New 04 QATRO test equipment (010914) QATRO... · 2014. 11. 6. · ♦ Sensor clamp TR-2510A : 1-10...

Preview:

Citation preview

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 1 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ALINEAR EL TEXTO A LA IZQUIERDA ELECTRICITY SPECIAL FOR … MAIN FEATURES PRIMARY PRIMARY INJECTIONS OMICRON CPC100 + CP SB1 EE-P01

    ♦ Injection of high value voltage and current for the primary test (power circuit) in all types of electrical equipment :

    → Power transformers → Current transformers → Voltage transformers → Resistances → Electrical protection equipment:

    Electromechanical → LV and HV circuit breakers → LV and HV electric motors → …

    CPC100 : ♦ 800 Aac ♦ 400 Adc ♦ 2.000 Vac ♦ 15 – 400 Hz CP SB1 (caja de conmutación) : ♦ 300 Vac ♦ 6 Adc

    DIELECTRIC STRENGTH (HIPOT) BAUR P&M VIOLA 411+047 EE-P02

    ♦ Injection of high value voltages for dielectric strength test (HIPOT : high potential) of any dry insulation, with both DC and AC voltages of very low frequency

    ♦ 40 KVac (0,01 ÷ 0,1 Hz) ♦ ± 60 KVdc (0 Hz)

    DIELECTRIC STRENGTH (HIPOT) BAUR P&M FRIDA 411+046 EE-P03

    ♦ Injection voltages high value for dielectric strength test (HIPOT: high potential) of any type of cable jacket and any dry insulation switchgear, both voltage (DC) and alternating voltage of very low frequency (VLF)

    ♦ 23 KVac (0,01 ÷ 0,1 Hz) ♦ ± 30 KVdc (0 Hz)

    HV CIRCUIT BREAKERS EUROSMC PME-500-TR + PME-TCE + PME-ATK EE-P04

    ♦ Test of high voltage circuit breakers : → Closing and opening times → Pole contact resistance → Synchronism between poles → Pole shift (Course, speed and acceleration) → Peak currents of opening and closing coils → Actuating times of closing and opening coils → Graph of closing and opening coils consumption

    ♦ 100 – 2.000 ms ♦ 0 – 50 Adc ♦ 100,0 μΩ – 1,000 Ω ♦ Course ♦ Speed ♦ Acceleration

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 2 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ELECTRICITY SPECIAL FOR … MAIN FEATURES LV ELECTRICAL INSTALLATIONS (S/ RBT 05) HT ITALIA ALLTEST AMPROBE I EE-P05

    ♦ Test of LV electrical installations, in accordance with complementary technical instructions RBT 05 "checks and inspections" (regulation of LV Spanish) :

    → Insulation resistance → Dielectric strength → Voltage drop and continuity of protective conductors (PE) → Leakage current in energy sources → Discharge time in socket power plugs → Discharge time in internal components

    ♦ Ra (MΩ) (500 Vdc) ♦ RD (HIPOT) (1,000 – 4,000 Vac) ♦ ∆U / continuity (6-12 Vac / 10-25 Aac)

    CAPACITANCE / DISSIPATION FACTOR (TAN DELTA) OMICRON CP TD1 EE-P06

    ♦ Test for the isolation status in transformers, generators, … according IEEE 62 (C51.152) and IEC 60076-1 and -3 ♦ Testing is performed at variable frequencies to better diagnose signs of ageing in insulation ♦ Tests :

    → Capacitance → Dissipation factor (tan δ) → Power factor cos φ → Power looses → Outgoing (effective power, apparent power, reactive power) → Impedance (absolute value, phase, inductance, resistance, quality)

    ♦ 12 KVac ♦ 5 Aac ♦ 8 Aac ♦ 1pF – 3 µF Tan δ : ♦ 0 – 10 % (capacitive) ♦ 0 – 100 % Cos φ : ♦ 0 – 10 % (capacitive) ♦ 0 – 100 %

