View
282
Download
1
Category
Preview:
Citation preview
8/10/2019 Safety Relay Catalogue Products
1/18
S a
f e t y r e
l a y s
Safety relaysSafety relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466
Programmable safety relays . . . . . . . . . . . . . . . . . . . . 473
Safety software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480
www.lcautomation.com
8/10/2019 Safety Relay Catalogue Products
2/18
Safety relays www.lcautomation.com
Blackburn Office - 01254 685900 Chippenham Office - 01249 460099466
20% reduction in wiring.Contact expansion viaconnectors
Rapidinstallations innovativespring-loaded
terminals,chambersoperatedindividually
Maximum flexibility.Operating modes and
timer functions areselectable
Diagnostics inseconds via 6LEDs no
externalmeasuringdevicesrequired
Simpleconfiguration,
designationand positionof the
terminals is the same onall unit types
Rapid assembly
via spring clips,no need for tools
Safe from manipulation,setting elements have alockable cover
Pilz multi functional PNOZsigma range of compact safety relays are easy toinstall and expand with improved switching capacity from as little as12.5mm wide.Ideal for machine builders and panelbuilders, these fourth generationsafety relays incorporate a number of features and internationalapprovals (important for export).
They also offer significant costsavings because less units nowcover a wider range of applications,reducing your stock holding.
A combination of jumper connectedexpansion modules and spring loadedcage clamp terminals can also reduceyour wiring time by up to 20%.To increase the number of safetyoutputs use the PNOZsigmaexpander modules see page 468.
The safety relays provide diagnosticsin seconds using the LED indicationpanel, displaying:
Power Input status
Switch statusResetFault
PNOZsigma safety relays range overview
Key features and benefits of thePNOZsigma range
8/10/2019 Safety Relay Catalogue Products
3/18
Safety relays www.lcautomation.com
467Blackburn Office - 01254 685900 Chippenham Office - 01249 460099
Technical specification
PNOZs1 PNOZs2 PNOZs3 PNOZs4 PNOZs5 PNOZs6Input channels 1 1 1 and 2 2 2 2
Safety outputs 2 NO 3 NO 2 NO 3 NO 2 NO 3 NOSafety outputs (timed) 2 NO
Time delay range 0-300 seconds
Auxiliary outputs 1 NC 1 NC 1 NCSemi conductor outputs 1 1 1 1 1 1Input options:
Emergency stop
Safety gate switch
Light curtain
Two-hand control Reset Manual Manual/monitored Monitored Manual/automatic Manual/automatic Manual
Start Automatic Automatic Start-up test Start-up test Start-up test Supply voltage 24V d.c. 24V d.c. 24V d.c. 24V d.c. 24V d.c. 24V d.c.
Universal power supply 48-240V a.c./d.c. 48-240V a.c./d.c. External fast fuse rating 4A 4A 4A 6/10A 6A 6A
Connections Plug-in Plug-in Plug-in Plug-in Plug-in Plug-in
Housing width (mm) 12.5 17.5 17.5 22.5 22.5 22.5
PFHD 2 x 10-7 2.5 x 10 -9 2.31 x 10 -9 2.31 x 10 -9 2.31 x 10 -9 2.62 x 10 -9
PFHD (delayed) 2.14 x 10 -9 Safety category Cat 2 Cat 2 Cat 4 Cat 4 Cat 4 EN574, Typ IIICPerformance Level PLd PLd PLe PLe PLe PLeSIL claim SIL CL2 SIL CL3 SIL CL3 SIL CL3 SIL CL3 SIL CL3
Can be connected
PNOZs1PNOZs2PNOZs3PNOZs4
PNOZs4, universal voltage
PNOZs5
PNOZs5, universal voltagePNOZs6
Description
750101 PNOZS124VDC 93.47750102 PNOZS224VDC 110.48750103 PNOZS324VDC 114.73750104 PNOZS424VDC 148.73
750134 PNOZS4/48-240VAC/DC 157.22
750105 PNOZS524VDC 216.72
750135 PNOZS5/48-240VAC/DC 222.51750106 PNOZS624VDC 250.71
Screw terminals
ListIdent No Order Code Price
751101 PNOZS1C24VDC 93.47751102 PNOZS2C24VDC 110.48751103 PNOZS3C24VDC 114.73751104 PNOZS4C24VDC 148.73
751105 PNOZS5C24VDC 216.72
751106 PNOZS6C24VDC 250.71
Spring-loaded terminals
ListIdent No Order Code Price
PNOZsigma safety relays
To increase the number of safety outputs use PNOZsigma expander modules, see next page
s1 s4 s5 s6s2 s3
8/10/2019 Safety Relay Catalogue Products
4/18
Safety relays www.lcautomation.com
Blackburn Office - 01254 685900 Chippenham Office - 01249 460099468
PNOZsigma contact expander modulesTechnical specification
PNOZs7 PNOZs7.1 PNOZs7.2 PNOZs8 PNOZs9 PNOZs10 PNOZs11 PNOZs22Safety outputs 4 NO 3 NO 4 NO 2 NO 3 NO 4 NO 8 NO 2 x 3 NOSafety outputs (timed) Time delay range 0-300 seconds
Auxiliary outputs 1 NC 1 NC 1 NC 1 NC 1 NC 2 NCSemi conductor outputs 1 1 1 1 Compatible relays:
PNOZelog
PNOZmulti
PNOZsigma
PNOZmm0.1p
PNOZmm0.2p
PNOZ X
Supply voltage 24V d.c. 24V d.c. 24V d.c. 24V d.c. 24V d.c. 24V d.c. 24V d.c. 24V d.c.External fast fuse rating 6A 6A 6A 4A 6A 10A 10A 6A Connections Plug-in Plug-in Plug-in Plug-in Plug-in Plug-in Plug-in Plug-inHousing width (mm) 17.5 17.5 17.5 12.5 17.5 45 45 22.5
PFHD 2.31 x 10 -9 2.31 x 10 -9 2.31 x 10 -9 2 x 10-7 2.34 x 10 -9 2.31 x 10 -9 2.31 x 10 -9 2.31 x 10 -9
Safety category* Cat 4 Cat 4 Cat 4 Cat 2 Cat 4 Cat 4 Cat 4 Cat 4Performance Level* PLe PLe PLe PLd PLe PLe PLe PLeSIL claim* SIL CL3 SIL CL3 SIL CL3 SIL CL2 SIL CL3 SIL CL3 SIL CL3 SIL CL3
*The category that can be achieved depends on the category of the base unit. The contact expander module may not exceed this.
