Meta-MEC Contactors And Overload · PDF fileCheong-Ju Plant #1, Song Jung Dong, Hung Duk Ku,...

Preview:

Citation preview

GMC- 9 - 85 GMC- 100 - 800

AC 3 duty (Standard)AC 4 duty (Inching, reverse phase breaking duty)

AC 3 duty (Standard)AC 4 duty (Inching, reverse phase breaking duty)

Type lth Rated power (HP)

(A) Single phase Three phaseW/O push button With push button 115V 230V 200V 230V 460V 575V

Mechanical latch unit

GMW - 9(M) GMW - 9(M)BGMW - 12(M) GMW - 12(M)BGMW - 18(M) GMW - 18(M)BGMW - 22(M) GMW - 22(M)BGMW - 32 GMW - 32BGMW - 40 GMW - 40BGMW - 50 GMW - 50BGMW - 65 GMW - 65BGMW - 75 GMW - 75BGMW - 85 GMW - 85B

Table T4

(Metal) (Mould)

Mechanical Interlock unitType Applied contactors

AR - 9 GMC(D) - 9 ~ GMC(D) - 85AR - 100 GMC - 100 ~ GMC - 150AR - 180 GMC - 180 ~ GMC - 400AR - 600 GMC - 600 ~ GMC - 800

Table T3

Auxiliary contact

Surge absorber unitType Element Operation voltage Element spec. Applied contactorsTable T5

AS -11 AC/DC 24 ~ 48V Varistor 120VAS -12

VaristorAC/DC 100 ~ 125V Varistor 270V

GMC(D)- 9 ~ GMC - 800AS -13 AC/DC 200 ~ 240V Varistor 470VAS -14 AC 380 ~ 440V Varistor 1000VAS - 1 AC 24 ~ 48V Varistor 120V 0.1μF 100ΪAS - 2 AC 100 ~ 125V Varistor 270V 0.1μF 100Ϊ GMC - 9 ~ GMC - 85AS - 3

CRAC 200 ~ 240V Varistor 470V 0.1μF 100Ϊ

AS - 4+

DC 24 ~ 48V Varistor 120V 0.47μF 100ΪAS - 5

VaristorDC 100 ~ 125V Varistor 270V 0.47μF 100Ϊ GMD - 9 ~ GMD - 85

AS - 6 DC 200 ~ 220V Varistor 470V 0.47μF 100Ϊ

20 0.5 1 2 2 5 7.525 0.5 2 3 3 7.5 1030 1 3 5 5 10 1532 2 3 7.5 7.5 10 1545 2 5 7.5 10 20 2050 3 5 10 10 25 2570 3 7.5 10 15 30 3080 5 10 15 20 40 4090 5 15 20 25 50 50100 7.5 15 25 30 60 60

Type Applied contactors Type Applied contactorsAL - 9 GMC - 9 ~ 40 AL - 150 GMC - 150AL - 50 GMC - 50 ~ 85 AL - 220 GMC - 180, 220AL - 100 GMC - 100, 125 AL - 400 GMC - 300, 400

Type designations

The electrical lifetime Accessories

AU-1Side mount 2 pole block AU-2

Front mount 2 pole block

AU-4Front mount 4 pole block

Applying Mounting Poles Composition Typecontactors typeGM-9 to 85 type Front mount 2 pole 2NO AU-2(9 to 85A frame) 2NC

1NO+1NC4 pole 4NO AU-4

3NO+1NC2NO+2NC1NO+3NC4NC

Side mount 2 pole 1NO AU-11NC

GM-100 to 800 type Side mount 2 pole 1NO AU-100(100 to 800A frame) 1NC

Enclosed type motor starters

Lug terminal for contactors

Applying contactorsType

for 3 PoleGMC-100, 125 type

AJ125 (70821614008)(100, 125A frame)GMC-150 type

AJ150 (70821615008)(150A frame)GMC-180, 220 type

AJ220 (70821616008)(180, 220A frame)GMC-300, 400 type

AJ400 (70821617008)(300. 400A frame)GMC-600, 800 type

AJ800 (70821618008)(600. 800A frame)

AU-100Side mount 2 pole block

�� HEAD OFFICELS Tower 1026-6, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do 431-848, KoreaTel. (82-2)2034-4870Fax. (82-2)2034-4713

�� CHEONG-JU PLANTCheong-Ju Plant #1, Song Jung Dong, Hung Duk Ku,Cheong Ju, 361-720, Korea

��For your safety, please read user's manual thoroughly before operating.

��Contact the nearest authorized service facility for examination, repair, or adjustment.

��Please contact qualified service technician when you need maintenance.Do not disassemble or repair by yourself!