    FREQUENCY RESPONSE MEGGER FRAX 101 EE-P07

    ♦ Detection of potential mechanical and electrical problems that other methods are unable to detect :

    → Winding deformations and displacements → Shorted turns and open windings → Loosened clamping structures → Broken clamping structures → Core connection problems → Partial winding collapse → Faulty core grounds → Core movements → Hoop buckling

    ♦ 0,1 Hz – 25 MHz ♦ 32.000 points ♦ 64 s – 37 s (20 Hz – 2 MHz) ♦ Points Spacing: Log., linear or both

    METAL OXIDE SURGE ARRESTER TEST ISA SCAR 10 EE-P08

    ♦ On-line diagnostic indicator of metal oxide surge arrester efficiency IEC 60099-5 A1 ED1-0 ♦ Third harmonic analysis of leakage current with compensation

    ♦ Range of total current rms and peak measures: 1.999 mA, for currents less than 1 mA, or 19.99 mA for higher currents. ♦ Third harmonic range: 199.9 µA for currents less than 1 mA, or 1999 µA for higher currents ♦ Response of the third harmonic filter:

    . < - 60 dB at 50 Hz;

    . 0 dB at 150 Hz;

    . < - 20 dB at 250 Hz and higher frequencies

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 3 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ELECTRICITY SPECIAL FOR … MAIN FEATURES HV CIRCUIT BRAKERS MEGGER TM1800 CG-19040 TM1800 + XB-51020 + XB-39130 + XB-39140 EE-P09

    ♦ Dual Ground Circuit Breaker Analyzer:

    → Timing measurements → Motion measurements → Coil currents → Dynamic resistance measurement (DRM) → Vibration analysis → DualGround™ testing

    ♦ 100 – 2.000 ms ♦ 0 – 100 Adc ♦ 500μΩ - 10 kΩ

    DIELECTRIC RESPONSE ANALYSIS AND MOISTURE IN OIL-PAPER DIELECTRICS FDS-PDC OMICRON DIRANA EE-P10

    ♦ Water analysis of oil-paper insulation ♦ Capacitance and dissipation factor measurement on power transformers ♦ Dissipation factor measurement and determination of ageing on bushings ♦ Diagnosis of generator, motor and cable insulation, as well as instrument transformers

    → Capacitance 10 pF to 100 μF → Accuracy 0,5 % + 1 pF ♦ PDC → Range, resolution 20 mA, 0,1 pA → Input resistance 10 kW → Accuracy 0,5 % ± 1 pA ♦ FDS → Voltage 200 Vpeak → Current 50 mApeak

    INSULATION / CAPACITANCE / DISSIPATION FACTOR (TAN DELTA) DOBLE M4100 + TTR EE-P11

    ♦ 12 kV Power Factor/Tan-Delta capacitance testing to assess insulation condition & dielectric loss ♦ High stress and high accuracy 10 kV TTR with the dobleTTR Capacitor ♦ Winding Leakage Reactance testing with the M4110 to detect winding deformation or damage ♦ 10 kV Single-Phase Excitation Current testing to detect degraded turn-to-turn insulation damage and magnetic circuit anomalies

    ♦ 12 kVac ♦ 3 kVac ♦ 16 A max at 110 V ♦ 10 A max at 220 V ♦ 0 to 100 μF ♦ Resolution: 0.01 pF ♦ % Tan δ: 0 to ± 999,99 %

    LEAKAGE REACTANCE DOBLE M4110 EE-P12

    ♦ Winding Leakage Reactance testing ♦ Winding deformation or damage diagnoses

    ♦ 0,1to 700 Ω ♦ 250 μH to 1,8 H ♦ 120 or 240 V at 10 A (50/60 Hz)

    SWEEP FREQUENCY RESPONSE ANALYZER (SFRA) DOBLE M5400 EE-P13

    ♦ Sweep frequency response analyzer ♦ Analyze the winding relationship inside a transformer ♦ Detect mechanical failure or movement of windings.

