 4-20 mA, 2 x digital

Outputs: max. 4 x 4-20 mA

2 x Pulse, 4x Relay

Power Supply: 85-260 VAC (48-60 Hz) or 9-36 VDC

Enclosure: ABS, wall mounted

DN Inch Length

200 8“ 400 mm

250 10“ 450 mm

300 12“ 500 mm

350 14“ 550 mm

400 16“ 600 mm

450 18“ 700 mm

500 20“ 750 mm

600 24“ 900 mm

700 28“ 1100 mm

750 30“ 1150 mm

800 32“ 1200 mm

900 36“ 1400 mm

1000 40“ 1500 mm

1050 42“ 1600 mm

1100 44“ 1700 mm

1200 48“ 1800 mm

Meter Sizes

15

Page 16: Hydro vision brochure_acousticflowmeasurement_en

ReVision®

Concept Innovation

Space constraints and/or appropriate

application configurations lead to

complex industrial pipe flows which

contain elbows, tees and/or other

disturbing and non-uniform elements.

This leads to difficulties in install-

ing flow meters at a recommended

“optimum” location, which is defined

by a minimum distance upstream or

downstream of known disturbances

like an elbow or pump where a fully

developed velocity profile is present.

Even with multiple flow sensors, there

may still be a significant error which is

known as the profile factor.

flow meter after a 90° elbow

flow meter after two out of plane changes in flow direction

Prior knowledge of the profile factor can be used to correct the velocity measurements made by flow sensors

to a true spatially averaged velocity. The ReVision® acoustic system provides detailed information on the

flow velocity profile and an accurate measurement of the flow rate can be achieved by rebuilding the whole

flow velocity profile across the pipe using predetermined conduit configuration parameters and correction

factors.

Asymetric and Swirls Compensation

Swirl is normally generated by two or more out of plane changes in flow direction (e.g. one elbow/tee that

goes from vertical to horizontal followed by an elbow/tee that changes the direction of flow in the horizon-

tal plane). Swirl is present to some extent in almost every application and can generate significant trans-

verse velocity components plus it takes a long distance to dissipate. If the swirl is not centred, it can cause

significant errors. Thanks to the predetermined conduit configuration parameters and correction factors,

the flow meter measurement accuracy is kept when asymmetric profiles and swirls are present in the pipe.

Flow meters are also sensitive to velocity profiles where there is a large rotational component (swirl).

16

Page 17: Hydro vision brochure_acousticflowmeasurement_en
Page 18: Hydro vision brochure_acousticflowmeasurement_en

Installation in manhole

Waste Water

Drinking water is not the only area requiring flow measurement. The disposal and cleaning of waste water is of equal importance. Waste water contains a multitude of organic sub-stances which used to be dumped directly into the soil or the nearest river. As awareness has increased, most discharges are now treated to assure long term sustainability. The contamination of surface waters has now been reduced and the oxygen content could be increased once again. Due to the advance of waste water treatment around the world nature was able to regenerate in many places. Today’s civilization is un-thinkable without functioning water treatment plants. Modern plants are highly complex systems.

They consist of channels for waste water flow, facilities for waste water collection and clarification plants. HydroVision can complete flow measurements in all of these areas.

18

Page 19: Hydro vision brochure_acousticflowmeasurement_en

Q-Eye M IIIportable Pulse-Doppler system

Specifications

Sensor: 1 x velocity

1 x water level

Frequency: 1 MHz

Range: velocity ± 5,3 m/s

water level 0,04 - 1,3 m

expandable via optional

hydrostatic sensor

Accuracy: ± 1% of measured value

for v and h

± 0,25% for value h (hydrostatic)

± 2% for flow

Cable Length: max. 80 m

Display: 3 lines, 16 characters

Keyboard: 3 keys

Datalogger: 4MB (internal)

Communication: RS-232

Outputs: 1 x Pulse

Power Supply: battery operation

6 x 1,5 V (D-size)

or rechargeable battery

Approval: ATEX (option)

Enclosure: POM (Polyoxymethylen)

Q-Eye M III is your choice for mobile applications.

The long lifetime of approximately 70 days with

a measuring interval of 5 minutes, as well as the

small and robust housing make it the perfect tool

for temporary operations. In addition to water level

and flow, the signal quality, battery voltage and the

calculated flow are also stored inside the data logger.

