View
2
Download
0
Category
Preview:
Citation preview
1/2 Te
1
Mini contactorsK 3-pole contactors for motor control, 6 and 9 AUtilisation category AC-3Control circuit : a.c.
References
a.c. control contactors (1)
- Mounting on 35 mm " rail or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.
Standard power ratings Rated Type of Instantaneous Basic reference. Weightof 3-phase motors operational connection auxiliary Complete with code50/60 Hz in category voltage contacts indicating controlAC-3 in AC-3 circuit voltage (2)
up to220 V 380 V 440/500 V 400 V230 V 415 V 660/690 VkW kW kW A N/O N/C kg1.5 2.2 3 6 Screw clamp 1 – LC1-K0610ii 0.180
– 1 LC1-K0601ii 0.180Faston 1 – LC1-K06107 ii 0.1801 x 6.35 – 1 LC1-K06017 ii 0.180or 2 x 2.8Solder pins 1 – LC1-K06105 ii 0.210for printed – 1 LC1-K06015 ii 0.210circuit board
2.2 4 4 9 Screw clamp 1 – LC1-K0910ii 0.180– 1 LC1-K0901ii 0.180
Faston 1 – LC1-K09107 ii 0.1801 x 6.35 – 1 LC1-K09017 ii 0.180or 2 x 2.8Solder pins 1 – LC1-K09105 ii 0.210for printed – 1 LC1-K09015 ii 0.210circuit board
a.c. control contactors for use in sensitive environments (1)
Recommended for use in areas sensitive to noise, high interference mains supplies, etc.
- Coil with rectifier incorporated, suppressor fitted as standard.- Mounting on 35 mm " rail or Ø 4 mm screw fixing.- Screws in the open “ready-to-tighten” position.
1.5 2.2 3 6 Screw clamp 1 – LC7-K0610ii 0.225– 1 LC7-K0601ii 0.225
Faston 1 – LC7-K06107 ii 0.2251 x 6.35 – 1 LC7-K06017 ii 0.225or 2 x 2.8Solder pins 1 – LC7-K06105 iiiiii 0.255for printed – 1 LC7-K06015 ii 0.255circuit board
2.2 4 4 9 Screw clamp 1 – LC7-K0910ii 0.225– 1 LC7-K0901ii 0.225
Faston 1 – LC7-K09107 ii 0.2251 x 6.35 – 1 LC7-K09017 ii 0.225or 2 x 2.8Solder pins 1 – LC7-K09105 ii 0.255for printed – 1 LC7-K09015 ii 0.255circuit board
(1) Add-on auxiliary contact blocks and accessories, see pages 1/8 to 1/11.(2) Standard control circuit voltages, see page opposite.
ContactorsLC1-K, LC7-K, LP1-KOn panel On mounting rail AM1-DP200 or AM1-DE200 (" 35 mm)
57
58
455731
LA1-K
58 50=
=
35
45
= =
4xØ4
ccccc
LC1-K0610ii
1/3Te
1
Mini contactorsK 3-pole contactors for motor control, 6 and 9 AUtilisation category AC-3Control circuit : d.c.
References
d.c. control contactors (1)
- Mounting on 35 mm " rail or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.
Standard power ratings Rated Type of Instantaneous Basic reference. Weightof 3-phase motors operational connection auxiliary Complete with code50/60 Hz in category voltage contacts indicating controlAC-3 in AC-3 circuit voltage (2)
up to220 V 380 V 440/500 V 400 V230 V 415 V 660/690 VkW kW kW A N/O N/C kg1.5 2.2 3 6 Screw clamp 1 – LP1-K0610ii 0.225
– 1 LP1-K0601ii 0.225Faston 1 – LP1-K06107ii 0.2251 x 6.35 – 1 LP1-K06017ii 0.225or 2 x 2.8Solder pins 1 – LP1-K06105ii 0.255for printed – 1 LP1-K06015ii 0.255circuit board
2.2 4 4 9 Screw clamp 1 – LP1-K0910ii 0.225– 1 LP1-K0901ii 0.225
Faston 1 – LP1-K09107ii 0.2251 x 6.35 – 1 LP1-K09017ii 0.225or 2 x 2.8Solder pins 1 – LP1-K09105ii 0.255for printed – 1 LP1-K09015ii 0.255circuit board
(1) Add-on auxiliary contact blocks and accessories, see pages 1/8 to 1/11.(2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre).
