TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 1 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896 ALINEAR EL TEXTO A LA IZQUIERDA ELECTRICITY SPECIAL FOR … MAIN FEATURES PRIMARY PRIMARY INJECTIONS OMICRON CPC100 + CP SB1 EE-P01 Injection of high value voltage and current for the primary test (power circuit) in all types of electrical equipment : Power transformers Current transformers Voltage transformers Resistances Electrical protection equipment: Electromechanical LV and HV circuit breakers LV and HV electric motors CPC100 : 800 Aac 400 Adc 2.000 Vac 15 – 400 Hz CP SB1 (caja de conmutación) : 300 Vac 6 Adc DIELECTRIC STRENGTH (HIPOT) BAUR P&M VIOLA 411+047 EE-P02 Injection of high value voltages for dielectric strength test (HIPOT : high potential) of any dry insulation, with both DC and AC voltages of very low frequency 40 KVac (0,01 ÷ 0,1 Hz) ± 60 KVdc (0 Hz) DIELECTRIC STRENGTH (HIPOT) BAUR P&M FRIDA 411+046 EE-P03 Injection voltages high value for dielectric strength test (HIPOT: high potential) of any type of cable jacket and any dry insulation switchgear, both voltage (DC) and alternating voltage of very low frequency (VLF) 23 KVac (0,01 ÷ 0,1 Hz) ± 30 KVdc (0 Hz) HV CIRCUIT BREAKERS EUROSMC PME-500-TR + PME-TCE + PME-ATK EE-P04 Test of high voltage circuit breakers : Closing and opening times Pole contact resistance Synchronism between poles Pole shift (Course, speed and acceleration) Peak currents of opening and closing coils Actuating times of closing and opening coils Graph of closing and opening coils consumption 100 – 2.000 ms 0 – 50 Adc 100,0 μΩ – 1,000 Course Speed Acceleration

New 04 QATRO test equipment (010914) QATRO... · 2014. 11. 6. · ♦ Sensor clamp TR-2510A : 1-10 AacRMS 40-5,000 Hz ♦ Sensor clamp TR-2500A : 10-500 AacRMS 40-5,000 Hz LOG –

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 1 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ALINEAR EL TEXTO A LA IZQUIERDA ELECTRICITY SPECIAL FOR … MAIN FEATURES PRIMARY PRIMARY INJECTIONS OMICRON CPC100 + CP SB1 EE-P01

    ♦ Injection of high value voltage and current for the primary test (power circuit) in all types of electrical equipment :

    → Power transformers → Current transformers → Voltage transformers → Resistances → Electrical protection equipment:

    Electromechanical → LV and HV circuit breakers → LV and HV electric motors → …

    CPC100 : ♦ 800 Aac ♦ 400 Adc ♦ 2.000 Vac ♦ 15 – 400 Hz CP SB1 (caja de conmutación) : ♦ 300 Vac ♦ 6 Adc

    DIELECTRIC STRENGTH (HIPOT) BAUR P&M VIOLA 411+047 EE-P02

    ♦ Injection of high value voltages for dielectric strength test (HIPOT : high potential) of any dry insulation, with both DC and AC voltages of very low frequency

    ♦ 40 KVac (0,01 ÷ 0,1 Hz) ♦ ± 60 KVdc (0 Hz)

    DIELECTRIC STRENGTH (HIPOT) BAUR P&M FRIDA 411+046 EE-P03

    ♦ Injection voltages high value for dielectric strength test (HIPOT: high potential) of any type of cable jacket and any dry insulation switchgear, both voltage (DC) and alternating voltage of very low frequency (VLF)

    ♦ 23 KVac (0,01 ÷ 0,1 Hz) ♦ ± 30 KVdc (0 Hz)

    HV CIRCUIT BREAKERS EUROSMC PME-500-TR + PME-TCE + PME-ATK EE-P04

    ♦ Test of high voltage circuit breakers : → Closing and opening times → Pole contact resistance → Synchronism between poles → Pole shift (Course, speed and acceleration) → Peak currents of opening and closing coils → Actuating times of closing and opening coils → Graph of closing and opening coils consumption

    ♦ 100 – 2.000 ms ♦ 0 – 50 Adc ♦ 100,0 μΩ – 1,000 Ω ♦ Course ♦ Speed ♦ Acceleration