Mouse Type

Insertion Type

Mouse Type

ProductsFor sewage-treatment plants flow measurements are primarily installed for internal reasons, for example to control specific plant components with flow dependency or for controlling additives. International regulations, for example the EU-Directive for handling municipal waste water, require a continuous surveillance of waste water flow. Defective flow measurements on sewage-treatment plants can therefore influence their operation, but there can also be legal or environmental consequences.

Q-Eye PSC / PSC MTstationary Pulse-Doppler system

Specifications

Sensor: 1 x velocity 1 x water levelFrequency: 1 MHzNumber of Cells: Q-Eye PSC: mean value Q-Eye PSC MT: max. 18 cellsRange: velocity ± 5,3 m/s water level (ultrasonic) 0,04-1,3 m expandable via external 4-20 mA sensorAccuracy: ± 1% of measured value for v and h (ultrasonic) ± 2% for flowCable Length: max. 80 mDisplay: 4 lines, 20 characters Keyboard: 4 keysDatalogger: 16GB MicroSD card Communication: RS-485, MODBUS, WLAN, GPRS Ethernet, 10/100 MbpsInputs: max. 4 x 4-20 mA, 2x digitalOutputs: max. 4 x 4-20 mA 4 x Relay, 2 x PulsePower Supply: 85-260 VAC (48-60 Hz) or 9-36 VDC Approval: ATEX (option)

Enclosure: ABS, wall mounted

19

Page 20: Hydro vision brochure_acousticflowmeasurement_en

ProductsIn some applications it is an advantage to have a non-contact measurement. By combining both radar and water level transmitter, they provide a revolutionary approach to open channel and sewer flow monitoring. Combined are pulse wave radar velocity sensing technology with ultrasonic pulse echo level sensing to measure open channel flows.

Q-Eye Radar MTPulse-Wave FFT Technology

Water LevelCompact Ultrasonic Level Transmitter

SpecificationsSensor: 1 x velocity 1 x water level (optional)Frequency: 24 GHzV-Sensor: bi-directionalBeamwidth: 10° at -3dBRange RV11: ± 0,05 m/s (0,16 ft/s) to ± 15 m/s (50 ft/s)Resolution: 1 mm/s; min. wave height 3mmDisplay: 4 lines, 20 characters Keyboard: 4 keysDatalogger: 16GB MicroSD card Communication: RS-485, MODBUS, WLAN, GPRS Ethernet 10/100 MbpsInputs: max. 4 x 4-20 mA, 2x digitalOutputs: max. 4 x 4-20 mA 4 x Relay, 2 x PulsePower Supply: 85-260 VAC (48-60 Hz) or 9-36 VDC Approval: ATEX (option)Enclosure: ABS, wall mounted

Due to patent rights, not for sale in the USA.

Specifications

Frequency: 60 kHz for WLU3702

80 kHz for WLU3802

80 kHz for WLU3902

Range: 0,2 - 4 m for WLU3902

0,25 - 6 m for WLU3802

0,35 - 8 m for WLU3702

Accuracy: ± 0,2% of measured value

Cable: Ø 6-12 mm

Display: 1 line (option)

Datalogger: internal,

10.000 sets of data (option)

Power Supply: 24 VDC

Approval: ATEX (option)

Mounting: 11/2“ BSP/NPT for WLU3902

2“ BSP/NPT for WLU3802

2“ BSP/NPT for WLU3902

Enclosure: Flame retardand plastic or

powder coated aluminum

Q-Eye Radar MT is an extremely versatile flow mea-

sure- ment system designed for continuous operation

and suitable for measurements of flows not only in

rivers and open channels, but also in municipal waste-

water and storm water sewers. Compact construction

combined with the contact-free measurement princi-

ple enables an easy installation and use. The maximum

permissible installation height above the surface is 30

m. For waste water applications we suggest 10 m.

The ultrasonic depth sensor operates by energizing a

piezoelectric transducer with an electronic pulse. This

pulse creates a pressue wave that travels to the flow

surface where a portion returns to the transducer. Our

transmitter offers the best in liquid measurement. It is

easy to install, eliminates maintenance caused by sen-

sor fouling and your personnel do not get in contact

with the fluid during installation.

