Rohde & Schwarz solutions for EMI

Preview:

Citation preview

High-Quality Equipment for your EMI demands

www.rohde-schwarz.com

Group of equipment

Indu

stria

l, sc

ient

ific

and

med

ical

equ

ipm

ent

Vehi

cles

, boa

ts a

nd in

tern

al c

ombu

stio

n en

gine

s

Soun

d an

d TV

bro

adca

st re

ceiv

ers

Elec

trica

l dev

ices

,ho

useh

old

appl

ianc

es a

nd to

ols

Fluo

resc

ent l

amps

and

lum

inai

res

Info

rmat

ion

tech

nolo

gy a

nd

tele

com

mun

icat

ions

equ

ipm

ent (

ITE)

Mili

tary

equ

ipm

ent a

nd s

yste

ms

Gene

ric e

mis

sion

sta

ndar

ds

Mai

ns s

igna

ling

equi

pmen

t

Cabl

ed d

istri

butio

n sy

stem

s TV

/sou

nd

Unin

terr

uptib

le p

ower

sys

tem

s (U

PS)

Prof

essi

onal

aud

io/v

ideo

equ

ipm

ent

Elec

tric

railw

ays

Med

ical

ele

ctric

al a

ppar

atus

Mar

itim

e na

viga

tion

equi

pmen

t

Low

-vol

tage

sw

itchg

ear a

nd c

ontro

l gea

r

Tele

com

sys

tem

s of

larg

e di

men

sion

s

Shor

t ran

ge d

evic

es (S

RD)

9 kH

z to

40 G

Hz

PMR

equi

pmen

t, DE

CT e

quip

men

t

Gene

ric E

MC

stan

dard

for r

adio

equ

ipm

ent

ERM

ES p

agin

g re

ceiv

ers

GSM

900

 MHz

GSM

180

0 M

Hz

Fixe

d ra

dio

links

Wire

less

mic

roph

ones

and

sim

ilar e

quip

men

t

Seco

nd-g

ener

atio

n co

rdle

ss te

leph

ones

(CT2

)

VHF

FM b

road

cast

ing

trans

mitt

ers

VSAT

, SN

G an

d TE

S eq

uipm

ent

CB ra

dio

and

anci

llary

equ

ipm

ent

On-s

ite a

nd w

ide-

area

pag

ing

equi

pmen

t

Com

mer

cial

ly a

vaila

ble

amat

eur r

adio

eq

uipm

ent

2.4 

GHz w

ideb

and

trans

mis

sion

and

HIPE

RLAN

TETR

A an

d an

cilla

ry e

quip

men

t

VHF

mar

itim

e m

obile

radi

o te

leph

one

1.5 

GHz r

ecei

ve-o

nly

MES

for d

ata

com

mun

icat

ions

1.5/

1.6/

2/2.

4 GH

z MES

for s

atel

lite

GSM

< 1

 GHz

MES

with

LBR

DC u

sing

LEO

s

Legend

b Necessary accessory.v Recommended extra.1) R&S®ESRP and R&S®ESL have limited compliance with CISPR 16-1-1.2) For FCC Part 15 only. 4) VG up to 200 kHz. 5) VG.6) VG, MIL, MIL-STD-461D, MIL-STD-461E. 7) VG, DEF-STAN.8) See R&S®EZ-25.9) For MIL-STD-461 only.

Standards

Inte

rnat

iona

lEu

rope

and

Ger

man

yJa

pan

USA

CISP

R 11

EN 5

5011

; VDE

087

5 Pa

rt 11

J550

01FC

C Pa

rt 18

, Sub

part

C

CISP

R 12

/CIS

PR 2

5; E

CE 1

0EN

550

12; V

DE 0

879

Part

1, 2

, 3JA

SO D

001-

82SA

E J

551,

J 1

113

CISP

R 13

EN 5

5013

; VDE

087

2 Pa

rt 13

J550

13– CI

SPR

14-1

EN 5

5014

-1; V

DE 0

875

Part

14J5

5014

-1– CI

SPR

15EN

550

15; V

DE 0

875

Part

15-1

J550

15– CI

SPR

22EN

550

22; V

DE 0

878

Part

22J5

5022

FCC

Part

15, S

ubpa

rt B

– DEF-

STAN

59-

411

(UK)

; VG

9537

0/95

373

– MIL

-STD

-461

EN 6

1000

-6-3

/4

EN 5

0065

-1

EN 5

0083

-2

EN 5

0091

-2

CISP

R 32

; EN

551

03-1

EN 5

0121

-x

EN 6

0601

-1-2

EN 6

0945

EN 6

0947

-x-x

EN 3

0012

7

EN 3

0022

0, 3

30, 4

40EN

301

489-

3

EN 3

0148

9-5

EN 3

0148

9-6

EN 3

0033

9EN

301

489-

1

ETS

3003

40

EN 3

0148

9-7

EN 3

0038

5EN

301

489-

4

EN 3

0148

9-9

EN 3

0148

9-10

EN 3

0148

9-11

EN 3

0201

8-2

ETS

3003

84/4

47

EN 3

0148

9-12

EN 3

0148

9-13

EN 3

0074

1EN

301

489-

2

EN 3

0148

9-15

EN 3

0178

3-2

EN 3

0148

9-17

EN 3

0148

9-18

EN 3

0184

3-2

EN 3

0148

9-19

EN 3

0083

1EN

301

489-

20

EN 3

0083

2EN

301

721

Frequency range

Test receivers Accessories and extras

From 20 Hz R&S®ESUR&S®ESR with -B29R&S®ESRP 1)with -B29

R&S®EZ-17 current probe b Current probe from 5 Hz to 2 MHz/20 Hz to 100 MHz

R&S®HZ-10 H-field pickup coilb b

Shielded, calibrated field pickup coil from 5 Hz to 10 MHz

From 9 kHz R&S®ESUR&S®ESRR&S®ESRP 1)

