occfiber.com | 1
INDUSTRIAL TRAY CABLE PRODUCTS
Overviewocc’s new product line for Power and control Tray cable for industrial applications
offers a robust and dependable product with enhanced mechanical and environmental
performance features. The new occ product has the unique combination of being Power
and control Tray cable UL 1277 rated for power, optical fiber, exposed run, and sunlight
resistant and has options for copper shielding. in addition, these new hybrid cables offer
users a variety of copper and fiber configurations designed for challenging environments.
While many fiber optic cable manufacturers have claimed to have “tray rated” fiber
optic cables, occ’s fiber optic tray cables have always been third party verified to meet
the functional requirements of tray cable standards by incorporating occ’s proven
ruggedized cable constructions.
Incredible mechanical and environmental performance. occ‘s Tc-of Tray cable with optical fiber and optional exposed run design
contains power conductors and multiple fiber optic elements. Durable enough to survive the weight of other heavy cables and industrial
temperature extremes, they are approved for use directly in cable trays along with other power cables. The exposed run rating means
the cables are approved for installation where sections are left as open wiring even without the protection of a cable tray. in addition,
they maintain the low flammability required of indoor cables.
Incorporated fiber optic elements. by integrating occ’s fiber optic cables with the power cable, the customer has better protection
for the optical fibers and reduced installation costs by installing one cable in the place of several individual cables.
Variety of configuration options. The new Tc-of product set can be configured in a multitude of cable constructions. Additionally,
they complement occ’s fiber optic tray cable equivalent family with UL ofNr listing. The expansion of this new family of cables opens
up a broad mix of most industrial, conveyance, surface mining, and fTTA applications.
Applications• industrial
• conveyance
• Surface mining
• fTTA
2 | occfiber.com
INDUSTRIAL TRAY CABLE PRODUCTSCX-Series Hybrid - UL 1277 Tray Cables
Applications• Usedforpowerandcontrolcircuitsthatrequirebothpowerconductorsand
fiber optic communication links• Hybridfiber/coppercablesasdescribedinNECArticle336PowerandControl
Tray cable Type Tc-of• TypeTC-OF-ERcablecantransitionfromacabletraytotheequipment
Features and Benefits• Corrugatedcoppershieldingisavailable• TypeTC-OF-ERcableisalsoapprovedforusebetweenthecabletrayandequipmentwheninstalledtoNEC336.10(7)
• 600Vratingfor90°Cdryandwetlocations• Cableconstructedofcopperconductors,fiberopticalcomponents,flame
retardant fillers and tape wrap• BaregroundingconductorforTC–ERcables• IndividualconductorsareTypeTHHNandTHWN-2andcanbeAWG10toAWG14• Sunlightresistantjacketforcontinuoussunlightexposureperformance• UL1685VerticalFlameTestperformance(70,000BTU/hr)• Thefiberopticcomponentscanvaryfromindividualtomulti-fibersubunitsas
determined by the construction, which includes the number of fibers, number of conductors and the conductor size
• ForfibertypeoptionsseetheFiberProductSection3• Manyfibercountoptionsavailable• incorporating fiber optic elements into the power cable provides protection for the optical fibers and reduced installation costs by installing one cable in the place of several individual cables
Cable Characteristics• Duetothewidevarietyofcableconstructions,includingconductorcounts,
conductor sizes, fiber types and fiber counts, individual cable characters are available upon request
Ordering Information• Duetothecustomnatureofthiscable,contactOCCSalesforordering
information
1. Corrugated Copper Shielding 2. Ripcord 3. Tight-Buffer Optical Fiber 4. Copper wire 5. Central Filler/Strength Member 6. Aramid Strength Member 7. Outer Jacket 8. Subcable Jacket
1.
2.
3.
4.
5.
6.
7.
