View
221
Download
3
Category
Preview:
Citation preview
Intelligent GSM
Auto-dial Alarm System
User’s Manual
Profile
For a better understanding of this product, please read this user
manual thoroughly before using it.
2
CONTENTS [Function Instruction]
[Control Panel Introduction]
[Door Contact]
[PIR Detector]
[Initialization]
[Voice Recording]
[Monitor Panel Power]
[Connect Outdoor Siren]
[Monitor GSM Signal]
[Function Settings]
1. Pair Remote Controls
2. Pair Wireless Sensors
3. Command Chart
[Operation Instructions]
1. Arm/ disarm Operation
2. Emergency Help
3. Alarming
4. Remote Control
[Technical Parameters]
[Components List]
[Care and Maintenance]
3
[Function Instruction] � 96 wireless and 3 wired defense zones; each could be programmed
independently and the alarm SMS is editable;
� Maximum 99 remote controls; both IC 2262 and EV 1527 compatible;
� Control panel tamper alarm;
� Sensor low-power alarm, and sensor tamper alarm; it will send SMS when
alarming;
� English voice prompt for all operations;
� 5 groups alarm phone number and 5 SMS number;
� One relay link to arm or disarm; one relay support remote control;
� External power failure/ recovery alert;
� System settings could be finished by SMS or call DTMF;
� Built-in RF transmitter: easy to set with wireless sirens;
� 10-second voice recording: will be heard when receiving alarm call;
[Control Panel Introduction] In order to make the main panel get the wireless signal well for all wireless accessories, please put the alarm host at the central place of your defense area. Make sure it’s away from large metal objects and household appliances which may cause high frequency interference, as well as barriers such as reinforced concrete wall or fire door, etc.
4
LED indicator:
LED LED Status System working status
POWER OFF No power
ON (red) Power supply is normal
Flashing slowly in red Powered by built-in battery
STATUS Flash per second
(orange)
Checking GSM network and
SIM card
ON (orange) GSM network or SIM card is
abnormal
ON (green) Disarm status
Flash per second
(green)
Away arm status
Flash every 2 seconds Home arm status
ON (red) Alarming
Flash per second (red) Delay alarming
Flash quickly in red Under remote control
5
MON/SPK ON Monitor/ intercom status
REC ON Recording
Flash quickly Record replaying
RF ON Remote controller/ wireless
sensor paring
ZONE ON Wireless sensor paring
OUT2 OFF Relay P2 is disconnected
ON (red) Relay P2 is connected
OUT1 OFF Relay P1 is disconnected
ON (red) Relay P1 is connected
Alarm panel built-in buzzer:
Buzzer Status System working status
Short beep Paring completed
One short beep System arm
Long beep for
500ms
GSM network checked successful; receiving correct
SMS
Two short beeps System disarm
Four short beeps Repeat paring
Voice Prompt Correspondent Operation
system armed Away arm/ home arm
system disarmed Disarm
coding completed Remote controls or wireless sensors paring
please enter password Prompt for remote control operation
6
wrong password When you input a wrong password
delete completed Deletion is successful.
setting completed The setting is correct.
please enter instruction After correct password
Back panel:
Wired terminal block:
7
1 SPK+ Positive of siren (red cable)
2 SPK- Negative of siren (black cable)
3 LB+ Positive of speaker (red cable)
4 LB- Negative of speaker (black cable)
5 P1
This switch will be connected when arming; and
disconnected when disarming. 6
7 P2
Use command to set it connected/ disconnected.
Please refer to the “command chart” part on page 9 8
9 Z1 Wired sensor 1 (zone number: 97)
10 Z2 Wired sensor 2 (zone number: 98)
11 Z3 Wired sensor 3 (zone number: 99)
12 GND Ground
8
Note:
1. Please pay attention to the siren connection. Positive side to “SPK+”
and negative to “SPK-”. Do not mix the two cables together when
connecting. Otherwise, it will damage the transistor in the main panel.
2. Wired sensor connection: connect one cable of the wired sensor to GND
and the other to “Z1, Z2 or Z3”.