s7 s8 s9 s10 s11 s22
PNOZsigmacontact expander modules areused to increase
the number of contacts availableon a base unit'sinstantaneoussafety contacts.
PNOZs7PNOZs7.1PNOZs7.2PNOZs8PNOZs9PNOZs10PNOZs11PNOZs22
Description
750107 PNOZS724VDC 97.73750167 PNOZS7124VDC 93.47750177 PNOZS7224VDC 102.78750108 PNOZS824VDC 84.99750109 PNOZS924VDC 131.73750110 PNOZS1024VDC 161.47750111 PNOZS1124VDC 161.47750132 PNOZS2224VDC 157.52
Screw terminals
ListIdent No Order Code Price
751107 PNOZS7C24VDC 97.73751167 PNOZS71C24VDC 93.48751177 PNOZS72C24VDC 101.97751108 PNOZS8C24VDC 84.99751109 PNOZS9C24VDC 131.73751110 PNOZS10C24VDC 161.47751111 PNOZS11C24VDC 161.47751132 PNOZS22C24VDC 163.50
Spring-loaded terminals
ListIdent No Order Code Price
8/10/2019 Safety Relay Catalogue Products
5/18
Safety relays www.lcautomation.com
469Blackburn Office - 01254 685900 Chippenham Office - 01249 460099
PNOZs30 with screw terminals 750330 PNOZS3024VDC 628.32PNOZs30C with spring loaded terminals 751330 PNOZS30C24VDC 628.32
PNOZs30 Safe speed monitorFeatures
Provides safe monitoring of standstill,rotational speed, position, speedrange, direction of rotation, andbroken shearpinFeedback from incremental encoder (to RJ45)Feedback from proximity sensors(terminals)
Advance warning of shutdown when threshold is reachedProductivity is increased byavoiding unnecessary completeshutdown of processesParameters are quickly entered by push & turn rotary knob, and storedon chipcardExpansion interface for 2 moreexpansion unitsDisplays current frequency, currentposition, warning & error messages
FeaturesMonitors back EMF from single or
three phase motorsNo external inputs other thanconnection to the motor windings arerequiredSingle or dual channel monitoring2 safety outputs are enabled when
the back EMF falls below the threshold level
Detects open circuits
Technical specificationSupply voltage . . . . . . .24V-240V a.c./d.c.Inputs . . . . . . . . . . . . . . . . . . . .1 channelSafe outputs . . . . . . . . . . . . . . . . . 2 NO
Auxiliary outputs . . . . . . . . . . . . . . 2 NCExternal fast fuse rating . . . . . . . . . . .6A Connections . . . . . . . . . . . . . . . . .Plug in
(either spring-loaded or screw terminal)Housing width . . . . . . . . . . . . . . . .45mm
Technical specificationSupply voltage . . . . . . 24V-240V a.c./d.c.Inputs . . L1, L2, L3 from monitored motor Switch threshold . . . . . 0-0.5V or 0-0.3V Sensitivity adjustment . . . . . . Via front dialSafety contacts . . . . . . . . . . . . 2 N/O, 4A
Auxiliary contacts . . . . . . . . . . . . . 1 N/C2 x semiconductor
LED indication . . . . . . . . . Power, output, fault & channels
Connection . . . . . Screw or spring loaded
ListDescription Ident No Order Code Price
PSWZX1PC, 0.5V with spring loaded terminals 787949 PSWZX1PC05V 381.95PSWZX1P, 0.5V with screw terminals 777949 PSWZX1P05V 344.85PSWZX1PC, 0.3V with spring loaded terminals 787950 PSWZX1PC03V 337.72PSWZX1P, 0.3V with screw terminals 777950 PSWZX1P03V 344.85
ListDescription Ident No Order Code Price
1 input monitoring
Cat 2EN 954-1 Category3.28 x 10-8PFHD
PLdEN ISO 13849-1 Performance LevelSIL CL 2EN 62061 SIL Claim
2 input monitoring
Cat 3EN 954-1 Category1.50 x 10-8PFHD
PLeEN ISO 13849-1 Performance LevelSIL CL 3EN 62061 SIL Claim
Cat 4EN 954-1 CategoryPLeEN ISO 13849-1 Performance Level
SIL CL 3EN 62061 SIL Claim
PSWZX1P Standstill detection safety relay
The device uses two separatemeasuring channels to measure theregenerated voltage, induced from
the motor during the rundownperiod or during start-up.If the voltage falls below the setresponse value (standstill threshold),
the standstill monitor enables themonitored plant. If the voltageexceeds the set release value, the
standstill monitor disables themonitored plant. To reactivate, the voltage at both channels must fallbelow the response value U on within
the time t g.