Applicable StandardsOCCindoor/outdoortight-buffered fiber optic cables meet the functional requirements of the following standards:
• UL 1277
• UL1685VerticalFlameTest
• UL83–THHNandTHWN-2
conductors
• NEC–NFPA70Section336
1.
2.
3.
4.
5.
6.
7.8.
occfiber.com |3
INDUSTRIAL TRAY CABLE PRODUCTSB-Series Breakout – Riser Rated Tray Cables
Applications• Idealforinstallationsrequiringanextremelyruggedandreliablecabledesign
where maximum mechanical and environmental protection are necessary• Typicalindustrialusesarefactoryautomation,powergenerationandother
utilities, oil and gas refining, and surface mining• Easiestcabletoinstallwheredirectterminationofthesubcabletoaconnector
and a direct run to panels and equipment are desired• Idealforlocationsrequiringlow-temperatureperformancealongwithaflame
rating
Features• Individualfibersandstrengthmembersprotectedinasubcableconfiguration• Mostruggedcabledesignwithindividualsubcablesforroutingtodiverse
intelligent devices with direct connector termination at each device• IndependentlytestedtoCSAC22.2No.230(traycables)• Fibersmaybedirectlyterminatedatfactorydevicesorcentrallocationsusing
connectors with no further protection required• JjacketisUV,fungusandmoistureresistant• Designedforindoor/outdoorinstallations,includingcabletrays• 2to72fibercountsareavailablewith2.0mmor2.5mmsubcables• Low-temperaturePVCouterjacket(Jmaterial)providesexcellentperformance
and flexibility at low temperatures• Wideoperatingtemperaturerangeof-50ºCto+75ºC• Core-Locked™jacketpreventscablefromflatteningandthejacketfromwrinkling
in tight bends• Permitspullingwithdirectattachmentofwiremeshgrip;noneedtoaccess
inner aramid strength members• Improvescrushandtearresistance• Contains25%morematerialthanconventionaljackets
• Highcrushandtensileloadratingscomparedtosimilartrayservicefiberopticcables
• Oilresistantforuseinindustrialapplications• ULlistedinaccordancewithNECsection770.179(b)foruseinverticalrunsin
building riser shafts or from floor to floor• DesignedtoexceedtheflammabilityrequirementsofChapter8ofIEEE383
Applicable StandardsOCCindoor/outdoortight-buffered fiber optic cables meet the functional requirements of the following standards:
• ICEA-S-83-596• ICEA-S-104-696• GR-409-COREISSUE2• TIA-568• TIA-598• UL1666• CSAC22.2No.232• CSAC22.2No.230
1. Central Filler/Strength Member 2. Subcable 3. Outer Jacket 4. RipcordSubcable 5. Tight-Buffer Optical Fiber 6. Aramid Strength Member 7. Subcable Jacket
1.
2.
3.
4. Subcable
5.
6.
7.