20

Page 21: Hydro vision brochure_acousticflowmeasurement_en
Page 22: Hydro vision brochure_acousticflowmeasurement_en

AquaProfiler®

AquaProfiler®

The AquaProfiler® is a line of acoustic flow meters for permanently installed and portable applications. The AquaProfiler® precisely measures water velocities in open channels and pipes.

With its high accuracy and competitive cost, the Aqua-Profiler® is a perfect choice for long-term real-time monitoring or to obtain instantaneous measurements where time savings are an important aspect. It uses ad-vanced Doppler technology to establish the velocity in many separate space points (cells) along the measure-ment axis and develop the flow profile.

22

Page 23: Hydro vision brochure_acousticflowmeasurement_en

Permanently installed applicationsThe AquaProfiler® MT and MC are profiling instruments designed for in-situ installations. With the 2-dimensional velocity sensor and a resolution of max. 64 cells, the systems are the best choice for flows affected by variable backwater, sluggish, slow moving flows, ice-affected flows, tidal flows and flows where flow reversals may occur. Combined with an integral pressure sensor for determining the depth, the meter is using a numerical model for averaged velocity in the entire cross section and the continuity equation to calculate flow. Alternatively, the index-velocity method can be used, as the sensor gives an index velocity for a significant part of the flow which can easily be related to the mean velocity of the cross section.

Specifications

Sensor: 1x velocity

1x water level

Display: 4 lines, 20 characters

Datalogger: 16GB MicroSD card

Communication: RS485, MODBUS (RS232 or RS485)

WLAN, GPRS, Ethernet 10/100 Mbps

Inputs: max. 4 x 4-20 mA, 2x digital

Outputs: max. 4 x 4-20 mA

4 x Relay, 2 x digital

Power Supply: 85-260 VAC (48-60 Hz) or 9-36 VDC

Enclosure: ABS, wall mountedAquaProfiler® MTstationary Pulse-Doppler system

2L

AquaProfiler® MCstationary Pulse-Doppler system

Specifications

Display: 4 lines, 20 characters

Datalogger: internal,

sampling interval user selectable

Communication: RS-232, MODBUS, Ethernet

Inputs: max. 4 x 4-20 mA

Outputs: max. 8 x 4-20 mA

2 x Relay, 2 x Pulse

Power Supply: 85-264 VAC (50-60 Hz) or 12 VDC

Enclosure: Aluminium, wall mounted

Dimensions: 265x241x104 mm

Mouse Typevertical and horizontal applications

*) f

or

par

ticl

e co

nce

ntr

atio

n o

f 50

to

150

0 p

pm

2L 2XL

Frequency: 2 MHz 600 kHz

Max. number of cells: 64 64

Max. profiling range: 0,25 to 20 m *) 0,5 to 120 m *)

Min. cell size: 0,25 m 0,5 m

Max. blanking: 0,25 m 0,5 m

Range: velocity ± 8 m/swater level hydro-static: 0-10 m

velocity ± 8 m/swater level hydro-static: 0-10 m

Temperature sensor: -5°C to 40°C

Accuracy: for value v: 0,5% FS ± 0,25 cm/sfor value h: 0,1% FSfor value t: ± 0,1°C

Max. cable length: 80 m 80 m

Dimensions: 350x140x65 mm 450x140x90 mm

Transducers

2L 2 XL

23

Page 24: Hydro vision brochure_acousticflowmeasurement_en

Portable ApplicationsThe AquaProfiler® M and M-PRO are light, hand-held systems designed to simplify the entire measure-ment process in rugged field environments such as shallow waters suitable for wading. The portable flow meters provide instantaneous velocity and depth measurements at each measurement vertical and automatically calculate total flow based on ISO methods. Real-time velocity graph and otheruseful options and accessories make it the best solution on the market.

