LIST OF EN1317 COMPLIANT ROAD RESTRAINT SYSTEMS
January 2015 (last issue dated July 2014)
CONTENTS:
Safety Barriers (SB) Part 1: List of permanent safety barrier systems that the HA has been advised
have been CE marked in accordance with the Construction Products Regulation (CPR).
Part 2: List of permanent safety barrier systems that are not CE marked in
accordance with the CPR and are accepted for use on HA roads.
Temporary Safety Barriers (TSB)
Parapets (P)
Crash Cushions (CC)
Terminals (T)
Transitions (TRANS)
Safety Barrier Gates (SBG)
Miscellaneous (M)
Truck Mounted Attenuators (TMAs)
The List of EN1317 Compliant Road Restraint Systems is periodically updated. To view or
download the current version of this list contact: http://www.dft.gov.uk/ha/standards/tech_info/
Sector Scheme Training Requirements, New Products, Relisted Products & Amendments January 2015
Sector Scheme Training Requirements Note from TD19/06: 1.17 All VRS installed for use on the Trunk Road network, and on all roads in Northern Ireland, must be installed and maintained by qualified personnel in accordance with Sector Schemes 2B and 5B (see Appendix A of MCHW-1), where these schemes are applicable. VRS, such as bridge and pedestrian parapets or cast in-situ concrete barriers, that are not covered by these Sector Schemes must be installed and maintained by suitably trained and experienced personnel. New Products – January 2015
•••• Safety Barriers (Permanent)
- Hill and Smith; Hi Flex Safety Fence - Asebal USA; AS-BLB.C - Asset International; VarioGuard TVRS (with non-invasive anchorages) - Ferrostrada (UK); N2W2-MARC2006 - Ferrostrada (UK); H1BL-MARC2008 - SafeRoad UK; MegaRail eb - SafeRoad UK; MegaRail ec 3.3 - SafeRoad UK; MegaRail sk - SafeRoad UK; Vik CC2-W3 - SafeRoad UK; Vik CC4-W3 - Rebloc; RB80_8_N2/W3 - Rebloc; RB80_8_H1/W4 - Rebloc; RB80_8_H2/W5 - Rebloc; RB80A_8_H2/W1 - Rebloc; RB100_2_H2/W5 - Rebloc; NB100/300_8_H2/W4
•••• Safety Barriers (Temporary)
- Rebloc; RB80_8_H1/W4 - Rebloc; RB80A_8_H2/W1 - Rebloc; RB100_2_H2/W5 - System Spengler Transportable Double Sided Precast Concrete Barrier
(height 0.81m) at N2 containment level
•••• Crash Cushions - Highway Care; TAU Medium Crash Cushion Family - Highway Care; TAU Large Crash Cushion Family - Highway Care; TAU Tube P110 Crash Cushion - Industry AMS Srl; SMA Crash Cushion Family
•••• Terminals
- SafeRoad UK; SafeEnd P1 terminal - SafeRoad UK; SafeEnd P4 Terminal
•••• Safety Barrier Gates - SafeRoad UK; Steel Step Barrier Gate
Sector Scheme Training Requirements, New Products, Relisted Products & Amendments January 2015
Note: For further details on these systems, please see relevant section within the EN1317 Compliant Road Restraint Systems List. Amendments/Other Changes
•••• Listing of in-situ concrete products under ‘Safety Barriers (Part 1)’ •••• Change of promoter for the SafeEnd system from Birsta to SafeRoad UK Ltd. •••• Change of name for Highway Care ‘Solo-bois’ product range to ‘Nature Rail’ •••• Movement of the Highway Care Armorzone Longitudinal Barrier (ALB) from
permanent to temporary safety barriers •••• Change of contact details for Brifen and Hill and Smith •••• Change of contact details for Ferrostrada (UK) Ltd
Return to Contents
SAFETY BARRIERS (PART 1)
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
H2 W2 0.1 No NR B Ardee Precast Concrete Limited EN1317-5:2007+A1:2008Town ParksArdeeCo. LouthIrelandTel. +353 41 6856372Fax. +353 41 6857216email: info@ardeeprecastconcrete.com Web Site: www.ardeeprecastconcrete.com
N2 W2 0.6 No NA A Asebal EN1317-5:2007Glorieta del Agua. Edif.Aljamar
Center Portal 2Planta 1Local 1141940 Tomares (Sevilla)SpainTel: +34 944 270 084Fax: +34 944 271 507email: bjorn.vanwamelen@asebal.com
N2 W3 1.0 No NA A Asebal EN1317-5:2007Glorieta del Agua. Edif.AljamarCenter Portal 2Planta 1Local 1141940 Tomares (Sevilla)SpainTel: +34 944 270 084Fax: +34 944 271 507email: bjorn.vanwamelen@asebal.com
H1 W5 0.7 No NR B Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter.wilkinson@hill-smith.co.ukWeb Site: www.asset-vrs.co.ukAsset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale AvenueBilstonWolverhampton
N2 W6 No NA B WV14 0QLTel. 01902 499402
H2 W8 No NR B Fax. 01902 402104email: peter.wilkinson@hill-smith.co.uk
H1 W8 No NR B Web Site: www.asset-vrs.co.ukAsset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale AvenueBilstonWolverhampton
N2 W6 No NA B WV14 0QLTel. 01902 499402
H2 W8 No NR B Fax. 01902 402104email: peter.wilkinson@hill-smith.co.uk
L2 W8 No NR B Web Site: www.asset-vrs.co.ukAsset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale AvenueBilstonWolverhampton
N2 W4 No NA B WV14 0QLTel. 01902 499402Fax. 01902 402104email: peter.wilkinson@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
Double Sided BSWF, Type NJ 93BK
AS-MEB.A
The following Safety Barriers have been successfully tested to meet the requirements of BS EN 1317 -1 and -2 and the HA has been advised that they have been CE marked in accordance with the Construction Products Directive (CPD) or Regulation (CPR) for the Containment Performance Class and Working Width Class stated below.
Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.The Safety Barriers shall comply with the manufacturer's Specification, component descriptions and Installation procedures.
Further information on Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.
NA: Not ApplicableNR: Not Reported
AS-BLB.C
SOLOGUARD Emergency and Maintenance Crossing Point System
Varioguard Double Sided Safety Barrier - SYSTEM No. 1
For a tested length of 60m between end anchors, and anchored in accordance with the EN1317
compliant test, the working width class
Varioguard Double Sided Steel Safety Barrier - SYSTEM No. 3
For a tested length of 88m between end anchors, and anchored in accordance with the EN1317
Note: For a different installation length please contact the
Promoter for information
concerning the Working Width of
the system.
Note: For a different installation length please contact the
Promoter for information
concerning the Working Width of
the system.
Varioguard 'Quick Joint' Steel Safety Barrier - SYSTEM No. 2
For a tested length of 68m between end anchors, and anchored in accordance with the EN1317
compliant test, the working width class
Note: For a different installation length please contact the
Promoter for information
concerning the Working Width of
the system.
Safety Barriers (Part 1) 1 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale AvenueBilstonWolverhampton
N2 W3 No NA B WV14 0QLTel. 01902 499402Fax. 01902 402104email: peter.wilkinson@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
H1 W6 1.4 No NR B Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter.wilkinson@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
H1 W6 1.4 No NR B Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter.wilkinson@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
N2 NR No NA A Brifen (A Division of Hill and Smith) EN1317-5:2007Springvale Business and Industrial ParkBilstonWolverhampton
N2 NR No NA A West Midlands EN1317-5:2007WV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
N2 NR No NA A Brifen (A Division of Hill and Smith) EN1317-5:2007Springvale Business and Industrial Park
BilstonWolverhampton
N2 NR No NA A West Midlands EN1317-5:2007WV14 0QLTel: 01902 499400Fax: 01902 499419
N2 NR No NA A Email: technical@hill-smith.co.uk EN1317-5:2007Web: www.hill-smith.co.uk
H1 NR No NA A EN1317-5:2007
N2 W1/W2 0.0 No NA B Britpave Barrier Systems Ltd EN1317-5:2007Atrium Court
H2 W1/W2 NR Yes NR B The RingBracknellBerkshireRG12 1BWTel. 01344 393300email: info@bbsbarriers.comWeb site: www.bbsbarriers.com
H2 W3 0.0 No NR B Britpave Barrier Systems Ltd EN1317-5:2007Atrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: info@bbsbarriers.comWeb site: www.bbsbarriers.com
H2 W1/W2 NR Yes NR B Britpave Barrier Systems Ltd EN1317-5:2007Atrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: info@bbsbarriers.comWeb site: www.bbsbarriers.com
Varioguard Double Sided Safety Barrier - TVRS with non invasive anchorages
Brifen 3 Rope Safety Barrier
With post centres at 1.2m the Working Width Class is: W4
With post centres at 3.2m then the Working Width Class is: W6
With post centres at 3.2m then the Working Width Class is: W5
With post centres at 3.2m the Working Width Class is: W7
With post centres at 3.2m the Working Width Class is: W5
With post centres at 3.2m the Working Width Class is: W4
Brifen 4 Rope Safety Barrier
Varioguard Single Sided Steel Safety Barrier - SYSTEM No. 4
For a tested length of 88m between end anchors, and anchored in accordance with the EN1317
Note: For a different installation length please contact the
Promoter for information
concerning the Working Width of
the system.
Varioguard Single Sided Safety Barrier - SYSTEM No. 7
Concrete Step Barrier (CSB), Issue 5 Drawing file release
Wide Concrete Step Barrier (WCSB), Issue 5 Drawing file release
Variable Concrete Step Barrier (VCSB), Issue 5 Drawing file release
Safety Barriers (Part 1) 2 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
H2 W3 0.0 No NR B Britpave Barrier Systems Ltd EN1317-5:2007H1 Atrium Court
The RingBracknellBerkshireRG12 1BWTel. 01344 393300email: info@bbsbarriers.comWeb site: www.bbsbarriers.com
H2 W2 NR No NR B Britpave Barrier Systems Ltd EN1317-5:2007Atrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: info@bbsbarriers.comWeb site: www.bbsbarriers.com
H2 W3 NR No NR B Britpave Barrier Systems Ltd EN1317-5:2007Atrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: info@bbsbarriers.comWeb site: www.bbsbarriers.com
H2 W2 NR No NR B Britpave Barrier Systems Ltd EN1317-5:2007Atrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: info@bbsbarriers.comWeb site: www.bbsbarriers.com
H2 W3 NR No NR B Britpave Barrier Systems Ltd EN1317-5:2007Atrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: info@bbsbarriers.comWeb site: www.bbsbarriers.com
N1 W5 0.9 Yes NA A Colas Ltd EN1317-5:2007+A2:2012NewcastleDerwenthaugh Industrial EstateDerwenthaugh RoadSwalwellNE16 3BQTel: 0191 414 6511email: vrs@colas.co.ukWeb site: www.colas.co.uk
N2 W6 1.6 Yes NA A Colas Ltd EN1317-5:2007+A2:2012NewcastleDerwenthaugh Industrial EstateDerwenthaugh RoadSwalwellNE16 3BQTel: 0191 414 6511email: vrs@colas.co.ukWeb site: www.colas.co.uk
N1 W4 0.6 Yes NA A Colas Ltd EN1317-5:2007+A2:2012NewcastleDerwenthaugh Industrial EstateDerwenthaugh RoadSwalwellNE16 3BQTel: 0191 414 6511email: vrs@colas.co.ukWeb site: www.colas.co.uk
N2 W5 0.9 Yes NA B Colas Ltd EN1317-5:2007+A2:2012NewcastleDerwenthaugh Industrial EstateDerwenthaugh RoadSwalwellNE16 3BQTel: 0191 414 6511email: vrs@colas.co.ukWeb site: www.colas.co.uk
Steel Step Barrier (SSB)
SMS+ (anchored every 12m)
SMS+ (unanchored)
Wide Variable Steel Step Barrier (WVSSB)
SMS+ (unanchored)
SMS+ (anchored every 12m) Note: Only permitted for use on
roads where road works are being
undertaken and a speed limit of less
than 50 mph is operative.
