Instruction D8 Profili Manhat - Zaneen

Preview:

Citation preview

A2min

.7

5m

m

41

/3"

58 mm

2 2/7"

D8 Profili - ManhattanInstallation Instruction

30 Tycos Drive, Toronto, Ontario, Canada M6B 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com tech@zaneen.com Page 1 of 7

D8 Profili - ManhattanInstallation Instruction

Installation Type 1:

A1

A2

Ceiling installation with false ceiling already installed (exclusively for straight segments without corners)

D8 Profili - ManhattanInstallation Instruction

30 Tycos Drive, Toronto, Ontario, Canada M6B 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com tech@zaneen.com Page 2 of 7

D8 Profili - ManhattanInstallation Instruction

Ceiling installation without false ceiling (the distance "X" between the ceiling and the bottom of the bracket unit and the frameof the false ceiling must be the same)

A1

A2

A4

X X XX

58 mm

2 2/7"

2

Installation Type 2:

A1

A2

A4

D8 Profili - ManhattanInstallation Instruction

30 Tycos Drive, Toronto, Ontario, Canada M6B 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com tech@zaneen.com Page 3 of 7

D8 Profili - ManhattanInstallation Instruction

A1

A3

X X

58 mm

2 2/7"

Installation using a segment flush to the wall without false ceiling (the distance "X" between the ceiling and the bottom of thebracket unit and the frame of the false ceiling must be the same; it is necessary to fix the plates "A3" to the wall)

Installation Type 3:

A1A3

D8 Profili - ManhattanInstallation Instruction

30 Tycos Drive, Toronto, Ontario, Canada M6B 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com tech@zaneen.com Page 4 of 7

D8 Profili - ManhattanInstallation Instruction

Installation Type 4:

A1

A2min

.75

mm

3"

58 mm

2 2⁄7"

Wall installation with drywall already installed (exclusively for straight segments without corners)

D8 Profili - ManhattanInstallation Instruction

30 Tycos Drive, Toronto, Ontario, Canada M6B 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com tech@zaneen.com Page 5 of 7

D8 Profili - ManhattanInstallation Instruction

Installation Type 5:

Wall installation without drywall (the distance "X" between the ceiling and the bottom of the bracket unit and the frame of thefalse ceiling must be the same)

A1 A2X X X58 mm

2 2⁄7"

D8 Profili - ManhattanInstallation Instruction

30 Tycos Drive, Toronto, Ontario, Canada M6B 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com tech@zaneen.com Page 6 of 7

D8 Profili - ManhattanInstallation Instruction

Installation Type 6:

Wall installation without drywall (the distance "X" between the ceiling and the bottom of the bracket unit and the frame of thefalse ceiling must be the same)

A1 A2X

58 mm

2 2⁄7"

6

D8 Profili - ManhattanInstallation Instruction

30 Tycos Drive, Toronto, Ontario, Canada M6B 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com tech@zaneen.com Page 7 of 7

D8 Profili - ManhattanInstallation Instruction

2 4 3

3

1

1

3

2

Linear junction Angle 2 horizontal 90 ° wall-wall / ceiling–ceiling,

external measurements 110x110mm

1 2

Angle 1 horizontal 90 ° wall-wall / ceiling–ceiling,

external measurements 110x110mm

Angle 3 vertical 90 ° wall-ceiling / wall-wall,

external measurements 110x110mmAngle 4 horizontal 90 ° wall-wall, external

measurements 110x110mmPower compartment (optional) with screws

for installation on the junction

3 4

Joints guide:

Recommended