NEW
8/10/2019 Safety Relay Catalogue Products
6/18
Safety relays www.lcautomation.com
Blackburn Office - 01254 685900 Chippenham Office - 01249 460099470
Safety relay with 1 time delay output SRB-211ST-V.2-24VAC/DC 296.36Safety relay with 2 time delay outputs SRB-324-ST-V.2-24VAC/DC 303.27
Safety relays with time delay outputs
This range of safety relays have theaddition of either one or two timedelay contacts which are adjustablefrom 1 to 30 seconds. The relaysare used for applications where astop request is initiated to allow arun down of a rotating hazardbefore a second stop request halts
the machine.
Technical specificationSupply voltage . . . . . . . . . . . 24V d.c./a.c.Outputs
SRB211ST . . . 2 safety contacts 250V a.c. 8A 1 auxiliary contact 250V a.c. 6A
SRB324ST . . . 3 safety contacts 250V a.c. 8A 2 auxiliary contacts 250V a.c. 6A
Signal output . . . . . . . 1 24V d.c. 100mA Connection type . . . . . . . Screw terminalMounting . . . . . . . . . . . . . . . . . . DIN railDimensions
SRB211ST . . . h100 x w22.5 x d121mm
SRB324ST . . . . h100 x w45 x d121mmPFH value
STOP 0 . . . . . . . . . . . . . 2.00 x 10 -8 /hSTOP 1 . . . . . . . . . . . . . 2.00 x 10 -7 /h
ListDescription Order Code Price
FeaturesFor use with emergency stops,solenoid interlocks, safety switchesand light curtains1 or 2 channel controlInstantaneous safety contacts (STOP 0)Time delay safety contacts (STOP 1)1 transistor signalling outputLED status indicationPlug-in screw terminalsEDM external device monitoringMonitored inputs
2 NC contacts Wire breakage detectionEarth connection detection
Safety relay with manual trailing edge reset S RB301-MA-24VAC/DC 129.27Safety relay with automat ic reset SRB301-MC-24VAC /DC 144.61Safety relay with eith er manual trailing edge or SRB301-ST-V.2-24VAC/DC 205.95automatic reset
Universal safety relays
Universal safety relays that can beused in a wide range of applications. They are ideal for
holding as spares and can be used with any type of safety device witheither manual or automatic reset.
FeaturesFor use with emergency stops,position switches, solenoid interlocks,magnetic safety switches and
light curtainsInstantaneous safety contacts (STOP 0)1 signalling output (SRB301-ST-V.2)LED status indication1 or 2 channel monitoringShort circuit protectedEDM external device monitoring
ListDescription Order Code Price
Technical specificationSupply voltage . . . . . . . . . . . 24V d.c./a.c.Outputs . . 3 safety contacts 250V a.c. 8A
1 auxilliary contact 24V d.c. 2A
Signalling output . . . . 1, 24V d.c. 100mA (SRB301-ST-V.2)Connection type . . . . . . . Screw terminalMounting . . . . . . . . . . . . . . . . . . DIN railDimensions
SRB301-MA . . . . h100 x w22.5 x d121mmSRB301-MC . . . . h100 x w22.5 x d121mmSRB301-ST-V.2 . . h120 x w22.5 x d121mm
Cat 4EN 954-1 CategoryPLeEN ISO 13849-1 Performance Level
SIL CL 3EN 62061 SIL Claim20 yearsMission Time
Cat 4EN 954-1 CategoryPLeEN ISO 13849-1 Performance Level
SIL CL 3EN 62061 SIL Claim20 yearsMission Time
Cat 3EN 954-1 CategoryPLdEN ISO 13849-1 Performance Level
SIL CL 2EN 62061 SIL Claim20 yearsMission Time
STOP 0 STOP 1
8/10/2019 Safety Relay Catalogue Products
7/18
Safety relays www.lcautomation.com
471Blackburn Office - 01254 685900 Chippenham Office - 01249 460099
Two hand control relay SRB201-ZH-24VDC 210.43
Two hand control relay
Designed to be used with two handcontrol stations.
Inputs for each channel must be aNO/NC and the monitor ensures
they are made within the required time scale. If the sequence is notcorrect, start up will be prevented.
ListDescription Order Code Price
Technical specificationSupply voltage . . . . . . . . . . . . . . 24V d.c.Monitored inputs
2 NC/2NO contacts
Short circuit recognition Wire breakage detectionEarth connection detection
Outputs . . 2 safety contacts 250V a.c. 6A 1 auxiliary contact 24V d.c. 2A
Connection type . . . . . . . Screw terminalMounting . . . . . . . . . . . . . . . . . . DIN railDimensions . . . h100 x w22.5 x d121mmPFH value . . . . . . . . . . . 2.00 x 10 -8 /h
FeaturesMonitoring two-hand control panels
to EN 574 III CInstantaneous safety contacts (STOP 0)
1 auxiliary NC contact withantivalent functioning principle(auxiliary contacts are not to be usedin safety circuits)Feedback circuitElectronic protectionLED status indicationPlug-in screw terminalsEDM external device monitoring
Safety relay SRB301-AN-V.2-24VAC/DC 213.81
Safety relay for 1 NO/1 NC safety switches
SRB310AN is an antivalent safety relay for monitoring 1 NO/1 NCinput devices such as BNS magneticswitches. It ensures the switch haschanged state and can also preventsingle channel faults in someapplications. The relay monitors achange of contact status from NC
to NO in one channel and vice versa in the second channel.
