View
9
Download
0
Category
Preview:
Citation preview
RADIO TYBOXUser guide
Wireless programmable thermostat1-zone pack or 2-zone pack
RADIO TYBOX
*2702001_rev1*
DELTA DORE - Bonnemain35270 COMBOURG - FRANCE
E-mail: deltadore@deltadore.com
Device compliant with the requirements of directives:R&TTE 1999/5/CE
Because of changes in standards and equipment, the characteristicsgiven in the text and the illustrations in this document are not bindingunless confirmed by Delta Dore.
• Carefully read these instructions prior to use.
• Do not attempt to repair the unit yourself;an after-sales service is available.
Warnings
Off mode
Absence mode
Timer mode
Automatic mode
Time setting
Programming
Set-point temperatureadjustment
Continuous mode
Modificationbuttons
Selectorknob position Selector
knob
RADIO TYBOX
Presentation
This manual is for the RADIO TYBOX transmitter.1-zone pack (1 transmitter)2-zone pack (2 transmitters)This thermostat lets you program your heating systemto Comfort or Economy mode.
Override
In automatic mode, override is used to switch fromComfort to Economy mode (or conversely) until thenext program change.
Press the override button
6:00 8:00 00:0000:00 17:0015:30 23:00
Override currently active
At 17:00, the program will return to its usual program.
To cancel the current override, press the button once more.
E.g. It is 15:30 and you would like to switch to Comfort mode before the set time (17:00).
Current day programming
Turn the knob to AUTO.
Your thermostat will function according to the program.
Automatic mode
Override
Informationbutton
Display in automatic mode
Time
Current day
Roomtemperature
Current mode
Current dayprogramming
Heatingdemand mode
NOTE: Depending on the configuration during installation, your unit will continuously display the set-point temperature or the room temperature.To change these settings, refer to the “installationguide”, or contact our customer service department or your installer.
This mode is used to choose a set-point temperature
for a given amount of time. Turn the knob to .
To make changes to the current timer mode, press OK once more.
To cancel the current timer mode, turn the knob.
Continuous mode
Choice of set-point temperature (from 5 to 30°C)
Set-pointtemperature
Confirm
Modification of the set-point temperature
This mode is used to choose a set-point temperaturethat remains constant.Turn the knob to .
Timer mode
Set-point temperature setting (from 5 to 30°C)
Confirm
Return to AUTO mode at the end of the countdown
Confirm
Adjustment of the duration from 15 minutes to 72 hours (in increments of 15 minutes)
To exit this mode, turn the knob.
This mode lets you place your home under FrostProtection if you need to leave for several days.Turn the knob to .
To make changes to the current absence mode, press OK once more.
This mode shuts down your heating system.
Turn the knob to .
Off Mode
Roomtemperature
Return to AUTO mode at the end of the countdown
Set-point temperature setting (from 5 to 15°C)
Confirm and start the calendar countdown.
Confirm
Adjustment of the number of days (1 to 365)E.g. For a departure on 1 March and a return on 16 March, program 15 days of absence.Automatic operation will resume on 16 March at midnight.
Absence mode
Turn the knob to .The days flash.
Press + or - to change the day, then press OK toconfirm and continue on to the next setting.
Repeat the operations to set the hours and minutes.
To leave the “time setting” mode, turn the knob.
Minutes
Hours
Days(1 : Monday ... 7 : Sunday)
Time setting
NOTE: If the unit is configured for a daily program, the days setting is not offered.
Set-point temperature setting
Turn the knob to .
To exit this mode, turn the knob.
Comfort set-point temperature setting (from 5 to 30°C in increments of 0.5°C)
ConfirmGo on to temperature settingEconomy
Adjustment of the Economy temperature setting (from 5 to 30°C)
Confirm
Depending on the system configuration (menu 1-08),“conf” may be displayed for the set-point temperature.This set-point temperature cannot be modified.If this is the case, the Comfort set-point temperaturecan be adjusted on your heat emitter (convector, panelheater, thermostatically controlled valve, etc.).
Press and hold until you reach 06:00
Press and hold until you reach 08:00
Press and hold until you reach 17:00
Press and hold until you reach 23:00
Press and hold until you reach 00:00
Copy and confirmor confirm
E.g. Comfort from 6:00 to 8:00 and from 17:00 to 23:006:00 8:00 00:0000:00 17:00 23:00
Programming
Turn the knob to PROG.The default program is a Comfort period from6:00 to 23:00.
1. Creating your programProgramming starts on day 1 at midnight.
Press the or buttons to create different Economyor Comfort periods.
2. Confirming and copying the programPress and hold the OK button for 3 seconds to confirmthe program you created and copy it to the next day.
3. Confirming the programPress the OK button to confirm and continue on to thenext day to program it separately.
Day
1st timeslot
Comfort periodadjustment
Economy periodadjustment
OR
Checking your program
Press the button repeatedly to check the accuracyof the Comfort and Economy periods you created.
Press OK to check the next day.
Exiting the programming mode
Turn the knob to another mode.
Programprofile
Verification of the different or periods
Time slotconsulted
NOTE: Depending on the configuration made duringinstallation, programming can be weekly or daily.Likewise, this programming may be done in incrementsof one hour, 30 minutes, or 15 minutes. To change thesesettings, refer to the “installation guide”, or contact ourcustomer service department or your installer.
• the electrical consumption in euros of the heating, water heater (DHW) and other electricalappliances (lights, household appliances, etc.).