3. Relay P1 will be connected when system armed, and the OUT1 indicator
will be on. It will be disconnected when system disarmed, and the
OUT1 indicator will be off.
[Door Contact] Door sensors are used for detecting the status of open and close of windows
and doors. It will detect it and send the signal to main panel.
� Tear apart the double-side adhesive tape on the magnet and the
transmitter. Then adhere them to the appropriate position.
� Magnet should
be near to the
side of
transmitter with
indicator. The
two should
align with each
other and the
distance should not exceed 10mm.
� Please plug out the antenna for better signal.
� If the low-power indicator is on, please change the battery.
9
[PIR Detector] PIR detectors are used to detect the movement within a certain range.
� Fix the
adjustment
bracket on the
wall with the
provided screws
and attach the
detector to the bracket. It is recommended to mount it at a height of
2-2.2m above the floor.
� Effect of the PIR detection is best when the detection direction is in 90°
angle with the walking direction of the intruder. Choose the most
suitable installation place and angle according to actual situation and
taking the following installation diagram as reference to ensure the
detection effect is best.
� Please do not fix it under direct sunlight or other strong lights and also
keep it away from places with frequent strong air stream.
� If the low-power indicator is on, please change the battery.
[Initialization] -Please insert SIM card. Make sure the card has enough balance to make call and send sms. -Connect the siren, wired sensors, or relay -Plug in power adaptor, and turn on the power switch. The POWER indicator will be on and the STATUS LED flashes in orange. The system starts checking the GSM network.
10
-After checking the SIM card and GSM network normally, the panel will make a long beep and the STATUS LED will turn green. At this time, the system enters into disarm status. If the GSM network is not checked successfully, the STATUS LED will be in orange. -Pair the extra wireless sensors and remote controllers that are not included in the standard pack, and make function settings. [Voice Recording] In disarm status, press the “REC” button at the back side of the panel. REC indicator at the front panel will turn on. You can start recording now. 10 seconds later, it will exit recording and play the recorded voice automatically. At the same time, the REC light will flash quickly. After playing record, you can press REC button again to re-record. [Monitor Panel Power] This system has the function of SMS alert for external power failure and recovery. When the external power is cut off, the built-in LI battery will keep the system working. The SMS content for external power disconnection: Power charger off; power recovery: Power charger on. [Connect Outdoor Siren] The alarm panel has built-in transmitter which can work together with wireless sirens. You need not to connect external transmitters. Setting method: -turn on the Wireless Transmission function (check the command chart on page 12); -make the siren into coding status (check the siren manual); -make the control panel into disarm status, and then press the SOS button on the remote control. The panel will send signal to the siren. The siren will make a beep sound after successfully receiving which means setting completed. -siren: exit coding status.
11
[Monitor GSM Signal] This system has the function of alert for bad GSM signal. When the GSM signal is less than 10, the panel will send SMS “bad GSM signal”. And when the signal is equal to 0, the siren will start ringing for 5 minutes. The factory default for this function is off, you can turn it on by “password#17#0#” (check the command chart on page 10).