Technical specificationSupply voltage . . . . . . . . . . . 24V d.c./a.c.Monitored inputs . . . . . . . . . 1 NC/1NO
contacts, short circuit, wire breakage and earth connection
Outputs . . 3 safety contacts 250V a.c. 6A 1 auxiliary contact 24V d.c. 2A
Connection type . . . . . . . Screw terminalMounting . . . . . . . . . . . . . . . . . . DIN railDimensions . . . h100 x w22.5 x d121mmPFH value . . . . . . . . . . . 2.00 x 10 -8 /h
ListDescription Order Code Price
FeaturesMonitoring of range magnetic safety sensorsInstantaneous safety contacts (STOP 0)1 signalling outputShort circuit recognition
Additional contacts using an inputexpander module (see page 472)LED status indicationEDM external device monitoring
Cat 4EN 954-1 CategoryPLeEN ISO 13849-1 Performance Level
SIL CL 3EN 62061 SIL Claim20 yearsMission Time
Cat 4EN 954-1 Category PLeEN ISO 13849-1 Performance LevelSIL CL 3EN 62061 SIL Claim20 yearsMission Time
8/10/2019 Safety Relay Catalogue Products
8/18
Safety relays www.lcautomation.com
Blackburn Office - 01254 685900 Chippenham Office - 01249 460099472
FeaturesConnect up to 4 switches per interface, e.g. BNS safety magneticswitches, emergency stop controldevices, interlocking devices and
AOPDsConnection of switches with 2 NCcontacts (PROTECT-PE-02) or of switches with NC/NO contacts(PROTECT-PE-11)Crosswire monitoring of the inputcircuits (only PROTECT-PE-02)Signalling output for each switchCascading possible for the connectionof up to 80 switches6 LED to show operating conditions
Features
For signal processing of potential freeoutputs, e.g. command devices2 channel control1 safety contact, STOP 0Time adjustable from 3s to 30sSignal processing with trailing edge4 LEDs to show operating conditions Safety relay with double reset SRB100DR-24VAC/DC 141.73
Safety relay w ith double reset
SRB100DR is a special time relay with a double reset used for the safepassage of machine operators in
robot cells where it can be possible to restart a machine without theperson in the cell being spotted.By using a pushbutton in the cell theoperator must make sure the cell isclear before a restart is made. Once
the first pushbutton is activated, theoperator must activate the secondreset button within a set time, toensure a start is made. If the time
frame is exceeded the sequence muststart again.
Technical specificationSupply voltage . . . . . . . . . . . 24V d.c./a.c.Monitored inputs . . . . . . 2 NC contacts,
short circuit, wire breakageand earth connection
Output . . . . 1 safety contact 250V a.c. 6A Connection type . . . . . . . Screw terminalMounting . . . . . . . . . . . . . . . . . . DIN railDimensions . . . h100 x w22.5 x d121mm
ListDescription Order Code Price
4 x 2 channel inputs, 2 NC or OSSD input devices PROTECT-PE-02-SK 87.554 x 2 channel inputs, 1 NO/1 NC input devices such PROTECT-PE-11-SK 67.01as magnetic switches
Protect PE Input expander modules
Protect PE expander modules allowup to 4 additional inputs to beconnected to a safety relay.The input units are suitable for either 2 NC inputs or 1 NC/1 NO input
types. All units have a non safetyoutput to allow the status of the input
to be fed back to a PLC or other control system.Each individual input is monitored for short circuits & open circuit detection.
Technical specificationSupply voltage . . . . . . . . . . . . . . 24V d.c.Monitored inputs . . . . . . . . 4 x 2 channel
see order code for configurationshort circuit, wire breakage and
earth connectionOutputs . . 2 auxiliary contact 24V d.c. 2A
7 signalling outputs 24V d.c. 100mA Connection type . . . . . . . Screw terminalMounting . . . . . . . . . . . . . . . . . . DIN rail
Dimensions . . . . . h126 x w48 x d43mm
ListDescription Order Code Price
Cat 4EN 954-1 CategoryPLeEN ISO 13849-1 Performance Level
SIL CL 3EN 62061 SIL Claim20 yearsMission Time
Cat 3EN 954-1 CategoryPLdEN ISO 13849-1 Performance Level
SIL CL 2EN 62061 SIL Claim20 yearsMission Time
8/10/2019 Safety Relay Catalogue Products
9/18
Safety relays www.lcautomation.com
473Blackburn Office - 01254 685900 Chippenham Office - 01249 460099
FX3-CPU0 Flexi Soft controller 1043783 132.44FX3-CPU1 Flexi Soft controller with 2 EFI connections 1043784 187.98FX3-MPL0 Flexi Soft memory plug 1043700 21.13FX3-MPL1 Flexi Soft memory plug for ProfiNet 1047162 28.82FX3-XTDI Flexi Soft 8 input module 1044124 141.82FX3-XTIO Flexi Soft 8 input/4 output module 1044125 205.07FX0-GCAN Flexi Soft CANOpen Gateway 1044076 295.80FX0-GENT Flexi Soft Ethernet/IP Gateway 1044072 311.85FX0-GETC Flexi Soft EtherCAT Gateway 1051432 311.85FX0-GMOD Flexi Soft Modbus TCP Gateway 1044073 311.85FX0-GPNT Flexi Soft ProfiNet IO Gateway 1044074 311.85FX0-GPRO Flexi Soft ProfiBus-DP Gateway 1044075 311.85
Flexi Soft safety control system
Technical specificationNumber of inputs . . . . . . . . . . . . . 0-96,
depending on module combinationNumber of outputs . . . . . . . . . . . . 0-48,
depending on module combinationNumber of EFI interfaces . . . . . . . . . . 2Configuration interface . . . . . . . . RS232Logical functions . . . . . AND, OR, NOT,
XNOR, XOR Safety functions . . . . . . . Emergency stop
function, machine control(e.g. PSDI), differentiation
between man and material(muting), control modes
and operating mode selectionConnection type . . . . . . . M12 8-pin plugDimensions . h93.7 x w22.5 x d120.8mmOperating temperature . . . . 0 to +50C
Flexi Soft is a programmable andexpandable safety control systemcapable of being integrated into
various networks.The main FX3-CPU system modulemonitors and processes all inputsignals via the safety logic stored in
the memory plug. These signals thenswitch outputs on the system
through the FLEX BUS+ interface which connects all the units together.The main unit has an RS232 interface
which can be used to upload or
change the Flexi Soft system settings.It can also be used for permanentdiagnosis, using a PLC or HMI for example.