Wide Steel Step Barrier (WSSB)
Variable Steel Step Barrier (VSSB)
Wide Variable Concrete Step Barrier (WVCSB), Issue 5 Drawing file release
Safety Barriers (Part 1) 3 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
N2 W5 1.0 Yes NA B Colas Ltd EN1317-5:2007+A2:2012NewcastleDerwenthaugh Industrial EstateDerwenthaugh RoadSwalwellNE16 3BQTel: 0191 414 6511email: vrs@colas.co.ukWeb site: www.colas.co.uk
H2 W2 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W2 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W2 - W4 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W2 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W2 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W2 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W2 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W2 0.0 Yes VI1 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
SMS+ (anchored every 24m)
Delta Bloc EP80B-E In-situ concrete barrier
Delta Bloc EP80B-E Variable height
Delta Bloc EP80B-E Wide
Delta Bloc EP80Ba In-situ concrete barrier surface mounted on asphalt
Delta Bloc EP80Ba-LB In-situ concrete barrier surface mounted on asphalt - Low Base
Delta Bloc EP80Ba-EB In-situ concrete barrier surface mounted on asphalt - Elevated Base
Delta Bloc EP80Ba-VW In-situ concrete barrier surface mounted on asphalt - Variable Width
Delta Bloc EP80Ba-VH In-situ concrete barrier surface mounted on asphalt - Variable Height
Safety Barriers (Part 1) 4 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
H2 W3 0.2 Yes VI2 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N2 W3 0.4 NR NA B DELTA BLOC UK Ltd EN1317-5:2007+A1:2008Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H1 W6 NR Yes NR B DELTA BLOC UK LtdUnit A Fox Way
N2 W4 NR NR NA B Trinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N2 W4 0.6 NR NA B DELTA BLOC UK Ltd EN1317-5:2007+A1:2008Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N1 W4 NR NR NA A DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H1 W6 NR NR NR B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H1 W4 0.6 NR NR B DELTA BLOC UK Ltd EN1317-5:2007+A1:2008Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H1 W6 NR NR NR B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W1 0.1 NR NR B DELTA BLOC UK Ltd EN1317-5:2007+A1:2008Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
Delta Bloc DB65S/6m (K120S)
Delta Bloc DB80/4m (K120S)
Delta Bloc DB80/6m (K150S)
Delta Bloc DB80/4m (K150S)
Delta Bloc DB80/4m (K180)
Delta Bloc DB80/4m (K180)
Note: Only permitted for use on
roads where road works are being
undertaken and a speed limit of less
than 50 mph is operative.
Delta Bloc DB80/6m (K150S)
Delta Bloc DB80-E/6m (K150S)
Delta Bloc EP80Bs In-situ concrete barrier surface mounted on subbase/ compacted gravel
Safety Barriers (Part 1) 5 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
H2 W1 0.0 NR NR B DELTA BLOC UK Ltd EN1317-5:2007+A1:2008Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W3 NR NR NR B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W4 0.7 NR NR B DELTA BLOC UK Ltd EN1317-5:2007+A1:2008Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W4 NR NR NR B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W5 NR NR NR B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W5 NR NR NR A DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W6 NR NR NR B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W6 NR NR NR C DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H4a W6 1.4 Yes VI9 B DELTA BLOC UK Ltd EN1317-5:2007+A2:2012Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
Delta Bloc DB80-F/6m (K180)
Delta Bloc DB80AS-A/6m (K120S)
Delta Bloc DB100S/6m (K220)
Delta Bloc DB80/6m (K180S)
Delta Bloc DB90 Step/6m (K220)
Delta Bloc DB100/6m (K280)
Delta Bloc DB80AS-F/6m (K120S)
Delta Bloc DB80AS-R/6m (K180)
The installation of safety barriers with an ASI Class of C must be with the agreement of the
Overseeing Organisation (refer
to TD19/06, Sections 3.6 and 3.7).
Delta Bloc DB80AS-E/6m (K180S)
Safety Barriers (Part 1) 6 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
H1 W6 1.4 Yes NR B Manufactured by: SGGT Strassenausstattungen GmbH EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
N2 W4 0.7 Yes NA B Manufactured by: SGGT Strassenausstattungen GmbH EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) Limited
H1/L1 W5 1.0 Yes NR B Venlaw House EN1317-5:2007+A1:2008Burston Road
H2/L2 W7 1.8 Yes NR B Heywood EN1317-5:2007+A1:2008South NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
N2 W3 0.8 Yes NA A Manufactured by: Duero EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
N2 W4 1.0 Yes NA A Manufactured by: Duero EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
N2 W5 1.2 Yes NA A Manufactured by: Duero EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
H1 W4 1.2 No NR A Manufactured by: Duero EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
Duo Rail-KA
Duo Rail-KAB
DSS-N2W3 safety fence
DSS-N2W4 safety fence
DSS-N2W5 safety fence
DSS-H1W4 safety fence
Safety Barriers (Part 1) 7 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
H3 W2 0.5 No NR B Manufactured by: Duero EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
N2 W2 0.7 No NA A Manufacturer: Marcegaglia Buildtech S.r.l EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth Norfolk
IP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
H1BL-MARC2008 H1 W3 0.7 No NR A Manufacturer: Marcegaglia Buildtech S.r.l EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
H2 W6 1.9 No NR A Manufacturer: Marcegaglia Buildtech S.r.l EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
H2 W4 1.1 No NR A Manufacturer: Marcegaglia Buildtech S.r.l EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
H2 W3 0.9 Yes NR A Manufacturer: Marcegaglia Buildtech S.r.l EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
DSS-H3W2 safety fence
H2BL-MARC2006
H2BL-MARC2007
H2BLW-MARC2011
N2W2-MARC2006
Safety Barriers (Part 1) 8 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
H2 W5 1.1 Yes NR B Manufacturer: Marcegaglia Buildtech S.r.l EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
H2 W4 1.3 Yes NR A Manufacturer: Marcegaglia Buildtech S.r.l EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
N2 W1 0.5 No NA B Manufactured by: SGGT Strassenausstattungen GmbH EN1317-5:2007+A1:2008Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
H2 W3 0.8 No NR B Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
H2 W2 0.5 No NR B Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
H2 W2 0.5 No NR B Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
H2 W4 0.5 No NR B Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
ESP Plus W1
ZB4-1
ZB4-2
ZB4-3
ZB4-4
PAB H2 BPC
PAB H2 CE
Safety Barriers (Part 1) 9 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
N2 W4 1.3 No NA A Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
N2 W4 1.3 No NA A Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
N2 W5 1.6 No NA A Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth Norfolk
IP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
N2 W5 1.7 No NA A Ferrostrada (UK) Limited EN1317-5:2007+A1:2008Venlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
N2 W4 NR No NA B Highway Care Ltd. EN1317-5:2007+A1:2008The Highlands
H2 W6 NR No NR B Detling Hill EN1317-5:2007+A1:2008Detling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
N2 W2 0.7 No NA A Highway Care Ltd. EN1317-5:2007+A1:2008The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
H1 W4 1.2 No NR A Highway Care Ltd. EN1317-5:2007+A1:2008The Highlands
L1 W4 1.2 No NR A Detling Hill EN1317-5:2007+A1:2008Detling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
ZS1-44
ZS1-83
ZS1-84
Quickchange Moveable Barrier (QMB) Permanent Application
Heintzmann Basic Barrier 1.33 Profil A
Heintzmann Basic Barrier 1.33 Profil A
ZS1-43
Safety Barriers (Part 1) 10 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
H1 W3 0.9 No NR A Highway Care Ltd. EN1317-5:2007+A1:2008The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
N2 W4 1.2 No NA A Highway Care Ltd. EN1317-5:2007+A1:2008The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
N2 W3 0.9 No NA A Highway Care Ltd. EN1317-5:2007+A1:2008The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
N2 W5 1.4 No NA A Highway Care Ltd. EN1317-5:2007+A1:2008The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
N2 W5 1.4 No NA A Highway Care Ltd. EN1317-5:2007+A1:2008The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
N2 W7 2.2 No NA A Highway Care Ltd. EN1317-5:2007+A1:2008The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
H2 NR No NR A Hill and Smith EN1317-5:2007Springvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
With post centres at 1.6m the Working Width Class is: W5
Heintzmann Basic Barrier 1.33 Profil A
Nature Rail S4.2
Nature Rail S4.4
Heintzmann Basic Barrier 2.0 Profil A
Heintzmann Basic Barrier 2.0b Profil A
Heintzmann Basic Barrier 4.0 Profil A
Bri-Flex Double Sided Corrugated Beam and Wire Rope VRS
Safety Barriers (Part 1) 11 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
N2 NR No NA A Hill and Smith EN1317-5:2007Springvale Business and Industrial ParkBilstonWolverhampton
N2 NR No NA A West Midlands EN1317-5:2007WV14 0QLTel: 01902 499400Fax: 01902 499419
N2 NR No NA A Email: technical@hill-smith.co.uk EN1317-5:2007Web: www.hill-smith.co.uk
N2 NR No NA A Hill and Smith EN1317-5:2007Springvale Business and Industrial ParkBilstonWolverhampton
N2 NR No NA A West Midlands EN1317-5:2007WV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
N2 NR No NA B Hill and Smith EN1317-5:2007Springvale Business and Industrial ParkBilstonWolverhampton
N2 NR No NA B West Midlands EN1317-5:2007WV14 0QLTel: 01902 499400Fax: 01902 499419
N2 NR No NA B Email: technical@hill-smith.co.uk EN1317-5:2007Web: www.hill-smith.co.uk
H1 0.7 No NR B EN1317-5:2007+A1:2008
H1 NR No NR B EN1317-5:2007
H2 NR No NR B EN1317-5:2007
N2 NR No NA C Hill and Smith EN1317-5:2007Springvale Business and Industrial ParkBilstonWolverhampton
West MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
H2 NR No NR B Hill and Smith EN1317-5:2007+A1:2008Springvale Business and Industrial Park
W1 BilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
H2 W7 1.6 Yes VI7 A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H1 W6 1.6 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
With post centres at 5.0m the Working Width Class is: W5
With post centres at 4.0m the Working Width Class is: W4
With post centres at 4.8m the Working Width Class is: W4
With post centres at 1.6m the Working Width Class is: W1
With post centres at 2.0m the Working Width Class is: W5
With post centres at 2.0m the Working Width Class is: W4
With post centres at 4.0m the Working Width Class is: W3
With post centres at 1.6m the Working Width Class is: W2
With post centres at 1.6m the Working Width Class is: W3
With post centres at 2.8m the Working Width Class is: W3
With post centres at 2.0m the Working Width Class is: W2
With post centres at 1.2m the Working Width Class is: W1
Flex-Beam PLUS Single Sided Corrugated Beam VRS
Flex-Beam PLUS-R Single Sided Corrugated Beam VRS
DDSP/1.33+SL
DDSP/4.0A
Hi Flex Safety Fence
Flex-Beam Double Sided Corrugated Beam VRS
Flex-Beam Single Sided Corrugated Beam VRS
The installation of safety barriers with an ASI Class of C must be with the agreement of the
Overseeing Organisation (refer
to TD19/06, Sections 3.6 and 3.7).