[Function Settings] 1. Pair Remote Controls Extra remote controls have to be set with the control panel in order to perform normally. The one in the standard package has been paired. This alarm system supports maximum 99 remote controls. Find the RF button next to the SIM card slot. Press it during disarm status. The RF LED turns on and then press any button on the remote control. You will hear a beep sound which means setting is successful. Then press the RF button again to save the setting. If the panel makes four short beeps, it means the remote control has been paired before or the remote control number exceeds 99. 2. Pair Wireless Sensors Wireless detectors have to be set with the control panel in order to trigger it alarm. The wireless PIR sensor and door contact in the standard package have been paired. This alarm system has 96 wireless defense zones. Press the RF button twice during disarm status. The RF LED and ZONE LED both turn on. At this time, trigger the sensor you want to set. You will hear a beep sound which means setting is successful. Then press the RF button again to save the setting. If the panel makes four short beeps, it means the sensor has been paired before or the sensor number exceeds 96. The serial number of the remote controls and sensors is defined by the setting sequence. That means, the first remote control set is NO.1, and the third
12
sensor set is in NO.3 zone. 3. Command Chart For all the settings of this alarm system, you can finish by sending SMS or making call to the control panel. The SMS content: password#command Default password: 123456 Alarm receiving: after receiving alarm call, you can do the settings directly without inputting password. Command Function Setting
method Alarm receiving
1#1# Away arm Call or SMS YES
1#2# Home arm
1#0# Disarm
11#1# Siren on when alarm (default) NO
11#0# Siren off when alarm
12#1# Send SMS when alarm (default)
12#0# No SMS when alarm
15#1# Make call when alarm (default)
15#0# No call when alarm
17#1# GSM signal monitor activated YES 17#0# GSM signal monitor deactivated
(default) 3#1# Turn on the siren immediately Call 3#0# Turn off the siren 30## Inquire the system status SMS NO 31#xxxxxx#
Change password (default: 123456)
Call or SMS
32## Inquire GSM signal (0~31) SMS 33## Inquire IMEI code (15-digit)
13
35#xx# Set the siren ring time (default: 3min; xx: 0~15min)
Call or SMS
36#0# Delete all settings except sensors and remote controls
36#1# Delete sensors 36#2# Delete remote controls
38#AA#B#C#
Defense zone type setting. AA: defense zone number (01~99); B: zone type (1: 24 hours; 2: real-time; 3: delay; 4: bypass.); C: home arm setting (0: deactivate, 1: activate); after activation, in home arm status, when the sensor in this zone is triggered, it will trigger alarm. Default: all defense zones are real time, home arm deactivated. Call and SMS setting both ok.
39#AA#xx#
Alarm SMS setting. AA: defense zone number (01~99); xx: SMS content (maximum 16 characters)
SMS
4#0# Turn off listen-in Call YES 4#1# Turn on listen-in 40#1# Turn on Wireless Transmission Call or SMS NO 40#0# Turn off Wireless Transmission
(default)
41#xxxx# Wireless Siren Coding Encryption (xxxx: 0000~9999; default: FFFF)
42#1# Turn on SMS reply function (default)
42#0# Turn off SMS reply function 43#1# Turn on arm/disarm SMS
14
notification 43#0# Turn off arm/disarm SMS
notification (default) 44#xx# Arm/ exit delay time setting
(00~99seconds, default: 0) 45#xx# Disarm/ entry delay time setting
(00~99seconds, default: 0)
46#1# Turn on arm/ disarm voice prompt
46#0# Turn off arm/ disarm voice prompt (default)
47#1# Turn on all voice prompt 47#0# Turn off all voice prompt
(default) 48#1# Turn on the panel buzzer
(default) 48#0# Turn off the panel buzzer
50## Inquire alarm phone numbers SMS 51#X# Set alarm phone number (1st) X:
maximum 15 numbers Call or SMS
52#X# Set alarm phone number (2nd) 53#X# Set alarm phone number (3rd) 54#X# Set alarm phone number (4th) 55#X# Set alarm phone number (5th)
51## Delete alarm phone number (1st) 52## Delete alarm phone number
(2nd) 53## Delete alarm phone number (3rd) 54## Delete alarm phone number (4th) 55## Delete alarm phone number (5th) 60## Inquire alarm SMS numbers SMS