The FX3-CPU1 version of the mainmodule also has 2 EFI-connections.The EFI interface (enhancedfunction interface) is a two wirecommunication between the safety sensor and controller. All EFIsensors can be connected toFlexi Soft, be accessed and
programmed via the Flexi Soft
sRS232 connection.The input/output extension moduleFX3-XTIO has 8 safety inputs and4 safety outputs.The input expansion moduleFX3-XTDI has 8 safety inputs.
ListDescription Order Code Price
FeaturesCompact, 22.5 mm widthRS232 connection for configurationand real-time diagnosticsSystem plug stores the configurationof the safety controller
Available with EFI interfaceSafety networking of up to fourFlexi Soft stationsUp to 12 input or input/outputexpansion modules can beconnected in one systemExpandable with up to two gatewaysper system rack
BenefitsLess downtime due to gateways,e.g., ProfiNet I/O, ProfiBus-DP,EtherCAT, CANopen, Modbus TCPand Ethernet (TCP/IP)Safe communication withoutadditional hardware reduces costsand saves timeRS232 connection is standard withall main modules, enabling real timediagnostics for fast commissioning,faster troubleshooting andreduced downtime
FX3-CPU Comms module Input module Output module
PLeEN ISO 13849-1 Performance LevelSIL CL 3EN 62061 SIL Claim
8/10/2019 Safety Relay Catalogue Products
10/18
Safety relays www.lcautomation.com
Blackburn Office - 01254 685900 Chippenham Office - 01249 460099474
PNOZmulti MiniFeatures
Configurable inputs and outputs usingPNOZmulti Configurator software,
via chip card or mini USB interface
Compact design, only 45mm wideIntegrated display and customisable
textSave up to 40% time and cost inengineering phasesLess wiring saves control panel spaceNon-expandable version is suitablefor 3-6 safety functionsExpandable safety functions is idealfor 4 or more safety functions or
where distributed control is required
Expandable units can connect up tofour Safe link modules, one EthernetTCP/IP module and one serial module- to the left, and PNOZSigmaexpander modules - to the rightSafe link modules connect any combination of PNOZmulti andPNOZmulti Mini to createnetworked, distributed safe controlUsing safe link modules for PDP67 F8DI ION decentralised input/outputsmodules, a maximum of 64 dualchannel remote outputs can beconnected (using 4 Safe link modules)
Simple overview;via 6 LEDs no external measuringdevices required
Rapid assemblyvia spring clips;no need for tools
Rapid installation;spring-loadedterminals, chambersoperated individually(with optional screwterminals)
Simple diagnostics;integrated display forshowing informationand diagnostcs
Simple configurationwith the PNOZmulti
Configurator via astandard USB interface
Values are easy torequest thanks to a rotary
knob with key function(push and turn)
Safe frommanipulation;
setting elements havea lockable cover andpassword protection
Cat 4EN 954-1 CategoryPLeEN ISO 13849-1 Performance Level
SIL CL 3EN 62061 SIL Claim
Non-expandable multi Mini 772000 PNOZmm0p 392.70Expandable multi Mini 772001 PNOZmm0.1p 417.13Expandable multi Mini; built in Safe link 772002 PNOZmm0.2p 503.59Safe link module 772020 PNOZmml1p 182.96Safe link module for PDP67 F 8DI ION 772021 PNOZmml2p 180.84Ethernet module 772030 PNOZmmc1p 152.46Serial comms module 772031 PNOZmmc2p 86.77
750008 19.04750008 19.04750008 19.04750004 14.27750004 14.27750004 14.27750004 14.27
751008 19.04751008 19.04751008 19.04751004 14.27751004 14.27751004 14.27751004 14.27
List List ListDescription Ident No Order Code Price Order Code Price Order Code Price
Screw terminals Spring-loaded terminals
Technical specificationHousing width . . . . . . . . . . . . . . . 45mmSupply voltage . . . . . . . . . . . . . . 24V d.c.Safe outputs . . . . . . . . . . . . . 4 solid stateSafe inputs . . . . . . . . . . 20 single channel
(can also be configured as standard[non-safe] inputs)
Test pulses . . . . . . . . . . . . . . . . . . . . . . 4Connections . . . . . . . . . . . . . . . . . Plug in
8/10/2019 Safety Relay Catalogue Products
11/18
Safety relays www.lcautomation.com
475Blackburn Office - 01254 685900 Chippenham Office - 01249 460099
Non-expandable PNOZ Multi 773110 PNOZm0p 420.09Expandable PNOZ Multi 773100 PNOZm1p 636.50Expandable PNOZ Multi; with Ethernet TCP/IP 773103 PNOZm1pETH 881.93Expandable PNOZ Multi; for press applications 773120 PNOZm2p 755.31Expandable PNOZ Multi; for burner management 773125 PNOZm3p 874.381 set spring loaded terminals 783100 15.28
1 set plug in screw terminals 793100 15.28Bus terminator 779110 6.12
PNOZmulti base units
The configurable control systemPNOZmulti is multifunctional,freely configurable and tailormadefor use in many different areas of mechanical engineering.