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 2 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ELECTRICITY SPECIAL FOR … MAIN FEATURES LV ELECTRICAL INSTALLATIONS (S/ RBT 05) HT ITALIA ALLTEST AMPROBE I EE-P05

    ♦ Test of LV electrical installations, in accordance with complementary technical instructions RBT 05 "checks and inspections" (regulation of LV Spanish) :

    → Insulation resistance → Dielectric strength → Voltage drop and continuity of protective conductors (PE) → Leakage current in energy sources → Discharge time in socket power plugs → Discharge time in internal components

    ♦ Ra (MΩ) (500 Vdc) ♦ RD (HIPOT) (1,000 – 4,000 Vac) ♦ ∆U / continuity (6-12 Vac / 10-25 Aac)

    CAPACITANCE / DISSIPATION FACTOR (TAN DELTA) OMICRON CP TD1 EE-P06

    ♦ Test for the isolation status in transformers, generators, … according IEEE 62 (C51.152) and IEC 60076-1 and -3 ♦ Testing is performed at variable frequencies to better diagnose signs of ageing in insulation ♦ Tests :

    → Capacitance → Dissipation factor (tan δ) → Power factor cos φ → Power looses → Outgoing (effective power, apparent power, reactive power) → Impedance (absolute value, phase, inductance, resistance, quality)

    ♦ 12 KVac ♦ 5 Aac ♦ 8 Aac ♦ 1pF – 3 µF Tan δ : ♦ 0 – 10 % (capacitive) ♦ 0 – 100 % Cos φ : ♦ 0 – 10 % (capacitive) ♦ 0 – 100 %

    FREQUENCY RESPONSE MEGGER FRAX 101 EE-P07

    ♦ Detection of potential mechanical and electrical problems that other methods are unable to detect :

    → Winding deformations and displacements → Shorted turns and open windings → Loosened clamping structures → Broken clamping structures → Core connection problems → Partial winding collapse → Faulty core grounds → Core movements → Hoop buckling

    ♦ 0,1 Hz – 25 MHz ♦ 32.000 points ♦ 64 s – 37 s (20 Hz – 2 MHz) ♦ Points Spacing: Log., linear or both

    METAL OXIDE SURGE ARRESTER TEST ISA SCAR 10 EE-P08

    ♦ On-line diagnostic indicator of metal oxide surge arrester efficiency IEC 60099-5 A1 ED1-0 ♦ Third harmonic analysis of leakage current with compensation

    ♦ Range of total current rms and peak measures: 1.999 mA, for currents less than 1 mA, or 19.99 mA for higher currents. ♦ Third harmonic range: 199.9 µA for currents less than 1 mA, or 1999 µA for higher currents ♦ Response of the third harmonic filter:

    . < - 60 dB at 50 Hz;

    . 0 dB at 150 Hz;

    . < - 20 dB at 250 Hz and higher frequencies

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 3 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ELECTRICITY SPECIAL FOR … MAIN FEATURES HV CIRCUIT BRAKERS MEGGER TM1800 CG-19040 TM1800 + XB-51020 + XB-39130 + XB-39140 EE-P09

    ♦ Dual Ground Circuit Breaker Analyzer:

    → Timing measurements → Motion measurements → Coil currents → Dynamic resistance measurement (DRM) → Vibration analysis → DualGround™ testing

    ♦ 100 – 2.000 ms ♦ 0 – 100 Adc ♦ 500μΩ - 10 kΩ

    DIELECTRIC RESPONSE ANALYSIS AND MOISTURE IN OIL-PAPER DIELECTRICS FDS-PDC OMICRON DIRANA EE-P10

    ♦ Water analysis of oil-paper insulation ♦ Capacitance and dissipation factor measurement on power transformers ♦ Dissipation factor measurement and determination of ageing on bushings ♦ Diagnosis of generator, motor and cable insulation, as well as instrument transformers

    → Capacitance 10 pF to 100 μF → Accuracy 0,5 % + 1 pF ♦ PDC → Range, resolution 20 mA, 0,1 pA → Input resistance 10 kW → Accuracy 0,5 % ± 1 pA ♦ FDS → Voltage 200 Vpeak → Current 50 mApeak