    ♦ Frequency response measurement : from 10 Hz to 25 MHz

    ♦ 20 Vpp at 50Ω

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 4 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ELECTRICITY SPECIAL FOR … MAIN FEATURES OLTC ANALYZER & WINDING OHMMETER DV POWER RMO100TT EE-P14

    ♦ On-load tap changer dynamic resistance measurement. ♦ Winding resistance measurement.

    ♦ Static resistance : → 5 mA – 100 A DC → up to 60 V DC → 0,1 μΩ - 2 kΩ → ± (0,1 % rdg + 0,1 % F.S.) ♦ Dynamic resistance OLTC : → Frequency range: 0,1 ms

    MICRO-OHMÍMETER MEGGER MJÖLNER 600 EE-P15

    ♦ Contact resistance measurement test ♦ DualGround™ testing

    ♦ Outputs: → 5 – 600 Adc → Max. V : 5,25 V to 600 A ♦ Range measurement : → 0 – 999.9 mΩ ♦Accuracy: → 0,1 µΩ for R< 1,0 mΩ → 1 µΩ for R< 10 mΩ → 10 µΩ for R< 100 mΩ → 100 µΩ for R< 1000 mΩ

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 5 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ELECTRICITY SPECIALS FOR … MAIN FEATURES SECONDARIES SECONDARY INJECTIONS OMICRON CMC256 PLUS EE-S01

    ♦ Injection of low value voltage and current for the secondary test (electrical protection equipment and control-command-supervision circuits) of all types of electrical equipment :

    → Electrical protection equipment: Electromechanical Analogue Digital

    → Measuring transducers → HV circuit breakers → …

    ♦ 2 x (3 x 0 - 12,5 Aac) ♦ 2 x (1 x 0 - 37,5 Aac) ♦ 2 x (1 x 0 - ± 17,5 Adc) ♦ 2 x (1 x 0 - ± 12,5 Adc) ♦ 1 x (3 x 0 - 25 Aac) ♦ 1 x (1 x 0 - 75 Aac) ♦ 1 x (1 x 0 - ± 35 Adc) ♦ 1 x (1 x 0 - ± 25 Adc) ♦ 4 x 0 - 300 Vac ♦ 1 x 0 - 600 Vac ♦ 4 x 0 - ± 300 Vdc

    SECONDARY INJECTIONS OMICRON CMC356 EE-S02

    ♦ Injection of low value voltage and current for the secondary test (protection equipment and control-command-supervision circuits) of all types of electrical equipment :

    → Electrical protection equipment: Electromechanical Analogue Digital

    → Measuring transducers → HV circuit breakers → …

    ♦ 6 x 0 - 32 Aac ♦ 3 x 0 - 64 Aac ♦ 1 x 0 - 128 Aac ♦ 1 x 0 - ± 180 Adc ♦ 4 x 0 - 300 Vac ♦ 1 x 0 - 600 Vac ♦ 4 x 0 - ± 300 Vdc

    LOG – ANALYSIS OF ELECTRIC NETWORKS (AC AND FAST VARIATION) GOSSEN / METRAWATT MAVOWATT 70 + 3 x TR-2510A (Z817A) + 3 x TR-2500A (Z817B) EE-S03

    ♦ Log – analysis of very high frequency (up to 1 μs) transient phenomena, assessment of incidents and obtaining of specific distortion and asymmetry values of the network being tested

    ♦ 4 U channels (1 – 600 Vac-dc) ♦ 4 I channels (0.1 – 6,000 Aac-dc) ♦ Fundamental wave 45-65 Hz and 15-20 Hz ♦ Network quality in accordance with UNE-EN 50160 / IEC 61000-4-30 Class A / IEEE 1159 ♦ Sensor clamp TR-2510A :

