View
2
Download
0
Category
Preview:
Citation preview
IJSTE - International Journal of Science Technology & Engineering | Volume 6 | Issue 8 | February 2020 ISSN (online): 2349-784X
All rights reserved by www.ijste.org
1
Removal of Heavy Metal Ions from Leachate
using Natural Adsorbent Delonix Regia
Dr. (Mrs.) Shilpa P. Kodolikar (Kulkarni) Dr. (Mrs.) Veena R. Doss
Assistant Professor Lecturer
Department of Chemical Engineering Department of Applied Science
MIT World Peace University, Pune, Maharashtra, India Higher College of Technology, Muscat, Oman
Abstract
In the present work, the adsorption of nickel ions from leachate sample by activated carbon prepared from seeds of Delonix
Regia was studied. The activated carbon prepared by pretreatment with KOH was subjected to SEM, XRD and FTIR analysis. The
influences of different experimental parameters on nickel uptake were investigated such as sorption time, final solution pH,
adsorbent dosage and temperature. The experimental data were correlated to different kinetic and adsorption models and
the corresponding kinetic parameters were determined. The % removal was found to be 75.03% and follows pseudo-
first order kinetic model for Ni. These parameters are considered fundamental for further studies involving the scale-up of the
process for continuous studies.
Keywords: Delonix Regia seeds Activated Carbon (DRAC), Leachate, Ni adsorption
________________________________________________________________________________________________________
I. INTRODUCTION
Landfill leachate is considered as a potential pollutant when it percolates through a waste disposal site depending on
composition and extent of decomposition of refuse and hydrological factors. There is growing concern for surface and ground
water pollution for which better understanding and prediction regarding its treatment is of prior importance. As water percolates
through a waste deposit it leaches various components present in it thus exhibiting high concentration of dissolved organics,
toxics, metals, color, odor, turbidity, pH, etc.[1][2]
The different methods for removal of heavy metals from wastewater include precipitation, coagulation, reduction
membrane process, ion exchange and adsorption. Adsorption as compared to other methods has advantages due to its simple
design and operation, sludge free and cost effectiveness [3]
Leachate can be defined as a potential hazardous waste from landfill sites. If not dealt properly they can cause pollution to
groundwater, health problems and effect the environment. It is important that leachates are treated and contained to prevent these
occurrences. Leachate pollution is the result of biological, chemical and physical processes that take place in landfills combined
with waste composition and landfill water regime. [4]
A wide range of new tertiary treatment processes has been developed on the enhanced coagulation–flocculation, clarification
and biological processes (aerated lagoons, activated sludge, anaerobic filters, stabilization ponds, up flow anaerobic sludge blanket,
sequence biological reactor, rotating biological contactors, and nitrification or denitrification processes) as possible circumstance
for leachate treatment, mainly hinges of its reliability, simplicity, high cost-effectiveness, reduction of stabilization time and
acceleration of biogas production[5][6]
Several studies have demonstrated use of natural adsorbent for removal of heavy metals in leachate.[7-18]. Mohan et
al[19] studied removal of heavy metal ions from municipal solid waste leachate using coal fly ash as an adsorbent. Foo
et al [20] carried out the study of leachate treatment using activated carbon .Nitrogen removal and heavy metals in leachate
treatment using SBR technology was done by Morling and group [21]. Nagwan et al [22] tried to remove some heavy metals from
leachate. Daga and group [23] reviewed low cost adsorbent for heavy metal removal from waste water.
Most of the world production of Nickel is used for producing alloys in coins, jewellery and stainless steel, in
electroplating as protection against corrosion, production of Raney Nickel catalyst, etc. The most commonly reported health
effect with Ni exposure is contact dermatitis, respiratory problems like chronic bronchitis, pulmonary fibrosis and impaired
lung functions which has been observed in Ni welders. The carcinogenicity of Ni has been well documented in occupationally
exposed individuals.
The purpose of this study is therefore to investigate the removal of nickel from hazardous landfill leachate using activated carbon
prepared from seeds of Delonix Regia(Binomial name), Gulmohar (Royal Poinciana) (family Fabaceae), which is a tropical or
subtropical flowering plant as a natural adsorbent.
Removal of Heavy Metal Ions from Leachate using Natural Adsorbent Delonix Regia (IJSTE/ Volume 6 / Issue 8 / 001)
All rights reserved by www.ijste.org
2
II. MATERIALS AND METHOD
Characterization of Leachate
The leachate samples were collected from Urali- Devachi, solid waste disposal site for Pune municipal area. The
characteristics study of Urali- Devachi sample is shown in Table 1. The analysis of the heavy metals in the leachate sample
was done by AAS, Chemito AA 201. Table – 1
Leachate Characteristics
Life span/ Parameter Recent Intermediate Old
Age(Years) <5 5-10 >10
pH 6.5 6.5-7.5 >7.5
COD (mg L-1) >10,000 4,000-10,000 <4,000
BOD5/COD >0.3 0.1-0.3 <0.1
Organic Compounds 80% volatile fatty acids 5-30% VFA+ Humic and Fulvic acids Humic and Fulvic acids
Ammonia Nitrogen (mg/l) <400 N.A. >400
TOC/COD <0.3 0.3-0.5 >0.5
Kjeldahl Nitrogen (g/l) 0.1-0.2 N.A. N.A.
