Rental Accessories - Kohler Power · Rental Accessories Kohler Rental Power provides one-source...

Preview:

Citation preview

G32-4 11/04d Page 1

TM Power Distribution Packs

Rental Accessories

� Kohler Rental Power provides one-sourceresponsibility for the generating system andaccessories.

� Select from a wide variety of power distributionconfigurations to meet your application needs.

� Nine models are available with UL NEMA 3R listing.

� The rubber enclosure power distribution packtypically has individual circuit breaker protection andquick setup with color-coded, cam-type electricalconnections or a twist-lock connector.

30 Amp Quad Box

DB200NT-ALL-S3

Model Number DB200NT-ALL-S3

Agency Approval UL NEMA 3R

Rating 150 A, 208Y/120 V, 3-phase, 60 Hz, 4-wire

Input Five inline male cam connectors, 16 series tails

Output Five L21-30, 30 A,120/208 V, 3-phase,weatherproof receptacles

BreakerConfiguration

Five 30 A, 3-pole, branchcircuit-rated breakers

Overall Dimensions,L x W x H, mm (in.)

279 x 279 x 356(11 x 11 x 14)

Weight, kg (lb.) 15.9 (35)

30 Amp RV Distribution Box

7506G

Model Number 7506G

Agency Approval UL NEMA 3R

Rating 150 A, 208Y/120 V, 3-phase, 60 Hz, 4-wire

Input Four male panel mount minicam connectors,100 A/220 V

Output Four 30A, TT--30R, 125 V, 1-phase straight bladereceptacle, see View AFour 20 A, duplex 5-20R, 125 V, 1-phasenon-GFI receptacle, see View B

View A View B

G

G

W

BreakerConfiguration

Four 30 A, 1-pole branch circuit-rated breakersFour 20 A, 1-pole branch circuit-rated breakers

Overall Dimensions,L x W x H, mm (in.)

533 x 381 x 279(21 x 15 x 11)

Weight, kg (lb.) 13.2 (29)

G32-4 11/04d Page 2

50 Amp RV to 6-5/20 NEMA

DB50A-SPZ620FT

Model Number DB50A-SPZ620FT

Agency Approval UL NEMA 1

Rating 50 A, 120/240 V, 1-phase, 60 Hz, 3-wire

Input One CS63-65, 50 A plug, one feed throughCS63-69, 50 A, single locking receptacle

Output Six 20 A duplex receptacles,5-20R 125 V, non GFI G

W

BreakerConfiguration

Six 20 A, 1-pole, branchcircuit-rated breakers

Overall Dimensions,L x W x H, mm (in.)

358.3 x 368.3 x 317.5(14.5 x 14.5 x 12.5)

Weight, kg (lb.) 12.2 (27)

100 Amp Quad Box

DB100A-SPZ1000

Model Number DB100A-SPZ1000

Agency Approval UL NEMA 3R

Rating 100 A, 208Y/120 V, 3-phase, 60 Hz, 4-wire

Input Five inline male cam connectors, 16 series tails

Output Five L21-20, 20 A,120/208 V, 3-phase,weatherproof receptacles

BreakerConfiguration

Five 20 A, 3-pole, branchcircuit-rated breakers

Overall Dimensions,L x W x H, mm (in.)

317.5 x 317.5 x 317.5(12.5 x 12.5 x 12.5)

Weight, kg (lb.) 12 (26.5)

100 Amp RV Distribution Box

DB100A-SPZ6369

Model Number DB100A-SPZ6369

Agency Approval UL NEMA 3R

Rating 100 A, 208Y/120 V, 3-phase, 60 Hz, 4-wire

Input Five inline male cam connectors, 16 series tails

Output Four CS-63-69, 50 A,125/250 V, 1-phase,4-wire, weatherprooflocking receptacles

X

W

Y

G

BreakerConfiguration

Four 50 A, 2-pole, branch circuit-rated breakers

Overall Dimensions,L x W x H, mm (in.)

317.5 x 317.5 x 317.5(12.5 x 12.5 x 12.5)

Weight, kg (lb.) 12.2 (27)

G32-4 11/04d Page 3

100 Amp Minicam Distribution Box

DBSPZ-100A-MC

Model Number DBSPZ-100A-MC

Agency Approval UL NEMA 3R

Rating 100 A, 208Y/120 V, 3-phase, 60 Hz, 4-wire

Input Five inline male cam connectors, 16 series tails

Output Two rows 60 A, 220 V, 1-phase, panel mountminicamsTwo rows 100 A, 220 V, 1-phase, panel mountminicams

BreakerConfiguration

Two 60 A, 2-pole, branch circuit-rated breakersTwo 100 A, 2-pole, branch circuit-rated breakers

Overall Dimensions,L x W x H, mm (in.)

317.5 x 317.5 x 317.5(12.5 x 12.5 x 12.5)

Weight, kg (lb.) 14.5 (32)

100 Amp 3-Phase to Multiple 30 Amp and 20 Amp, 1-Phase Outputs

DBC100DP-A4T3

Model Number DBC100DP-A4T3

Agency Approval UL NEMA 3R

Rating 100 A, 208Y/120 V, 3-phase, 60 Hz, 4-wire

Input Five male panel mount cams, 16 series

Output

View D View E

Two 30 A, TT-30R, 125 V, 1-phase, straight bladereceptacles, see View ATwo 30 A, L5-30R, 125 V, 1-phase, lockingreceptacles, see View BTwo 30 A, L6-30R, 250 V, 1-phase, lockingreceptacles, see View COne 30 A, L14-30R, 125/250 V, 1-phase, lockingreceptacle, see View DOne 20 A, L6-20R, 250 V, 1-phase, lockingreceptacle, see View E

View A View B View C

G

BreakerConfiguration

Four 30 A, 1-pole branch circuit-rated breakersThree 30 A, 2-pole branch circuit-rated breakersOne 20 A, 2-pole branch circuit-rated breaker

Overall Dimensions,L x W x H, mm (in.)