With post centres at 2.0m, Working Width Class is:
Safety Barriers (Part 1) 12 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
H1 W6 1.8 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H1 W4 1.1 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H1 W5 1.2 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H1 W5 1.4 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
N2 W3 0.6 No NA B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
N2 W1 0.5 No NA B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
N2 W4 1.1 No NA A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
N2 W4 1.3 No NA A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
N2 W5 1.6 No NA A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
N2 W5 1.6 No NA A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
N2 W5 1.5 No NA A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
ESP/2.0B
ESP/4.0 UFS-EUS
ESP/4.0
EDSP/1.33 Bw
EDSP/2.0
ESP BOS (Baum-Objektschutz)
ESP Plus W1
ESP/2.0 Plus
ESP/2.0A
DDSP/4.0B
EDSP/1.33
Safety Barriers (Part 1) 13 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
N2 W6 1.9 No NA A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W4 1.0 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W4 0.7 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W4 0.9 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W4 0.8 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W4 0.7 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W4 0.7 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W4 0.7 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W4 1.1 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W4 0.7 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W4 1.1 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
Super Rail Eco MÜF
Super Rail
Super Rail BW
Super Rail doppelt
Super Rail Eco
Super Rail Eco 1A
Super Rail Eco doppelt - PA 2,00m
passco N2
SR Eco BW
SR Eco doppelt
SR light BW
Safety Barriers (Part 1) 14 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
H1 W3 0.8 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 8
N2 W2 0.5 No NA A 57234 Wilnsdorf EN1317-5:2007+A1:2008GermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H1 W4 1.0 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W5 1.6 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W5 0.9 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W3 0.6 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W4 1.0 No NR A Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008Dortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
H2 W3 0.5 Yes NR B PEIS Maskinfabrik A/S EN1317-5:2007+A2:2012Hobrovej 7179230 SvenstrupDenmarkTel: +45 98 38 18 50email: post@peis.dk
N2 W3 0.5 No NA B REBLOC GmbH EN1317-5:2007+A1:2008Weinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: e.list@rebloc.comWeb site: www.rebloc.com
H1 W4 0.8 No NR B REBLOC GmbH EN1317-5:2007+A1:2008Weinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: e.list@rebloc.comWeb site: www.rebloc.com
H2 W5 1.0 No NR B REBLOC GmbH EN1317-5:2007+A1:2008Weinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: e.list@rebloc.comWeb site: www.rebloc.com
H2 W1 0.0 Yes VI2 B REBLOC GmbH EN1317-5:2007+A2:2012Weinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: e.list@rebloc.comWeb site: www.rebloc.com
Super Rail ES/1,0
Super Rail ES/1,33
Super Rail light
Super Rail light auf BW
Super Rail VZB
SuperRail Eco auf Bauwerk
PEIS CE 100
REBLOC RB80_8_H2/W5
REBLOC RB80A_8_H2/W1
REBLOC RB80_8_N2/W3
REBLOC RB80_8_H1/W4
Safety Barriers (Part 1) 15 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
H2 W5 0.9 Yes VI5 B REBLOC GmbH EN1317-5:2007+A2:2012Weinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: e.list@rebloc.comWeb site: www.rebloc.com
H2 W4 0.3 Yes VI2 B REBLOC GmbH EN1317-5:2007+A2:2012Weinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: e.list@rebloc.comWeb site: www.rebloc.com
N2 W7 2.1 No NA A Rondino EN1317-5:2007+A1:2008Rue de l’IndustrieB.P.195 - Savigneux42604 MONTBRISONFRANCETel: (+33) 4 77 96 29 70 .Fax: (+33) 4 77 96 29 90/95email: m.gallien@rondino.fr
N2 W6 1.7 No NA A Rondino EN1317-5:2007+A1:2008Rue de l’IndustrieB.P.195 - Savigneux42604 MONTBRISONFRANCETel: (+33) 4 77 96 29 70 .Fax: (+33) 4 77 96 29 90/95email: m.gallien@rondino.fr
H2 W4 1.0 No NR B Rondino EN1317-5:2007+A1:2008Rue de l’IndustrieB.P.195 - Savigneux42604 MONTBRISONFRANCETel: (+33) 4 77 96 29 70 .Fax: (+33) 4 77 96 29 90/95email: m.gallien@rondino.fr
N2 W7 2.2 No NA A Rondino EN1317-5:2007+A1:2008Rue de l’IndustrieB.P.195 - Savigneux42604 MONTBRISONFRANCETel: (+33) 4 77 96 29 70 .Fax: (+33) 4 77 96 29 90/95email: m.gallien@rondino.fr
N2 W5 1.6 No NA A Rondino EN1317-5:2007+A1:2008Rue de l’IndustrieB.P.195 - Savigneux42604 MONTBRISONFRANCETel: (+33) 4 77 96 29 70 .Fax: (+33) 4 77 96 29 90/95email: m.gallien@rondino.fr
N2 W4 1.0 No NA A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby Vale
H1 W5 1.2 No NR A Enterprise Park EN1317-5:2007+A1:2008Manaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
N2 1.3 No NA A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
N2 W4 1.3 No NA A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
With post centres at 4.0m the Working Width Class is: W4
GH2
Birsta 1P Guardrail
G4M+
G2M+
Whilst the name of the system is 'Birsta
W2', it is a W4 system
ESP 2.0 (A)
MegaRail (Birsta W2)
G4M
G2M
REBLOC NB100/300_8_H2/W4
REBLOC RB100_2_H2/W5
Safety Barriers (Part 1) 16 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
N2 W5 1.6 No NA A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
N2 W1 0.5 No NA B SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
H1 W2 0.6 Yes NR A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
H2 W3 0.8 No NR B SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
H2 W5 1.6 No NR A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
H2 W4 0.6 No NR B SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
N2 W3 1.0 No NA B SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
H2 W4 1.0 Yes NR A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
H1 W3 0.7 Yes NR A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
MegaRail ec 4.4
MegaRail db (Double Sided)
MegaRail ek
ESP 4.0 (A & B)
ESP Plus W1
MegaRail bs
MegaRail bw
MegaRail e
Safety Barriers (Part 1) 17 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
H1 W4 1.2 Yes VI4 A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
N2 W3 0.9 Yes NA A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
H1 W3 0.9 Yes VI7 A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
H1 W3 0.7 Yes VI4 A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
H2 W2 0.6 Yes VI2 A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
N2 W3 0.8 Yes NA A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
N2 W3 0.9 Yes NA A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
N2 W4 1.2 Yes NA A SafeRoad UK Ltd. EN1317-5:2007+A2:2012Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
N2 W2 0.7 Yes NA A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
MegaRail eb
MegaRail eb
MegaRail sk
VIK CC4-W3
MegaRail em
MegaRail es
MegaRail en
MegaRail eb
Vik CC2-W3
Safety Barriers (Part 1) 18 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
H2 W4 1.0 No NR B SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby Vale
H3 W4 0.8 Yes NR B Enterprise Park EN1317-5:2007+A1:2008Manaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
H1 W4 1.1 No NR A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby Vale
N2 W4 1.1 No NA A Enterprise Park EN1317-5:2007+A1:2008Manaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
H2 W2 0.4 No NR B SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
H1 W3 0.8 No NR A SafeRoad UK Ltd. EN1317-5:2007+A1:2008Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
N2 NR No NA A Tata Steel Construction Products EN1317-5:2007Llanwern WorksNewportSouth Wales
N2 NR No NA A NP19 4QZ EN1317-5:2007Tel. 01633 290011 email: cep.sales@tatasteel.com
N2 NR No NA B EN1317-5:2007
N2 NR NR NA C Tata Steel Tubes EuropePO Box 101Weldon RoadCorby
N2 NR NR NA B NorthantsNN17 5UATel. 01536 402121email:marketing@tatasteel.com
N2 NR NR NA B
N2 NR NR NA B Tata Steel Tubes EuropePO Box 101Weldon RoadCorby
N2 NR NR NA B NorthantsNN17 5UATel. 01536 402121email:marketing@tatasteel.com
With post centres at 4.0m the Working Width Class is: W3
Protect 365 N2 Safety Fence (socketed)
Steel Step Barrier
Super Rail ES 1.0
With post centres at 2.0m the Working Width Class is: W1
Protect 365 N2 Safety Fence (surface mounted)
MegaRail s
MegaRail sl
With post centres at 4 and 4.375m the Working Width Class is: W3
With post centres at 3.0m the Working Width Class is: W2
With post centres at 2.0m the Working Width Class is: W1
With post centres at 3.5m the Working Width Class is: W4
With post centres at 3.2m the Working Width Class is: W3
With post centres at 3.0m the Working Width Class is: W3
Tata Steel Vetex N2 Single Sided Safety Barrier
Safety Barriers (Part 1) 19 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
N2 W7 2.3 No NA A Manufacturer : EN1317-5:2007+A1:2008TERTULes bois de Tertu61160 VILLEDIEU LES BAILLEUL FRANCETel : +33 2 33 36 11 02Fax : +33 2 33 39 28 75email: er@tertu.com
Distributor: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
N2 W5 1.5 No NA A Manufacturer : EN1317-5:2007+A1:2008TERTULes bois de Tertu61160 VILLEDIEU LES BAILLEUL FRANCETel : +33 2 33 36 11 02Fax : +33 2 33 39 28 75email: er@tertu.comDistributor: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
N2 W6 1.8 No NA A Manufacturer : EN1317-5:2007+A1:2008TERTULes bois de Tertu61160 VILLEDIEU LES BAILLEUL FRANCETel : +33 2 33 36 11 02Fax : +33 2 33 39 28 75email: er@tertu.comDistributor: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
N2 W4 0.8 No NA B Manufacturer : EN1317-5:2007+A1:2008TERTU
H2 W4 0.8 No NA B Les bois de Tertu EN1317-5:2007+A1:200861160 VILLEDIEU LES BAILLEUL FRANCETel : +33 2 33 36 11 02Fax : +33 2 33 39 28 75email: er@tertu.comDistributor: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
T22 4M
T18 4M
T18 4MS2
T40
Safety Barriers (Part 1) 20 January 2015
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
N2 W6 NR No NA A Trinity Highway Products International EN1317-5:2007Crown House
H2 W8 NR No NR A Crown Street EN1317-5:2007IpswichSuffolkIP1 3HSTel. 01473 22 11 05Fax: 01473 22 11 06email: europe.sales@trin.netWeb site: www.energyabsorption.com
END OF SAFETY BARRIER SECTION - RETURN TO CONTENTS
Vulcan Safety Barrier
Safety Barriers (Part 1) 21 January 2015
SAFETY BARRIERS (PART 2)
Safety Barrier Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised? Vehicle Intrusion Class
Impact Severity Level
Name and Address of Promoter Comments
Higher Vertical Concrete Barrier (HVCB)
H4a W5 C Please contact an appropriate Manufacturer/ Contractor for details including information on construction.
The installation of safety barriers with an ASI Class of C must be
with the agreement of the Overseeing Organisation (refer to
TD19/06, Sections 3.6 and 3.7).
Vertical Concrete Barrier (VCB)
N2 W1 C Please contact an appropriate Manufacturer/ Contractor for details including information on construction.
The installation of safety barriers with an ASI Class of C must be
with the agreement of the Overseeing Organisation (refer to
TD19/06, Sections 3.6 and 3.7).
Double Rail Open Box Beam (DROBB)
H1 W4 B Please contact any of the Promoters listed below for details including information on construction, connections and transitions.
N2 With post centres at 1.2m the Working Width Class is: W4
B Please contact any of the Promoters listed below for details including information on construction, connections and transitions.
With post centres at 2.4m the Working Width Class is: W5
B
N2 With post centres at 1.2m the Working Width Class is: W4
B Please contact any of the Promoters listed below for details including information on construction, connections and transitions.
With post centres at 2.4m then the Working Width Class is: W5
B
Single Sided Tensioned Corrugated Beam (SSTCB)
N2 With post centres at 3.2m the Working Width Class is: W6
A Please contact any of the Promoters listed below for details including information on construction, connections and transitions.
Double Sided Tensioned Corrugated Beam (DSTCB)
N2 With post centres at 3.2m the Working Width Class is: W6
Unknown Please contact any of the Promoters listed below for details including information on construction, connections and transitions.
The following Safety Barriers have been successfully tested to meet the requirements of BS EN 1317 -1 and -2, but are not CE marked, and therefore can only be used on the Highways Agency Trunk Road Network for repair schemes or unless a case can be made within a Departure from Standard application.
Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.
The Safety Barriers shall comply with the manufacturer's Specification, component descriptions and Installation procedures. Further information on Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.
NA: Not ApplicableNR: Not Reported
Single Sided Open Box Beam (SSOBB)
Double Sided Open Box Beam (DSOBB)
Safety Barriers (Part 2) 22 January 2015
Clipstone Services Limited Hill and Smith Tata Steel Construction ProductsUnits J & K Springvale Business and Industrial Park Llanwern WorksClipstone Holding Centre Bilston NewportClipstone Village Wolverhampton South WalesMansfield West Midlands Tel. 01633 290011 Nottinghamshire WV14 0QL email: cep.sales@tatasteel.comNG21 9AP Tel: 01902 499400Tel. 01623 420188 Fax: 01902 499419 Tata Steel Tubes Europe
Email: technical@hill-smith.co.uk PO Box 101CPC Fencing Services Ltd Web: www.hill-smith.co.uk Weldon RoadUnit 5 Joiners Court CorbyTorworth SafeRoad UK Ltd. NorthantsRetford Dragonby Vale NN17 5UANotts Enterprise Park Tel. 01536 402121DN22 8NW Manaberg Way email:marketing@tatasteel.comTel 01777 817 700 ScunthorpeFax 01777 817 272 North Lincolnshire Versco Ltd.Email: enquiries@cpceurorail.co.uk DN15 8XF 5 Lock Lane
Tel. 01724 289119 ThorneEurorail Crash Barriers Ltd email: enquiries@saferoaduk.co.uk DoncasterUnit 5 Joiners Court DN8 5ETTorworth Tel: 01405 818458Retford email: johns.versco@btconnect.comNottsDN22 8NWTel 01777 817 700Fax 01777 817 272Email: enquiries@cpceurorail.co.uk
END OF SAFETY BARRIER SECTION - RETURN TO CONTENTS
The Promoters for the above Double Rail Open Box Beam (DROBB), Single Sided Open Box Beam (SSOBB), Double Sided Open Box Beam (DSOBB), Single Sided Tensioned Corrugated Beam (SSTCB) and Double Sided Tensioned Corrugated Beam (DSTCB) are listed below. Please contact these Promoters for all enquiries concerning these safety barrier systems and associated connections and transitions and detailed and general arrangement drawings.
Safety Barriers (Part 2) 23 January 2015
TEMPORARY SAFETY BARRIERS
Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level
Name and Address of Promoter Comments
H1 W7 B Ardee Precast Concrete LimitedTown ParksArdeeCo. LouthIrelandTel. +353 41 6856372Fax. +353 41 6857216email: info@ardeeprecastconcrete.com Web Site: www.ardeeprecastconcrete.com
N2 W5 C Ardee Precast Concrete LimitedTown ParksArdeeCo. LouthIrelandTel. +353 41 6856372Fax. +353 41 6857216email: info@ardeeprecastconcrete.com Web Site: www.ardeeprecastconcrete.com
N1 W3 A Ardee Precast Concrete LimitedTown ParksArdeeCo. LouthIrelandTel. +353 41 6856372Fax. +353 41 6857216email: info@ardeeprecastconcrete.com Web Site: www.ardeeprecastconcrete.comAsset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhampton
N2 W6 B WV14 0QLTel. 01902 499402
H2 W8 B Fax. 01902 402104email: peter.wilkinson@hill-smith.co.uk
L2 W8 B Web Site: www.asset-vrs.co.uk
The installation of temporary safety barriers with an ASI
Class of C must be with the agreement of the Overseeing
Organisation (refer to TD19/06, Sections 8.5 and
8.6).