61#X# Set alarm SMS number (1st) X: maximum 15 numbers
Call or SMS
15
62#X# Set alarm SMS number (2nd) 63#X# Set alarm SMS number (3rd) 64#X# Set alarm SMS number (4th) 65#X# Set alarm SMS number (5th)
61## Delete alarm phone number (1st) 62## Delete alarm phone number
(2nd) 63## Delete alarm phone number (3rd) 64## Delete alarm phone number (4th) 65## Delete alarm phone number (5th)
92#1# Turn on the siren for arm/disarm operation
92#0# Turn off the siren for arm/disarm operation (default)
93#1# Turn on two-way intercom Call YES
93#0# Turn off two-way intercom (default)
94#1# Connect relay P2 Call or SMS
94#0# Disconnect relay P2
95#1# Set zone 97 as NO NO
95#0# Set zone 97 as NC (default)
96#1# Set zone 98 as NO
96#0# Set zone 98 as NC (default)
97#1# Set zone 99 as NO
97#0# Set zone 99 as NC (default)
951753082
46##
Factory reset (all settings are deleted and all the sensors and remote controls are deleted)
98#1# Turn on tamper alarm function
16
98#0# Turn off tamper alarm function (default)
99## Delete the common SMS content (check explanation in “Note”)
99#xx#
Set common SMS. xx: SMS content (maximum 30 characters)
SMS
Note: * Common SMS content: after this setting, all the alarm SMS will start with this content you set. For example, “99#Tom#”, you may receive alarm message like this “Tom 1 Zone Alarm!”. System default for this is empty. *Factory reset: you can also do it like this: keep pressing the “REC” button and “RF” button at the same time for 5 seconds. You will hear 6 beeps. * For the above settings, if you set by SMS, you will receive a message from the system for confirmation. This function could be set as off if you do not need the confirmation SMS (42#0#). But for the following settings, SMS reply could not be set off: 1. Inquiry setting: Inquire the system status, inquire GSM signal, inquire
IMEI, alarm telephone number and SMS number. 2. Arm/ disarm the system by SMS. * SMS setting is easily affected by GSM network which may cause delay, so it’s recommended to do the settings by call. * Please make your mobile phone as English version when you send SMS. Please check all the SMS reply in the following table.
Command SMS Reply
17
1#1# System armed
1#2# Home armed
1#0# System disarmed
11#1# Siren when alarming enabled
11#0# Siren when alarming disabled
12#1# Alarm SMS Enabled
12#0# Alarm SMS Disabled
15#1# Alarm Phone Call Enabled
15#0# Alarm Phone Call Disabled
17#1# GSM Signal Monitor Enabled
17#0# GSM Signal Monitor Disabled
30##
System armed
Home armed
System disarmed
31#password# Password set to: 6-digit numbers
32## GSM Signal: (01~31)
33## IMEI: (15-digit)
35#xx# Siren ringing time set to: xx minutes
36#0# All settings except coding information
deleted
36#1# All defense zone deleted
36#2# All remote controls deleted
18
38#AA#B#C#
AA: 01-99; B: 1-4
1: 24 hours defense
zone; 2: real-time
defense zone; 3: delay
defense zone; 4: bypass
defense zone
C: 0-1
0: invalid; 1: valid
For example:
123456#08#3#0#
SMS Reply:
Zone: 08
Defense Zone Type: delay defense zone
Home Arm Defense Zone: invalid
39#AA#xx#
AA: 01-99
xx: SMS content
For example:
123456#39#08#gas leakage#
SMS Reply:
User defined sms content zone: 08 gas
leakage
40#1# Wireless Transmission Control: ON
40#0# Wireless Transmission Control: OFF
41#XXXX# Wireless Siren Coding Encryption: xxxx
42#1# SMS reply: ON
42#0# SMS reply: OFF
43#1# SMS Notification for Arm/disarm: ON
43#0# SMS Notification for Arm/disarm: OFF
44#XX# Arm Delay Time: xx seconds
45#XX# Alarm Delay Time: xx seconds
46#1# Arm/Disarm Voice Guide Prompt: ON
19
46#0# Arm/Disarm Voice Guide Prompt: OFF
47#1# Voice guide: ON
47#0# Voice guide: OFF
48#1# Voice of Buzz: ON
48#0# Voice of Buzz: OFF
50##
No phone number;
Or
Call phone number 1: xx
Call phone number 2: xx
Call phone number 3: xx
Call phone number 4: xx
Call phone number 5: xx
51#xxxxx# Call phone number 1: xxxxx
52#xxxxx# Call phone number 2: xxxxx
53#xxxxx# Call phone number 3: xxxxx
54#xxxxx# Call phone number 4: xxxxx
55#xxxxx# Call phone number 5: xxxxx
51## Call phone number 1 deleted
52## Call phone number 2 deleted
53## Call phone number 3 deleted