279.4 x 279.4 x 330.2(11 x 11 x 13)

Weight, kg (lb.) 14.5 (32)

G32-4 11/04d Page 4

200 Amp Quad Box

DB200A-F201000

Model Number DB200A-F201000

Agency Approval UL NEMA 3R

Rating 200 A, 208Y/120 V, 3-phase, 60 Hz, 4-wire

Input Five male panel mount cams, 16 series

Output Ten L21-20, 20 A,120/208 V, 3-phase,weatherproof receptacles

BreakerConfiguration Ten 20 A, 3-pole, branch circuit-rated breakers

Overall Dimensions,L x W x H, mm (in.)

381 x 444.5 x 558.8(15 x 17.5 x 22)

Weight, kg (lb.) 28.6 (63)

200 Amp RV Distribution Box

DB200AXO16369

Model Number DB200A-XO16369

Agency Approval UL NEMA 3R

Rating 200 A, 208Y/120 V, 3-phase, 60 Hz, 4-wire

Input Five inline male cam connectors, 16 series tails

Output Eight CS-63-69, 50 A,125/250 V, 1-phase,4-wire, weatherprooflocking receptacles

X

W

Y

G

BreakerConfiguration

Eight 50 A, 2-pole, branchcircuit-rated breakers

Overall Dimensions,L x W x H, mm (in.)

508 x 508 x 355.6(20 x 20 x 14)

Weight, kg (lb.) 24 (53)

200 Amp Minicam Distribution Box

DBXO1/6CAM

Model Number DBXO1/6CAM

Agency Approval UL NEMA 3R

Rating 200 A, 208Y/120 V, 3-phase, 60 Hz, 4-wire

Input Five inline male cam connectors, 16 series tails

Output Six rows 100 A, 220 V, 1-phase, panel mountminicams

BreakerConfiguration Six 100 A, 2-pole, branch circuit-rated breakers

Overall Dimensions,L x W x H, mm (in.)

508 x 508 x 355.6(20 x 20 x 14)

Weight, kg (lb.) 24.9 (55)

G32-4 11/04d Page 5

400 Amp Multibox

DBF20-MULTI

Model Number DBF20-MULTI

Agency Approval UL NEMA 3R

Rating 400 A, 208Y/120 V, 3-phase, 60 Hz, 4-wire

Input Five male panel mount cams, 16 series

Output Two rows 100 A, 220 V, 3-phase, panel mountminicams; two L21-20, 20 A, 120/208 V, 3-phase,weatherproof receptacles; see View AThree CS63-69, 50A, 125/250 V, 1-phase, 4-wire,weatherproof locking receptacles; see View BFour 20A, 125 V duplex receptacles; see View C

View A View B

X

W

Y

GView C

G

W

BreakerConfiguration

Two 100 A, 3-pole, branch circuit-rated breakersTwo 20 A, 3-pole, branch circuit-rated breakersThree 50 A, 2-pole, branch circuit-rated breakerFour 20 A, 1-pole, branch circuit-rated breakers

Overall Dimensions,L x W x H, mm (in.)

381 x 444.5 x 558.8(15 x 17.5 x 22)

Weight, kg (lb.) 31.8 (70)

400 Amp Cam-Type Breakout Box

DB400A-F202000

Model Number DB400A-F202000

Agency Approval UL NEMA 3R

Rating 400 A, 208Y/120 V, 3-phase, 60 Hz, 4-wire

Input Five male panel mount cams, 16 series

Output Four rows 100 A, 208 V, 3-phase, female panelmount cams, 16 series

Breaker Config. Four 100 A, 3-pole, branch circuit-rated breakers

Overall Dimensions,L x W x H, mm (in.)

381 x 444.5 x 558.8(15 x 17.5 x 22)

Weight, kg (lb.) 34 (75)

600 Amp Cam-Type Breakout Box

DB800-5704200

Model Number DB800-5704200

Agency Approval UL NEMA 3R

Rating 600 A, 208Y/120 V, 3-phase, 60 Hz, 4-wire

Input Two male panel mount cams, 3-phase, 16 seriesTwo rows of five for parallel input cables

Output Three rows 200 A, 3-phase, female panel mountcams, 16 series

Breaker Config. Three 200 A, 3-pole, branch circuit-rated

Overall Dimensions,L x W x H, mm (in.)

622.3 x 530.7 x 383.7 (24.5 x 20.5 x 15.5)with 88.9 (3.5) skids

Weight, kg (lb.) 47.2 (104)

Availability is subject tochangewithout notice.Kohler Co. reserves the rightto change the design or specifications without notice and without anyobligation or liability whatsoever. Contact your local Kohler� Rental Powerregional office for availability. 2001, 2002, 2004 by Kohler Co. All rights reserved.

DISTRIBUTED BY:

KOHLER CO., Kohler, Wisconsin 53044 USAPhone 920-459-1634; Fax 920-459-1846For the nearest sales and service outlet in the USA andCanada, call 1-888-769-3794 or kohlerrentalpower.com

TM

G32-4 11/04d Page 6

Recommended