As your plant expands, the modular PNOZmulti simply expands with it,adding up to eight expansionmodules in any combination to suityour specific requirements: Input and output modules Fieldbus modules Safe speed and standstill monitorsSafe link modules for safely
connecting several base units
Safe analogue modules for safelyconnecting decentralised periphery
Flexible application with modular expandabilityUp to 90 I/Os (basic- plus
expansion modules)Up to 8 incremental encodersUp to 8 safety analogue inputsUp to 4 PNOZmulti to PNOZmulti
safety connectionsUp to 16 decentralised
PDP67-modules64 dual channel decentralised inputs1 fieldbus-module
FeaturesConfigurable inputs and outputs usingPNOZmulti Configurator software,
via chip card or mini USB interface
Save up to 40% time and cost inengineering phasesLess wiring saves control cabinetspace
Technical specificationHousing width . . . . . . . . . . . . . . 135mmSupply voltage . . . . . . . . . . . . . . 24V d.c.Safe outputs . . . . . . . . . . . . . 4 solid state
+ 2 relay (2 contacts)Safe inputs . . . . . . . . . . 20 single channelTest pulses . . . . . . . . . . . . . . . . . . . . . . 4
Connections . . . . . . . . . . . . . . . . . Plug in
ListDescription Ident No Order Code Price
Cat 4EN 954-1 CategoryPLeEN ISO 13849-1 Performance Level
SIL CL 3EN 62061 SIL Claim
Safe link module 773540 PNOZml1p 168.03 793400 4.24 783400 4.24
List List ListDescription Ident No Order Code Price Order Code Price Order Code Price
Screw terminals Spring-loaded terminals
PNOZmulti Safe link modules Where required, up to four PNOZmulti base units can be used
to monitor and control morecomplex machinery. In this case,
the Safe link module enables data
to be exchanged between thePNOZmulti base units. With the modular PNOZmulti, up tosix PNOZ ml1p link modules can beconnected to each base unit (in either ring or tree structure).
Using the PNOZmulti Configurator,you can quickly and easily allocate theinformation to be transferred,
without specialist knowledge of safebus systems, or specifically addressing
the devices.
Technical specificationConnections . . . . . . . . . . . . . . . . . Plug in
Machine 1 Machine 2 Machine n
4-core cable4-core cable
Cat 4EN 954-1 CategoryPLeEN ISO 13849-1 Performance Level
SIL CL 3EN 62061 SIL Claim
8/10/2019 Safety Relay Catalogue Products
12/18
Safety relays www.lcautomation.com
Blackburn Office - 01254 685900 Chippenham Office - 01249 460099476
PNOZmulti input expansion modulesFeaturesPNOZ ma1p (analogue)
Range monitoring (4 range limits canbe configured)
Threshold value monitoring (8 limit values can be configured)Input voltage range: -10.24 to+10.2375V Input current range: 0-25.59mA Installed to the left of the base unit
A maximum of 4 PNOZ ma1p unitscan be connected to the base unitStatus indicators
PNOZ mi1p / mi2p (digital) A maximum of 8 input modules canbe connected to the base unit
Connect to base unit using jumperson the back of the unit
Technical specificationConnections . . . . . . . . . . . . . . . . . Plug in
PNOZmulti output expansion modulesFeaturesPNOZ mo1p
4 safe semiconductor outputs(2A, 24V d.c.)
PNOZmo2p:2 N/O safe outputs (6A, 24V)
PNOZmo3p:2 safe semiconductor outputs(2A, 24V d.c.)
PNOZmo4p:4 N/O safe outputs (6A, 24V)
PNOZmc1p:16 non-safety, auxiliary outputs
Technical specificationConnections . . . . . . . . . . . . . . . . . Plug in
A maximum of 8 modules can beattached to an expandablePNOZmulti base unit (on the right).
You cannot connect more than 6semiconductor safe output modulesper base. All expansion modulesconnect to the base using jumpers on
the back of the unit.
Cat 4EN 954-1 CategoryPLeEN ISO 13849-1 Performance Level
SILCL 3EN 62061 SIL Claim
Cat 3EN 954-1 CategoryPLdEN ISO 13849-1 Performance Level
SIL CL 2EN 62061 SIL Claim
2 safe analogue input module 773812 PNOZma1p 337.778 safe digital input module 773400 PNOZmi1p 134.948 standard digital input module 773410 PNOZmi2p 112.02
793700 5.09793400 4.24793400 4.24
783700 5.09783400 4.24783400 4.24
List List ListDescription Ident No Order Code Price Order Code Price Order Code Price
Screw terminals Spring-loaded terminals
4 safe semiconductor outputs 773500 PNOZmo1p 181.622 N/O safe outputs 773520 PNOZmo2p 144.272 safe semiconductor outputs 773510 PNOZmo3p 193.494 N/O safe outputs 773536 PNOZmo4p 157.0016 standard (non-safety) auxiliary outputs 773700 PNOZmc1p 229.31
793400 4.24793520 2.13793400 4.24793536 4.24793700 5.09
783400 4.24783520 2.13783400 4.24783536 4.24783700 5.09
List List ListDescription Ident No Order Code Price Order Code Price Order Code Price
Screw terminals Spring-loaded terminals
8/10/2019 Safety Relay Catalogue Products
13/18
Safety relays www.lcautomation.com
477Blackburn Office - 01254 685900 Chippenham Office - 01249 460099
EtherCAT module 773710 PNOZmc2p 428.95Profibus module 773732 PNOZmc3p 312.09DeviceNet module 773711 PNOZmc4p 313.53CANopen module 773712 PNOZmc6p 342.04CC-link module 773726 PNOZmc7p 395.54Ethernet IP/Modbus TCP module 773730 PNOZmc8p 398.54Profinet IO module 773731 PNOZmc9p 398.54
PNOZmulti fieldbus communication modules
ListDescription Ident No Order Code Price
Fieldbus communication modulescan help to integrate thePNOZmulti into your machine or plant control network.