4| occfiber.com
INDUSTRIAL TRAY CABLE PRODUCTSB-Series Breakout – Riser Rated Tray Cables
Mechanical and Environmental PerformanceINDOOR/OUTDOOR
Operating temperature -50°C to + 75°C
Storage temperature -55°C to + 85°C
Installation temperature (cable temp.) -30°C to + 60°C
Flame retardancy UL listed type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232)
Impact resistance (TIA-455-25A) 1,500 impacts
Crush resistance (TIA-455-41A) 2,200 N/cm
Flex resistance (TIA-455-104A) 2,000 cycles
FIBER COUNT DIAMETER MM (IN)
WEIghT kg/kM (LBS/1,000')
TENSILE LOAD MINIMUM BEND RADIUS
INSTALLATION N (LBS) OPERATIONAL N (LBS) INSTALLATION CM (IN) LONg-TERM CM (IN)
2 7.0 (0.28) 41 (28) 1,200 (270) 500 (110) 10.5 (4.1) 7.0 (2.8)
4 8.3 (0.33) 68 (46) 2,000 (450) 800 (180) 12.5 (4.9) 8.3 (3.3)
6 9.6 (0.38) 88 (59) 3,000 (670) 1,200 (270) 14.4 (5.7) 9.6 (3.8)
8 11.6 (0.46) 133 (89) 4,000 (900) 1,700 (380) 17.4 (6.9) 11.6 (4.6)
12 14.1 (0.55) 159 (107) 6,000 (1,350) 2,500 (560) 21.2 (8.3) 14.1 (5.5)
18 15.3 (0.60) 226 (152) 8,000 (1,800) 3,500 (790) 23.0 (9.1) 15.3 (6.0)
24 17.6 (0.69) 292 (196) 10,000 (2,250) 3,800 (850) 26.4 (10.4) 17.6 (6.9)
30 20.9 (0.82) 383 (257) 14,000 (3,150) 6,000 (1,350) 31.4 (12.3) 20.9 (8.2)
36 20.9 (0.82) 375 (252) 14,000 (3,150) 6,000 (1,350) 31.4 (12.3) 20.9 (8.2)
48 24.2 (0.95) 501 (336) 18,000 (4,050) 7,500 (1,690) 36.3 (14.3) 24.2 (9.5)
60 28.5 (1.12) 773 (519) 22,000 (4,950) 8,800 (1,980) 42.8 (16.8) 28.5 (11.2)
72 28.9 (1.14) 768 (516) 26,000 (5,845) 11,000 (2,470) 43.4 (17.1) 28.9 (11.4)
Cable Characteristics: B-Series Breakout Riser Rated Tray Cables (with 2.5mm subcables)
Installationloadsinexcessof2,700N(600lbs.)arenotrecommended.Otherfibercountsavailableuponrequest.
occfiber.com |5
INDUSTRIAL TRAY CABLE PRODUCTSB-Series Breakout – Riser Rated Tray Cables
Ordering Information
B 9
12-fiberriserratedtraycableusing62.5µmstandardLaserUltra-Foxfiber2.5mmsubcable,blackjacket–
1–2 BreakoutSeriesUltra-FoxTrayCables: 2.0mmSubcables=BE 2.5mmSubcables=BX 3–5 Fibercount:(seecablecharacteristicschart)=002–072 6 Jackettype:Indoor/OutdoorTray=J 7–9 Fibertype:(seeLaserUltra-FoxFiberPerformanceTable,p.23) 10 Ultra-Foxfiberwith900µmtight-buffer=9 11 Standardjacketcolor:Black=K 12 Rating:Riser=R
1 2 3 4 5 6 7 8 9 10 11 12
Example:
B X 0 1 2 J W L S 9 K R
J K R
Digit No.:
FIBER COUNT DIAMETER MM (IN)
WEIghT kg/kM (LBS/1,000')
TENSILE LOAD MINIMUM BEND RADIUS
INSTALLATION N (LBS) OPERATIONAL N (LBS) INSTALLATION CM (IN) LONg-TERM CM (IN)
2 6.0 (0.24) 40 (27) 800 (180) 200 (40) 9.0 (3.5) 6.0 (2.4)
4 6.9 (0.27) 52 (35) 1,600 (360) 400 (90) 10.4 (4.1) 6.9 (2.7)
6 8.1 (0.32) 67 (45) 2,400 (540) 600 (130) 12.2 (4.8) 8.1 (3.2)
8 9.4 (0.37) 88 (59) 3,200 (720) 800 (180) 14.1 (5.6) 9.4 (3.7)
12 10.9 (0.43) 108 (73) 4,800 (1,000) 1,200 (270) 16.4 (6.5) 10.9 (4.3)
18 12.6 (0.50) 156 (105) 6,000 (1,350) 1,500 (340) 18.9 (7.4) 12.6 (5.0)
24 14.7 (0.58) 218 (146) 7,200 (1,600) 1,800 (400) 22.1 (8.7) 14.7 (5.8)
30 16.8 (0.66) 268 (180) 9,600 (2,100) 2,400 (540) 25.2 (9.9) 16.8 (6.6)
36 16.8 (0.66) 266 (179) 9,600 (2,100) 2,400 (540) 25.2 (9.9) 16.8 (6.6)
48 20.1 (0.79) 387 (260) 12,000 (2,700) 3,000 (680) 30.2 (11.9) 20.1 (7.9)
60 22.7 (0.89) 489 (329) 15,000 (3,400) 3,750 (850) 34.1 (13.4) 22.7 (8.9)
72 26.0 (1.02) 652 (438) 16,800 (3,800) 4,200 (900) 39.0 (15.4) 26.0 (10.2)
Cable Characteristics: Breakout Tray Cables (with 2.0mm subcables)
Installationloadsinexcessof2,700N(600lbs.)arenotrecommended.