    1-10 AacRMS 40-5,000 Hz

    ♦ Sensor clamp TR-2500A : 10-500 AacRMS 40-5,000 Hz

    LOG – ANALYSIS OF ELECTRIC NETWORKS (AC AND FAST VARIATION) GOSSEN / METRAWATT MAVOWATT 30 + 3 x TR-2510A (Z817A) EE-S04

    ♦ Log – analysis of very high frequency (up to 1 μs) transient phenomena, assessment of incidents and obtaining of specific distortion and asymmetry values of the network being tested

    ♦ 4 U channels (1 – 600 Vac-dc) ♦ 4 I channels (0.1 – 6,000 Aac-dc) ♦ Fundamental wave 45-65 Hz and 15-20 Hz ♦ Network quality in accordance with UNE-EN 50160 / IEC 61000-4-30 Class A / IEEE 1159 ♦ Similar to GOSSEN / METRAWATT MAVOWATT 70 but with a few less features ♦ Sensor clamp TR-2510A :

    1-10 AacRMS 40-5,000 Hz

    THERMOGRAPHIC INFRARED CAMERA FLIR SYSTEMS T250 EE-S05

    ♦ Thermography specialised in preventive maintenance as an powerful tool of choice for searching for hot spots in electrical installations and faulty equipment ♦ Suitable for inspection of high voltage overhead power lines (76 mm telephoto lens)

    ♦ From – 20 °C to 350 °C ♦ Accuracy : ± 2 °C ♦ Lens of 24,6 / 76 mm ♦ Visual field of 25 º / 6 º ♦ 240 x 180 pixels

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 6 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ELECTRICITY SPECIALS FOR … MAIN FEATURES SECONDARIES THERMOGRAPHIC INFRARED CAMERA FLIR SYSTEMS T420 EE-S06

    ♦ Thermography specialised in preventive maintenance as an powerful tool of choice for searching for hot spots in electrical installations and faulty equipment ♦ Suitable for inspection of high voltage overhead power lines (76 mm telephoto lens)

    ♦ Lens of 24,6 / 76 mm ♦ Visual field of 25 º / 6 º ♦ From – 20 °C to + 650 °C ♦ Accuracy : ± 2 °C ♦ 320 x 240 pixels

    RECORD - ANALYSIS AC NETWORKS MEMORY HICORDER HIOKI MR8847-01 + 8966 + L9198 EE-S07

    ♦ Register - analysis of transients very high frequency (up to 20 samples / s), evaluation of incidents and obtaining specific values of distortion and asymmetry of the network under test

    ♦ 64 M-words ♦ 16 channels ♦ Accuracy 50 μV ♦ 100 mV f.s. – 400 V f.s. ♦ Frequency range 133 mHz – 8 MHz

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 7 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ELECTRICITY BASIC FOR … MAIN FEATURES INSULATION RESISTANCE + ... MEGGER MIT 1020-2

    ♦ Comprehensive test of the LV and HV dry insulation, automatic test of:

    → Insulation resistance (IR) in mode: Interruption Burn Alarm threshold

    → Polarisation index (PI) → Dielectric absorption ratio (DAR) → Step voltage (SV) → Dielectric discharge (DD)

    ♦ From 50 Vdc to 1 KVdc in 10 V step ♦ From 1 KVdc to 10 KVdc in 25 V step ♦ Measurements over 100 GΩ (three wires)

    INSULATION RESISTANCE + ... MEGGER MIT 1025

    ♦ Comprehensive test of the LV and HV dry insulation, automatic test of:

    → Insulation resistance (IR) in mode: Interruption Burn

    → Polarisation index (PI) → Dielectric absorption ratio (DAR) → Step voltage (SV) → Dielectric discharge (DD) → Ramp voltage test

    ♦ From 50 Vdc to 1 KVdc in 10 V step ♦ From 1 KVdc to 10 KVdc in 25 V step ♦ Measurements over 100 GΩ (three wires)

    INSULATION RESISTANCE GOSSEN / METRAWATT METRISO 5000A

    ♦ Manual test of insulation resistance (LV and HV dry insulation)

    ♦ 100 – 5,000 Vdc ♦ Measurements over 100 GΩ (three wires)

    INSULATION RESISTANCE E. KAINOS 4104 IN

    ♦ Manual test of insulation resistance (LV and HV dry insulation)

    ♦ 1,000 – 10,000 Vdc ♦ Measurements over 100 GΩ (three wires)

    INSULATION RESISTANCE GOSSEN / METRAWATT METRISO C

    ♦ Manual test of insulation resistance (LV dry insulation)

    ♦ 50 – 1,000 Vdc

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 8 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ELECTRICITY BASIC FOR … MAIN FEATURES PHASE ANGLES EUROSMC PME-20-CH

    ♦ Phase angle (U-U / U-I / I-I), frequency, power factor (cos φ) and for use as synchroscope measurements

    ♦ 0.2 ÷ 500 Vac ♦ 0.1 ÷ 25 Aac ♦ 40 ÷ 500 Hz

    PHASE ANGLES E. KAINOS KAINOPHI

    ♦ Phase angle (UU / UI) and power factor (cosφ) measurement

    ♦ 0.5 ÷ 400 Vac ♦ 0.2 ÷ 5 Aac ♦ 40 ÷ 60 Hz

    PHASE ANGLES, MULTIMETER AND ANALYSIS OF ELECTRIC NETWORKS ARBITER SYSTEMS + AEMC 928A + MN352

    ♦ Phase angle measurement (U-U / U-I / I-I) ♦ Power factor (cos φ) measurement ♦ Frequency measurement ♦ Active and reactive power / energy measurement ♦ Harmonics U / I and flicker by CEI 61000-4-15 ♦ Waveform display (U / I)

    ♦ 0 ÷ 360 ° o ± 180 ° ♦ ± 1.0000 pf ♦ 1 ÷ 660 Aac ♦ 0.01 ÷ 1.2 Aac ♦ 50 – 60 Hz / ± 5 Hz ♦ 0 a 99,999 MVA o MVAh ± 99,999 MVAR o MVARh ± 99,999 MW o MWh ♦ From 2nd to 50nd harmonic

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 9 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    INSTRUMENTATIÓN ESPECIAL FOR … MAIN FEATURES PRIMARY MEASUREMENTS – PRIMARY/SECONDARY INJECTIONS BEAMEX MC5 + PGXH + EXT IE-P01

    ♦ Calibration / multifunction simulation, for field (on-site), of instruments:

    → Generation / measurement of pressure → Simulation / measurement of resistance temperature (RTD) → Simulation / measurement of resistance → Simulation / measurement of thermocouple (TC) → Generation / measurement of current → Generation / measurement of voltage → Generation / measurement of low voltage → Generation / measurement of frequency → Generation / counter / of pulses → Detection of contact state (pressure switches, thermostats, ...) → Customisation of PRT temperature sensors

    ♦ Internal + external pressure modules ♦ Communication with HART® protocol instruments

    MEASUREMENTS – PRIMARY/SECONDARY INJECTIONS SCANDURA B-20 \ IS ATEX + GH1H + INERIS 03 ATEX IE-P02

    ♦ Calibration / multifunction simulation, for field (on-site) of ATEX zones, of instruments:

    → Generation / measurement of pressure → Simulation / measurement of resistance temperature (RTD) → Simulation / measurement of resistance → Simulation / measurement of thermocouple (TC) → Generation / measurement of current → Generation / measurement of voltage → Generation / measurement of low voltage → Measurement of frequency

    ♦ Internal + external pressure modules

    HEATING AND COOLING FURNACE ISOTECH FAST-CAL LOW IE-P03

    ♦ Calibration / check, for (on-site), temperature instruments:

    → Resistance temperatures (RTD) → Thermocouples

    ♦ From –35 °C to 140 °C ♦ Standard reference probe

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 10 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    INSTRUMENTATIÓN ESPECIAL FOR … MAIN FEATURES HEATING FURNACE ISOTECH FAST-CAL HIGH IE-P04

    ♦ Calibration / check, for (on-site), temperature instruments:

    → Resistance temperatures (RTD) → Thermocouples

    ♦ From +35 ºC to + 650 ºC ♦ Standard reference probe

    HEATING FURNACE ISOTECH PEGASUS IE-P05

    ♦ Calibration / check, for (on-site), temperature instruments:

    → Resistance temperatures (RTD) → Thermocouples

    ♦ From +150 ºC to + 1,200 ºC ♦ Standard reference probe

    MEASUREMENTS – PRIMARY/SECONDARY INJECTIONS BEAMEX MC6 + EXT + PGXH + PGM + PGV IE-P06

    ♦ Calibration / multifunction simulation, for field (on-site), of instruments:

    → Generation / measurement of pressure → Simulation / measurement of resistance temperature (RTD) → Simulation / measurement of resistance → Simulation / measurement of thermocouple (TC) → Generation / measurement of current → Generation / measurement of voltage → Generation / measurement of low voltage → Generation / measurement of frequency → Generation / counter / of pulses → Detection of contact state (pressure switches, thermostats, ...) → Customisation of PRT temperature sensors → Internal power supply 24 Vdc (low impedance, HART impedance or FF / PA impedance)

    ♦ Internal + external pressure modules ♦ Communication with HART® protocol instruments ♦ Communication with FIELDBUS H1 protocol instruments

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 11 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    INSTRUMENTATIÓN ESPECIALS FOR … MAIN FEATURES SECONDARY REGISTRATION - ANALYSIS OF PROCESS SIGNALS (DC AND SLOW VARIATION) GRAPHTEC MIDILOGGER GL450 IE-S01

    ♦ Log – analysis of process variables transitory phenomena (DC and slow variation) and obtaining of specific values for the instruments being tested

    ♦ 10 channels (U/I) ♦ Signals:

    20-50-100-200-500 mVdc 1-2-5-10-20-50 Vdc / 4-20 mAdc

    ♦ Sampling: 100-200-500 ms 1-2-3-4-5-10-20-30 s 1-2-5-10-20-30 m 1 h

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 12 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    DE INSTRUMENTATIÓN BÁSICS FOR … MAIN FEATURES HART PROTOCOL COMMUNICATOR MERIAM MC4150X ATEX

    ♦ Communication with instruments with HART protocol instruments for field ("in situ") ATEX zones, for configuration, commissioning and maintenance

    HART PROTOCOL COMMUNICATOR EMERSON 475 ATEX

    ♦ Communication with instruments with HART protocol instruments for field ("in situ") ATEX zones, for configuration, commissioning and maintenance

    GENERATION - MEASURING OF CURRENT GOMETRICS TINYCAL T220

    ♦ Calibration / simulation, for field (on-site), of instruments:

    → Generation / measurement of current

    ♦ Input / output: 0 to 24 mAdc

    SIMULATION – MEASUREMENT OF RESISTANCE / RESISTANCE TEMPERATURE GOMETRICS TINYCAL T240

    ♦ Calibration / simulation, for field (on-site), of instruments:

    → Simulation / measurement of resistance temperature (RTD) → Simulation / measurement of resistance

    ♦ Input / output: resistance and pt100

    GENERATION – MEASUREMENT OF THERMOCOUPLES GOMETRICS TINYCAL T250

    ♦ Calibration / simulation, for field (on-site), of instruments:

    → Generation / measurement of thermocouple (TC)

    ♦ Input / output: thermocouple J, K, T, R, S and E

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 13 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES MULTÍMETRO DIGITAL GOSSEN / METRAWATT METRAHIT TECH

    ♦ Medidas eléctricas ♦ Corriente continua : resolución 0,1 µA ♦ CAT III 1000 V y CAT IV 600 V

    DIGITAL MULTIMETER GOSSEN / METRAWATT METRAHIT PRO

    ♦ Multifunction multimeter ♦

    DIGITAL MULTIMETER + CLAMP GOSSEN / METRAWATT METRAHIT BASE + CLAMP (IN: A / OUT: V)