    INSULATION / CAPACITANCE / DISSIPATION FACTOR (TAN DELTA) DOBLE M4100 + TTR EE-P11

    ♦ 12 kV Power Factor/Tan-Delta capacitance testing to assess insulation condition & dielectric loss ♦ High stress and high accuracy 10 kV TTR with the dobleTTR Capacitor ♦ Winding Leakage Reactance testing with the M4110 to detect winding deformation or damage ♦ 10 kV Single-Phase Excitation Current testing to detect degraded turn-to-turn insulation damage and magnetic circuit anomalies

    ♦ 12 kVac ♦ 3 kVac ♦ 16 A max at 110 V ♦ 10 A max at 220 V ♦ 0 to 100 μF ♦ Resolution: 0.01 pF ♦ % Tan δ: 0 to ± 999,99 %

    LEAKAGE REACTANCE DOBLE M4110 EE-P12

    ♦ Winding Leakage Reactance testing ♦ Winding deformation or damage diagnoses

    ♦ 0,1to 700 Ω ♦ 250 μH to 1,8 H ♦ 120 or 240 V at 10 A (50/60 Hz)

    SWEEP FREQUENCY RESPONSE ANALYZER (SFRA) DOBLE M5400 EE-P13

    ♦ Sweep frequency response analyzer ♦ Analyze the winding relationship inside a transformer ♦ Detect mechanical failure or movement of windings.

    ♦ Frequency response measurement : from 10 Hz to 25 MHz

    ♦ 20 Vpp at 50Ω

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 4 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ELECTRICITY SPECIAL FOR … MAIN FEATURES OLTC ANALYZER & WINDING OHMMETER DV POWER RMO100TT EE-P14

    ♦ On-load tap changer dynamic resistance measurement. ♦ Winding resistance measurement.

    ♦ Static resistance : → 5 mA – 100 A DC → up to 60 V DC → 0,1 μΩ - 2 kΩ → ± (0,1 % rdg + 0,1 % F.S.) ♦ Dynamic resistance OLTC : → Frequency range: 0,1 ms

    MICRO-OHMÍMETER MEGGER MJÖLNER 600 EE-P15

    ♦ Contact resistance measurement test ♦ DualGround™ testing

    ♦ Outputs: → 5 – 600 Adc → Max. V : 5,25 V to 600 A ♦ Range measurement : → 0 – 999.9 mΩ ♦Accuracy: → 0,1 µΩ for R< 1,0 mΩ → 1 µΩ for R< 10 mΩ → 10 µΩ for R< 100 mΩ → 100 µΩ for R< 1000 mΩ

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 5 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ELECTRICITY SPECIALS FOR … MAIN FEATURES SECONDARIES SECONDARY INJECTIONS OMICRON CMC256 PLUS EE-S01

    ♦ Injection of low value voltage and current for the secondary test (electrical protection equipment and control-command-supervision circuits) of all types of electrical equipment :

    → Electrical protection equipment: Electromechanical Analogue Digital

    → Measuring transducers → HV circuit breakers → …

    ♦ 2 x (3 x 0 - 12,5 Aac) ♦ 2 x (1 x 0 - 37,5 Aac) ♦ 2 x (1 x 0 - ± 17,5 Adc) ♦ 2 x (1 x 0 - ± 12,5 Adc) ♦ 1 x (3 x 0 - 25 Aac) ♦ 1 x (1 x 0 - 75 Aac) ♦ 1 x (1 x 0 - ± 35 Adc) ♦ 1 x (1 x 0 - ± 25 Adc) ♦ 4 x 0 - 300 Vac ♦ 1 x 0 - 600 Vac ♦ 4 x 0 - ± 300 Vdc

    SECONDARY INJECTIONS OMICRON CMC356 EE-S02

    ♦ Injection of low value voltage and current for the secondary test (protection equipment and control-command-supervision circuits) of all types of electrical equipment :

    → Electrical protection equipment: Electromechanical Analogue Digital

    → Measuring transducers → HV circuit breakers → …

    ♦ 6 x 0 - 32 Aac ♦ 3 x 0 - 64 Aac ♦ 1 x 0 - 128 Aac ♦ 1 x 0 - ± 180 Adc ♦ 4 x 0 - 300 Vac ♦ 1 x 0 - 600 Vac ♦ 4 x 0 - ± 300 Vdc

