SS-DSG3 www.daikinac.com 12/17Supersedes 8/17
3 - 5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER
Up to 81% Efficient
DSG Commercial
■ ContentsNomenclature ........................................ 2Product Specifications ........................... 4Expanded Cooling Data ....................... 13Airflow Data ......................................... 19Crankercase Heater ............................. 27Electrical Data ...................................... 28Dimensions .......................................... 29Wiring Diagrams ................................. 33– for Models with DDC Controls .............. 53 Accessories ......................................... 54
■ Standard Features• Patented tubular heat exchanger• High-efficiency scroll compressor• High and low-pressure switches• Copper tube / aluminum fin coils• Contactor with lugs• High-capacity, steel-cased filter drier• 24-volt terminal strip• Convertible airflow orientation• Easy to service• Built-in filter rack with standard 2" filters• Bottom utility entry
■ Cabinet Features• Heavy-gauge, galvanized-steel cabinet
with UV-resistant powder-paint finish• Full Perimeter Rail• Sloped drain pan
• Complies with California Low NOx emissions standards• 3-5 Tons with single speed blower motor
units meet the performance specified in Table 6.8.1-1 of ASHRAE Standard 90.1-2013
• AHRI Certified; ETL Listed
* Complete warranty details available from your local distributor or manufacturer’s representative or at www.daikincomfort.com.
Cooling Capacity: 35,000 — 58,000 BTU/hHeating Capacity: 46,000 —138,000 BTU/H
2 www.daikinac.com SS-DSG3
Nomenclature
D S G 060 090 3 B * * * A *1 2 3 4,5,6 7,8,9 10 11 12 13 14 15 16
Revision LevelsMajor & Minor
Brand Factory-Installed OptionsD Daikin X No Options
A Non-powered convenience outletConfiguration B Powered convenience outletC Standard Efficiency (6 - 25 Tons) C Low-ambient kitS Standard Efficiency (3 - 5 Tons) D Return air smoke detectorT High Efficiency (3 - 5 Tons) E Supply air smoke detector
F Non-powered convenience outlet; Application Low-ambient kitC Cooling1 G Non-powered convenience outlet; G Gas Heat Return air smoke detectorH Heat Pump1 H Non-powered convenience outlet;
Supply air smoke detectorNominal Cooling Capacity J Non-powered convenience outlet;036 3 Tons 102 8½ Tons 300 25 Tons Return & Supply air smoke detectors048 4 Tons 120 10 Tons K Non-powered convenience outlet;060 5 Tons 150 12½ tons Low-ambient kit; Supply air smoke detector072 6 Tons 180 15 Tons L Non-powered convenience outlet; 090 7½ Tons 240 20 Tons Low-ambient kit
Return & Supply air smoke detectorsNominal Heating Capacity M Powered convenience outlet;
Gas/Electric A/C H/P Factory-Installed Electric Heat Low-ambient kit045 45,000 BTU/h XXX No Heat N Powered convenience outlet;070 70,000 BTU/h 010 10 kW 030 30 kW Return air smoke detector090 90,000 BTU/h 015 15 kW 031 30 kW O Powered convenience outlet;115 115,000 BTU/h 016 15 kW 045 45 kW Return & Supply air smoke detectors140 140,000 BTU/h 018 18 kW 046 45 kW P Powered convenience outlet;210 210,000 BTU/h 020 20 kW 060 60 kW Supply air smoke detector350 350,000 BTU/h 025 25 kW Q Powered convenience outlet; Low-ambient400 400,000 BTU/h kit; Return air smoke detector
See product specifications for heat size(s) available for each capacity. R Powered convenience outlet; Low-ambientVoltage kit; Supply air smoke detector1 208-230/1/60 4 460/3/60 T Powered convenience outlet; Low-ambient3 208-230/3/60 7 575/3/60 kit; Return & Supply air smoke detectors
U Non-powered convenience outlet;Supply Fan/Drive Type/Motor Low-ambient kit; Return air smoke detectorB Belt Drive (single speed) V Two-Speed Belt Drive (also designates 6-Ton V Low-ambient kit; Return air smoke detectorD Direct Drive (3-5 Tons) with two-stage compressor) W Low-ambient kit; Supply air smoke detector
H High Static (single-speed Belt Drive models only) Y Low-ambient kit; Return & SupplyFactory-Installed Options air smoke detectorsA Ultra Low-Leak Downflow Economizer R Ultra Low-Leak Downflow Economizer; Z Return & Supply air smoke detectorsB DDC-BACnet protocol DDC-BACnet protocol; F Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused)
DDC-BACnet protocol V Low-Leak Downflow Economizer Factory-Installed OptionsH Disconnect Switch (non-fused) W Low-Leak Downflow Economizer X Standard Aluminized Heat ExchangerJ Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) S Stainless-Steel Heat Exchanger
Disconnect Switch (non-fused) X No Options D Hinged PanelsM Disconnect Switch (non-fused); DDC-BACnet protocol K Stainless-Steel Heat Exchanger;
Hinged PanelsNote: Not all options available for all products. B Phase Monitor
1 X= No Options in character 13th J Stainless Steel Heat Exchanger; Phase MonitorM Hinged Panel; Phase MonitorL Stainless-Steel Heat Exchanger;
Hinged Panels; Phase Monitor
SS-DSG3 www.daikinac.com 3
Factory-Installed Options• Stainless-Steel Heat Exchanger (Gas only units): A tubular heat exchanger made of 409-type stainless steel is installed in the unit.• Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the 3- to 6-ton units, cooling operation is extended
from 60°F ambient temperature to 35°F outside air temperature. On 7½ -20 ton units, cooling operation is extended from 35°F ambient temperature to 0°F outside air temperature. For 25 ton units, cooling operation is extended from 24°F ambient temperature to 0°F outside air temperature.
• Economizers (Downflow): Based on air conditions, can provide outside air to cool the space.• Electric Heat Kits (heat pump and cooling units only): Available in all voltage options.• Non-powered Convenience Outlet: A 120V, 15A, GFCI outlet makes it easier for technicians to service the unit once an electrician runs
power to the outlet.• Powered Convenience Outlet: A 120V, 15A, GFCI outlet powered with a transformer built into the unit. When a factory-installed powered
convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.2A/6.5A for 208/230V units, increase by 3.3A for 460V units, and by 2.6A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly.
• Disconnect Switch (non-fused; 3-phase units only): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note that for air conditioning and heat pump models, the appropriate electric heat kit must be ordered to be factory-installed along with the disconnect switch (non-fused) when it is ordered. Please note that for models with a powered con-venience outlet option and a disconnect switch (non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position.
• Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit.• Hinged Access Panels: Allows access to unit’s major components. Combined with latches for easy access to control box, compressor,
filters and blower motor. Available on all units.• Two-speed indoor fan blower models are available on 6, 7½, 8½, 10, 12½, 15, 20 & 25 ton units. Section 6.4.3.10.b of ASHRAE Standard
90.1-2010 and Section 6.5.3.2.1.a of ASHRAE Standard 90.1-2013 require a minimum of two fan speeds. Section 140.4(m)1 of California Energy Commission Title 24 2013 contains a similar provision. When the units with the two-speed indoor fan blowers operate on a call for the first stage of cooling, the fan operates at low speed, which is 66% of full speed. When the units operate on a call for the second stage of cooling, the fan operates at full speed. In heating operation, the fan operates at full speed. During ventilation operation, the fan operates at low speed.
• Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit.• Hinged Access Panels: Allows access to unit’s major components. Combined with latches for easy access to control box, compressor,
filters and blower motor. Available on all models.• Phase Monitor: Phase monitor (3 phase only), available for 3 - 25 ton DS, DC and DT series models. Phase monitor shall provide protection
for motors and compressors against problems caused by phase loss, phase reversal and phase unbalance. Phase monitor is equipped with an LED that provides an ON or FAULT indicator.
• DDC Controller: DDC communicating controller, available for 3 - 25 ton DS, DC and DT series models with on-board BACnet® communication interface.
4 www.daikinac.com SS-DSG3
Product Specifications — 3 Tons
DSG0360451D***A*
DSG0360453D***A*
DSG0360453B***A*
DSG0360454B***A*
Cooling CapacityTotal BTU/h 36,000 36,000 35,000 35,000
Sensible BTU/h 26,640 26,640 25,600 25,600
SEER / EER 14 / 12 14 / 12 14 / 12 14 / 12
Decibels 78 78 78 78AHRI Reference #s 9967131 9967134 9952114 9952120
Heating CapacityHigh Input / Output BTU/h 46 / 36.8 46 / 36.8 46 / 36.8 46 / 36.8
Low Input / Output BTU/h ---- ---- ---- ----
Thermal Efficiency (T.E.) ---- 80 80 80
Annual Fuel Utilization Efficiency (AFUE) 81 ---- ---- ----Temperature Rise Range (°F) Hi / Low 25-55 25-55 25-55 25-55
No. of Burners 2 2 2 2
Evaporator Motor / CoilMotor Type Direct Drive Direct Drive Belt Drive Belt Drive
Indoor Nominal CFM 1,250 1,250 1,200 1,200
Motor Speed Tap (Cooling) Low Speed Low Speed --- ---
Indoor Motor FLA (Cooling) 2.46 2.46 3.4 1.7
Horsepower - RPM 1/3 - 910 1/3 - 910 1.0 - 1725 1.0 - 1725
Piston Size (Cooling) 0.070 0.070 0.070 0.070
Filter Size (") (4) 14" x 20" x 2" (4) 14" x 20" x 2" (4) 14" x 20" x 2" (4) 14" x 20" x 2"
Drain Size (NPT) ¾" ¾" ¾" ¾"
R-410A Refrigerant Charge Cir #1 (oz.) 105 105 105 105
Evaporator Coil Face Area (ft²) 7.0 7.0 7.0 7.0Rows Deep / Fins per Inch 4 / 16 4 / 16 4 / 16 4 / 16
Belt Drive Evap Fan Data# of Wheels (D x W) ---- ---- 1 (11" x 10") 1 (11" x 10")
Motor Sheave ---- ---- 1VL34 X ⅝ 1VL34 X ⅝Blower Sheave / Belt ---- ---- AK61 x 1 / AX51 AK61 x 1 / AX51
Condenser Fan / CoilQuantity of Condenser Fan Motors 1 1 1 1
Horsepower - RPM ¼ - 1,075 ¼ - 1,075 ¼ - 1,075 ¼ - 1,050
Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22/4 22/4
Outdoor Nominal CFM 3,800 3,800 3,800 3,800
Face Area (ft²) 17.1 17.1 17.1 17.1Rows Deep/ Fins per Inch 1 / 24 1 / 24 1 / 24 1 / 24
CompressorQuantity / Type/ Stage 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / SingleCompressor RLA / LRA 16.7 / 79.0 10.4 / 73.0 10.4 / 73.0 5.8 / 38.0
Electrical DataVoltage-Phase-Frequency 208/230-1-60 208/230-3-60 208/230-3-60 460-3-60
Indoor Blower HP / FLA 1/3 / 2.46 1/3 / 2.46 1 / 3.4 1 / 1.7
Max. External Static 0.5" 0.5" 1.0" 1.0"
Outdoor Fan HP / FLA ¼ / 1.4 ¼ / 1.4 ¼ / 1.4 ¼ / 0.7
Min. Circuit Ampacity¹ 24.7 / 24.7 16.9 / 16.9 17.9 / 17.9 9.6
Max. Overcurrent Protection (amps)² 40 / 40 25 / 25 25 / 25 15
Power Supply Conduit Hole 1.125" 1.125" 1.125 1.125Low-Voltage Conduit Hole ½" ½" ½" ½"
Operating Weight (lbs) 565 565 565 565Ship Weight (lbs) 590 590 590 590
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Notes• Always check the S&R plate for electrical data on the unit being installed.
SS-DSG3 www.daikinac.com 5
DSG0360703B***A*
DSG0360704B***A*
Cooling CapacityTotal BTU/h 35,000 35,000
Sensible BTU/h 25,600 25,600
SEER / EER 14 / 12 14 / 12
Decibels 78 78AHRI Reference #s 9952114 9952120
Heating CapacityHigh Input / Output BTU/h 69 / 55 69 / 55
Low Input / Output BTU/h 51 / 41 51 / 41
Thermal Efficiency (T.E.) 80 80
Annual Fuel Utilization Efficiency (AFUE) ---- ----Temperature Rise Range (°F) Hi / Low 25-55 / 15-45 25-55 / 15-45
No. of Burners 3 3
Evaporator Motor / CoilMotor Type Belt Drive Belt Drive
Indoor Nominal CFM 1,200 1,200
Motor Speed Tap (Cooling) --- ---
Indoor Motor FLA (Cooling) 3.4 1.7
Horsepower - RPM 1.0 - 1725 1.0 - 1,725
Piston Size (Cooling) 0.070 0.070
Filter Size (") (4) 14" x 20" x 2" (4) 14" x 20" x 2"
Drain Size (NPT) ¾" ¾"
R-410A Refrigerant Charge Cir #1 (oz.) 105 105
Evaporator Coil Face Area (ft²) 7.0 7.0Rows Deep / Fins per Inch 4 / 16 4 / 16
Belt Drive Evap Fan Data# of Wheels (D x W) 1 (11" x 10") 1 (11" x 10")
Motor Sheave 1VL34 x ⅝ 1VL34 x ⅝Blower Sheave / Belt AK61 x 1 / AX51 AK61 x 1 / AX51
Condenser Fan / CoilQuantity of Condenser Fan Motors 1 1
Horsepower - RPM ¼ - 1,075 ¼ - 1,050
Fan Diameter/ # Fan Blades 22/4 22 / 4
Outdoor Nominal CFM 3,800 3,800
Face Area (ft²) 17.1 17.1Rows Deep/ Fins per Inch 1 / 24 1 / 24
CompressorQuantity / Type/ Stage 1 / Scroll/Single 1 / Scroll/SingleCompressor RLA / LRA 10.4 / 73.0 5.8 / 38.0
Electrical DataVoltage-Phase-Frequency 208/230-3-60 460-3-60
Indoor Blower HP / FLA 1 / 3.4 1 / 1.7
Max. External Static 1.0" 1.0"
Outdoor Fan HP / FLA ¼ / 1.4 ¼ / 0.7
Min. Circuit Ampacity¹ 17.9 10
Max. Overcurrent Protection (amps)² 25 15
Power Supply Conduit Hole 1.125 1.125Low-Voltage Conduit Hole ½" ½"
Operating Weight (lbs) 570 570Ship Weight (lbs) 595 595
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Notes• Always check the S&R plate for electrical data on the unit being installed.
Product Specifications — 3 Tons (cont.)
6 www.daikinac.com SS-DSG3
Product Specifications — 3 Tons (cont.)
DSG0360901D***A*
DSG0360903D***A*
DSG0360903B***A*
DSG0360904B***A*
DSG0360907B***A*
Cooling CapacityTotal BTU/h 36,000 36,000 35,000 35,000 35,000
Sensible BTU/h 26,640 26,640 25,600 25,600 25,600
SEER / EER 14 / 12 14 / 12 14 / 12 14 / 12 14 / 12
Decibels 78 78 78 78 78AHRI Reference #s 9967131 9967134 9952114 9952120 9952126
Heating CapacityHigh Input / Output BTU/h 92 / 75 92 / 74 92 / 74 92 / 74 92 / 74
Low Input / Output BTU/h 69 / 56 69 / 55 69 / 55 69 / 55 69 / 55
Thermal Efficiency (T.E.) ---- 80 80 80 80
Annual Fuel Utilization Efficiency (AFUE) 81 ---- ---- ---- ----Temperature Rise Range (°F) Hi / Low 30-60 / 20-50 40-70 / 30-60 40-70 / 30-60 25-55 25-55
No. of Burners 4 4 4 4 4
Evaporator Motor / CoilMotor Type Direct Drive Direct Drive Belt Drive Belt Drive Belt Drive
Indoor Nominal CFM 1,250 1,250 1,200 1,200 1,200
Motor Speed Tap (Cooling) LOW LOW --- --- ---
Indoor Motor FLA (Cooling) 2.46 2.46 3.4 1.7 2.3
Horsepower - RPM ⅓ - 910 ⅓ - 910 1.0 - 1725 1.0 - 1,725 1.5 - 1,725
Piston Size (Cooling) 0.070 0.070 0.070 0.070 0.070
Filter Size (") (4) 14" x 20" x 2" (4) 14" x 20" x 2" (4) 14" x 20" x 2" (4) 14" x 20" x 2" (4) 14" x 20" x 2"
Drain Size (NPT) ¾" ¾" ¾" ¾" ¾"
R-410A Refrigerant Charge Cir #1 (oz.) 105 105 105 105 105
Evaporator Coil Face Area (ft²) 7.0 7.0 7.0 7.0 7.0Rows Deep / Fins per Inch 4 / 16 4 / 16 4 / 16 4 / 16 4 / 16
Belt Drive Evap Fan Data# of Wheels (D x W) ---- ---- 1 (11" x 10") 1 (11" x 10") 1 (11" x 10")
Motor Sheave ---- ---- 1VL34 x ⅝ 1VL34 x ⅝ 1VL34 x ⅝Blower Sheave / Belt ---- ---- AK61 x 1 / AX51 AK61 x 1 / AX51 AK61 x 1 / AX51
Condenser Fan / CoilQuantity of Condenser Fan Motors 1 1 1 1 1
Horsepower - RPM ¼ - 1,075 ¼ - 1,075 ¼ - 1,075 ¼ - 1,050 ¼ - 1,050
Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22/4 22 / 4 22 / 4
Outdoor Nominal CFM 3,800 3,800 3,800 3,800 3,800
Face Area (ft²) 17.1 17.1 17.1 17.1 17.1Rows Deep/ Fins per Inch 1 / 24 1 / 24 1 / 24 1 / 24 1 / 24
CompressorQuantity / Type/ Stage 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / SingleCompressor RLA / LRA 16.7 / 79.0 10.4 / 73.0 10.4 / 73.0 5.8 / 38.0 3.8 / 36.5
Electrical DataVoltage-Phase-Frequency 208/230-1-60 208/230-3-60 208/230-3-60 460-3-60 575-3-60
Indoor Blower HP / FLA 1/3 / 2.46 1/3 / 2.46 1 / 3.4 1 / 1.7 1.5 / 2.3
Max. External Static 0.5" 0.5" 1.0" 1.0" 1.0"
Outdoor Fan HP / FLA ¼ / 1.4 ¼ / 1.4 ¼ / 1.4 ¼ / 0.7 ¼ / 0.55
Min. Circuit Ampacity¹ 24.7 / 24.7 16.9 / 16.9 16.9 / 16.9 9.6 7.6
Max. Overcurrent Protection (amps)² 40 / 40 25 / 25 25 / 25 15 15
Power Supply Conduit Hole 1.125" 1.125" 1.125 1.125 1.125Low-Voltage Conduit Hole ½" ½" ½" ½" ½"
Operating Weight (lbs) 575 575 575 575 575Ship Weight (lbs) 600 600 600 600 600
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Notes• Always check the S&R plate for electrical data on the unit being installed.
SS-DSG3 www.daikinac.com 7
DSG0480703B***A*
DSG0480704B***A*
Cooling CapacityTotal BTU/h 47,000 47,000
Sensible BTU/h 35,000 35,000
SEER / EER 14 / 11.8 14 / 11.8
Decibels 78 78AHRI Reference #s 9952115 9952121
Heating CapacityHigh Input / Output BTU/h 69 / 55 69 / 55
Low Input / Output BTU/h 51 / 41 51 / 41
Thermal Efficiency (T.E.) 80 80
Annual Fuel Utilization Efficiency (AFUE) ---- ----Temperature Rise Range (°F) Hi / Low 20-50 / 10-40 20-50 / 10-40
No. of Burners 3 3
Evaporator Motor / CoilMotor Type Belt Drive Belt Drive
Indoor Nominal CFM 1,600 1,600
Motor Speed Tap (Cooling) --- --
Indoor Motor FLA (Cooling) 3.4 1.7
Horsepower - RPM 1.0 / 1,725 1.0 / 1,725
Piston Size (Cooling) 0.074 0.074
Filter Size (") (4)14 x 20 x 2 (4)14" x 20" x 2"
Drain Size (NPT) ¾" ¾"
R-410A Refrigerant Charge Cir #1 (oz.) 111 111
Evaporator Coil Face Area (ft²) 7.8 7.8Rows Deep / Fins per Inch 4 / 16 4 / 16
Belt Drive Evap Fan Data# of Wheels (D x W) (1) 11 x 10 (1) 11 x 10
Motor Sheave VL40 X ⅝ VL40 X ⅝Blower Sheave / Belt AK66 X 1/ AX52 AK66 X 1/ AX52
Condenser Fan / CoilQuantity of Condenser Fan Motors 1 1
Horsepower - RPM ¼ - 1,075 ¼ - 1050
Fan Diameter/ # Fan Blades 22 / 4 22 / 4
Outdoor Nominal CFM 3,800 3,800
Face Area (ft²) 12.5 12.5Rows Deep/ Fins per Inch 2 / 27 2 / 27
CompressorQuantity / Type/ Stage 1 / Scroll/Single 1 / Scroll/SingleCompressor RLA / LRA 13.1 / 83.1 6.1 / 41
Electrical DataVoltage-Phase-Frequency 208/230-3-60 460-3-60
Indoor Blower HP / FLA 1.0 / 3.4 1.0 / 1.7
Max. External Static 1.0" 1.0"
Outdoor Fan HP / FLA ¼ / 1.4 ¼ / 0.7
Min. Circuit Ampacity¹ 21.2 10.0
Max. Overcurrent Protection (amps)² 30 15
Power Supply Conduit Hole 1.125 1.125Low-Voltage Conduit Hole ½" ½"
Operating Weight (lbs) 605 605Ship Weight (lbs) 630 630
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Notes• Always check the S&R plate for electrical data on the unit being installed.
Product Specifications — 4 Tons
8 www.daikinac.com SS-DSG3
Product Specifications — 4 Tons (cont.)
DSG0480901D***A*
DSG0480903D***A*
DSG0480903B***A*
DSG0480904B***A*
Cooling CapacityTotal BTU/h 48,000 48,000 47,000 47,000
Sensible BTU/h 35,520 35,520 35,000 35,000
SEER / EER 14 / 12 14 / 12 14 / 11.8 14 / 11.8
Decibels 78 78 78 78AHRI Reference #s 9967132 9967135 9952115 9952121
Heating CapacityHigh Input / Output BTU/h 92 / 75 92 / 74 92 / 74 92 / 74
Low Input / Output BTU/h 69 / 56 69 / 55 69 / 55 69 / 55
Thermal Efficiency (T.E.) ---- 80 80 80
Annual Fuel Utilization Efficiency (AFUE) 81 ---- ---- ----Temperature Rise Range (°F) Hi / Low 25-50/ 15-45 30-60 / 15-45 30-60 / 15-45 30-60 / 15-45
No. of Burners 4 4 4 4
Evaporator Motor / CoilMotor Type Direct Drive Direct Drive Belt Drive Belt Drive
Indoor Nominal CFM 1,600 1,600 1,600 1,600
Motor Speed Tap (Cooling) LOW LOW --- --
Indoor Motor FLA (Cooling) 2.80 2.80 3.4 1.7
Horsepower - RPM ¾ -1,025 ¾ -1,025 1.0 / 1,725 1.0 / 1,725
Piston Size (Cooling) 0.076 0.076 0.074 0.074
Filter Size (Qty) (4) 14" x 20" x 2" (4) 14" x 20" x 2" (4)14 x 20 x 2 (4)14" x 20" x 2"
Drain Size (NPT) ¾" ¾" ¾" ¾"
R-410A Refrigerant Charge Cir #1 (oz.) 110 110 111 111
Evaporator Coil Face Area (ft²) 7.8 7.8 7.8 7.8Rows Deep / Fins per Inch 4 / 16 4 / 16 4 / 16 4 / 16
Belt Drive Evap Fan Data# of Wheels (D x W) ---- ---- (1) 11 x 10 (1) 11 x 10
Motor Sheave ---- ---- VL40 X ⅝ VL40 X ⅝Blower Sheave / Belt ---- ---- AK66 X 1/ AX52 AK66 X 1/ AX52
Condenser Fan / CoilQuantity of Condenser Fan Motors 1 1 1 1
Horsepower - RPM ¼ - 1,075 ¼ - 1,075 ¼ - 1,075 ¼ - 1050
Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4
Outdoor Nominal CFM 3,800 3,800 3,800 3,800
Face Area (ft²) 12.5 12.5 12.5 12.5Rows Deep/ Fins per Inch 2 / 27 2 / 27 2 / 27 2 / 27
CompressorQuantity / Type/ Stage 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / SingleCompressor RLA / LRA 19.9 / 109 13.1/ 83.1 13.1 / 83.1 6.1 / 41
Electrical DataVoltage-Phase-Frequency 208/230-1-60 208/230-3-60 208/230-3-60 460-3-60
Indoor Blower HP / FLA ¾ / 2.8 ¾ / 2.8 1.0 / 3.4 1.0 / 1.7
Max. External Static 0.5" 0.5" 1.0" 1.0"
Outdoor Fan HP / FLA 1.40 1.40 1.40 0.70
Min. Circuit Ampacity¹ 29 / 29 20.6 / 20.6 21.2 / 21.2 10
Max. Overcurrent Protection (amps)² 45 / 45 30 / 30 30 / 30 15
Power Supply Conduit Hole 1.125" 1.125" 1.125 1.125Low-Voltage Conduit Hole ½" ½" ½" ½"
Operating Weight (lbs) 610 610 610 610Ship Weight (lbs) 635 635 635 635
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Notes• Always check the S&R plate for electrical data on the unit being installed.
SS-DSG3 www.daikinac.com 9
Product Specifications — 4 Tons (cont.)
DSG0481151D***A*
DSG0481153D***A*
DSG0481153B***A*
DSG0481154B***A*
DSG0481157B***A*
Cooling CapacityTotal BTU/h 48,000 48,000 47,000 47,000 47,000
Sensible BTU/h 35,520 35,520 35,000 35,000 35,000
SEER / EER 14 / 12 14 / 12 14 / 11.8 14 / 11.8 14 / 11.8
Decibels 78 78 78 78 78AHRI Reference #s 9967132 9967135 9952115 9952121 9952127
Heating CapacityHigh Input / Output BTU/h 115 / 93 115 / 92 115 / 92 115 / 92 115 / 92
Low Input / Output BTU/h 86 / 70 89 / 69 89 / 69 89 / 69 89 / 69
Thermal Efficiency (T.E.) ---- 80 80 80 80
Annual Fuel Utilization Efficiency (AFUE) 81 ---- ---- ---- ----Temperature Rise Range (°F) Hi / Low 40-70 / 25-55 40-70 / 25-55 40-70 / 25-55 40-70 / 25-55 40-70 / 25-55
No. of Burners 5 5 5 5 5
Evaporator Motor / CoilMotor Type Direct Drive Direct Drive Belt Drive Belt Drive Belt Drive
Indoor Nominal CFM 1,600 1,600 1,600 1,600 1,600
Motor Speed Tap (Cooling) LOW LOW -- -- --
Indoor Motor FLA (Cooling) 2.80 2.80 3.4 1.7 2.3
Horsepower - RPM ¾ -1,025 ¾ -1,025 1.0 / 1,725 1.0 / 1,725 1.5 / 1,725
Piston Size (Cooling) 0.076 0.076 0.074 0.074 0.074
Filter Size (Qty) (4) 14" x 20" x 2" (4) 14" x 20" x 2" (4)14" x 20" x 2" (4)14" x 20" x 2" (4)14" x 20" x 2"
Drain Size (NPT) ¾" ¾" ¾" ¾" ¾"
R-410A Refrigerant Charge Cir #1 (oz.) 110 110 111 111 111
Evaporator Coil Face Area (ft²) 7.8 7.8 7.8 7.8 7.8Rows Deep / Fins per Inch 4 / 16 4 / 16 4 / 16 4 / 16 4 / 16
Belt Drive Evap Fan Data# of Wheels (D x W) ---- ---- (1) 11 x 10 (1) 11 x 10 (1) 11 x 10
Motor Sheave ---- ---- VL40 X ⅝ VL40 X ⅝ VL40 X ⅝Blower Sheave / Belt ---- ---- AK66 X 1/ AX52 AK66 X 1/ AX52 AK66 X 1/ AX52
Condenser Fan / CoilQuantity of Condenser Fan Motors 1 1 1 1 1
Horsepower - RPM ¼ - 1,075 ¼ - 1,075 ¼ - 1,075 ¼ - 1050 ¼ - 1050
Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4 22 / 4
Outdoor Nominal CFM 3,800 3,800 3,800 3,800 3,800
Face Area (ft²) 12.5 12.5 12.5 12.5 12.5Rows Deep/ Fins per Inch 2 / 27 2 / 27 2 / 27 2 / 27 2 / 27
CompressorQuantity / Type/ Stage 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / SingleCompressor RLA / LRA 19.9 / 109 13.1/ 83.1 13.1 / 83.1 6.1 / 41.0 4.4 / 33.0
Electrical DataVoltage-Phase-Frequency 208/230-1-60 208/230-3-60 208/230-3-60 460-3-60 575-3-60
Indoor Blower HP / FLA ¾ / 2.8 ¾ / 2.8 1.0 / 3.4 1.0 / 1.7 1.5 / 2.3
Max. External Static 0.5" 0.5" 1.0" 1.0" 1.0"
Outdoor Fan HP / FLA 1.40 1.40 1.40 0.70 0.55
Min. Circuit Ampacity¹ 29 / 29 20.6 / 20.6 21.2 / 21.2 10 8.3
Max. Overcurrent Protection (amps)² 45 / 45 30 / 30 30 / 30 15 15
Power Supply Conduit Hole 1.125" 1.125" 1.125 1.125 1.125Low-Voltage Conduit Hole ½" ½" ½" ½" ½"
Operating Weight (lbs) 615 615 615 615 615Ship Weight (lbs) 640 640 640 640 640
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Notes• Always check the S&R plate for electrical data on the unit being installed.
10 www.daikinac.com SS-DSG3
Product Specifications — 5 Tons
DSG0600901D***A*
DSG0600903D***A*
DSG0600903B***A*
DSG0600904B***A*
Cooling CapacityTotal BTU/h 58,000 58,000 58,000 58,000
Sensible BTU/h 42,340 42,340 42,800 42,800
SEER / EER 14 / 11.6 14 / 11.6 14 / 11.6 14 / 11.6
Decibels 78 78 78 78AHRI Reference #s 9967133 9967136 9952116 9952122
Heating CapacityHigh Input / Output BTU/h 92 / 75 92 / 74 92 / 74 92 / 74
Low Input / Output BTU/h 69 / 56 69 / 55 69 / 55 69 / 55
Thermal Efficiency (T.E.) ---- 80 80 80
Annual Fuel Utilization Efficiency (AFUE) 81 ---- ---- ----Temperature Rise Range (°F) Hi / Low 25-55/20-50 20-50/15-45 20-50 / 15-45 20-50 / 15-45
No. of Burners 4 4 4 4
Evaporator Motor / CoilMotor Type Direct Drive Direct Drive Belt Drive Belt Drive
Indoor Nominal CFM 1,800 1,800 1,800 1,800
Motor Speed Tap (Cooling) T3 T3 ---- ----
Indoor Motor FLA (Cooling) 6.90 6.90 3.2 1.5
Horsepower - RPM 1 - 1,050 1 - 1,050 1 - 1760 1 - 1760
Piston Size (Cooling) 0.086 0.086 0.086 0.086
Filter Size (Qty) (4) 14" x 20" x 2" (4) 14" x 20" x 2" (4) 14" x 20" x 2" (4) 14" x 20" x 2"
Drain Size (NPT) ¾" ¾" ¾" ¾"
R-410A Refrigerant Charge Cir #1 (oz.) 100 100 100 100
Evaporator Coil Face Area (ft²) 7.8 7.8 7.8 7.8Rows Deep / Fins per Inch 4 / 16 4 / 16 4 / 16 4 / 16
Belt Drive Evap Fan Data# of Wheels (D x W) ---- ---- 1 (11" x 10") 1 (11" x 10")
Motor Sheave ---- ---- VL40 x ⅞ VL40 x ⅞Blower Sheave / Belt ---- ---- AK61 x 1/ AX52 AK61 x 1/ AX52
Condenser Fan / CoilQuantity of Condenser Fan Motors 1 1 1 1
Horsepower - RPM ¼ - 1,075 ¼ - 1,075 ¼ - 1,075 ¼ - 1,075
Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4
Outdoor Nominal CFM 3,800 3,800 3,800 3,800
Face Area (ft²) 13 13 13 13Rows Deep/ Fins per Inch 2 / 27 2 / 27 2 / 27 2 / 27
CompressorQuantity / Type/ Stage 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / SingleCompressor RLA / LRA 26.4 / 134.0 16.0 / 110.0 16.0 / 110.0 7.8 / 52
Electrical DataVoltage-Phase-Frequency 208/230-1-60 208/230-3-60 208/230-3-60 460-3-60
Indoor Blower HP / FLA 1.0 / 6.9 1.0 / 6.9 1.0 / 3.2 1.0 / 1.5
Max. External Static 0.9" 0.9" 1.0" 1.0"
Outdoor Fan HP / FLA ¼ / 1.40 ¼ / 1.40 ¼ / 1.40 ¼ / 0.7
Min. Circuit Ampacity¹ 41.3 / 41.3 28.3 / 28.3 24.6 / 24.6 11.9
Max. Overcurrent Protection (amps)² 60 / 60 40 / 40 40 / 40 15
Power Supply Conduit Hole 1.125" 1.125" 1.125 1.125Low-Voltage Conduit Hole ½" ½" ½" ½"
Operating Weight (lbs) 610 610 610 610Ship Weight (lbs) 635 635 635 635
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Notes• Always check the S&R plate for electrical data on the unit being installed.
SS-DSG3 www.daikinac.com 11
DSG0601153B***A*
DSG0601154B***A*
Cooling CapacityTotal BTU/h 58,000 58,000
Sensible BTU/h 43,200 43,200
SEER / EER 14 / 11.6 14 / 11.6
Decibels 78 78AHRI Reference #s 9952116 9952122
Heating CapacityHigh Input / Output BTU/h 115 / 92 115 / 92
Low Input / Output BTU/h 86 / 69 86 / 69
Thermal Efficiency (T.E.) 80 80
Annual Fuel Utilization Efficiency (AFUE) ---- ----Temperature Rise Range (°F) Hi / Low 35-65 / 25-55 35-65 / 25-55
No. of Burners 5 5
Evaporator Motor / CoilMotor Type Belt Drive Belt Drive
Indoor Nominal CFM 1,800 1,800
Motor Speed Tap (Cooling) ---- ----
Indoor Motor FLA (Cooling) 3.2 - 3.0 1.5
Horsepower - RPM 1.0 - 1760 1.0 - 1760
Piston Size (Cooling) 0.086 0.086
Filter Size (") (4) 14" x 20" x 2" (4) 14" x 20" x 2"
Drain Size (NPT) ¾" ¾"
R-410A Refrigerant Charge Cir #1 (oz.) 100 100
Evaporator Coil Face Area (ft²) 7.8 7.8Rows Deep / Fins per Inch 4 / 16 4 / 16
Belt Drive Evap Fan Data# of Wheels (D x W) 1 (11" x 10") 1 (11" x 10")
Motor Sheave VL40 x ⅞ VL40 x ⅞Blower Sheave / Belt AK61 X 1/ AX52 AK61 X 1/ AX52
Condenser Fan / CoilQuantity of Condenser Fan Motors 1 1
Horsepower - RPM ¼ - 1,075 ¼ - 1,075
Fan Diameter/ # Fan Blades 22 / 4 22 / 4
Outdoor Nominal CFM 3,800 3,800
Face Area (ft²) 13 13Rows Deep/ Fins per Inch 2 / 27 2 / 27
CompressorQuantity / Type/ Stage 1 / Scroll/Single 1 / Scroll/SingleCompressor RLA / LRA 16 .0/ 110.0 7.8 / 52.0
Electrical DataVoltage-Phase-Frequency 208/230-3-60 460-3-60
Indoor Blower HP / FLA 1.0 / 3.2 1.0 / 1.5
Max. External Static 1.0" 1.0"
Outdoor Fan HP / FLA ¼ / 1.40 ¼ / 0.7
Min. Circuit Ampacity¹ 24.6 12
Max. Overcurrent Protection (amps)² 40 15
Power Supply Conduit Hole 1.125" 1.125"Low-Voltage Conduit Hole ½" ½"
Operating Weight (lbs) 619 619Ship Weight (lbs) 644 644
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Notes• Always check the S&R plate for electrical data on the unit being installed.
Product Specifications — 5 Tons (cont.)
12 www.daikinac.com SS-DSG3
Product Specifications — 5 Tons (cont.)
DSG0601401D***A*
DSG0601403D***A*
DSG0601403B***A*
DSG0601404B***A*
DSG0601407B***A*
Cooling CapacityTotal BTU/h 58,000 58,000 58,000 58,000 58,000
Sensible BTU/h 42,340 42,340 43,200 43,200 42,500
SEER / EER 14 / 11.6 14 / 11.6 14 / 11.6 14 / 11.6 14 / 11.6
Decibels 78 78 78 78 78AHRI Reference #s 9967133 9967136 9952116 9952122 9952128
Heating CapacityHigh Input / Output BTU/h 138 / 112 138 /110 138 /110 138 /110 138 /110
Low Input / Output BTU/h 104 / 84 103 / 83 103 / 83 103 / 83 103 / 83
Thermal Efficiency (T.E.) ---- 80 80 80 80
Annual Fuel Utilization Efficiency (AFUE) 81 ---- ---- ---- ----Temperature Rise Range (°F) Hi / Low 35-65 / 25 -55 35-65 / 25 -55 35-65 / 25-55 35-65 / 25-55 35-65 / 25-55
No. of Burners 6 6 6 6 6
Evaporator Motor / CoilMotor Type Direct Drive Direct Drive Belt Drive Belt Drive Belt Drive
Indoor Nominal CFM 1,800 1,800 1,800 1,800 1,800
Motor Speed Tap (Cooling) T3 T3 ---- ---- ----
Indoor Motor FLA (Cooling) 6.90 6.90 3.2 1.5 1.2
Horsepower - RPM 1.0 - 1,050 1.0 - 1,050 1.0 - 1760 1.0 - 1760 1.0 - 1760
Piston Size (Cooling) 0.086 0.086 0.086 0.086 0.086
Filter Size (") (4) 14" x 20" x 2" (4) 14" x 20" x 2" (4) 14" x 20" x 2" (4) 14" x 20" x 2" (4) 14" x 20" x 2"
Drain Size (NPT) ¾" ¾" ¾" ¾" ¾"
R-410A Refrigerant Charge Cir #1 (oz.) 100 100 100 100 100
Evaporator Coil Face Area (ft²) 7.8 7.8 7.8 7.8 7.8Rows Deep / Fins per Inch 4 / 16 4 / 16 4 / 16 4 / 16 4 / 16
Belt Drive Evap Fan Data# of Wheels (D x W) ---- ---- 1 (11" x 10") 1 (11" x 10") 1 (11" x 10")
Motor Sheave ---- ---- VL40 x ⅞ VL40 x ⅞ VL40 x ⅞Blower Sheave / Belt ---- ---- AK61 X 1/ AX52 AK61 X 1/ AX52 AK61 X 1/ AX52
Condenser Fan / CoilQuantity of Condenser Fan Motors 1 1 1 1 1
Horsepower - RPM ¼ - 1,075 ¼ - 1,075 ¼ - 1,075 ¼ - 1,075 ¼ - 1,075
Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4 22 / 4
Outdoor Nominal CFM 3,800 3,800 3,800 3,800 3,800
Face Area (ft²) 13 13 13 13 13Rows Deep/ Fins per Inch 2 / 27 2 / 27 2 / 27 2 / 27 2 / 27
CompressorQuantity / Type/ Stage 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / SingleCompressor RLA / LRA 26.4 / 134.0 16.0 / 110.0 16 .0/ 110.0 7.8 / 52.0 5.7 / 38.9
Electrical DataVoltage-Phase-Frequency 208/230-1-60 208/230-3-60 208/230-3-60 460-3-60 575-3-60
Indoor Blower HP / FLA 1.0 / 6.9 1.0 / 6.9 1.0 / 3.2 - 3.0 1.0 / 1.5 1.0 / 1.2
Max. External Static 0.9" 0.9" 1.0" 1.0" 1.0"
Outdoor Fan HP / FLA ¼ / 1.40 ¼ / 1.40 ¼ / 1.40 ¼ / 0.7 ¼ / 0.55
Min. Circuit Ampacity¹ 41.3 / 41.3 28.3 / 28.3 24.6 / 24.6 11.9 8.9
Max. Overcurrent Protection (amps)² 60 / 60 40 / 40 40 / 40 15 15
Power Supply Conduit Hole 1.125" 1.125" 1.125" 1.125" 1.125"Low-Voltage Conduit Hole ½" ½" ½" ½" ½"
Operating Weight (lbs) 620 620 620 620 620Ship Weight (lbs) 645 645 645 645 645
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.² May use fuses or HACR-type circuit breakers of the same size as noted.Notes• Always check the S&R plate for electrical data on the unit being installed.
SS-DSG3 www.daikinac.com 13
Expanded Cooling Data — 3 Tons
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
70
1350
MBh
36.7
38.1
41.7
-35
.937
.240
.8-
35.0
36.3
39.8
-34
.235
.438
.8-
32.5
33.7
36.9
-30
.131
.234
.2-
S/T
0.75
0.63
0.44
-0.
780.
650.
45-
0.80
0.67
0.46
-0.
830.
690.
48-
0.86
0.72
0.50
-0.
860.
720.
50-
Del
ta T
1916
12-
1917
13-
1917
13-
1917
13-
1916
12-
1815
12-
KW2.
462.
512.
58-
2.63
2.69
2.77
-2.
792.
852.
93-
2.93
2.99
3.08
-3.
043.
103.
20-
3.14
3.21
3.31
-AM
PS7.
37.
57.
7-
7.9
8.0
8.3
-8.
58.
78.
9-
9.0
9.2
9.5
-9.
69.
810
.1-
10.1
10.3
10.6
-H
I PR
237
255
270
-26
628
730
3-
303
326
344
-34
537
139
2-
388
418
441
-42
946
148
7-
LO P
R11
211
913
0-
118
125
137
-12
313
014
2-
129
137
149
-13
514
315
7-
139
148
162
-
1200
MBh
35.7
37.0
40.5
-34
.836
.139
.6-
34.0
35.3
38.6
-33
.234
.437
.7-
31.5
32.7
35.8
-29
.230
.333
.2-
S/T
0.72
0.60
0.42
-0.
740.
620.
43-
0.76
0.64
0.44
-0.
790.
660.
46-
0.82
0.68
0.47
-0.
820.
690.
48-
Del
ta T
2017
13-
2017
13-
2017
13-
2017
13-
2017
13-
1816
12-
KW2.
442.
492.
56-
2.61
2.67
2.75
-2.
772.
822.
91-
2.90
2.96
3.05
-3.
023.
083.
18-
3.12
3.18
3.28
-AM
PS7.
37.
47.
7-
7.8
8.0
8.2
-8.
48.
68.
9-
9.0
9.2
9.4
-9.
59.
710
.0-
10.0
10.2
10.6
-H
I PR
235
253
267
-26
428
430
0-
300
323
341
-34
236
838
8-
384
413
437
-42
445
748
2-
LO P
R11
011
812
8-
117
124
136
-12
112
914
1-
127
136
148
-13
414
215
5-
138
147
160
-
1050
MBh
32.9
34.1
37.4
-32
.233
.336
.5-
31.4
32.5
35.7
-30
.631
.734
.8-
29.1
30.2
33.0
-27
.027
.930
.6-
S/T
0.69
0.58
0.40
-0.
720.
600.
42-
0.74
0.61
0.43
-0.
760.
630.
44-
0.79
0.66
0.46
-0.
800.
660.
46-
Del
ta T
2017
13-
2017
13-
2018
13-
2018
13-
2017
13-
1916
12-
KW2.
392.
432.
50-
2.56
2.61
2.68
-2.
702.
762.
84-
2.84
2.89
2.98
-2.
953.
013.
10-
3.04
3.11
3.20
-AM
PS7.
17.
37.
5-
7.6
7.8
8.0
-8.
28.
48.
6-
8.7
8.9
9.2
-9.
29.
49.
7-
9.7
10.0
10.3
-H
I PR
228
245
259
-25
627
529
1-
291
313
331
-33
135
637
6-
373
401
423
-41
244
346
8-
LO P
R10
711
412
4-
113
120
131
-11
812
513
7-
124
131
144
-13
013
815
0-
134
143
156
-
75
1350
MBh
37.4
38.5
41.6
44.7
36.5
37.6
40.7
43.7
35.6
36.7
39.7
42.6
34.8
35.8
38.7
41.6
33.0
34.0
36.8
39.5
30.6
31.5
34.1
36.6
S/T
0.86
0.77
0.58
0.37
0.89
0.79
0.60
0.39
0.91
0.81
0.62
0.40
0.94
0.84
0.64
0.41
0.97
0.87
0.66
0.42
0.98
0.88
0.67
0.43
Del
ta T
2220
1611
2220
1711
2220
1712
2220
1712
2220
1711
2019
1511
KW2.
482.
532.
602.
682.
652.
712.
792.
872.
812.
872.
963.
052.
953.
013.
103.
203.
073.
133.
233.
333.
173.
233.
343.
44AM
PS7.
47.
67.
88.
07.
98.
18.
48.
68.
68.
89.
09.
39.
19.
39.
69.
99.
69.
910
.210
.510
.210
.410
.711
.1H
I PR
240
258
272
284
269
289
306
319
306
329
348
363
348
375
396
413
392
422
445
465
433
466
492
513
LO P
R11
312
013
113
911
912
713
814
712
413
214
415
313
013
815
116
113
614
515
816
914
115
016
417
4
1200
MBh
36.3
37.4
40.4
43.4
35.4
36.5
39.5
42.4
34.6
35.6
38.5
41.4
33.7
34.7
37.6
40.4
32.1
33.0
35.7
38.3
29.7
30.6
33.1
35.5
S/T
0.82
0.73
0.55
0.36
0.85
0.76
0.57
0.37
0.87
0.78
0.59
0.38
0.90
0.80
0.61
0.39
0.93
0.83
0.63
0.40
0.94
0.84
0.63
0.41
Del
ta T
2321
1712
2321
1712
2321
1712
2321
1712
2321
1712
2120
1611
KW2.
462.
512.
582.
662.
632.
692.
772.
852.
792.
852.
933.
022.
932.
993.
083.
183.
043.
113.
203.
303.
143.
213.
313.
42AM
PS7.
37.
57.
78.
07.
98.
18.
38.
68.
58.
78.
99.
39.
09.
29.
59.
99.
69.
810
.110
.410
.110
.310
.611
.0H
I PR
237
255
270
281
266
287
303
316
303
326
344
359
345
371
392
409
388
418
441
460
429
461
487
508
LO P
R11
211
913
013
811
812
513
714
612
313
014
215
212
913
714
915
913
514
415
716
714
014
816
217
3
1050
MBh
33.5
34.5
37.3
40.0
32.7
33.7
36.4
39.1
31.9
32.9
35.6
38.2
31.1
32.1
34.7
37.3
29.6
30.5
33.0
35.4
27.4
28.2
30.5
32.8
S/T
0.79
0.70
0.53
0.34
0.82
0.73
0.55
0.36
0.84
0.75
0.57
0.36
0.86
0.77
0.58
0.38
0.90
0.80
0.61
0.39
0.90
0.81
0.61
0.39
Del
ta T
2321
1712
2322
1812
2322
1812
2422
1812
2321
1812
2220
1611
KW2.
412.
452.
522.
602.
582.
632.
702.
792.
732.
782.
862.
952.
862.
923.
013.
102.
973.
033.
133.
223.
073.
133.
233.
33AM
PS7.
27.
37.
57.
87.
77.
98.
18.
48.
38.
58.
79.
08.
89.
09.
39.
69.
39.
59.
810
.29.
810
.110
.410
.7H
I PR
230
248
262
273
258
278
294
306
294
316
334
348
335
360
380
397
376
405
428
446
416
448
473
493
LO P
R10
811
512
613
411
412
213
314
111
912
613
814
712
513
314
515
413
113
915
216
213
514
415
716
7ID
B =
Ente
ring
Indo
or D
ry B
ulb
Tem
pera
ture
Shad
ed a
rea
refle
cts
ACCA
(TVA
) Rati
ng c
ondi
tions
kW =
Tot
al s
yste
m p
ower
Hig
h an
d lo
w p
ress
ures
are
mea
sure
d at
the
liqui
d an
d su
ction
ser
vice
val
ves.
Amps
= o
utdo
or u
nit a
mps
(com
p.+f
an)
14 www.daikinac.com SS-DSG3
Expanded Cooling Data — 3 Tons (cont.)
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
80
1350
MBh
38.0
38.9
41.5
44.4
37.1
38.0
40.6
43.3
36.3
37.1
39.6
42.3
35.4
36.1
38.6
41.3
33.6
34.3
36.7
39.2
31.1
31.8
34.0
36.3
S/T
0.94
0.88
0.72
0.54
1.00
0.91
0.74
0.56
1.00
0.94
0.76
0.57
1.00
0.97
0.79
0.59
1.00
1.00
0.82
0.61
1.00
1.00
0.82
0.62
Del
ta T
2423
2016
2524
2116
2524
2116
2424
2117
2323
2016
2122
1915
KW2.
502.
552.
622.
702.
672.
732.
812.
902.
832.
892.
983.
072.
973.
033.
133.
233.
093.
153.
253.
363.
193.
263.
363.
47AM
PS7.
57.
67.
98.
18.
08.
28.
48.
78.
68.
89.
19.
49.
29.
49.
710
.09.
710
.010
.310
.610
.310
.510
.811
.2H
I PR
242
261
275
287
272
292
309
322
309
333
351
366
352
379
400
417
396
426
450
469
437
471
497
519
LO P
R11
412
113
214
112
012
814
014
912
513
314
515
513
114
015
316
213
814
616
017
014
215
116
517
6
1200
MBh
36.9
37.7
40.3
43.1
36.1
36.9
39.4
42.1
35.2
36.0
38.4
41.1
34.3
35.1
37.5
40.1
32.6
33.3
35.6
38.1
30.2
30.9
33.0
35.3
S/T
0.90
0.84
0.68
0.51
0.93
0.87
0.71
0.53
0.95
0.89
0.73
0.54
0.98
0.92
0.75
0.56
1.00
0.96
0.78
0.58
1.00
0.96
0.78
0.59
Del
ta T
2524
2117
2625
2117
2625
2117
2625
2217
2524
2117
2323
2016
KW2.
482.
532.
602.
682.
652.
712.
792.
872.
812.
872.
963.
052.
953.
013.
103.
203.
073.
133.
233.
333.
173.
233.
343.
44AM
PS7.
47.
67.
88.
07.
98.
18.
48.
68.
68.
89.
09.
39.
19.
39.
69.
99.
69.
910
.210
.510
.210
.410
.711
.1H
I PR
240
258
272
284
269
290
306
319
306
329
348
363
348
375
396
413
392
422
446
465
433
466
492
513
LO P
R11
312
013
113
911
912
713
814
712
413
214
415
313
013
815
116
113
614
515
816
914
115
016
417
4
1050
MBh
34.1
34.8
37.2
39.8
33.3
34.0
36.3
38.8
32.5
33.2
35.5
37.9
31.7
32.4
34.6
37.0
30.1
30.8
32.9
35.1
27.9
28.5
30.5
32.6
S/T
0.86
0.81
0.66
0.49
0.90
0.84
0.68
0.51
0.92
0.86
0.70
0.52
0.95
0.89
0.72
0.54
0.98
0.92
0.75
0.56
0.99
0.93
0.76
0.57
Del
ta T
2625
2117
2625
2217
2625
2217
2625
2218
2625
2217
2423
2016
KW2.
422.
472.
542.
622.
592.
652.
732.
812.
752.
802.
892.
982.
882.
943.
033.
122.
993.
063.
153.
253.
093.
163.
263.
36AM
PS7.
27.
47.
67.
97.
77.
98.
28.
48.
48.
58.
89.
18.
99.
19.
49.
79.
49.
69.
910
.39.
910
.110
.510
.8H
I PR
233
250
264
276
261
281
297
309
297
319
337
352
338
364
384
401
380
409
432
451
420
452
477
498
LO P
R10
911
612
713
511
612
313
414
312
012
813
914
912
613
414
615
613
214
115
416
313
714
515
916
9
85
1350
MBh
38.7
39.4
41.3
44.1
37.8
38.5
40.3
43.0
36.9
37.6
39.4
42.0
36.0
36.7
38.4
41.0
34.2
34.9
36.5
38.9
31.7
32.3
33.8
36.1
S/T
0.98
0.95
0.86
0.70
1.00
0.98
0.89
0.72
1.00
1.00
0.91
0.74
1.00
1.00
0.94
0.76
1.00
1.00
0.98
0.79
1.00
1.00
0.98
0.80
Del
ta T
2626
2421
2626
2421
2526
2421
2525
2521
2324
2421
2222
2320
KW2.
512.
562.
642.
722.
692.
752.
832.
922.
852.
913.
003.
102.
993.
063.
153.
253.
113.
183.
283.
383.
223.
293.
393.
50AM
PS7.
57.
77.
98.
28.
18.
38.
58.
88.
78.
99.
29.
59.
39.
59.
810
.19.
810
.010
.410
.710
.410
.610
.911
.3H
I PR
245
263
278
290
274
295
312
325
312
336
355
370
355
383
404
421
400
430
454
474
442
476
502
524
LO P
R11
512
213
414
212
112
914
115
012
613
414
715
613
314
115
416
413
914
816
117
214
415
316
717
8
1200
MBh
37.6
38.3
40.1
42.8
36.7
37.4
39.2
41.8
35.8
36.5
38.2
40.8
34.9
35.6
37.3
39.8
33.2
33.8
35.4
37.8
30.8
31.3
32.8
35.0
S/T
0.94
0.91
0.82
0.66
0.97
0.94
0.85
0.69
1.00
0.96
0.87
0.71
1.00
0.99
0.90
0.73
1.00
1.00
0.93
0.76
1.00
1.00
0.94
0.76
Del
ta T
2727
2522
2727
2522
2727
2522
2727
2622
2526
2522
2424
2420
KW2.
502.
552.
622.
702.
672.
732.
812.
902.
832.
892.
983.
072.
973.
033.
133.
233.
093.
153.
253.
363.
193.
263.
363.
47AM
PS7.
57.
67.
98.
18.
08.
28.
48.
78.
68.
89.
19.
49.
29.
49.
710
.09.
710
.010
.310
.610
.310
.510
.811
.2H
I PR
242
261
275
287
272
292
309
322
309
333
351
366
352
379
400
417
396
426
450
469
437
471
497
519
LO P
R11
412
113
214
112
012
814
014
912
513
314
515
513
114
015
316
213
814
616
017
014
215
116
517
6
1050
MBh
34.7
35.3
37.0
39.5
33.9
34.5
36.2
38.6
33.1
33.7
35.3
37.7
32.3
32.9
34.4
36.7
30.6
31.2
32.7
34.9
28.4
28.9
30.3
32.3
S/T
0.91
0.87
0.79
0.64
0.94
0.91
0.82
0.66
0.96
0.93
0.84
0.68
0.99
0.96
0.86
0.70
1.00
0.99
0.90
0.73
1.00
1.00
0.91
0.73
Del
ta T
2727
2622
2827
2622
2827
2622
2828
2623
2727
2622
2525
2421
KW2.
442.
492.
562.
642.
612.
672.
752.
832.
772.
822.
913.
002.
902.
963.
053.
153.
023.
083.
183.
283.
123.
183.
283.
39AM
PS7.
37.
47.
77.
97.
88.
08.
28.
58.
48.
68.
99.
29.
09.
29.
49.
89.
59.
710
.010
.310
.010
.210
.610
.9H
I PR
235
253
267
278
264
284
300
312
300
323
341
355
341
367
388
405
384
413
436
455
424
457
482
503
LO P
R11
011
712
813
711
712
413
614
412
112
914
115
012
713
614
815
813
314
215
516
513
814
716
017
1ID
B =
Ente
ring
Indo
or D
ry B
ulb
Tem
pera
ture
Shad
ed a
rea
refle
cts
AHRI
Rati
ng c
ondi
tions
kW =
Tot
al s
yste
m p
ower
Hig
h an
d lo
w p
ress
ures
are
mea
sure
d at
the
liqui
d an
d su
ction
ser
vice
val
ves.
Amps
= o
utdo
or u
nit a
mps
(com
p.+f
an)
SS-DSG3 www.daikinac.com 15
Expanded Cooling Data — 4 Tons
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
70
1800
MBh
46.0
47.7
52.3
-45
.046
.651
.1-
43.9
45.5
49.9
-42
.844
.448
.6-
40.7
42.2
46.2
-37
.739
.142
.8-
S/T
0.77
0.64
0.45
-0.