System Spengler Transportable Double Sided Precast Concrete Barrier (height 0.81m)
Note: For a different installation length please contact the Promoter for
information concerning the Working Width of the system.
Varioguard Double Sided Safety Barrier - SYSTEM No. 1
For a tested length of 60m between end anchors, and anchored in accordance with the EN1317 compliant test,
the working width class shall be:
System Spengler Transportable Double Sided Precast Concrete Barrier (height 0.81m)
System Spengler Transportable Double Sided Precast Concrete Barrier (height 0.81m)
Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50
mph is operative.
The following Temporary Safety Barriers have been successfully tested to meet the requirements of BS EN 1317 -1 and -2 and have been accepted for use on the Highways Agency Trunk Road Network for the Containment Performance Class and Working Width Class stated below.
Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.
The Temporary Safety Barriers shall comply with the manufacturer's Specification, component descriptions and Installation procedures. Further information on Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.
Temporary Safety Barriers 24 January 2015
Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level
Name and Address of Promoter Comments
Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhampton
N2 W6 B WV14 0QLTel. 01902 499402
H2 W8 B Fax. 01902 402104email: peter.wilkinson@hill-smith.co.uk
L2 W8 B Web Site: www.asset-vrs.co.ukH1 W5 B Asset International (A Division of Hill and Smith)
Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter.wilkinson@hill-smith.co.ukWeb Site: www.asset-vrs.co.ukAsset International (A Division of Hill and Smith)Springvale Avenue
BilstonWolverhampton
N2 W5 B WV14 0QLTel. 01902 499402Fax. 01902 402104email: peter.wilkinson@hill-smith.co.ukWeb Site: www.asset-vrs.co.ukAsset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhampton
N2 W4 B WV14 0QLTel. 01902 499402Fax. 01902 402104email: peter.wilkinson@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
N2 W6 B Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402
Fax. 01902 402104email: peter.wilkinson@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
N2 W6 B Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter.wilkinson@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
For a tested length of 68m between end anchors, and anchored in accordance with the EN1317 compliant test,
the working width class shall be:
Varioguard 'Quick Joint' Steel Safety Barrier - SYSTEM No. 2
Note: For a different installation length please contact the Promoter for
information concerning the Working Width of the system.
SOLOGUARD Emergency and Maintenance Crossing Point System
For a tested length of 68m between end anchors, and anchored in accordance with the EN1317 compliant test,
the working width class shall be:
Varioguard 'Quick Joint' Double Sided Steel Safety Barrier - SYSTEM No. 5
Note: For a different installation length please contact the Promoter for
information concerning the Working Width of the system.
Note: For a different installation length please contact the Promoter for
information concerning the Working Width of the system.
For a tested length of 88m between end anchors, and anchored in accordance with the EN1317 compliant test,
the working width class shall be:
Varioguard Double Sided Steel Safety Barrier - SYSTEM No. 3
Varioguard QM Safety Barrier System - SYSTEM No. 6 - pre move
Varioguard QM Safety Barrier System - SYSTEM No. 6 - moved
Temporary Safety Barriers 25 January 2015
Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level
Name and Address of Promoter Comments
N2 W6 B Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhampton
WV14 0QLTel. 01902 499402Fax. 01902 402104email: peter.wilkinson@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
N2 W2 B Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhampton
WV14 0QLTel. 01902 499402Fax. 01902 402104email: peter.wilkinson@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
N1 W4 A DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N2 W3 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N2 W3 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N2 W4 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
ZoneGuard System 1
ZoneGuard System No. 2 - pinned at 12m centres
Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50
mph is operative.
Delta Bloc DB80/4m (K180)
Delta Bloc DB80/6m (K150S)
Delta Bloc DB65S/6m (K120S)
Delta Bloc DB80E (K150S)
Temporary Safety Barriers 26 January 2015
Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level
Name and Address of Promoter Comments
N2 W4 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N2 W5 A DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H1 W4 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H1 W6 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H1 W6 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H1 W6 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
Delta Bloc DB80/4m (K120S)
Delta Bloc SB50
Delta Bloc DB65S/6m (K120S)
Delta Bloc DB80/4m (K180)
Delta Bloc DB80/6m (K150S)
Delta Bloc DB100/6m (K280)
Temporary Safety Barriers 27 January 2015
Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level
Name and Address of Promoter Comments
H2 W5 A DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W6 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H4a W6 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N1 W4 A Eurovia Beton12, Avenue du Juillet91412 Dourdan CedexFranceTel. (33) 01 60815200/(33) 01 64593184email: fcosani@eurovia.comWeb site: www.eurovia.com
N1 W3 B Hardstaff BarriersHardstaff Traffic Barrier Services LtdHillsideGotham RoadKingston-on-SoarNottinghamNG11 0DFTel. 0115 983 2300Fax. 0115 983 0087email: info@hardstaff-barriers.co.ukWeb site: www.hardstaff-barriers.co.uk
Delta Bloc DB100S/6m (K220)
Delta Bloc DB80/6M (K180S)
Delta Bloc DB100/6m (K280)
Eurovia Beton 2m Transportable Concrete Barrier
Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50
mph is operative.
Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50
mph is operative.
Multibloc 80 Temporary Vertical Concrete Barrier
Temporary Safety Barriers 28 January 2015
Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level
Name and Address of Promoter Comments
N2 W3 C Hardstaff BarriersHardstaff Traffic Barrier Services LtdHillsideGotham RoadKingston-on-SoarNottinghamNG11 0DFTel. 0115 983 2300Fax. 0115 983 0087email: info@hardstaff-barriers.co.ukWeb site: www.hardstaff-barriers.co.uk
N2 W3 B Hardstaff BarriersHardstaff Traffic Barrier Services LtdHillsideGotham RoadKingston-on-SoarNottinghamNG11 0DFTel. 0115 983 2300Fax. 0115 983 0087email: info@hardstaff-barriers.co.ukWeb site: www.hardstaff-barriers.co.uk
H4a W6 C Hardstaff BarriersHardstaff Traffic Barrier Services LtdHillsideGotham RoadKingston-on-SoarNottinghamNG11 0DFTel. 0115 983 2300Fax. 0115 983 0087email: info@hardstaff-barriers.co.ukWeb site: www.hardstaff-barriers.co.uk
H4a W2 C Hardstaff BarriersHardstaff Traffic Barrier Services LtdHillside
Gotham RoadKingston-on-SoarNottinghamNG11 0DFTel. 0115 983 2300Fax. 0115 983 0087email: info@hardstaff-barriers.co.ukWeb site: www.hardstaff-barriers.co.uk
Multibloc 110 Freestanding Temporary Vertical Concrete Barrier
The installation of temporary safety barriers with an ASI
Class of C must be with the agreement of the Overseeing
Organisation (refer to TD19/06, Sections 8.5 and
8.6).
Multibloc Freestanding Temporary Vertical Concrete Barrier
The installation of temporary safety barriers with an ASI
Class of C must be with the agreement of the Overseeing
Organisation (refer to TD19/06, Sections 8.5 and
8.6).
Maxibloc Freestanding Temporary Higher Vertical Concrete Barrier
Maxibloc Recessed Temporary Higher Vertical Concrete Barrier
The installation of temporary safety barriers with an ASI
Class of C must be with the agreement of the Overseeing
Organisation (refer to TD19/06, Sections 8.5 and
8.6).
Temporary Safety Barriers 29 January 2015
Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level
Name and Address of Promoter Comments
N1 W8 A Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.ukHighway Care Ltd.The HighlandsDetling HillDetling
N2 W5 A MaidstoneKent
H2 W8 A ME14 3HTTel. 01622 734215
L2 W8 A Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
N2 W5 A Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
N2 W2 B Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
N2 W2 B Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
For a tested length of 72m between end anchors, and anchored in accordance with the EN1317 compliant test,
the working width class shall be:
Note: For a different installation length please contact the Promoter for
information concerning the Working Width of the system.
Highway Care BarrierGuard 800 - wheeled
Highway Care BarrierGuard 800 - 12m centres
Highway Care BarrierGuard 800
Armorzone Longitudinal Barrier (ALB) Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50
mph is operative.
Highway Care BarrierGuard 800, Minimum Deflection System (MDS)
Temporary Safety Barriers 30 January 2015
Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level
Name and Address of Promoter Comments
N2 W4 B Highway Care Ltd.The Highlands
H2 W6 B Detling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
N2 W3 C NMS Civil Engineering LimitedPark Industrial EstateLiverpool RoadAshton-in MakerfieldWiganGreater ManchesterWN4 0YUTel. 01942 722694email: Geoff@nmsltd.co.uk
N1 W7 A Oaklands Plastics LtdStation RoadColeshillBirminghamB46 1HTTel. 01675 466321email: enquiries@oaklandsplastics.com
N2 W3 B REBLOC GmbHWeinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: e.list@rebloc.comWeb site: www.rebloc.com
H1 W4 B REBLOC GmbHWeinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: e.list@rebloc.comWeb site: www.rebloc.com
H2 W5 B REBLOC GmbHWeinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: e.list@rebloc.comWeb site: www.rebloc.com
Quickchange Moveable Barrier (QMB)
NMS Civil Engineering N2TCB Freestanding Precast Concrete Barrier
The installation of temporary safety barriers with an ASI
Class of C must be with the agreement of the Overseeing
Organisation (refer to TD19/06, Sections 8.5 and
8.6).
Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50
mph is operative.
RB22 Water Filled Barrier
REBLOC RB80_8_H1/W4
REBLOC RB80_8_N2/W3
REBLOC RB80_8_H2/W5
Temporary Safety Barriers 31 January 2015
Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level
Name and Address of Promoter Comments
H2 W1 B REBLOC GmbHWeinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: e.list@rebloc.comWeb site: www.rebloc.com
H2 W5 B REBLOC GmbHWeinerstrasse 662Gars am Kamp3571 AustriaTel. +43(2985)30922-2902Fax. +43(2985)30922-2901email: e.list@rebloc.comWeb site: www.rebloc.com
N1 W8 A Rhino Barrier Systems Ltd.Equinox 1Audby LaneWetherbyWest YorkshireLS22 7RDTel. 01937 583333Fax. 01937 58322email: sales@polyjohn.co.ukWeb Site: www.rhinobarriers.comSafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg Way
H2 W8 B ScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.ukSafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg Way
N2 W6 A ScunthorpeNorth Lincolnshire
H2 W8 B DN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.ukSafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg Way
N2 W6 B ScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
For a tested length of 64m between end anchors, and anchored in accordance with the EN1317 compliant test,
the working width class shall be:
Rhino Polyethylene Water Filled Barrier System
Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50
mph is operative.
For a tested length of 68m between end anchors, and anchored in accordance with the EN1317 compliant test,
the working width class shall be:
Note: For a different installation length please contact the Promoter for
information concerning the Working Width of the system.
REBLOC RB80A_8_H2/W1
REBLOC RB100_2_H2/W5
Note: For a different installation length please contact the Promoter for
information concerning the Working Width of the system.
Varioguard 'Quick Joint' H2 Double Sided Steel Safety Barrier
Freestanding Varioguard with Quick Joints H2 Double Sided Steel Safety Barrier
Note: For a different installation length please contact the Promoter for
information concerning the Working Width of the system.
For a tested length of 64m between end anchors, and anchored in accordance with the EN1317 compliant test,
the working width class shall be:
Advanced Varioguard N2 Double Sided Steel Safety Barrier
Temporary Safety Barriers 32 January 2015
Temporary Safety Barrier Name Containment Level Working Width Class Impact Severity Level
Name and Address of Promoter Comments
N2 W6 A Trinity Highway Products InternationalCrown House
H2 W8 A Crown StreetIpswichSuffolkIP1 3HSTel. 01473 22 11 05Fax: 01473 22 11 06email: europe.sales@trin.netWeb site: www.energyabsorption.com
END OF TEMPORARY SAFETY BARRIER SECTION - RETURN TO CONTENTS
Vulcan Safety Barrier
Temporary Safety Barriers 33 January 2015
PARAPETS
Parapet Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised?