Heavy metals Low-medium - Low
Biodegradability Important Medium Low
Table - 2
Characteristics of Leachate Sample, Urali Devachi, Pune, Maharashtra, India [5]
Sr.
No.
Sampling Station/
Parameter
Leachate
Tank
Leachate
Pond
Fresh
Leachate
Inland Surface
water
Public
Sewers
Land
Disposal
1 Appearance Turbid Turbid Turbid -- -- --
2 Color Brown Brown Brown -- -- --
3 Odor Stale Odor Stale Odor Stale Odor --- Stale Odor Stale Odor
4 BOD 3960 380 6075 30 350 100
5 COD 8240 840 15200 250 -- --
6 Total Ammoniacal
Nitrogen 20.6 7.63 880 50 50 --
7 Nitrate 18.40 12.12 18.45 -- -- --
8 Copper 0.17 0.020 0.729 3.0 3.0 --
9 Zinc 37.20 0.055 1.20 5.0 15 --
10 Chromium 0.244 0.070 0.522 2.0 2.0 --
11 Nickel 0.943 0.353 1.95 3.0 3.0 --
Characterization of DRAC
Various researchers have worked for characterization of natural adsorbents. Ahmedna and group worked for production of granular
activated carbon from agricultural by products. [24-38]
SEM micrographs have a large depth of field yielding a characteristic three dimensional appearance useful for
understanding the surface structure of a sample. SEM and EDAX were carried out on JULJSM – 6360A (Japan) and the results
are shown in Figure 1(A) and Figure 2(A) with Table 3 for Activated carbon and in Figure 1(B) and Figure 2(B) with Table 4 for
Activated carbon.
XRD for activated carbon and DRAC were carried out on Bruker AXS D8 Advanced, made in Germany and recorded from20
valves. [0º and 80º with intensity range 0º to 200º] and graphs were plotted as shown in Figure 3. FTIR was carried out
on Perkin Eimer, FT-IR system, Spectrum BX; Made in UK and following plot was obtained as shown in Figure 4 (A) and
(B). N2-BET was carried out on Micromeritics ChemiSorb 2720 instrument for powdered activated carbon and 16 mesh DRAC.
Fig. 1 (A): SEM image of Activated Carbon [JULJSM – 6360A] Fig. 2 (A): EDA of Activated Carbon[JULJSM – 6360A]
Removal of Heavy Metal Ions from Leachate using Natural Adsorbent Delonix Regia (IJSTE/ Volume 6 / Issue 8 / 001)
All rights reserved by www.ijste.org
3
Table – 4
Elemental Analysis of Activated Carbon by EDAX
Element Kev Mass% Element Kev Mass%
C K 0.277 62.26 Cl K 2.621 0.60
O K 0.525 12.77 Ca K 3.690 3.84
Mg K 1.253 0.63 Fe K 6.398 8.17
Al K 1.486 2.42 Cu K 8.040 1.24
Si K 1.739 2.85 Zr L 2.042 4.28
S K 2.307 0.94
Fig. 1: (B): SEM image of DRAC Fig. 2: (B): EDAX of Gulmohar Seed Activated Carbon
Table – 5
Elemental Analysis of GSAC by EDAX
Elements Kev Mass %
C K 0.277 60.76
O K 0.525 5.39
Cl K 2.621 11.51
K K 3.312 16.5
Cu K 8.040 2.64
Rh L 2.696 3.2
Total 100.00
Fig. 3: XRD of Activated Carbon [Insight] and DRAC
Removal of Heavy Metal Ions from Leachate using Natural Adsorbent Delonix Regia (IJSTE/ Volume 6 / Issue 8 / 001)
All rights reserved by www.ijste.org
4
Fig. 4(A): FTIR image of Activated Carbon [Perkin Elmer, Spectrum BX] Fig. 4 (B): FTIR image of Delonix Regia Seed Activated Carbon
III. EXPERIMENTAL STUDIES
Pretreatment of leachate
Pretreatment was done by heating. 250 ml of filtered sample to boiling and was then allowed to stand for 48 hrs. followed by
oxidation with 20 ml of 0.1N KMnO4. Activated Carbon from Delonix Regia Seed was prepared by treating it with
potassium hydroxide. Initially the materials were washed thoroughly with water to remove the earthy matter and dried at 1100C.
The dried material was then subjected to 1N KOH for 10 min. This material was then washed with dilute HCl to make the sample
neutral. It was then carbonized at 5000C for 25min in muffle furnace. Finally the materials were ground in an agate mortar and
particles sieved to 16 mesh size. This ground material was then impregnated with 0.1N KMnO4.
Estimation of Nickel
Nickel estimation was carried out by DMG method using Atomic Absorption Spectrophotometer, Chemito AA 201. The Beer’s
law calibration plot shows a regression of R2 =0.992 as shown in Figure 5. The concentration of Nickel in the Leachate sample
was found to be0.791667ppm.