Contactors LC1-K (0.8…1.15 Uc) (0.85…1.1 Uc)Volts c 12 20 24 36 42 48 110 120 127 200/ 220/ 230 230/ 256 277 380/ 40050/60 Hz 208 230 240 400Code J7 Z7 B7 C7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7Volts c 400/ 440 500 575 600 660/50/60 Hz 415 690Code N7 R7 S7 SC7 X7 Y7Up to and including 240 V, coil with integral suppression device available : add 2 to the code required.Example : J72
Contactors LC7-K (0.85…1.1 Uc)Volts c 24 42 48 110 220 230/50/60 Hz 240Code B7 D7 E7 F7 M7 U7
Contactors LP1-K (0.8…1.15 Uc)Volts a 12 20 24 36 48 60 72 100 110 125 155 174 200 220 230 240 250Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPDMUD UDCoil with integral suppression device available : add 3 to the code required. Example : JD3
ContactorsLC1-K, LC7-K, LP1-KOn one asymmetrical rail DZ5-MB with clip-on mounting plateLA9-D973 DX1-AP25 On printed circuit board
57 21
50 53
45
58
8,65 = = =
10xØ1,3
A1
A2
57 27
DZ5-ME5
110
45
120
45
35= =
505
5
aaaaa
LP1-K0610iiiiiiiiii
1/4 Te
1
Mini contactorsK 3 and 4-pole contactors for heating, lighting, etc., 20 AUtilisation category AC-1Control circuit : a.c. and d.c.
References
a.c. control contactors (1)
- Mounting on 35 mm " rail or Ø 4 mm screws.- Screws in open “ready-to-tighten” position.
Non inductive Type of Number Instantaneous Basic reference. Weightloads connection of auxiliary Complete with codeCategory poles contacts indicating controlAC-1 circuit voltage (2)Maximumcurrent atθ ≤ 50 °CA N/O N/C kg
20 Screw clamp 3 – 1 – LC1-K0910ii 0.2253 – – 1 LC1-K0901ii 0.2254 – – – LC1-K09004 ii 0.1802 2 – – LC1-K09008 ii 0.180
Faston 3 – 1 – LC1-K09107 ii 0.2251 x 6.35 3 – – 1 LC1-K09017 ii 0.225or 2 x 2.8 4 – – – LC1-K090047ii 0.180
2 2 – – LC1-K090087ii 0.180Solder pins 3 – 1 – LC1-K09105 ii 0.255for printed 3 – – 1 LC1-K09015 ii 0.255circuit board 4 – – – LC1-K090045ii 0.210
2 2 – – LC1-K090085ii 0.212
a.c. control contactors for use in sensitive environments (1)
Recommended for use in areas sensitive to noise, high interference mains supplies, etc.
- Coil with rectifier incorporated, suppressor fitted as standard.- Mounting on 35 mm " rail or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.
20 Screw clamp 3 – 1 – LC7-K0910ii 0.2253 – – 1 LC7-K0901ii 0.2254 – – – LC7-K09004 ii 0.2252 2 – – LC7-K09008 ii 0.225
Faston 3 – 1 – LC7-K09107 ii 0.2251 x 6.35 3 – – 1 LC7-K09017 ii 0.225or 2 x 2.8 4 – – – LC7-K090047ii 0.225
2 2 – – LC7-K090087ii 0.225Solder pins 3 – 1 – LC7-K09105 ii 0.255for printed 3 – – 1 LC7-K09015 ii 0.255circuit board 4 – – – LC7-K090045ii 0.255
2 2 – – LC7-K090085ii 0.255
d.c. control contactors (1)
20 Screw clamp 3 – 1 – LP1-K0910ii 0.2253 – – 1 LP1-K0901ii 0.2254 – – – LP1-K09004ii 0.2252 2 – – LP1-K09008ii 0.225
Faston 3 – 1 – LP1-K09107ii 0.2251 x 6.35 3 – – 1 LP1-K09017ii 0.225or 2 x 2.8 4 – – – LP1-K090047ii 0.225
2 2 – – LP1-K090087ii 0.225Solder pins 3 – 1 – LP1-K09105ii 0.255for printed 3 – – 1 LP1-K09015ii 0.255circuit board 4 – – – LP1-K090045ii 0.255
2 2 – – LP1-K090085ii 0.255
(1) Add-on auxiliary contact blocks and accessories, see pages 1/8 to 1/11.(2) Standard control circuit voltages, see page 1/3.
ccccc
LC1-K09004ii
Dimensions :pages 1/2 and 1/3
1/5Te
1
Mini contactorsK 3-pole reversing contactors for motor control, 6 and 9 AUtilisation category AC-3Control circuit : a.c. and d.c.