Vehicle Intrusion Class Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments CE Marked
H2 W4 1 Yes NR A Manufacturer: Marcegaglia Srl EN1317-5:2007+A1:2008 YESDistributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
H2 W4 0.7 No NR B Pass and Co Barrier Systems GMBH EN1317-5:2007+A1:2008 YESDortmunderstrasse 857234 WilnsdorfGermanyTel: +49 (0)2739 4796-0Fax: +49 (0)2739 4796-110email: j.m.hiekmann@passco.de
N2 NR No NA B SafeRoad UK Ltd. EN1317-5:2007+A1:2008 YES
Dragonby Vale
W1 Enterprise Park
Manaberg Way
H2 NR No NR B Scunthorpe EN1317-5:2007+A1:2008 YES
North Lincolnshire
W1 DN15 8XF
Tel. 01724 289119
H1 email: enquiries@saferoaduk.co.uk
H2 W2 0.5 No NR B SafeRoad UK Ltd. EN1317-5:2007+A1:2008 YES
Dragonby Vale
Enterprise Park
Manaberg Way
Scunthorpe
North Lincolnshire
DN15 8XF
Tel. 01724 289119
email: enquiries@saferoaduk.co.uk
N1 NR No NA A SafeRoad UK Ltd. EN1317-5:2007+A1:2008 YES
Dragonby ValeW2 Enterprise Park
Manaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
N2 NR No NA B SafeRoad UK Ltd. EN1317-5:2007+A1:2008 YES
Dragonby Vale
W3 Enterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
The following Parapets have been successfully tested to meet the requirements of BS EN 1317 -1 and -2 and the HA has been advised that they have been CE marked in accordance with the Construction Products Regulation (CPR) for the Containment Performance Class and Working Width Class stated below.
Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.
The parapets shall comply with the manufacturer's Specification, component descriptions and Installation procedures. Further information on Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.
NA: Not ApplicableNR: Not Reported
Note: Only permitted for use on roads where a speed limit of
less than 50 mph is operative.
H2BP-MARC2011 bridge parapet
Super Rail BW
MegaGuard H2 Steel parapet (1.25m high)
Orsta Bridge Parapet
Phoenix N1 Aluminium Parapet
Phoenix N2 Aluminium Parapet
With post centres at 2.0m the Working Width Class is:
With post centres at 3.8m the Working Width Class is:
With post centres at 3.0m the Working Width Class is:
With post centres at 2.0m the Working Width Class is:
Parapets 34 January 2015
Parapet Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised?
Vehicle Intrusion Class Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments CE Marked
N2 NR No NA B SafeRoad UK Ltd. EN1317-5:2007+A1:2008 YESDragonby Vale
W4 Enterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
H2 W2 0.4 No NR B SafeRoad UK Ltd. EN1317-5:2007+A1:2008 YESDragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
N1 NA A Tata Steel Tubes Europe YESPO Box 101
W1 Weldon RoadCorby
N1 NA A Northants YESNN17 5UA
W2 Tel. 01536 402121email:marketing@tatasteel.com
N2 NA B Tata Steel Tubes Europe YESPO Box 101
W3 Weldon RoadCorby
N2 NA B Northants YESNN17 5UA
W4 Tel. 01536 402121email:marketing@tatasteel.com
L4a/H4a VI4 B Tata Steel Tubes Europe YESPO Box 101
W4 Weldon RoadCorbyNorthantsNN17 5UATel. 01536 402121email:marketing@tatasteel.com
H4a Yes VI6 C Tata Steel Tubes Europe YESPO Box 101
W4 Weldon RoadCorby
H4a Yes VI6 B Northants YESNN17 5UA
W4 Tel. 01536 402121email:marketing@tatasteel.com
N1 NA A Tata Steel Tubes Europe YESPO Box 101
W1 Weldon RoadCorbyNorthantsNN17 5UATel. 01536 402121email:marketing@tatasteel.com
H2 W5 1.3 No NR B Manufacturer : EN1317-5:2007+A1:2008 YESTERTULes bois de Tertu61160 VILLEDIEU LES BAILLEUL FRANCETel : +33 2 33 36 11 02Fax : +33 2 33 39 28 75email: er@tertu.comDistributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
Note: Only permitted for use on roads where a speed limit of
less than 50 mph is operative.
Note: Only permitted for use on roads where a speed limit of
less than 50 mph is operative.
Note: For intermediate post positions the
manufacturer/Promoter will be responsible for declaring the
working width.
Protect 365 N2 parapet(formerlyCorus HBP 300 N2 Steel Parapet)
Protect 365 Clad L4a/H4a Parapet(formerly Corus Tubes Celsius HBP 300 H4a Steel Parapet)
Protect 365 Unclad H4a Parapet
The installation of parapets with an ASI Class of C must be with
the agreement of the Overseeing Organisation (refer to TD19/06,
Sections 4.11 and 4.12).With post centres between 3.5m and 4.375m the Working Width Class is:
Protect 365 N1 Parapet
(formerly Corus Protect 365 N1 3 Rail Steel Parapet)
Protect 365 N1 Vertical Infill Steel Parapet
T40 4MS2 Bridge Parapet
With post centres between 2.5m and 3.49m the Working Width Class is:
With post centres at 2.5m to 3.75m the Working Width Class is:
SN2 steel parapet
Sicuro Arc Bridge Parapet
With post centres at 3.75m the Working Width Class is:
With post centres at 2.5 to 2.99m the Working Width Class is:
With post centres at 3.0 to 3.75m the Working Width Class is:
With post centres at 2.5 to 3.75m the Working Width Class is:
With post centres at 2.5 to 3.49m the Working Width Class is:
With post centres at 2.5 to 3.75 m the Working Width Class is:
Parapets 35 January 2015
Parapet Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised?
Vehicle Intrusion Class Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments CE Marked
N1 W2 NR Yes NA A Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred StreetSparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: darren@v-and-g.co.uk
N2 No NA B Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street
W2 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: darren@v-and-g.co.uk
N2 No NA B Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street
W1 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: darren@v-and-g.co.uk
N2 NR No NA C Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street
W2 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: darren@v-and-g.co.uk
N1 NR No NA A Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street
W1 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: darren@v-and-g.co.uk
N1 NR No NA A Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street
W2 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: darren@v-and-g.co.uk
H2 NR No NR B Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street
W1 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: darren@v-and-g.co.uk
H2 NR No NR B Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street
W3 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: darren@v-and-g.co.uk
H4a NR No NR B Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street
W4 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: darren@v-and-g.co.uk
H4a NR No NR B Varley and Gulliver Ltd EN1317-5:2007+A1:2008 YESAlfred Street
W3 SparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: darren@v-and-g.co.uk
Note: Only permitted for use on roads where a speed limit of
less than 50 mph is operative.
Note: Only permitted for use on roads where a speed limit of
less than 50 mph is operative.
VGSH 2000 H2 Steel Parapet
VGSH 4000 Steel Parapet
V6Guard H4a Steel Parapet
VGSN 500 N1 Steel Parapet
VGAN 500 N1 Aluminium Parapet
VarleyGuard Steel Parapet
With post centres at 3.6 to 4.5m, Working Width Class is:
VGAN 800 N1 Aluminium Parapet
The installation of parapets with an ASI Class of C must be with
the agreement of the Overseeing Organisation (refer to TD19/06,
Sections 4.11 and 4.12).
VGAN 1000 N2 Aluminium Parapet
VGSN 1000 N2 Steel Parapet
VGSN 900 N2 Steel Parapet
With post centres at 1.5m the Working Width Class is:
With post centres at 3.0 to 3.75m, Working Width Class is:
With post centres at 2.93 to 3.66m, Working Width Class is:
With post centres at 2.93 to 3.66m, Working Width Class is:
With post centres at 1.8 to 2.0m, Working Width Class is:
With post centres at 2.7 to 3.0m, Working Width Class is:
With post centres at 3.6 to 4.0m, Working Width Class is:
With post centres at 2.0m, Working Width Class is:
Parapets 36 January 2015
Parapet Name Containment Level Working Width Class Dynamic Deflection (m) Are DD and WW normalised?
Vehicle Intrusion Class Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments CE Marked
H2 W1 0.4 Yes VI2 B VeRSco Ltd EN1317-5:2007+A1:2008 YESUnit 5Lock LaneThorneSouth YorkshireDN8 5ETTel. 07907 268 376email: Fjrsmithy@aol.com
END OF PARAPET SECTION - RETURN TO CONTENTS
Note: Although this is called the VC/H2W1 parapet, it has a VI
class of V12.
VC/H2W1
Parapets 37 January 2015
CRASH CUSHIONS
Crash Cushion Name Performance Level Redirection Zone and Lateral Displacement Classes
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
100km/h Re - Direction Zone Class - Z4 B Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale Avenue
Lateral Displacement Zone Class - D2 BilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
110km/h Re - Direction Zone Class - Z3 B Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale Avenue
Lateral Displacement Zone Class - D1 BilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
110km/h Re - Direction Zone Class - Z3 B Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale Avenue
Lateral Displacement Zone Class - D1 BilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
100km/h Re - Direction Zone Class - Z4 B Asset International (A Division of Hill and Smith) EN1317-5:2007+A1:2008Springvale Avenue
Lateral Displacement Zone Class - D2 BilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
100km/h Re - Direction Zone Class - Z4 B Asset International (A Division of Hill and Smith) Not applicable - temporary use onlySpringvale Avenue
Lateral Displacement Zone Class - D2 BilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
110 km/h Redirection zone class - Z1 A Asset International (a division of Hill & Smith) EN1317-5:2007Lateral displacement zone class - D1 Springvale Avenue
Bilston, WolverhamptonWV14 0QL
80 km/h Redirection zone class - Z1 A Tel: 01902 499402Lateral displacement zone class - D1 Fax: 01902 402104
email: peter@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
For use on roads with a speed limit of 50mph or less
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit of 50mph or less
For use on roads with a speed limit greater than 50mph
The following Crash Cushions have been successfully tested to meet the requirements of BS EN 1317 - 3 and the HA has been advised that they have been CE marked in accordance with the Construction Products Regulation (CPR) for the Performance Level and Zone Classes stated below.
Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.
The Crash Cushions shall comply with the manufacturer's Specification, component descriptions and Installation procedures. Copies of documents and drawings can be obtained from the Promoter.