    LOG – ANALYSIS OF ELECTRIC NETWORKS (AC AND FAST VARIATION) GOSSEN / METRAWATT MAVOWATT 70 + 3 x TR-2510A (Z817A) + 3 x TR-2500A (Z817B) EE-S03

    ♦ Log – analysis of very high frequency (up to 1 μs) transient phenomena, assessment of incidents and obtaining of specific distortion and asymmetry values of the network being tested

    ♦ 4 U channels (1 – 600 Vac-dc) ♦ 4 I channels (0.1 – 6,000 Aac-dc) ♦ Fundamental wave 45-65 Hz and 15-20 Hz ♦ Network quality in accordance with UNE-EN 50160 / IEC 61000-4-30 Class A / IEEE 1159 ♦ Sensor clamp TR-2510A :

    1-10 AacRMS 40-5,000 Hz

    ♦ Sensor clamp TR-2500A : 10-500 AacRMS 40-5,000 Hz

    LOG – ANALYSIS OF ELECTRIC NETWORKS (AC AND FAST VARIATION) GOSSEN / METRAWATT MAVOWATT 30 + 3 x TR-2510A (Z817A) EE-S04

    ♦ Log – analysis of very high frequency (up to 1 μs) transient phenomena, assessment of incidents and obtaining of specific distortion and asymmetry values of the network being tested

    ♦ 4 U channels (1 – 600 Vac-dc) ♦ 4 I channels (0.1 – 6,000 Aac-dc) ♦ Fundamental wave 45-65 Hz and 15-20 Hz ♦ Network quality in accordance with UNE-EN 50160 / IEC 61000-4-30 Class A / IEEE 1159 ♦ Similar to GOSSEN / METRAWATT MAVOWATT 70 but with a few less features ♦ Sensor clamp TR-2510A :

    1-10 AacRMS 40-5,000 Hz

    THERMOGRAPHIC INFRARED CAMERA FLIR SYSTEMS T250 EE-S05

    ♦ Thermography specialised in preventive maintenance as an powerful tool of choice for searching for hot spots in electrical installations and faulty equipment ♦ Suitable for inspection of high voltage overhead power lines (76 mm telephoto lens)

    ♦ From – 20 °C to 350 °C ♦ Accuracy : ± 2 °C ♦ Lens of 24,6 / 76 mm ♦ Visual field of 25 º / 6 º ♦ 240 x 180 pixels

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 6 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ELECTRICITY SPECIALS FOR … MAIN FEATURES SECONDARIES THERMOGRAPHIC INFRARED CAMERA FLIR SYSTEMS T420 EE-S06

    ♦ Thermography specialised in preventive maintenance as an powerful tool of choice for searching for hot spots in electrical installations and faulty equipment ♦ Suitable for inspection of high voltage overhead power lines (76 mm telephoto lens)

    ♦ Lens of 24,6 / 76 mm ♦ Visual field of 25 º / 6 º ♦ From – 20 °C to + 650 °C ♦ Accuracy : ± 2 °C ♦ 320 x 240 pixels

    RECORD - ANALYSIS AC NETWORKS MEMORY HICORDER HIOKI MR8847-01 + 8966 + L9198 EE-S07

    ♦ Register - analysis of transients very high frequency (up to 20 samples / s), evaluation of incidents and obtaining specific values of distortion and asymmetry of the network under test

    ♦ 64 M-words ♦ 16 channels ♦ Accuracy 50 μV ♦ 100 mV f.s. – 400 V f.s. ♦ Frequency range 133 mHz – 8 MHz

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 7 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ELECTRICITY BASIC FOR … MAIN FEATURES INSULATION RESISTANCE + ... MEGGER MIT 1020-2

    ♦ Comprehensive test of the LV and HV dry insulation, automatic test of:

    → Insulation resistance (IR) in mode: Interruption Burn Alarm threshold

    → Polarisation index (PI) → Dielectric absorption ratio (DAR) → Step voltage (SV) → Dielectric discharge (DD)

    ♦ From 50 Vdc to 1 KVdc in 10 V step ♦ From 1 KVdc to 10 KVdc in 25 V step ♦ Measurements over 100 GΩ (three wires)