Study of Adsorption Isotherm:
The adsorption isotherm data are important to study the adsorption capacity and equilibrium coefficient for adsorption process. In
the present work, three adsorption isotherms were utilized viz. Freundlich, Langmuir and D-R isotherm. In this study, adsorption
isotherm models were evaluated using three parameters such as temperature variation, contact time variation and also using
adsorbate concentration variation. (Kinhikar, 2012), (Kodolikar and Doss, 2019)
For the isotherm studies, varying amounts of DRAC in the range 1g to 6 g were taken in the conical flasks and added with 200
ml Leachate sample solution. The flasks were then subjected to agitation for a period of 6 hours to reach equilibrium. The
equilibrium concentration was determined by analyzing Ni +2 ions in leachate sample by UV Visible Spectrophotometer. The
Langmuir, Freundlich9and DR models were applied for adsorption equilibrium of DRAC. The results were obtained using the
equation
qe = (C0 − Ce)V
d [1]
Where qe= concentration of Ni ion on DRAC in mg/l, C0, Ce= initial and equilibrium concentrations of Ni ion in solution in
mg/l, V= volume of solution in liters, d= amount of DRAC[g]. A plot of qe against Ce is shown in Figure 6.
Fig. 5: Adsorption isotherm of Ni on DRAC
4500.0 4000 3000 2000 1500 1000 400.0
44.4
50
55
60
65
70
75
80
85
90
95.8
cm-1
%T
3011.05
2880.44
2357.99 2340.90
1539.54
1047.70
4500.0 4000 3000 2000 1500 1000 400.0
94.3
100
105
110
115
120
125
130
135
140
145
150
152.9
cm-1
%T
3721.09
3010.09
2881.30
2776.61
2355.36
2340.58
1519.74
667.41
Removal of Heavy Metal Ions from Leachate using Natural Adsorbent Delonix Regia (IJSTE/ Volume 6 / Issue 8 / 001)
All rights reserved by www.ijste.org
5
Langmuir Isotherm:
The Langmuir isotherm is applied to homogeneous sorption. It is the simplest theoretical model for monolayer adsorption which
was developed from kinetic or thermodynamic derivation. The equation for Langmuir isotherm is given below,
𝐶𝑒
𝑞𝑒= (
𝐶𝑒
𝑄) + (
1
𝑏𝑄) (2)
“Q” and “b” in this case can be determined from the plot of Ce/q versus Ce (Figure 7). “Q” indicates the maximum sorption upon
complete monolayer saturation. Higher value of “b” indicates the adsorbent has high affinity for the adsorbate and vice versa.
Fig. 6: Langmuir adsorption isotherm
Freundlich Isotherm:
It is an empirical isotherm model that considers heterogeneous adsorption and can be used for non-ideal adsorption. The equation
for Freundlich isotherm is given below,
qe = Kf ∗ Ce
1n⁄
(3)
The results revealed that the adsorption of nickel under optimum condition at 25oC obeyed Freundlich isotherm (Figure 8).This
model represents the relationship between the amount of Nickel adsorbed per unit mass of the adsorbent (qe) and concentration of
Nickel (Ce). Kf and n are constant representing the adsorption capacity and intensity of adsorption. Higher value of n indicates
greater degree of heterogeneity. For 1/n less than unity, adsorption is the predominant process that takes place otherwise desorption
becomes predominant.
Fig. 7: Freundlich Adsorption Isotherm
With the plot the slope 1/n = 1.077 which gives the value of n=0.9285 and intercept for lnkf = 3.734 giving value of constant kf
= 1.3174; hence the equation for Freundlich Adsorption Isotherm can be given for this adsorption study with DRAC is as follows:
𝑞𝑒 = 1.3174𝐶𝑒0.9285 [4]
Dubini- Radushkevich Isotherm:
The D-R isotherm which assumes a heterogeneous surface is expressed as follows
lnqe = lnqm − K ∗ e2 (5)
The parameter e can be found from equation,
e = RTln [1 +1
Ce] (6)
Where K Constant related to adsorption energy, qe is amount of Ni ions adsorbed per unit mass of adsorbent (mg/g), qm is the
maximum adsorption capacity (mg/g), Ris gas constant and T is absolute temperature.
Therefore D-R isotherm (Figure 9) can be used to predict equilibrium adsorption data at different temperatures. The model
describes the adsorption of subcritical vapors onto micro pore solids following a pore filling mechanism. The plot of ln qe vs e2
gives slope K (mol2/J2) and intercept qm.
Removal of Heavy Metal Ions from Leachate using Natural Adsorbent Delonix Regia (IJSTE/ Volume 6 / Issue 8 / 001)
All rights reserved by www.ijste.org
6
Fig. 8: Dubini - Radushkevich isotherm
With the plot the slope -K= -2E-9which gives the value of K=2E-9 and intercept for lnqm = 1.9584giving value of constant qm =
7.088; hence the equation for Dubini - Radushkevich Adsorption Isotherm can be given for this adsorption study with DRAC is as
follows:
lnqe = 1.9584 − 2−9 ∗ e2[7]
The results of all the three isotherm studies are tabulated in Table 3. Table – 6
Isotherm parameters determined with varying adsorbent dosage
Isotherm model Parameter Values
Langmuir R2 0.7377
Freundlich
Kf mg/g(L/mg)1/n
1/n
R2
1.3174
1.077
0.988
Dubini - Radushkevich R2
E (KJ/mol)
0.9355
7807
Adsorption Parameter Studies:
Effect of pH
To study the effect of pH on adsorption of DRAC in leachate, the experiments were conducted with varying pH. The
results are depicted in Figure 10.
Fig. 9: Effect of pH
Effect of Speed of Agitation
To investigate the effect of speed of Agitation on adsorption of DRAC in leachate, the experiments were conducted with
varying speed of agitation i.e.500 rpm, 800 rpm and 1000 rpm with 6g of DRAC and 100ml of leachate sample as shown in
Figure 11.
Removal of Heavy Metal Ions from Leachate using Natural Adsorbent Delonix Regia (IJSTE/ Volume 6 / Issue 8 / 001)
All rights reserved by www.ijste.org
7
Fig. 11: Effect of Speed of Agitation
Effect of Leachate Volume
To investigate the effect of leachate volume on adsorption of Ni by DRAC in leachate, the experiments were conducted with
varying leachate volume from 50 ml to 200 ml with 6g of DRAC and 800rpm. The results are as shown in Figure 12.
Fig. 12: Effect of Leachate Volume SPK
Effect of Adsorbent Dosage
To investigate the effect of adsorbent dose on adsorption of DRAC in leachate, the experiments were conducted with varying
adsorbent dosage from 0.5g to 6g. The results obtained are shown in Figure 13.
Fig. 13: Effect of Loading
Effect of Temperature
To investigate the effect of temperature on adsorption of DRAC in leachate, the experiments were conducted with adsorbent
dosage of 6g with varying temperature at 250C, 350C and 500C. The result is shown in Figure 14.
Removal of Heavy Metal Ions from Leachate using Natural Adsorbent Delonix Regia (IJSTE/ Volume 6 / Issue 8 / 001)
All rights reserved by www.ijste.org
8
Fig. 14: Effect of Temperature
Kinetic Studies:
The adsorption kinetic studies describe the solute uptake rate which in turn controls the residence time of adsorbate uptake at the
solid-liquid interface. Adsorption kinetics is one of the important characteristics in defining efficiency of adsorption process and
to understand the behavior of adsorbent.
For studying the rate of diffusion experiments were conducted with adsorbent dosage of 6g in 100 ml of leachate sample at a
temperature of 25⁰C and speed of agitation at 800 rpm for a time period of four hours. This was studied to investigate the
concentration of Ni remaining in solution vs. time on adsorption of DRAC in leachate as shown in figure 15. (Kodolikar and Doss,
2019), (Dwairiand et al, 2014), (Doss and Kodolikar, 2012), (Idrisand et al, 2012), (Sulaymon et al 2012), (Suyambu and Perumal,
2012).
Fig. 15: Kinetic studies
Pseudo-First-Order Model:
The first kinetic model considered for this study is Pseudo first order model which is expressed as:
log(qe − q) = logqe − Kf
t
2.303 (8)
q = (Co − Ce) ∗ V
M (9)
Where Co and Ce are initial and equilibrium adsorbate concentration in solution, V is volume of solution, M is mass of adsorbent
and Kf is a rate constant for pseudo-first-order model (1/min).
Fig. 16: Pseudo-first order model
Removal of Heavy Metal Ions from Leachate using Natural Adsorbent Delonix Regia (IJSTE/ Volume 6 / Issue 8 / 001)
All rights reserved by www.ijste.org
9
The figure 16 shows the result of pseudo-first order model when applied to the experimental data of adsorption.
Pseudo-Second-Order Model:
Pseudo-second order equation is based on the assumption that rate limiting step may be chemical adsorption. It is assumed that
adsorption capacity is proportional to the number of active sites occupied on the adsorbent. The equation of pseudo-second order
is given below. t
q=
q
Ks
∗ qe2 + (
1
qe
) t (10)
Where, Ks is a rate constant for pseudo second order model (g/mg.min).
The initial sorption rate, the equilibrium sorption capacity and pseudo-second order rate constant can be determined from plot
t/q vs. t [Figure 17]. As a result, the sorption system appears to follow pseudo-second order kinetics.
Fig. 17. Pseudo-second order model
The pseudo-second order model for adsorption of metal ions onto DRAC agrees well with experimental data due to greater value
of R² i.e., 0.997. These suggest that adsorption data is well represented by pseudo-second order kinetics and supports assumption
that rate limiting step of metal adsorption may be chemical adsorption.
Continuous Adsorption Column Studies:
With the batch adsorption studies data, a continuous adsorption column was designed with varying parameters and the adsorption
of Ni was studied in continuous mode at laboratory level.