AquaProfiler®-Mpoint velocity

AquaProfiler®-M Provelocity profiling

Specifications

Sensor: 1 x velocity 1 x water level 1 x temperatureFrequency: 6 MHzRange: velocity 0-3 m/s water level (hydrostatic) 0 - 4 m temperature 0°-50°C Accuracy: ± 1% of measured value for value v ± 0,1% for value h (hydrostatic) ± 0,3°C for temperatureCable: 5 or 10 m from sensor to backpackPower Supply: rechargeable battery pack LiFePO4 6000 mAhOperation Time: +24 hours (sensor & transmitter) tablet depending on model Dimensions: Ø 45mm, length: 290 mmAccessories: backpack to fit all components

SpecificationsSensor: 2 x velocity 1 x water level 1 x temperatureFrequency: 2 MHzRange: velocity ± 5 m/s water level (hydrostatic) 0 - 4 m temperature 0°-40°C Accuracy: ± 1% of measured value for value v ± 0,1% for value h (hydrostatic) ± 0,3°C for temperatureCable: 5 or 10 m from sensor to backpackPower Supply: rechargeable battery pack LiFePO4 6.000 mAhOperation Time: +24 hours (sensor & transmitter) tablet depending on model Dimensions: 210x160x61 mm (LxWxH)

Accessories: backpack to fit all components

The AquaProfiler® M-Pro is an instrument that oper-ates in a manner very similar to an Acoustic Doppler Current Profiler (ADCP). The primary difference is that the probe is kept fixed on the channel bottom and provides vertical velocity data in up to 128 cells. Due to the very small cell size (0,005 m), a resolution of the vertical velocity distribution can be achieved which was unthinkable a few years ago. The AquaProfiler® M-Pro is a device that extends the capability of flow measurements to a range of situations under which standard current meter techniques (mechanical or electromagnetic) cannot be used.

The AquaProfiler® M is a high-precision point-

velocity meter. It uses a complex pulse-to-pulse co-

herent sampling scheme that gives the instrument

high precision in measurement of velocity within a

very small volume a few centimeters in front of the

sensor. The small sampling volume provides velocity

data that can be considered as point velocities.

The advantages over mechanical meters include:

no moving parts, thus less maintenance required,

minimal flow disturbance, velocity measurements

as low as 0,005 m/s and minimum operating depth

of 2 cm.

24

Page 25: Hydro vision brochure_acousticflowmeasurement_en
Page 26: Hydro vision brochure_acousticflowmeasurement_en

Service

Look at him! The short target deadline was met once again. Our hard work of the past two weeks has finally paid off. The acoustic flow measuring system for a hydropower plant has passed its final test. Everything works fine - this is the best moment a project engineer can have.

Thanks to the excellent professional competence of our service department we manage projects all over the world. Skilled service technicians, electronic technicians, project engineers and training staff provide advice and support from project planning all the way to the turnkey installation.

Our products are mostly customized. Prior to the project planning we inspect the measuring site in order to submit a detailed solution.

For instant clarifications you can contact our telephone support. Or browse our website on your own to find the suitable product for your application.

We know flow.®

26

Page 27: Hydro vision brochure_acousticflowmeasurement_en

HydroVision worldwide

CanadaWaste Water Treatment Plant

System: Kanalis TTTransducer: TD-200/8

IcelandHydro Power

System: Ductus TT COHPTransducer: Clamp-On

TurkeyHydro Power

System: Ductus TT (19``)Transducer: External mount

South KoreaRiver

System: Fluvius TTTransducer: TD-15/17

USAWaste Water Treatment Plant

System: Q-Eye PSCTransducer: Pulse Doppler

Great BritainWater Supply

System: Ductus TTTransducer: Internal mount

EgyptIrrigation channel

System: Kanalis TTTransducer: TD-200/8

JapanRiver

System: Fluvius TTTransducer: TD-28/18

27

Page 28: Hydro vision brochure_acousticflowmeasurement_en

HydroVision GmbH

Gewerbestraße 61A

87600 Kaufbeuren

Germany

tel. +49 - 8341 - 9662180

fax +49 - 8341 - 9666030

[email protected]

www.hydrovision.de

© 03/2015 HydroVision GmbH. Specifications are for instruments at the time the literature was printed. Due to continuous product testing and improvement, all specifications are subject to change without notice.

represented by:HydroVision Asia Pte. Ltd.

1 Cleantech Loop

#03-05 CleanTech One

Singapore 637141

tel. +65 67776330

fax.+65 67773537

[email protected]

www.hydrovision.sg