MAGNA3 vs MAGNA Range

32 F (N) 1.25”

40 F (N)1.5”

50 F (N)2”

65 F (N)2.5”

80 F3”

100 F4”

xx-60

xx-80

xx-100

xx-120

xx-150

xx-180

“Old” MAGNA

MAGNA3 with Dual Head Option

MAGNA3

50 100150200250300350400450500 600550

10

20

30

40

50

60

Old Magna

Magna3

Technical data

MAGNA3 “Old” MAGNA

Max. Head 60 Ft. 40 Ft.

Max. Flow550 GPM

(Dual or Parallel)170 GPM

Max. Power 1550 W 900W

Connections 1" to 4" 1" to 2.5"

Liquid Temperature 14F to 230F 35F to 230F

Ambient Temperature 32F to 104F 32F to 104F

Nominal Pressure 145 PSI 145 PSI

Cast Iron Pump House ● ●

Stainless Pump House ● ●

MAGNA3 “Old” MAGNA

AUTOADAPT ● ●

FLOWADAPT ● ○

FLOWLIMIT ● ○

Proportional Pressure ● ●

Constant Pressure ● ●

Constant Speed ● ●

Constant Temperature ● ○

Automatic Night Setback ● ●

Control Modes

Readings and Settings

MAGNA3 “Old” MAGNA

Control panel and displayColor TFT

Screenand Buttons

Button and LEDs

Operating status ● Control ModePump performance ● ○Warning and alarm ● ●Heat energy meter ● ○Work log history ● ○Dry-running detection ● ○Status menu ● Requires R100Fitted modules ● ○(CIM module connected to the pump)

●Requires CIU and

GeniModuleTime and date ● ○Pump identification ● ●

Interface

MAGNA3 “Old” MAGNA

Display type Color TFT Screen LEDs

ButtonsSilicone push-

buttonsOne silicone push-

button

Descriptions Graphics and text Symbols

Grundfos Eye (Green), Running

● ○

Grundfos Eye (Yellow), Warning

● ○

Grundfos Eye (Red), Alarm ● ○

Inputs and Outputs

MAGNA3 “Old” MAGNA

Analog inputs1 x Analog input(0-10V/4-20 mA)

Requires

GeniModule1 x Analog Input

(0-10V)

Relay outputs 2 x relay outputs 1 Relay output

Digital inputs 3 x digital inputs 1 Digital Input

Dual Head Pump / Two Pump Operation

MAGNA3 “Old” MAGNA

Size and no. of dual head pumps

2.5" to 4"3 models

Communication between dual head pumps

Wireless communication

Communication between dual head pumps

Wireless communication

Multi-pump system ● ●

Alternating operation ● ●

Back-up operation ● ●

Parallel operation ● ○

Communications and Monitoring

MAGNA3“Old”

MAGNA

Hand held pump control

Wireless Grundfos GO remote

control by means of :

iPod, iPad, iPhone, Android phone

R100

BUS communication

Wireless GENIair incorporated

Optional CIM cards

Requires GeniModule

and CIU

Insulation Shells

MAGNA3 “Old” MAGNA

Heating

Shell for heating applications are

delivered as standard for single pumps (part of the

package).

Shell for heating applications are

delivered as standard for single pumps (part of the

package).

Cooling

For cooling applications, apply silicone sealant to standard insulation

shell per instructions

For cooling applications, apply silicone sealant to standard insulation

shell per instructions