    INSULATION RESISTANCE + ... MEGGER MIT 1025

    ♦ Comprehensive test of the LV and HV dry insulation, automatic test of:

    → Insulation resistance (IR) in mode: Interruption Burn

    → Polarisation index (PI) → Dielectric absorption ratio (DAR) → Step voltage (SV) → Dielectric discharge (DD) → Ramp voltage test

    ♦ From 50 Vdc to 1 KVdc in 10 V step ♦ From 1 KVdc to 10 KVdc in 25 V step ♦ Measurements over 100 GΩ (three wires)

    INSULATION RESISTANCE GOSSEN / METRAWATT METRISO 5000A

    ♦ Manual test of insulation resistance (LV and HV dry insulation)

    ♦ 100 – 5,000 Vdc ♦ Measurements over 100 GΩ (three wires)

    INSULATION RESISTANCE E. KAINOS 4104 IN

    ♦ Manual test of insulation resistance (LV and HV dry insulation)

    ♦ 1,000 – 10,000 Vdc ♦ Measurements over 100 GΩ (three wires)

    INSULATION RESISTANCE GOSSEN / METRAWATT METRISO C

    ♦ Manual test of insulation resistance (LV dry insulation)

    ♦ 50 – 1,000 Vdc

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 8 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    ELECTRICITY BASIC FOR … MAIN FEATURES PHASE ANGLES EUROSMC PME-20-CH

    ♦ Phase angle (U-U / U-I / I-I), frequency, power factor (cos φ) and for use as synchroscope measurements

    ♦ 0.2 ÷ 500 Vac ♦ 0.1 ÷ 25 Aac ♦ 40 ÷ 500 Hz

    PHASE ANGLES E. KAINOS KAINOPHI

    ♦ Phase angle (UU / UI) and power factor (cosφ) measurement

    ♦ 0.5 ÷ 400 Vac ♦ 0.2 ÷ 5 Aac ♦ 40 ÷ 60 Hz

    PHASE ANGLES, MULTIMETER AND ANALYSIS OF ELECTRIC NETWORKS ARBITER SYSTEMS + AEMC 928A + MN352

    ♦ Phase angle measurement (U-U / U-I / I-I) ♦ Power factor (cos φ) measurement ♦ Frequency measurement ♦ Active and reactive power / energy measurement ♦ Harmonics U / I and flicker by CEI 61000-4-15 ♦ Waveform display (U / I)

    ♦ 0 ÷ 360 ° o ± 180 ° ♦ ± 1.0000 pf ♦ 1 ÷ 660 Aac ♦ 0.01 ÷ 1.2 Aac ♦ 50 – 60 Hz / ± 5 Hz ♦ 0 a 99,999 MVA o MVAh ± 99,999 MVAR o MVARh ± 99,999 MW o MWh ♦ From 2nd to 50nd harmonic

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 9 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    INSTRUMENTATIÓN ESPECIAL FOR … MAIN FEATURES PRIMARY MEASUREMENTS – PRIMARY/SECONDARY INJECTIONS BEAMEX MC5 + PGXH + EXT IE-P01

    ♦ Calibration / multifunction simulation, for field (on-site), of instruments:

    → Generation / measurement of pressure → Simulation / measurement of resistance temperature (RTD) → Simulation / measurement of resistance → Simulation / measurement of thermocouple (TC) → Generation / measurement of current → Generation / measurement of voltage → Generation / measurement of low voltage → Generation / measurement of frequency → Generation / counter / of pulses → Detection of contact state (pressure switches, thermostats, ...) → Customisation of PRT temperature sensors

    ♦ Internal + external pressure modules ♦ Communication with HART® protocol instruments

    MEASUREMENTS – PRIMARY/SECONDARY INJECTIONS SCANDURA B-20 \ IS ATEX + GH1H + INERIS 03 ATEX IE-P02

    ♦ Calibration / multifunction simulation, for field (on-site) of ATEX zones, of instruments:

    → Generation / measurement of pressure → Simulation / measurement of resistance temperature (RTD) → Simulation / measurement of resistance → Simulation / measurement of thermocouple (TC) → Generation / measurement of current → Generation / measurement of voltage → Generation / measurement of low voltage → Measurement of frequency