Vecu-Stop Re-Directional and Bi-Directional Crash Cushion - Model P120/2:13 and V120/4:13
Vecu-Stop Re-Directional and Bi-Directional Crash Cushion - Model P120/2:14 and V120/4:14
Vecu-Stop Re-Directional and Bi-Directional Crash Cushion - Model P100/2:14 and V100/4:14
Vecu-Stop Re-Directional and Bi-Directional Crash Cushion - Model P100/2:13 and V100/4:13
EuroTRACC 110 re-directional and bi-directional crash cushion
EuroTRACC 80 re-directional and bi-directional crash cushion
Vecu-Stop Temporary Crash Cushion
For use on roads with a speed limit of 50mph or less
Crash Cushions 38 January 2015
Crash Cushion Name Performance Level Redirection Zone and Lateral Displacement Classes
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
110 km/h Redirection zone class - Z1 B Asset International (a division of Hill & Smith) EN1317-5:2007Lateral displacement zone class - D1 Springvale Avenue
Bilston, WolverhamptonWV14 0QL
80 km/h Redirection zone class - Z1 B Tel: 01902 499402Lateral displacement zone class - D1 Fax: 01902 402104
email: peter@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
110 km/h Redirection zone class - Z1 B Asset International (a division of Hill & Smith) EN1317-5:2007+A1:2008Lateral displacement zone class - D1 Springvale Avenue
100 km/h Redirection zone class - Z1 B Bilston, WolverhamptonLateral displacement zone class - D1 WV14 0QL
80 km/h Redirection zone class - Z1 B Tel: 01902 499402Lateral displacement zone class - D1 Fax: 01902 402104
50 km/h Redirection zone class - Z1 B email: customer-enquiry@hill-smith.co.ukLateral displacement zone class - D1 Web Site: www.asset-vrs.co.uk
110 km/h Redirection zone class - Z2 B Asset International (a division of Hill & Smith) EN1317-5:2007Lateral displacement zone class - D2 Springvale Avenue
100 km/h Redirection zone class - Z2 B Bilston, WolverhamptonLateral displacement zone class - D2 WV14 0QL
80 km/h Redirection zone class - Z1 A Tel: 01902 499402Lateral displacement zone class - D1 Fax: 01902 402104
email: customer-enquiry@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
110km/h Re - Direction Zone Class - Z1 B Highway Care Ltd.Lateral Displacement Zone Class - D1 The Highlands
100km/h Re - Direction Zone Class - Z1 B Detling HillLateral Displacement Zone Class - D1 Detling
80km/h Re - Direction Zone Class - Z1 B MaidstoneLateral Displacement Zone Class - D1 Kent
50km/h Re - Direction Zone Class - Z1 B ME14 3HTLateral Displacement Zone Class - D1 Tel. 01622 734215
Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
110km/h Re - Direction Zone Class - Z1 B Highway Care Ltd.Lateral Displacement Zone Class - D1 The Highlands
100km/h Re - Direction Zone Class - Z1 B Detling HillLateral Displacement Zone Class - D1 Detling
80km/h Re - Direction Zone Class - Z1 B MaidstoneLateral Displacement Zone Class - D1 Kent
50km/h Re - Direction Zone Class - Z1 B ME14 3HTLateral Displacement Zone Class - D1 Tel. 01622 734215
Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
110km/h Re - Direction Zone Class - Z1 B Highway Care Ltd.Lateral Displacement Zone Class - D1 The Highlands
100km/h Re - Direction Zone Class - Z1 B Detling HillLateral Displacement Zone Class - D1 Detling
80km/h Re - Direction Zone Class - Z1 B MaidstoneLateral Displacement Zone Class - D1 Kent
50km/h Re - Direction Zone Class - Z1 B ME14 3HTLateral Displacement Zone Class - D1 Tel. 01622 734215
Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
For use on roads with a speed limit of 50mph or less
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit of 50mph or less
For use on roads with a speed limit greater than 50mph
EuroTRACC 80 Wide re-directional and bi-directional crash cushion
QuadGuard™ CEN re-directional and bi-directional crash cushion
Quest™ CEN re-directional and bi-directional crash cushion
TAU Bi-Directional and Re-Directional Parallel Crash Cushions
TAU Bi-Directional and Re-Directional Medium Crash Cushions
TAU Bi-Directional and Re-Directional Large Crash Cushions
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit of 50mph or less
EuroTRACC 110 Wide re-directional and bi-directional crash cushion
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit of 50mph or less
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit of 50mph or less
Crash Cushions 39 January 2015
Crash Cushion Name Performance Level Redirection Zone and Lateral Displacement Classes
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
110km/h Re - Direction Zone Class - Z1 B Highway Care Ltd.Lateral Displacement Zone Class - D1 The Highlands
100km/h Re - Direction Zone Class - Z1 B Detling HillLateral Displacement Zone Class - D1 Detling
80km/h Re - Direction Zone Class - Z1 B MaidstoneLateral Displacement Zone Class - D1 Kent
50km/h Re - Direction Zone Class - Z1 B ME14 3HTLateral Displacement Zone Class - D1 Tel. 01622 734215
Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
110km/h Re - Direction Zone Class - Z2 B Highway Care Ltd.Lateral Displacement Zone Class - D1 The Highlands
Detling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
110km/h Re - Direction Zone Class - Z1 B Industry AMS SrlLateral Displacement Zone Class - D4 Via Eduardo De Filippo, 11
100km/h Re - Direction Zone Class - Z1 B 80013 CasalnuovoLateral Displacement Zone Class - D4 Italy
80km/h Re - Direction Zone Class - Z1 B Tel: 0823 821560Lateral Displacement Zone Class - D4 Fax: 0823 821067
50km/h Re - Direction Zone Class - Z1 B email: r.impero@amssrl.comLateral Displacement Zone Class - D4 web site: www.smaroadsafety.com
110km/h Re - Direction Zone Class - Z1 B Industry AMS SrlLateral Displacement Zone Class - D4 Via Eduardo De Filippo, 11
100km/h Re - Direction Zone Class - Z1 B 80013 CasalnuovoLateral Displacement Zone Class - D4 Italy
80km/h Re - Direction Zone Class - Z1 B Tel: 0823 821560Lateral Displacement Zone Class - D4 Fax: 0823 821067
email: r.impero@amssrl.comweb site: www.smaroadsafety.com
110km/h Re - Direction Zone Class - Z1 B Industry AMS SrlLateral Displacement Zone Class - D4 Via Eduardo De Filippo, 11
100km/h Re - Direction Zone Class - Z1 B 80013 CasalnuovoLateral Displacement Zone Class - D4 Italy
80km/h Re - Direction Zone Class - Z1 B Tel: 0823 821560Lateral Displacement Zone Class - D4 Fax: 0823 821067
50km/h Re - Direction Zone Class - Z1 B email: r.impero@amssrl.comLateral Displacement Zone Class - D4 web site: www.smaroadsafety.com
110km/h Re - Direction Zone Class - Z1 B Industry AMS SrlLateral Displacement Zone Class - D4 Via Eduardo De Filippo, 11
100km/h Re - Direction Zone Class - Z1 B 80013 CasalnuovoLateral Displacement Zone Class - D4 Italy
80km/h Re - Direction Zone Class - Z1 B Tel: 0823 821560Lateral Displacement Zone Class - D4 Fax: 0823 821067
email: r.impero@amssrl.comweb site: www.smaroadsafety.com
110km/h Re - Direction Zone Class - Z1 B Industry AMS SrlLateral Displacement Zone Class - D4 Via Eduardo De Filippo, 11
100km/h Re - Direction Zone Class - Z1 B 80013 CasalnuovoLateral Displacement Zone Class - D4 Italy
80km/h Re - Direction Zone Class - Z1 B Tel: 0823 821560Lateral Displacement Zone Class - D4 Fax: 0823 821067
email: r.impero@amssrl.comweb site: www.smaroadsafety.com
TAU Bi-Directional and Re-Directional X-Large Crash Cushions
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit of 50mph or less
For use on roads with a speed limit of 50mph or less
SMA SEMI-WIDE Crash Cushions
For use on roads with a speed limit greater than 50mph
TAU Tube P110 Crash Cushion
SMA Crash Cushions For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit of 50mph or less
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit of 50mph or less
SMA WL Crash Cushions For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit of 50mph or less
For use on roads with a speed limit greater than 50mph
SMA SLIM Crash Cushions
For use on roads with a speed limit of 50mph or less
SMA WIDE Crash Cushions For use on roads with a speed limit greater than 50mph
Crash Cushions 40 January 2015
Crash Cushion Name Performance Level Redirection Zone and Lateral Displacement Classes
Impact Severity Level
Name and Address of Promoter Version of EN1317-5 to which the system was CE marked
Comments
110km/h Re - Direction Zone Class - Z4 B Shindo Industry Co Ltd EN1317-5:2007+A1:2008Lateral Displacement Zone Class - D6 922-3 Dongpae-Ri
Gyoha-eup100km/h Re - Direction Zone Class - Z2 B Paju-city
Lateral Displacement Zone Class - D1 Gyeonggi-Do413-834
80km/h Re - Direction Zone Class - Z1 B KoreaLateral Displacement Zone Class - D1 Tel: 82-31-9438008
Fax: 82-31-949001350km/h Re - Direction Zone Class - Z1 B Email: trading@moosago.com
Lateral Displacement Zone Class - D1110km/h Re - Direction Zone Class - Z2 A Shindo Industry Co Ltd EN1317-5:2007+A1:2008
Lateral Displacement Zone Class - D1 922-3 Dongpae-RiGyoha-eup
100km/h Re - Direction Zone Class - Z2 A Paju-cityLateral Displacement Zone Class - D1 Gyeonggi-Do
413-83480km/h Re - Direction Zone Class - Z1 A Korea
Lateral Displacement Zone Class - D1 Tel: 82-31-9438008Fax: 82-31-9490013
50km/h Re - Direction Zone Class - Z1 A Email: trading@moosago.comLateral Displacement Zone Class - D1
110 km/h Redirection zone class - Z1 A Trinity Highway Products International EN1317-5:2007Lateral displacement zone class - D1 Crown House, Crown Street
IpswichIP1 3HS
80 km/h Redirection zone class - Z1 A Tel: 01473 221105Lateral displacement zone class - D1 Fax: 01473 221106
Email: europe.sales@trin.netWebsite: www.highwayguardrail.com
110 km/h Redirection zone class - Z1 B Trinity Highway Products International EN1317-5:2007Lateral displacement zone class - D1 Crown House, Crown Street
IpswichIP1 3HS
80 km/h Redirection zone class - Z1 B Tel: 01473 221105Lateral displacement zone class - D1 Fax: 01473 221106
Email: europe.sales@trin.netWebsite: www.highwayguardrail.com
110 km/h Redirection zone class - Z1 B Trinity Highway Products International EN1317-5:2007+A1:2008Lateral displacement zone class - D1 Crown House, Crown Street
100 km/h Redirection zone class - Z1 B IpswichLateral displacement zone class - D1 IP1 3HS
80 km/h Redirection zone class - Z1 B Tel: 01473 221105Lateral displacement zone class - D1 Fax: 01473 221106
50 km/h Redirection zone class - Z1 B Email: europe.sales@trin.netLateral displacement zone class - D1 Website: www.energyabsorption.com
110 km/h Redirection zone class - Z2 B Trinity Highway Products International EN1317-5:2007Lateral displacement zone class - D2 Crown House, Crown Street
100 km/h Redirection zone class - Z2 B IpswichLateral displacement zone class - D2 IP1 3HS
80 km/h Redirection zone class - Z1 A Tel: 01473 221105Lateral displacement zone class - D1 Fax: 01473 221106
Email: europe.sales@trin.netWebsite: www.energyabsorption.com
100 km/h Redirection zone class - Z1 A Trinity Highway Products International EN1317-5:2007Crown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: europe.sales@trin.netWebsite: www.energyabsorption.com
END OF CRASH CUSHION SECTION - RETURN TO CONTENTS
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit of 50mph or less
EuroTRACC 110 re-directional and bi-directional crash cushion
EuroTRACC 80 re-directional and bi-directional crash cushion
EuroTRACC 110 Wide re-directional and bi-directional crash cushion
EuroTRACC 80 Wide re-directional and bi-directional crash cushion
QuadGuard™ CEN re-directional and bi-directional crash cushion
Quest™ CEN re-directional and bi-directional crash cushion
EU CCS II
For use on roads with a speed limit of 50mph or less
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit of 50mph or less
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit of 50mph or less
For use on roads with a speed limit greater than 50mph
For use on roads with a speed limit of 50mph or less
Fitch Universal Module System
Cushion Tank System
Crash Cushions 41 January 2015
TERMINALS
Terminal Name Performance Class PLDZ Class Exit Box Class/Vehicle Redirection Zone
Impact Severity Level
Name and Address of Promoter Comments
P4 D2.4 Z2 B Acklea Ltd/Traffix DevicesUnit 1Clark AvenuePorte Marsh Industrial EstateClaneWiltshireSN11 9RDTel. 01249 822 600Fax. 01249 820 111email: andy.dougan@acklea.biz
P4 D2.4 Z2 B Acklea Ltd/Traffix DevicesUnit 1Clark AvenuePorte Marsh Industrial EstateClaneWiltshire
SN11 9RDTel. 01249 822 600Fax. 01249 820 111email: andy.dougan@acklea.biz
P4 D.1.1 Z1 A Brifen (A Division of Hill and Smith)Springvale Business and Industrial ParkBilstonWolverhampton
West MidlandsWV14 0QL
H1 Tel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
50mph or more
The following Terminals for safety barriers have been successfully tested to meet the requirements of DD ENV 1317 - 4 and have been accepted for use on the Highways Agency Trunk Road Network for the Performance Class and Permanent Lateral Displacement Zone (PLDZ) Class Code stated below.
The Terminals shall comply with the manufacturer's Specification, component descriptions and Installation procedures. Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in
the DMRB, MCHW, and any contract specific or site specific documentation.Additional information on Exit Box and Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.
Installers shall have successfully undertaken suitable training for the system to be installed.
Note: please refer to Table 6, DD ENV 1317 - 4 for PLDZ and Class Codes for terminals. The values of Displacement (measured in metres) Da and Dd are converted to Class Code x and y. Therefore Class Code D1.1 (where 'D' is displacement) represents 0.5m displacement (x), measured from the traffic face of the barrier towards the traffic, and 1.0m (y) measured from the
traffic face of the barrier to the rear of the barrier. D1.3 represents a displacement of 0.5m in front of the barrier and 3.5m to the rear of the barrier.