References
a.c. control reversing contactors (1)
- Integral mechanical interlock.- Pre-wired power circuit connections as standard on screw clamp versions.- Mounting on 35 mm " rail or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.Standard power ratings Rated Type of Instantaneous Basic reference. Weightof 3-phase motors operational connection auxiliary Complete with code50/60 Hz in category current contacts indicating controlAC-3 in AC-3 circuit voltage (2)
up to220 V 380 V 440/500 V 400 V230 V 415 V 660/690 VkW kW kW A N/O N/C kg1.5 2.2 3 6 Screw clamp 1 – LC2-K0610ii 0.390
– 1 LC2-K0601ii 0.390Faston 1 – LC2-K06107ii 0.3701 x 6.35 – 1 LC2-K06017ii 0.370or 2 x 2.8Solder pins 1 – LC2-K06105ii 0.430for printed – 1 LC2-K06015ii 0.430circuit board
2.2 4 4 9 Screw clamp 1 – LC2-K0910ii 0.390– 1 LC2-K0901ii 0.390
Faston 1 – LC2-K09107ii 0.3701 x 6.35 – 1 LC2-K09017ii 0.370or 2 x 2.8Solder pins 1 – LC2-K09105ii 0.430for printed – 1 LC2-K09015ii 0.430circuit board
a.c. control reversing contactors for use in sensitive environments (1)
Recommended for use in areas sensitive to noise, high interference mains supplies, etc.- Coil with rectifier incorporated, suppressor fitted as standard.- Integral mechanical interlock.- Pre-wired power circuit connections as standard on screw clamp versions.- Mounting on " 35 mm rail or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.1.5 2.2 3 6 Screw clamp 1 – LC8-K0610ii 0.480
– 1 LC8-K0601ii 0.480Faston 1 – LC8-K06107ii 0.4601 x 6.35 – 1 LC8-K06017ii 0.460or 2 x 2.8Solder pins 1 – LC8-K06105ii 0.520for printed – 1 LC8-K06015ii 0.520circuit board
2.2 4 4 9 Screw clamp 1 – LC8-K0910ii 0.480– 1 LC8-K0901ii 0.480
Faston 1 – LC8-K09107ii 0.4601 x 6.35 – 1 LC8-K09017ii 0.460or 2 x 2.8Solder pins 1 – LC8-K09105ii 0.520for printed – 1 LC8-K09015ii 0.520circuit board
d.c. control reversing contactors (1)
1.5 2.2 3 6 Screw clamp 1 – LP2-K0610ii 0.480– 1 LP2-K0601ii 0.480
Faston 1 – LP2-K06107ii 0.4601 x 6.35 – 1 LP2-K06017ii 0.460or 2 x 2.8Solder pins 1 – LP2-K06105ii 0.520for printed – 1 LP2-K06015ii 0.520circuit board
2.2 4 4 9 Screw clamp 1 – LP2-K0910ii 0.480– 1 LP2-K0901ii 0.480
Faston 1 – LP2-K09107ii 0.4601 x 6.35 – 1 LP2-K09017ii 0.460or 2 x 2.8Solder pins 1 – LP2-K09105ii 0.520for printed – 1 LP2-K09015ii 0.520circuit board
(1) Auxiliary contact blocks and accessories, see pages 1/8 to 1/11.(2) Control circuit voltage codes, see page 1/7.
Dimensions :page 1/6
ccccc
LC2-K0610i ii ii ii ii i
1/6 Te
1
Mini contactorsK 3 and 4-pole changeover contactors for heating, lighting, etc., 20 AUtilisation category AC-1Control circuit : a.c.
References
a.c. control reversing contactors (1)
- Integral mechanical interlock.- Mounting on 35 mm " rail or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.
Non inductive Type of Number Instantaneous Basic reference. Weightloads connection of auxiliary Complete with codeCategory poles contacts indicating controlAC-1 circuit voltage (2)Maximumcurrent atθ ≤ 50 °CA N/O N/C kg20 Screw clamp 3 – 1 – LC2-K0910ii (3) 0.390
3 – – 1 LC2-K0901ii (3) 0.3904 – – – LC2-K09004ii 0.380
Faston 3 – 1 – LC2-K09107ii 0.3701 x 6.35 3 – – 1 LC2-K09017ii 0.370or 2 x 2.8 4 – – – LC2-K090047ii 0.370
Solder pins 3 – 1 – LC2-K09105ii 0.430for printed 3 – – 1 LC2-K09015ii 0.430circuit board 4 – – – LC2-K090045ii 0.430
a.c. control reversing contactors for use in sensitive environments (1)
Recommended for use in areas sensitive to noise, high interference mains supplies, etc.
- Coil with rectifier incorporated, suppressor fitted as standard.- Integral mechanical interlock.- Mounting on " 35 mm rail or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.20 Screw clamp 3 – 1 – LC8-K0910ii (3) 0.480
3 – – 1 LC8-K0901ii (3) 0.4804 – – – LC8-K09004ii 0.470
Faston 3 – 1 – LC8-K09107ii 0.4601 x 6.35 3 – – 1 LC8-K09017ii 0.460or 2 x 2.8 4 – – – LC8-K090047ii 0.460Solder pins 3 – 1 – LC8-K09105ii 0.520for printed 3 – – 1 LC8-K09015ii 0.520circuit board 4 – – – LC8-K090045ii 0.520
(1) Add-on auxiliary contact blocks and accessories, see pages 1/8 to 1/11.(2) Control circuit voltage codes, see page opposite.(3) Warning: this reversing contactor is pre-wired for reverse motor operation as standard.
Reversing contactorsLC2-K, LC8-K, LP2-KOn panel On mounting rail AM1-DP200 or AM1-DE200 ( " 35 mm)
5731
LA1-K
58 50=
=
90
80
8xØ4
== 57
58
90
ccccc
LC2-K0910iiiiiiiiii
1/7Te
1
Mini contactorsK 3 and 4-pole changeover contactors for heating, lighting, etc., 20 AUtilisation category AC-1Control circuit : d.c.
References
d.c. control reversing contactors (1)
- Integral mechanical interlock.- Mounting on 35 mm " rail or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.
Non inductive Type of Number Instantaneous Basic reference. Weightloads connection of auxiliary Complete with codeCategory poles contacts indicating controlAC-1 circuit voltage (2)Maximumcurrent atθ ≤ 50 °CA N/O N/C kg20 Screw clamp 3 – 1 – LP2-K0910ii (3) 0.480
3 – – 1 LP2-K09001ii (3) 0.4804 – – – LP2-K09004ii 0.480
Faston 3 – 1 – LP2-K09107ii 0.4601 x 6.35 3 – – 1 LP2-K09017ii 0.460or 2 x 2.8 4 – – – LP2-K090047ii 0.460Solder pins 3 – 1 – LP2-K09105ii 0.520for printed 3 – – 1 LP2-K09015ii 0.520circuit board 4 – – – LP2-K090045ii 0.520
(1) Add-on auxiliary contact blocks and accessories, see pages 1/8 to 1/11.(2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre).
Reversing contactors LC2-K (0.8…1.15 Uc) (0.85…1.1 Uc)Volts c 12 20 24 36 42 48 110 120 127 200/ 220/ 230 230/ 256 277 380/ 40050/60 Hz 208 230 240 400Code J7 Z7 B7 C7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7Volts c 400/ 440 500 575 600 660/50/60 Hz 415 690Code N7 R7 S7 SC7 X7 Y7Up to and including 240 V, coil with integral suppression device available : add 2 to the code required.Example : J72
Reversing contactors LC8-K (0.85…1.1 Uc)Volts c 24 42 48 110 220 230/50/60 Hz 240Code B7 D7 E7 F7 M7 U7
Reversing contactors LP2-K (0.8…1.15 Uc)Volts a 12 20 24 36 48 60 72 100 110 125 155 174 200 220 230 240 250Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UDCoil with integral suppression device available : add 3 to the code required. Example : JD3
(3) Warning: this reversing contactor is pre-wired for reverse motor operation as standard.
On one asymmetrical rail DZ5-MB with 2 clip-on mounting plates LA9-D973 or on 2 mounting plates DX1-AP25.2 x LA9-D973 2 x DX1-AP25
On printed circuit board for reversing contactors or2 contactors mounted side by side
45
58
8,65 = = =
20xØ1,3
A1
A2 50
45
8,65===
53
A1
A2
90
35= =
505
557 21
57 27
DZ5-ME5
90
110
120
aaaaa
LP2-K0910i ii ii ii ii i
1/8 Te
1
LC1,LC7,LP1-K06 ,K09
LC1,LC7,LP1-K09
LA1-KN●●P
LC1,LC7,LP1-K06 ,K09
LA1-KN●●M
LA1-KN●●
LA1-KN●●●
LA2-KT2●
1/9Te
1
Mini contactorsK 3 and 4-pole contactors, reversing and changeover contactorsInstantaneous and time delay auxiliary contacts
References
Instantaneous auxiliary contact blocks
Recommended for standard applications
Clip-on front mounting, 1 block per contactorType of connection Type of contactor Composition Reference Weight
N/O N/C kgScrew clamp LC1, LC7, LP1 2 – LA1-KN20 0.045
3 or 4-pole – 2 LA1-KN02 (1) 0.0451 1 LA1-KN11 (2) 0.0454 – LA1-KN40 0.0453 1 LA1-KN31 0.0452 2 LA1-KN22 0.0451 3 LA1-KN13 (3) 0.045– 4 LA1-KN04 (4) 0.045
Faston LC1, LC7, LP1 2 – LA1-KN207 0.0451 x 6.35 3 or 4-pole – 2 LA1-KN027 0.045or 2 x 2.8 1 1 LA1-KN117 0.045
4 – LA1-KN407 0.0453 1 LA1-KN317 0.0452 2 LA1-KN227 0.0451 3 LA1-KN137 0.045– 4 LA1-KN047 0.045
With terminal referencing conforming to standard EN 50012
Clip-on front mounting, 1 block per contactorScrew clamp LC1, LC7, LP1 – 2 LA1-KN02M 0.045
3-pole 1 1 LA1-KN11M 0.0456 and 9 A 3 1 LA1-KN31M 0.045
2 2 LA1-KN22M 0.0451 3 LA1-KN13M 0.045
LC1, LC7, LP1 1 1 LA1-KN11P 0.0454-pole 2 2 LA1-KN22P 0.0459 A
(1) Cannot be used on contactors : LP4/LP5-Kii01, LP4/LP5-K09008.(2) Cannot be used on contactors : LP4/LP5-K09008.(3) Cannot be used on contactors : LC7/LC8/LP1/LP2-K09008.(4) Cannot be used on contactors : LC7/LC8/LP1/LP2-Kii01, LC7/LC8/LP1/LP2-K09008.
Electronic time delay auxiliary contact blocks
- Relay output, with common point changeover contact, 2 A maximum.- Control voltage : c or a 24…48 V, c 110…240 V, 0.85…1.1 Uc.- Maximum switching capacity : 250 VA or 150 W.- Operating temperature : -10…+ 60 °C.- Reset time : 1.5 s during the time delay period, 0.5 s after the time delay period.
Clip-on front mounting, 1 block per contactorVoltage Type Timing Composition Reference Weight
range
V s C/O kgc or a 24…48 On-delay 1…30 1 LA2-KT2E 0.040c 110…240 On-delay 1…30 1 LA2-KT2U 0.040
Electronic time delay contact blocksLA2-KT On contactors On reversing contactors
Illustrations :page 1/8
5734
LA2-KT
58
34 38
27
5734
LA2-KT
58
LA1-KN40 i ii ii ii ii i
1/10 Te
1
Mini contactorsK 3 and 4-pole contactors, reversing and changeover contactorsSuppressor modules incorporating LED indicator
References
Mounting Type For voltages: Sold in Unit Weightand connection lots of reference kg
Clip-on fixing Varistor c and a 5 LA4-KE1B 0.010on the front of (1) 12…24 VcontactorsLC1, LC2,LP1 and LP2
c and a 5 LA4-KE1E 0.01032…48 V
c and a 5 LA4-KE1FC 0.01050…129 V
c and a 5 LA4-KE1UG 0.010130…250 V
Diode + a 5 LA4-KC1B 0.010Zener diode (2) 12…24 V
a 5 LA4-KC1E 0.01032…48 V
RC (3) c 5 LA4-KA1U 0.010220…250 V
(1) Protection by limitation of the transient voltage up to 2 Uc maximum.Maximum reduction of transient voltage peaks.Slight time delay on drop-out (1.1 to 1.5 times the normal time).(2) No overvoltage or oscillation frequency.Polarised component.Slight time delay on drop-out (1.1 to 1.5 times the normal time).(3) Protection by limitation of the transient voltage up to 3 Uc maximum and limitation of the oscillationfrequency.Slight time delay on drop-out (1.2 to 2 times the normal time).
Suppressor modulesLA4-Ki On contactors On reversing contactors
6
25
22
5722
58
5722
58
LA4-K iii
1/11Te
1
Mini contactorsK 3 and 4-pole contactors, reversing and changeover contactorsAccessories
References
Mounting and marking accessories
Description Application Sold in Unit Weightlots of reference kg
Mounting For fixing Clip-on 1 LA9-D973 0.025plates (1) on 1 ' rail
For fixing 110/120 mm 1 DX1-AP25 0.065on 2 ' rails fixing centres
Marker Clip-on Onto front of 100 LA9-D90 0.001holder contactor
Clip-in 4 maximum Strips of 25 AB1-Riiiii (2) 0.002markers per contactor 10 identical
numbers 0…9
Strips of 25 AB1-Giiiii (2) 0.00210 identicalcapitalletters A…Z
Cabling accessories
Description Application Sold in Unit Weightlots of reference kg
Paralleling For 2 poles 4 LA9-E01 0.010links with screw clamp terminals
For 4 poles 2 LA9-E02 0.015with screw clamp terminals
Set of 6 power For 3-pole For contactors 100 LA9-K0969 0.010connections reversing with screw
contactors for clamp terminalsmotor control
Set of 4 power For 4-pole For contactors 100 LA9-K0970 0.010connections changeover with screw
contactor clamp terminalspairs
(1) Order 1 mounting plate for fixing a contactor and 2 mounting plates for fixing a reversing contactor.(2) Complete the reference by replacing the iiiii with the required character.
Dimensions :pages 1/3 and 1/7
1/12 Te
1
Mini thermal overload relaysK thermal overload relays, adjustable from 0.11 to 11.5 A,for motor protection; compensated and phase failure sensitive,manual or automatic reset
References
3-pole relays with screw clamp terminals
Direct mounting : under the contactor for versions with screw clamp terminals only; pre-wired terminals,see below.Separate mounting : using terminal block LA7-K0064 (see below).On the front of the overload relay :- selection of reset mode : Manual (marked H) or Automatic (marked A),- red pushbutton : Trip Test function,- red pushbutton : Trip reset,- blue pushbutton : Stop and manual Reset,- yellow trip flag indicator : overload relay tripped.Protection by fuses or by magnetic circuit-breaker type GV2-L, see page 1/92.
Relay Fuses to be used with selected relay Reference Weightsetting Maximum ratingrange Type
aM gG (BS88)A A A kg
Class 10 A (the standard specifies a tripping time of between 2 and 10 seconds at 7.2 In)
0.11…0.16 0.25 2 LR2-K0301 0.145
0.16…0.23 0.25 2 LR2-K0302 0.145
0.23…0.36 0.5 2 LR2-K0303 0.145
0.36…0.54 1 4 LR2-K0304 0.145
0.54…0.8 1 4 LR2-K0305 0.145
0.8…1.2 2 6 LR2-K0306 0.145
1.2…1.8 2 6 LR2-K0307 0.145
1.8…2.6 4 10 LR2-K0308 0.145
2.6…3.7 4 16 LR2-K0310 0.145
3.7…5.5 6 16 LR2-K0312 0.145
5.5…8 8 20 LR2-K0314 0.145
8…11.5 10 20 LR2-K0316 0.145
LR2-KDirect mounting under the contactor
65
8
==
35= =
4xØ4
45
58
50
116
LR2-K030
1/13Te
1
Mini thermal overload relaysK thermal overload relays, adjustable from 0.11 to 11.5 A,for motor protection; compensated and phase failure sensitive,manual or automatic reset
References
Accessories for thermal overload relays
Description Type of connection Reference Weightkg
Terminal block for separate Screw clamp LA7-K0064 0.100clip-on mounting of theoverload relayon 35 mm " rail
Separate mounting with terminal block LA7-K0064on 35 mm " rail(AM1-DP200 or AM1-DE200)
AM1- CDP200 78.5DE200 86
38
80
75
c
45
1/14 Te
1
Mini contactorsK 3 and 4-pole low consumption contactorsfor motor control (AC-3) and heating and lighting, etc. (AC-1)Control circuit : d.c.
References
d.c. control contactors (1)
- Compatible with programmable controller outputs.- LED indicator incorporated.- Wide range coil (0.7…1.30 Uc), suppressor fitted as standard, consumption 1.5 W.- Mounting on 35 mm " rail or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.
