LP 51 Lesson Title 113-005 Setup Communications Lesson Number

Preview:

Citation preview

LP 5 1

Lesson Title

113-005

Setup Communications

Lesson Number

LP 5 2

LESSON OBJECTIVES

• Setup communications with other equipment.– Load Crypto Variable with a KYK-13 and

AN/CYZ-10. – COM Port Setup Page Configuration using

advanced function set – DAGR to DAGR Information Transfer (Basic

Function Set) – Synchronize DAGR with another device

LP 5 3

TOPIC OVERVIEW

• Introduction– Crypto Fill Page– Field Descriptions

• Operations– Load Crypto Variable with a KYK-13– Load Crypto Variable with a AN/CYZ-10

LP 5 4

Crypto Fill Page

• Caution – Loaded Crypto Keys– Classified at the same

level as Waypoints

• Note– Crypto Keys

LP 5 5

• Crypto Fill Page – Crypto Keys– Status Key to check Crypto

Variable Keys (CV)– Not enough CV Keys

loaded– False data called Selective

Availability (SA)– Encrypted to deny users

reception of signals is called Anti-Spoofing (A-S)

Crypto Fill Page

LP 5 6

REF Para 7.2.3.1.c

Crypto Key Entry using the KYK-13

(1) Connect the KYK-13 to the J1 connector

on the DAGR using the crypto keyfill cable.

CRYPTO KEY ENTRY KYK-13

LP 5 7

CRYPTO KEY ENTRY KYK-13

(2) From the Crypto Fill page, highlight the CV Loading Interface field. Push the ENTER key.

(3) Highlight DS-102, then push the ENTER key.

• CV Loading Interface field– DS-101– DS-102

LP 5 8

(4) Set the KYK-13 selector switch to the position that contains the crypto key.

(5) Set the KYK-13 mode switch to ON.

Note KYK-13 repeatedly pulses

CRYPTO KEY ENTRY KYK-13

LP 5 9

(6) Set the KYK-13 mode switch to OFF after at least one KYK-13 flash has been observed (for red key only) . Disconnect the KYK- 13 and cable from the DAGR.

No CV Keys Loaded

Have Today’s CV Key

No CV Key for Today

Waiting for SV Info

CRYPTO KEY ENTRY KYK-13

LP 5 10

(7) Acknowledge any DAGR messages and observe the CV Status field on the Crypto Fill page.

Note

Generate a successful key load message and generates a warning message (Invalid CV Loaded).

CRYPTO KEY ENTRY KYK-13

LP 5 11

Crypto Fill Page

• Mission Duration Field• Days Remaining With

CVs Field• Active Cryptonet Code

Field

• Primary Cryptonet Code Field

LP 5 12

Check on Learning

• What does the Crypto Fill Page display?

– Current status of crypto variable (CV) keys. Para 7.2.1

• What does CV stand for?

– Crypto variables. Para 7.2.1

• What CV interface code is required for using the KYK-13?

– DS-102 is required when using the KYK13. Para 7.2.3.1.c

LP 5 13

CRYPTO KEY ENTRY AN/CYZ-10

REF Para 7.2.3.1.e Crypto Key Entry using the AN/CYZ-10

Note: - Red Keys Only

(1) From the Crypto Fill page, highlight the CV Loading Interface field. Push the ENTER key.

(2) Highlight DS-101, then push the ENTER key.

(3) Connect the crypto keyfill cable to the J1 connector on the DAGR. Do not connect the crypto keyfill cable to the AN/CYZ–10 until instructed by this procedure.

LP 5 14

Note- Following steps refer to the AN/CYZ-10.

(4) Power the AN/CYZ-10 on (if not already powered on). The display shows SOI RADIO SUPERVISOR.

(5) Select RADIO from the display.

(6) Display shows SETUP COMSEC TIME. Select COMSEC from the display.

CRYPTO KEY ENTRY AN/CYZ-10

LP 5 15

(7) Display shows VG LD RV AK MK VU. Select LD from the display.

(8) Display shows TEK KEK. Select TEK from the display.

(9) Push the PgDN or PgUP keys, as required, to view the desired key, then push the ENTR key.

CRYPTO KEY ENTRY AN/CYZ-10

LP 5 16

Note- Ignore Instructions relating to an RT

(10) Display shows QUIT (Key Name/Number) XMT. Select QUIT from the display.