800.
670.
46-
0.82
0.68
0.47
-0.
840.
700.
49-
0.88
0.73
0.51
-0.
880.
740.
51-
Del
ta T
1816
12-
1816
12-
1816
12-
1816
12-
1816
12-
1715
11-
KW3.
103.
173.
26-
3.33
3.40
3.50
-3.
533.
603.
72-
3.71
3.78
3.90
-3.
863.
944.
06-
3.99
4.07
4.20
-AM
PS8.
18.
38.
6-
8.7
8.9
9.2
-9.
49.
710
.0-
10.1
10.3
10.6
-10
.710
.911
.2-
11.3
11.5
11.9
-H
I PR
240
259
273
-27
029
030
6-
307
330
348
-34
937
639
7-
393
423
447
-43
446
749
3-
LO P
R11
211
913
0-
118
126
138
-12
313
114
3-
129
138
150
-13
514
415
7-
140
149
163
-
1600
MBh
44.7
46.3
50.8
-43
.745
.349
.6-
42.6
44.2
48.4
-41
.643
.147
.2-
39.5
40.9
44.9
-36
.637
.941
.6-
S/T
0.73
0.61
0.42
-0.
760.
640.
44-
0.78
0.65
0.45
-0.
800.
670.
47-
0.84
0.70
0.48
-0.
840.
700.
49-
Del
ta T
1916
12-
1917
13-
1917
13-
1917
13-
1916
12-
1815
12-
KW3.
083.
143.
24-
3.31
3.37
3.48
-3.
503.
583.
69-
3.68
3.75
3.87
-3.
833.
914.
03-
3.95
4.04
4.17
-AM
PS8.
18.
38.
5-
8.7
8.9
9.1
-9.
49.
69.
9-
10.0
10.2
10.5
-10
.610
.811
.2-
11.2
11.4
11.8
-H
I PR
238
256
270
-26
728
730
3-
304
327
345
-34
637
239
3-
389
419
442
-43
046
348
8-
LO P
R11
111
812
9-
117
125
136
-12
213
014
2-
128
136
149
-13
414
315
6-
139
148
161
-
1400
MBh
41.3
42.8
46.9
-40
.341
.845
.8-
39.3
40.8
44.7
-38
.439
.843
.6-
36.5
37.8
41.4
-33
.835
.038
.4-
S/T
0.71
0.59
0.41
-0.
730.
610.
42-
0.75
0.63
0.44
-0.
780.
650.
45-
0.81
0.67
0.47
-0.
810.
680.
47-
Del
ta T
1917
13-
1917
13-
1917
13-
2017
13-
1917
13-
1816
12-
KW3.
013.
073.
16-
3.23
3.30
3.39
-3.
423.
493.
60-
3.59
3.67
3.78
-3.
733.
813.
93-
3.86
3.94
4.07
-AM
PS7.
98.
08.
3-
8.5
8.6
8.9
-9.
19.
39.
6-
9.7
9.9
10.2
-10
.310
.510
.9-
10.9
11.1
11.5
-H
I PR
231
248
262
-25
927
929
4-
295
317
335
-33
536
138
1-
377
406
429
-41
744
947
4-
LO P
R10
811
512
5-
114
121
132
-11
812
613
7-
124
132
144
-13
013
815
1-
135
143
156
-
75
1800
MBh
46.8
48.2
52.2
56.0
45.7
47.1
51.0
54.7
44.6
46.0
49.8
53.4
43.6
44.8
48.5
52.1
41.4
42.6
46.1
49.5
38.3
39.5
42.7
45.8
S/T
0.87
0.78
0.59
0.38
0.91
0.81
0.61
0.39
0.93
0.83
0.63
0.40
0.96
0.86
0.65
0.42
1.00
0.89
0.67
0.43
1.00
0.90
0.68
0.44
Del
ta T
2119
1611
2119
1611
2120
1611
2120
1611
2119
1611
2018
1510
KW3.
133.
193.
293.
393.
363.
433.
533.
643.
563.
633.
753.
863.
743.
823.
944.
063.
893.
974.
104.
234.
024.
104.
244.
37AM
PS8.
28.
48.
68.
98.
89.
09.
39.
69.
59.
710
.010
.410
.110
.410
.711
.110
.811
.011
.411
.811
.411
.612
.012
.4H
I PR
243
261
276
288
272
293
310
323
310
333
352
367
353
380
401
418
397
427
451
470
439
472
498
520
LO P
R11
312
013
214
012
012
713
914
812
413
214
415
413
113
915
216
213
714
615
916
914
215
116
417
5
1600
MBh
45.5
46.8
50.7
54.4
44.4
45.7
49.5
53.1
43.3
44.6
48.3
51.8
42.3
43.5
47.1
50.6
40.2
41.4
44.8
48.1
37.2
38.3
41.5
44.5
S/T
0.83
0.75
0.56
0.36
0.86
0.77
0.59
0.38
0.89
0.79
0.60
0.39
0.91
0.82
0.62
0.40
0.95
0.85
0.64
0.41
0.96
0.86
0.65
0.42
Del
ta T
2220
1611
2220
1711
2220
1712
2220
1712
2220
1711
2019
1511
KW3.
113.
173.
263.
363.
333.
403.
503.
613.
533.
603.
723.
833.
713.
793.
904.
033.
863.
944.
064.
203.
994.
074.
204.
34AM
PS8.
18.
38.
68.
98.
78.
99.
29.
59.
49.
710
.010
.310
.110
.310
.611
.010
.710
.911
.311
.711
.311
.511
.912
.3H
I PR
240
259
273
285
270
290
306
320
307
330
349
364
349
376
397
414
393
423
447
466
434
467
493
515
LO P
R11
211
913
013
911
812
613
814
712
313
114
315
212
913
815
016
013
614
415
716
814
014
916
317
3
1400
MBh
42.0
43.2
46.8
50.2
41.0
42.2
45.7
49.0
40.0
41.2
44.6
47.9
39.0
40.2
43.5
46.7
37.1
38.2
41.3
44.4
34.3
35.4
38.3
41.1
S/T
0.80
0.72
0.54
0.35
0.83
0.75
0.56
0.36
0.85
0.76
0.58
0.37
0.88
0.79
0.60
0.38
0.92
0.82
0.62
0.40
0.92
0.83
0.63
0.40
Del
ta T
2220
1712
2221
1712
2221
1712
2321
1712
2221
1712
2119
1611
KW3.
043.
103.
193.
283.
253.
323.
423.
533.
453.
523.
633.
743.
623.
693.
813.
933.
763.
843.
974.
093.
893.
974.
104.
23AM
PS7.
98.
18.
48.
68.
58.
79.
09.
39.
29.
49.
710
.09.
810
.010
.310
.710
.410
.611
.011
.311
.011
.211
.612
.0H
I PR
233
251
265
276
262
282
297
310
298
320
338
353
339
365
385
402
381
410
433
452
421
453
479
499
LO P
R10
911
612
613
511
512
213
314
211
912
713
914
812
513
314
615
513
114
015
316
313
614
515
816
8ID
B =
Ente
ring
Indo
or D
ry B
ulb
Tem
pera
ture
Shad
ed a
rea
refle
cts
ACCA
(TVA
) Rati
ng c
ondi
tions
kW =
Tot
al s
yste
m p
ower
Hig
h an
d lo
w p
ress
ures
are
mea
sure
d at
the
liqui
d an
d su
ction
ser
vice
val
ves.
Amps
= o
utdo
or u
nit a
mps
(com
p.+f
an)
16 www.daikinac.com SS-DSG3
Expanded Cooling Data — 4 Tons (cont.)
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
80
1800
MBh
47.7
48.7
52.0
55.6
46.5
47.6
50.8
54.3
45.4
46.4
49.6
53.0
44.3
45.3
48.4
51.7
42.1
43.0
46.0
49.1
39.0
39.9
42.6
45.5
S/T
0.96
0.90
0.73
0.55
1.00
0.93
0.76
0.57
1.00
0.96
0.78
0.58
1.00
1.00
0.80
0.60
1.00
1.00
0.83
0.62
1.00
1.00
0.84
0.63
Del
ta T
2322
1916
2423
2016
2323
2016
2323
2016
2222
2016
2020
1815
KW3.
153.
223.
313.
413.
383.
453.
563.
673.
593.
663.
783.
903.
773.
853.
974.
103.
924.
004.
134.
264.
054.
144.
274.
41AM
PS8.
38.
58.
79.
08.
99.
19.
49.
79.
69.
810
.110
.510
.210
.510
.811
.210
.811
.111
.511
.911
.511
.712
.112
.5H
I PR
245
264
279
291
275
296
313
326
313
337
356
371
356
384
405
422
401
431
456
475
443
477
503
525
LO P
R11
412
213
314
112
112
914
014
912
613
414
615
513
214
015
316
313
814
716
117
114
315
216
617
7
1600
MBh
46.3
47.3
50.5
54.0
45.2
46.2
49.3
52.7
44.1
45.1
48.2
51.5
43.0
44.0
47.0
50.2
40.9
41.8
44.6
47.7
37.9
38.7
41.3
44.2
S/T
0.91
0.86
0.70
0.52
0.95
0.89
0.72
0.54
0.97
0.91
0.74
0.55
1.00
0.94
0.77
0.57
1.00
0.98
0.80
0.59
1.00
0.98
0.80
0.60
Del
ta T
2423
2016
2524
2116
2524
2116
2524
2117
2323
2016
2222
1915
KW3.
133.
193.
293.
393.
363.
433.
533.
643.
563.
633.
753.
873.
743.
823.
944.
063.
893.
974.
104.
234.
024.
104.
244.
38AM
PS8.
28.
48.
68.
98.
89.
09.
39.
69.
59.
710
.010
.410
.110
.410
.711
.110
.811
.011
.411
.811
.411
.612
.012
.4H
I PR
243
261
276
288
272
293
310
323
310
333
352
367
353
380
401
418
397
427
451
471
439
472
498
520
LO P
R11
312
013
214
012
012
713
914
812
413
214
415
413
113
915
216
213
714
615
916
914
215
116
417
5
1400
MBh
42.7
43.6
46.6
49.8
41.7
42.6
45.5
48.7
40.7
41.6
44.5
47.5
39.7
40.6
43.4
46.4
37.7
38.6
41.2
44.0
35.0
35.7
38.2
40.8
S/T
0.88
0.83
0.67
0.50
0.91
0.86
0.70
0.52
0.94
0.88
0.72
0.53
0.97
0.91
0.74
0.55
1.00
0.94
0.77
0.57
1.01
0.95
0.77
0.58
Del
ta T
2524
2116
2524
2117
2524
2117
2524
2117
2524
2117
2322
1915
KW3.
063.
123.
213.
313.
283.
353.
453.
563.
483.
553.
663.
773.
653.
723.
843.
963.
793.
884.
004.
133.
924.
004.
134.
27AM
PS8.
08.
28.
48.
78.
68.
89.
19.
49.
39.
59.
810
.19.
910
.110
.410
.810
.510
.711
.111
.411
.111
.311
.712
.1H
I PR
235
253
268
279
264
284
300
313
301
323
342
356
342
368
389
406
385
414
438
456
425
458
483
504
LO P
R11
011
712
813
611
612
313
514
412
112
814
014
912
713
514
715
713
314
115
416
413
714
616
017
0
85
1800
MBh
48.5
49.4
51.8
55.2
47.4
48.3
50.6
53.9
46.2
47.1
49.4
52.7
45.1
46.0
48.2
51.4
42.8
43.7
45.7
48.8
39.7
40.5
42.4
45.2
S/T
1.00
0.97
0.88
0.71
1.00
1.00
0.91
0.74
1.00
1.00
0.93
0.76
1.00
1.00
0.96
0.78
1.00
1.00
1.00
0.81
1.00
1.00
1.00
0.82
Del
ta T
2524
2320
2425
2320
2424
2320
2323
2420
2222
2320
2021
2219
KW3.
183.
243.
343.
443.
413.
483.
593.
703.
613.
693.
813.
933.
803.
884.
004.
133.
954.
044.
164.
304.
084.
174.
314.
45AM
PS8.
38.
58.
89.
19.
09.
29.
59.
89.
79.
910
.210
.610
.310
.610
.911
.310
.911
.211
.612
.011
.611
.812
.212
.6H
I PR
248
267
281
294
278
299
316
329
316
340
359
375
360
387
409
427
405
436
460
480
447
482
508
530
LO P
R11
612
313
414
312
213
014
215
112
713
514
715
713
314
215
516
514
014
916
217
314
415
416
817
9
1600
MBh
47.1
48.0
50.3
53.6
46.0
46.9
49.1
52.4
44.9
45.8
47.9
51.1
43.8
44.6
46.8
49.9
41.6
42.4
44.4
47.4
38.5
39.3
41.1
43.9
S/T
0.96
0.93
0.84
0.68
0.99
0.96
0.87
0.70
1.00
0.98
0.89
0.72
1.00
1.00
0.92
0.74
1.00
1.00
0.95
0.77
1.00
1.00
0.96
0.78
Del
ta T
2626
2421
2626
2421
2626
2421
2526
2521
2424
2421
2223
2320
KW3.
153.
223.
313.
413.
383.
453.
563.
673.
593.
663.
783.
903.
773.
853.
974.
103.
924.
004.
134.
264.
054.
144.
274.
41AM
PS8.
38.
58.
79.
08.
99.
19.
49.
79.
69.
810
.110
.510
.210
.510
.811
.210
.811
.111
.511
.911
.511
.712
.112
.5H
I PR
245
264
279
291
275
296
313
326
313
337
356
371
356
384
405
422
401
431
456
475
443
477
503
525
LO P
R11
412
213
314
112
112
914
014
912
613
414
615
513
214
015
316
313
814
716
117
114
315
216
617
7
1400
MBh
43.5
44.3
46.4
49.5
42.4
43.3
45.3
48.3
41.4
42.2
44.2
47.2
40.4
41.2
43.2
46.0
38.4
39.1
41.0
43.7
35.6
36.3
38.0
40.5
S/T
0.92
0.89
0.81
0.65
0.96
0.92
0.83
0.68
0.98
0.95
0.86
0.69
1.00
0.98
0.88
0.72
1.00
1.00
0.92
0.74
1.00
1.00
0.92
0.75
Del
ta T
2626
2521
2726
2521
2726
2522
2726
2522
2526
2521
2324
2320
KW3.
083.
143.
243.
333.
303.
373.
483.
583.
503.
583.
693.
803.
683.
753.
874.
003.
823.
914.
034.
163.
954.
044.
174.
30AM
PS8.
18.
28.
58.
88.
78.
99.
19.
59.
49.
69.
910
.210
.010
.210
.510
.910
.610
.811
.111
.511
.211
.411
.812
.2H
I PR
238
256
270
282
267
287
303
316
304
327
345
360
346
372
393
410
389
419
442
461
430
462
488
509
LO P
R11
111
812
913
711
712
513
614
512
213
014
115
112
813
614
915
813
414
315
616
613
914
816
117
2ID
B =
Ente
ring
Indo
or D
ry B
ulb
Tem
pera
ture
Shad
ed a
rea
refle
cts
AHRI
Rati
ng c
ondi
tions
kW =
Tot
al s
yste
m p
ower
Hig
h an
d lo
w p
ress
ures
are
mea
sure
d at
the
liqui
d an
d su
ction
ser
vice
val
ves.
Amps
= o
utdo
or u
nit a
mps
(com
p.+f
an)
SS-DSG3 www.daikinac.com 17
Expanded Cooling Data — 5 Tons
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
70
2050
MBh
57.6
59.7
65.4
-56
.358
.363
.9-
54.9
56.9
62.4
-53
.655
.660
.9-
50.9
52.8
57.8
-47
.248
.953
.6-
S/T
0.74
0.62
0.43
-0.
770.
640.
44-
0.78
0.66
0.45
-0.
810.
680.
47-
0.84
0.70
0.49
-0.
850.
710.
49-
Del
ta T
1917
13-
1917
13-
1917
13-
1917
13-
1917
13-
1816
12-
KW3.
954.
044.
17-
4.26
4.35
4.49
-4.
534.
634.
78-
4.77
4.87
5.04
-4.
975.
085.
25-
5.15
5.26
5.44
-AM
PS10
.210
.410
.7-
11.0
11.2
11.6
-11
.912
.212
.6-
12.7
13.0
13.5
-13
.513
.914
.3-
14.3
14.7
15.2
-H
I PR
257
277
292
-28
931
132
8-
328
353
373
-37
440
342
5-
421
453
478
-46
550
052
8-
LO P
R10
711
412
4-
113
120
131
-11
712
513
6-
123
131
143
-12
913
715
0-
134
142
155
-
1800
MBh
55.9
58.0
63.5
-54
.656
.662
.0-
53.3
55.3
60.6
-52
.053
.959
.1-
49.4
51.2
56.1
-45
.847
.552
.0-
S/T
0.70
0.59
0.41
-0.
730.
610.
42-
0.75
0.62
0.43
-0.
770.
650.
45-
0.80
0.67
0.46
-0.
810.
680.
47-
Del
ta T
2017
13-
2018
13-
2018
13-
2118
13-
2018
13-
1916
12-
KW3.
924.
004.
13-
4.22
4.32
4.46
-4.
494.
594.
74-
4.73
4.83
4.99
-4.
935.
045.
21-
5.10
5.22
5.39
-AM
PS10
.110
.310
.6-
10.9
11.1
11.5
-11
.812
.112
.5-
12.6
12.9
13.4
-13
.413
.714
.2-
14.2
14.6
15.1
-H
I PR
255
274
290
-28
630
832
5-
325
350
370
-37
039
942
1-
417
448
474
-46
049
552
3-
LO P
R10
611
312
3-
112
119
130
-11
612
413
5-
122
130
142
-12
813
614
9-
132
141
154
-
1550
MBh
51.6
53.5
58.6
-50
.452
.357
.3-
49.2
51.0
55.9
-48
.049
.854
.5-
45.6
47.3
51.8
-42
.343
.848
.0-
S/T
0.68
0.57
0.39
-0.
700.
590.
41-
0.72
0.60
0.42
-0.
740.
620.
43-
0.77
0.65
0.45
-0.
780.
650.
45-
Del
ta T
2118
14-
2118
14-
2118
14-
2118
14-
2118
14-
2017
13-
KW3.
833.
914.
03-
4.12
4.21
4.35
-4.
384.
484.
62-
4.61
4.71
4.87
-4.
814.
915.
08-
4.97
5.09
5.26
-AM
PS9.
810
.010
.4-
10.6
10.8
11.2
-11
.511
.812
.2-
12.3
12.6
13.0
-13
.113
.413
.8-
13.8
14.2
14.6
-H
I PR
247
266
281
-27
729
831
5-
315
339
358
-35
938
740
8-
404
435
459
-44
748
150
7-
LO P
R10
310
911
9-
108
115
126
-11
312
013
1-
118
126
137
-12
413
214
4-
128
136
149
-
75
2050
MBh
58.6
60.3
65.3
70.1
57.2
58.9
63.8
68.5
55.9
57.5
62.3
66.8
54.5
56.1
60.7
65.2
51.8
53.3
57.7
61.9
48.0
49.4
53.5
57.4
S/T
0.84
0.75
0.57
0.37
0.87
0.78
0.59
0.38
0.89
0.80
0.60
0.39
0.92
0.82
0.62
0.40
0.96
0.85
0.65
0.42
0.96
0.86
0.65
0.42
Del
ta T
2220
1711
2221
1712
2221
1712
2321
1712
2220
1712
2119
1611
KW3.
984.
074.
204.
344.
294.
394.
534.
684.
574.
674.
824.
984.
814.
925.
085.
255.
015.
135.
305.
485.
195.
315.
495.
68AM
PS10
.310
.510
.811
.211
.111
.311
.712
.112
.012
.312
.713
.212
.813
.213
.614
.113
.714
.014
.515
.014
.514
.815
.315
.9H
I PR
260
280
295
308
292
314
332
346
332
357
377
393
378
407
429
448
425
458
483
504
470
506
534
557
LO P
R10
811
512
513
411
412
113
214
111
912
613
814
712
413
214
515
413
013
915
216
113
514
415
716
7
1800
MBh
56.9
58.6
63.4
68.0
55.6
57.2
61.9
66.5
54.2
55.8
60.5
64.9
52.9
54.5
59.0
63.3
50.3
51.8
56.0
60.1
46.6
47.9
51.9
55.7
S/T
0.80
0.72
0.54
0.35
0.83
0.74
0.56
0.36
0.85
0.76
0.58
0.37
0.88
0.79
0.59
0.38
0.91
0.82
0.62
0.40
0.92
0.82
0.62
0.40
Del
ta T
2321
1812
2422
1812
2422
1812
2422
1812
2322
1812
2220
1611
KW3.
954.
044.
174.
304.
264.
354.
494.
644.
534.
634.
784.
944.
774.
885.
045.
214.
975.
085.
255.
435.
155.
265.
445.
63AM
PS10
.210
.410
.711
.111
.011
.211
.612
.011
.912
.212
.613
.112
.713
.013
.514
.013
.513
.914
.314
.914
.314
.715
.215
.8H
I PR
257
277
293
305
289
311
328
342
329
354
373
389
374
403
425
443
421
453
478
499
465
501
529
551
LO P
R10
711
412
413
211
312
013
114
011
712
513
614
512
313
114
315
212
913
715
016
013
414
215
516
5
1550
MBh
52.5
54.1
58.5
62.8
51.3
52.8
57.2
61.3
50.1
51.5
55.8
59.9
48.8
50.3
54.4
58.4
46.4
47.8
51.7
55.5
43.0
44.3
47.9
51.4
S/T
0.77
0.69
0.52
0.34
0.80
0.72
0.54
0.35
0.82
0.73
0.56
0.36
0.85
0.76
0.57
0.37
0.88
0.79
0.59
0.38
0.89
0.79
0.60
0.39
Del
ta T
2422
1813
2422
1813
2422
1813
2523
1913
2422
1813
2321
1712
KW3.
863.
944.
064.
204.
164.
254.
384.
534.
424.
514.
664.
824.
654.
754.
915.
074.
854.
965.
125.
295.
025.
135.
305.
48AM
PS9.
910
.110
.510
.810
.710
.911
.311
.711
.611
.912
.312
.712
.412
.713
.113
.613
.213
.513
.914
.514
.014
.314
.815
.3H
I PR
250
269
284
296
280
302
318
332
319
343
362
378
363
391
412
430
408
439
464
484
451
486
513
535
LO P
R10
411
012
012
811
011
712
713
511
412
113
214
112
012
713
914
812
513
314
615
513
013
815
116
0ID
B =
Ente
ring
Indo
or D
ry B
ulb
Tem
pera
ture
Shad
ed a
rea
refle
cts
ACCA
(TVA
) Rati
ng c
ondi
tions
kW =
Tot
al s
yste
m p
ower
Hig
h an
d lo
w p
ress
ures
are
mea
sure
d at
the
liqui
d an
d su
ction
ser
vice
val
ves.
Amps
= o
utdo
or u
nit a
mps
(com
p.+f
an)
18 www.daikinac.com SS-DSG3
Expanded Cooling Data — 5 Tons (cont.)
Out
door
Am
bien
t Te
mpe
ratu
re65
7585
9510
511
5En
teri
ng In
door
Wet
Bul
b Te
mpe
ratu
reID
BAi
rflo
w59
6367
7159
6367
7159
6367
7159
6367
7159
6367
7159
6367
71
80
2050
MBh
59.6
60.9
65.1
69.6
58.3
59.5
63.6
68.0
56.9
58.1
62.1
66.4
55.5
56.7
60.6
64.7
52.7
53.9
57.5
61.5
48.8
49.9
53.3
57.0
S/T
0.92
0.86
0.70
0.53
0.95
0.89
0.73
0.54
1.00
0.92
0.75
0.56
1.00
0.95
0.77
0.58
1.00
1.00
0.80
0.60
1.00
1.00
0.81
0.60
Del
ta T
2524
2116
2524
2117
2624
2117
2524
2117
2424
2116
2222
1915
KW4.
024.
104.
234.
374.
334.
424.
574.
724.
614.
714.
865.
034.
854.
965.
125.
305.
065.
175.
345.
535.
245.
355.
535.
72AM
PS10
.310
.610
.911
.311
.211
.411
.812
.312
.112
.412
.813
.313
.013
.313
.714
.213
.814
.114
.615
.214
.615
.015
.516
.1H
I PR
263
283
298
311
295
317
335
349
335
361
381
397
382
411
434
452
429
462
488
509
475
511
539
562
LO P
R10
911
612
713
511
512
313
414
212
012
713
914
812
613
414
615
613
214
015
316
313
614
515
816
9
1800
MBh
57.9
59.2
63.2
67.6
56.6
57.8
61.7
66.0
55.2
56.4
60.3
64.4
53.9
55.0
58.8
62.9
51.2
52.3
55.9
59.7
47.4
48.4
51.7
55.3
S/T
0.88
0.82
0.67
0.50
0.91
0.85
0.69
0.52
0.93
0.87
0.71
0.53
0.96
0.90
0.74
0.55
1.00
0.94
0.76
0.57
1.00
0.95
0.77
0.57
Del
ta T
2625
2217
2625
2217
2625
2218
2625
2218
2625
2217
2423
2016
KW3.
984.
074.
204.
344.
294.
394.
534.
684.
574.
674.
824.
984.
814.
925.
085.
255.
015.
135.
305.
485.
195.
315.
495.
68AM
PS10
.310
.510
.811
.211
.111
.311
.712
.112
.012
.312
.713
.212
.913
.213
.614
.113
.714
.014
.515
.014
.514
.815
.315
.9H
I PR
260
280
295
308
292
314
332
346
332
357
377
393
378
407
430
448
425
458
483
504
470
506
534
557
LO P
R10
811
512
513
411
412
113
214
111
912
613
814
712
513
214
515
413
013
915
216
113
514
415
716
7
1550
MBh
53.4
54.6
58.3
62.4
52.2
53.3
57.0
60.9
51.0
52.1
55.6
59.5
49.7
50.8
54.3
58.0
47.2
48.3
51.6
55.1
43.7
44.7
47.8
51.1
S/T
0.85
0.79
0.65
0.48
0.88
0.82
0.67
0.50
0.90
0.84
0.69
0.51
0.93
0.87
0.71
0.53
0.96
0.90
0.74
0.55
0.97
0.91
0.74
0.55
Del
ta T
2726
2218
2726
2318
2726
2318
2726
2318
2726
2218
2524
2117
KW3.
893.
974.
104.
234.
194.
284.
424.
564.
454.
554.
704.
864.
694.
794.
955.
124.
895.
005.
165.
345.
065.
175.
355.
53AM
PS10
.010
.210
.510
.910
.811
.011
.411
.811
.712
.012
.412
.812
.512
.813
.213
.713
.313
.614
.114
.614
.114
.414
.915
.5H
I PR
252
271
287
299
283
305
322
335
322
346
366
382
367
395
417
435
412
444
469
489
456
490
518
540
LO P
R10
511
112
213
011
111
812
813
711
512
213
414
212
112
814
014
912
713
514
715
713
113
915
216
2
85
2050
MBh
60.7
61.9
64.8
69.1
59.3
60.4
63.3
67.5
57.9
59.0
61.8
65.9
56.4
57.5
60.3
64.3
53.6
54.7
57.2
61.1
49.7
50.6
53.0
56.6
S/T
0.96
0.93
0.84
0.68
1.00
0.96
0.87
0.71
1.00
0.99
0.89
0.72
1.00
1.00
0.92
0.75
1.00
1.00
0.96
0.78
1.00
1.00
0.96
0.78
Del
ta T
2626
2421
2726
2521
2626
2521
2526
2522
2425
2521
2223
2320
KW4.
054.
144.
274.
414.
374.
464.
614.
764.
644.
754.
905.
074.
895.
005.
175.
345.
105.
215.
395.
575.
285.
405.
585.
77AM
PS10
.410
.711
.011
.411
.311
.511
.912
.412
.212
.513
.013
.413
.113
.413
.914
.413
.914
.314
.715
.314
.815
.115
.616
.2H
I PR
265
285
301
314
298
320
338
353
339
364
385
401
386
415
438
457
434
467
493
514
479
516
545
568
LO P
R11
011
712
813
611
612
413
514
412
112
914
015
012
713
514
815
713
314
215
516
513
814
616
017
0
1800
MBh
58.9
60.1
62.9
67.1
57.5
58.7
61.4
65.5
56.2
57.3
60.0
64.0
54.8
55.9
58.5
62.4
52.1
53.1
55.6
59.3
48.2
49.2
51.5
54.9
S/T
0.92
0.89
0.80
0.65
0.95
0.92
0.83
0.67
0.98
0.94
0.85
0.69
1.00
0.97
0.88
0.71
1.00
1.00
0.91
0.74
1.00
1.00
0.92
0.75
Del
ta T
2827
2622
2828
2623
2828
2623
2828
2623
2727
2622
2525
2421
KW4.