    ♦ Multifunction multimeter ♦

    DIGITAL MULTIMETER GOSSEN / METRAWATT METRAHIT 16S

    ♦ Multifunction multimeter ♦

    DIGITAL MULTIMETER MASTECH MY60

    ♦ Multifunction multimeter ♦ Ucc : 200 mV / 2-20-200-1.000 V ♦ Uca: 200 mV / 2-20-200-700 V ♦ Icc: 20-200 μA / 2-20-200 mA / 2-10 A ♦ Ica: 200 μA / 2-20-200 mA / 2-10 A ♦ Rcc : 200 Ω / 2-20-200 KΩ / 2-20-200 MΩ ♦ Continuidad con señal acústica ♦ Prueba de diodos y transistores

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 14 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES DIGITAL MULTIMETER MASTECH MY60

    ♦ Multifunction multimeter ♦

    DIGITAL MULTIMETER MASTECH MY980

    ♦ Multifunction multimeter ♦

    DIGITAL MULTIMETER METRIX MX22

    ♦ Multifunction multimeter ♦

    ANALOGUE MULTIMETER HIBOK 64

    ♦ Multifunction multimeter ♦

    ANALOGUE MULTIMETER METRA MAX6

    ♦ Multifunction multimeter ♦

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 15 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES ANALOGUE MULTIMETER MASTECH YX-360 TRA

    ♦ Multifunction multimeter ♦

    DIGITAL MULTIMETER GOSSEN / METRAWATT METRAHIT PRO

    ♦ Multifunction multimeter ♦

    ANALOGUE MULTIMETER STANDARD ST-303TR

    ♦ Multifunction multimeter ♦

    DIGITAL CLAMP GOSSEN / METRAWATT METRACLIP 70

    ♦ Multifunction clamp ♦

    DIGITAL CLAMP SAMWA DCM2000

    ♦ Multifunction clamp ♦

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 16 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES DIGITAL CLAMP MASTECH MS2001C

    ♦ Multifunction clamp ♦

    LEAKAGE CURRENT CLAMP FLUKE 360

    ♦ Measurement of leakage currents (to earth) of the insulation (dry, liquid and gaseous) of the electrical installations and of leakage currents (to earth) of earthed filters for electronic equipment ♦ Precision clamp meter

    ♦ Mean value detection and rms-value calibration ♦ Leakage current clamp:

    0 – 3 mAac (resolution 1 μAac) 0 – 30 mAac (resolution 10 μAac)

    ♦ Precision clamp meter: 0 – 30 Aac (resolution 0.01 Aac) 0 – 60 Aac (resolution 0.01 Aac)

    ♦ Accuracy specified at 50 ±1 Hz ♦ Frequency range 15 Hz to 150 Hz

    PHASE ROTATION INDICATOR FLUKE 9040

    ♦ Check of the: → Direct / reverse voltage sequence (UFF) → Open phase

    ♦ Sequence UFF ≡ sequence UFN ♦ U = 40 – 700 Vac ♦ 15 – 400 Hz ♦ CAT III – 600 V / CAT IV – 300 V

    DIGITAL TIMER EUROSMC PTE-30-CH

    ♦ Measurement of times of: → Actuating in protection relays → Presence or absence of signal (pulses)

    ♦ Seconds mode: 00.000 to 99,999 s ♦ Cycles mode: 0000.0 to 9,999.9 cycles ♦ Frequency mode: 20.000 to 4,000.0 Hz

    BATTERY SIMULATOR EUROSMC PTE-FCG

    ♦ Functional testing of HV equipment: → Control circuits → Command circuits → Supervision circuits → Electrical protection equipment

    especially in the absence of U voltage (VDC) system in the plant

    ♦ 48 – 125 – 250 Vdc ♦ 60 W

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 17 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES POWER SUPPLY TERMI 125V-240W

