VD.CU.A1.02 Produced by Danfoss Floor Heating Hydronics 06.2008
Room ThermostatsFloor Heating
2
Data sheet FH-CWT/ CWD/ CWP Floor Heating Room Thermostats
VD.CU.A1.02 Produced by Danfoss Floor Heating Hydronics 06.2008
The room thermostats are available in three versions; two standard room thermostats with respectively dial or with LCD display and a programmable room thermostat with LCD display. All Room Thermostats are used for room temperature control in water based floor heat-
ing systems. By controlling room temperature in accordance with the temperature desired by the user the room thermostats provide optimal energy savings whilst upholding optimal thermal comfort in the room/ apartment.
Floor Heating Room Thermostats
Functions
Application
Room Thermostat, FH-CWT (Dial)By turning the dial to the desired set-point temperature optimal thermal comfort in the room is achieved. In addition to temperature the thermostat setting scale includes frost symbol allowing for minimal energy consumption while keeping the room from freezing. The thermo-stat is equipped with diodes which through the front cover will display a green light while the thermostat is ON but without heat demand and a red light when the thermostat is ON and there is heat demand.
Room Thermostats, FH-CWD (display) and FH-CWP (display and programmable) The thermostats with LCD display can in addi-tion to room temperature control be equipped with floor sensor thus allowing for control of maximum floor temperature and reducing risk of over heated and damaged floors. For specific maximum floor temperatures please refer to recommendations from floor suppliers.
Using the Frost Protection Mode instead of turn-ing the thermostat OFF completely may protect against damages due to low temperatures. The room temperature will be maintained around 5°C.
For the FH-CWP (programmable thermostat) two timer programs are available allowing tempera-ture setback or alternatively complete turning off the heat supply during selected periods without occupants in the room/ apartment.
The ON/ OFF Timer Function allows you to pro-gram the thermostat for one period with heating turned OFF and one period with heating turned ON per day. During the ON period the thermostat will regulate in relation to the set temperature and TIMER ON will be shown in the display. Dur-ing the OFF period, the heating is off, and TIMER OFF is shown in the display.
The Advanced Programmable Timer Function allows you to set a timer controlled program for automatic comfort temperature and energy saving lower setback temperature when standard room comfort temperature is not required.The Advanced Programmable Timer Function allows for 4 different periods / 5+2 days per week.
FH-CWT FH-CWD FH-CWP
Ordering Product Type Supply voltage Output voltage Code no.
Room Thermostat - Dial FH-CWT 230 Vac 230 Vac 088U0601
Room Thermostat - Display FH-CWD 85-250 Vac 85-250 Vac 088U0602
Room Thermostat - Display Programmable FH-CWP 85-250 Vac 85-250 Vac 088U0603
Floor sensor FH-CWF – – 088U0610
3
Data sheet FH-CWT/ CWD/ CWP Floor Heating Room Thermostats
Produced by Danfoss Floor Heating Hydronics 06.2008 VD.CU.A1.02
Data Feature FH-CWT FH-CWD FH-CWP
Approval: CE Marking, EN 60730 CE Marking, EN 60730 CE Marking, EN 60730
Colour White RAL 9016/ Grey RAL 7011
White RAL 9016 White, RAL 9016
Dimensions 86 x 99 x 29 mm 86 × 99 ×19mm 86 × 99 ×19mm
Ambient temperature -10˚C - 60˚C -10˚C - 60˚C -10˚C - 60˚C
Operating rating 0˚C - 40˚C, 5 - 95% RH (Non-condensing)
0˚C - 40˚C, 5 - 95% RH (Non-condensing)
0˚C - 40˚C, 5 - 95% RH (Non-condensing)
Adjustment mode Dial Push buttons Push buttons
Fault indication/ failure mode
If sensor failure, thermo-stat will turn off all output of relays.
If room sensor failure, E1 will be displayed. If floor sensor failor, E2 will be displayed. In any case, thermostat will turn off all output of relays.
If room sensor failure, E1 will be displayed. If floor sensor failor, E2 will be displayed. In any case, thermostat will turn off all output of relays.
Frost protection Yes, put the dial to position (5° C)
Yes, if enabled:<5˚C heating on >7˚C heating off
Yes, if enabled:<5˚C heating on >7˚C heating off
Precision ±1° C ±0.5° C ±0.5° C
Hysteresis 1°C, below the setpoint temperature
1°C, symmetrical around the setpoint temperature
1°C, symmetrical around the setpoint temperature
IP class 30 30 30
LCD backlight/nightlight No Yes Yes
LCD display No Yes Yes
LED indicator Green light: Thermostat ON and no heat demandRed light: Thermostat ON and heat demand
No No
Max load, inductive <1A <1A <1A
Max load, resistive <3A <3A <3A
Mounting Wall mounting Flush Mounting for Euro-pean and Chinese built in sockets
Flush Mounting for Euro-pean and Chineese built in sockets
Network, wire No No No
Network, wireless No No No
Off-set function/ Temp. calibration
No Yes (+/-10°C) Yes (+/-10°C)
Power consumption 7W 2 W 2 W
Power supply, battery No No No
Power supply, net 230Vac±10% 50/60Hz 85-250Vac 50/60Hz 85-250Vac 50/60Hz
Power backup settings Not applicable Retains settings in case of power cut saved on memory chip
Retains settings in case of power cut saved on memory chip
Sensor, floor No Optional, 2 terminals (S1, S2) for external sensor mounting. Sensor type NTC 10K accuracy: ±1%
Optional, 2 terminals (S1, S2) for external sensor mounting. Sensor typeNTC 10K accuracy: ±1%”
Sensor, floor - set range No 20-45°C 20-45°C
Sensor, room NTC 10K accuracy: ±1% NTC 100K accuracy: ±1% NTC 100K accuracy: ±1%
Sensor, room - set range 5-30°C 5-35°C 5-35°C
Shell material/ non inflam-mable
94V0/ Yes 94V0/ Yes 94V0/ Yes
Shell material, type ABS+PC ABS+PC ABS+PC
Static protection Yes Yes Yes
Programmable
No No Two program functions1. ON/ OFF program 2 periods/ day2. Periode program for automatic comfort temperature and setback temperature 4 periods/ 5+2 days
4
Data sheet FH-CWT/ CWD/ CWP Floor Heating Room Thermostats
VD.CU.A1.02 Produced by Danfoss Floor Heating Hydronics 06.2008
Application examples
Wiring connections
Room Thermostat, FH-CWT (Dial)
Individual room temperature control
Reference room temperature control
Reference room temperature control
Room Thermostat, FH-CWD (Display) Room Thermostat, FH-CWProgrammable)
( )
( )
Individual room temperature control
5
Data sheet FH-CWT/ CWD/ CWP Floor Heating Room Thermostats
Produced by Danfoss Floor Heating Hydronics 06.2008 VD.CU.A1.02
Dimensions
60
48
60 48
24,518,5
98,6
86
60
60 48
4824,518,5 86
98,6
60
60
29,5 86
98,6
Room Thermostat, FH-CWT (Dial)
Room Thermostat, FH-CWD (Display)
Room Thermostat, FH-CWP (Programmable)
6006
1 00
0 01
6
Data sheet FH-CWT/ CWD/ CWP Floor Heating Room Thermostats
Produced by Danfoss Floor Heating Hydronics 06.2008 VD.CU.A1.02
6001
� 00
0 02
12
Data Sheet CF2 Wireless Floor Heating Control System
VD.UH.J2.02 Produced by Danfoss Floor Heating Hydronics 10.2005
Recommended