(Dwairiand et al, 2014)
Preparation of Column for Adsorption Studies
An adsorption column of internal diameter of 22mm was taken and washed thoroughly with distilled water. The neck of the column
is plugged with cotton wool. DRAC of 16mesh was filled into the column up to a height of 5cm.Then, 0.1N KMnO4 was allowed
to flow through the column .After all the KMnO4 had drained the column was ready for use.
Leachate sample of known quantity is passed through the column. The outlet flow rate of column is set to 2.5ml/min. Sample
were collected from the column initially at 2min till 1hr, then at 3min for 30min, then at 4min for 40min, then at 5min for 10min,
then at 10min for 20min and lastly at 30min till the equilibrium is obtained. These samples are then analyzed using AAS. Similarly,
process was repeated for column having internal diameter of 18mm and 30mm and a bed height of 5 cm, 10 cm and 20 cm for
each.
Parameters Studied in Continuous Adsorption of Ni using DRAC
a) Break through Curve
An adsorption column of internal diameter 22mm was taken and 16mesh sieved DRAC was filled in the column up to a bed height
of 20cm. A known quantity of leachate sample was passed through the column until the equilibrium was obtained. Outlet flow rate
of column was set at 2.5ml/min. Samples were collected from the column initially at 2min till 1hr, then at 3min for 30min, then at
4min for 40min, then at 5min for 10min, then at 10min for 20min and lastly at 30min till the equilibrium are obtained. These
samples were then analyzed in AAS.
A graph of concentration vs. time representing % removal of Ni through fixed bed column (20 cm height) of DRAC (pH-8.03,
temperature:250C, initial leachate concentration of 0.791667ppm) was obtained [known as Break Through Curve] . (Figure 18)
Removal of Heavy Metal Ions from Leachate using Natural Adsorbent Delonix Regia (IJSTE/ Volume 6 / Issue 8 / 001)
All rights reserved by www.ijste.org
10
Fig. 18: Concentration against time [Break through curve] for continuous adsorption
b) Effect of Column Diameter
This study was carried out to study the adsorption of Ni ion on DRAC when the column diameter was varied as 18mm, 22mm and
30mm. This parameter gives the optimum feasible column diameter for further studies. Results of one such variation in column
diameter for constant bed height of 50mm is given in figure 19.
Fig. 19: Effect of Column Diameter with bed height 50mm
c) Effect of Bed Height
This study was carried out to study the adsorption of Ni ion on DRAC when the adsorbent bed height was varied as 50mm, 100mm
and 200mm. This parameter gives maximum the feasible bed diameter for further studies. One of the studies result with variation
in bed height for constant column diameter of 30mm is given in figure 20.
Fig. 20: Effect of Bed Height for Column diameter 30mm
A matrix study was carried out by varying column diameter and bed height and the final optimized results were obtained as
tabulated in Table 7.
Removal of Heavy Metal Ions from Leachate using Natural Adsorbent Delonix Regia (IJSTE/ Volume 6 / Issue 8 / 001)
All rights reserved by www.ijste.org
11
Table – 7
Optimum bed diameter and bed height for column
Column Diameter/Bed Height 50mm 100mm 200mm % Removal
18mm 55.5789 53.94739 60.45114
22mm 9 54.57066 73.50273
30mm 63.32238 55.34807 55.52633
The maximum removal was obtained at bed height 200mm and bed diameter of 22mm. Here the removal of Ni ions was about
73.5%. Thus for continuous process an optimum column diameter 22mm and height 200mm was obtained.
d) Effect of Flow Rate
This study was carried out to study the adsorption of Ni ion on DRAC when the flow rate was varied as2.5ml/min, 5.5ml/min and
8.5ml/min. This parameter gives maximum the feasible flow rate for further studies. The bed height and diameter of the column
was fixed as 22mm internal diameter and a bed height of 200mm. The flow rate was varied from 2.5ml/min to 5.5ml/min and
8.5ml/min and %removal were calculated.
Fig. 21: Effect of Flow Rate
IV. RESULTS AND DISCUSSION
Characterization of DRAC
Figure 3depicts the x-ray diffraction of the activated carbon obtained by calcinations of Delonix Regia at a temperature of 500°C
for a time period of 10 minutes in a muffle furnace. Inset of the same figure represents x-ray diffraction pattern of authentic
activated carbon commercially available. On comparing both the x-ray patterns, it is observed that the 2θ values of the peaks at
~ 12.2° and ~ 28.3° are in well agreement with the standard A.S.T.M data for authentic carbon. Thus, preliminary it has been
confirmed that the calcined Delonix Regia contains activated carbon which is of the grade and quality comparable to authentic
activated carbon commercially available. However, in calcined Delonix Regia pattern an additional peak at 2θ value of ~ 40.3°
is observed which can be attributed to the transformation occurring due to line broadening. This line broadening or transformation
is because of the formation of grapheme i.e. as observed in the structure of graphite. The tetrahedral structure of carbon is getting
distorted due to calcinations as one of the valencies of carbon is remaining unsatisfied. Moreover, this broadening is also
correlated with microcrystalline nature of calcined DR. due to this line broadening physical form of the activated carbon is also
changing from powder form to granular one. This granular form is amorphous in nature.