    ♦ Internal + external pressure modules

    HEATING AND COOLING FURNACE ISOTECH FAST-CAL LOW IE-P03

    ♦ Calibration / check, for (on-site), temperature instruments:

    → Resistance temperatures (RTD) → Thermocouples

    ♦ From –35 °C to 140 °C ♦ Standard reference probe

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 10 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    INSTRUMENTATIÓN ESPECIAL FOR … MAIN FEATURES HEATING FURNACE ISOTECH FAST-CAL HIGH IE-P04

    ♦ Calibration / check, for (on-site), temperature instruments:

    → Resistance temperatures (RTD) → Thermocouples

    ♦ From +35 ºC to + 650 ºC ♦ Standard reference probe

    HEATING FURNACE ISOTECH PEGASUS IE-P05

    ♦ Calibration / check, for (on-site), temperature instruments:

    → Resistance temperatures (RTD) → Thermocouples

    ♦ From +150 ºC to + 1,200 ºC ♦ Standard reference probe

    MEASUREMENTS – PRIMARY/SECONDARY INJECTIONS BEAMEX MC6 + EXT + PGXH + PGM + PGV IE-P06

    ♦ Calibration / multifunction simulation, for field (on-site), of instruments:

    → Generation / measurement of pressure → Simulation / measurement of resistance temperature (RTD) → Simulation / measurement of resistance → Simulation / measurement of thermocouple (TC) → Generation / measurement of current → Generation / measurement of voltage → Generation / measurement of low voltage → Generation / measurement of frequency → Generation / counter / of pulses → Detection of contact state (pressure switches, thermostats, ...) → Customisation of PRT temperature sensors → Internal power supply 24 Vdc (low impedance, HART impedance or FF / PA impedance)

    ♦ Internal + external pressure modules ♦ Communication with HART® protocol instruments ♦ Communication with FIELDBUS H1 protocol instruments

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 11 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    INSTRUMENTATIÓN ESPECIALS FOR … MAIN FEATURES SECONDARY REGISTRATION - ANALYSIS OF PROCESS SIGNALS (DC AND SLOW VARIATION) GRAPHTEC MIDILOGGER GL450 IE-S01

    ♦ Log – analysis of process variables transitory phenomena (DC and slow variation) and obtaining of specific values for the instruments being tested

    ♦ 10 channels (U/I) ♦ Signals:

    20-50-100-200-500 mVdc 1-2-5-10-20-50 Vdc / 4-20 mAdc

    ♦ Sampling: 100-200-500 ms 1-2-3-4-5-10-20-30 s 1-2-5-10-20-30 m 1 h

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 12 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    DE INSTRUMENTATIÓN BÁSICS FOR … MAIN FEATURES HART PROTOCOL COMMUNICATOR MERIAM MC4150X ATEX

    ♦ Communication with instruments with HART protocol instruments for field ("in situ") ATEX zones, for configuration, commissioning and maintenance

    HART PROTOCOL COMMUNICATOR EMERSON 475 ATEX

    ♦ Communication with instruments with HART protocol instruments for field ("in situ") ATEX zones, for configuration, commissioning and maintenance

    GENERATION - MEASURING OF CURRENT GOMETRICS TINYCAL T220

    ♦ Calibration / simulation, for field (on-site), of instruments:

    → Generation / measurement of current

    ♦ Input / output: 0 to 24 mAdc

    SIMULATION – MEASUREMENT OF RESISTANCE / RESISTANCE TEMPERATURE GOMETRICS TINYCAL T240

    ♦ Calibration / simulation, for field (on-site), of instruments:

    → Simulation / measurement of resistance temperature (RTD) → Simulation / measurement of resistance

    ♦ Input / output: resistance and pt100

    GENERATION – MEASUREMENT OF THERMOCOUPLES GOMETRICS TINYCAL T250

    ♦ Calibration / simulation, for field (on-site), of instruments:

    → Generation / measurement of thermocouple (TC)

    ♦ Input / output: thermocouple J, K, T, R, S and E

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 13 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES MULTÍMETRO DIGITAL GOSSEN / METRAWATT METRAHIT TECH

    ♦ Medidas eléctricas ♦ Corriente continua : resolución 0,1 µA ♦ CAT III 1000 V y CAT IV 600 V

