D8 Profili - ManhattanInstallation Instruction
30 Tycos Drive, Toronto, Ontario, Canada M6B 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com [email protected] Page 1 of 7
D8 Profili - ManhattanInstallation Instruction
Installation Type 1:
A1
A2
Ceiling installation with false ceiling already installed (exclusively for straight segments without corners)
D8 Profili - ManhattanInstallation Instruction
30 Tycos Drive, Toronto, Ontario, Canada M6B 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com [email protected] Page 2 of 7
D8 Profili - ManhattanInstallation Instruction
Ceiling installation without false ceiling (the distance "X" between the ceiling and the bottom of the bracket unit and the frameof the false ceiling must be the same)
A1
A2
A4
X X XX
58 mm
2 2/7"
2
Installation Type 2:
A1
A2
A4
D8 Profili - ManhattanInstallation Instruction
30 Tycos Drive, Toronto, Ontario, Canada M6B 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com [email protected] Page 3 of 7
D8 Profili - ManhattanInstallation Instruction
A1
A3
X X
58 mm
2 2/7"
Installation using a segment flush to the wall without false ceiling (the distance "X" between the ceiling and the bottom of thebracket unit and the frame of the false ceiling must be the same; it is necessary to fix the plates "A3" to the wall)
Installation Type 3:
A1A3
D8 Profili - ManhattanInstallation Instruction
30 Tycos Drive, Toronto, Ontario, Canada M6B 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com [email protected] Page 4 of 7
D8 Profili - ManhattanInstallation Instruction
Installation Type 4:
A1
A2min
.75
mm
3"
58 mm
2 2⁄7"
Wall installation with drywall already installed (exclusively for straight segments without corners)
D8 Profili - ManhattanInstallation Instruction
30 Tycos Drive, Toronto, Ontario, Canada M6B 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com [email protected] Page 5 of 7
D8 Profili - ManhattanInstallation Instruction
Installation Type 5:
Wall installation without drywall (the distance "X" between the ceiling and the bottom of the bracket unit and the frame of thefalse ceiling must be the same)
A1 A2X X X58 mm
2 2⁄7"
D8 Profili - ManhattanInstallation Instruction
30 Tycos Drive, Toronto, Ontario, Canada M6B 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com [email protected] Page 6 of 7
D8 Profili - ManhattanInstallation Instruction
Installation Type 6:
Wall installation without drywall (the distance "X" between the ceiling and the bottom of the bracket unit and the frame of thefalse ceiling must be the same)
A1 A2X
58 mm
2 2⁄7"
6
D8 Profili - ManhattanInstallation Instruction
30 Tycos Drive, Toronto, Ontario, Canada M6B 1V9 PH: 800.388.3382 / 416.247.9221 FAX: 416.247.9319 www.zaneen.com [email protected] Page 7 of 7
D8 Profili - ManhattanInstallation Instruction
2 4 3
3
1
1
3
2
Linear junction Angle 2 horizontal 90 ° wall-wall / ceiling–ceiling,
external measurements 110x110mm
1 2
Angle 1 horizontal 90 ° wall-wall / ceiling–ceiling,
external measurements 110x110mm
Angle 3 vertical 90 ° wall-ceiling / wall-wall,
external measurements 110x110mmAngle 4 horizontal 90 ° wall-wall, external
measurements 110x110mmPower compartment (optional) with screws
for installation on the junction
3 4
Joints guide: