15
Demonstration Thermography report Company Device Customer E-Mail: [email protected] Phone: 01420 544433 Andy McGrath - Testo Tester: 32 degree, Wide Angle Lens Lens: 1434423, 01729604 & 01710401 Serial No.: Testo 880-3, 875-2 & 881-3 Demo Report Testo Thermal Imaging Cameras Testo Ltd Various Measuring Date: Various Applications for Testo Thermal Imaging cameras in HVAC. Demonstration Thermography Report Measuring Site: Demonstration Thermography Report to highlight the capabilities of the Testo Thermal Imaging cameras for various applications associated to HVAC. Task Alton, GU34 2QJ Newman Lane Testo Ltd 1/15 Page

Demo report 25 std hvac applications

Embed Size (px)

Citation preview

Page 1: Demo report 25 std hvac applications

Demonstration Thermography report

Company

Device

Customer

E-Mail: [email protected]

Phone: 01420 544433

Andy McGrath - Testo

Tester:

32 degree, Wide AngleLens

Lens:

1434423, 01729604 &01710401

Serial No.:Testo 880-3, 875-2 & 881-3

Demo Report

Testo Thermal ImagingCameras

Testo Ltd

VariousMeasuring Date:

Various Applications for Testo ThermalImaging cameras in HVAC.

Demonstration Thermography Report

Measuring Site:

Demonstration Thermography Report to highlight the capabilities of theTesto Thermal Imaging cameras for various applications associated toHVAC.

Task

Alton, GU34 2QJ

Newman Lane

Testo Ltd

1/15Page

Page 2: Demo report 25 std hvac applications

Demonstration Thermography report

File:

IV_00518.BMT 14/01/2009

Measuring Time:

12:57:02

20.0Refl. temp. [°C]:

0.95Emissivity:

Picture parameters:

Date:

Picture markings:

RemarksRefl. temp. [°C]Emiss.Temp. [°C]Measurement Objects

Spot Temp 1 to indicatetemperature variation across thefloor

20.00.9520.7Measure point 1

Spot Temp 2 to indicatetemperature variation across thefloor

20.00.9530.0Measure point 2

Spot Temp 3 to indicatetemperature variation across thefloor

20.00.9530.9Measure point 3

Spot Temp 4 to indicatetemperature variation across thefloor

20.00.9523.3Measure point 4

Profile line:

Thermal Survey, specifically in a Utility Room for Trace and Access application.Thermal and Digital imagesof Floor area taken as part of an investigation for possible leaks. Thermal image highlights temperaturevariation across the floor, this is therefore an indication of the location of the heating pipework under thefloor.

Remarks:

2/15Page

Page 3: Demo report 25 std hvac applications

Demonstration Thermography report

File:

IV_00662.BMT 09/04/2009

Measuring Time:

08:27:40

20.0Refl. temp. [°C]:

0.95Emissivity:

Picture parameters:

Date:

Picture markings:

RemarksRefl. temp. [°C]Emiss.Temp. [°C]Measurement Objects

-20.00.9519.7Measure point 1

-20.00.9522.5Measure point 2

-20.00.9519.2Measure point 3

Profile line:

Thermal Survey at a Domestic Property.Thermal and Digital images of Floor area taken as part of aninvestigation for possible leaks. Thermal image highlights temperature variation across the floor, this istherefore an indication of the location of the heating pipework under the floor.Spot temperature markershighlight temperature difference across floor where heating pipework is located.

Remarks:

3/15Page

Page 4: Demo report 25 std hvac applications

Demonstration Thermography report

File:

IV_00663.BMT 09/04/2009

Measuring Time:

08:28:15

20.0Refl. temp. [°C]:

0.95Emissivity:

Picture parameters:

Date:

Picture markings:

RemarksRefl. temp. [°C]Emiss.Temp. [°C]Measurement Objects

-20.00.9520.9Measure point 1

-20.00.9523.5Measure point 2

-20.00.9520.6Measure point 3

Profile line:

Thermal Survey at a Domestic Property.Thermal and Digital images of Floor area taken as part of aninvestigation for possible leaks. Thermal image highlights temperature variation across the floor, this istherefore an indication of the location of the heating pipework under the floor.Spot temperature markershighlight temperature difference across floor where heating pipework is located.

Remarks:

4/15Page

Page 5: Demo report 25 std hvac applications

Demonstration Thermography report

File:

IV_00383.BMT 08/12/2008

Measuring Time:

13:26:37

20.0Refl. temp. [°C]:

0.95Emissivity:

Picture parameters:

Date:

Picture markings:

RemarksRefl. temp. [°C]Emiss.Temp. [°C]Measurement Objects

Spot Temp 1 on Tiled Flooradjacent to radiator

20.00.9517.6Measure point 1

Spot Temp 2 on Tiled Flooradjacent to end of Skirting board

20.00.9516.9Measure point 2

Spot Temp 3 on Tiled Floor nextto glazed section

20.00.9516.6Measure point 3

Spot Temp 4 on Tiled floor areaaway from where the hot waterpipes are located

20.00.9514.3Measure point 4

Spot Temp 5 on Tiled floor areaaway from where the hot waterpipes are located

20.00.9514.2Measure point 5

Profile line:

Demonstration Thermal survey conducted with Testo 880 series Thermal Imaging camera. Conducted inGlazed walkway between Lounge and Kitchen extension.The homeowner is complaining of possible water leak under the tiled floor. At the time that this Thermal andDigital image were taken, the heat pattern effect from the hot water pipes under the floor were able to beseen in the the Thermal image, travelling the length of the walkway but no anomaly is apparent at this stage.Spot Temperatures have been added to the image to indicate the temperatures along the path of the pipes.A temperature profile line graph has been added to the thermal image, to highlight the temperature variationacross the tiled floor.

Remarks:

5/15Page

Page 6: Demo report 25 std hvac applications

Demonstration Thermography report

File:

IV_00386.BMT 08/12/2008

Measuring Time:

13:32:32

20.0Refl. temp. [°C]:

0.95Emissivity:

Picture parameters:

Date:

Picture markings:

RemarksRefl. temp. [°C]Emiss.Temp. [°C]Measurement Objects

Spot Temp 1 to indicatetemperature variation across thefloor

20.00.9518.1Measure point 1

Spot Temp 2 to indicatetemperature variation across thefloor

20.00.9518.4Measure point 2

Spot Temp 3 to indicatetemperature variation across thefloor

20.00.9515.7Measure point 3

Spot Temp 4 to indicatetemperature variation across thefloor

20.00.9514.9Measure point 4

HS1 Hottest point on ThermalImage

20.00.9521.0Hot spot 1

Profile line:

Thermal survey conducted with Testo 880 series Thermal Imaging camera for Trace and Access application.In Glazed walkway between Lounge and Kitchen extension. The homeowner is complaining of possiblewater leak under the tiled floor. The Thermal image shows the heat pattern effect from the heating pipesunder the floor, travelling the length of the walkway and now a hot spot can be seen clearly. This is anindication of an anomaly, a possible leak from the central Heating system. The temperature in this area hasincreased and is indicating an anomaly that requires investigation.

Remarks:

6/15Page

Page 7: Demo report 25 std hvac applications

Demonstration Thermography report

File:

IV_00585.BMT 10/03/2009

Measuring Time:

16:15:17

20.0Refl. temp. [°C]:

0.95Emissivity:

Picture parameters:

Date:

Picture markings:

RemarksRefl. temp. [°C]Emiss.Temp. [°C]Measurement Objects

Spot Temp 1 for temperaturecomparison.

20.00.9522.8Measure point 1

Spot Temp 2 for temperaturecomparison.

20.00.9515.5Measure point 2

Spot Temp 3 for temperaturecomparison.

20.00.9515.0Measure point 3

Spot Temp 4 for temperaturecomparison.

20.00.9523.4Measure point 4

Spot Temp 5 for temperaturecomparison.