024.
104.
234.
374.
334.
424.
574.
724.
614.
714.
865.
034.
854.
965.
125.
305.
065.
175.
345.
535.
245.
355.
535.
72AM
PS10
.310
.610
.911
.311
.211
.411
.812
.312
.112
.412
.813
.313
.013
.313
.714
.213
.814
.114
.615
.214
.615
.015
.516
.1H
I PR
263
283
298
311
295
317
335
349
335
361
381
397
382
411
434
452
429
462
488
509
475
511
539
562
LO P
R10
911
612
713
511
512
313
414
212
012
713
914
812
613
414
615
613
214
015
316
313
614
515
816
9
1550
MBh
54.4
55.4
58.1
61.9
53.1
54.1
56.7
60.5
51.8
52.8
55.4
59.1
50.6
51.6
54.0
57.6
48.1
49.0
51.3
54.7
44.5
45.4
47.5
50.7
S/T
0.89
0.86
0.77
0.63
0.92
0.89
0.80
0.65
0.94
0.91
0.82
0.67
0.97
0.94
0.85
0.69
1.00
0.97
0.88
0.71
1.00
0.98
0.89
0.72
Del
ta T
2928
2723
2928
2723
2929
2723
2929
2723
2928
2723
2626
2522
KW3.
924.
004.
134.
264.
224.
324.
454.
604.
494.
594.
744.
904.
734.
834.
995.
164.
935.
045.
215.
385.
105.
225.
395.
58AM
PS10
.110
.310
.611
.010
.911
.111
.511
.911
.812
.112
.513
.012
.612
.913
.313
.813
.413
.714
.214
.714
.214
.615
.015
.6H
I PR
255
274
289
302
286
308
325
339
325
350
369
385
370
398
421
439
417
448
473
494
460
495
523
546
LO P
R10
611
312
313
111
211
913
013
811
612
413
514
412
213
014
215
112
813
614
815
813
214
115
416
4
IDB
= En
terin
g In
door
Dry
Bul
b Te
mpe
ratu
reSh
aded
are
a re
flect
s AH
RI R
ating
con
ditio
nskW
= T
otal
sys
tem
pow
erH
igh
and
low
pre
ssur
es a
re m
easu
red
at th
e liq
uid
and
sucti
on s
ervi
ce v
alve
s.Am
ps =
out
door
uni
t am
ps (c
omp.
+fan
)
SS-DSG3 www.daikinac.com 19
Airflow Data — 3 Tons
Standard Belt Drive — Down Shot
ESP (“ H2O)
Turns Open0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.1 --- --- --- --- --- --- --- --- 1279 0.31 1071 0.26
0.2 --- --- --- --- --- --- 1291 0.32 1124 0.28 916 0.23
0.3 --- --- --- --- --- --- 1134 0.30 969 0.25 717 0.21
0.4 --- --- --- --- 1213 0.32 977 0.29 770 0.23 --- ---
0.5 --- --- 1227 0.38 1029 0.30 773 0.26 --- --- --- ---
0.6 1283 0.43 1076 0.35 867 0.29 --- --- --- --- --- ---
0.7 1125 0.40 891 0.31 699 0.27 --- --- --- --- --- ---
0.8 949 0.37 696 0.29 --- --- --- --- --- --- --- ---
0.9 687 0.33 --- --- --- --- --- --- --- --- --- ---
1.0 634 0.30 --- --- --- --- --- --- --- --- --- ---
High-Static Belt Drive — Down Shot
ESP (“ H2O)
Turns Open0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.6 --- --- --- --- --- --- --- --- --- --- --- ---
0.7 --- --- --- --- --- --- --- --- --- --- 1222 0.40
0.8 --- --- --- --- --- --- --- --- --- --- 1117 0.39
0.9 --- --- --- --- --- --- --- --- 1221 0.46 1012 0.38
1.0 --- --- --- --- --- --- 1246 0.52 1078 0.42 869 0.35
1.1 --- --- --- --- --- --- 1126 0.49 935 0.39 725 0.33
1.2 --- --- --- --- 1268 0.56 1006 0.46 763 0.36 --- ---
1.3 --- --- 1335 0.65 1141 0.53 847 0.42 --- --- --- ---
1.4 --- --- 1212 0.62 1014 0.50 690 0.38 --- --- --- ---
1.5 1314 0.72 1090 0.58 887 0.47 --- --- --- --- --- ---
1.6 1187 0.67 922 0.53 750 0.43 --- --- --- --- --- ---
1.7 1060 0.63 753 0.49 --- --- --- --- --- --- --- ---
1.8 978 0.61 --- --- --- --- --- --- --- --- --- ---
Note: Tables represent dry coil without filter; to compensate for filter, add 0.08” to measured E.S.P. SCFM correction for wet coil = 4%.
20 www.daikinac.com SS-DSG3
Airflow Data — 3 Tons (cont.)
Standard Belt Drive — Horizontal
ESP (“ H2O)
Turns Open0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.1 --- --- --- --- --- --- --- --- --- --- 1190 0.29
0.2 --- --- --- --- --- --- --- --- 1249 0.31 1018 0.26
0.3 --- --- --- --- --- --- 1260 0.34 1077 0.28 797 0.24
0.4 --- --- --- --- 1318 0.35 1085 0.33 856 0.26 --- ---
0.5 --- --- 1334 0.41 1119 0.33 859 0.30 --- --- --- ---
0.6 1395 0.46 1170 0.38 942 0.31 --- --- --- --- --- ---
0.7 1223 0.43 968 0.34 760 0.30 --- --- --- --- --- ---
0.8 1032 0.40 756 0.31 --- --- --- --- --- --- --- ---
0.9 747 0.36 --- --- --- --- --- --- --- --- --- ---
1.0 688 0.33 --- --- --- --- --- --- --- --- --- ---
High-Static Belt Drive — Horizontal
ESP (“ H2O)
Turns Open0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.6 --- --- --- --- --- --- --- --- --- --- --- ---
0.7 --- --- --- --- --- --- --- --- --- --- --- ---
0.8 --- --- --- --- --- --- --- --- --- --- 1269 0.45
0.9 --- --- --- --- --- --- --- --- --- --- 1150 0.44
1.0 --- --- --- --- --- --- --- --- 1225 0.48 988 0.40
1.1 --- --- --- --- --- --- 1280 0.55 1063 0.44 824 0.37
1.2 --- --- --- --- --- --- 1143 0.52 867 0.40 --- ---
1.3 --- --- --- --- 1268 0.59 963 0.48 651 0.36 --- ---
1.4 --- --- 1332 0.68 1127 0.55 766 0.43 --- --- --- ---
1.5 --- --- 1198 0.64 986 0.52 --- --- --- --- --- ---
1.6 1304 0.74 1013 0.59 833 0.48 --- --- --- --- --- ---
1.7 1165 0.69 828 0.54 --- --- --- --- --- --- --- ---
1.8 1075 0.67 --- --- --- --- --- --- --- --- --- ---
Note: Tables represent dry coil without filter; to compensate for filter, add 0.08” to measured E.S.P. SCFM correction for wet coil = 4%.
SS-DSG3 www.daikinac.com 21
Airflow Data — 4 Tons
Standard Direct Drive — Horizontal Standard Direct Drive — Down Shot
CFM Static Amps Watts RPM Speed Tap CFM Static Amps Watts RPM Speed
Tap 1570 0.1 2.09 490 905
Low
1548 0.1 2.03 480 930
Low 1520 0.2 2.06 480 920 1500 0.2 2 470 9451445 0.3 1.95 460 945 1425 0.3 1.89 450 9701375 0.4 1.89 440 970 1353 0.4 1.83 430 9951295 0.5 1.81 425 995 1273 0.5 175 415 1020
1715 0.1 2.39 560 975
Med
1660 0.1 2.31 540 1020
Med
1655 0.2 2.32 545 985 1625 0.2 2.25 530 10351580 0.3 2.24 525 1005 1565 0.3 2.19 515 10401500 0.4 2.16 505 1020 1485 0.4 2.12 505 10501405 0.5 2.09 490 1035 1405 0.5 2.12 500 10551305 0.6 2.00 465 1050 1285 0.6 1.98 465 10601200 0.7 1.92 440 1065 1200 0.7 1.93 440 1070
1839 0.1 2.77 650 1030
High
1825 0.1 2.65 620 1045
High
1770 0.2 2.70 630 1040 1745 0.2 2.55 600 10601696 0.3 2.62 610 1050 1670 0.3 2.53 590 10651611 0.4 2.53 590 1060 1585 0.4 2.46 575 10701510 0.5 2.44 560 1070 1480 0.5 2.37 550 10801418 0.6 2.36 540 1085 1405 0.6 2.31 535 1090
Note: Assumes dry coil with filter in place; SCFM correction for wet coil = 4%
Airflow Data — 3 Tons (cont.)
Standard Direct Drive — Horizontal Standard Direct Drive — Down Shot
CFM Static Amps Watts RPM Speed Tap CFM Static Amps Watts RPM Speed
Tap
1280 0.1 1.54 360 755
Low
1270 0.1 1.53 355 760
Low 1215 0.2 1.5 345 800 1205 0.2 1.53 350 8101145 0.3 1.46 335 830 1145 0.3 1.49 340 8401080 0.4 1.42 325 870 1085 0.4 1.45 330 8751005 0.5 1.37 310 895 1035 0.5 1.42 320 900
1485 0.1 1.98 460 840
Med
1460 0.1 1.96 450 850
Med
1410 0.2 1.92 440 870 1380 0.2 1.89 430 8851335 0.3 1.86 425 900 1275 0.3 1.8 405 9151255 0.4 1.8 410 930 1175 0.4 1.73 400 9501170 0.5 1.75 400 950 1075 0.5 1.68 380 9651075 0.6 1.68 380 980 1005 0.6 1.63 370 1000945 0.7 1.6 360 1005 915 0.7 1.59 360 1015
1445 0.3 2.2 505 940
Med
1445 0.3 2.2 500 950
High
1365 0.4 2.14 490 960 1340 0.4 2.13 480 9751270 0.5 2.08 470 985 1275 0.5 2.07 465 10001180 0.6 2.02 460 1000 1175 0.6 2.02 455 10201050 0.7 1.92 435 1030 1040 0.7 1.92 430 1045825 0.8 1.78 400 1055 830 0.8 1.78 395 1070
Note: Assumes dry coil with filter in place; SCFM correction for wet coil = 4%
22 www.daikinac.com SS-DSG3
Airflow Data — 4 Tons (cont.)
Standard Belt Drive — Down Shot
ESP (“ H2O)
Turns Open
0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.1 --- --- --- --- --- --- 1690 0.42 1553 0.33
0.2 --- --- --- --- --- --- 1719 0.47 1548 0.39 1417 0.32
0.3 --- --- --- --- 1699 0.50 1570 0.44 1406 0.37 1258 0.30
0.4 --- --- 1742 0.53 1566 0.47 1421 0.41 1258 0.34 1095 0.27
0.5 1770 0.60 1617 0.50 1427 0.44 1278 0.38 1094 0.32 --- ---
0.6 1664 0.57 1492 0.47 1286 0.41 1127 0.36 --- --- --- ---
0.7 1558 0.54 1376 0.45 1139 0.38 935 0.32 --- --- --- ---
0.8 1415 0.50 1220 0.41 961 0.35 --- --- --- --- --- ---
0.9 1288 0.47 1054 0.38 --- --- --- --- --- --- --- ---
1.0 1121 0.43 --- --- --- --- --- --- --- --- --- ---
1.1 953 0.39 --- --- --- --- --- --- --- --- --- ---
High-Static Belt Drive — Down Shot
ESP (“ H2O)
Turns Open
0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.6 --- --- --- --- --- --- --- --- 1688 0.58 1503 0.48
0.7 --- --- --- --- --- --- 1716 0.62 1569 0.55 1398 0.46
0.8 --- --- --- --- --- --- 1613 0.59 1450 0.51 1268 0.43
0.9 --- --- --- --- 1702 0.67 1510 0.56 1331 0.48 1138 0.40
1.0 --- --- --- --- 1589 0.64 1412 0.53 1190 0.45 984 0.37
1.1 --- --- 1751 0.75 1477 0.60 1281 0.50 1052 0.42 --- ---
1.2 1755 0.85 1605 0.70 1364 0.57 1133 0.46 --- --- --- ---
1.3 1640 0.80 1459 0.66 1224 0.53 983 0.43 --- --- --- ---
1.4 1525 0.76 1313 0.61 1083 0.49 --- --- --- --- --- ---
1.5 1410 0.72 1192 0.57 --- --- --- --- --- --- --- ---
1.6 1276 0.67 1033 0.53 --- --- --- --- --- --- --- ---
1.7 1137 0.63 --- --- --- --- --- --- --- --- --- ---
1.8 1008 0.59 --- --- --- --- --- --- --- --- --- ---
Note: Tables represent dry coil without filter; to compensate for filter, add 0.08” to measured E.S.P. SCFM correction for wet coil = 4%.
SS-DSG3 www.daikinac.com 23
Airflow Data — 4 Tons (cont.)
Standard Belt Drive — Horizontal
ESP (“ H2O)
Turns Open
0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.1 --- --- --- --- --- --- --- --- --- --- 1726 0.37
0.2 --- --- --- --- --- --- --- --- 1720 0.43 1575 0.36
0.3 --- --- --- --- 1888 0.57 1744 0.48 1562 0.41 1398 0.34
0.4 --- --- --- --- 1740 0.54 1579 0.45 1398 0.38 1217 0.31
0.5 --- --- 1797 0.56 1586 0.51 1420 0.42 1216 0.36 1004 0.28
0.6 1849 0.62 1658 0.53 1429 0.48 1252 0.40 997 0.32 --- ---
0.7 1731 0.59 1528 0.51 1266 0.45 1039 0.36 --- --- --- ---
0.8 1572 0.55 1355 0.47 1068 0.41 --- --- --- --- --- ---
0.9 1431 0.52 1171 0.43 --- --- --- --- --- --- --- ---
1.0 1245 0.48 987 0.39 --- --- --- --- --- --- --- ---
1.1 1059 0.44 --- --- --- --- --- --- --- ---
High-Static Belt Drive — Horizontal
ESP (“ H2O)
Turns Open
0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.6 --- --- --- --- --- --- --- --- --- --- 1669 0.53
0.7 --- --- --- --- --- --- --- --- 1741 0.61 1553 0.51
0.8 --- --- --- --- --- --- 1792 0.66 1610 0.57 1408 0.48
0.9 --- --- --- --- --- --- 1680 0.63 1479 0.53 1264 0.44
1.0 --- --- --- --- 1765 0.71 1568 0.59 1323 0.50 1093 0.41
1.1 --- --- --- --- 1640 0.67 1422 0.55 1168 0.46 --- ---
1.2 --- --- 1784 0.78 1515 0.64 1259 0.51 995 0.43 --- ---
1.3 1821 0.89 1621 0.73 1360 0.59 1091 0.47 --- --- --- ---
1.4 1694 0.84 1458 0.68 1202 0.55 --- --- --- --- --- ---
1.5 1567 0.80 1324 0.63 1042 0.51 --- --- --- --- --- ---
1.6 1417 0.75 1148 0.59 --- --- --- --- --- --- --- ---
1.7 1262 0.70 --- --- --- --- --- --- --- --- --- ---
1.8 1120 0.66 --- --- --- --- --- --- --- --- --- ---
Note: Tables represent dry coil without filter; to compensate for filter, add 0.08” to measured E.S.P. SCFM correction for wet coil = 4%.
24 www.daikinac.com SS-DSG3
Airflow Data — 5 Tons
Standard Direct-Drive — Horizontal Standard Direct-Drive — Down Shot
CFM Static Amps Watts RPM Speed Tap CFM Static Amps Watts RPM Speed
Tap
1215 0.1 1.4 165 610
T1
1205 0.1 1.47 180 635
T1
1150 0.2 1.46 175 645 1150 0.2 1.54 185 675
1085 0.3 1.54 180 690 1065 0.3 1.59 185 730
1010 0.4 1.64 195 725 980 0.4 1.68 195 760
900 0.5 1.74 205 780 860 0.5 1.79 200 810
840 0.6 1.77 215 810 800 0.6 1.82 220 840
1395 0.1 1.86 230 670
T2
1375 0.1 1.94 235 690
T2
1325 0.2 1.95 240 705 1300 0.2 2.01 245 720
1260 0.3 2.01 250 735 1230 0.3 2.05 255 750
1210 0.4 2.10 260 770 1180 0.4 2.15 265 790
1135 0.5 2.16 265 810 1100 0.5 2.22 275 830
1040 0.6 2.28 280 860 1005 0.6 2.33 285 890
970 0.7 2.38 290 885 970 0.7 2.43 295 900
910 0.8 2.46 300 925 915 0.8 2.51 310 940
840 0.9 2.52 310 955 845 0.9 2.57 315 980
1790 0.1 3.24 425 810
T3
1755 0.1 3.34 385 850
T3
1735 0.2 3.37 435 830 1700 0.2 3.47 395 865
1670 0.3 3.45 450 865 1665 0.3 3.56 410 895
1610 0.4 3.55 465 890 1580 0.4 3.68 425 930
1560 0.5 3.60 475 920 1545 0.5 3.72 435 955
1520 0.6 3.70 490 945 1505 0.6 3.80 520 990
1470 0.7 3.80 500 970 1430 0.7 3.93 530 1020
1410 0.8 3.94 510 995 1370 0.8 4.08 535 1040
1345 0.9 3.98 530 1035 1300 0.9 4.12 570 1070
2005 0.1 4.30 575 880
T4
1945 0.1 4.46 600 920
T4
1965 0.2 4.41 590 900 1910 0.2 4.57 620 940
1895 0.3 4.52 610 930 1850 0.3 4.66 635 965
1835 0.4 4.63 620 955 1795 0.4 4.78 655 990
1790 0.5 4.75 635 980 1760 0.5 4.84 670 1020
1745 0.6 4.84 650 1005 1710 0.6 4.96 685 1045
1695 0.7 4.91 660 1030 1640 0.7 5.06 675 1065
1650 0.8 5.03 675 1055 1610 0.8 5.19 690 1090
1600 0.9 5.10 675 1080 1560 0.9 5.22 700 1125
2120 0.1 5.10 690 930
T5
2090 0.1 5.35 720 970
T5
2075 0.2 5.15 710 950 2040 0.2 5.38 740 990
2025 0.3 5.23 720 975 1985 0.3 5.70 755 1025
1975 0.4 5.35 735 995 1935 0.4 5.44 760 1035
1930 0.5 5.46 750 1020 1900 0.5 5.82 780 1050
1875 0.6 5.59 770 1040 1855 0.6 5.73 800 1075
1835 0.7 5.64 780 1065 1810 0.7 5.69 810 1090
1795 0.8 5.73 790 1090 1750 0.8 5.82 825 1120
1735 0.9 5.82 805 1110 1680 0.9 5.94 840 1145
Notes• Assumes dry coil with filter in place; SCFM correction for wet coil = 4%
• Five-ton models are shipped from the factory with speed tap set on T4.
SS-DSG3 www.daikinac.com 25
Airflow Data — 5 Tons (cont.)
Standard Belt Drive — Down Shot
ESP (“ H2O)
Turns Open
0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.1 --- --- --- --- 2071 0.62 1972 0.54 1816 0.41 1668 0.34
0.2 --- --- 2180 0.70 1977 0.59 1846 0.51 1699 0.39 1533 0.33
0.3 2110 0.79 2066 0.66 1873 0.56 1721 0.47 1572 0.35 1387 0.30
0.4 2024 0.76 1950 0.63 1769 0.53 1596 0.44 1443 0.33 1247 0.27
0.5 1937 0.73 1833 0.60 1643 0.50 1554 0.41 1302 0.30 --- ---
0.6 1851 0.69 1716 0.56 1523 0.46 1330 0.38 --- --- --- ---
0.7 1764 0.65 1601 0.53 1393 0.42 1186 0.34 --- --- --- ---
0.8 1653 0.61 1477 0.49 1256 0.39 --- --- --- --- --- ---
0.9 1534 0.57 1350 0.45 --- --- --- --- --- --- --- ---
1.0 1411 0.53 1180 0.40 --- --- --- --- --- --- --- ---
1.1 1270 0.49 --- --- --- --- --- --- --- --- --- ---
High-Static Belt Drive — Down Shot
ESP (“ H2O)
Turns Open
0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.6 --- --- --- --- --- --- 2227 0.86 2050 0.73
0.7 --- --- --- --- --- --- 2102 0.82 1932 0.69
0.8 --- --- --- --- --- --- 2274 0.93 1999 0.79 1820 0.67
0.9 --- --- --- --- 2304 1.03 2130 0.88 1859 0.76 1630 0.63
1.0 --- --- --- --- 2162 0.98 2010 0.86 1694 0.72 1487 0.59
1.1 --- --- 2325 1.15 2027 0.94 1820 0.79 1543 0.68 1267 0.55
1.2 2355 1.26 2247 1.11 1902 0.90 1721 0.77 1331 0.63 --- ---
1.3 2247 1.22 2062 1.05 1768 0.87 1557 0.71 --- --- --- ---
1.4 2151 1.19 1932 1.01 1579 0.82 1374 0.66 --- --- --- ---
1.5 2004 1.14 1768 0.95 1339 0.74 --- --- --- --- --- ---
1.6 1895 1.10 1637 0.91 --- --- --- --- --- --- --- ---
1.7 1727 1.04 1331 0.80 --- --- --- --- --- --- --- ---
1.8 1391 0.92 --- --- --- --- --- --- --- --- --- ---
Note: Tables represent dry coil without filter; to compensate for filter, add 0.08” to measured E.S.P. SCFM correction for wet coil = 4%.
26 www.daikinac.com SS-DSG3
Airflow Data — 5 Tons (cont.)
Air Flow Pressure Drop of Down Flow Economizer
Airflow Pressure Drop of Downflow Economizer for 3 to 6 Ton Rofftop Units (100% Return Air)
SCF, 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800
in WG 0.02 0.04 0.05 0.07 0.09 0.12 0.14 0.17 0.21 0.24 0.28
Standard Belt Drive — Horizontal
ESP (“ H2O)
Turns Open
0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.1 --- --- --- --- --- --- 2105 0.49 1940 0.40
0.2 --- --- --- --- --- --- 2147 0.57 1975 0.47 1782 0.39
0.3 --- --- --- --- 2178 0.63 2001 0.53 1828 0.43 1613 0.36
0.4 --- --- --- --- 2057 0.60 1855 0.50 1678 0.41 1450 0.33
0.5 --- --- 2131 0.68 1910 0.57 1691 0.47 1515 0.38 1252 0.29
0.6 2152 0.78 1995 0.64 1771 0.53 1546 0.44 1320 0.34 --- ---
0.7 2051 0.74 1862 0.61 1620 0.49 1379 0.40 --- --- --- ---
0.8 1922 0.70 1718 0.57 1461 0.46 1202 0.37 --- --- --- ---
0.9 1784 0.66 1570 0.53 1296 0.43 --- --- --- --- --- ---
1.0 1641 0.62 1371 0.48 --- --- --- --- --- --- --- ---
1.1 1477 0.58 1200 0.44 --- --- --- --- --- --- --- ---
1.2 1292 0.53 --- --- --- --- --- --- --- --- --- ---
High-Static Belt Drive — Horizontal
ESP (“ H2O)
Turns Open
0 1 2 3 4 5
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
0.6 --- --- --- --- --- --- 2164 0.89 1985 0.76
0.7 --- --- --- --- --- --- 2232 0.99 2047 0.85 1858 0.72
0.8 --- --- --- --- --- --- 2104 0.95 1943 0.82 1735 0.70
0.9 --- --- --- --- 2200 1.09 1995 0.92 1819 0.79 1603 0.67
1.0 --- --- 2297 1.22 2086 1.06 1900 0.89 1687 0.75 1410 0.62
1.1 --- --- 2204 1.19 1995 1.02 1774 0.86 1543 0.71 --- ---
1.2 2249 1.32 2101 1.15 1875 0.99 1624 0.81 1352 0.66 --- ---
1.3 2175 1.28 1958 1.11 1740 0.94 1482 0.77 --- --- --- ---
1.4 2072 1.25 1836 1.06 1587 0.89 1308 0.72 --- --- --- ---
1.5 1945 1.20 1685 1.00 1402 0.83 --- --- --- --- --- ---
1.6 1841 1.15 1519 0.94 --- --- --- --- --- --- --- ---
1.7 1684 1.09 --- --- --- --- --- --- --- --- --- ---
1.8 1541 1.03 --- --- --- --- --- --- --- --- --- ---
SS-DSG3 www.daikinac.com 27
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0 700600500400300200100
Air Velocity (FPM)
Resi
stan
ce (i
n. w
.g.)
2" Deep
Flanders Pre Pleat M13Air Velocity vs Resistance
(Test Size: 24" x 24" x 2" High Capacity)
High Efficiency MERV 13 Air Filter Option
Crankcase Heater, High Efficiency MERV 13 Air Filter Option
Crankcase Heater Selection TableZP/ZPS… Compressor Diameter Compressor Voltage Crankcase
Heater Watts230V 460V 575V16-31 5.5" 0163R00002S 0163R00031S 0163R00032S 40
39-83 6.58/7.3" 0130L00017S 0130L00018S 0130L00019S 70
103-137 9.14” 0130L00020S 0130L00021S 0130L00022S 90
DC*,DT* & DS* Tonnage Compressor Voltage Crankcase Heater Watts230V 460V 575V
3 Ton 0163R00002S 0163R00031S 0163R00032S 40
4 Ton-5 Ton 0130L00017S 0130L00018S 0130L00019S 70
*Includes C,G&H models.
Tonnage: Filter Nominal Size: Part Number: Order QTY:
3 24 x 24 x 2 0160L00203 1
4 14 x 20 x 2 0160L00204 4
5 16 x 20 x 2 0160L00205 4
28 www.daikinac.com SS-DSG3
Electrical Data
4 Tons
5 Tons
Model Number Electrical Rating
Compressor Circuit 1 Compressor Circuit 2 Outdoor Fan Motor Indoor Fan Motor Optional Powered Convienience Outlet Power Supply
RLA LRA RLA LRA QTY HP FLA Type HP FLA FLA MCA MOP
DSG036XXX1D 208/230-1-60 16.7 79.0 1 0.25 1.40Standard -
Direct Drive0.33 2.46
- 24.7 / 24.7 40 / 407.2 / 6.5 31.9 / 31.2 45 / 45
DSG036XXX3B 208/230-3-60 10.4 73.0 1 0.25 1.40Standard -
Direct Drive1.50 3.40
- 16.9 / 16.9 25 / 257.2 / 6.5 24.1 / 23.4 30 / 30
DSG036XXX3D 208/230-3-60 10.4 73.0 1 0.25 1.40Standard - Belt Drive
0.33 2.46- 17.9 / 17.9 25 / 25
7.2 / 6.5 25.1 / 24.4 35 / 30
DSG036XXX3H 208/230-3-60 10.4 73.0 1 0.25 1.40High Static - Belt Drive
1.50 4.60- 19.1 / 19.1 25 / 25
7.2 / 6.5 26.3 / 25.6 35 / 35
DSG036XXX4B 460-3-60 5.8 38.0 1 0.25 0.70Standard - Belt Drive
1.00 1.70- 9.6 15
3.3 12.9 15
DSG036XXX4H 460-3-60 5.8 38.0 1 0.25 0.70High Static - Belt Drive
1.50 2.10- 10.0 15
3.3 13.3 15
DSG036XXX7B 575-3-60 3.8 36.5 1 0.25 0.55Standard - Belt Drive
1.50 2.30- 7.6 15
2.6 10.2 15
Model Number Electrical Rating
Compressor Circuit 1 Compressor Circuit 2 Outdoor Fan Motor Indoor Fan Motor Optional Powered Convienience Outlet Power Supply
RLA LRA RLA LRA QTY HP FLA Type HP FLA FLA MCA MOP
DSG048XXX1D 208/230-1-60 19.9 109.0 1 0.25 1.40Standard -
Direct Drive0.75 2.80
- 29.0 / 29.0 45 / 457.2 / 6.5 36.2 / 35.5 50 / 50
DSG048XXX3D 208/230-3-60 13.1 83.0 1 0.25 1.40Standard -
Direct Drive0.75 2.80
- 20.6 / 20.6 30 / 307.2 / 6.5 27.8 / 27.1 40 / 40
DSG048XXX3B 208/230-3-60 13.1 83.1 1 0.25 1.40Standard - Belt Drive
1.00 3.40- 21.2 / 21.2 30 / 30
7.2 / 6.5 28.4 / 27.7 40 / 40
DSG048XXX3H 208/230-3-60 13.1 83.1 1 0.25 1.40High Static - Belt Drive
1.50 4.60- 22.4 / 22.4 35 / 35
7.2 / 6.5 29.6 / 28.9 40 / 40
DSG048XXX4B 460-3-60 6.1 41.0 1 0.25 0.70Standard - Belt Drive
1.00 1.70- 10.0 15
3.3 13.3 15
DSG048XXX4H 460-3-60 6.1 41.0 1 0.25 0.70High Static - Belt Drive
1.50 2.10- 10.4 15
3.3 13.7 15
DSG048XXX7B 575-3-60 4.4 33.0 1 0.25 0.55Standard - Belt Drive
1.50 2.30- 8.3 15
2.6 10.9 15
Model Number Electrical Rating
Compressor Circuit 1 Compressor Circuit 2 Outdoor Fan Motor Indoor Fan Motor Optional Powered Convienience Outlet Power Supply
RLA LRA RLA LRA QTY HP FLA Type HP FLA FLA MCA MOP
DSG060XXX1D 208/230-1-60 26.4 134.0 1 0.25 1.40Standard -
Direct Drive1.00 6.90
- 41.3 / 41.3 60 / 607.2 / 6.5 48.5 / 47.8 70 / 70
DSG060XXX3D 208/230-3-60 16.0 110.0 1 0.25 1.40Standard -
Direct Drive1.00 6.90
- 28.3 / 28.3 40 / 407.2 / 6.5 35.5 / 34.8 50 / 50
DSG060XXX3B 208/230-3-60 16.0 110.0 1 0.25 1.40Standard - Belt Drive
1.00 3.20- 24.6 / 24.6 40 / 40
7.2 / 6.5 31.8 / 31.1 45 / 45
DSG060XXX3H 208/230-3-60 16.0 110.0 1 0.25 1.40High Static - Belt Drive
1.50 4.80- 26.2 / 26.2 40 / 40
7.2 / 6.5 33.4 / 32.7 45 / 45
DSG060XXX4B 460-3-60 7.8 52.0 1 0.25 0.70Standard - Belt Drive
1.00 1.50- 11.9 15
3.3 15.2 20
DSG060XXX4H 460-3-60 7.8 52.0 1 0.25 0.70High Static - Belt Drive
1.50 2.40- 12.8 20
3.3 16.1 20
DSG060XXX7B 575-3-60 5.7 38.9 1 0.25 0.55Standard - Belt Drive
1.00 1.20- 8.9 15
2.6 11.5 15
3 Tons
SS-DSG3 www.daikinac.com 29
Dimensions
11.2
65
33.8
05
73.9
4548
.196
6.19
610
.060
12.0
00
7.16
517
.000
31.5
4011
.000
20.8
53
4.47
5
ALL
DIM
EN
SIO
NS
GIV
EN
AR
E IN
INC
HE
SA
LL D
IME
NS
ION
S A
ND
SP
EC
IFIC
AT
ION
S A
RE
SU
BJE
CT
TO
CH
AN
GE
WIT
HO
UT
NO
TIC
E
DS
G03
6-06
03
TH
RU
5 T
ON
CO
MM
ER
CIA
L
GA
S L
INE
EN
TR
AN
CE
CO
MB
US
TIO
N A
IR IN
LET
(G
AS
UN
ITS
)
FLU
E/V
EN
T O
UT
LET
FR
ON
T V
IEW
TO
P V
IEW
FO
RK
HO
LES
BO
TH
SID
ES
A
ND
BO
TH
EN
DS
CO
ND
EN
SA
TE
DR
AIN
OU
TLE
T
LIF
TIN
G S
HA
CK
LE
HO
LES
BO
TH
SID
ES
A
ND
EN
DS
SU
PP
LY A
IR D
UC
T
RE
TU
RN
AIR
DU
CT
RIG
HT
EN
D V
IEW
30 www.daikinac.com SS-DSG3
Dimensions (cont.)
7.984
"C"
"B"
10.372
5.872
8.55511.000
17.000
6.192
23.442
48.312
20.905
5.104 12.000
19.470
5.558 25.000
74.061
"A"
LINE WIRE ENTRANCE
TSTAT WIRE ENTRANCE
LEFT END VIEW
SUPPLY AIR DUCT
CONDENSATEDRAINBOTTOM EXIT
RETURN AIR DUCT
BASE PAN VIEW(VIEWED FROM TOP)
MODEL TONNAGES "A" "B" "C"3 TON COMMERCIAL
GAS, HT PUMP, AIR CONDITIONER 38.840 16.555 26.055
4 TON COMMERCIALGAS, HT PUMP, AIR CONDITIONER 38.840 16.555 26.055
5 TON COMMERCIALGAS, HT PUMP, AIR CONDITIONER 38.840 16.555 26.055
6 TON COMMERCIALGAS, HT PUMP, AIR CONDITIONER 42.840 20.555 30.055
7.984
"C"
"B"
10.372
5.872
8.55511.000
17.000
6.192
23.442
48.312
20.905
5.104 12.000
19.470
5.558 25.000
74.061
"A"
LINE WIRE ENTRANCE
TSTAT WIRE ENTRANCE
LEFT END VIEW
SUPPLY AIR DUCT
CONDENSATEDRAINBOTTOM EXIT
RETURN AIR DUCT
BASE PAN VIEW(VIEWED FROM TOP)
MODEL TONNAGES "A" "B" "C"
3 TON COMMERCIALGAS, HT PUMP, AIR CONDITIONER 38.840 16.555 26.055
4 TON COMMERCIALGAS, HT PUMP, AIR CONDITIONER 38.840 16.555 26.055
5 TON COMMERCIALGAS, AIR CONDITIONER 38.840 16.555 26.055
5 TON COMMERCIALHT PUMP 42.840 20.555 30.055
SS-DSG3 www.daikinac.com 31
Unit Clearances
Electrical Entrance Locations
30¼”
12⅜”
Low-Voltage Entrance
(Remove Plug)High-Voltage Entrance
3½” Dia.
47½”7½”
Power Thru the Curb
Low-Voltage Entrance
Corner & Center-of-Gravity Locations
30”
Compressor
Return
Evaporator Coil
Supply
CondenserCoil
37”
Unit Weights
3-Ton Weights
4-Ton Weights
5-Ton Weights
Corner Weight (A) 109 113 113
Corner Weight (B) 178 192 194
Corner Weight (C) 109 118 119
Corner Weight (D) 179 192 194
Unit Shipping Weight 600 615 620
Unit Operating Weight 575 640 645
Note: Weights are calculated without accessories installed.
Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a clearance of 48" on all sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit Beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit’s fresh-air intake.
48"
48"
48"
48"
32 www.daikinac.com SS-DSG3
Roof Curb Installation — Rigging
Provisions for forks have been included in the unit base frame. No other fork locations are approved.
• Unit must be lifted by the four lifting holes located at the base frame corners.
• Lifting cables should be attached to the unit with shackles.
• The distance between the crane hook and the top of the unit must not be less than 60”.
• Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are in-tended to protect unit base frame from fork lift damage. To remove the struts, ex-tract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit.
Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof Curb Installation Instructions Manual.
Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual.
Lower unit carefully onto roof mounting curb. While rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end.
Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is used, take care to center the unit. Check for proper alignment and orientation of supply and return openings with duct.
To assist in determining rigging requirements, unit weights are shown below.
Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association.Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. Check for adequate fastening method prior to setting the unit on the curb.Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package.• Determine sufficient structural support before locating and mounting the curb and package unit.• Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before mounting
the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. Cantilevered-type curbs are not available from the factory.
• Contractor furnishes curb insulation, cant strips, flashing, and general roofing material.• Support curbs on parallel sides with roof members. To prevent damage to the unit, the roof members cannot penetrate supply
and return duct openings.Note: The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not recommended.See the manual shipped with the roof curb for assembly and installation instructions.
3-D View
14 x 20Supply Opening
31⅝ x 14Return Opening
70¾ 40¼
14
15⁄6
¾
14
1⅜
Insulated Panels
Top View
SS-DSG3 www.daikinac.com 33
Wiring Diagram — DSG0360901D/DSG048(090/115)1D* SINGLE PHASE 208/230V/60HZ DIRECT DRIVE
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
GND
YL
208-240/1/60SEE NOTE 5
RD
YL RD
BR
EA
K FO
R TW
O S
TAG
E
T2
CO
MP
RE
SS
OR
IIC
C RD
YL
L2C
T2
L1
T1
RD
BK
BK
PU
RD
C22
OR
SP
EE
D-U
P
MO
UN
T
T1P2
RE
QU
IRE
DS
CR
EW
P3135120
150
FUSE 3 AMP MAX
F1
WH
YL
RD
RD
118129
7 1042 5
631
FS
RD
BK
SEE NOTE 8GREEN JUMPER
CO
OL
DI
L1H
EA
TU
NU
SE
DL2
BL
BK
YLYL
PU
BRBL
RD
YL
WH
GRBL
P1
EC
ON
RD
ALS
PS
RSPLF
YL
YL
NOTE 4
GAS VALVE
MV
PU
W. R.GAS VALVE
PU
(ALT.) HONEYWELL
BL
BR
PU
PU
PU
BK
R GY1 W1
OR
RD
TO THERMOSTAT
CMV
FS
IGN
VM
BL
RD
BL
BK
GVGV
TB1
YL
BL
YL
GR
Y2
PU
31
RD
RDLS
208TR
BL
24V
C
PK
240
BL
NOTE 2
RD
PU
BK
RD
RD
BL
PK
TB1 S2
BL/PK
HPS
LPS
BL
GR
BK
BR
RD
PU
EM
BL
3SPEED
PU
PU
BR
CM
BK
ALTERNATEMOTOR6-WIRESSEE NOTE 6 & 7
BC
BC3SPEED
BL
EM
RD
BK
BR
RD
PU
COMP
T1T2T3
SEE NOTE 7
RD
RD
BK
YL
SEENOTE 9
F H
W2
BR
YL
BL
WH
YL/PK
RCCF
BL
5 8
41
9
7
623
GR
GR
S2S1
RD
RD
YL
BR
BR
FOR SMOKE/FIREDETECTOR JUMPER
BK
++
2
0140
L028
98-B
34 www.daikinac.com SS-DSG3
Wiring Diagram – DSG0360901D/DSG048(090/115)1D* SINGLE PHASE 208/230V/60HZ DIRECT DRIVE
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).
AUXILLARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
LS4
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
STATUS LIGHT
3 BLINKS
6 BLINKS
2 BLINKS
4 BLINKS
5 BLINKS
OFF
ON
1 BLINK
FALSE FLAME SENSED
OUTPUT DELAY
OPEN LIMIT SWITCH
COMPRESSOR
WITHOUT INDUCER ONPRESSURE SWITCH CLOSED
PRESSURE SWITCHOPEN
IGNITION FAILUREOR
OPEN ROLLOUT SWITCHOR
OPEN AUX. LIMIT SWITCH
NORMAL OPERATION
NO POWER ORINTERNAL CONTROL
EQUIP. STATUS
TO THERMOSTATTERMINAL BLOCK
GR
5
79ECON
IIC
Y1W Y2
3
6
1210
8
11
RSALS
PS
BAD SWITCHAUX. LIMIT OPEN
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVEBAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
PRESSURE SWITCHCHECK
CHECK
GAS PRESSURE
FLAME ROLLOUTFLAME SENSOR
GAS VALVE
CHECK INPUT POWER
REPLACE CONTROLGAS FLOW
CHECK
-
C
GV
C
CM CONDENSER MOTOR
LS LIMIT SWITCH
VENT MOTOR RELAYVENT MOTOR
PRESSURE SWITCH
TERMINAL BLOCK (24V SIGNAL)ROLLOUT SWITCH
VMRVM
PS
PLF
TB1RS
NOTES
CONTACTOR
GAS VALVE
IGNITOR
EQUIPMENT GROUNDFLAME SENSOR
EVAPORATOR MOTORFUSEF
C
GV
FSGND
IGNIIC
EM
COMPRESSOR
COMPONENT LEGEND
COMPALS
TR TRANSFORMER
208-240/1/60 0140L02898-B
HPSLPS
HPS HIGH PRESSURE SWITCH HIGH VOLTAGE
FACTORY WIRING
OPTIONAL HIGH VOLTAGE
LOW VOLTAGE
FIELD WIRING
LINE VOLTAGE
LOW VOLTAGE
BL
RD
Y1
YL
W
BL
G
R
W
NO ECONOMIZER
G
YL
RD
Y1
PK
WH
W
R RD
WH
GR
C
R
YL
GR
Y1
G
WH
WITH ECONOMIZER OPTION
C
GR
THERMOSTATFIELD WIRING
BL
C
2 STAGE COOLING
TB1
G
R
W
Y
C
TB1
TB1
Y
W
R
G
C
W
Y2
G
R
C
Y1
STAT
STAT
STAT
BL/PK BLUE WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOWIIC
FS
TR
FSF
IGN
2 13
3. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING SPEED AT COOL TERMINAL. CHANGE HEATING SPEED AT HEAT TERMINAL ON CONTROL BOARD
4. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY.
++ USE NEC CLASS 2 WIRE.5. USE COPPER CONDUCTORS ONLY.
7. SPEED TAP TERMINATIONS SHOWN ON DIAGRAM ARE REPRESENTATIVE, BUT ACTUAL FACTORY SETTING MAY BE DIFFERENT BASED ON HEATING VALUE AND CAPACITY OF UNIT.
6. PURPLE WIRE CONNECTS TO TRANSFORMER (PIN 1).
9. FOR LOW STAGE OPERATION ONLY, REMOVE WHITE JUMPER. FOR 2 STAGE OPERATION, REMOVE JUMPER AND CONNECT W2 TO W1 ON THERMOSTAT.
SEE UNIT RATING PLATE FOR TYPE AND SIZEOF OVERCURRENT PROTECTION.
BLOWER CAPACITORBC
L2
L2T2
SUPPLY VOLTAGE208-240/1/60
L1
L1C T1
EM
CR
SCOMP
H CRCCF
CMF
C
VMLISEE NOTE 2
PCB
HEAT
COOL
FCPCB
DI
8. TO RUN DIFFERENT SPEED FOR HEATING AND COOLING, DISCONNECT GEEEN JUMPER FROM "COOL" TERMINAL AND REPLACE WITH APPROPRIATE SPEED TAP. THEN PLACE DISCONNECTED END OF JUMPER ON "UNUSED" TERMINAL LEFT OPEN BY MOVING THE SPEED TAP.
RUN CAPACITOR FOR CONDENSER FANRCCF
LPS LOW PRESSURE SWITCH
BK - HIGH SPEEDBL - MED. SPEED
RD - LOW SPEED3 SPEED MOTOR
32
6
7
9
1 485
S2S1
SEENOTE 5
Y2
Y2
Y2
EQUIPMENTGROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITERSWITCH (PRESS.)
OVERCURRENTPROT. DEVICE
JUNCTION
TERMINAL
INTERNAL TOINTEGRATED
CONTROL
PLUGCONNECTION
++
++
OPTIONAL LOW VOLTAGE
CHECK FUSE ON CONTROL
SS-DSG3 www.daikinac.com 35
Wiring Diagram — DSG0360451D* SINGLE PHASE 208/230V/60HZ DIRECT DRIVE
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
GND
YL
208-240/1/60SEE NOTE 5
RD
YL RD
BR
EA
K FO
R TW
O S
TAG
E
T2
CO
MP
RE
SS
ORIIC
C RD
YL
L2C
T2
L1
T1
RD
BK
BK
PU
RD
C22
OR
SP
EE
D-U
P
MO
UN
T T1P2
RE
QU
IRE
DS
CR
EW
P3135120
150
FUSE 3 AMP MAX
F1
WH
YL
RD
RD
118129
7 1042 5
631
FS
RD
BK
CO
OL
DI
L1H
EA
TU
NU
SE
DL2
BL
BK
YLYL
PU
BR
BL
RD
YL
WH
GRBL
P1
EC
ON
RDALS
GR
PS
RSPLF
YL
YL
NOTE 4
GAS VALVE
MV
BL
W. R.GAS VALVE
PU
(ALT.) HONEYWELL
BR
PU
PU
PU
BK
BR
R GY1W1
OR
RD
TO THERMOSTAT
CMV
FS
IGN
VM
BL
RD
BL
BK
GVGV
TB1
BL
YL
GR
S2
R
31
RD
RDLS
208TR
BL
24V
C
PK
240
BL
NOTE 2
RD
PU
BK
RD
RD
BL
BL/PK
YL/PK
HPS
LPS
BL
GR
BK
BR
RD
PU
EM
BL
3 SPEED
PU
PUBR
CM
BK
ALTERNATEMOTOR6-WIRESSEE NOTE 6 & 7
BC
BC3 SPEED
BL
EM
RD
BK
BR
RD
PU
COMP
T13T 2T
SEE NOTE 7
RD
RD
BK
YL
F H
YL
BL
RCCF
BL
BK
5 8
41
9
7
623
R
YLYL
PU
Y2
PU
S1
BR
GR
PK
FOR SMOKE/FIREDETECTOR JUMPER
SEE NOTE 8GREEN JUMPER
2
0140
L029
00-B
36 www.daikinac.com SS-DSG3
Wiring Diagram — DSG0360451D* SINGLE PHASE 208/230V/60HZ DIRECT DRIVE
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).
AUXILLARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
LS4
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
STATUS LIGHT
3 BLINKS
6 BLINKS
2 BLINKS
4 BLINKS
5 BLINKS
OFF
ON
1 BLINK
OPEN AUX. LIMIT
FALSE FLAME SENSED
OUTPUT DELAY
OPEN LIMIT SWITCH
COMPRESSOR
WITHOUT INDUCER ON
PRESSURE SWITCHSWITCH
OPEN
OPEN ROLLOUTSWITCH
IGNITION FAILURE
NORMAL OPERATIONNO POWER OR
INTERNAL CONTROL
EQUIP. STATUS
OR
OR
FAULT
TO THERMOSTATTERMINAL BLOCK
GR
5
79
ECON
IIC
Y1W Y2
3
6
1210
8
11
RSALS
PS
BAD SWITCHAUX. LIMIT OPEN
ANTI-CYCLE TIMER
MAIN LIMIT OPENBAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
PRESSURE SWITCHCHECK
CHECK
GAS PRESSURE
FLAME ROLLOUTFLAME SENSOR
GAS VALVE
CHECK INPUT POWER
REPLACE CONTROLGAS FLOW
CHECK
-
C
GV
C
CM CONDENSER MOTOR
LS LIMIT SWITCH
VENT MOTORRELAYVENT MOTOR
PRESSURE SWITCH
TERMINAL BLOCK (24V SIGNAL)ROLLOUT SWITCH
VMRVM
PSPLF
TB1RS
NOTES
CONTACTOR
GAS VALVE
IGNITOR
EQUIPMENT GROUNDFLAME SENSOR
EVAPORATOR MOTORFUSEF
C
GV
FSGND
IGNIIC
EM
COMPRESSOR
COMPONENT LEGEND
COMPALS
TB1
TR TRANSFORMER
208-240/1/60 0140L02900-B
HPSLPS
HPS HIGH PRESSURE SWITCH HIGH VOLTAGE
FACTORY WIRING
OPTIONAL HIGH VOLTAGE
LOW VOLTAGE
FIELD WIRING
LINE VOLTAGE
LOW VOLTAGE
BL
RD
Y1
YL
W
BL
G
R
W
NO ECONOMIZER
G
YL
RD
Y2
Y1
PK
WH
W
R RD
WH
GR
C
R
YL
GR
Y1
G
WH
WITH ECONOMIZER OPTION
C
GR
THERMOSTATFIELD WIRING
BL
C
2 STAGE COOLING
TB1
G
R
W
Y
C
TB1
TB1
Y
W
R
G
C
W
Y2
G
R
C
Y1
STAT
STAT
STAT
BL/PK BLUE WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOWTB1
IICFS
TR
FSF
IGN
2 13
3. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING SPEED AT COOL TERMINAL. CHANGE HEATING SPEED AT HEAT TERMINAL ON CONTROL BOARD
4. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY.
++ USE NEC CLASS 2 WIRE.
5. USE COPPER CONDUCTORS ONLY.
7. SPEED TAP TERMINATIONS SHOWN ON DIAGRAM ARE REPRESENTATIVE, BUT ACTUAL FACTORY SETTING MAY BE DIFFERENT BASED ON HEATING VALUE AND CAPACITY OF UNIT.
6. PURPLE WIRE CONNECTS TO TRANSFORMER (PIN 1).
SEE UNIT RATING PLATE FOR TYPE AND SIZEOF OVERCURRENT PROTECTION.
BLOWER CAPACITORBC
L2
L2T2
SUPPLY VOLTAGE208-240/1/60
L1
L1C T1
EM
CR
SCOMP
H CRCCF
CMF
C
VMLISEE NOTE 2
PCB
HEAT
COOL
FCPCB
DI
8. TO RUN DIFFERENT SPEED FOR HEATING AND COOLING, DISCONNECT GEEEN JUMPER FROM "COOL" TERMINAL AND REPLACE WITH APPROPRIATE SPEED TAP. THEN PLACE DISCONNECTED END OF JUMPER ON "UNUSED" TERMINAL LEFT OPEN BY MOVING THE SPEED TAP.
RUN CAPACITOR FOR CONDENSER FANRCCF
LPS LOW PRESSURE SWITCH
BK - HIGH SPEEDBL - MED. SPEEDRD - LOW SPEED3 SPEED MOTOR
5 8
41
9
7
623
S2S1
SEENOTE 4
PLF
Y2
Y2
EQUIPMENTGROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITERSWITCH (PRESS.)
OVERCURRENTPROT. DEVICE
JUNCTION
TERMINAL
INTERNAL TOINTEGRATED
CONTROL
PLUGCONNECTION
++
OPTIONAL LOW VOLTAGE
STICKING GAS VALVE
PRESSURE SWITCH CLOSED
CHECK FUSE ON CONTROL
SS-DSG3 www.daikinac.com 37
Wiring Diagram — DSG060*1D SINGLE PHASE 208/230V/60HZ DIRECT DRIVE
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
POWER SUPPLY240/1/60
BL
BR
EA
K FO
R TW
O S
TAG
E
T2
CO
MP
RE
SS
OR
RCCF
L2C
T2
L1
T1
NOTE 2
S R C
COMP
CM
VMR
C
24V
TR
C22
SP
EE
D-U
P
MO
UN
T
T1
P2
RE
QU
IRED
SC
RE
W
P3135
120
150
FUSE 3 AMP MAX
F1
LS
118
1297 104
2 563
1
FS
NOTE 6SEE
CO
OL
DI
L1H
EA
TU
NU
SE
DL2P
1
EC
ON
ALS
PS
RS
GAS VALVE
MV
2
1 4
5
W. R.GAS VALVE
(ALT.) HONEYWELL
3 6
1 2 3
MV
FS
IGN
VM
GVGV
TB1
LPS
HPS
1 5
EM
Y2Y1
GNDYL
RD
YL
WH
BR
EA
K FO
R TW
O S
TAG
E
T2
CO
MP
RE
SS
OR
RD
RCCF
RD
YL
RD
BK
BKRD
BL
BK
BK
PU
RD
S R C
COMP
BK
PU
CM
BR
PK
240
PKVMR
BL
C
24V
TR
BL
208
C22
OR
SP
EE
D-U
P
MO
UN
T
T1
P2
RE
QU
IRED
SC
RE
W
P3135
120
150
FUSE 3 AMP MAX
F1
LSRD
RD
WH
GR
YL
RD
RD
118
1297 104
2 563
1
FS
RD
BR
NOTE 6SEE
CO
OL
DI
L1H
EA
TU
NU
SE
DL2
BL
WH
YLYL
PU
RDBL
BL
BLBL
EC
ON
RD
GR
ALS
GR
PS
RSPLF
YL
YL
NOTE 4
GAS VALVE
MV
2
1 4
5
YL
BL
W. R.GAS VALVE
PU
(ALT.) HONEYWELL
3 6
YLBR WH
BL YL
PU
PU
PU
1 2 3
BR
OR
RD
MV
FS
IGN
VM
BL
BL
YLWH
BR
BL
GVGV
TB1
PU
YL
F
WH
H C
YL
LPS
HPS
YL/PK
BK
1 5
BL
NOTE 3 & 7
G
T4
EM
L
T3T2T1
C
RD
BK
N
T5
YLWH
TB1
BL
YL/PK
GR
SEENOTE 8
S1S2 R CW1 G
GR
WHRD
BLPU
YL
TO THERMOSTAT
W2
BR
BR
RD
BK
BK
BK
YLPU
BRWH
OR
WH
WH
SEE NOTE 5
3
1
2
7
8
9
BR
RD
SMOKE/FIREDETECTORREPLACES
JUMPER WIRE
++
0140
L029
12-B
38 www.daikinac.com SS-DSG3
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
Wiring Diagram — DSG060*1D SINGLE PHASE 208/230V/60HZ DIRECT DRIVE
AUXILIARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
VMRLS4
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
STATUS LIGHT
3 BLINKS
6 BLINKS
2 BLINKS
4 BLINKS
5 BLINKS
OFF
ON
1 BLINK
OPEN AUX. LIMIT
FALSE FLAME SENSED
OUTPUT DELAY
OPEN LIMIT SWITCH
COMPRESSOR
WITHOUT INDUCER ONPRESSURE SWITCH CLOSED
PRESSURE SWITCHSWITCH
OPEN
OPEN ROLLOUTSWITCH
IGNITION FAILURE
NORMAL OPERATION
NO POWER ORINTERNAL CONTROL
EQUIP. STATUS
OR
OR
FAULT
GR
5
79
Y2Y1
3
6
1210
8
11
RSALS
PS
BAD SWITCHAUX. LIMIT OPEN
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVE
BAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
PRESSURE SWITCH
CHECK
CHECK
GAS PRESSURE
FLAME ROLLOUTFLAME SENSOR
GAS VALVE
CHECK FUSE ON CONTROLCHECK INPUT POWER
REPLACE CONTROLGAS FLOW
CHECK
-
C
4
3 2 1
5 6
GV
IGN
NOTE 6L1
F
H
C
D1
FS
TR
CM CONDENSER MOTOR
NOTE 6
C
T2 T1
T5
T3
T4EM
FSIIC
L2
LS LIMIT SWITCH
VENT MOTOR RELAYVENT MOTOR
PRESSURE SWITCH
TERMINAL BLOCK (24V SIGNAL)ROLLOUT SWITCH
VMRVM
PSPLF
TB1RS
CONTACTOR
GAS VALVE
IGNITOR
EQUIPMENT GROUNDFLAME SENSOR
EVAPORATOR MOTOR
RCCF
FUSEF
C
GV
FSGND
IGNIIC
EM
COMPRESSORCOMPALS
TB1
TB1
TB1
TR TRANSFORMER
C
L2
L2
VMR
T2
SUPPLY VOLTAGE240/1/60
L1
SEE NOTE 22 13
L1C T1
EM
L N
CR
SCOMP
H CRCCF
CM
VM
C
LPS HPS
HIGH PRESSURE SWITCHHPS
LOW PRESSURE SWITCHLPS
COOLING SPEED (YELLOW WIRE)
3. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING SPEED AT MOTOR T4 AND T5 TERMINALS. CHANGE HEATING SPEED AT MOTOR T1. T2, AND T3 TERMINALS
4. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY.
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).
T3 - LOW SPEEDT4 - HIGH SPEED
NOTES
FACTORY WIRING
LOW VOLTAGE
BL
RD
YL
W
BL
G
R
W
NO ECONOMIZER
G
RD
PK
WH
W
R RD
WH
GR
C
R
YL
GRG
WH
C
GR
BL
C
2 STAGE COOLING
TB1
G
R
W
C
TB1
TB1
Y
W
R
G
C
W
Y2
G
R
C
STAT
STAT
STAT
BL/PK BLUE WITH PINK STRIPYL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLE
WH WHITE
BK BLACK
BR BROWN
OR ORANGE
YL YELLOW
6. L1 AND L2 ON ICC CONTROL IS 24V INPUT.7. SPEED TAP TERMINATIONS SHOWN ON DIAGRAM ARE REPRESENTATIVE, BUT ACTUAL FACTORY SETTINGS MAY BE DIFFERENT BASED ON THE HEATING VALUE OF THE UNIT.8. FOR LOW STAGE OPERATION ONLY, REMOVE WHITE JUMPER. FOR 2 STAGE OPERATION, REMOVE JUMPER AND CONNECT W2 TO W2 ON THERMOSTAT.
3 1
AUXILIARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
VMRLS4
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
STATUS LIGHT
3 BLINKS
6 BLINKS
2 BLINKS
4 BLINKS
5 BLINKS
OFF
ON
1 BLINK
OPEN AUX. LIMIT
FALSE FLAME SENSED
OUTPUT DELAY
OPEN LIMIT SWITCH
COMPRESSOR
WITHOUT INDUCER ONPRESSURE SWITCH CLOSED
PRESSURE SWITCHSWITCH
OPEN
OPEN ROLLOUTSWITCH
IGNITION FAILURE
NORMAL OPERATION
NO POWER ORINTERNAL CONTROL
EQUIP. STATUS
OR
OR
FAULT
TO THERMOSTATTERMINAL BLOCK
GR
5
79ECON
IIC
W1 Y1
3
6
1210
8
11
RSALS
PS
BAD SWITCHAUX. LIMIT OPEN
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVE
BAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
PRESSURE SWITCH
CHECK
CHECK
GAS PRESSURE
FLAME ROLLOUTFLAME SENSOR
GAS VALVE
CHECK FUSE ON CONTROLCHECK INPUT POWER
REPLACE CONTROLGAS FLOW
CHECK
-
PLFC
NOTE 4
4
3 2 1
5 6
GV
IGN
NOTE 6L1
F
H
C
D1
FS
TR
CM CONDENSER MOTOR
NOTE 6
C
T2 T1
T5
T3
T4EM
FSIIC
L2
LS LIMIT SWITCH
VENT MOTOR RELAYVENT MOTOR
PRESSURE SWITCH
TERMINAL BLOCK (24V SIGNAL)
VMRVM
PSPLF
TB1RS
RUN CAPACITOR FOR COMPRESSOR/FAN
CONTACTOR
GAS VALVE
IGNITOR
EQUIPMENT GROUNDFLAME SENSOR
EVAPORATOR MOTOR
RCCF
FUSEF
C
GV
FSGND
IGNIIC
EM
COMPRESSOR
COMPONENT LEGEND
COMPALS
TB1
TB1
TB1
TR TRANSFORMER
C
L2
L2
VMR
T2
SUPPLY VOLTAGE240/1/60
L1
SEE NOTE 22 13
L1C T1
EM
L N
CR
SCOMP
H CRCCF
CMF
VM
C
LPS HPS
HIGH PRESSURE SWITCHHPS
LOW PRESSURE SWITCHLPS
++ USE NEC CLASS 2 WIRE.5. USE COPPER CONDUCTORS ONLY.
T3 - LOW SPEEDT4 - HIGH SPEED
HEATING SPEED (WHITE WIRE)
T5 - HIGH SPEED (140)T2 - MED. SPEEDT1 - LOW SPEED (070)
HIGH VOLTAGE
OPTIONAL HIGH VOLTAGEOPTIONAL LOW VOLTAGE
FIELD WIRING
LINE VOLTAGE
LOW VOLTAGE
BL
RD
Y1
YL
W
BL
G
R
W
G
YL
RD
Y1
PK
WH
W
R RD
WH
GR
C
R
YL
GR
Y1
G
WH
WITH ECONOMIZER OPTION
C
GR
THERMOSTATFIELD WIRING
BL
C
TB1
G
R
W
Y
C
TB1
TB1
Y
W
R
G
C
W
Y2
G
R
C
Y1
STAT
STAT
STAT
WIRE CODE
PK PINK
RD RED
SEE UNIT RATING PLATE FOR TYPE AND SIZEOF OVER CURRENT PROTECTION .
W2
3 1
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
78 9
S1 S2
Y2
Y2
Y2
240/1/60 0140L02912-B
EQUIPMENTGROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITERSWITCH (PRESS.)
OVERCURRENTPROT. DEVICE
JUNCTION
TERMINAL
INTERNAL TOINTEGRATED
CONTROL
PLUGCONNECTION
++
++
SS-DSG3 www.daikinac.com 39
Wiring Diagram — DSG036090/DSG048 (090/115)3D* THREE PHASE 208/230V/60HZ DIRECT DRIVE
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
GND
YL
208-240/3/60SEE NOTE 5
RD
YL RD
BREAK FOR TWO STAGE
T2
COMPRESSOR
IIC
C RD
RD
L2C
T2
L1
T1
RD
BK
BK
PU
YL
C22
OR
SPEED-UP
MOUNT
T1
P2
REQUIREDSCREW
P3135120
150
FUSE 3 AMP MAXF1
WH
YL
RD
RD
118129
7 1042 5
631
FS
RD
BK
SEE NOTE 8GREEN JUMPER
COOL
DI
L1HEAT
UNUSEDL2
BL
BK
YLYL
PU
BRBL
RD
YL
WH
GRBL
P1
ECONRD
ALS
GR
PS
RSPLF
YL
YL
NOTE 4
GAS VALVEMV
BL
W. R.GAS VALVE
PU
(ALT.) HONEYWELL
BR
PU
PU
PU
BK
BR
R GY1 W1
OR
RDTO THERMOSTAT
CMV
FS
IGN
VM
BL
RD
BL
BK
GVGV
TB1
YL
BL
YL
GR
Y2
PU
31
RD
RDLS
208TR
BL
24V
C
PK
240
BL
NOTE 2
RD
PU
BK
RD
BL
BL/PK
YL/PK
HPS
LPS
BL
GR
BK
BR
RD
PU
EM
BL
3 SPEED
PU
PU
BR
CM
BK
ALTERNATEMOTOR6-WIRESSEE NOTE 6 & 7
BC
BC3 SPEED
BL
EM
RD
BK
BR
RD
PU
COMP
T1T2T3
SEE NOTE 7
RD
RD
BK
F
W2
BR
L2
T2
L3
T3
POWERSUPPLY
FC
WH
BK
BL
RD
1S 2S
32
6
7
9
1 485
PU
GR
R
R
YL
BR
SEENOTE 9
FOR SMOKE/FIREDETECTOR REPLACEJUMPER
2
0140
L054
04-A
40 www.daikinac.com SS-DSG3
Wiring Diagram — DSG036090/DSG048 (090/115) 3D* THREE PHASE 208/230V/60HZ DIRECT DRIVE
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).
AUXILLARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
STATUS LIGHT
3 BLINKS
6 BLINKS
2 BLINKS
4 BLINKS5 BLINKS
OFF
ON
1 BLINKOPEN AUX. LIMIT
FALSE FLAME SENSED
OUTPUT DELAY
OPEN LIMIT SWITCH
COMPRESSOR
WITHOUT INDUCER ONPRESSURE SWITCH CLOSED
PRESSURE SWITCHSWITCH
OPEN
OPEN ROLLOUTSWITCH
IGNITION FAILURE
NORMAL OPERATIONNO POWER OR
INTERNAL CONTROL
EQUIP. STATUS
OR
OR
FAULT
BAD SWITCHAUX. LIMIT OPEN
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVEBAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
PRESSURE SWITCHCHECK
CHECK
GAS PRESSURE
FLAME ROLLOUTFLAME SENSOR
GAS VALVE
CHECK FUSE ON CONTROLCHECK INPUT POWER
REPLACE CONTROLGAS FLOW
CHECK-
PLF
GV
C
L1208-240/3/60
SUPPLY VOLTAGE
CM CONDENSER MOTOR
L3
LS LIMIT SWITCH
VENT MOTOR RELAYVENT MOTOR
PRESSURE SWITCH
TERMINAL BLOCK (24V SIGNAL)ROLLOUT SWITCH
VMRVM
PSPLF
TB1RS
NOTES
FAN CAPACITOR
CONTACTOR
GAS VALVE
IGNITOR
EQUIPMENT GROUNDFLAME SENSOR
EVAPORATOR MOTOR
FCFUSEF
C
GV
FSGND
IGNIIC
EM
L2 L3COMPRESSOR
COMPONENT LEGEND
COMPALS
TB1
TR TRANSFORMER
L2
C
CM
T3
COMPT3
T2
FC
L1
C T1T1
CT2
208-240/3/60 0140L05404-A
HPS HIGH PRESSURE SWITCH
HIGH VOLTAGE
FACTORY WIRING
OPTIONAL HIGH VOLTAGE
LOW VOLTAGE
FIELD WIRING
LINE VOLTAGE
LOW VOLTAGE
BL
RDY1
YL
W
BL
GR
W
NO ECONOMIZER
G
RDY1
PK
WH
W
R RD
WHGR
C
RYL
GR
Y1
GWH
WITH ECONOMIZER OPTION
C
GR
THERMOSTATFIELD WIRING
BL
C
2 STAGE COOLING
TB1
GR
W
C
TB1
TB1
Y
W
RG
C
W
Y2
GR
C
Y1
STAT
STAT
STAT
BL/PK BLUE WITH PINK STRIPYL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
EM
DI
PCB
HEAT
COOL
FCPCB
LI
IIC
SEE NOTE 22 13
3. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING SPEED AT COOL TERMINAL. CHANGE HEATING SPEED AT HEAT TERMINAL ON CONTROL BOARD
4. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY.
++ USE NEC CLASS 2 WIRE.5. USE COPPER CONDUCTORS ONLY.
7. SPEED TAP TERMINATIONS SHOWN ON DIAGRAM ARE REPRESENTATIVE, BUT ACTUAL FACTORY SETTING MAY BE DIFFERENT BASED ON HEATING VALUE AND CAPACITY OF UNIT.
6. PURPLE WIRE CONNECTS TO TRANSFORMER (PIN 1).
8. TO RUN DIFFERENT SPEED FOR HEATING AND COOLING, DISCONNECT GEEEN JUMPER FROM "COOL" TERMINAL AND REPLACE WITH APPROPRIATE SPEED TAP. THEN PLACE DISCONNECTED END OF JUMPER ON "UNUSED" TERMINAL LEFT OPEN BY MOVING THE SPEED TAP.9. FOR LOW STAGE OPERATION ONLY, REMOVE WHITE JUMPER. FOR 2 STAGE OPERATION, REMOVE JUMPER AND CONNECT W2 TO W1 ON THERMOSTAT.
BLOWER CAPACITORBC
SEE UNIT RATING PLATE FOR TYPE AND SIZE OFOVERCURRENT PROTECTION.
VM
IGN
FFS
TR
FS
TB1
LPS HPS
C
PS
ALS RS
11
8
10 12
6
3
Y2W Y1
ECON9 7
5
R G
TO THERMOSTATTERMINAL BLOCK
4LS
LPS LOW PRESSURE SWITCH
BK - HIGH SPEEDBL - MED. SPEEDRD - LOW SPEED3 SPEED MOTOR
32
6
7
9
1 485
S1 S2
IIC
SEENOTE 4
Y2YL Y
Y2
Y2
EQUIPMENTGROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITERSWITCH (PRESS.)OVERCURRENT
PROT. DEVICE
JUNCTIONTERMINAL
INTERNAL TOINTEGRATED
CONTROLPLUG
CONNECTION
SS-DSG3 www.daikinac.com 41
GND
YL
208-240/3/60SEE NOTE 5
RD
YL RD
BR
EAK
FOR
TWO
STA
GE
T2
CO
MP
RE
SSO
R
IIC
C RD
RD
L2C
T2
L1
T1
RD
BK
BK
PU
YL
C22
OR
SP
EE
D-U
P
MO
UN
T
T1
P2
RE
QU
IRE
DS
CR
EW
P3135
120
150
FUSE 3 AMP MAX
F1
WH
YL
RD
RD
118
1297 104
2 563
1
FS
RD
BK
SEE NOTE 8GREEN JUMPER
CO
OL
DI
L1H
EA
TU
NU
SE
DL2
BL
BK
YLYL
PU
BRBL
RD
PUWH GR
BL
P1
EC
ON
RD
ALS
GR
PS
RSPLF
YL
YL
NOTE 4
GAS VALVE
MV
2
1 4
5
YL
BL
W. R.GAS VALVE
PU
(ALT.) HONEYWELL
3 6
YL
BR
PU
PU
PU
BK
BR
OR
RDTO THERMOSTAT
MV
FS
IGN
VM
BL
RD
BL
BK
GVGV
TB1
PU
BL
YL
GR
YL
31
RD
RDLS
208
TR
BL
24V
C
PK
240
BL
NOTE 2
RD
PU
BK
RD
RD
BL
FOR SMOKE/FIREDETECTORREPLACE JUMPER
BL/PK
YL/PK
HPS
LPS
BL
GR
BK
BR
RD
PU
EM
BL
3 SPEED
PU
PU
BR
CM
BK
ALTERNATEMOTOR6-WIRESSEE NOTE 6 & 7
BC
BC3 SPEED
BL
EM
RD
BK
BR
RD
PU
COMP
T13T 2T
SEE NOTE 7
RD
RD
BK
F
L2
T2
L3
T3
POWERSUPPLY
FC
BK
7
8
9
Y2 Y1S1S2 RC W1 GW2
RD
BL
BR
PK
++
2
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
Wiring Diagram — DSG0360453D*/THREE PHASE 208/230V/60HZ DIRECT DRIVE
0140
L054
06-A
42 www.daikinac.com SS-DSG3
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).
AUXILLARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
LS4
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
STATUS LIGHT
3 BLINKS
6 BLINKS
2 BLINKS
4 BLINKS
5 BLINKS
OFF
ON
1 BLINK
OPEN AUX. LIMIT
FALSE FLAME SENSED
OUTPUT DELAY
OPEN LIMIT SWITCH
COMPRESSOR
WITHOUT INDUCER ON
PRESSURE SWITCHSWITCH
OPEN
OPEN ROLLOUTSWITCH
IGNITION FAILURE
NORMAL OPERATION
NO POWER ORINTERNAL CONTROL
EQUIP. STATUS
OR
OR
FAULT
5
79ECON
IIC3
6
1210
8
11
RSALS
PS
BAD SWITCHAUX. LIMIT OPEN
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVEBAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
PRESSURE SWITCH
CHECK
CHECK
GAS PRESSURE
FLAME ROLLOUTFLAME SENSOR
GAS VALVE
CHECK FUSE ON CONTROLCHECK INPUT POWER
REPLACE CONTROLGAS FLOW
CHECK
-
PLF
NOTE 4
4
3 2 1
5 6
GV
C
L1208-240/3/60
SUPPLY VOLTAGE
CM CONDENSER MOTOR
L3
LS LIMIT SWITCH
VENT MOTOR RELAYVENT MOTOR
PRESSURE SWITCH
TERMINAL BLOCK (24V SIGNAL)ROLLOUT SWITCH
VMRVM
PSPLF
TB1RS
NOTES
FAN CAPACITOR
CONTACTOR
GAS VALVE
IGNITOR
EQUIPMENT GROUNDFLAME SENSOR
EVAPORATOR MOTOR
FCFUSEF
C
GV
FSGND
IGNIIC
EM
L2 L3COMPRESSOR
COMPONENT LEGEND
COMPALS
TR TRANSFORMER
L2
C
CM
T3
COMPT3
T2
FC
L1C T1
T1
CT2
208-240/3/60 0140L05406-A
HPSLPS
HPS HIGH PRESSURE SWITCH
HIGH VOLTAGE
FACTORY WIRING
OPTIONAL HIGH VOLTAGE
LOW VOLTAGE
FIELD WIRING
LINE VOLTAGE
LOW VOLTAGE
BL
RD
Y1
YL
W
BL
G
R
W
NO ECONOMIZER
G
YL
RD
Y2
Y1
PK
WH
W
R RD
WH
GR
C
R
YL
GR
Y1
G
WH
WITH ECONOMIZER OPTION
C
GR
THERMOSTATFIELD WIRING
BL
C
2 STAGE COOLING
TB1
G
R
W
Y
C
TB1
TB1
Y
W
R
G
C
W
Y2
G
R
C
Y1
STAT
STAT
STAT
BL/PK BLUE WITH PINK STRIPYL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
EM
DI
PCB
HEAT
COOL
FCPCB
LI
IICFS
TR
FSF
IGN
SEE NOTE 22 13
VM
3. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING SPEED AT COOL TERMINAL. CHANGE HEATING SPEED AT HEAT TERMINAL ON CONTROL BOARD
4. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY.
USE NEC CLASS 2 WIRE.5. USE COPPER CONDUCTORS ONLY.
7. SPEED TAP TERMINATIONS SHOWN ON DIAGRAM ARE REPRESENTATIVE, BUT ACTUAL FACTORY SETTING MAY BE DIFFERENT BASED ON HEATING VALUE AND CAPACITY OF UNIT.
6. PURPLE WIRE CONNECTS TO TRANSFORMER (PIN 1).
BLOWER CAPACITORBC
SEE UNIT RATING PLATE FOR TYPE AND SIZE OFOVERCURRENT PROTECTION.
8. TO RUN DIFFERENT SPEED FOR HEATING AND COOLING, DISCONNECT GEEEN JUMPER FROM "COOL" TERMINAL AND REPLACE WITH APPROPRIATE SPEED TAP. THEN PLACE DISCONNECTED END OF JUMPER ON "UNUSED" TERMINAL LEFT OPEN BY MOVING THE SPEED TAP.
LPS LOW PRESSURE SWITCH
BK - HIGH SPEEDBL - MED. SPEEDRD - LOW SPEED3 SPEED MOTOR
78 9
TO THERMOSTATTERMINAL BLOCK
GR Y1 CGR W1 Y2Y1 CW2S1 S2
Y2
Y2
EQUIPMENTGROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITER
SWITCH (PRESS.)
OVERCURRENTPROT. DEVICE
JUNCTION
TERMINAL
INTERNAL TOINTEGRATED
CONTROL
PLUG CONNECTION
++
++
++
PRESSURE SWITCH CLOSED
OPTIONAL LOW VOLTAGE
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
Wiring Diagram — DSG0360453D* THREE PHASE 208/230V/60HZ DIRECT DRIVE
SS-DSG3 www.daikinac.com 43
GND
YL
BK
BK
POWER SUPPLY240/3/60
RD
WHBL
BR
EA
K FO
R TW
O S
TAG
E
T2
CO
MPR
ESS
OR
IIC
FC
RD
RD
L2C
T2 T3
L3L1
T1
BK
BK
PU
YL
T3 T2 T1
COMP
BK
PU
CM
BR
VMR
C22
OR
SP
EE
D-U
P
MO
UN
T
T1
P2
RE
QU
IRE
DS
CR
EW
P3135
120
150
FUSE 3 AMP MAX
F1
WH
YL
RD
RD
118
1297 104
2 563
1
FS
RD
BR
NOTE 6SEE
CO
OL
DI
L1H
EA
TU
NU
SE
DL2
BL
WH
YLYL
PU
RD
BL
RD
PU
WH
GR BLBL
BL
P1
EC
ON
RD
ALS
GR
PS
RSPLF
YL
YL
NOTE 4
GAS VALVE
MV
2
1 4
5
YL
BL
W. R.GAS VALVE
PU
(ALT.) HONEYWELL
3 6
YL
BR WH
BL YL
PU
PU
PU
WH
BR
OR
RD
TO THERMOSTAT
MV
FS
IGN
VM
BL
BL
YL
WHBR
BL
BK
GVGV
BK
TB1
PU
BL
YL
LPS
HPS
YL/PK
BL/PK
GR
BL
TB1
WH
YL
NOTE 3 & 7
1 5
RD
YL
31
RD
RDLS
208
TR
BL
24V
C
BL PK
240
BK
RD
BK
BL
NOTE 2RD
BL
G
T4
EM
L
T3T2T1
C
GR
RD
BK
N
T5
GR
BR
BR
NOTE 8SEE
WHYLBR
PUOR
3
1
2
OR
OR
WH
SEE NOTE 5
YL
YL RD
7
8
9
Y2Y1S1S2 RC W1 GW2
WH
BR
RD
PK
SMOKE/FIREDETECTORREPLACES
JUMPER WIRE
++
2
Wiring Diagram — DSG060(090/140)3D* THREE PHASE 208/230V/60HZ DIRECT DRIVE
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
0140
L054
15-A
44 www.daikinac.com SS-DSG3
COOLING SPEED (YELLOW WIRE)
++ USE NEC CLASS 2 WIRE.5. USE COPPER CONDUCTORS ONLY.
6. L1 AND L2 ON ICC CONTROL IS 24V INPUT.7. SPEED TAP TERMINATIONS SHOWN ON DIAGRAM ARE REPRESENTATIVE, BUT ACTUAL FACTORY SETTINGS MAY BE DIFFERENT BASED ON THE HEATING VALUE OF THE UNIT.
3. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING SPEED AT MOTOR T3 AND T4 TERMINALS. CHANGE HEATING SPEED AT MOTOR T1. T2, AND T5 TERMINALS
4. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY.
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).
AUXILIARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
LS4
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
STATUS LIGHT
3 BLINKS
6 BLINKS
2 BLINKS
4 BLINKS
5 BLINKS
OFF
ON
1 BLINK
OPEN AUX. LIMIT
FALSE FLAME SENSED
OUTPUT DELAY
OPEN LIMIT SWITCH
COMPRESSOR
WITHOUT INDUCER ONPRESSURE SWITCH CLOSED
PRESSURE SWITCHSWITCH
OPEN
OPEN ROLLOUTSWITCH
IGNITION FAILURE
NORMAL OPERATIONNO POWER OR
INTERNAL CONTROL
EQUIP. STATUS
OR
OR
FAULT
TO THERMOSTATTERMINAL BLOCK
5
79ECON
IIC3
6
1210
8
11
RSALS
PS
BAD SWITCHAUX. LIMIT OPEN
ANTI-CYCLE TIMER
STICKING GAS VALVEBAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
PRESSURE SWITCHCHECK
CHECK
GAS PRESSURE
FLAME ROLLOUTFLAME SENSOR
GAS VALVE
CHECK FUSE ON CONTROLCHECK INPUT POWER
REPLACE CONTROLGAS FLOW
CHECK
-
PLF
NOTE 44
3 2 1
5 6
GV
C
T3 - LOW SPEEDT4 - HIGH SPEED
IGN
NOTE 6L1
F
D1
FS
TR
L1240/3/60
SUPPLY VOLTAGE
CM CONDENSER MOTOR
NOTE 6
FSIIC
L2
VM1
VMR
L3
LS LIMIT SWITCH
VENT MOTOR RELAYVENT MOTOR
PRESSURE SWITCH
TERMINAL BLOCK (24V SIGNAL)ROLLOUT SWITCH
VMRVM
PSPLF
TB1RS
NOTES
FAN CAPACITOR
CONTACTOR
GAS VALVE
IGNITOR
EQUIPMENT GROUNDFLAME SENSOR
EVAPORATOR MOTOR
FCFUSEF
C
GV
FSGND
IGNIIC
EM
L2 L3
COMPRESSOR
COMPONENT LEGEND
COMPALS
HEATING SPEED (WHITE WIRE)
T5 - HIGH SPEED (140)T2 - MED. SPEEDT1 - LOW SPEED (070)
TB1
TR TRANSFORMER
EM
L
3 12
N
SEE NOTE 2
L2
C
CM
T3
COMPT3
T2
FC
L1C T1
T1
CT2
HPSLPS
HPS HIGH PRESSURE SWITCH
VMR
TB1 54
EM
1
32
CH
NOTE 3
HIGH VOLTAGE
FACTORY WIRING
LOW VOLTAGE
FIELD WIRING
LINE VOLTAGE
LOW VOLTAGE
BL
RD
Y1
YL
W
BL
G
R
W
NO ECONOMIZER
G
YL
RD
Y2
Y1
PK
WH
W
R RD
WH
GR
C
R
YL
GR
Y1
G
WH
WITH ECONOMIZER OPTION
C
GR
THERMOSTATFIELD WIRING
BL
C
2 STAGE COOLING
TB1
G
R
W
Y
C
TB1
TB1
Y
W
R
G
C
W
Y2
G
R
C
Y1
STAT
STAT
STAT
BL/PK BLUE WITH PINK STRIPYL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
SEE UNIT RATING PLATE FOR TYPE AND SIZE OFOVER CURRENT PROTECTION
8. FOR LOW STAGE OPERATION ONLY, REMOVE WHITE JUMPER. FOR 2 STAGE OPERATION, REMOVE JUMPER AND CONNECT W2 TO W2 ON THERMOSTAT.
3
MAIN LIMIT OPEN
LPS LOW PRESSURE SWITCH
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
78 9
GR Y1 CGR W1 Y2Y1 CW2S1 S2
C
Y2
Y2
230/3/60 0140L05415-A
EQUIPMENTGROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITERSWITCH (PRESS.)
OVERCURRENTPROT. DEVICE
JUNCTION
TERMINAL
INTERNAL TOINTEGRATED
CONTROL
PLUGCONNECTION
++
++
OPTIONAL HIGH VOLTAGEOPTIONAL LOW VOLTAGE
Wiring Diagram — DSG060 (090/140)3D* THREE PHASE 208/230V/60HZ DIRECT DRIVE
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
SS-DSG3 www.daikinac.com 45
Wiring Diagram – DSG0360453B* THREE PHASE 208/230V/60HZ BELT DRIVE
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
FALSE FLAME SENSED
OPEN LIMIT SWITCHWITHOUT INDUCER ONPRESSURE SWITCH CLOSED
PRESSURE SWITCH
NORMAL OPERATION
INTERNAL CONTROL
3 BLINKS
6 BLINKS
4 BLINKS5 BLINKS
OUTPUT DELAYCOMPRESSOR
OFF
ON
1 BLINK
2 BLINKS
STATUS LIGHT
OPEN AUX. LIMIT
IGNITION FAILUREOPEN ROLLOUT
SWITCH
OPEN
SWITCH
NO POWER OR
EQUIP. STATUS
CHECK
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVEBAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
GAS PRESSURE
FLAME ROLLOUT
AUX. LIMIT OPEN
FLAME SENSOR
BAD SWITCH
GAS VALVE
REPLACE CONTROLGAS FLOW
PRESSURE SWITCHCHECK
CHECK FUSE ON CONTROLCHECK INPUT POWER
-
CHECK
TRANSFORMERTR
ALS
COMP
COMPONENT LEGEND
COMPRESSOR
EM
IICIGN
GNDFS
GV
C
F FUSEFC
EVAPORATOR MOTOR
FLAME SENSOREQUIPMENT GROUND
IGNITOR
GAS VALVE
CONTACTOR
FAN CAPACITOR
RSTB1
PLFPS
VMVMR
ROLLOUT SWITCHTERMINAL BLOCK (24V SIGNAL)
PRESSURE SWITCH
VENT MOTORVENT MOTOR RELAY
LIMIT SWITCHLS
CONDENSER MOTORCM
INTEGRATED IGNITION CONTROL
FEMALE PLUG/CONNECTOR
AUXILIARY LIMIT SWITCH
IBR INDOOR BLOWER RELAY
GND
T3
RD
L3
POWER SUPPLY
YL
BK
208-240/3/60
YL
IIC
T1 T2BKPUBK
CL1 L2BL
BL
RD RD
BK
T3 T2 T1
PU
COMP
CM
BR BK
RD
RDLS
WH
GR
1079 12
8 11BLPU
RDRD
13
26
54
WH
L1 BR
FS
YL
RD
DI
BL
RDYL
YL
PU
YLPUPS
541
2
NOTE 2PLF
63
YL
RS
ALS
GR
HEATCO
OL
UNUSEDBL L2
MV
MV
PU
PU W. R.GAS VALVE
GVBL
GAS VALVE
GV
GR
OR
RD
BK
OR
EM
WHVMR
BL
24VTR
BLBL
1240
2 3C
BK OR
RD
OR
BL
GR
BC BLOWER CONTACTOR
SEENOTE 3
BC
FS
IGN
BK
VM
OR
RD
L2 L3
C
L2
L3
CMT3
C
FC
208-240/3/60
T2
T3
T2T1
T1 COMP
L1
CL1
SUPPLY VOLTAGE
13
3VMR
BCIIC
VMR
FSIGN
NOTE 3L2
C
RSGV
3
6
2
5
1
EM
LS
H CD1
FS
5
4
L1NOTE 3
ALS
PS
10ECON
3
6
8
12
11
9 7
TR
FCRDBR
1
4
LPS HPS
LPS LOW PRESSURE SWITCH
HPS HIGH PRESSURE SWITCH
RD
T2T3
T1
C
BC
BK
BC
BC
208
L3L2
L1
WH
YL
HPS
LPS
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
USE NEC CLASS 2 WIRE.4. USE COPPER CONDUCTORS ONLY.
2. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).
NOTES
PK
TB1
LOW VOLTAGE
LINE VOLTAGE
FIELD WIRING
LOW VOLTAGE OPTIONAL HIGH VOLTAGE
FACTORY WIRING
HIGH VOLTAGE
BL
RDY1
YL
W
BL
GR
W
NO ECONOMIZER
G
RD
Y2
Y1
PK
WH
W
R RD
WHGR
C
RYL
GR
Y1
GWH
WITH ECONOMIZER OPTION
C
GR
THERMOSTATFIELD WIRING
BL
C
2 STAGE COOLING
TB1
GR
W
C
TB1
TB1
Y
W
RG
C
W
Y2
GR
C
Y1
STAT
STAT
STAT
YL/PK
BL/PK
BL/PK BLUE WITH PINK STRIPYL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
GR
RD
TO THERMOSTAT
3
1
2
F C
OR
OR
SEE NOTE 4
BK
BK
VM
BK
5. FOR 208 VOLT TRANSFORMER OPERATION, MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
FALSE FLAME SENSED
OPEN LIMIT SWITCHWITHOUT INDUCER ONPRESSURE SWITCH CLOSED
PRESSURE SWITCH
NORMAL OPERATION
INTERNAL CONTROL
3 BLINKS
6 BLINKS
4 BLINKS5 BLINKS
OUTPUT DELAYCOMPRESSOR
OFF
ON
1 BLINK
2 BLINKS
STATUS LIGHT
OPEN AUX. LIMIT
IGNITION FAILUREOPEN ROLLOUT
SWITCH
OPEN
SWITCH
NO POWER OR
EQUIP. STATUS
CHECK
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVEBAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
GAS PRESSURE
FLAME ROLLOUT
AUX. LIMIT OPEN
FLAME SENSOR
BAD SWITCH
GAS VALVE
REPLACE CONTROLGAS FLOW
PRESSURE SWITCHCHECK
CHECK FUSE ON CONTROLCHECK INPUT POWER
-
CHECK
TRANSFORMERTR
ALS
COMP
COMPONENT LEGEND
COMPRESSOR
EM
IICIGN
GNDFS
GV
C
F FUSEFC
EVAPORATOR MOTOR
FLAME SENSOREQUIPMENT GROUND
IGNITOR
GAS VALVE
CONTACTOR
FAN CAPACITOR
RSTB1
PLFPS
VMVMR
ROLLOUT SWITCHTERMINAL BLOCK (24V SIGNAL)
PRESSURE SWITCH
VENT MOTORVENT MOTOR RELAY
LIMIT SWITCHLS
CONDENSER MOTORCM
INTEGRATED IGNITION CONTROL
FEMALE PLUG/CONNECTOR
AUXILIARY LIMIT SWITCH
IBR INDOOR BLOWER RELAY
GND
T3
RD
L3
POWER SUPPLY
YL
BK
208-240/3/60
YL
IIC
T1 T2BKPU
YL
BKRD
CL1 L2BL
BL
RD RD
BK
T3 T2 T1
PU
COMP
CM
BR BK
RD
RDLS
WH
GR
1079 12
8 11
ECON
BLPU
RDRD
13
26
54
WH
L1BR
FS
YL
RD
DI
BL
RDYL
YL
GR
YL
PU
YLPUPS
541
2
NOTE 2PLF
63
YL
RS
ALS
GR
HEATCO
OL
UNUSEDBL L2
YL
MV
MV
PU
PU W. R.GAS VALVE
GVBL
(ALT.) HONEYWELLGAS VALVE
GV
GR
OR
RD
BK
OR
EM
WHVMR
BL
24VTR
BLBL
1240
2 3C
BK OR
RD
OR
BL
GR
BC BLOWER CONTACTOR
SEENOTE 3
BC
FS
IGN
BK
VM
OR
RD
L2 L3
C
L2
L3
CMT3
C
FC
208-240/3/60
T2
T3
T2T1
T1 COMP
L1
CL1
SUPPLY VOLTAGE
13
3VMR
BCIIC
VMR
FSIGN
NOTE 3L2
C
RSGV
3
6
PLF 2
5
NOTE 2
1
EM
LS
H CD1
FSF
5
4
L1NOTE 3
ALS
PS
10ECON
3
6
8
12
11
9
IIC
7
TR
FCRDBR
1
4
208-240/3/60 0140L05405-A
LPS HPS
LPS LOW PRESSURE SWITCH
HPS HIGH PRESSURE SWITCH
RD
T2T3
T1
C
BC
BK
BC
BC
208
L3L2
L1
WH
YL
HPS
LPS
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
USE NEC CLASS 2 WIRE.4. USE COPPER CONDUCTORS ONLY.
2. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).
NOTES
PK
SMOKE/FIREDETECTOR REPLACESJUMPER WIRE
LOW VOLTAGE
LINE VOLTAGE
FIELD WIRING
LOW VOLTAGE OPTIONAL HIGH VOLTAGE
FACTORY WIRING
HIGH VOLTAGE
BL
RDY1
YL
W
BL
GR
W
NO ECONOMIZER
G
YL
RDY1
PK
WH
W
R RD
WHGR
C
RYL
GR
Y1
GWH
WITH ECONOMIZER OPTION
C
GR
THERMOSTATFIELD WIRING
BL
C
2 STAGE COOLING
TB1
GR
W
Y
C
TB1
TB1
Y
W
RG
C
W
Y2
GR
C
Y1
STAT
STAT
STAT
YL/PK
BL/PK
BL/PK BLUE WITH PINK STRIPYL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
GR
SEE UNIT RATING PLATE FOR TYPE AND SIZEOF OVER CURRENT PROTECTION
BL
RD
YL BL
RD
TO THERMOSTAT
GR
BL
PU
WH
3
1
2
F C
OR
OR
SEE NOTE 4
BK
BK
VM
BK
5. FOR 208 VOLT TRANSFORMER OPERATION, MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
BLBL
87
9
9 8 7
TO THERMOSTATTERMINAL BLOCK
GR Y2Y1 CGR W1 Y1 CW2S1 S2
Y2Y1S1S2 RC W1 GW2
RD
PK
BR
GR
Y2
Y2
0140
L054
05-A
46 www.daikinac.com SS-DSG3
Wiring Diagram —DSG0360453B* THREE PHASE 208/230V/60HZ BELT DRIVE (cont.)
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
FALSE FLAME SENSED
OPEN LIMIT SWITCHWITHOUT INDUCER ONPRESSURE SWITCH CLOSED
PRESSURE SWITCH
NORMAL OPERATION
INTERNAL CONTROL
3 BLINKS
6 BLINKS
4 BLINKS5 BLINKS
OUTPUT DELAYCOMPRESSOR
OFF
ON
1 BLINK
2 BLINKS
STATUS LIGHT
OPEN AUX. LIMIT
IGNITION FAILUREOPEN ROLLOUT
SWITCH
OPEN
SWITCH
NO POWER OR
EQUIP. STATUS
CHECK
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVEBAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
GAS PRESSURE
FLAME ROLLOUT
AUX. LIMIT OPEN
FLAME SENSOR
BAD SWITCH
GAS VALVE
REPLACE CONTROLGAS FLOW
PRESSURE SWITCHCHECK
CHECK FUSE ON CONTROLCHECK INPUT POWER
-
CHECK
TRANSFORMERTR
ALS
COMP
COMPONENT LEGEND
COMPRESSOR
EM
IICIGN
GNDFS
GV
C
F FUSEFC
EVAPORATOR MOTOR
FLAME SENSOREQUIPMENT GROUND
IGNITOR
GAS VALVE
CONTACTOR
FAN CAPACITOR
RSTB1
PLFPS
VMVMR
ROLLOUT SWITCHTERMINAL BLOCK (24V SIGNAL)
PRESSURE SWITCH
VENT MOTORVENT MOTOR RELAY
LIMIT SWITCHLS
CONDENSER MOTORCM
INTEGRATED IGNITION CONTROL
FEMALE PLUG/CONNECTOR
AUXILIARY LIMIT SWITCH
IBR INDOOR BLOWER RELAY
GND
T3
RD
L3
POWER SUPPLY
YL
BK
208-240/3/60
YL
IIC
T1 T2BKPUBK
CL1 L2BL
BL
RD RD
BK
T3 T2 T1
PU
COMP
CM
BR BK
RD
RDLS
WH
GR
1079 12
8 11BLPU
RDRD
13
26
54
WH
L1 BR
FS
YL
RD
DI
BL
RDYL
YL
PU
YLPUPS
541
2
NOTE 2PLF
63
YL
RS
ALS
GR
HEATCO
OL
UNUSEDBL L2
MV
MV
PU
PU W. R.GAS VALVE
GVBL
GAS VALVE
GV
GR
OR
RD
BK
OR
EM
WHVMR
BL
24VTR
BLBL
1240
2 3C
BK OR
RD
OR
BL
GR
BC BLOWER CONTACTOR
SEENOTE 3
BC
FS
IGN
BK
VM
OR
RD
L2 L3
C
L2
L3
CMT3
C
FC
208-240/3/60
T2
T3
T2T1
T1 COMP
L1
CL1
SUPPLY VOLTAGE
13
3VMR
BCIIC
VMR
FSIGN
NOTE 3L2
C
RSGV
3
6
2
5
1
EM
LS
H CD1
FS
5
4
L1NOTE 3
ALS
PS
10ECON
3
6
8
12
11
9 7
TR
FCRDBR
1
4
LPS HPS
LPS LOW PRESSURE SWITCH
HPS HIGH PRESSURE SWITCH
RD
T2T3
T1
C
BC
BK
BC
BC
208
L3L2
L1
WH
YL
HPS
LPS
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
USE NEC CLASS 2 WIRE.4. USE COPPER CONDUCTORS ONLY.
2. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).
NOTES
PK
TB1
LOW VOLTAGE
LINE VOLTAGE
FIELD WIRING
LOW VOLTAGE OPTIONAL HIGH VOLTAGE
FACTORY WIRING
HIGH VOLTAGE
BL
RDY1
YL
W
BL
GR
W
NO ECONOMIZER
G
RD
Y2
Y1
PK
WH
W
R RD
WHGR
C
RYL
GR
Y1
GWH
WITH ECONOMIZER OPTION
C
GR
THERMOSTATFIELD WIRING
BL
C
2 STAGE COOLING
TB1
GR
W
C
TB1
TB1
Y
W
RG
C
W
Y2
GR
C
Y1
STAT
STAT
STAT
YL/PK
BL/PK
BL/PK BLUE WITH PINK STRIPYL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
GR
RD
TO THERMOSTAT
3
1
2
F C
OR
OR
SEE NOTE 4
BK
BK
VM
BK
5. FOR 208 VOLT TRANSFORMER OPERATION, MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
FALSE FLAME SENSED
OPEN LIMIT SWITCHWITHOUT INDUCER ONPRESSURE SWITCH CLOSED
PRESSURE SWITCH
NORMAL OPERATION
INTERNAL CONTROL
3 BLINKS
6 BLINKS
4 BLINKS5 BLINKS
OUTPUT DELAYCOMPRESSOR
OFF
ON
1 BLINK
2 BLINKS
STATUS LIGHT
OPEN AUX. LIMIT
IGNITION FAILUREOPEN ROLLOUT
SWITCH
OPEN
SWITCH
NO POWER OR
EQUIP. STATUS
CHECK
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVEBAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
GAS PRESSURE
FLAME ROLLOUT
AUX. LIMIT OPEN
FLAME SENSOR
BAD SWITCH
GAS VALVE
REPLACE CONTROLGAS FLOW
PRESSURE SWITCHCHECK
CHECK FUSE ON CONTROLCHECK INPUT POWER
-
CHECK
TRANSFORMERTR
ALS
COMP
COMPONENT LEGEND
COMPRESSOR
EM
IICIGN
GNDFS
GV
C
F FUSEFC
EVAPORATOR MOTOR
FLAME SENSOREQUIPMENT GROUND
IGNITOR
GAS VALVE
CONTACTOR
FAN CAPACITOR
RSTB1
PLFPS
VMVMR
ROLLOUT SWITCHTERMINAL BLOCK (24V SIGNAL)
PRESSURE SWITCH
VENT MOTORVENT MOTOR RELAY
LIMIT SWITCHLS
CONDENSER MOTORCM
INTEGRATED IGNITION CONTROL
FEMALE PLUG/CONNECTOR
AUXILIARY LIMIT SWITCH
IBR INDOOR BLOWER RELAY
GND
T3
RD
L3
POWER SUPPLY
YL
BK
208-240/3/60
YL
IIC
T1 T2BKPU
YL
BKRD
CL1 L2BL
BL
RD RD
BK
T3 T2 T1
PU
COMP
CM
BR BK
RD
RDLS
WH
GR
1079 12
8 11
ECON
BLPU
RDRD
13
26
54
WH
L1BR
FS
YL
RD
DI
BL
RDYL
YL
GR
YL
PU
YLPUPS
541
2
NOTE 2PLF
63
YL
RS
ALS
GR
HEATCO
OL
UNUSEDBL L2
YL
MV
MV
PU
PU W. R.GAS VALVE
GVBL
(ALT.) HONEYWELLGAS VALVE
GV
GR
OR
RD
BK
OR
EM
WHVMR
BL
24VTR
BLBL
1240
2 3C
BK OR
RD
OR
BL
GR
BC BLOWER CONTACTOR
SEENOTE 3
BC
FS
IGN
BK
VM
OR
RD
L2 L3
C
L2
L3
CMT3
C
FC
208-240/3/60
T2
T3
T2T1
T1 COMP
L1
CL1
SUPPLY VOLTAGE
13
3VMR
BCIIC
VMR
FSIGN
NOTE 3L2
C
RSGV
3
6
PLF 2
5
NOTE 2
1
EM
LS
H CD1
FSF
5
4
L1NOTE 3
ALS
PS
10ECON
3
6
8
12
11
9
IIC
7
TR
FCRDBR
1
4
208-240/3/60 0140L05405-A
LPS HPS
LPS LOW PRESSURE SWITCH
HPS HIGH PRESSURE SWITCH
RD
T2T3
T1
C
BC
BK
BC
BC
208
L3L2
L1
WH
YL
HPS
LPS
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
USE NEC CLASS 2 WIRE.4. USE COPPER CONDUCTORS ONLY.
2. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).
NOTES
PK
SMOKE/FIREDETECTOR REPLACESJUMPER WIRE
LOW VOLTAGE
LINE VOLTAGE
FIELD WIRING
LOW VOLTAGE OPTIONAL HIGH VOLTAGE
FACTORY WIRING
HIGH VOLTAGE
BL
RDY1
YL
W
BL
GR
W
NO ECONOMIZER
G
YL
RDY1
PK
WH
W
R RD
WHGR
C
RYL
GR
Y1
GWH
WITH ECONOMIZER OPTION
C
GR
THERMOSTATFIELD WIRING
BL
C
2 STAGE COOLING
TB1
GR
W
Y
C
TB1
TB1
Y
W
RG
C
W
Y2
GR
C
Y1
STAT
STAT
STAT
YL/PK
BL/PK
BL/PK BLUE WITH PINK STRIPYL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
GR
SEE UNIT RATING PLATE FOR TYPE AND SIZEOF OVER CURRENT PROTECTION
BL
RD
YL BL
RD
TO THERMOSTAT
GR
BL
PU
WH
3
1
2
F C
OR
OR
SEE NOTE 4
BK
BK
VM
BK
5. FOR 208 VOLT TRANSFORMER OPERATION, MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
BLBL
87
9
9 8 7
TO THERMOSTATTERMINAL BLOCK
GR Y2Y1 CGR W1 Y1 CW2S1 S2
Y2Y1S1S2 RC W1 GW2
RD
PK
BR
GR
Y2
Y2
SS-DSG3 www.daikinac.com 47
Wiring Diagram — DSG(036/048/060)090 3B*, DSG0481153B*, DSG0601403B* THREE PHASE 208/230V BELT DRIVE
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
FALSE FLAME SENSED
OPEN LIMIT SWITCHWITHOUT INDUCER ON
PRESSURE SWITCH CLOSED
PRESSURE SWITCH
NORMAL OPERATION
3 BLINKS
6 BLINKS
4 BLINKS
5 BLINKS
OUTPUT DELAYCOMPRESSOR
OFF
ON
1 BLINK
2 BLINKS
STATUS LIGHT
OPEN AUX. LIMIT
IGNITION FAILURE
OPEN ROLLOUT
SWITCH
OPEN
SWITCH
NO POWER ORINTERNAL CONTROL
EQUIP. STATUS
CHECK
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVEBAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
GAS PRESSURE
FLAME ROLLOUT
AUX. LIMIT OPEN
FLAME SENSOR
BAD SWITCH
GAS VALVE
REPLACE CONTROLGAS FLOW
PRESSURE SWITCHCHECK
CHECK FUSE ON CONTROLCHECK INPUT POWER
-
CHECK
TRANSFORMERTR
ALS
COMP
COMPONENT LEGEND
COMPRESSOR
EM
IICIGN
GNDFS
GV
C
F FUSEFC
EVAPORATOR MOTOR
FLAME SENSOREQUIPMENT GROUND
IGNITOR
GAS VALVE
CONTACTOR
FAN CAPACITOR
RSTB1
PLFPS
VMVMR
ROLLOUT SWITCHTERMINAL BLOCK (24V SIGNAL)
PRESSURE SWITCH
VENT MOTORVENT MOTOR RELAY
LIMIT SWITCHLS
CONDENSER MOTORCM
INTEGRATED IGNITION CONTROL
FEMALE PLUG/CONNECTOR
AUXILIARY LIMIT SWITCH
IBR INDOOR BLOWER RELAY
GND
T3
RD
L3
POWER SUPPLY
YL
BK
208-240/3/60
YL
IIC
T1 T2BKPU
YL
BK
RD
CL1 L2BL
BL
RD RD
BK
T3 T2 T1
PU
COMP
CM
BR BK
RD
RDLS
WH
GR
1079 12
8 11
ECON
BLPU
RDRD
13
26
54
WH
L1BR
FS
YL
RD
DI
BL
RDYL
YL
GR
YL
PU
YLPU
PS
541
2
NOTE 2PLF
63
YL
RS
ALS
GR
HEATCO
OL
UNUSED
BL
BL L2
BL
YL
MV
MV
PU
PU W. R.GAS VALVE
GV
BR
BL
(ALT.) HONEYWELLGAS VALVE
GV
GR
OR
RD
BK
OR
EM
WH
VMR
BL
24VTR
BLBL
1240
2 3C
BK
OR
RD
OR
BL
GR
BC BLOWER CONTACTOR
SEENOTE 3
BC
FS
IGN
BK
VM
OR
RD
L2 L3
C
L2
L3
CMT3
C
FC
208-240/3/60
T2
T3
T2T1
T1 COMP
L1
CL1
SUPPLY VOLTAGE
3VMR
BCIIC
VMR
FSIGN
NOTE 3L2
C
RSGV
3
6
PLF2
5
NOTE 2
1
EM
LS
H CD1
FSF
5
4
L1NOTE 3
ALS
PS
10ECON
3
6
8
12
11
9
IIC
7
TR
FCRDBR
1
4
208-240/3/60 0140L05401-A
LPS HPS
LPS LOW PRESSURE SWITCH
HPS HIGH PRESSURE SWITCH
RD
T2T3
T1
C
BC
BK
BC
BC
208
L3L2
L1
YL
HPS
LPS
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
USE NEC CLASS 2 WIRE.
2. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR
COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).
NOTES
PK
SMOKE/FIREDETECTORREPLACESJUMPER WIRE
BR
LOW VOLTAGE
LINE VOLTAGE
FIELD WIRING
LOW VOLTAGE OPTIONAL HIGH VOLTAGE
FACTORY WIRING
HIGH VOLTAGE
BL
RDY1
YL
W
BL
GR
W
NO ECONOMIZER
G
YL
RD
Y2
Y1
PK
WH
W
R RD
WHGR
C
RYL
GR
Y1
GWH
WITH ECONOMIZER OPTION
C
GR
THERMOSTATFIELD WIRING
BL
C
2 STAGE COOLING
TB1
GR
W
Y
C
TB1
TB1
Y
W
RG
C
W
Y2
GR
C
Y1
STAT
STAT
STAT
YL/PK
BL/PK
BL/PK BLUE WITH PINK STRIPYL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
GR
SEE UNIT RATING PLATE FOR TYPE AND SIZEOF OVER CURRENT PROTECTION
4. USE COPPER CONDUCTORS ONLY.
6. FOR LOW STAGE OPERATION ONLY, REMOVEWHITE JUMPER. FOR 2 STAGE OPERATION,REMOVE JUMPER AND CONNECT W2 TO W2
ON THERMOSTAT.
BL
RD
YL
RD
TO THERMOSTAT
GR
BL
PU
WH
BR
SEE NOTE 6
3
1
2
OR
OR
WH
SEE NOTE 4
3 1 VM
BK
BK
BK
5. FOR 208 VOLT TRANSFORMER OPERATION,MOVE BLACK WIRE FROM TERMINAL 3 TO
TERMINAL 2 ON TRANSFORMER.
87
9
BL
9 8 7
GR Y2Y1 CGR W1 Y1 CW2S1 S2
TO THERMOSTATTERMINAL BLOCK
Y2Y1S1S2 RC W1 GW2
WH
PUPK
RD
GR
Y2
Y2
0140
L054
01-A
48 www.daikinac.com SS-DSG3
Wiring Diagram — DSG(036/048/060)090 3B*, DSG0481153B*, DSG0601403B* THREE PHASE 208/230V BELT DRIVE (cont.)
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
FALSE FLAME SENSED
OPEN LIMIT SWITCHWITHOUT INDUCER ON
PRESSURE SWITCH CLOSED
PRESSURE SWITCH
NORMAL OPERATION
3 BLINKS
6 BLINKS
4 BLINKS
5 BLINKS
OUTPUT DELAYCOMPRESSOR
OFF
ON
1 BLINK
2 BLINKS
STATUS LIGHT
OPEN AUX. LIMIT
IGNITION FAILURE
OPEN ROLLOUT
SWITCH
OPEN
SWITCH
NO POWER ORINTERNAL CONTROL
EQUIP. STATUS
CHECK
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVEBAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
GAS PRESSURE
FLAME ROLLOUT
AUX. LIMIT OPEN
FLAME SENSOR
BAD SWITCH
GAS VALVE
REPLACE CONTROLGAS FLOW
PRESSURE SWITCHCHECK
CHECK FUSE ON CONTROLCHECK INPUT POWER
-
CHECK
TRANSFORMERTR
ALS
COMP
COMPONENT LEGEND
COMPRESSOR
EM
IICIGN
GNDFS
GV
C
F FUSEFC
EVAPORATOR MOTOR
FLAME SENSOREQUIPMENT GROUND
IGNITOR
GAS VALVE
CONTACTOR
FAN CAPACITOR
RSTB1
PLFPS
VMVMR
ROLLOUT SWITCHTERMINAL BLOCK (24V SIGNAL)
PRESSURE SWITCH
VENT MOTORVENT MOTOR RELAY
LIMIT SWITCHLS
CONDENSER MOTORCM
INTEGRATED IGNITION CONTROL
FEMALE PLUG/CONNECTOR
AUXILIARY LIMIT SWITCH
IBR INDOOR BLOWER RELAY
GND
T3
RD
L3
POWER SUPPLY
YL
BK
208-240/3/60
YL
IIC
T1 T2BKPU
YL
BK
RD
CL1 L2BL
BL
RD RD
BK
T3 T2 T1
PU
COMP
CM
BR BK
RD
RDLS
WH
GR
1079 12
8 11
ECON
BLPU
RDRD
13
26
54
WH
L1BR
FS
YL
RD
DI
BL
RDYL
YL
GR
YL
PU
YLPU
PS
541
2
NOTE 2PLF
63
YL
RS
ALS
GR
HEATCO
OL
UNUSED
BL
BL L2
BL
YL
MV
MV
PU
PU W. R.GAS VALVE
GV
BR
BL
(ALT.) HONEYWELLGAS VALVE
GV
GR
OR
RD
BK
OR
EM
WH
VMR
BL
24VTR
BLBL
1240
2 3C
BK
OR
RD
OR
BL
GR
BC BLOWER CONTACTOR
SEENOTE 3
BC
FS
IGN
BK
VM
OR
RD
L2 L3
C
L2
L3
CMT3
C
FC
208-240/3/60
T2
T3
T2T1
T1 COMP
L1
CL1
SUPPLY VOLTAGE
3VMR
BCIIC
VMR
FSIGN
NOTE 3L2
C
RSGV
3
6
PLF2
5
NOTE 2
1
EM
LS
H CD1
FSF
5
4
L1NOTE 3
ALS
PS
10ECON
3
6
8
12
11
9
IIC
7
TR
FCRDBR
1
4
208-240/3/60 0140L05401-A
LPS HPS
LPS LOW PRESSURE SWITCH
HPS HIGH PRESSURE SWITCH
RD
T2T3
T1
C
BC
BK
BC
BC
208
L3L2
L1
YL
HPS
LPS
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
USE NEC CLASS 2 WIRE.
2. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR
COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).
NOTES
PK
SMOKE/FIREDETECTORREPLACESJUMPER WIRE
BR
LOW VOLTAGE
LINE VOLTAGE
FIELD WIRING
LOW VOLTAGE OPTIONAL HIGH VOLTAGE
FACTORY WIRING
HIGH VOLTAGE
BL
RDY1
YL
W
BL
GR
W
NO ECONOMIZER
G
YL
RD
Y2
Y1
PK
WH
W
R RD
WHGR
C
RYL
GR
Y1
GWH
WITH ECONOMIZER OPTION
C
GR
THERMOSTATFIELD WIRING
BL
C
2 STAGE COOLING
TB1
GR
W
Y
C
TB1
TB1
Y
W
RG
C
W
Y2
GR
C
Y1
STAT
STAT
STAT
YL/PK
BL/PK
BL/PK BLUE WITH PINK STRIPYL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
GR
SEE UNIT RATING PLATE FOR TYPE AND SIZEOF OVER CURRENT PROTECTION
4. USE COPPER CONDUCTORS ONLY.
6. FOR LOW STAGE OPERATION ONLY, REMOVEWHITE JUMPER. FOR 2 STAGE OPERATION,REMOVE JUMPER AND CONNECT W2 TO W2
ON THERMOSTAT.
BL
RD
YL
RD
TO THERMOSTAT
GR
BL
PU
WH
BR
SEE NOTE 6
3
1
2
OR
OR
WH
SEE NOTE 4
3 1 VM
BK
BK
BK
5. FOR 208 VOLT TRANSFORMER OPERATION,MOVE BLACK WIRE FROM TERMINAL 3 TO
TERMINAL 2 ON TRANSFORMER.
87
9
BL
9 8 7
GR Y2Y1 CGR W1 Y1 CW2S1 S2
TO THERMOSTATTERMINAL BLOCK
Y2Y1S1S2 RC W1 GW2
WH
PUPK
RD
GR
Y2
Y2
SS-DSG3 www.daikinac.com 49
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
Wiring Diagram — DSG0360454B* THREE PHASE 460V/60HZ BELT DRIVE
BK
OR
CF
SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION.
SUPPLY VOLTAGE460-575/3/60
BL
NOTE 3SEE
GR
WH
W1
RD
R
BL
C Y1S2 G
TO THERMOSTAT
575
575/3/60460/3/60
SEE NOTE 4
POWER SUPPLY
GR
YL YELLOW
OR ORANGE
BR BROWN
RD RED
BK BLACK
WH WHITE
PK PINKPU PURPLE
BL BLUE
WIRE CODE
GR GREEN
YL/PK YELLOW WITH PINK STRIPBL/PK BLUE WITH PINK STRIP
YL/PK
BL/PK
STAT
STAT
STAT
Y1
C
RG
Y2
W
C
GR
W
Y
TB1
TB1
C
Y
W
RG
TB1
2 STAGE COOLING
C
BL
THERMOSTATFIELD WIRING
GR
C
WITH ECONOMIZER OPTION
WHG
Y1
GR
YLR
C
GRWH
RDR
W
WH
PK
Y1
Y2
RD
YL
G
NO ECONOMIZER
W
RG
BL
W
YL
Y1RD
BL
OR
RDBK OR
WH
BKOR
L3L2
L1
LPS
HPS
OR
RD
BC
BC
BK
BC
C
T3T1
T2
PK
RD
BR
HIGH PRESSURE SWITCHHPS
LOW PRESSURE SWITCHLPS
HPSLPS
460-575/3/60 0140L05407-A
BR RDFC
TR
7
G
TO THERMOSTAT
R
IIC
9
Y1W
11
12
8
6
3
ECON10
PS
ALS
NOTE 3L1
4
5
F FS
D1CH
LS
VM
EM
1
C
GVRS
C
L2NOTE 3
IGNFS
VMR
IICBC
VMR
3
1 3
L1C
L1
COMPT1T1
T2
T3
T2
FC
C
T3CM
L3
L2
C
L3L2
RD
OR
VM
BK
IGN
FS
BC
NOTE 3SEE
YL
BLOWER CONTACTORBC
ORBK
460/575TR240
C460
BLBL
TR
24V
BL
VMR
3
1
2
WHRD
EM
OR
BK
RD
OR
GR
GV
GAS VALVE(ALT.) HONEYWELL
BL
BL
GV
GAS VALVEW. R.
PU
PU
MV
MV BL
L2BL
BL
UNUSEDCO
OL
HEAT GR
ALS
RS
YL
PLFNOTE 2
PS
PU YL
PU
YLYL
BL
DI
RD
YL
FS
BRL1
WH
45
62
31
RDRD
RD
PUBL
ECON
118129
7 10
GR
WH
LSRD
RD
BKBR
CM
COMP
PU
T1T2T3
BK
BK OR
RD
BL
BLL2L1 C
RDBK
YL
PUBK
T2T1
IIC
YL
GR
BK
YL
L3
OR
RD
T3
GND
INDOOR BLOWER RELAYIBR
AUXILLARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
CM CONDENSER MOTOR
LS LIMIT SWITCH
VENT MOTOR RELAYVENT MOTOR
PRESSURE SWITCH
TERMINAL BLOCK (24V SIGNAL)ROLLOUT SWITCH
VMRVM
PSPLF
TB1RS
FAN CAPACITOR
CONTACTOR
GAS VALVE
IGNITOR
EQUIPMENT GROUNDFLAME SENSOR
EVAPORATOR MOTOR
FCFUSEF
C
GV
FSGND
IGNIIC
EM
COMPRESSOR
COMPONENT LEGEND
COMP
ALS
OPTIONAL HIGH VOLTAGE
HIGH VOLTAGE
FIELD WIRING
LOW VOLTAGE
LINE VOLTAGE
FACTORYWIRING
LOW VOLTAGE
TR TRANSFORMER
NOTES
CHECK
-CHECK INPUT POWER
CHECKPRESSURE SWITCH
GAS FLOWREPLACE CONTROL
GAS VALVE
BAD SWITCH
FLAME SENSOR
AUX. LIMIT OPEN
FLAME ROLLOUT
GAS PRESSURE
PRESSURE SWITCH
3 MIN. COMP.
BAD SWITCHSTICKING GAS VALVE
MAIN LIMIT OPEN
ANTI-CYCLE TIMER
CHECK
EQUIP. STATUS
NO POWER OR
SWITCH
OPEN
SWITCH
OPEN ROLLOUTIGNITION FAILURE
OPEN AUX. LIMIT
STATUS LIGHT
2 BLINKS
1 BLINK
ONOFF
COMPRESSOROUTPUT DELAY
5 BLINKS
4 BLINKS
6 BLINKS
3 BLINKS
INTERNAL CONTROL
NORMAL OPERATION
PRESSURE SWITCH
PRESSURE SWITCH CLOSEDWITHOUT INDUCER ONOPEN LIMIT SWITCH
FALSE FLAME SENSED
THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TOTROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:
INSTALLER/SERVICEMAN
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL.
(USE COPPER CONDUCTOR ONLY).
2. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.
4. USE COPPER CONDUCTORS ONLY.++ USE NEC CLASS 2 WIRE.
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
RD
5 841
9
7
623
GR
GR
YL
BL
BL BL
Y2
PU
S1
BR
BR
PK
PK
YL
BL
R
R
FOR SMOKE/FIREDETECTOR JUMPER
S2S1Y25 841
9
7
623
TERMINAL BLOCK
PU
PLF
Y2
Y2
EQUIPMENTGROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITERSWITCH (PRESS.)
OVERCURRENTPROT. DEVICE
JUNCTIONTERMINAL
INTERNAL TOINTEGRATED
CONTROLPLUG
CONNECTION
++
++
++
OPTIONAL LOW VOLTAGE
CHECK FUSE ON CONTROL
SEENOTE 2
1 2 3
0140
L054
07-A
50 www.daikinac.com SS-DSG3
Wiring Diagram — DSG0360454B* THREE PHASE 460V/60HZ BELT DRIVE (cont.)
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
BK
OR
CF
SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION.
SUPPLY VOLTAGE460-575/3/60
BL
NOTE 3SEE
GR
WH
W1
RD
R
BL
C Y1S2 G
TO THERMOSTAT
575
575/3/60460/3/60
SEE NOTE 4
POWER SUPPLY
GR
YL YELLOW
OR ORANGE
BR BROWN
RD RED
BK BLACK
WH WHITE
PK PINKPU PURPLE
BL BLUE
WIRE CODE
GR GREEN
YL/PK YELLOW WITH PINK STRIPBL/PK BLUE WITH PINK STRIP
YL/PK
BL/PK
STAT
STAT
STAT
Y1
C
RG
Y2
W
C
GR
W
Y
TB1
TB1
C
Y
W
RG
TB1
2 STAGE COOLING
C
BL
THERMOSTATFIELD WIRING
GR
C
WITH ECONOMIZER OPTION
WHG
Y1
GR
YLR
C
GRWH
RDR
W
WH
PK
Y1
Y2
RD
YL
G
NO ECONOMIZER
W
RG
BL
W
YL
Y1RD
BL
OR
RDBK OR
WH
BKOR
L3L2
L1
LPS
HPS
OR
RD
BC
BC
BK
BC
C
T3T1
T2
PK
RD
BR
HIGH PRESSURE SWITCHHPS
LOW PRESSURE SWITCHLPS
HPSLPS
460-575/3/60 0140L05407-A
BR RDFC
TR
7
G
TO THERMOSTAT
R
IIC
9
Y1W
11
12
8
6
3
ECON10
PS
ALS
NOTE 3L1
4
5
F FS
D1CH
LS
VM
EM
1
C
GVRS
C
L2NOTE 3
IGNFS
VMR
IICBC
VMR
3
1 3
L1C
L1
COMPT1T1
T2
T3
T2
FC
C
T3CM
L3
L2
C
L3L2
RD
OR
VM
BK
IGN
FS
BC
NOTE 3SEE
YL
BLOWER CONTACTORBC
ORBK
460/575TR240
C460
BLBL
TR
24V
BL
VMR
3
1
2
WHRD
EM
OR
BK
RD
OR
GR
GV
GAS VALVE(ALT.) HONEYWELL
BL
BL
GV
GAS VALVEW. R.
PU
PU
MV
MV BL
L2BL
BL
UNUSEDCO
OL
HEAT GR
ALS
RS
YL
PLFNOTE 2
PS
PU YL
PU
YLYL
BL
DI
RD
YL
FS
BRL1
WH
45
62
31
RDRD
RD
PUBL
ECON
118129
7 10
GR
WH
LSRD
RD
BKBR
CM
COMP
PU
T1T2T3
BK
BK OR
RD
BL
BLL2L1 C
RDBK
YL
PUBK
T2T1
IIC
YL
GR
BK
YL
L3
OR
RD
T3
GND
INDOOR BLOWER RELAYIBR
AUXILLARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
CM CONDENSER MOTOR
LS LIMIT SWITCH
VENT MOTOR RELAYVENT MOTOR
PRESSURE SWITCH
TERMINAL BLOCK (24V SIGNAL)ROLLOUT SWITCH
VMRVM
PSPLF
TB1RS
FAN CAPACITOR
CONTACTOR
GAS VALVE
IGNITOR
EQUIPMENT GROUNDFLAME SENSOR
EVAPORATOR MOTOR
FCFUSEF
C
GV
FSGND
IGNIIC
EM
COMPRESSOR
COMPONENT LEGEND
COMP
ALS
OPTIONAL HIGH VOLTAGE
HIGH VOLTAGE
FIELD WIRING
LOW VOLTAGE
LINE VOLTAGE
FACTORYWIRING
LOW VOLTAGE
TR TRANSFORMER
NOTES
CHECK
-CHECK INPUT POWER
CHECKPRESSURE SWITCH
GAS FLOWREPLACE CONTROL
GAS VALVE
BAD SWITCH
FLAME SENSOR
AUX. LIMIT OPEN
FLAME ROLLOUT
GAS PRESSURE
PRESSURE SWITCH
3 MIN. COMP.
BAD SWITCHSTICKING GAS VALVE
MAIN LIMIT OPEN
ANTI-CYCLE TIMER
CHECK
EQUIP. STATUS
NO POWER OR
SWITCH
OPEN
SWITCH
OPEN ROLLOUTIGNITION FAILURE
OPEN AUX. LIMIT
STATUS LIGHT
2 BLINKS
1 BLINK
ONOFF
COMPRESSOROUTPUT DELAY
5 BLINKS
4 BLINKS
6 BLINKS
3 BLINKS
INTERNAL CONTROL
NORMAL OPERATION
PRESSURE SWITCH
PRESSURE SWITCH CLOSEDWITHOUT INDUCER ONOPEN LIMIT SWITCH
FALSE FLAME SENSED
THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TOTROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:
INSTALLER/SERVICEMAN
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL.
(USE COPPER CONDUCTOR ONLY).
2. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.
4. USE COPPER CONDUCTORS ONLY.++ USE NEC CLASS 2 WIRE.
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
RD
5 841
9
7
623
GR
GR
YL
BL
BL BL
Y2
PU
S1
BR
BR
PK
PK
YL
BL
R
R
FOR SMOKE/FIREDETECTOR JUMPER
S2S1Y25 841
9
7
623
TERMINAL BLOCK
PU
PLF
Y2
Y2
EQUIPMENTGROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITERSWITCH (PRESS.)
OVERCURRENTPROT. DEVICE
JUNCTIONTERMINAL
INTERNAL TOINTEGRATED
CONTROLPLUG
CONNECTION
++
++
++
OPTIONAL LOW VOLTAGE
CHECK FUSE ON CONTROL
SEENOTE 2
SS-DSG3 www.daikinac.com 51
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
Wiring Diagram — DSG(036/060) 090 (4B/7B), DSG0480904B, DSG048115(4B/7B), DSG060140(4B/7B) THREE PHASE 460V/575V BELT DRIVE
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
USE NEC CLASS 2 WIRE.4. USE COPPER CONDUCTORS ONLY.
2. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
FALSE FLAMESENSED
OPEN LIMIT SWITCHWITHOUT INDUCER ONPRESSURE SWITCH CLOSED
PRESSURE SWITCH
NORMAL OPERATION
INTERNAL CONTROL
3 BLINKS
6 BLINKS
4 BLINKS5 BLINKS
OUTPUT DELAYCOMPRESSOR
OFF
ON
1 BLINK
2 BLINKS
STATUS LIGHT
OPEN AUX. LIMIT
IGNITION FAILUREOPEN ROLLOUT
SWITCH
OPEN
SWITCH
NO POWER OR
EQUIP. STATUS
CHECK
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVEBAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
GAS PRESSURE
FLAME ROLLOUT
AUX. LIMIT OPEN
FLAME SENSOR
BAD SWITCH
GAS VALVE
REPLACE CONTROLGAS FLOW
PRESSURE SWITCHCHECK
CHECK FUSE ON CONTROLCHECK INPUT POWER
-CHECK
NOTES
TRANSFORMERTR
LOW VOLTAGE
FACTORY WIRING LINE VOLTAGE
LOW VOLTAGE
FIELD WIRING HIGH VOLTAGE
OPTIONAL HIGH VOLTAGE
ALS
COMP
COMPONENT LEGEND
COMPRESSOR
EM
IICIGN
GNDFS
GV
C
F FUSEFC
EVAPORATOR MOTOR
FLAME SENSOREQUIPMENT GROUND
IGNITOR
GAS VALVE
CONTACTOR
FAN CAPACITOR
RSTB1
PLFPS
VMVMR
ROLLOUT SWITCHTERMINAL BLOCK (24V SIGNAL)
PRESSURE SWITCH
VENT MOTORVENT MOTOR RELAY
LIMIT SWITCHLS
CONDENSER MOTORCM
INTEGRATED IGNITION CONTROL
FEMALE PLUG/CONNECTOR
AUXILLARY LIMIT SWITCH
IBR INDOOR BLOWER RELAY
GND
T3
RD
OR
L3
YL
BK
GR
YL
IIC
T1 T2BKPU
YL
BKRD
CL1 L2BL
BL
RD
ORBK
BK
T3 T2 T1
PU
COMP
CM
BR BK
RD
RDLS
WH
GR
1079 12
8 11
ECON
BLPU
RDRD
RD
13
26
54
WH
L1BR
FS
YL
RD
DI
BL
YL
YL
BL
YL
PU
YLPUPS
541
2
NOTE 2PLF
63
YL
RS
ALS
GR
HEATCOOL
UNUSED
BL
BL L2
BL
YL
MV
MV
PU
PU W. R.GAS VALVE
GV
BL
BL
(ALT.) HONEYWELLGAS VALVE
GV
GR
OR
RD
BK
OR
EM
RD WH
2
1
3
VMR
BL
24VTR
BLBL
1460
2 3C
460/575TR240
BK OR
BC BLOWER CONTACTOR
PUSEENOTE 3
BC
FS
IGN
BK
VM
OR
RD
L2 L3
C
L2
L3
CMT3
C
FC
T2
T3
T2T1
T1 COMP
L1
CL1
13
3
VMR
BC IIC
VMR
FSIGN
NOTE 3L2
C
RSGV
3
6
PLF 2
5
NOTE 2
1
EM
VM
LS
H CD1
FSF
5
4
L1NOTE 3
ALS
PS
10ECON
3
6
8
12
11
9
IIC
7
TR
FCRDBR
1
4
460-575/3/60 0140L05402-A
LPS HPS
LPS LOW PRESSURE SWITCH
HPS HIGH PRESSURE SWITCH
SMOKE/FIRE DETECTORREPLACES JUMPER WIRE
RD
PK
T2T1
T3
C
BC
BK
BC
BC
RD
OR
HPS
LPS
L1L2
L3
ORBK
WH
ORBKRD
OR
BL
RDY1
YL
W
BL
GR
W
NO ECONOMIZER
G
YL
RD
Y2
Y1
PK
WH
W
R RD
WHGR
C
RYL
GR
Y1
GWH
WITH ECONOMIZER OPTION
C
GR
THERMOSTATFIELD WIRING
BL
C
2 STAGE COOLING
TB1
GR
W
Y
C
TB1
TB1
Y
W
RG
C
W
Y2
GR
C
Y1
STAT
STAT
STAT
BL/PK
YL/PK
BL/PK BLUE WITH PINK STRIPYL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
GR
POWER SUPPLY
SEE NOTE 4
460/3/60575/3/60
575
TO THERMOSTAT
YL BL RDWH
GR
SEENOTE 5
BR
BR
5. FOR LOW STAGE OPERATION ONLY, REMOVE WHITE JUMPER. FOR 2 STAGE OPERATION, REMOVE JUMPER AND CONNECT W2 TO W2 ON THERMOSTAT.
460-575/3/60SUPPLY VOLTAGE
SEE UNIT RATING PLATE FOR TYPE AND SIZEOF OVER CURRENT PROTECTION.
OR
RD
BL
BK
87
9
9 8 7
TO THERMOSTATTERMINAL BLOCK
GR Y1 CGR W1 Y2Y1 CW2S1 S2
Y2Y1S1S2 RC W1 GW2
GR
WH
PU
RD
Y2
Y2
0140
L054
02-A
52 www.daikinac.com SS-DSG3
Wiri
ng i
s su
bjec
t to
cha
nge.
Alw
ays
refe
r to
the
wiri
ng d
iagr
am o
n th
e un
it fo
r th
e m
ost
up-t
o-da
te w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.⚡
Wiring Diagram — DSG(036/060) 090 (4B/7B), DSG0480904B, DSG048115(4B/7B), DSG060140(4B/7B) THREE PHASE 460V/575V BELT DRIVE (cont.)
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
USE NEC CLASS 2 WIRE.4. USE COPPER CONDUCTORS ONLY.
2. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
FALSE FLAMESENSED
OPEN LIMIT SWITCHWITHOUT INDUCER ONPRESSURE SWITCH CLOSED
PRESSURE SWITCH
NORMAL OPERATION
INTERNAL CONTROL
3 BLINKS
6 BLINKS
4 BLINKS5 BLINKS
OUTPUT DELAYCOMPRESSOR
OFF
ON
1 BLINK
2 BLINKS
STATUS LIGHT
OPEN AUX. LIMIT
IGNITION FAILUREOPEN ROLLOUT
SWITCH
OPEN
SWITCH
NO POWER OR
EQUIP. STATUS
CHECK
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVEBAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
GAS PRESSURE
FLAME ROLLOUT
AUX. LIMIT OPEN
FLAME SENSOR
BAD SWITCH
GAS VALVE
REPLACE CONTROLGAS FLOW
PRESSURE SWITCHCHECK
CHECK FUSE ON CONTROLCHECK INPUT POWER
-CHECK
NOTES
TRANSFORMERTR
LOW VOLTAGE
FACTORY WIRING LINE VOLTAGE
LOW VOLTAGE
FIELD WIRING HIGH VOLTAGE
OPTIONAL HIGH VOLTAGE
ALS
COMP
COMPONENT LEGEND
COMPRESSOR
EM
IICIGN
GNDFS
GV
C
F FUSEFC
EVAPORATOR MOTOR
FLAME SENSOREQUIPMENT GROUND
IGNITOR
GAS VALVE
CONTACTOR
FAN CAPACITOR
RSTB1
PLFPS
VMVMR
ROLLOUT SWITCHTERMINAL BLOCK (24V SIGNAL)
PRESSURE SWITCH
VENT MOTORVENT MOTOR RELAY
LIMIT SWITCHLS
CONDENSER MOTORCM
INTEGRATED IGNITION CONTROL
FEMALE PLUG/CONNECTOR
AUXILLARY LIMIT SWITCH
IBR INDOOR BLOWER RELAY
GND
T3
RD
OR
L3
YL
BK
GR
YL
IIC
T1 T2BKPU
YL
BKRD
CL1 L2BL
BL
RD
ORBK
BK
T3 T2 T1
PU
COMP
CM
BR BK
RD
RDLS
WH
GR
1079 12
8 11
ECON
BLPU
RDRD
RD
13
26
54
WH
L1BR
FS
YL
RD
DI
BL
YL
YL
BL
YL
PU
YLPUPS
541
2
NOTE 2PLF
63
YL
RS
ALS
GR
HEATCOOL
UNUSED
BL
BL L2
BL
YL
MV
MV
PU
PU W. R.GAS VALVE
GV
BL
BL
(ALT.) HONEYWELLGAS VALVE
GV
GR
OR
RD
BK
OR
EM
RD WH
2
1
3
VMR
BL
24VTR
BLBL
1460
2 3C
460/575TR240
BK OR
BC BLOWER CONTACTOR
PUSEENOTE 3
BC
FS
IGN
BK
VM
OR
RD
L2 L3
C
L2
L3
CMT3
C
FC
T2
T3
T2T1
T1 COMP
L1
CL1
13
3
VMR
BC IIC
VMR
FSIGN
NOTE 3L2
C
RSGV
3
6
PLF 2
5
NOTE 2
1
EM
VM
LS
H CD1
FSF
5
4
L1NOTE 3
ALS
PS
10ECON
3
6
8
12
11
9
IIC
7
TR
FCRDBR
1
4
460-575/3/60 0140L05402-A
LPS HPS
LPS LOW PRESSURE SWITCH
HPS HIGH PRESSURE SWITCH
SMOKE/FIRE DETECTORREPLACES JUMPER WIRE
RD
PK
T2T1
T3
C
BC
BK
BC
BC
RD
OR
HPS
LPS
L1L2
L3
ORBK
WH
ORBKRD
OR
BL
RDY1
YL
W
BL
GR
W
NO ECONOMIZER
G
YL
RD
Y2
Y1
PK
WH
W
R RD
WHGR
C
RYL
GR
Y1
GWH
WITH ECONOMIZER OPTION
C
GR
THERMOSTATFIELD WIRING
BL
C
2 STAGE COOLING
TB1
GR
W
Y
C
TB1
TB1
Y
W
RG
C
W
Y2
GR
C
Y1
STAT
STAT
STAT
BL/PK
YL/PK
BL/PK BLUE WITH PINK STRIPYL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLEPK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
GR
POWER SUPPLY
SEE NOTE 4
460/3/60575/3/60
575
TO THERMOSTAT
YL BL RDWH
GR
SEENOTE 5
BR
BR
5. FOR LOW STAGE OPERATION ONLY, REMOVE WHITE JUMPER. FOR 2 STAGE OPERATION, REMOVE JUMPER AND CONNECT W2 TO W2 ON THERMOSTAT.
460-575/3/60SUPPLY VOLTAGE
SEE UNIT RATING PLATE FOR TYPE AND SIZEOF OVER CURRENT PROTECTION.
OR
RD
BL
BK
87
9
9 8 7
TO THERMOSTATTERMINAL BLOCK
GR Y1 CGR W1 Y2Y1 CW2S1 S2
Y2Y1S1S2 RC W1 GW2
GR
WH
PU
RD
Y2
Y2
SS-DSG3 www.daikinac.com 53
WIRING DIAGRAMS FOR MODELS WITH DDC CONTROLS ARE LOCATED IN SUPPLEMENT IODS1024*
For complete information and installation instructions for models with DDC controls, see manual DK-DDC-TGD-01*
54 www.daikinac.com SS-DSG3
Accessories
Daikin Master Item # Description Fits Model
SizesField-
InstalledFactory- Installed
Operating Weight (lbs)
Curb14CURB3672B 14” Roof Curb 3-5 Tons √ 86
18CURB3672B 18” Roof Curb 3-5 Tons √ 100
24CURB3672B 24” Roof Curb 3-5 Tons √ 128
GHRC-3672 Hurricane Restraint Clips 3-5 Tons √ 2
Ultra Low-Leak Economizer & Power Exhaust1
10-366-09C Ultra Low-Leak Downflow Economizer w/ Enthalpy 3-5 Tons √ √ 71
10-396-09 Ultra Low-Leak Horizontal Economizer w/ Enthalpy 3-5 Tons √ 71
10-465-09-21 Prop Power Exhaust 230v 3-5 Tons √ 55
10-465-09-31 Prop Power Exhaust 460v 3-5 Tons √ 55
10-465-09-41 Prop Power Exhaust 575v 3-5 Tons √ 55
Low-Leak Economizer & Power Exhaust2
DDNECNJ3672C Low-Leak Downflow Economizer 3-5 Tons √ √ 82
DPE36722 Downflow Power Exhaust (208/230 Volt) 3-5 Tons √ 55
DPE36724 Downflow Power Exhaust (460 Volt) 3-5 Tons √ 55
DPE36727 Downflow Power Exhaust (575v) 3-5 Tons √ 55
DHZECNJ3672 Horizontal Economizer 3-5 Tons √ 70
DHPE36722 Horizontal Power Exhaust (208/230 Volt) 3-5 Tons √ 55
DHPE36724 Horizontal Power Exhaust (460 Volt) 3-5 Tons √ 55
DHPE36727 Horizontal Power Exhaust (575 Volt) 3-5 Tons √ 55
Downflow AccessoriesD25FD3672 25% Manual Fresh Air Damper 3-5 Tons √ 12
D25MFD3672 25% Motorized Fresh Air Damper 3-5 Tons √ 16
DDNBBS3672 Burglar Bar Sleeves with Supply & Return 3-5 Tons √ 30
DDNECNJ3672NR Downflow Economizer2 w/o Barometric Relief 3-5 Tons √ 77
DDNSQRD3616 Downflow Square-to-Round Adapter (16” Round) 3 tons √ 45
DDNSQRD487218 Downflow Square-to-Round Adapter (18” Round) 4-5 tons √ 35
Horizontal AccessoriesDBRD3672 Barometric Relief Damper 3-5 Tons √ 15
ConcentricsCDK36 Concentric Duct Kit 3 Ton √ 27
CDK36515 Flush Mount Concentric Duct Kit w/ Filter 3 Ton √ 28
CDK36530 Step Down Concentric Duct Kit 3 Ton √ 27
CDK36535 Step Down Concentric Duct Kit w/ Filter 3 Ton √ 28
CDK4872 Concentric Duct Kit 4-5 Ton √ 27
CDK4872515 Flush Mount Concentric Duct Kit w/ Filter 4-5 Ton √ 28
CDK4872530 Step Down Concentric Duct Kit 4-5 Ton √ 27
CDK4872535 Step Down Concentric Duct Kit w/ Filter 4-5 Ton √ 28
SS-DSG3 www.daikinac.com 55
Accessories (cont.)
Daikin Master Item # Description Fits Model
SizesField-
InstalledFactory- Installed
Operating Weight (lbs)
DDC Accessories3
DDC communicating controller (built-in BACnet® MS/TP) includes Standard Room Sensor to be installed in field
3-5 Tons √ 2
10366D09C DDC Ultra Low-Leak Downflow Economizer 3-5 Tons √ √ 71
10396D09 DDC Ultra Low-Leak Horizontal Economizer 3-5 Tons √ 71
10465DDCPower Exhaust kit used with DDC Ultra Low-Leak Economizer
3-5 tons √ 1
DLAKT01 Low-Ambient 3-5 Tons √ √ 2
LONKT01 LonWorks® card 3-5 Tons √ 1
3PMK01 Phase Monitor (3-Phase Only) 3-5 Tons √ √ 2
DFSKT01 Dirty Filter Switch 3-5 Tons √ 1
High-Static Kits4
HSKTS036 High Static Kit - 230v & 460v DS*, 3 Ton √ √ 2
HSKTS048 High Static Kit - 230v & 460v DS*, 4 Ton √ √ 38
HSKTS060 High Static Kit - 230v & 460v DS*, 5 Ton √ √ 38
HSKTS036-7 High Static Kit - 575v DS*, 3 Ton √ √ 2
HSKTS048-7 High Static Kit - 575v DS*, 4 Ton √ √ 5
HSKTS060-7 High Static Kit - 575v DS*, 5 Ton √ √ 38
Crankcase Heater Kits0163R00002S 40W 230V 3 tons √ 1
0163R00031S 40W 460V 3 tons √ 1
0163R00032S 40W 575V 3 tons √ 1
0130L00017S 70W 230V 4 - 5 tons √ 1
0130L00018S 70W 460V 4 - 5 tons √ 1
0130L00019S 70W 575V 4 - 5 tons √ 1
High Efficiency Filters
0160L00203High Efficiency MERV 13 Air Filter Nom. Size: 24x24x2; (Order Qty 1)
3 tons √ 2
0160L00204High Efficiency MERV 13 Air Filter Nom. Size: 14x20x2; (Order Qty 4)
4 tons √ 4
0160L00205High Efficiency MERV 13 Air Filter Nom. Size: 16x20x2; (Order Qty 4)
5 tons √ 4
Misc AccessoriesHAILGD03D Condenser Coil Hail Guard 3-4 tons √ 19HAILGD04D Condenser Coil Hail Guard 5 tons √ 19
Convenience Outlet: Non Powered 3-5 tons √ 2
Convenience Outlet: Powered 3-5 tons √ 42
Disconnect Switch 3-5 tons √ 5LAKT11 Low Ambient Kit, 208-230V - non-DDC 3-5 tons √ √ 14
LAKT13 Low Ambient Kit, 460V - non-DDC 3-5 tons √ √ 14
LAKT14 Low Ambient Kit, 575V - non-DDC 3-5 tons √ √ 14
3PMNDK01 Phase Monitor - Non DDC 3-5 Ton √ √ 2
56 www.daikinac.com SS-DSG3
Our continuing commitment to quality products may mean a change in specifications without notice. © 2017 • Houston, Texas • Printed in the USA.
Accessories (cont.)
Daikin Master Item # Description Fits Model
SizesField-
InstalledFactory- Installed
Operating Weight (lbs)
Smoke Detector (supply and/or return air) 3-5 Ton √ 11
Hinged Panels 3-5 Ton √ 10
FSK01A Freeze Stat Kit 3-5 Ton √ 1
IRKT-01 Isolation Relay Kit 3-5 Ton √ 2
LPM-07 LP Conversion Kit (For DSG036045 unit only) 3 Ton √ 1
LPM-08 LP Conversion Kit 3-5 Ton √ 1
220-GX-01 Flue Extension Kit 3-5 Ton √ 2
HA036300 High Altitude Kit 3-5 Ton √ 21 Use Economizer & Power Exhaust listed within Ultra Low-Leak section 2 Use Economizer & Power Exhaust listed within Low-Leak section 3 For a full list of DDC accessories, please refer to DDC Controller Technical Guide manual (DK-DDC-TGD-01B)4 HSKT High-Static Kits are for use with standard single-speed belt-drive units only. Note: Where multiple variations are available, the heaviest combination is listed.
Recommended