R&S®ESL 1)

R&S®EZ-17 current probe v v v v v v v v v b Current probe from 20 Hz to 100 MHz

R&S®EZ-25 150 kHz highpass v v v v v v v v b v v v v v v v v v v v v v v v v v v v v v v v v v v v Passband from 150 kHz to 30 MHz

R&S®HZ-10 H-field pickup coil b 4) b Shielded, calibrated field pickup coil from 5 Hz to 10 MHz

R&S®HFU-Z tripod b b 5) b b b b Tripod for R&S®HFH2-Z2 loop antenna

R&S®HFH2-Z2 loop antenna b b 5) b b b b Active loop antenna from 9 kHz to 30 MHz

R&S®HZ-1 tripod b Tripod for R&S®HFH2-Z6 rod antenna

R&S®HFH2-Z6 rod antenna b b 6) Active rod antenna from 9 kHz to 30 MHz

R&S®ESH2-Z5 V-network b b b b b b 6) b b 8) b b b b b b b b b b b b b b b b b b b b b b b b b b V-network up to 25 A, four-line LISN

R&S®ESH3-Z6 V-network b b b b b b b b b b b V-network up to 150 A (500 A), single-phase LISN

R&S®ENV216 V-network b b b b b b 6) b b 8) b b b b b b b b b b b b b b b b b b b b b b b b b b V-network up to 16 A, two-line LISN

R&S®ENV4200 V-network b b b b b b b 8) b b b b b b b b b b b b b b b b b b b b b b b b b b V-network up to 200 A, four-line LISN, from 150 kHz

R&S®ENY21 coupling network b Two-wire ISN from 150 kHz

R&S®ENY41 coupling network b Four-wire ISN from 150 kHz

R&S®ENY81 coupling network b Eight-wire ISN from 150 kHz

R&S®ESH2-Z2 voltage probe b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b Active probe for disturbance voltage measurement

R&S®ESH2-Z3 voltage probe b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b Passive probe for disturbance voltage measurement

R&S®EZ-12 antenna imp. converter b Antenna impedance converter from 9 kHz to 30 MHz

R&S®HZ-14 probe set v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v Near-field probe set from 9 kHz to 1 GHz

R&S®HM020 triple-loop antenna v b b v v Triple-loop antenna from 9 kHz to 30 MHz

R&S®HZ-3/HZ-4 RF cable v b b b b b Low-loss coaxial cables, length: 3 m/10 m

R&S®HZ-9 power supply b b b b b b b Power supply for R&S®HFH2-Z2/-Z6 active antennas and R&S®EZ-12 antenna impedance converter

From 30 MHz R&S®ESUR&S®ESRR&S®ESRP 1)

R&S®ESL 1)

R&S®EZ-17 current probe v v v v v b b v v Current probe from 20 Hz to 100 MHz

R&S®ESV-Z1 current probe v v v v v b v v Current probe from 20 Hz to 600 MHz

R&S®MDS-21 absorbing clamp b b b b b b b b b Absorbing clamp from 30 Hz to 1000 MHz

R&S®HZ-14 probe set v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v Near-field probe set from 9 kHz to 1 GHz

R&S®HZ-15 probe set v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v Near-field probe set from 30 MHz to 3 GHz

R&S®HK116 biconical antenna b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b Biconical antenna from 30 MHz to 300 MHz

R&S®HL223 log-periodic antenna b b b b b b 7) b b b b b b b b b b b b b b b b b b b b b b b b b b b b Log-periodic antenna from 200 MHz to 1300 MHz

R&S®HL562E ULTRALOG antenna b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b Biconical hybrid antenna from 30 MHz to 6 GHz

R&S®HZ-1 tripod b Tripod for R&S®HK116, R&S®HL223

R&S®HFU2-Z4/-Z5 RF cable b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b RF connecting cable, length: 12 m/7 m, common-mode suppression

From 1 GHz R&S®ESUR&S®ESRR&S®ESRP 1)

R&S®ESL 1)

R&S®HL050, R&S®HF907 antennas b b b b b b Directional antenna from 1 GHz to 18 GHz, e.g. log-periodic antenna, or double-ridged waveguide horn antenna

Other antennas on requestb

From 3 GHz R&S®ESUR&S®ESRR&S®ESRP 1)

R&S®HL050, R&S®HF907 antennas b b b b b b

Other antennas on requestb

From 6 GHz R&S®ESRR&S®ESU

R&S®HL050, R&S®HF907 antennas b b b 2) b b b

Other antennas on request b b

From 18 GHz to 26.5/40 GHz

R&S®ESR26R&S®ESU26/40

Accessories b 2) b 9) b b b Double-ridged waveguide horn antenna

Other antennas on request

¸ENV 216 Two-Line V-Network

Rohde & Schwarz solutions for EMI

¸EZ-17 Current ProbeR&S ESRP EMI Test Receiver (with option R&S®FSV-B1) ¸ESU EMI Test Receiver

¸ESR EMI Test Receiver ¸ENY Coupling Networks¸ESL EMI Test Receiver ¸HL562E Log-Periodic Antenna

5213

.663

5.82

V 0

4.00

5213663582

EMI_Standards_Poster_5213-6635-82.indd 1 19.03.2014 17:21:36

Recommended