    DIGITAL MULTIMETER GOSSEN / METRAWATT METRAHIT PRO

    ♦ Multifunction multimeter ♦

    DIGITAL MULTIMETER + CLAMP GOSSEN / METRAWATT METRAHIT BASE + CLAMP (IN: A / OUT: V)

    ♦ Multifunction multimeter ♦

    DIGITAL MULTIMETER GOSSEN / METRAWATT METRAHIT 16S

    ♦ Multifunction multimeter ♦

    DIGITAL MULTIMETER MASTECH MY60

    ♦ Multifunction multimeter ♦ Ucc : 200 mV / 2-20-200-1.000 V ♦ Uca: 200 mV / 2-20-200-700 V ♦ Icc: 20-200 μA / 2-20-200 mA / 2-10 A ♦ Ica: 200 μA / 2-20-200 mA / 2-10 A ♦ Rcc : 200 Ω / 2-20-200 KΩ / 2-20-200 MΩ ♦ Continuidad con señal acústica ♦ Prueba de diodos y transistores

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 14 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES DIGITAL MULTIMETER MASTECH MY60

    ♦ Multifunction multimeter ♦

    DIGITAL MULTIMETER MASTECH MY980

    ♦ Multifunction multimeter ♦

    DIGITAL MULTIMETER METRIX MX22

    ♦ Multifunction multimeter ♦

    ANALOGUE MULTIMETER HIBOK 64

    ♦ Multifunction multimeter ♦

    ANALOGUE MULTIMETER METRA MAX6

    ♦ Multifunction multimeter ♦

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 15 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES ANALOGUE MULTIMETER MASTECH YX-360 TRA

    ♦ Multifunction multimeter ♦

    DIGITAL MULTIMETER GOSSEN / METRAWATT METRAHIT PRO

    ♦ Multifunction multimeter ♦

    ANALOGUE MULTIMETER STANDARD ST-303TR

    ♦ Multifunction multimeter ♦

    DIGITAL CLAMP GOSSEN / METRAWATT METRACLIP 70

    ♦ Multifunction clamp ♦

    DIGITAL CLAMP SAMWA DCM2000

    ♦ Multifunction clamp ♦

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 16 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES DIGITAL CLAMP MASTECH MS2001C

    ♦ Multifunction clamp ♦

    LEAKAGE CURRENT CLAMP FLUKE 360

    ♦ Measurement of leakage currents (to earth) of the insulation (dry, liquid and gaseous) of the electrical installations and of leakage currents (to earth) of earthed filters for electronic equipment ♦ Precision clamp meter

    ♦ Mean value detection and rms-value calibration ♦ Leakage current clamp:

    0 – 3 mAac (resolution 1 μAac) 0 – 30 mAac (resolution 10 μAac)

    ♦ Precision clamp meter: 0 – 30 Aac (resolution 0.01 Aac) 0 – 60 Aac (resolution 0.01 Aac)

    ♦ Accuracy specified at 50 ±1 Hz ♦ Frequency range 15 Hz to 150 Hz

    PHASE ROTATION INDICATOR FLUKE 9040

    ♦ Check of the: → Direct / reverse voltage sequence (UFF) → Open phase

    ♦ Sequence UFF ≡ sequence UFN ♦ U = 40 – 700 Vac ♦ 15 – 400 Hz ♦ CAT III – 600 V / CAT IV – 300 V

    DIGITAL TIMER EUROSMC PTE-30-CH

    ♦ Measurement of times of: → Actuating in protection relays → Presence or absence of signal (pulses)

    ♦ Seconds mode: 00.000 to 99,999 s ♦ Cycles mode: 0000.0 to 9,999.9 cycles ♦ Frequency mode: 20.000 to 4,000.0 Hz

    BATTERY SIMULATOR EUROSMC PTE-FCG

    ♦ Functional testing of HV equipment: → Control circuits → Command circuits → Supervision circuits → Electrical protection equipment

    especially in the absence of U voltage (VDC) system in the plant

    ♦ 48 – 125 – 250 Vdc ♦ 60 W

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 17 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES POWER SUPPLY TERMI 125V-240W