The FTIR showed characteristic peaks at around 1650 cm-1due to C=O stretch of carboxyl group and 2900 cm-1due to CH stretch
and OH stretch of hydroxyl group which confirmed presence of surface functional groups like carboxyl and hydroxyl groups
comparable to activated charcoal. BET was carried out on Micromeritics ChemiSorb 2720 instrument for powdered activated
carbon and 16 mesh DRAC and the surface area were found to be 207.839 m2/gm and 6.8865 m2/gm respectively.
Adsorption Studies
The adsorption data was validated to Freundlich and Langmuir isotherms. The R2value of 0.998 for Freundlich shows to be a better
fit than Langmuir and Dubini - Radushkevich. The adsorption equilibrium data of GSAC for removal of Ni ion were conveniently
represented by Freundlich isotherm model as with regression of R2 = 0.988.
qe = 1.3174Ce0.9285 [11]
Removal of Heavy Metal Ions from Leachate using Natural Adsorbent Delonix Regia (IJSTE/ Volume 6 / Issue 8 / 001)
All rights reserved by www.ijste.org
12
Effect of parameters
Effect of pH
To investigate the effect of pH on adsorption of DRAC in leachate, the experiments were conducted with varying pH i.e.
3.8pH, 8.03pH and 9.54pH and it was found that the pH of leachate affects its uptake of activated carbon and in general the uptake
decreases at lower as well as higher pH values. At lower pH, the uptake of Ni is less due to presence of H+ ions suppressing the
ionization of Ni so that its uptake on polar adsorbent is reduced. At higher pH range, Ni forms salt. Thus, at pH 8.03 maximum
percent removal was found. The results are depicted in Figure.
Effect of Speed of Agitation
To investigate the effect of speed of Agitation on adsorption of DRAC in leachate, the experiments were conducted with
varying speed of agitation from 500rpm, 800rpm and1000rpm with 6 gm of DRAC and 100ml of leachate sample. It was
found that with an increase in the speed of agitation, the adsorption increases. A significant increase is observed at an agitation
speed of 800rpm. Any further increase in speed of agitation did not cause a significant change in adsorption as at lower speed
of agitation the availability of the adsorption sites is comparatively less as adsorbent is coarse while with high speed
of agitation significantly high adsorption sites are available as increase in speed causes the crushing of the adsorbent. Further, it
was observed that the rate of adsorption was not found proportional to increase adsorbent surface area as per the experimental
results. In view it was justified that with increase in adsorption sites, the increase in adsorption is not proportionally high. The
maximum %removal was found to be 78.94% at 800rpm.
Effect of loading
It was found that with an increase in the dose, the adsorption increases. A significant increase is observed at adsorbent
dosage of 6gm. Any further addition of adsorbent did not cause a significant change in adsorption as at lower adsorbent
dosage the concentration of Ni in leachate sample is high as compared to availability of the adsorption sites. Further, the
rate of adsorption was not found proportional to increase in adsorbent dosage as per the experimental results. In view it was
justified that with increase in adsorbent dosage the increase in adsorption is not proportionally high. The maximum
removal was found to be at 6g of DRAC.
Effect of Temperature
To investigate the effect of temperature on adsorption of DRAC in leachate, the experiments were conducted with adsorbent dosage
of 6g with varying temperature at 250C, 350C and500C. It was observed that at 250C maximum adsorption occurred while
adsorption decreased at higher temperatures.
Kinetics Studies
The kinetics were studied to investigate the concentration of Ni remaining in solution vs. time on adsorption of DRAC in leachate.
The experiments were conducted with adsorbent dosage of 6gm, 100ml of leachate, temperature 250C, pH 8.03 and speed
of agitation800rpm and it was found that with an increase in time, the concentration decreases. A significant decrease in
concentration is observed initially and as the time increases after the equilibrium state is reached there is no significant change
in the concentration. The maximum %removal was found to be 76.47 at 6hours.
Adsorption Column Studies
From the studies made with adsorption column it can predicted that for an adsorbent capacity considered in studies % removal was
decreasing with increasing bed height at constant column diameter. But for constant bed height of the adsorbent in column as the
column diameter was increasing % removal of Ni ions was increasing. The effect of flow rate variations suggest that % removal
decreases with increase in flow rate as the load of adsorption increases on the same quantity of adsorbent in the column. The
maximum % removal of Ni [73.50%] using DRAC as adsorbent was obtained at lowest flow rate of 2.2ml/min for Column diameter
22mm and Bed height 200mm.