6| occfiber.com
INDUSTRIAL TRAY CABLE PRODUCTSG-Series Subgrouping – Riser Rated Tray Cables
Applications• Idealforinstallationsrequiringaruggedandreliablecabledesignwheremaximummechanicaland
environmental protection are necessary• Typicalindustrialusesarefactoryautomation,powergenerationandotherutilities,oilandgasrefining,
and surface mining
Features• Bestdesignformultimodeandsingle-modefibercomposite/hybridcables• Designallowsmulti-fibersubcablestoberoutedtomultiplelocationssuchaswiringracksandclosets• IndependentlytestedtoCSAC22.2No.230(traycables)• Color-codedsubcablesareeasytoidentifyforimprovedcablemanagementinroutingandtermination• Designedforindoor/outdoorinstallations,includingcabletrays• 12-to144-fiberconfigurationsareavailablewith6or12fiberspersubcable• Low-temperaturePVCouterjacket(Jmaterial)providesexcellentperformanceandflexibility at low temperatures• JacketisUV,fungusandmoistureresistant• Core-Locked™jacketpreventscablefromflatteningandthejacketfromwrinklingintightbends• Permitspullingwithdirectattachmentofwiremeshgrip;noneedtoaccessinner aramid strength members• Improvescrushandtearresistance• Contains25%morematerialthanconventionaljackets
• Highcrushandtensileloadratingscomparedtosimilartrayservicefiberopticcables
• Oilresistantforuseinindustrialapplications• ULlistedinaccordancewithNECsection770.179(b)foruseinverticalrunsin
building riser shafts or from floor to floor• DesignedtoexceedtheflammabilityrequirementsofChapter8IEEE383
Applicable StandardsOCCindoor/outdoortight-buffered fiber optic cables meet the functional requirements of the following standards:
• ICEA-S-83-596• ICEA-S-104-696 • GR-409-COREISSUE2• TIA-568• TIA-598• UL1666• CSAC22.2NO.232• CSAC22.2NO.230
Mechanical and Environmental PerformanceINDOOR/OUTDOOR
Operating temperature -50°C to +75°C
Storage temperature -55°C to +85°C
Installation temperature (cable temp.) -30°C to +60°C
Flame retardancy UL listed type OFNR (UL 1666) FT4 (CSA C22.2 No. 232)
Impact resistance (TIA-455-25A) 1,500 impacts
Crush resistance (TIA-455-41A) 2,100 N/cm
Flex resistance (TIA-455-104A) 2,000 cycles
1. CentralFiller/StrengthMember 2. Subcable 3. OuterJacket 4. RipcordSubcable 5. Tight-BufferOpticalFiber 6. AramidStrengthMember 7. SubcableJacket 8. Ripcord
1.
2.
3.
4.
Subcable
5.
6.
7.