All these modules can be configuredusing the PNOZmulti Configurator.Please note; only one commsmodule can be connected per PNOZmulti base unit.
The speed monitor canindependently monitor two axesfor standstill, speed and directionof rotation.
The speed monitor signals the statusof the monitored values to the baseunit. Depending on the safety circuitloaded, the values can be transferred
from the base unit to a relay output ona safety system, for example.Incremental encoders or proximityswitches can also be used to record
the values.
PNOZmulti safe speed and standstill monitor
Features
Monitoring of 2 independent axesConnection (per axis); 1 incrementalencoder, or 2 proximity switches, or 1 incremental encoder and1 proximity switch
Measured variables:StandstillSpeed (8 values can be set)Direction of rotation
Technical specificationInputsProximity switch . . . . N/O PNP, 24V d.c.Encoder . . . . Incremental with differential
output A + B supply 12-30V d.c.Input frequency . . . . 0.1-3kHz proximity
0.2-200kHz encoder Output signals . . . . . . . . . . . . . Standstill
over speed and faultIndication . . . . . . . . . . . . . . . . . Standstill
over speed and faultConnectionEncoder . . . . . . . . . . . . . . . . . . . . . RJ45Power and proximity . . . . . . . . . . Plug in
Cat 3EN 954-1 Category PLeEN ISO 13849-1 Performance LevelSIL CL 3EN 62061 SIL Claim
NEW
PNOZmulti Configurator
See page 480 for further details
Graphic tool for configuration and
programming of the PNOZmulti.
2 axis safe speed and standstill monitor 773815 PNOZms2pHTL 459.33RJ45 cable; 5m (for encoder) 773856 15.28
793800 2.54
783800 3.10
List List ListDescription Ident No Order Code Price Order Code Price Order Code Price
Screw terminals Spring-loaded terminals
8/10/2019 Safety Relay Catalogue Products
14/18
Safety relays www.lcautomation.com
Blackburn Office - 01254 685900 Chippenham Office - 01249 460099478
Decentralised input/output module
Up to 4 safety devices of any typecan be added to one decentralisedinput/output module. A network of up to 4 blocks can be built over 400m, and up to 4 networks can beconnected to one PNOZmulti or PNOZmulti Mini providing up to 64remote dual channel safety circuits.The decentralised input/outputmodules connect to PNOZmulti or PNOZmulti Mini via the Safe link module (see below).
FeaturesOne cable for communication andpower to a configurable PNOZmultior PNOZmulti Mini safety relay
8 single channel outputs can beconfigured as safe inputs, or standardoutputs (for monitoring)4 x M12 female 5 pin socketsfor connection to PSEN codeddevices, or non-coded devices1 x M12 male 5 pin failsafe socket for connection to PNOZmulti/Mini1 x M12 female 5 pin signalcascading socket2 x LEDs for sensor status andpower indication
Up to 4 Safe link modules can beadded to each PNOZmulti/MiniHigh power version also includes 2 xM12 24V d.c. ports for light curtaininputs and solenoid interlock outputs
Technical specificationConnection to PNOZ . . . . . M12 female
5 pin to open ended cablesConnection to PSEN . . . . . . M12 female
to M12 male cablesSupply voltage . . . . . . . . . . . . . . 24V d.c.(Note: When cascading volt drop limits to be observed)Current capacity . . . . . . . . . . . . . . . . 2A LED indication . . . . . . . . Response range
and locking commandProtection rating . . . . . . . . . . . . . . . IP67
Ambient temperature . . . -40 to +60CDimensions . . . . . h120 x w60 x d20mm
PDP67 F 8DI ION multi I/O interface 773600 136.84PDP67 F 8DI ION HP multi I/O interface high power version 773601 184.84
ListDescription Order Code Price
The Safe link module PNOZml2p enables safe inputs to beconveniently distributed acrossa machine, reducing cabling
time, effort and cost with theadded benefit of improveddiagnostics.
Technical specificationConnections . . . . . . . . . . . . . . . . . Plug in
PNOZm12p Safe link module
Cat 4EN 954-1 CategoryPLeEN ISO 13849-1 Performance Level
SIL CL 3EN 62061 SIL Claim
M12, 5 pin, open 630311 15.70 630297 47.42
List List List List ListDescription Order Code Price Order Code Price Order Code Price Order Code Price Order Code Price
5m
630310 13.60
3m 30m
630312 22.09
10m
630298 33.47
20m
PNOZmulti connection cables
Safe link module for PDP67 F 8DI ION 773602 PNOZml2p 182.56 793400 4.24 783400 4.24
List List ListDescription Ident No Order Code Price Order Code Price Order Code Price
Screw terminals Spring-loaded terminals
M12-M12, 5 pin, angled*M8-M12, 4 pin, angled
380213 30.29380205 21.61
380215 59.93380207 51.26
List List List ListDescription Order Code Price Order Code Price Order Code Price Order Code Price
5m
380212 27.91380204 19.24
2m 30m
380214 36.22380206 27.54
10mPSEN connection cables
*Can also be used for cascading the PDP67 F 8DI ION modules.
8/10/2019 Safety Relay Catalogue Products
15/18
Safety relays www.lcautomation.com
479Blackburn Office - 01254 685900 Chippenham Office - 01249 460099
Reduce installation and wiringcosts, and increase machinemodularity and diagnostics by linking up to 4 coded safety devices(e.g. PSENcode, PSENslock)
through one passive decentralisedsafety module on the machine.