Motor control Type of Instantaneous Basic reference. Weightin category AC-3 connection auxiliary Complete with codeMaximum Standard contacts indicating controlopera- power ratings circuit voltage (2)tional of 3-phasecurrent motors440 V 220 V 380 V 440/500 V
230 V 415 V 660/690 V
A kW kW kW N/O N/C kg
6 1.5 2.2 3 Screw clamp 1 – LP4-K0610iii 0.235– 1 LP4-K0601iii 0.235
Faston 1 x 6.35 1 – LP4-K06107iii 0.235or 2 x 2.8 – 1 LP4-K06017iii 0.235Solder pins 1 – LP4-K06105iii 0.265for printed – 1 LP4-K06015iii 0.265circuit board
9 2.2 4 4 Screw clamp 1 – LP4-K0910iii 0.235– 1 LP4-K0901iii 0.235
Faston 1 x 6.35 1 – LP4-K09107iii 0.235or 2 x 2.8 – 1 LP4-K09017iii 0.235Solder pins 1 – LP4-K09105iii 0.265for printed – 1 LP4-K09015iii 0.265circuit board
Non Type of Number Instantaneous Basic reference. Weightinductive connection of auxiliary Complete with codeloads poles contacts indicating controlCat. AC-1 circuit voltage (2)θ ≤ 50 °CMaximumcurrent
A N/O N/C kg
20 Screw clamp 3 – 1 – LP4-K0910iii 0.2353 – – 1 LP4-K0901iii 0.2354 – – – LP4-K09004iii 0.2352 2 – – LP4-K09008iii 0.235
Faston 1 x 6.35 3 – 1 – LP4-K09107iii 0.235or 2 x 2.8 3 – – 1 LP4-K09017iii 0.235
4 – – – LP4-K090047iii 0.2352 2 – – LP4-K090087iii 0.235
Solder pins 3 – 1 – LP4-K09105iii 0.265for printed 3 – – 1 LP4-K09015iii 0.265circuit board 4 – – – LP4-K090045iii 0.265
2 2 – – LP4-K090085iii 0.265(1) Add-on auxiliary contact blocks and accessories, see pages 1/16 and 1/17.(2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre).Volts a 12 24 48 72Code JW3 BW3 EW3 SW3
ContactorsLP4-KOn panel On mounting rail AM1-DP200 or AM1-DE200 (" 35 mm)
57
58
455731
LA1-K
58 50=
=
35
45
= =
4xØ4
aaaaa
LP4-K0610
1/15Te
1
Mini contactorsK 3 and 4-pole low consumption reversing and changeover contactorsfor motor control (AC-3) and heating, lighting etc., (AC-1)Control circuit : d.c.
References
d.c. control reversing and changeover contactors (1)
- Compatible with programmable controller outputs.- LED indicator incorporated.- Wide range coil (0.7…1.30 Uc), suppressor fitted as standard, consumption 1.5 W.- Mechanical interlock incorporated.- Pre-wired power circuit connections as standard on screw clamp versions.- Mounting on 35 mm " rail or Ø 4 mm screw fixing.- Screws in open “ready-to-tighten” position.
Motor control Type of Instantaneous Basic reference. Weightin category AC-3 connection auxiliary Complete with codeMaximum Standard contacts indicating controlopera- power ratings circuit voltage (2)tional of 3-phasecurrent motors440 V 220 V 380 V 440/500 V
230 V 415 V 660/690 V
A kW kW kW N/O N/C kg
6 1.5 2.2 3 Screw clamp 1 – LP5-K0610iii 0.490– 1 LP5-K0601iii 0.490
Faston 1 x 6.35 1 – LP5-K06107iii 0.470or 2 x 2.8 – 1 LP5-K06017iii 0.470Solder pins 1 – LP5-K06105iii 0.530for printed – 1 LP5-K06015iii 0.530circuit board
9 2.2 4 4 Screw clamp 1 – LP5-K0910iii 0.490– 1 LP5-K0901iii 0.490
Faston 1 x 6.35 1 – LP5-K09107iii 0.470or 2 x 2.8 – 1 LP5-K09017iii 0.470Solder pins 1 – LP5-K09105iii 0.530for printed – 1 LP5-K09015iii 0.530circuit board
Non Type of Number Instantaneous Basic reference. Weightinductive connection of auxiliary Complete with codeloads poles contacts indicating controlCat. AC-1 circuit voltage (2)θ ≤ 50 °CMaximumcurrent
A N/O N/C kg
20 Screw clamp 3 – 1 – LP5-K0910iii (3) 0.4903 – – 1 LP5-K0901iii (3) 0.4904 – – – LP5-K09004iii 0.490
Faston 1 x 6.35 3 – 1 – LP5-K09107iii 0.470or 2 x 2.8 3 – – 1 LP5-K09017iii 0.470
4 – – – LP5-K090047iii 0.470Solder pins 3 – 1 – LP5-K09105iii 0.530for printed 3 – – 1 LP5-K09015iii 0.530circuit board 4 – – – LP5-K090045iii 0.530
(1) Add-on auxiliary contact blocks and accessories, see pages 1/16 and 1/17.(2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre).Volts a 12 24 48 72Code JW3 BW3 EW3 SW3(3) Warning: this reversing contactor is pre-wired for reverse motor operation.