V. CONCLUSIONS
The characterization by XRD shows that calcined DR is microcrystalline with grapheme structure. This study shows that
Ni ion can be removed from the leachate by adsorption on DRAC. The maximum removal of 73.50% was obtained at a temperature
of 250C, pH of 8.03 using 6g of adsorbent for 100ml of leachate. The runs were carried out for 6hoursfor equilibrium studies. The
adsorption equilibrium data of DRAC for removal of Ni ion adhere to Freundlich isotherm model. The adsorption system
follows pseudo-second order kinetic model for Ni. The batch experiment showed that the adsorption of Ni ion over DRAC
is influenced by various parameters like pH, amount of adsorbent, speed of agitation, contact time and temperature. For
temperature of 250C maximum adsorption occurred while the adsorption decreased at higher temperatures. The adsorption of Ni
on DRAC proceeds through film diffusion. The adsorption studies using column quantified that the bed height 200mm, column
diameter 20mm and flow rate of 2.2ml/min give optimum % removal of Ni ions [73.50%] over DRAC in 6 hours. The DRAC can
be used as a low cost adsorbent for removal of Ni ions from the leachate solution. These parameters can be extended for
scale–up studies.
Removal of Heavy Metal Ions from Leachate using Natural Adsorbent Delonix Regia (IJSTE/ Volume 6 / Issue 8 / 001)
All rights reserved by www.ijste.org
13
NOMENCLATURE
C0, Ce= initial and equilibrium concentrations of Ni ion in solution in [mg/l]
d= amount of GSAC [g]
Kf= Freundlich Adsorption constant [unit less]
n = constant [unit less]
qe= concentration of Ni ion on GSAC in [mg/l]
V= volume of solution in [liters]
REFERENCES
[1] Adebayo F. and Aloko D., Production and characterization of activated carbon from agricultural waste (Rice-husk and Corn-cob), Journal of Engineering and Applied Sciences, 2 [2], 440-444, (2007).
[2] Ahmedna M., Marshall W. and Rao R. Production of granular activated carbons from select agricultural by-products and evaluation of their physical, chemical
and adsorption properties, Bioresource Technology, 71[2], 113-123, (2001). [3] Aji M., Gutti B. and Highina B.,Production and Characterization of Activated Carbon (AC) from Groundnut Shell and its Application in Water Treatment
University of Maiduguri, Faculty of Engineering Seminar Series, 8,91-98, (2017).
[4] Amuda O.S. and Ibrahim A.O.,Industrial waste water treatment using natural material as adsorbent,African Journal of Biotechnology, 5 (16), 1483-1487,
(2006).
[5] Aregawi B. andMangistie A., Removal of Nickel ion from aqueous solution using leaf, bark and seed of MoringaStenopetala adsorbent, Bull. Chem. Soc.
Ethiop., 27[1], 35-47, (2013). [6] Collin J, Fauziah H. and Siti F., Treatment of landfill leachate in Kayu Madang, Sabah: Porosity and adsorption studies (Part 2). Asian Chemistry Letters, 10
[3], 89-94, (2006).
[7] Daga K., Patel D. and Vyas A., Low cost adsorbent for Heavy Metal removal from Waste water: A Review, Research Journal of Chemistry and Environment, 14(1), 100-103, (2010).
[8] Doss V. and Kodolikar S.,A comparative study of 8-hydroxyquinoline-5-sulphonic acid and its 7-nitro derivative loaded on F-400 granular activated carbon
for removal of copper ions from aqueous solutions, International Journal of Environmental Sciences, 3[6], 2048-2067,(2013). [9] Doss V. and Kodolikar S.,Heavy metal adsorption by ligand loaded granular activated carbon: Thermodynamics and kinetics, International Journal of
Environmental Sciences,2[4], 2133-2149, (2012).
[10] Doss V., Kodolikar S., Kulkarni A., Katre P.and Hussinan H.,A novel route for the removal of Ni [II] from aqueous solution using nano- zero valent Ag on activated carbon, International Journal of Biological and Physical Sciences, I[4], 185-192, (2012).
[11] Dwairi R., Omar W. and Harahsheh S., Kinetic Modelling for Heavy Metal Adsorption using Jordanian Low Cost Natural Zeolite (Fixed Bed Column Study). Journal of Water Reuse and Desalination,5 (2), 231-238, (2014).
[12] Ekpete O. and Horsfall M. Preparation and Characterization of Activated Carbon derived from Fluted Pumpkin Stem Waste (Telfairiaoccidentalis Hook
F),Research Journal of Chemical Sciences,1[3], 10-17, (2011). [13] FooK.Y. and HameedB.H., An overview of landfill leachate treatment via activated carbon adsorption process, Journal of Hazardous Materials 171, 54–60,
(2009).
[14] Freeman H. Standard handbook of hazardous waste material treatment and disposal, McGraw-Hill, New York, 267, (1989). [15] Gimba M. Preparation of activated carbon from agricultural waste; cyanide binding with activated carbon matrix from coconut shell, Journal of Chemical
Society, 32, 167 – 170, (2007).
[16] Guo, Y.P, Yang, S.F, Yu, K.F, Wang, Z.C. and Xu, H.D., Adsorption of Cr (VI) on Micro- and Mesoporous Rice Husk-Based Active Carbon. Materials Chemistry and Physics Journal, 78, 132-137, (2002).