If you have the RADIO TYWATT option on yourinstallation
• the program of the current day per zone.
Comfort periods
e.g. zone 1
Heating
Hot water production
other
• the outside temperatureWith an associated outside sensor
• total consumption of your installation
If you have the RADIO TYWATT option on your instal-lation
To reset all meters, press and hold the init. button for 5seconds.
Press repeatedly
Reset
Consumption
Press repeatedly
Open Window
E.g. With an associated door/window magnetic contact
RADIO TYBOX is on standby
RADIO TYBOX is “activated” and displays the status of the installation
Press a button
Frost Protection control
Boiler
Activating the RADIO TYBOX
With a door/window magnetic contactIf a door/window magnetic contact is associated, the heating switches to Frost protection mode if thedoor/window is opened.
The RF 640 and RF 650 receivers allows you to associate up to 8 home automation products (door/win-dow magnetic contact, alarm control centre, remotecontrols, etc.) with the RADIO TYBOX.
To associate the different products, refer to the RADIOTYBOX installation guide.
Activating the RADIO TYBOXThe receiver (RF 640 or RF 650) instantaneously takesinto account all information coming from a home automation product (e.g. an open window).
To display this information on the RADIO TYBOX, theRADIO TYBOX must be “activated” by pressing a button.
The update can take a few seconds.
Home automation features
With a TYXAL alarm control unit
If a TYXAL alarm control unit is associated.
When you activate the alarm, the heating will automatically switch to Economy mode until the nextprogram change.
When you activate the alarm, the heating will automatically switch to Economy mode until the nextprogram change.
This override can be cancelled on the RADIO TYBOX,by pressing the override button or by turning the selector knob.
With a TYXIA TransmitterWith an associated TYXIA transmitter:
- pressing the button once switches the heatingto Comfort mode until the next program change.
- pressing the button once switches the heatingto Economy mode until the next program change.
The command can be cancelled:
- on the TYXIA transmitter, by pressing ,- on the RADIO TYBOX, by pressing the override
button or by turning the selector knob.
E.g. With an associated remote control
With a TYDOM 200 remote control
From the home domain , pressing the tactile button switches off the heating.This off command is cancelled by pressing .
Pressing the tactile or button once switches theheating to Comfort or Economy mode, until the nextprogram change.The command can be cancelled:
- on the TYDOM 200 remote control, by pressing thetactile button,
- on the RADIO TYBOX, by pressing the override button or by turning the selector knob.
With a TYDOM telephone transmitterBy calling the TYDOM telephone transmitter, let thesynthesized voice guide you to determine or modify thestatus of the heating system (see the TYDOM transmitter instructions).
Home automation features
1 2 3
4 5 6
7 8 9
0 #
Separate the thermostat from its base.
Position the thermostat on its base.
Lock the thermostat.
Replace the batteries, making sure they are the right way round.
1
2
3 4
Replacing batteries
When the battery level symbol appears, you havearound 1 month to change the batteries (two 1.5 V alkaline batteries, LR03 or AAA).
The following precautions must be respected:- Ensure that the +/- polarities are correctly placed
when the battery is fitted into the unit.- Do not dispose of used batteries in unauthorized
places (you should respect the environment by takingthe batteries to a suitable collection site).
- Do not recharge the batteries.- You have approximately 30 seconds to change the
batteries before the time is reset to zero (if this happens, reset the date and time).
Battery level symbol
The programs cannot be modified and the set-point temperature settings are limited (comfort: 16 to 22°C,Economy: 13 to 19°C, Frost Protection: 5 to 11°C).Refer to the installation guide (menu 2-01) or contact your ins-taller or our customer service department.
Your heating system is in Frost-Protection mode.
The thermostat is in the , , PROG or position.
The unit displays: dEF 6.There is a communication fault between the RADIO TYBOXand the RF 640 or RF 650 receivers.Bring the transmitter nearer to the receiver.
The indication is displayed.The batteries are low.Change the batteries, making sure they are the right wayround.
The device only displays the time and the room temperature.RADIO TYBOX is in screen saver display mode, but all theheating features are running.Press a button to "activate" the display.The update can take a few seconds.
Nothing is displayed on the room unit screen.There is no power supply.Check the batteries.
The unit is in time setting mode.You took too much time in changing the batteries.Set the time. All other settings have remained unchanged.
When setting the time, there is no option to set the day.RADIO TYBOX is set to daily programming.To switch to weekly programming, refer to the installation guide(menu 1-01) or contact your installer or our customer servicedepartment.
When creating a program, the and symbols do notappear on the screen.Program changes were not authorized during installation.Refer to the installation guide (menu 2-01) or contact your ins-taller or our customer service department.
The temperature displayed does not match the temperature measured in the room (thermometer).Refer to the installation guide (menu 2-02) or contact your installer or our customer service department.
Troubleshooting
The purpose of this section is to help you quickly solvethe most common problems that you may encounterwith your product during use.If you're unsure, or if the problem persists or isn't inthis list, contact our customer service department.
During the AUTO, or modes, press the ibutton repeatedly to find out:• the room temperature or the set-point
temperature (depending on the configurationduring the installation)If your thermostat displays the temperature of the room
Information button
Set-point temperature display
Return to normal display (automatic after about 40 seconds)
The display of all information related to home automation features (outside temperature, consumptionindication, etc.) requires an “activation” phase from theRADIO TYBOX (see the home automation featuressection).
Recommended