FeaturesOne cable for communication and
power to a PNOZSigma or PNOZmulti safety relay Maximum performance levelPLe (ENISO13849-1)4 x M12 female 8 pin sockets for connection to PSEN coded devices1 x M12 female 8 pin failsafe socketfor connection to PNOZ relay 1 x M12 female 8 pin signal socket for connection to standard controlsystem (e.g. PLC)LEDs for sensor status indication
(sensor status and locking) and power Supplied with 1 x PDP connector csfor cascading or connection to PNOZ(requires a separate cable); labels and4 blanking plugs for unused sockets
Technical specificationConnection to:
PNOZ . . . . . . . . . . . . . . . . . . M12 male8 pin to open ended cables
PSEN . . M12 female to M12 male cablesSupply voltage . . . . . . . . . . . . . . 24V d.c.(Note: When cascading volt drop limits to be observed)Current capacity . . . . . . . . . . . . . . . . 2A 2 LED indication . . . . . . Response range
and locking commandProtection rating . . . . . . . . . . . . . . . IP67
Ambient temperature . . . -40 to +60CCascading cable . . . . . PDP67 connector
F4 cs adapter (supplied)
Dimensions . . . . . h120 x w60 x d20mm
Decentralised passive safety modules forcoded safety devices
PDP67 F4 code (passive junction) 773603 73.30PDP67 connector F4 cs (spare for cascading) 773610 16.63
ListDescription Order Code Price
M12, 8 pin, open 540320 17.67 540326 59.13
List List List List ListDescription Order Code Price Order Code Price Order Code Price Order Code Price Order Code Price
5m
540319 14.83
3m 30m
540321 24.12
10m
540333 47.79
20m
PNOZ connection cables
M12-M12, 8 pinPSEN adaptor
540341 29.09380301 22.25
540344 66.12380301 22.25
List List List List ListDescription Order Code Price Order Code Price Order Code Price Order Code Price Order Code Price
5m
540340 26.66380301 22.25
2m 30m
540342 37.74380301 22.25
10m
540343 66.53380301 22.25
20m
PSEN connection cables
8/10/2019 Safety Relay Catalogue Products
16/18
Safety relays www.lcautomation.com
Blackburn Office - 01254 685900 Chippenham Office - 01249 460099480
PNOZmulti tool kit 779000 118.82Basic single user licence 773010B 321.79
ListDescription Order Code Price
The tool kit contains theaccessories you need to start
working with PNOZmulti:Documentation folder with thePNOZmulti Configurator software(does not include a user licence)10 x 32Kb chip cardsChip card reader Configuration cable for readingdiagnostic data
Basic single user licence 773010B 321.79Upgrade licence 773010U 148.51RS232 programming cable 310300 29.25RS232 to USB adaptor 305160 42.45Chipcard 8Kb 779201 5.23Chipcard 32Kb 779211 7.39Chipcard reader 779230 38.19
PNOZmulti Configurator and accessories
Graphic tool for configuration andprogramming of the PNOZmulti. Project configuration, configuration
generation, documentation,commissioning
Data transfer via RS232 serial cableor chip card
User interface in German, English,French, Italian, Spanish, Japaneseor Chinese
The software is constantly evolving,but you can download the latest
version from www.pilz.co.uk/. You will also need to order a basic user licence from the price table below.
Function elements include:E-stops, safety gates, light curtains,muting, two hand control, enablingdevices, foot mats, zero/safe speed,analogue inputPress elements (e.g. operating mode,rotary cam)Burner managementPilz Visual (PVIS) expandeddiagnosticsMacros
Logic elements include:Boolean functions AND, OR, XOR,NOT, EQU, RS FLIP-FLOPTimers on and off delay, pulse trainsEvent counters
ListDescription Order Code Price
Standard PC requirementsOperating system: Windows 2000,
XP, Vista(32 Bit) or 7 (32 or 64 Bit)Processor: Minimum 1GHz
RAM: Minimum 1,024MbHard drive: 20Gb with a minimumof 15Gb of available disc space
PNOZmulti Configurator tool kit
8/10/2019 Safety Relay Catalogue Products
17/18
Safety relays www.lcautomation.com
481Blackburn Office - 01254 685900 Chippenham Office - 01249 460099
PAScal safety calculator
PAScal allows users to validatesafety functions to both EN ISO13849-1 and EN/IEC 62061. Simple handling saves time
very easy to use compared toother tools on the market
Comprehensive componentdatabase
Simple import and updatefunction
Report Generator asdocumentary evidence(required by the standards)
The software is constantly evolving,but you can download the latest
version from www.pilz.co.uk/. You will also need to order a basic user
licence from the price table below. You can downloaded and run a demolicence version of PAScal, which givesyou access to just the essential
functionality. Purchasing a user licenceallows you to have more than threesafety functions per project and toedit reports after generation.
FeaturesCalculates the PFH D value of safety functions on plant and machinery The result is verified with the
prescribed performance level (PL) inaccordance with EN ISO 13849 or safety integrity level (SIL) inaccordance with EN/IEC 62061The graphical representation showshow individual components influenceoverall safety PAScal is compatible with a widerange of Sistema .SLB libraries, whichcan simply be imported
PAScal single user license 850050B 246.70Additional PAScal user license 850050K 183.87
ListDescription Order Code Price
Compatible with both
EN ISO 13849-1 andEN/IEC 62061
8/10/2019 Safety Relay Catalogue Products
18/18
Safety relays www.lcautomation.com
We supply highquality products from
these world leadingsuppliers . . .
www.lcautomation.com
Recommended