Reversing contactorsLP5-KOn panel On mounting rail AM1-DP200 or AM1-DE200 (" 35 mm)
57
58
90
50=
=
90
80
8xØ4
==5731
LA1-K
58
LP5-K0910iii
aaaaa
1/16 Te
1
Mini contactorsK 3 and 4-pole low consumption contactors,reversing and changeover contactorsInstantaneous and time delay auxiliary contacts
References
Instantaneous auxiliary contact blocks
Clip-on front mounting, 1 block per contactorType of Type of Composition Reference Weightconnection contactor
N/O N/C kg
Screw clamp 3 or 4-pole 2 – LA1-KN20 0.045– 2 LA1-KN02 0.0451 1 LA1-KN11 0.045
Faston 3 or 4-pole 2 – LA1-KN207 0.0451 x 6.35 – 2 LA1-KN027 0.045or 2 x 2.8 1 1 LA1-KN117 0.045
With terminal referencing conforming to standard EN 50012
Clip-on front mounting, 1 block per contactor
Screw clamp 3-pole, – 2 LA1-KN02M 0.0456 and 9 A 1 1 LA1-KN11M 0.045
4-pole, 9 A 1 1 LA1-KN11P 0.045
Electronic time delay auxiliary contact blocks
- Relay output, with common point changeover contact, 2 A maximum.- Control voltage : c or a 24...48 V, c 110...240 V, 0.85…1.1 Uc.- Maximum switching capacity : 250 VA or 150 W.- Operating temperature : -10…+ 60 °C.- Reset time : 1.5 s during the time delay period, 0.5 s after the time delay period.
Clip-on front mounting, 1 block per contactorVoltage Type Timing Composition Reference Weight
range
V s C/O kg
c or a 24…48 On-delay 1…30 1 LA2-KT2E 0.040
c 110…240 On-delay 1…30 1 LA2-KT2U 0.040
Electronic time delay contact blocksLA2-KT On contactor
LA2-KT2i
34 38
27
5734
LA2-KT
58
1/17Te
1
Mini contactorsK 3 and 4-pole low consumption contactors,reversing and changeover contactorsMounting, marking and cabling accessories
References
Mounting and marking accessories
Description Application Sold in Reference Weightlots of kg
Mounting For fixing Clip-on 1 LA9-D973 0.025plates (1) on 1 ' rail
For fixing 110/120 mm 1 DX1-AP25 0.065on 2 ' rails fixing centres
Marker Clip-on Onto front 100 LA9-D90 0.001holder of contactor
Clip-in 4 maximum Strips of 25 AB1-Ri (2) 0.002markers per contactor 10 identical
numbers 0…9
Strips of 25 AB1-Gi (2) 0.00210 identicalcapitalletters A…Z
Cabling accessories
Paralleling For 2 poles 4 LA9-E01 0.010links with screw clamp terminals
For 4 poles 2 LA9-E02 0.015with screw clamp terminals
Set of 6 power For 3-pole For contactors 100 LA9-K0969 0.010connections reversing with screw
contactors for clamp terminalsmotor control
Set of 4 power For 4-pole For contactors 100 LA9-K0970 0.010connections changeover with screw
contactor pairs clamp terminals
(1) Order 1 mounting plate for fixing a contactor and 2 mounting plates for fixing a reversing contactor.(2) Complete the reference by replacing the i with the required character.
On one asymmetrical rail DZ5-MB with 2 clip-on mounting plates LA9-D973 or two mounting plates DX1-AP25.2 x LA9-D973 2 x DX1-AP25
On printed circuit board for reversing contactors or2 contactors mounted side by side
45
58
8,65 = = =
20xØ1,3
A1
A2 50
45
8,65===
53
A1
A2
90
35= =
505
557 21
57 27
DZ5-ME5
90
110
120
DX1-AP25
LA9-E01
Recommended