(11) Display shows CONNECT ANCD TO RT (WAIT) (↓). Push the down arrow key

(12) Display shows PRESS (LOAD) ON RT. Connect the crypto keyfill cable to the AN/CYZ-10. The crypto key is automatically loaded into the DAGR.

CRYPTO KEY ENTRY AN/CYZ-10

LP 5 17

(13) Acknowledge any DAGR messages and observe the CV Status field on the Crypto Fill page.

(14) After the key is loaded, disconnect the crypto keyfill cable from the AN/CYZ-10 and the DAGR.

CRYPTO KEY ENTRY AN/CYZ-10

LP 5 18

Practical Exercise

• Load CV with a KYK-13• Load CV with an AN/CYZ-10

LP 5 19

TOPIC SUMMARY

• Introduction– Crypto Fill Page– Field Descriptions

• Operations– Load Crypto Variable with a KYK-13– Load Crypto Variable with a AN/CYZ-10

LP 5 20

TOPIC OVERVIEW

• Introduction– COM Port Setup Page– Field Descriptions

• Operations– COM Port Setup Page Configuration

using advanced function set

LP 5 21

COM Port Setup Page

• COM Port Setup Page – Configures COM1,

COM2, and COM3• Protocol• In/Out Baud• In/Out Parity

– Standard Configuration

– National Marine Electronics Association

LP 5 22

• Configuration Field• Operator Identifier

Field

COM Port Setup Page

LP 5 23

Check on Learning

• COM Port 1 and COM Port 2 are accessed from what connector?

– Connector J2. Para 11.3.1

• What does the Out Protocol Field (Advanced) display?

– Displays the protocol as ICD-153 or NMEA, used to output data. Paragraph 11.3.2.6

LP 5 24

TOPIC SUMMARY

• Introduction– COM Port Setup Page– Field Descriptions

• Operations– COM Port Setup Page Configuration

using advanced function set

LP 5 25

TOPIC OVERVIEW

• Introduction– Data Transfer Page– Field Descriptions

• Operations– DAGR to DAGR Information Transfer

(Advanced Function Set)

LP 5 26

Data Transfer

• DAGR to DAGR

– Basic and Advanced Function set

• DAGR to PLGR

– Basic and Advanced Function set

• PLGR to DAGR

– Basic and Advanced Function set

LP 5 27

Data Transfer Page

• Note– Data Transfer Page Field

Data

• Data Transfer Page Function

LP 5 28

DAGR TO DAGR INFORMATION TRANSFER

Ref Para 11.2.3.1 b DAGR to DAGR Information Transfer

(Advanced Function Set)

(1) Connect both DAGRs together with the DAGR to DAGR data cable assembly using the J2 external connector on both units.

(2) Push the PWR key to set power ON for both DAGRs. Acknowledge power-on status display if required.

LP 5 29

DAGR TO DAGR INFORMATION TRANSFER

(3) Set both DAGRs to use the Advanced Function Set.

LP 5 30

(4) On both DAGRs, from the main menu, highlight Communications. Push the ENTER key. Highlight COM Port Setup, then push the ENTER key.

(5) On the COM Port Setup page of both DAGRs, set the COM field to COM Port 1.

(6) On the COM Port Setup page of both DAGRs, set the Configuration field to Standard.

DAGR TO DAGR INFORMATION TRANSFER

LP 5 31

(7) On the sending DAGR, push the PAGE key to access the Data Transfer page.

(8) On the Data Transfer page of the sending DAGR, set the COM Port field to COM Port 1.

(a) Highlight the COM Port field, then push the ENTER key.

(b) Highlight COM Port 1, then push the ENTER key.

DAGR TO DAGR INFORMATION TRANSFER

LP 5 32

DAGR TO DAGR INFORMATION TRANSFER

(9) On the Data Transfer page of the sending DAGR, set the Mode field to DAGR.(a) Highlight the Mode field,

then push the ENTER key.

(b) Highlight DAGR, then push the ENTER key.

- COM PORT Field - Mode Field

LP 5 33

(10) On the Data Transfer page of the sending DAGR, select the type of data to be sent in the Data To Transfer field.

(a) Highlight the Data To Transfer field, then push the ENTER key.