SLED Euro terminal (connected to VarioGuard)
SLED Euro terminal (connected to BarrierGuard)
Brifen P4 Wire Rope End Terminal for Brifen 4 Rope Safety Fence
50mph or more
50mph or more
Terminals 42 January 2015
Terminal Name Performance Class PLDZ Class Exit Box Class/Vehicle Redirection Zone
Impact Severity Level
Name and Address of Promoter Comments
P4 D.1.1 Z1 A Brifen (A Division of Hill and Smith)Springvale Business and Industrial ParkBilston
WolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
P4 D.1.1 Z2 B Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
P4 D.1.1 Z2 B Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
P4 D.1.1 Z2 B Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
Double Sided Xtension P4 Terminal connected to Double Sided Flexbeam N2W1, N2W2 or N2W3 safety barrier
Brifen P4 Wire Rope End Terminal for Brifen 3 Rope Safety Fence
Single Sided Xtension P4 Terminal (Xtension 110 Terminal)
Double Sided Xtension P4 Terminal (also known as the X-Tension 110 Double Sided P4 Terminal (XT-DS110))
50mph or more
50mph or more
50mph or more
50mph or more
Terminals 43 January 2015
Terminal Name Performance Class PLDZ Class Exit Box Class/Vehicle Redirection Zone
Impact Severity Level
Name and Address of Promoter Comments
P4 D.1.1 Z2 B Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
P4 D.1.1 Z2 B Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
P4 D.1.1 Z1 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
P4 D.1.3 Z1 A Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
Euro ET End Terminal
Double Sided Xtension P4 Terminal connected to Vetex Double Sided N2W1, N2W2 or N2W3 safety barrier
ABC Terminal
Double Sided Xtension P4 Terminal connected to Vetex Single Sided N2W1, N2W2 or N2W3 safety barrier
50mph or more, verge only
50mph or more
50mph or more
50mph or more
Terminals 44 January 2015
Terminal Name Performance Class PLDZ Class Exit Box Class/Vehicle Redirection Zone
Impact Severity Level
Name and Address of Promoter Comments
P1 D.1.1 Z1 A Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
P1 D.1.1 Z1 A Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
P1 D.1.1 Z1 A Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
P4 D2.3 Z1 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
P4 D.1.1 Z2 A Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
TREND CEN End Terminal
Flex-Beam Double Sided P1 End Terminal
Flex-Beam Single Sided P1 End Terminal
Hill and Smith 'Safety Line' Wire Rope Safety Fence Terminal
Euro BXT Terminal
Less than 50mph, or on the departure end of a safety barrier not facing oncoming traffic where
the speed limit is 50mph or more.
50 mph or more
Less than 50mph, or on the departure end of a safety barrier not facing oncoming traffic where
the speed limit is 50mph or more.
50mph or more
Less than 50mph, or on the departure end of a safety barrier not facing oncoming traffic where
the speed limit is 50mph or more.
Terminals 45 January 2015
Terminal Name Performance Class PLDZ Class Exit Box Class/Vehicle Redirection Zone
Impact Severity Level
Name and Address of Promoter Comments
P4 D.1.1 Z2 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
P4 D1.2 Z1 B Distributed by: Ferrostrada (UK) LimitedVenlaw HouseBurston RoadHeywoodSouth NorfolkIP22 5SXWeb site: www.ferrostrada-uk.comTel: 01379 308 051Fax: 01379 308 053Email: jferro@ferrostrada-uk.comContact: Jason Ferro
P1 D1.1 Z1 A SafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
P4 D1.1 Z1 B SafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
P4 D1.1 Z1 B SafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
TREND CEN DS Double Sided End Terminal
SafeEnd T110
SafeEnd P1 terminal
Sistema P4 Performance Terminal
50mph or more
Less than 50mph, or on the departure end of a safety barrier not facing oncoming traffic where
the speed limit is 50mph or more.
50mph or more
50 mph or more
SafeEnd P4 50mph or more
Terminals 46 January 2015
Terminal Name Performance Class PLDZ Class Exit Box Class/Vehicle Redirection Zone
Impact Severity Level
Name and Address of Promoter Comments
P1 D.1.1 Z1 A Tata Steel Construction ProductsLlanwern WorksNewportSouth WalesNP19 4QZTel. 01633 290011 email: cep.sales@tatasteel.com
P4 D.1.1 Z2 A Trinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: europe.sales@trin.netWebsite: www.energyabsorption.com
P4 D.1.1 Z2 B Trinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: europe.sales@trin.netWebsite: www.energyabsorption.com
P4 D.1.3 Z1 A Trinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: europe.sales@trin.netWebsite: www.highwayguardrail.com
P4 D2.3 Z1 B Trinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: europe.sales@trin.netWebsite: www.highwayguardrail.com
TREND CEN DS Double Sided End Terminal
Euro ET End Terminal
TREND CEN End Terminal
50 mph or more, verge only
50 mph or more
50 mph or more
Less than 50mph, or on the departure end of a safety barrier not facing oncoming traffic where
the speed limit is 50mph or more.
Euro BXT End Terminal
50 mph or more
Tata Steel Vetex P1 End Terminal
Terminals 47 January 2015
Terminal Name Performance Class PLDZ Class Exit Box Class/Vehicle Redirection Zone
Impact Severity Level
Name and Address of Promoter Comments
P4 D.1.1 Z1 B Trinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: europe.sales@trin.net
Website: www.energyabsorption.com
END OF TERMINAL SECTION - RETURN TO CONTENTS
ABC End Terminal
Terminals detailed in the NPSBS, such as those for TCB and OBB, are deemed acceptable for use on the Highways Agency Trunk Road Network on roads with a speed limit less than 50 mph. In addition the terminals can be used on the departure end of safety barriers where the terminal does not face oncoming traffic and the speed limit is 50mph or more.
These terminals do not need a Departure from Standard submission, as they have proven in-service use over a number of years. Please contact the Promoter's of DROBB, OBB and TCB listed in the Safety Barrier section for further information.
Installers shall have successfully undertaken suitable training for the system to be installed.
50 mph or more
Terminals 48 January 2015
TRANSITIONS
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
N2 W2 B Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
N2 Contact the promotor Contact the promotor Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
N2 Contact the promotor Contact the promotor Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
H1 Contact the promotor Contact the promotor Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
The following Transitions have been successfully tested and/or independantly assessed against the requirements of ENV 1317 - 4 and have been accepted for use on the Highways Agency Trunk Road Network for the Containment Performance Class and Working Width Class stated below.
The Transition shall comply with the manufacturer's Specification, component descriptions and Installation procedures. Further information on Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.
Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.
Installers shall have successfully undertaken suitable training for the system to be installed.
Varioguard Transition (Transition between VarioGuard and safety barrier)
Open Box Beam (OBB) and Double Sided OBB (DSOBB) to Steel Step Barrier (SSB) transition
Single sided Flexbeam to Varioguard transition
Double sided Flexbeam to Varioguard transition
Transitions 49 January 2015
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
H2 Contact the promotor Contact the promotor Asset International (A Division of Hill and Smith)Springvale Avenue
BilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
N2 W6 A Brifen (A Division of Hill and Smith)Springvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.uk
Web: www.hill-smith.co.ukN2 Contact the promotor Contact the promotor Britpave Barrier Systems Ltd
Atrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: info@bbsbarriers.comWeb site: www.bbsbarriers.com
H2 Contact the promotor Contact the promotor Britpave Barrier Systems LtdAtrium Court
The RingBracknellBerkshireRG12 1BWTel. 01344 393300email: info@bbsbarriers.comWeb site: www.bbsbarriers.com
H2 W2 B Britpave Barrier Systems LtdAtrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: info@bbsbarriers.comWeb site: www.bbsbarriers.com
N2 Contact promoter Contact promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
Concrete Step Barrier type 5 to Steel Step Barrier transition (including Steel Step Corridor)
BRITRANS' Open Box Beam to Wire Rope Safety Fence Transition
Britpave Concrete Step Barrier to Open Box Beam Transition
Britpave Concrete Step Barrier to Britpave Steel Step Barrier Transition
DB80AS-E to single sided OBB transition
Delta Bloc EP-REP/CJO/EOS
Transitions 50 January 2015
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
N2 Contact promoter Contact promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N2 Contact promoter Contact promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N2 Contact promoter Contact promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W4 C DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W4 C DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W4 C DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
DB80 6m to single sided OBB transition
DB80E to double sided OBB transition
DB80 6m to double sided OBB
DELTA BLOC In Situ 90 Step to DB80E 6m K150 transition
DELTA BLOC In Situ 90 Step to DB80 6m K180 transition
DELTA BLOC In Situ 90 Step to DB90 Step 6m K220 transition
Use of this transition must be with the agreement of the Overseeing Organisation
(refer to TD19/06, Section 6.6).
Use of this transition must be with the agreement of the Overseeing Organisation
(refer to TD19/06, Section 6.6).
Use of this transition must be with the agreement of the Overseeing Organisation
(refer to TD19/06, Section 6.6).
Transitions 51 January 2015
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
H2 W4 C DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W1 C DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W1 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
DB SafeLink Transition (DB100S to DB90 Step)
DELTA BLOC Single row DB90 Step 6m K220 to double row DB80 AS-E 6m K180S (bifurcation)
DELTA BLOC Single row DB80E 6m K150S to double row DB80 AS-E 6m K180S (bifurcation)
EP80B-E to DB 80AS-E
EP80B-E to CSB profile
Use of this transition must be with the agreement of the Overseeing Organisation
(refer to TD19/06, Section 6.6).
Use of this transition must be with the agreement of the Overseeing Organisation
(refer to TD19/06, Section 6.6).
Transitions 52 January 2015
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
EP80B-E to rigid structures
Single row EP80B-E to double row DB80AS-E (bifurcation)
Single row EP80B-E to double row EP80B-E (bifurcation)
DB100S to EP80Ba transition
DB80-E to EP80Ba transition
Transitions 53 January 2015
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N2 Contact the promotor Contact the promotor DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N2 Contact promoter Contact promoter DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N2 Contact promoter Contact promoter DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
DELTA BLOC EP 80B/EP 80B-E to double sided OBB transition
DB80AS-E to rigid structures 500mm wide
EP80B-E to rigid structures over 1.0m wide
EP80B to double sided OBB
DELTA BLOC EP-REPDELTA BLOC EP-CJODELTA BLOC EP-EOS
DELTA BLOC EP 80B/EP 80B-E to single sided OBB transition
Transitions 54 January 2015
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.uk
Web site: www.deltabloc.co.ukH2 W2 B DELTA BLOC UK Ltd
Unit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
DELTA BLOC EP 80B/EP 80B-E to DELTA BLOC DB 80AS-E transition
DELTA BLOC EP 80B/EP 80B-E to DELTA BLOC DB 80AS-E transition
DELTA BLOC EP 80B/EP 80B-E to DELTA BLOC DB 80AS-E transition
EP 80B/EP 80B-E to rigid structure transition
DELTA BLOC EP 80B/EP 80B-E to CSB transition
DELTA BLOC EP 80B/EP 80B-E to CSB transition
Transitions 55 January 2015
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W2 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N2 Contact the promotor Contact the promotor Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
N2 Contact the promotor Contact the promotor Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
N2 Contact the promotor Contact the promotor Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
Single row DELTA BLOC EP 80B/EP 80B-E to double row DELTA BLOC EP 80B/EP 80B-E (bifurcation)
Single row DELTA BLOC EP 80B/EP 80B-E to double row DELTA BLOC DB 80AS-E (bifurcation)
Barrierguard Gate connection to GA/72 and GA/74
S.A.B Gate connection to GA/74
Barrierguard 800 connection to GA/72 and GA/74
Transitions 56 January 2015
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
N2 Contact the promotor Contact the promotor Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
N1 Contact the promotor Contact the promotor Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
N2 W2 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
N1 W2 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
N2 W2 Contact the promotor Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
Tranzflex 80 N2W2 FlexBeam to Varley and Gulliver N1W2 VGSN 800 vertical infill parapet Transition
Note: Only permitted for use on roads where a speed limit
of less than 50 mph is operative.
Tranzflex 110 N2 Flexbeam to N1 W1 VGSN 500 Parapet Transition
Tranzflex 115 N2W2 Flexbeam to Varley and Gulliver N2W2 VGSN 900 series parapet
Single Sided Xtension P4 terminal (X-Tension 110 Single Sided P4 Terminal) to Flexbeam Transition
Tranzflex 100 N2 Flexbeam to Single Sided H1/H2 Flexbeam Plus Transition
Note: Only permitted for use on roads where a speed limit
of less than 50 mph is operative.
Transitions 57 January 2015
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
N2 W2 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
N1 W2 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
N2 W2 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
N2 W2 Refer to Promotor Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
N2 W2 Refer to Promotor Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
Tranzflex 120 N2 Flexbeam to N2 W1 VGSN 1000 Parapet Transition
Tranzflex 130 N2 Flexbeam to N1 W2 VGAN 500 Parapet Transition
Tranzflex 140 N2 Flexbeam to N2 W2 VGAN 1000 Parapet Transition
Tranzflex 150 N2 Flexbeam to H2 W3 VGSH 2000 Parapet Transition
Tranzflex 155 N2W2 Flexbeam to Varley and Gulliver H2W1 VarleyGuard parapet transition
Note: Only permitted for use on roads where a speed limit
of less than 50 mph is operative.
Transitions 58 January 2015
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
N2 W2 Refer to Promotor Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
N2 W2 Refer to Promotor Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
N2 W3 B Hill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
N2 W4 B SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: enquiries@saferoaduk.co.uk
N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: enquiries@saferoaduk.co.uk
Tranzflex 160 N2 Flexbeam to H4a W3 V6Guard Parapet Transition
Tranzflex 170 N2 Flexbeam to Varley and Gulliver H4aW4 VGSN 4000 Parapet Transition
Tranzflex 200 N2 W4 Double sided FlexBeam to H2 W5 Double sided Bri-Flex Transition
Megaflex Transition (H2W1 MegaGuard parapet to N2W4 safety fence)
MegaFlex to BACO parapet transition
Transitions 59 January 2015
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: enquiries@saferoaduk.co.uk
N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: enquiries@saferoaduk.co.uk
N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: enquiries@saferoaduk.co.uk
N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: enquiries@saferoaduk.co.uk
N1 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: enquiries@saferoaduk.co.uk
MegaFlex to BD52/93 steel parapet transition
MegaFlex to 100 series parapet transition
MegaFlex to Alcan parapet transition
MegaFlex to Lindley parapet transition
MegaFlex to Phoenix N1 parapet transition Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50
mph is operative.