��Any maintenance and inspection shall be performed by the personnel having expertise concerned.Safety Instructions

��LS Industrial Systems (Middle East) FZE ����Dubai, U.A.E. Address: P.O.Box-114216, API World Tower, 303B, Sheikhe Zayed Road, Dubai, U.A.E. Tel: 971-4-332-8289 Fax: 971-4-332-9444 e-mail: hwyim@lsis.biz

��Dalian LS Industrial Systems Co., Ltd. ����Dalian, ChinaAddress: No.15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 116600, ChinaTel: 86-411-8273-7777 Fax: 86-411-8730-7560 e-mail: lixk@lsis.com.cn

��LS Industrial Systems (Wuxi) Co., Ltd. ����Wuxi, chinaAddress: 102-A , National High & New Tech Industrial Development Area, Wuxi, Jiangsu,214028, P.R.ChinaTel: 86-510-8534-6666 Fax: 86-510-522-4078 e-mail: xuhg@lsis.com.cn

��LS-VINA Industrial Systems Co., Ltd. ����Hanoi, VietnamAddress: Nguyen Khe - Dong Anh - Ha Noi - Viet NamTel: 84-4-882-0222 Fax: 84-4-882-0220 e-mail: srjo@lsisvina.com

��LS Industrial Systems Tokyo Office ����Tokyo, JapanAddress: 16FL, Higashi-Kan, Akasaka Twin Tower 17-22, 2-chome, Akasaka, Minato-ku Tokyo 107-8470, JapanTel: 81-3-3582-9128 Fax: 81-3-3582-2667 e-mail: jschuna@lsis.biz

��LS Industrial Systems Shanghai Office ����Shanghai, ChinaAddress: Room E-G, 12th Floor Huamin Empire Plaza, No.726, West Yan'an Road Shanghai 200050, P.R. ChinaTel: 86-21-5237-9977 (609) Fax: 89-21-5237-7191 e-mail: jinhk@lsis.com.cn

��LS Industrial Systems Beijing Office ����Beijing, ChinaAddress: B-Tower 17FL.Beijing Global Trade Center B/D. No.36, BeiSanHuanDong-Lu, DongCheng-District,Beijing 100013, P.R. ChinaTel: 86-10-5825-6025,7 Fax: 86-10-5825-6026 e-mail: cuixiaorong@lsis.com.cn

��LS Industrial Systems Guangzhou Office ����Guangzhou, ChinaAddress: Room 1403,14F,New Poly Tower,2 Zhongshan Liu Road,Guangzhou, P.R. ChinaTel: 86-20-8326-6764 Fax: 86-20-8326-6287 e-mail: linsz@lsis.com.cn

��LS Industrial Systems Chengdu Office ����Chengdu, ChinaAddress: 12Floor, Guodong Buiding, No52 Jindun Road Chengdu, 610041, P.R. ChinaTel: 86-28-8612-9151 Fax: 86-28-8612-9236 e-mail: yangcf@lsis.com.cn

��LS Industrial Systems Qingdao Office ����Qingdao, ChinaAddress: 7B40,Haixin Guangchang Shenye Building B, No.9, Shandong Road Qingdao 26600, P.R. ChinaTel: 86-532-8501-6568 Fax: 86-532-583-3793 e-mail: lirj@lsis.com.cnSpecifications in this catalog are subject to change without notice due to

continuous product development and improvement.

Leader in Electrics & Automation

��Global Network

2009. 01 Contactors And Overload Relays(E) 2005. 05/(16) 2009. 01 Printed in Korea STAFF

Leader in Electrics & Automation

Electric Equipment

Meta-MEC

ContactorsAnd Overload Relays

www.lsis.biz

ⓒ 2005.5 LS Industrial Systems Co.,Ltd. All rights reserved.

2-poleSide mount

4-poleFront mount

2-poleFront mount

Types AC coil GMC-9 GMC-12 GMC-18 GMC-22 DC coil GMD-9 GMD-12 GMD-18 GMD-22

Ratings / IEC60947-4 kW A kW A kW A kW AAC1 25 25 40 40AC3 200/240V 2.5 11 3.5 13 4.5 18 5.5 22

380/440V 4 9 5.5 12 7.5 18 11 22500/550V 4 7 7.5 12 7.5 13 15 22690V 4 5 7.5 9 7.5 9 15 18

Ratings / UL508 hp A hp A hp A hp Acontinuous current 20 25 30 32single phase 115V 0.5 0.5 1 2

230V 1 2 3 3three phase 200V 2 3 5 7

230V 2 3 5 7.5460V 5 7.5 10 10575V 7.5 10 15 15

NEMA size 00 00 0 0

Types AC coil GMC-9/4 GMC-12/4 GMC-18/4 GMC-22/4DC coil GMD-9/4 GMD-12/4 GMD-18/4 GMD-22/4

AC1(A) 20 20 25 32

Additional auxiliary contacts

3-pole Contactors

9AFrame size 12A 18A 22A

4-pole Contactors

Overload Relays

Bimetallic styleType GT

Base for separate mount

Setting ranges (A)

DifferentialClass10A Non-differential (3-heater)

Non-differential (2-heater)Class 20 Differential

GTK-22GTH-22/3GTH-22

GTK-22/L

0.1 - 0.160.16 - 0.250.25 - 0.4

0.4 - 0.630.63 - 1

1 - 1.61.6 - 2.52.5 - 4

4 - 65 - 86 - 97 - 109 - 13

12 - 1616 - 22

Electronic styleType GMP

Class 1��30 adjustableSeparate mount type

GMP22

Setting ranges (A)