20.00.9526.2Measure point 5

Profile line:

Thermal and Digital images of a domestic radiator.Taken with Testo 880 series Thermal imaging camera to demonstrate the capabilities of the camera and theTesto IR software.Spot temperature markers have been added to show the temperature variation across the radiator. Atemperature profile line graph has also been added to visually show the temperature profile across the raditorvertically.

Remarks:

7/15Page

Page 8: Demo report 25 std hvac applications

Demonstration Thermography report

File:

IV_00596.BMT 10/03/2009

Measuring Time:

16:21:02

20.0Refl. temp. [°C]:

0.95Emissivity:

Picture parameters:

Date:

Picture markings:

RemarksRefl. temp. [°C]Emiss.Temp. [°C]Measurement Objects

Spot Temp 1 for temperaturecomparison.

20.00.9529.7Measure point 1

Spot Temp 2 for temperaturecomparison.

20.00.9526.0Measure point 2

Spot Temp 3 for temperaturecomparison.

20.00.9520.5Measure point 3

Profile line:

Thermal and Digital images of a domestic radiator.Taken with Testo 880 series Thermal imaging camera to demonstrate the capabilities of the camera and theTesto IR software.Spot temperature markers have been added to show the temperature variation across the radiator. Atemperature profile line graph has also been added to visually show the temperature profile across the raditordiagonally. The palette has been changed to Hot/Cold.

Remarks:

8/15Page

Page 9: Demo report 25 std hvac applications

Demonstration Thermography report

File:

IV_00601.BMT 10/03/2009

Measuring Time:

16:24:10

20.0Refl. temp. [°C]:

0.95Emissivity:

Picture parameters:

Date:

Picture markings:

RemarksRefl. temp. [°C]Emiss.Temp. [°C]Measurement Objects

-20.00.9531.2Measure point 1

-20.00.9527.6Measure point 2

-20.00.9522.0Measure point 3

-20.00.9539.0Measure point 4

Histogram:

Profile line:

Thermal and Digital images of a domestic radiator.Taken with Testo 880 series Thermal imaging camera to demonstrate the capabilities of the camera and theTesto IR software.Additional spot temperature markers have been added to show the temperature variation across the radiator.A temperature profile line graph has also been added to visually show the temperature profile across theraditor diagonally. A Histogram has also been applied to the thermal image which defines the number oftemperature points at specific temperatures within a defined area.

Remarks:

9/15Page

Page 10: Demo report 25 std hvac applications

Demonstration Thermography report

File:

IV_00537.BMT 29/01/2009

Measuring Time:

10:58:15

20.0Refl. temp. [°C]:

0.95Emissivity:

Picture parameters:

Date:

Picture markings:

RemarksRefl. temp. [°C]Emiss.Temp. [°C]Measurement Objects

Spot Temp 1 indicates Floortemperature above the coil

20.00.9529.5Measure point 1

Spot Temp 2 indicates Floortemperature above the coil

20.00.9529.4Measure point 2

Spot Temp 3, indicates the floortemperature at section wherethere is no heating coil

20.00.9522.7Measure point 3

Spot Temp 4 indicates Floortemperature above the coil

20.00.9528.9Measure point 4

Spot Temp 5 indicates Floortemperature above the coil

20.00.9529.1Measure point 5

Spot Temp 6, indicates the floortemperature at section wherethere is no heating coil

20.00.9524.8Measure point 6

Spot Temp 7 indicates Floortemperature above the coil

20.00.9530.0Measure point 7

Spot Temp 8 indicates Floortemperature above the coil

20.00.9529.1Measure point 8

Spot Temp 9, indicates the floortemperature at section wherethere is no heating coil

20.00.9524.5Measure point 9

Auto Hot spot indicator20.00.9533.9Hot spot 1

10/15Page

Page 11: Demo report 25 std hvac applications

Demonstration Thermography report

Profile line:

Thermal and Digital Images of Office Floor, taken with the Testo 880 series Thermal Imaging camera.The Thermal image highlights the location of the underfloor heating coils.A temperature Profile Line graph has been applied to the Thermal image to verify the temperatures acrossthe underfloor heating coils.Spot temperature markers have been added to indicate the temperatures of the system at the floor surface.The thermal image is shown in "Iron" palette.