(b) Highlight the desired selection, then push the ENTER key.

Note– Transferring Waypoint

DAGR TO DAGR INFORMATION TRANSFER

LP 5 34

• Data To Transfer Field– All Data – WP/Mission Data – SV/POS/Time Data – Setup Data – Display Setup – Position Report – User Datums– User Grids

• Data Transfer Page Description– From WP Field – To WP Field

DAGR TO DAGR INFORMATION TRANSFER

LP 5 35

DAGR TO DAGR INFORMATION TRANSFER

(11) On the Data Transfer page of the sending DAGR, push the MENU key, then highlight Start Data XFR. Push ENTER key to initiate the data transfer process.

LP 5 36

Transfer data

(12) Messages will show on both DAGR displays indicating the data transfer is starting, in progress, complete, aborted, or failed. Follow instructions on display.

(13) When data transfer is complete, perform one of the following:

(a) Set power to off on both pieces of equipment (push and hold DAGR PWR key). Remove the data cable assembly.

LP 5 37

Transfer data

(b) Disconnect the data cable assembly and perform other DAGR operations as desired.

NotePrevent an unintended DAGR power down.

LP 5 38

Check on Learning

• What is the Data Transfer Page used for?

– To transfer selected data from the DAGR over a selected receiver port. Para 11.2.1

• What does the Mode Field display?

– Displays type of data format to output. Para 11.2.2

• What should be set in the Mode Field during DAGR to DAGR transfer?

– Set to PLGR III or DAGR . Paragraph 11.2.3.1

LP 5 39

Practical Exercise

• Partner with another student and transfer data between your DAGRs.

LP 5 40

TOPIC SUMMARY

• Introduction– Data Transfer Page– Field Descriptions

• Operations– DAGR to DAGR Information Transfer

(Advanced Function Set)

LP 5 41

TOPIC OVERVIEW

• Introduction– PPS, HQ,SINCGARS Page– Field Descriptions

• Operations– Synchronize DAGR with another

device • Send timing signal to SINCGARS radio

LP 5 42

PPS, HQ,SINCGARS Page

• PPS, HQ,SINCGARS Page Function

• Note– COM Port Access

LP 5 43

PPS, HQ,SINCGARS Page

• PPS, HQ,SINCGARS Page Description– COM 1/2 PPS Mode

Field– COM 1/2 PPS Sync

Field– COM 3 PPS Mode

Field– Have Quick Mode

Field – TFOM Field

LP 5 44

SYNCHRONIZING SINCGARS PAGE

Ref Para 11.4.3.1Synchronizing SINCGARS

Page

• Note– All fields use list editor

a. From the PPS, HQ, SINCGARS page, push the ENTER key to highlight a field.

b. Scroll to highlight the desired field, then push the ENTER key for edit capabilities.

LP 5 45

c. Revise the selected field with appropriate information.

d. Use the cursor control keys and the ENTER key in a similar manner to select and individually revise all of the remaining fields as required.

SYNCHRONIZING SINCGARS PAGE

LP 5 46

e. When all fields are revised with appropriate information, push the MENU key.

SYNCHRONIZING SINCGARS PAGE

LP 5 47

SYNCHRONIZING SINCGARS PAGE

f. Connect DAGR to external equipment and ensure external equipment is powered on before activating the

SINCGARS function. • Note

– Connect DAGR

g. Highlight Activate SINCGARS, then push the ENTER key and follow display instructions and messages.

LP 5 48

Check on Learning

• What does the PPS,HQ, SINCGARS page provide? – Provides time outputs from the

DAGR used to synchronize radios or other devices.

• What does the COM 1 / 2 PPS Mode Field display? – Displays the port selected for

outputting PPS time outputs (of the COM 1 and COM 2 PPS Mode).

LP 5 49

TOPIC SUMMARY

• PPS, HQ,SINCGARS Page

• Field Descriptions

• Operations– Synchronize DAGR with another

device

LP 5 50

Practical Exercise

• Send a timing signal from your DAGR to a SINCGARS radio.

LP 5 51

LESSON SUMMARY

• You have now learned how to setup communications with other equipment.– Load Crypto Variable with a KYK-13. – COM Port Setup Page Configuration using

advanced function set – DAGR to DAGR Information Transfer (Basic

Function Set) – Synchronize DAGR with another device

Recommended