0.1 - 1.51 - 5

4.4 - 22

GT-22

Base for separate mount

Setting ranges(A) : 16 ~ 80A

Separate mountWiring by screw

GMP80

Setting ranges(A) : 5 ~ 60A

Separate mountWiring by CT tunnelGMP60

Setting ranges (A)4 - 20

8 - 40

GMC-32 GMC-40 GMC-50 GMC-65 GMC-75 GMC-85 GMD-32 GMD-40 GMD-50 GMD-65 GMD-75 GMD-85

kW A kW A kW A kW A kW A kW A50 60 80 100 110 135

7.5 32 11 40 15 55 18.5 65 22 75 25 8515 32 18.5 40 22 50 30 65 37 75 45 85

18.5 28 22 32 30 43 33 60 37 64 45 7518.5 20 22 23 30 28 33 35 37 42 45 45hp A hp A hp A hp A hp A hp A

45 50 70 80 90 1002 3 3 5 5 7.55 5 7.5 10 15 15

7.5 10 10 15 20 2510 10 15 20 25 3020 25 30 40 50 5020 25 30 40 50 501 1 2 2 2 3

GMC-32/4 GMC-40/4 GMC-50/4 GMC-65/4 GMC-75/4 GMC-85/4 GMD-32/4 GMD-40/4 GMD-50/4 GMD-65/4 GMD-75/4 GMD-85/4

50 60 80 100 110 135

32A

Base for separate mountGT-85

Setting ranges (A)

GTK-40GTH-40/3GTH-40

GTK-40/L

GTK-85GTH-85/3GTH-85

GTK-85/L

7 - 109 - 13

12 -1816 - 2218 - 2624 - 36

28 - 4034 -5045 - 6554 - 7563 - 85

GT-40

Setting ranges (A)

4 - 65 - 86 - 97 - 109 - 13

12 -1816 - 2218 - 2624 - 3628 - 40

separate mount

40A 50A 65A 75A 85A

GMP40

2-poleSide mount

4-poleFront mount

2-poleFront mount

Types AC/DC GMC-100 GMC-125 GMC-150common coil

Ratings / IEC60947-4 kW A kW A kW A

AC1 160 160 210

AC3 200/240V 30 105 37 125 45 150

380/440V 55 105 60 120 75 150

500/550V 55 85 60 90 90 140

690V 55 65 60 70 90 100

Ratings / UL508 hp A hp A hp A

continuous current 160 160 210

single phase 115V 7.5 10 15

230V 15 20 25

three phase 200V 30 40 40

230V 30 40 50

460V 60 75 100

575V 60 75 100

NEMA size 3 3 4

Types AC/DC GMC-100/4 GMC-125/4 GMC-150/4common coil

AC1(A) 160 160 210

Additional auxiliary contacts

3-pole Contactors

100AFrame size 125A 150A

4-pole Contactors

Overload Relays

Bimetallic styleType GT

GT- 100

Setting ranges (A)

Differential

Class10A Non-differential (3-heater)

Non-differential (2-heater)

Class 20 Differential

GTK-100

GTH-100/3

GTH-100

GTK-100/L

GTK-150

GTH-150/3

GTH-150

GTK-150/L

34 - 50

39 - 57

43 - 65

54 - 80

65 - 100

85 - 125 GT- 150

Setting ranges (A)

34 - 50

39 - 57

43 - 65

54 - 80

65 - 100

85 - 125

100 - 150

AU-1001NO+1NC, Side mount

GTK-220

GTH-220/3

GTH-220

GTK-220/L

GTK-400

GTH-400/3

GTH-400

GTK-400/L

GTK-600

GTH-600/3

GTH-600

GTK-600/L

GMC-180 GMC-220 GMC-300 GMC-400 GMC-600 GMC-800

kW A kW A kW A kW A kW A kW A

230 275 350 450 660 900

55 180 75 250 90 300 125 400 190 630 220 800

90 180 132 250 160 300 220 400 330 630 440 800

110 180 132 200 160 250 225 350 330 500 500 720

110 120 132 150 200 220 250 300 330 420 500 630

hp A hp A hp A hp A hp A hp A

230 275 350 450 660 900

15 15

30 40

60 60 100 125 150 250

60 75 100 150 200 300

125 150 200 300 400 600

125 150 200 300 400 600

4 4 5 5 6 7

GMC-180/4 GMC-220/4 GMC-300/4 GMC-400/4 GMC-600/4 GMC-800/4

230 275 350 450 660 900

180A 220A 300A 400A 600A 800A

GT- 220

Setting ranges (A)

65 - 100

85 - 125

100 - 150

120 - 180

160 - 240GT- 400

Setting ranges (A)

85 - 125

100 - 150

120 - 180

160 - 240

220 - 300

260 - 400

Setting ranges (A)

220 - 300

260 - 400

400 - 600

520 - 800

AU-1001NO+1NC, Side mount

GT- 800

Dimension (mm)

Recommended