Remarks:

11/15Page

Page 12: Demo report 25 std hvac applications

Demonstration Thermography report

File:

IV_00538.BMT 29/01/2009

Measuring Time:

10:58:30

20.0Refl. temp. [°C]:

0.95Emissivity:

Picture parameters:

Date:

Picture markings:

RemarksRefl. temp. [°C]Emiss.Temp. [°C]Measurement Objects

-20.00.9534.8Measure point 1

-20.00.9531.7Measure point 2

-20.00.9535.0Measure point 3

-20.00.9539.1Hot spot 1

Profile line:

Thermal and Digital Images of Office Floor, taken with the Testo 880 series Thermal Imaging camera.The Thermal image highlights the underfloor heating coils.The thermal image also has the auto Hot spot indicator applied to indicate automatically, the hottest point"HS1" in the designated area.A temperature Profile Line graph has been applied to the Thermal image to verify the temperatures acrossthe underfloor heating coils.Spot temperature markers have been added to indicate the temperatures of the system at the floor surface.The Thermal image is shown in "Iron" Palette.

Remarks:

12/15Page

Page 13: Demo report 25 std hvac applications

Demonstration Thermography report

File:

IV_01244.BMT 04/09/2009

Measuring Time:

17:37:00

20.0Refl. temp. [°C]:

0.96Emissivity:

Picture parameters:

Date:

Picture markings:

RemarksRefl. temp. [°C]Emiss.Temp. [°C]Measurement Objects

-20.00.9624.9Measure point 1

-20.00.9644.4Measure point 2

-20.00.9651.0Measure point 3

-20.00.9643.4Measure point 4

Demonstration Thermal Survey, at a Domestic Property.Thermal and Digital images of Hot Water system,Dual Pump for shower. Thermal image highlights temperature variation across the equipment and pipework,Spot temperature markers highlight temperature difference in respect of the pipework and pump and indicatewhich sections are operational.

Remarks:

13/15Page

Page 14: Demo report 25 std hvac applications

Demonstration Thermography Report to highlight the capabilities of the Testo Thermal Imaging cameraS and the Testo IR software.

This is an example report for Demonstration purposes only. The format is the "Standard" report template from the selection of Report Templates available in the software.

There are various subjects for the Thermal images and this report is compiled to indicate the capability of the cameras and the software for a number of applications in the HVAC Industry.

Some of the features of the camera and software have been applied to the Thermal images.

Spot Temperature markers have been added to the thermal images to indicate temperatures.

Auto Hot / Cold Spot Indicator has been applied, which automatically highlights the Hottest or Coldest point

Demonstration Thermography report

File:

IV_01224.BMT 04/09/2009

Measuring Time:

16:45:34

20.0Refl. temp. [°C]:

0.96Emissivity:

Picture parameters:

Date:

Picture markings:

RemarksRefl. temp. [°C]Emiss.Temp. [°C]Measurement Objects

-20.00.9644.7Measure point 1

-20.00.9647.8Hot spot 1

Profile line:

Demonstration Thermal Survey, at a Domestic Property.Thermal and Digital images of Hot Water Pump.Thermal image highlights temperature variation across the equipment and pipework, Spot temperaturemarkers highlight temperature difference in respect of the pipework and pump and indicate which sectionsare operational.

Remarks:

Review:

14/15Page

Page 15: Demo report 25 std hvac applications

Demonstration Thermography report

Auto Hot / Cold Spot Indicator has been applied, which automatically highlights the Hottest or Coldest point in the defined area.

Temperature Profile Line Graph shows the temperature variation in graph form across the subject.

Palettes Various palettes (from the range available) have been used.

The images are automatically Time and Date Stamped to verify the time and date when the images were taken.

The report also details the Emissivity value relating to the image taken.

Andy McGrath - Testo

,25/09/2009

15/15Page