Transitions 60 January 2015
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: enquiries@saferoaduk.co.uk
N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: enquiries@saferoaduk.co.uk
N1 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: enquiries@saferoaduk.co.uk
N2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: enquiries@saferoaduk.co.uk
H2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: enquiries@saferoaduk.co.uk
MegaFlex to SN2 parapet transition
1.5m high MegaGuard to H4a Concrete Barrier connection
Note: Only permitted for use on roads where road works are being undertaken and a speed limit of less than 50
mph is operative.
MegaFlex to Phoenix N2 parapet transition
MegaFlex to Sicuro parapet transition
MegaFlex to SN1 parapet transition
Transitions 61 January 2015
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
H1 W4 Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: enquiries@saferoaduk.co.uk
H2 Contact the promotor Contact the promotor SafeRoad UK Ltd.Dragonby ValeEnterprise ParkMannaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119Fax. 01724 281478email: enquiries@saferoaduk.co.uk
N2 W3 B Tata Steel Construction ProductsLlanwern WorksNewportSouth WalesNP19 4QZTel. 01633 290011 email: cep.sales@tatasteel.com
N2 W3 B Tata Steel Tubes EuropePO Box 101Weldon RoadCorbyNorthantsNN17 5UATel. 01536 402121email:marketing@tatasteel.com
N2 W1 B Tata Steel Tubes EuropePO Box 101Weldon RoadCorbyNorthantsNN17 5UATel. 01536 402121email:marketing@tatasteel.com
N2 W2 B Tata Steel Tubes EuropePO Box 101Weldon RoadCorbyNorthantsNN17 5UATel. 01536 402121email:marketing@tatasteel.com
MegaGuard to concrete structure connection
H1W4 MegaRail to H1W4 DROBB safety fence transition
Vetex N2W2 Safety Fence to Protect 365 N2W3 or N2W4 Transition
Protect 365 N2 Safety Fence to Protect 365 N2 Parapet transition
Protect 365 N2 to H4a Steel Parapet Transition
Protect 365 H4a Parapet to Protect 365 N2 Parapet Transition
Transitions 62 January 2015
Transition Name Containment Level Working Width Class Impact Severity Level Name and Address of Promoter Comments
N2 W2 B Tata Steel Tubes EuropePO Box 101Weldon RoadCorbyNorthantsNN17 5UATel. 01536 402121email:marketing@tatasteel.com
H2 W5 B Technische Sichereits-Systeme (TSS) GmbHAlfred Schutte-Allee 10D-50679 CologneGermanyTel. +49 221 980601Fax. 49 221 9806490email: edouard.cuijpers@tss-koeln.de
N2 Contact the promotor Contact the promotor Varley and Gulliver LtdAlfred StreetSparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: darren@v-and-g.co.uk
N1 Contact the promotor Contact the promotor Varley and Gulliver Ltd
Alfred StreetSparkbrookBirminghamB12 8JRTel. (0121) 773 2441email: darren@v-and-g.co.uk
Connection Between VGSH 4000 and VGSN 1000 VRS systems
Connection Between VGSH 4000 and VGSN 800 VRS systems
END OF TRANSITION SECTION - RETURN TO CONTENTS
Vetex N2 Safety Fence to Protect 365 N2 Safety Fence Transition
Transitions detailed in the NPSBS (Revision 1) are deemed acceptable for use on the Highways Agency Trunk Road Network, without the need for a Departure from Standard submission, as
TSS Vario - Transition between German B-profile safety fence and TSS Softbaer concrete barrier
Transitions 63 January 2015
SAFETY BARRIER GATES
Safety Barrier Gate Name Containment Level
Working Width Class Impact Severity Level
Name and Address of Promoter Comments
H1 W5 B Asset International (A Division of Hill and Smith)Springvale AvenueBilstonWolverhamptonWV14 0QLTel. 01902 499402Fax. 01902 402104email: peter@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
H2 W7 B SafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
H2 For 2-3 elements: B Snoline spa, represented by:W4 Highway Care Ltd.
The HighlandsFor 4-25 elements: B Detling Hill
W6 Detling HillMaidstone Kent ME14 3HTTel. 01622 734215
H1 Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
The following Safety Barrier Gates have been successfully tested to meet the requirements of BS EN 1317- 1 and 2 and DD ENV 1317 - 4 and have been accepted for use on the Highways Agency Trunk Road Network for the Containment Performance Class and Working Width Class stated below.
The Safety Barrier Gates shall comply with the manufacturer's specification, component descriptions and Installation procedures. Further information on Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.
Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.
Installers shall have successfully undertaken suitable training for the system to be installed.
SOLOGUARD Emergency and Maintenance Crossing Point System
Gateguard Removal Barrier System
S-A-B Class H2 Gate (For emergency and maintenance cross over points)
Safety Barrier Gates 64 January 2015
Safety Barrier Gate Name Containment Level
Working Width Class Severity Level Name and Address of Promoter Comments
H2 W2 Refer to Promoter Asset International (A Division of Hill and Smith)Springvale AvenueBilston
WolverhamptonWV14 0QLTel. 01902 499402
Fax. 01902 402104email: peter@hill-smith.co.ukWeb Site: www.asset-vrs.co.uk
H2 W2 Refer to Promoter Britpave Barrier Systems LtdAtrium CourtThe RingBracknellBerkshireRG12 1BWTel. 01344 393300email: bbsinfo@britpave.org.ukWeb site: www.britpavebarriersystems.com
H2 W6 B DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
H2 W5 A DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
The following Safety Barrier Gates have the same profile and performance characteristics of their compliant BS EN 1317 safety barriers which are deemed acceptable for use on the Highways Agency Trunk Road Network for the Containment Performance Class and Working Width Class stated below.
The Safety Barrier Gates shall comply with the manufacturer's specification, component descriptions and Installation procedures. Further information on Impact Severity Levels for the product and copies of documents and drawings can be obtained from the Promoter.
Steel Step Corridor System ( For Emergency and Maintenance Crossing Points)
Steel Step Barrier Gate (For Emergency Crossing Points)
DB SafeGate DB80 6m K180
DB SafeGate DB100S 6m K220
Safety Barrier Gates 65 January 2015
Safety Barrier Gate Name Containment Level
Working Width Class Severity Level Name and Address of Promoter Comments
H2 W6 C DELTA BLOC UK LtdUnit A Fox WayTrinity Business ParkWaldorf WayWakefield, WF2 8EETel. 0845 30 40 705Fax. 0845 30 40 706email: tony.walker@deltabloc.co.ukWeb site: www.deltabloc.co.uk
N2 W5 Refer to Promoter Highway Care Ltd.The Highlands
H2 W8 Refer to Promoter Detling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
H2 W2 Refer to Promoter SafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
END OF SAFETY BARRIER GATE SECTION - RETURN TO CONTENTS
SafeRoad Steel Step Barrier Gate
Barrierguard 800 Gate (For Emergency and Maintenance Crossing Points), including connection to corrugated W-beam safety fencing
The installation of safety barriers with an ASI Class of C must be with the
agreement of the Overseeing Organisation (refer to TD19/06,
Sections 3.6 and 3.7).
DB SafeGate DB90 Step 6m K220
Safety Barrier Gates 66 January 2015
MISCELLANEOUS
Product Impact Severity Level Name and Address of Promoter Comments
A Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.ukHill and SmithSpringvale Business and Industrial ParkBilstonWolverhamptonWest MidlandsWV14 0QLTel: 01902 499400Fax: 01902 499419Email: technical@hill-smith.co.ukWeb: www.hill-smith.co.uk
A SafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth Lincolnshire
H1 DN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
As per the host safety barrier
The following products have been accepted for use on the Highways Agency Road Network and are for use in conjunction with vehicle restraint systems.
Essential characteristic information only is provided and confirmation is required that the system selected complies fully with all HA contractual conditions and requirements as detailed in the DMRB, MCHW, and any contract specific or site specific documentation.
BikeGuard (Motorcyclist Protection System fitted to safety barriers)
BikeGuard may be fitted to any UK system listed in the Non-Proprietary Safety Barrier Systems (NPSBS). It may also be fitted to any other system in the Highways Agency Approved Road Restraint
System List providing that Highway Care Limited first obtains the approval of the Promoter/Manufacturer of the safety barrier system
BikeGuard is to be attached to.
FlexGuard (Motorcyclist Protection System fitted to safety barriers)
MegaRail es with a motorcyclist protection device
Motorcyclist Protection System fitted to TCB, OBB, FlexBeam/FlexBeam Plus (both single and double sided versions of
these systems), the Hill and Smith H1/H2 safety barrier, and the Briflex vehicle restraint system.
N2W2, CE marked system
Miscellaneous 67 January 2015
Product Impact Severity Level Name and Address of Promoter Comments
A SafeRoad UK Ltd.Dragonby ValeEnterprise ParkManaberg WayScunthorpeNorth LincolnshireDN15 8XFTel. 01724 289119email: enquiries@saferoaduk.co.uk
N2W2, CE marked system
END OF MISCELLANEOUS SECTION - RETURN TO CONTENTS
ESP 4.0 UFS Bikeguard
Miscellaneous 68 January 2015
TRCUK MOUNTED ATTENUATORS (LORRY MOUNTED CRASH CUSHIONS)
TMA/LMCC Name Name and Address of Promoter CommentsAcklea Ltd.Unit 1Clark AvenuePorte Marsh Industrial EstateClaneWiltshireSN11 9RDTel. 01249 822 600Fax. 01249 820 111email: andy.dougan@acklea.bizKing Highway Products Ltd.RiversideMarket HarboroughLeicestershireLE16 7PXTel. 08707 475969Fax. 08707 475970email: sales@kinghighway.co.uk
The following Truck Mounted Atennuators (TMAs) [also known as Lorry Mounted Crash Cushions (LMCCs)] meet the requirements of TD 49/07 and hence, have demonstrated compliance with a 1500kg car impact at the speed of
the performance class. They may be used on the Highway Agency Trunk Road Network provided that a special dispensation order known as a Vehicle Special Order (VSO) is obtained from the Department for Transport.
In addition a Vehicle Inspectorate Form VTG 10 will need to be filed if the TMA is fitted with an auto impact brake system.
The TMA shall comply with the manufacturer's Specification, component descriptions and Installation procedures. Copies of documents and drawings can be obtained from the Promoter.
Scorpion Lorry Mounted Crash Cushion
MPS-350 Lorry Mounted Crash Cushion For use on roads with a speed limit of 70mph or less
For use on roads with a speed limit of 70mph or less
Lorry Mounted Crash Cushions 69 January 2015
TMA/LMCC Name Name and Address of Promoter CommentsKing Highway Products Ltd.RiversideMarket HarboroughLeicestershireLE16 7PXTel. 08707 475969Fax. 08707 475970email: sales@kinghighway.co.ukKing Highway Products Ltd.H1Market HarboroughLeicestershireLE16 7PXTel. 08707 475969Fax. 08707 475970email: sales@kinghighway.co.ukTrinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HS Fax: 01473 221106Email: europe.sales@trin.netWebsite: www.energyabsorption.comTrinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: europe.sales@trin.netWebsite: www.energyabsorption.com
Vorteq™ Trailer
SafeStop Lorry Mounted Crash Cushion
MPS-350 Lorry Mounted Crash Cushion
For use on roads with a speed limit of 70mph or less
For use on roads with a speed limit of 70mph or less
For use on roads with a speed limit of 70mph or less
For use on roads with a speed limit of 70mph or less
Vorteq™ Trailer
Lorry Mounted Crash Cushions 70 January 2015
TMA/LMCC Name Name and Address of Promoter CommentsTrinity Highway Products InternationalCrown House, Crown StreetIpswichIP1 3HSTel: 01473 221105Fax: 01473 221106Email: europe.sales@trin.netWebsite: www.energyabsorption.comVerdegroDistributed in the UK by:Highway Care Ltd.The HighlandsDetling HillDetling MaidstoneKentME14 3HTTel. 01622 734215Fax. 01622 735106email: info@highwaycare.co.ukWeb site: www.highwaycare.co.uk
END OF TMA/LMCC SECTION - RETURN TO CONTENTS
IP70 For use on roads with a speed limit of 70mph or less
For use on roads with a speed limit of 70mph or less
SafeStop Lorry Mounted Crash Cushion
Lorry Mounted Crash Cushions 71 January 2015
Recommended