    ♦ Functional testing of HV equipment: → Control circuits → Command circuits → Supervision circuits → Electrical protection equipment → Switching of circuit breaking equipment (circuit breakers, switches, load break switches, …)

    especially in the absence of 125 Vdc voltage system in the plant

    ♦ 125 Vdc ♦ 240 W ♦ Designed by QATRO

    TACHOMETER MASTECH DT2234A

    ♦ Measurement of speed of rotating electrical machines

    ♦ 5 – 99,999 rpm

    LIGHT METER GOERZ METRAWATT MX4

    ♦ Measurement of illumination ♦ 150 – 500 – 1,500 – 5,000 lux

    WEATHER METER KESTREL AVM-4000

    ♦ Measure “in situ” of wind speed, temperature, relative humidity, dewpoint, wind chill, heat index, barometric pressure, station pressure, heat stress, date and time

    ♦ Wind Speed: 0.3 – 41 m/s 1 – 144 Km/h

    ♦ Temperature : – 29 to +70 °C ♦ Relative humidity: 5 – 95 % ♦ Barometric pressure:

    870 – 1,080 HPa / mb

    SOLAR RADIATION METER PCE SPM1

    ♦ Measurement “in situ” of solar energy and power insolation Ptot (W/m2)

    ♦ Resolution : 1 W/m2 ♦ Accuracy : ±10 W/m² or ± 5 % ♦ Spectral range: 400 – 1,100 nm ♦ Minimum, maximum and data hold functions♦ Memory : 32,000 readings

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 18 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES PHASE ROTATION INDICATOR FLUKE 9040

    ♦ Check of the: → Direct / reverse voltage sequence (UFF) → Open phase

    ♦ Sequence UFF ≡ sequence UFN ♦ U = 40 – 700 Vac ♦ 15 – 400 Hz ♦ CAT III – 600 V / CAT IV – 300 V

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 19 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    SAFETY

    PERSONAL AND NOT TRANSFERABLE FOR … MEAN FEATURES DIGITAL VOLTAGE TESTER 1 UNIT / QATRO TECHNICIAN

    ♦ All QATRO technicians have one : → Assigned personally

    ♦ Multifunction Electrical Tester

    ♦ According to our ORP management system:→ For personal safety → For the safety of others → For effectiveness – efficiency in the workplace.

    ♦ TESTBOY :

    → Uac / Udc : 6 – 1,000 V → 1,000 V / CAT IV → IP65

    ♦ FLUKE : → Uac / Udc : 12 – 690 V → 600 V / CAT IV → IP65

    TESTBOY PROFI LCD PLUS

    FLUKE T100

    DIGITAL MULTIMETER 1 UNIT / RESPONSABLE TECHNICIAN OF THE SYSTEM GOSSEN / METRAWATT METRAHIT 2+

    ♦ All QATRO technicians responsible have one:

    → Nominative, permanent and mandatory carry and use it for as long as you are on site

    ♦ Voltage tester ♦ Multimeter

    ♦ According to our ORP management system:→ For personal safety → For the safety of others

    ♦ According with our internal work procedures:

    → For measurements ♦ Basic features :

    → 600 V – CAT III → TRMS → Vac-dc : 600 mV – 600 V → Aac-dc : 60 mA – 10 A → Ω : 600 Ω – 40 MΩ → º C : – 50 – 400 → Hz : 0 – 1.000 Hz

    WALKY-TALKY 1 UNIT / QATRO TECHNICIAN KENWOOD → TK-3201 → TK-3301

    ♦ All QATRO technicians assigned to the testing and commissioning of a plant, have one :

    → Assigned personally and continuing throughout the duration of the work

    ♦ According to our ORP management system:→ For personal safety → For the safety of others → For effectiveness – efficiency in the workplace

    MEDIDOR DE DISTANCIAS POR LASER 1 UNIDAD / SERVICIO BOSCH → DLE 50

    ♦ For all QATRO services, performed in air insulated electrical installations (AIS) :

    ♦ In accordance with our H&S policy

Recommended