8.
occfiber.com | 7
INDUSTRIAL TRAY CABLE PRODUCTSG-Series Subgrouping – Riser Rated Tray Cables
g-Series Subgrouping Tray Cable with 6-Fiber Subcables (4.5mm subcables)
FIBER COUNT DIAMETER MM (IN)
WEIghT kg/kM (LBS/1,000')
TENSILE LOAD MINIMUM BEND RADIUS
INSTALLATION N (LBS) OPERATIONAL N (LBS) INSTALLATION CM (IN) LONg-TERM CM (IN)
12 14.6 (0.57) 221 (149) 3,800 (850) 1,200 (270) 21.9 (8.6) 14.6 (5.7)
18 14.6 (0.57) 222 (149) 4,700 (1,060) 1,800 (400) 21.9 (8.6) 14.6 (5.7)
24 14.6 (0.57) 223 (150) 5,600 (1,260) 1,900 (420) 21.9 (8.6) 14.6 (5.7)
30 15.6 (0.61) 254 (171) 7,500 (1,690) 2,400 (540) 23.4 (9.2) 15.6 (6.1)
36 16.9 (0.67) 297 (200) 8,900 (2,000) 2,850 (640) 25.4 (10.0) 16.9 (6.7)
g-Series Subgrouping Tray Cable with 12-Fiber Subcables (5.5mm subcables)
FIBER COUNT DIAMETER MM (IN)
WEIghT kg/kM (LBS/1,000')
TENSILE LOAD MINIMUM BEND RADIUS
INSTALLATION N (LBS) OPERATIONAL N (LBS) INSTALLATION CM (IN) LONg-TERM CM (IN)
24 16.6 (0.65) 274 (184) 4,600 (1,030) 1,500 (340) 24.9 (9.8) 16.6 (6.5)
36 16.6 (0.65) 272 (183) 5,900 (1,330) 1,050 (440) 24.9 (9.8) 16.6 (6.5)
48 16.6 (0.65) 270 (181) 7,200 (1,620) 2,400 (540) 24.9 (9.8) 16.6 (6.5)
60 18.4 (0.72) 323 (217) 9,500 (2,140) 3,150 (710) 27.6 (10.9) 18.4 (7.2)
72 20.1 (0.79) 380 (255) 11,300 (2,540) 3,750 (840) 30.2 (11.9) 20.1 (7.9)
84 21.8 (0.86) 443 (298) 13,100 (2,950) 4,350 (980) 32.7 (12.9) 21.8 (8.6)
96 23.6 (0.93) 513 (345) 14,900 (3,350) 4,950 (1,110) 35.4 (13.9) 23.6 (9.3)
108 25.7 (1.01) 608 (409) 18,200 (4,090) 6,000 (1,350) 38.6 (15.2) 25.7 (10.1)
120 27.7 (1.09) 707 (475) 19,500 (4,380) 6,450 (1,450) 41.6 (16.4) 27.7 (10.9)
132 28.1 (1.11) 669 (450) 20,800 (4,680) 6,900 (1,550) 42.2 (16.6) 28.1 (11.1)
144 28.1 (1.11) 668 (449) 22,100 (4,970) 7,350 (1,650) 42.2 (16.6) 28.1 (11.1)
Ordering Information
Digit No:
G J K R9
1 2 3 4 5 6 7 8 9 10 11 12
48-fiberriserratedtraycable(12-fibersubcables)using62.5µmstandardLaserUltra-Foxfiber,blackjacket–Example:
G X 0 4 8 J W L S 9 K R
1 SubgroupingSeriesUltra-Fox=G 2 6-fibersubcables=B;12-fibersubcables=X 3–5 Fibercount:6-fibersubcables=012–036,12-fibersubcables=024–144 6 Jackettype:Indoor/OutdoorTray=J 7–9 Fibertype:(seeLaserUltra-FoxFiberPerformanceTable,p.23) 10 Ultra-Foxfiberwith900µmtight-buffer=9 11 Standardjacketcolors:Black=K(otherjacketcolorsavailableuponrequest) 12 Rating:Riser=R
Installationloadsinexcessof2,700N(600lbs.)arenotrecommended.other fiber counts available upon request.
Recommended