54## Call phone number 4 deleted
55## Call phone number 5 deleted
60##
No SMS number;
Or
SMS phone number 1: xx
20
SMS phone number 2: xx
SMS phone number 3: xx
SMS phone number 4: xx
SMS phone number 5: xx
61#xxxxx# SMS phone number 1: xxxxx
62#xxxxx# SMS phone number 2: xxxxx
63#xxxxx# SMS phone number 3: xxxxx
64#xxxxx# SMS phone number 4: xxxxx
65#xxxxx# SMS phone number 5: xxxxx
61## SMS phone number 1 deleted
62## SMS phone number 2 deleted
63## SMS phone number 3 deleted
64## SMS phone number 4 deleted
65## SMS phone number 5 deleted
92#1# Enable the external siren sound when use
remote controller to Arm/Disarm
92#0# Disable the external siren sound when use
remote controller to Arm/Disarm
94#1# Relay P2: ON
94#0# Relay P2: OFF
95#1# Z1 97 defense zone set to: NO
95#0# Z1 97 defense zone set to: NC
96#1# Z1 98 defense zone set to: NO
96#0# Z1 98 defense zone set to: NC
97#1# Z1 99 defense zone set to: NO
21
SMS content for alarming:
Alarm type SMS content
Tamper alarm The tamper alarm button on the back side of the panel is bounced up (not in setting status)
System Tamper Alarm!
Emergency button on the remote control
Remote X SOS Alarm! (X is the remote control serial number 1~99)
Wireless and wired sensors
For “real-time, 24 hours or delay” defense zone: X zone Alarm! (X is the defense zone serial number 1~96) For “close” defense zone, trigger the sensor, it will not make alarm.
Sensor low power (note: the sensor should have low power alarm function)
X zone Low Power! (X is the defense zone number of the sensor 1~96)
Sensor tamper alarm (note: the sensor should have tamper alarm function)
X zone Tamper Alarm! (X is the defense zone number of the sensor 1~96)
97#0# Z1 99 defense zone set to: NC
95175308246## System reset
98#1# Alarm panel tamper switch enabled
98#0# Alarm panel tamper switch disabled
99## Common SMS content deleted
99#xxxxxx# Common SMS content set to: xxxxxx
22
[Operation Instructions] 1. Arm/ disarm Operation Set the system into arm status means making it work (guarding your house or place you install). When there is an alarm triggered, you will receive alarm call and sms, at the same time the siren will ring. You can disarm it to stop alarming. Away Arm: all detectors keep working. STATUS indicator flashes slowly in green. a. Press [OUT ARM] button on the remote controls b. Send SMS to the alarm panel: password#1#1# c. Call the alarm panel: password, 1#1# Home Arm: part of the detectors keep working. How to set the detectors working or not, please check the [command chart] “Defense zone type setting” on page 11. STATUS indicator flashes quickly in green. a. Press [HOME ARM] button on the remote controls b. Send SMS to the alarm panel: password#1#2# c. Call the alarm panel: password, 1#2# Disarm: STATUS LED keeps on in green a. Press [DISARM] button on the remote controls b. Send SMS to the alarm panel: password#1#0# c. Call the alarm panel: password, 1#0#
2. Emergency Help Press SOS button on the remote control. No matter the system is in arm or disarm status, it will make alarm immediately. 3. Alarming Answer Alarm Call When the main panel sounds the alarm, it will dial the preset numbers. If no one answers the call, the system will call the next user number automatically. The system will call each preset numbers for 3 times in order. If you answer the call, you will hear the pre-record voice for 3 times. You can
23
set system via your phone. If you hang-up directly without answering the call, the system will keep calling the next number. Press [1#1#]: System stops alarming and Away Arm; it stops calling users. Press [1#2#]: System stops alarming and Home Arm; it stops calling users. Press [1#0#]: System stops alarming and Disarm; it stops calling users. Press [4#1#]: Starts listen-in. Press [93#1#]: Starts two-way intercom. Press [94#1#]: Turn relay on. Press [94#0#]: Turn relay off. All the settings in the command chart that support “call setting” could be done after you receive alarm call. 4. Remote Control Dial the number associated to the control panel by phone (mobile phone), and after one ringing cycle, you can hear a voice prompt “Please enter password”. Input