    ♦ Functional testing of HV equipment: → Control circuits → Command circuits → Supervision circuits → Electrical protection equipment → Switching of circuit breaking equipment (circuit breakers, switches, load break switches, …)

    especially in the absence of 125 Vdc voltage system in the plant

    ♦ 125 Vdc ♦ 240 W ♦ Designed by QATRO

    TACHOMETER MASTECH DT2234A

    ♦ Measurement of speed of rotating electrical machines

    ♦ 5 – 99,999 rpm

    LIGHT METER GOERZ METRAWATT MX4

    ♦ Measurement of illumination ♦ 150 – 500 – 1,500 – 5,000 lux

    WEATHER METER KESTREL AVM-4000

    ♦ Measure “in situ” of wind speed, temperature, relative humidity, dewpoint, wind chill, heat index, barometric pressure, station pressure, heat stress, date and time

    ♦ Wind Speed: 0.3 – 41 m/s 1 – 144 Km/h

    ♦ Temperature : – 29 to +70 °C ♦ Relative humidity: 5 – 95 % ♦ Barometric pressure:

    870 – 1,080 HPa / mb

    SOLAR RADIATION METER PCE SPM1

    ♦ Measurement “in situ” of solar energy and power insolation Ptot (W/m2)

    ♦ Resolution : 1 W/m2 ♦ Accuracy : ±10 W/m² or ± 5 % ♦ Spectral range: 400 – 1,100 nm ♦ Minimum, maximum and data hold functions♦ Memory : 32,000 readings

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 18 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES PHASE ROTATION INDICATOR FLUKE 9040

    ♦ Check of the: → Direct / reverse voltage sequence (UFF) → Open phase

    ♦ Sequence UFF ≡ sequence UFN ♦ U = 40 – 700 Vac ♦ 15 – 400 Hz ♦ CAT III – 600 V / CAT IV – 300 V

  • TEST EQUIPMENT equipment 100 % owned by qatro In most test equipment there are several units, allowing us to provide similar services in different sites simultaneous

    © QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV. 011114 HOJA 19 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos industriales S.L. : inscrita en el Registro Mercantil de A Coruña, Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número C-39.770, inscripción 1ª, C.I.F. B70077896

    SAFETY

    PERSONAL AND NOT TRANSFERABLE FOR … MEAN FEATURES DIGITAL VOLTAGE TESTER 1 UNIT / QATRO TECHNICIAN

    ♦ All QATRO technicians have one : → Assigned personally

    ♦ Multifunction Electrical Tester

    ♦ According to our ORP management system:→ For personal safety → For the safety of others → For effectiveness – efficiency in the workplace.

    ♦ TESTBOY :

    → Uac / Udc : 6 – 1,000 V → 1,000 V / CAT IV → IP65

    ♦ FLUKE : → Uac / Udc : 12 – 690 V → 600 V / CAT IV → IP65

    TESTBOY PROFI LCD PLUS

    FLUKE T100

    DIGITAL MULTIMETER 1 UNIT / RESPONSABLE TECHNICIAN OF THE SYSTEM GOSSEN / METRAWATT METRAHIT 2+

    ♦ All QATRO technicians responsible have one:

    → Nominative, permanent and mandatory carry and use it for as long as you are on site

    ♦ Voltage tester ♦ Multimeter

    ♦ According to our ORP management system:→ For personal safety → For the safety of others

    ♦ According with our internal work procedures:

    → For measurements ♦ Basic features :

    → 600 V – CAT III → TRMS → Vac-dc : 600 mV – 600 V → Aac-dc : 60 mA – 10 A → Ω : 600 Ω – 40 MΩ → º C : – 50 – 400 → Hz : 0 – 1.000 Hz

    WALKY-TALKY 1 UNIT / QATRO TECHNICIAN KENWOOD → TK-3201 → TK-3301

    ♦ All QATRO technicians assigned to the testing and commissioning of a plant, have one :

    → Assigned personally and continuing throughout the duration of the work

    ♦ According to our ORP management system:→ For personal safety → For the safety of others → For effectiveness – efficiency in the workplace

    MEDIDOR DE DISTANCIAS POR LASER 1 UNIDAD / SERVICIO BOSCH → DLE 50

    ♦ For all QATRO services, performed in air insulated electrical installations (AIS) :