[17] Gupta V. and Sharma M., Adsorption Analysis of Cr (VI) by Natural Polymer Tamarind Kernel Powder (TKP) in aqueous Medium. Research Journal of
Chemistry and Environment, 14(1), 41-45, (2010). [18] Hendawy E.and Abdel N., Surface and adsorptive properties of carbons prepared from biomass, Applied Surface Science, 252 [2], 287-295, (2005).
[19] Huang C. Carbon Adsorption Handbook, Ann Arbor Science Publishers, Michigan, (1978).
[20] Idris S., Iyaka Y. and Umar M., Kinetic study of utilizing groundnut shell as an adsorbent in removing Chromium and Nickel ion from dye effluent, American Chemical Science Journal, 2 [1],12-24, (2012).
[21] Karthikeyan S., Sivakumar P. and Palanisamy P., Novel activated carbons from agricultural wastes and their characterization, E-Journal of Chemistry, 5 [1],
409-426, (2008). [22] Kinhikar V., Removal of Nickel ion from aqueous solution by adsorption with granular activated carbon, Research Journal of Chemical Sciences, 2[6], 6-11,
(2012).
[23] Kobya E., Demirbas M. and Oncel S., Adsorption of Nickel ions from leachate on groundnut shell activated carbon, Adsorption Science and technology, 20[2], 179-188, (2001).
[24] Kodolikar S. and Doss V., Adsorption of nickel ions from leachate on ground nut shell activated carbon, International Journal of Chemical Science, 3[1], 13-
18, (2019). [25] Metcalf J. and Eddy M. Wastewater engineering: Treatment, Disposal and Reuse, Mc-Graw Hill, New York, (1991).
[26] Mohan S. and Gandhimathi R., Removal of heavy metal ions from municipal solid waste leachate using coal fly ash as an adsorbent, Journal of Hazardous
Materials 169, 351–359, (2009). [27] Morling S., Nitrogen removal and heavy metals in leachate treatment using SBR technology, Journal of Hazardous Materials 174, 679–686, (2010).
[28] Nagwan G., Zaki, I., Khattab A., andEl-MonemN.M., Removal of some heavy metals by CKD leachate, Journal of Hazardous Materials 147,21–27, (2007).
[29] Orhan Yand Buyukgungor H., The removal of heavy metals by using agricultural waste, Water Science and Technology, 28, 247-255, (1993). [30] Patil K., Patil V., Mahajan A. and Awalekar S., Removal of Metal Ions from Waste Water using Natural Adsorbents, Journal of The Institution of Engineers,
Chemical Engg., 91, 5-9, (2011).
[31] Rajalekshmi G., Mrithaa T.., VijiChandran S. and Pandimadevi M., Preparation and Characterisation of Activated Carbon from Delonix Regia Seeds for the Removal of Methylene Blue Dye, Journal of Industrial Pollution Control, available online, (2016).
[32] RenouaS., J.G. Givaudan, S. Poulain, F. Dirassouyan, P. Moulin, Landfill leachate treatment: Review and opportunity,Journal of Hazardous Materials
150,468–493,(2008). [33] Selvi K, Pattabhi S, and Kadirvelu K, Removal of Cr (VI) from aqueous solution by adsorption on to activated carbon, Bioresour.Technol. 80, 87–89, (2001).
[34] Subramani S.E., Kumaresan D. and Thinakaran N., Application of activated carbon derived from waste Delonix Regia seed pods for the adsorption of acid
dyes: kinetic and equilibrium studies, Desalination and Water Treatment, 57:16, 7322-7333, (2016).
Removal of Heavy Metal Ions from Leachate using Natural Adsorbent Delonix Regia (IJSTE/ Volume 6 / Issue 8 / 001)
All rights reserved by www.ijste.org
14
[35] Sulaymon A., Thamer J. and Najjar J., Equilibrium and kinetic studies of adsorption of heavy metals on to activated carbon, Canadian Journal on Chemical
Engineering and Technology, 3[4],86-92, (2012). [36] Suyambu B. andPerumal R., Equilibrium, Thermodynamic and Kinetic Studies on Adsorptionof a Basic Dye by CitrullusLanatus Rind,Iranica Journal of
Energy and Environment, 3[1],23-24, (2012).
[37] Tao X and Xiaoqin L., Peanut shell activated carbon: Characterization, Surface modification and adsorption, Chinese Journal of Chemical Engineering, 16 [3], 401-406, (2008).
[38] Verla K., Horsfall M., and Ekpete O., Preparation and characterization of activated carbon from fluted pumpkin seed shell, Asian Journal of Natural &
Applied Sciences, 1[3], 39-50, (2012). [39] VijayaSaradhiB., Rao S., Prasanna KumarY., KumaraswamyK., SumalathaB., Anup K. and KalyaniG., Bisorption Studies of Heavy Metal Ion on Echinoid,
International Journal of Chemical Engineering Research, 2, 149-157, (2010).
[40] Wong K, Lee C. and Low K., Removal of Cu and Pb by tartaric acid modified rice husk from aqueous solutions, Chemosphere 50(1):23-8, (2003).
Recommended