View
225
Download
6
Category
Preview:
Citation preview
Introduction to Chemical Engineering
CHE-201
4.5 RECYCLE AND BYPASS
Air Conditioner Unit:
Fresh air containing 4.00 % water vapor is to be cooled and dehumidified to a
water content of 1.70 mole % H2O. A stream of fresh air is combined with a
recycle stream of previously dehumidified air and passed through the cooler. The
blended stream entering the unit contains 2.30 mole % H2O. In the air conditioner,
some of the water in the feed stream is condensed and removed as liquid. A
fraction of the dehumidified air leaving the cooler is recycled and the remainder is
delivered to a room. Taking 100 mol of dehumidified air delivered to the room as a
basis of calculation. Calculate the moles of fresh feed, moles of water condensed,
and moles of dehumidified air recycled.
Air Conditioner Unit:
AIRCOND.
n1 (mol)
0.960 DA0.040 W (v)
n2 (mol) n4 (mol)
0.977 DA0.023 W (v)
0.983 DA0.017 W (v)
0.983 DA0.017 W (v)
0.983 DA0.017 W (v)
n5 (mol)
n3 [mol W(l)]
DA = Dry AirW = Water
100 mol
An Evaporative Crystallization Process:
The flowchart of a steady-state process to recover crystalline chromate (K2CrO4) from an aqueous solution of this salt is shown
below:
Forty-five hundred kilograms per hour of a solution that is one-third K2CrO4 by mass is joined by a recycle stream containing
36.4% K2CrO4, and the combined stream is fed into an evaporator. The concentrated stream leaving the evaporator contains
49.4% K2CrO4; this stream is fed into a crystallizer in which it is cooled (causing crystals of K2CrO4 to come out of solution) and
then filtered. The filter cake consists of K2CrO4 crystals and a solution that contains 36.4 % K2CrO4 by mass; the crystal account
for 95% of the total mass of the filter cake. The solution that passes through the filter, also 36.4% K2CrO4, is the recycle stream.
1. Calculate the rate of evaporation, the rate of production of crystalline K2CrO4, the feed rates that the evaporator and
crystallizer must be designed to handle, and the recycle ratio (mass of recycle)/(mass of fresh feed).
2. Suppose that the filtrate were discarded instead of being recycled. Calculate the production rate of crystals. What are the
benefits and costs of the recycling?
EVAPORATOR CRYSTALIZERAND FILTER
H2O
4500 kg/h
33.3% K2CrO4
49.4% K2CrO4
Filtrate36.4% K2CrO4 solution
Filter cakeK2CrO4 solid
36.4 % K2CrO4 solution(the crystals constitute 95% by mass of the filter cake)
Process Flowchart:
EVAPORATOR CRYSTALIZERAND FILTER
Fresh feed4500 kg/h
0.33 kg K/kg0.667 kg W/kg
0.494 kg K/kg0.506 kg W/kg
Filtrate (recycle)m6 (kg /h)
m5 (kg soln/h)0.364 kg K/kg0.636 kg W/kg
Filter cakem4 (kg K(s)/h)
0.364 kg K/kg0.636 kg W/kg
x1 (kg K/kg)(1-x1) (kg W/kg)
m1 (kg /h)
m2 (kg W(v)/h)
m3 (kg /h)
Recommended