the password (default: 123456). If there’s no operation within 60 seconds, the call will be hung up directly. If the password is wrong, you will hear a prompt voice “error, please re-enter”. If the password is right, you will hear “ok, please enter instruction”. Now you can do all the settings in the command chart that support “call setting”. [Note] If the voice prompt is turned off, you will hear beeps for operation. A long beep after the call gets through, you can start to input password. For each pressing, there will be a short beep sound. If there’s no beep sound, please re-enter. And there will be four short beeps for wrong operation. [Technical Parameters] Power supply: AC=100V~250V, DC=12V, 1.2A Built-in battery: 7.4V, 1000mA LI battery (keep working for about 8hrs after external power failure)
24
Standby current: 65mA GSM band: 850/900/1800/1900MHz Wireless frequency: 433MHz ±0.5MHz Wireless receiving sensitivity: 5mV/m Wireless modulation: ASK Anti-interference: 1V/m (frequency range: 20~1000 MHz) Wireless sensors: 96pcs Remote controllers: 99pcs Working temperature: 0℃~+40℃ Humidity: ≤90% (no fog)
[Components List] Control panel 1 pc,
Remote controls 2 pcs,
Wired mini siren 1 pc,
PIR sensor 1 pc,
Door contact 1 pc,
Power adapter 1 pc,
User manual 1 pc.
[Care and Maintenance] The alarm system has excellent design and uses advanced technologies. It
shall be used with care. The following suggestions are required to maintain
your obligations under the warranty terms, and for prolonging the service life
of the system.
� Place the control panel and all parts and accessories out of children’s
reach.
25
� Keep the alarm system dry. Rain, humidity and various fluids or
moisture all will corrupt the electronic circuit.
� Do not use or place the alarm system in dirty locations, otherwise the
electronic elements will be damaged.
� Do no place the system in excessively hot locations. High temperature
will shorten the service life of electronic equipment, damage batteries, deform
or even melt some plastic parts.
� Do not place the system in excessively cold locations. Otherwise
condensation many occur and damage the circuit board of the alarm system.
� It is recommended that you check and test the alarm system
periodically:
Check the main unit every three months:
1. Whether it can arm/disarm normally;
2. Whether it can dial the number for alarm normally;
3. Whether it can receive wireless detectors’ signal normally;
4. Whether the back-up battery can work normally.
Check the wireless detectors once a month:
1. Trigger wireless detectors to see if system can alarm normally;
2. Check all detectors’ batteries to see if it’s in low voltage;
3. Check whether wireless detectors can send signal to the main unit
normally.
Check the SIM card:
1. Check the use of SIM card, such as network signal, balance, etc.
2. Make sure the PIN code verification of the SIM card is closed.
3. Please keep the password and SIM card number safe, in case that other
people remote control the system illegally.
26
� Since the alarm system is continuously in operation or standby mode,
the supply adaptor of the control panel shall be connected to a safe and
reliable socket.
� Do not place the system near your bedroom or office table, because the
siren will make high-loudness sound in the case of alarm, which may
adversely affect your rest or work.
� If the alarm system will not be used for a long time, please disconnect
the system from the power supply.
� Please do not disassemble, repair or alter the products without
permission, or it may cause accidents and faults.
� Do not drop this product on the ground or on hard objects, as it may lead
to massive impact to cause faults and damages.
� Without approval and consent of relevant authorities, please do not set
“112”, “911” or the alarm phone number of police station for this main unit.
Please read the suggestions above carefully and follow the instructions herein.
If any of the equipment does not work properly, please send it to the dealer or
authorized service point for repair. We will try our best to solve the problem
for you as soon as possible.
The following accessories are optional: